Loading...
HomeMy WebLinkAbout2851 LEVANTE ST; ; CB022932; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 12-04-2002 Residential Permit Permit No: CB022932 Building Inspection Request Line (760) 602-2725 Job Address: 2851 LEVANTE ST CBAD Permit Type: RESDNTL Sub Type: RAD Status: ISSUED Parcel No: 2162301400 Lot #: 0 Applied: 09/30/2002 Valuation: $40,170.00 Construction Type: VN Entered By: RMA Occupancy Group: Reference #: Plan Approved: 12/04/2002 # Dwelling Units: 0 Structure Type: Issued: 12/04/2002 Bedrooms: 0 Bathrooms: 0 Inspect Area: Project Title: LUMSDEN RES-390SF ADDITION Orig PC#: Plan Che4 i2104102 0002 01 02 COP 399=67 Applicant: Owner: KK WEST CONTRACTORS LUMSDEN MATTHEW G&TERRY J 2851 LEVANTE ST 1760 VILLAGE RUN NORTH 92024 CARLSBAD CA 92009 8584799798 Total Fees: $597.37 Total Payments To Date: $197.70 Balance Due: $399.67 Building Permit $304J5 '_1 Meter Size Add 'I Building Permit Fee $0.00- Add! Recl. Water Con Fee $0.00 Plan Check $197.70- Meter Fee $0.00 AddI Plan Check Fee / $0.00 SDCWA Fee $0.00 Plan Check Discount ' . $0.00 CFD Payoff Fee ., $0.00 Strong Motion Fee - $4.02--PFF $0.00 Park in Lieu Fee $0.00 PFF (CFD Fund) - $0.00 Park Fee $0.00 License Tax $0.00 LFM Fee $0.00,N License Tax (CFD Fund) L $0.00 Bridge Fee $0 00 Traffic Impact Fee $0.00 Other Bridge Fee $0.00 Traffic lmpact(CFD Fund) $0.00 BTD #2 Fee $0.00 Sidewalk Fee $0.00 BTD #3 Fee ''$0.b0 PLUMBING TOTAL / $41.00 Renewal Fee ELECTRICAL TOTAL $20.00 Add'l Renewal Fee $0.00\\ MECHANICAL TOTAL $30.50 Other Building Fee $0.00 '' Housing Impact Fee $0.00 Pot. Water Con. Fee $0.00 Housing lnLieu Fee $0.00 Meter Size l -R.GFMaster Drainage Fee $0.00 AddI Pot. Water Con. Fee $0.90 Sewer Fee $0.00 Red. Water Con. Fee $0.00 Additional Fees $0.00 TOTAL PERMIT FEES $597.37 - i FINAL APPROVAL ClInspector J-Date: P )- Oy o3 'Clearance: NOTICE: Please take N6E ttpvaI of your project includes the 'Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as 'fees/exactions." p/have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures brth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have Dreviouslv been given p NOTICE similar to this, or as to which the statute of limitations has oreviouslv otherwise exoired. J.itcc PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 • 1 PROJECT INFORMATION FOR OFFICE USE ONLY PLAN CHECK NO.)49 ez EST. VAL. Plan Ck. Deposit ,7O Validated-13v / YAddss (include Bldg/Suite #) - - - LA'6STr Business Name (at this address 'c&/e FM-4IL/go SD(LT 4 Le al Description Lot No. S/&)E Subdivision Name/Number Unit No Phase No. Total # of units 4D-4 I Cf Assessor's Parcel # fOlTlo"J Existing Use 3go Proposed Use _1___ Description of Work SQ. FT. #of Stories # of Bedrooms # of Bathrooms 2. CONTACT PERSON (if different from applicant) - 7406 09/30/02 000201 02 Name Address City State/Zip T&ephone # Fax # - - 3 APPLICANT fl Contractor 0 Agent for Contractor 0 Owner 0 Agent for Owner Name Address City State/Zip Telephone # X'4 -PROPERTY O,y U!SDEJi Jir I1A1&S&+O 7(O(o32.C1(Tho Nane Address City - CA Telephone # 5 CONTRACTOR COMPANY NAME I / (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any Structure, prior to its issuance, also requires the applicant for Such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemp on. Any violatio of Section 7031.5 by any applicant for a permit subjects the applic nt to a civil penalty of not more than five hundred dollars [S500]l. 7E /r /76 Name Address City State/Zip Telephone # State License # /2s77 '7 License Class B' City Business License # /o?/ 33 , '7 Designer Name Address City State/Zip Telephone State License # 6 WORKERS COMPENSATION Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company-7717'" ,'.t't.? Policy No. _¼9 ' '' -&14Expiration Date_________________ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$1001 OR LESS) Ar CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Fail, re- o secleo d ,,ke ' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand ion to the cost of compensation, damages as provided for in Section 3706 of attorney's fees, DATE 7. OWNER-BUILDO DECLARATI I hereby affirm that I am exempt fro the Contractor's License Law for the following reason: o I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 I am exempt under Section Business and Professions Code for this reason: I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES []NO I (have / have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) .to provide the proposed construction (include name / address / phone number / contractors license number(: I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number /type of work): PROPERTY OWNER SIGNATURE DATE COMPLETE TI-uS SECTION FOR NON RESIDENT/AL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES 0 NO lathe facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES 0 NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 8 CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS_________________________________________________ 9. APPLICANT CERTIFICATION I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citi of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not comm nced within. 1 ays from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work S(/APPLICT'S SIGNATURE ed for i of 1 days (Section 106.4.4 Uniform Building Code). ;9r DATE WHITE: File YELLOW: Applicant PINK: Finance 4f17i (((2- EsGil Corporation In Partnership with Government for Building Safety DATE: November 25, 2002 4ZN ANT . JURISDICTION: Carlsbad U REVIEWER U FILE PLAN CHECK NO.: 02-2932 SET: III PROJECT ADDRESS: 2851 Levante St. PROJECT NAME: SFD Addition for Matt & Terry Lumsden LI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. El The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. LI The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Li Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: ate contacted: (by: ) Fax #: Ma Telephone Fax In Person REM)RKS: 1. Each sheet of the structural plans must be signed/sealed by Nick Servin. 2.Revise the note at the rear elevation on sheet 3 to show a valid lCBO approval number for the roofing (the 3-digit number, given doesn't exist). pve~ 4de'1.1 By: Sergio Azuela (by KC) Enclosures: Esgil Corporation D GA 0 MB 0 EJ 0 Pc 11/19/02 .trn tl.dot I (4&tj £w U7x7 121& 9320 Chesapeake Drive, Suite 2 8 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation in Partnership with government for Building Safety DATE: November 13, 2002 JURISDICTION: Carlsbad PLAN CHECK NO.: 02-2932 PROJECT ADDRESS: 2851 Levante St. SET: 11 U AP 0 PLAN REVIEWER U FILE PROJECT NAME: SFD Addition for Matt & Terry Lumsden The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. LI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Kory Krucherberg TEL: (858) 449-5151 . Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Kory Krucherberg Telephone #: (858) 449-5151 Date contacted: I ),&03.-(by: Ic ) Fax #:(-(0) Mail Telephone.' Fax Vn Person REMARKS: The mailing address for the new contact person was not provided. By: Sergio Azuela Enclosures: Esgil Corporation LI GA LI MB EJ LI PC 11/5 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576 Carlsbad 02-2932 II November 13, 2002 RECHECK PLAN CORRECTION LIST JURISDICTION: Carlsbad PROJECT ADDRESS: 2851 Levante St. DATE PLAN RECEIVED BY ESGIL CORPORATION: 11/5 REVIEWED BY: Sergio Azuela FOREWORD (PLEASE READ): PLAN CHECK NO.: 02-2932 SET: II DATE RECHECK COMPLETED: November 13, 2002 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. Please make all corrections on the original tracings and submit two new sets of prints to: ESGIL CORPORATION. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? LJYes UNo Carlsbad 02-2932 II November 13, 2002 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 7. At least 1/2 of the common wall must be open and have an opening not less than 25 sq. ft., nor one tenth of the floor area of the interior room, if light and ventilation is being supplied from an adjacent room. Section 1203.1. a) Clearly show it on plans for the common wall between the existing Living Room and the new proposed Entry; also for the common wall between the existing Dining Room and the new proposed Entry.. I) Minimum open areas required are: 57 SF at Living to Entry and 43 SF at Dining to Entry. Original correction is still applicable. 9. Provide an ICBO # or equal (not ASTM #) for roofing assembly. 15. Please clarify if the 1/2" plywood shall be installed at the roof instead of the 2X6 T&G roof decking. Clearly show it on plans. 17. Interior shear walls were not shown on plans. Original correction is still applicable. For Conventional Light-Frame Construction, buildings shall be provided with exterior and interior braced wall lines. Spacing shall not exceed 34' (25' for Seismic Zone 4 or for wind speeds >80 mph) on center in both directions in each story. Sections 2320.4.2 and 2320.5.1 and Table 23-IV-C-1. Carlsbad 02-2932 II November 13, 2002 18. Interior shear walls were not shown on plans. Original correction is still applicable. Show the following on the plans for the required braced wall panels. If the requirements of braced wall panels in conventional light frame construction are not possible, provide design calculations from a licensed Engineer or Architect. a) Show on the plans the location, length and type of braced wall panel as per UBC Section 2320.11.3 and Table 23-IV-C-1. Braced wall panels shall start at not more than 8' from each end of a braced wall line. Braced wall lines shall be in line or offset from each other by not more than 4 feet. In all Seismic Zones, braced wall panels in one story structures shall be installed at each end and not more than 25' on center along the length of the braced wall line. b) Interior braced wall panels shall extend to the roof or floor diaphragm level. c) Any braced wall panel required by Section 2320.11.3 may be replaced by an alternate braced wall panel. UBC Section 2320.11.4. For alternate braced wall panels in one story buildings, show compliance with the following on the plans: Minimum braced panel length is 2'-8" in width and a maximum height of I 0'-0". Each braced wall panel is sheathed on at least one face with 3/8" plywood sheathing nailed with 8d common or galvanized box nails per 23-Il-B-I and blocked at all plywood edges. A minimum of two anchor bolts installed in accordance with Section1806.6 between hold down devices. An approved hold down device fastened to the foundation and capable of providing an uplift capacity of not less than 1,800 pounds is provided at each panel end. d) Continuous footings shall be provided under interior braced wall lines. See Section 2320.5.6 for possible exceptions. 26. City to place their "soils notice" stamp on the plans. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. EsGil Corporation In Partnership with government for fBui&uing Safety DATE: October 9, 2002 JURISDICTION: Carlsbad PLAN CHECK NO.: 02-2932 SET: I PROJECT ADDRESS: 2851 Levante St. PROJECT NAME: SFD Addition for Matt & Terry Lumsden U APRILICANT JURIS U PLAN REVIEWER U FILE The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: BC Drafting, Attn: Robert Carlin 710 S. Rancho Santa Fe Rd., San Marcos, CA 92069 LII Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Robert Carlin Telephone #: (760) 597-2900 Date contacted: (01C 1w- (by: ) Fax Mail -eIephone.- Fax— In Person LI REMARKS: By: Sergio Azuela Enclosures: Esgil Corporation OGA [:1 MB DEJ El PC 10/01 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576 Carlsbad 02-2932 October 9, 2002 GENERAL PLAN CORRECTION LIST JURISDICTION: Carlsbad PLAN CHECK NO.: 02-2932 PROJECT ADDRESS: 2851 Levante St. DATE PLAN RECEIVED BY DATE REVIEW COMPLETED: ESGIL CORPORATION: 10/01 October 9, 2002 REVIEWED BY: Sergio Azuela FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? UYes L3 No Carlsbad 02-2932 October 9, 2002 1. Please make all corrections on the oriciinal tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 1998 edition of the California Building Code (Title 24), which adopts the 1997 UBC, UMC and UPC and the 1996 NEC. 3. Show locations of permanently wired smoke detectors with battery backup: Inside each bedroom. Centrally located in corridor or area giving access to sleeping rooms. In rooms adjacent to hallways serving bedrooms, when such rooms have a ceiling height 24 inches or more above the ceiling height in the hallway. 4. When the valuation of a room addition or repair exceeds $1,000, or when sleeping rooms are created, smoke detectors shall be provided per the above, except that smoke detectors added at existing construction need only be battery powered. Section 310.9.1.2. 5. Window area must be at least 1/10 of the floor area and a minimum of 10 square feet per Section 1203.3. a) -Clearly show it on plans for the existing Living Room and also for the existing Dining Room. 6. Openable window area in habitable rooms must be 1/20 of the floor area and a minimum of 5 square feet. In bathrooms and water closet compartments, 1/20 of area is required and minimum is 1.5 sq. ft. Section 1203.3. a) Clearly show it on plans for the existing Living Room and also for the existing Dining Room. vl Carlsbad 02-2932 October 9, 2002 7. At least 1/2 of the common wall must be open and have an opening not less than 25 sq. ft., nor one tenth of the floor area of the interior room, if light and ventilation is being supplied from an adjacent room. Section 1203.1. a) Clearly show it on plans for the common wall between the existing Living Room and the new proposed Entry; also for the common wall between the existing Dining Room and the new proposed Entry. 8. Specify roof material and application. Chapter 15. 9. Specify on the plans the following information for the roof materials, per Section 106.3.3: Manufacturer's name. Product name/number. ICBO approval number, or equal. 10. Per local ordinance, a Class "A" roof is required. 11. Show the required ventilation for attics (or enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters). The minimum vent area is 1/150 of attic area (or 1/300 of attic area if at least 50% of the required vent is at least 3 feet above eave vents or cornice vents). Show area required and area provided. Section 1505.3. 12. Where eave vents are installed, insulation shall not block the free flow of air. A minimum of 1" of air space shall be provided between the insulation and the roof sheathing. To accommodate the thickness of insulation plus the required 1" clearance, member sizes may have to be increased for rafter-ceiling joists. Section 1505.3. 13. Note on the plans: "Attic ventilation openings shall be covered with corrosion-resistant metal mesh with mesh openings of 1/4-inch in dimension." Section 1505.3. 14. Note on plans that surface water will drain away from building and show drainage pattern. Section 1804.7. 15. Specify nail size and spacing for roof diaphragm. Indicate required blocking. Maintain maximum diaphragm dimension ratios. Sections 2315 and 2513. 16. Show location of attic access with a minimum size of 22"x30", unless the maximum vertical headroom height in the attic is less than 30". Access must be provided to each separated attic area, shall be located in a hallway or other readily accessible location and 30" headroom clearance is required above the opening. Section 1505.1. 17. For Conventional Light-Frame Construction, buildings shall be provided with exterior and interior braced wall lines. Spacing shall not exceed 34' (25' for Seismic Zone 4 or for wind speeds >80 mph) on center in both directions in each story. Sections 2320.4.2 and 2320.5.1 and Table 23-IV-C-1. Carlsbad 02-2932 October 9, 2002 18. Show the following on the plans for the required braced wall panels. If the requirements of braced wall panels in conventional light frame construction are not possible, provide design calculations from a licensed Engineer or Architect. a) Show on the plans the location, length and type of braced wall panel as per UBC Section 2320.11.3 and Table 23-IV-C-1. Braced wall panels shall start at not more than 8' from each end of a braced wall line. Braced wall lines shall be in line or offset from each other by not more than 4 feet. In all Seismic Zones, braced wall panels in one story structures shall be installed at each end and not more than 25' on center along the length of the braced wall line. b) Interior braced wall panels shall extend to the roof or floor diaphragm level. c) Any braced wall panel required by Section 2320.11.3 may be replaced by an alternate braced wall panel. UBC Section 2320.11.4. For alternate braced wall panels in one story buildings, show compliance with the following on the plans: Minimum braced panel length is 2'-8" in width and a maximum height of 101-011. Each braced wall panel is sheathed on at least one face with 3/8" plywood sheathing nailed with 8d common or galvanized box nails per 23-I1-B-I and blocked at all plywood edges. A minimum of two anchor bolts installed in accordance with Section1806.6 between hold down devices. An approved hold down device fastened to the foundation and capable of providing an uplift capacity of not less than 1,800 pounds is provided at each panel end. d) Continuous footings shall be provided under interior braced wall lines. See Section 2320.5.6 for possible exceptions. 19. Show the location, type and size (BTU's) of all heating and cooling appliances or systems. 20. Show source of combustion air to furnace, per Chapter 7, UMC. Show the location and size of the combustion air openings. 21. Show on the plan the amperage of the electrical service, the location of the service panel and the location of any sub-panels. If service is over 200 amps, submit single line diagram, panel schedule and load calculations. 22. Note on the plans that receptacle outlet locations will comply with NEC Art. 210-52(a). 23. Note on the plans that "Combustion air for fuel burning water heaters will be provided in accordance with UPC Section 507 and Table 5-1". 24. Show T and P valve on water heater and show route of discharge line to exterior. UPC, Section 608.5. Carlsbad 02-2932 October 9, 2002 In Seismic Zones 3 and 4, show that water heater is adequately braced to resist seismic forces. Provide two straps (one strap at top 1/3 of the tank and one strap at bottom 1/3 of the tank). UPC, Section 510.5 City to place their "soils notice" stamp on the plans. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. Carlsbad 02-2932 October 9, 2002 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 02-2932 PREPARED BY: Sergio Azuela DATE: October 9, 2002 BUILDING ADDRESS: 2851 Levante St. SFD Add./ Matt & Terry Lumsden BUILDING OCCUPANCY: R-3 & U-i TYPE OF CONSTRUCTION: V-N BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Dwelling Add. 390 40,170 Air Conditioning Fire Sprinklers TOTAL VALUE 40,170 Jurisdiction Code Icb IBY Ordinance I 1994 UBC Building Permit Fee EEE1 1994 UBC Plan Check Fee V I $304.151 I $197.701 Type of Review: 2 Complete Review E Structural Only 171 Repetitive Fee I Repeats LI Other Hourly __ Hour * Esgil Plan Review Fee I $170.321 Comments: Sheet I of 1 macvalue.doc Citv of Carlsbad 41IFO Public Works - Engineering BUILDING DATE: PLANCHECKNO.: CB 2-93 BUILDING ADDRESS: ~6 PROJECT DESCRIPTION: 3) D ASSESSOR'S PARCEL NUMBER: 1t(0 - 2-'3O i EST. VALUE: ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. LA Right-of-Way permit is required prior to construction of the following improvements: DENIAL Please see the attached report of deficiencies marked with 0. Make necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. By: Date: By: Date: By: Date: FOR OFFICIAL USE ONLY NGINEEfING AUTHORIZATION TO ISSUE BUILDING PERMIT: By: Date: ATTACHMENTS ENGINEERING DEPT. CONTACT PERSON L Dedication Application Name: KATHLEEN M. FARMER 11 Dedication Checklist City of Carlsbad U Improvement Application Address: 1635 Faraday Avenue, Carlsbad, CA 92008 U Improvement Checklist Phone: (760) 602-2741 U Future Improvement Agreement CFD INFORMATION U Grading Permit Application Parcel Map No: U Grading Submittal Checklist Lots: U Right-of-Way Permit Application Recordation: U Right-of-Way Permit Submittal Checklist Carlsbad Tract: and Information Sheet LI Sewer Fee Information Sheet A-4 CA 920081-7314 • (760) 602-2720 • FAX (760) 602R85 to —f7--- City of Carlsbad Bldg Inspection Request For: 06/04/2003 Permit# CB022932 Inspector Assignment: PS Title: LUMSDEN RES-390 SF ADDITION Description: Type: RESDNTL Sub Type: RAD Job Address: 2851 LEVANTE ST Suite: Lot 0 Location: APPLICANT KK WEST CONTRACTORS Owner: LUMSDEN MATTHEW G&TERRY J Remarks: Phone: 8584495151 Inspector: it" I / Total Time: Requested By: CORY Entered By: CHRISTINE CD Description Act Comment 19 Final Structural 4P 7'1 ''' 29 Final Plumbing 39 Final Electrical 49 Final Mechanical I Associated PCRs/CVs Inspection History Date Description Act Insp Comments 05/27/2003 89 Final Combo CA PS BY CORY 02/20/2003 14 Frame/Steel/Bolting/Welding AP PS ENTRY 02/20/2003 16 Insulation AP PS 02/19/2003 14 Frame/Steel/Bolting/Welding CA PS CORY 02/14/2003 15 Roof/Reroof WC PS 02/14/2003 18 Exterior Lath/Drywall WC PS 02/14/2003 84 Rough Combo PA PS OK TO INSULATE 01/28/2003 17 Interior Lath/Drywall AP PS 01/28/2003 18 Exterior Lath/Drywall AP PS 01/24/2003 14 Frame/Steel/Bolting/Welding AP PS 01/24/2003 18 Exterior Lath/Drywall AP PS 01/24/2003 84 Rough Combo AP PS 01/23/2003 13 Shear Panels/1-113's AP PS 01/22/2003 15 Roof/Reroof AP PS 01/22/2003 34 Rough Electric NR PS 01/16/2003 15 Roof/Reroof CA PS BY CORY I BUILDING PLANCHECK CHECKLIST SITE PLAN 1STAND 3RD E /AN ovide a fully dimensioned site plan drawn to scale. Show: rth Arrow ,-FiRight-of-Way Width & Adjacent Streets xisting & Proposed Structures 7 iveway widths ,ø. x-isting Street Improvements ,,HiExisting or proposed sewer lateral / D,/Property Lines I.7Visting or proposed water service Easements 4,—Existing or proposed irrigation service 0 R 2. Show on site plan: A. Drainage Patterns Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building." B. Existing & Proposed Slopes and Topography C. Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project. Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception. D. Sewer and water laterals should not be located within proposed driveways, per / standards. 0 0 3. Include on title sheet: Site address Assessor's Parcel Number Legal Description For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION H:W0R0DOCSCHKLS1BUildkg ftincheck Cidsi Form (Geneflc).doc 2 Rev. 7114/00 BUILDING PLANCHECK CHECKLIST 1S1 2ND 3rd DISCRETIONARY APPROVAL COMPLIANCE El U El 4a. Project does not comply with the following Engineering Conditions of approval for ProjectNo.______________________________________________________ LI 0 El 4b. All conditions are in compliance. Date: DEDICATION REQUIREMENTS El El 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm / drain or utility easements on the building site is required for all new buildings and 7 for remodels with a value at or exceeding $15,000, pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 1/2" x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by: Date: IMPROVEMENT REQUIREMENTS El 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $75,000, pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the H:\WORD\DOCS\CHKLS11Buildui9 Plaflcledc Ckst Form (RIDDLE - HARVEY 7-12.00)4oc 3 Rev. 12/28/ER BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by: Date: F-1 F1 11 6b. Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $310 so we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. Future public improvements required as follows: E 6c. Enclosed please find your Future Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. Future Improvement Agreement completed by: Date: Eli E fl 6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adiacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. El F-1 7a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). EV1E-1 7b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by: Date: 7c. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) H:\WORD\DOCS\CHKLST\Building Plantheck Cklst Form (GENERIC 7-14-00).doc 4 Rev. 7114/00 I BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD E 7d .No Grading Permit required. E 0 7e. If grading is not required, write "No Grading" on plot plan. MISCELLANEOUS PERMITS fl 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. Right-of-Way permit required for: 0 0 0 9. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List. You may telephone (760) 438-2722, extension 7153, for assistance. Industrial Waste permit accepted by: Date: 0 0 M 10. NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit. The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas. Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first. 0 0 11. L Required fees are attached / a-Nfees required WATER METER REVIEW 0 0 0 12a. Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized. Oversized meters are inaccurate during low-flow conditions. If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used. All single family dwelling units received "standard" 1" service with 5/8" service. H:W0RD\D0CSCMKLSTBuildh1g Plantheck clds* Form (Gener,c).doc 5 Rev. 7/14/00 BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm). A typical fixture count and water demand worksheet is attached. Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit. Maximum service and meter size is a 2" service with a 2" meter. If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated demand. (manifolds are considered on case by case basis to limit multiple trenching into the street). 0 0 12b. Irrigation Use (where recycled water is.not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval. The developer must provide these calculations. Please follow these guidelines: If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets. If so, at the water meter station, the demand in gpm may be listed there. Irrigation services are listed with a circled "I", and potable water is typically a circled "W". The irrigation service should look like: STA 1+00 Install 2" service and 1.5: meter (estimated 100 gpm) If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach). Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use. Once you have received a good example of irrigation calculations, keep a set for your reference. In general the calculations will include: Hydraulic grade line Elevation at point of connection (POC) Pressure at POC in pounds per square inch (PSI) Worse case zone (largest, farthest away from valve Total Sprinkler heads listed (with gpm use per head) Include a 10% residual pressure at point of connection 3. In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA). As long as the project is located within the City recycled water H:\W0RDDOCSCHK1Ur PWnd*a Cldst Form (Genenc).doc 6 Rev. 1114100 BUILDING PLANCHECK CHECKLIST 131 2ND 3RD service boundary, the City intends on switching these irrigation services/meters to a new recycled water line in the future. U U 12c. Irrigation Use (where recycled water is available) Recycled water meters are sized the same as the irrigation meter above. If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development. For subdivisions, this should have been identified, and implemented on the improvement plans. Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees. However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge. If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund. However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this. 0 LI 0 13. Additional Comments: H:WORD\DOCSCtKl.ST8Uflg Plancheck Cidsi Form (Geneds).d0C 7 Rev. 7114/00 > C.) a 0 C a) - . a) Q) .c . U o C a) o_ Q. PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST c ~Plys , t Plan Check No. CB ti Y3Z. Address Planner Greg Fisher Phone (760) 602-4629 APN: Type of Proiect & Use:____ Net Project Density: DU/AC Zoning:2. General Plan:2.C1.'_1 Facilities Management Zone: CFD (in/oJt) #_Date of participation: Remaining net dev acres:______ Circle One (For non-residential development: Type of land used created by this permit:________________________________________________ Legend: Z Item Complete E Item Incomplete - Needs your action Environmental Review Required: YES NO TYPE - DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: YES - NO - TYPE APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval:_____________________________________________________ L -e v.4vt ~7'x4 Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES_ NO CA Coastal Commission Authority? YES__ N04 If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): Coastal Permit Determination Form already completed? YES_ NO If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: Follow-Up Actions: Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). Complete Coastal Permit Determination Log as needed. iflIJ 0 lnclusionary Housing Fee required: YES - NO (Effective date of Inclusionary Housing Ordinance - My'4' 1993.) Data Entry Completed? YES NO / (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) H:\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 Site Plan: ! El 1. Provide a fully dimensional site plan drawn to scale. Show: North arrow, 'property lines, easements, existing and proposed structures, streets, existing street improvements, right- of-way width, dimensional setbacks and existing topographical lines (including all side and A rear yard slopes). 1E:1 El 2. Provide legal description of property and assessor's parcel number. Policy 44 - Neighborhood Architectural Design Guidelines t"jJ El 1. Applicability: YES 0_7>!~_ El 2. Project complies YES NO________ Zoning: El El 1. Setbacks: Front: Required Shown " __________ Interior Side: Required Shown 7. 6 Street Side: Required p— Shown Rear: Required / 5. )' Shown - Top of slope: Required Shown . El El 2. Accessory structure setbacks: Front: Required Shown Interior Side: Required Shown Street Side: Required Shown Rear: Required Shown Structure separation: Required Shown IA LIU El 3. Lot Coverage: Required b Shown El El 4. Height: Required 30 Shown El 5. Parking: Spaces Required Z...--- Shown ( (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown El El El Additional Comments___________________________________________________ OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER W1/(ff%JM H:\ADMIN\COUNTER\BIdgPInchkRevChkISt Rev 9/01