HomeMy WebLinkAbout2852 CASTILLA PL; ; CB152035; Permit07-01-2015
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Plumbing/Mechanical/Electrical (PME) Permit
Permit No: CBI 52035
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Reference #:
PC #:
Project Title:
2852 CASTILLA PL CBAD
PME
2162304000 Lot#:
MCGRUE RES- ADD A/C TO PRE
PLUMBED HOME
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
ISSUED
07/01/2015
LSM
07/01/2015
07/01/2015
Applicant:
OAK ISLAND HEATING AND AIR
STE 103
1250 PACIFIC OAKS PL
ESCONDIDO CA 92029
760 839-8383
Owner:
MCGRUE BRIAN&DARLYN
2852 CASTILLA PL
CARLSBAD CA 92009
Plumbing Fees
Electrical Fees
Mechanical Fees
Other PME Fees
$0.00
$0.00
$160.00
$0.00
TOTAL PERMIT FEES $160.00
Total Fees: $160.00 Total Payments To Date: $160.00 Balance Due: $0.00
Inspector: .ML FINAL APPROVAL
Date: //t'l/ Clearance:
NOTICE: Please take NOTICE that approval of your project includes the 'Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this pennit was issued to protest imposition of these fees/exactions. If you protest them, you must
follovK the protest procedures set forth in Govemment Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030, Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which vou have oreviouslv been given a NOTICE similar to this, or as to which the statute of limitations has previouslv othenft>ise expired.
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMmSSUANCE: • PLANNING nENGINEERING nBUILDING DFIRE • HEALTH • HAZMAT/APCD
^ CITY OF
CARLSBAD
Building Permit Appiication
1635 Faraday Ave., Carlsbad, CA 92008
Ph: 760-602-2719 Fax: 760-602-8558
email: building@carlsbadca.gov
www.carlsbadca.gov
Plan Check No. (5" J^Q 3^
Est. Value
Plan Ck. Deposit
Date 1 SWPPP
JOBADDRESS 2852 CASTILLA PL. surTE*/SPACE#/uNrr«
216 230 - 40 - 00
CT/PROJECT # PHASE # # OF UNnS # BEDROOMS # BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE OCC. GROUP
OESCRIPTION OF WORK: Include Square Feet of Affected Araa<s)
ADD 1 NEW A/C UNiT TO AN A/C PREPPED HOME,
NO ELECTRICAL
EXISTING USE PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS (SF) RREPLACE
YES riff NOj I
AIR CONDITIONING
YES I |NO| I
FIRE SPRINKLERS
YES I |NO| I
APPLICANTNAME
Prtnarv Contact TOM WOOD PROPERTY OWNER NAME BRIAN McGRUE
ADDRESS 1250 PACIFIC OAKS PL #103
ADDRESS
2852 CASTILLA PL.
CITY ESCONDIDO STATE
CA
ZIP
92029
CITY CARLSBAD STATE CA ZIP 92009
PHONE
760 839-8383
FAX PHONE
760 839-8380 858-337-2076
FAX
EMAIL INF0@0AKISLANDAC.COM EMAIL
DESIGN PROFESSIONAL CONTRACTOR BUS. NAME OAK ISLAND HEATING AND AIR
ADDRESS ADDRESS 1250 PACIFIC OAKS PL #103
CITY STATE ZIP CITY ESCONDIDO
STATE ZIP
CA 92029
PHONE FAX PHONE
760 839-8383
FAX
760 839-8380
EMAIL EMAIL INF0@0AKISLANDAC.COM
745400 C-20
CITV BUS. LIC.#
1212710
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicantfor such permit to file a signed statement that he is licensed pursuantto the provisions ofthe Contraotor's License Law (Chapter 9, commendingwith Section 7000 of Division 3 of the Business and Professions Code) or that fie is exempt ttierefrom, andthe basis for ttie alleged exemption. Any violation of Section 7031.5 by any applicantfor a permit subjects tfie applicant to a civil penalty of not more than five hundred dollars ($500)).
W OR K E R S ' COMPENSATION
Workers' Compensation Declaration: I hereby affimt under penalty ofpeijury one of fte fbMovwng declarations:
fj I have and will maintain a certificate of consent to self-Insure fbr workers' compensation as provided by Section 3700 of the Labor Code, for the perfbnnance of the wori( for which this pennit is issued.
bu I have and will maintain workers' compensation, as required by Sectkin 3700 of the Labor Code, fbr the perfonnance of the work for which this pemiit is issued. My wodsers' compensatton insurance canier and policy
numiier are: Insurance Ca_ EVEREST NATIONAL INSURANCE PolicyNo.. 7600000635141 Expiratton Date _ 01(0112016
Tlijs sectton need not be connpleted if the pemiit is for one hundred dollars ($t 00) or less.
LJ Certificate of Exemption: I certify that in the peribmiance of the work for which this pemiit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
Califomia. WARNING: Failure to secure workers' compensation coverage is unlawful, and nail subject an employer to criminal penalties and civil flnes up to one hundred thousand dollars (&100,000), in
addition to the cost of compensatian, damages as prjiiiKled for in Section 3706 of the Labor cade, interest and attomey's fees.
jgS" CONTRACTOR SIGNATURE ^^0>V7 (//TJTl-'Cf [7] AGENT DATE
/ hereby affinn that I am exempt (hjm Contractor's Ucense Law for the follcmng reason:
pn I, as owner of the property or my emptoyees with wages as their sole compensation, will do the wori< and the stnjcture is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
— Ltoense Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provkled that such improvements are not intended or offered for
sate. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not buiki or improve for the purpose of sale).
j j I, as owner of the praperty, am exclusively contracting with licensed contractors to constract the project (Sec. 7044, Business and Professions Code: The (iintractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor{s) licensed pursuant to the Contractor's License Law).
• I am exempt under Section _ __Buslness and Professions Code for this reason:
1.1 personally plan to provide the major labor and materials for constmctton of the proposed property improvement. Yes I INO
2.1 (have / have not) signed an applicatton fora buikling pennit for the proposed wori<.
3.1 have contracted v«th the foltowing person (finn) to provide the proposed constmction (include name address / phone / contractors' license number):
4.1 plan to provide porttons of the wori(, but I have hired the following person to coordinate, supenise and provtoe the major wori( (include name / address / phone / contractors' license number):
5.1 will provide some of the wortt, but I have contracted (hired) the foltowing persons to pravide the i«ori( indicated (include name / address / phone / type of vwxk):
^efpROPERTY OWNER SIGNATURE •AGENT DATE
COMPLETE THIS SECTION F\on N O N - R E S t D E N T IA L B U 1 L O I N G P E R M I T S ONLY
Is the applicant or future buikling occupant required fo submit a business plan, acutely hazardous materials legistration forni or risk management and prevention program under Seclions 25505,25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? DYes ONo
Is the applicant or future buikling occupant required fo obtain a pemilt from the air pollutton control district or air quality management district? D Yes • No
Is the Milyfo be constmcted within 1,000 feet of the outer boundaiy of a school site? nYes ONo
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT
CONSTRUCTION LENOING AGENCY
I hereby aflirm that there is a construction lending agency fbr the performance of the work this permit is issued (Sec. 3097 (I) Civil Code).
Lender'sName Lender's Address
A P PLI CANT CERTIFICATIOri^
I ceiti^ttiatl have lead the applicatkm and state that the ab(»e lnk>miatkm
I heieby auihorize representative of Ihe City of Carisbad to enter upon Ihe above mentioned pnoperty for inspectbn purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMff.
OSHA An OSHA pemnit is required for excavations over S'O' deep and demolitbn or constmctbn of structures over 3 stories in heighL
EXPIRATION: Every permit i^ued by the Building Oflicial under the provisions of Ihis Code shall expire by limitatbn and become nuH and void if the building or work aulhorized by such pemiit is not commenced wlhin
180 days hm the date of such pennit or if the building or v«xk authorized by such pennit is suspended or abandoned at any time after the vrorit is commenced for a period of 180 days (Sectbn 106.4.4 Unifomn Building Oxie).
vefAPPUCANT'S SIGNATURE y^^Q^ XXfO^S^ DATE
Inspection List
Permlt#: CB152035 Type: PME MCGRUE RES-ADD A/C TO PRE
PLUMBED HOME
Date Inspection Item Inspector Act Comments
09/11/2015 43 AirCond/Furnace Set - Rl AM PLEASE
09/11/2015 43 AirCond/Furnace Set AEK AP
09/11/2015 49 FinalMechanical - Rl AM PLEASE
09/11/2015 49 FinalMechanical AEK Fl
Monday, September 14, 2015 Page 1 of 1
CERTIFICATE OF COMPUANCE CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC) (Page lof 3)
Project Name: McGRUE RESIDENCE Date Prepared: 2015-06-30
A. General Informatton
CFlR-ALT-02 Is appiicable to multiple space conditioning systems contained witliin a single dwelling unit. When multiple dwelling units must be
documented, use one CFlR-ALT-02 document fbr each dwelling unit.
01 Project Name McGRUE RESIDENCE 02 Date Prepared 2015-06-30
03 Project Location 2852 CASTILLA PL 04 Building Type Single family
05 CACity Carlsbad 06 Dwelling Unit Name McGRUE RESIDENCE
07 Zip Code 92009 08 Dwelling Unit Conditioned
Floor Area (ft2) 1844
09 Climate Zone 7 10
Number of space conditioning
(SC) systems in this dwelling
unit.
1
B. Space Conditk>ning (SC) System Infbrmation
01 02 03 04 05 06 07 08 09 10
SC System
Identification or
Name
SC System
Location or Area
Served
CFA served
by this SC
System (ft2)
Is these
system a
ducted
system?
installing a
refrigerant
containing
component?
Installing new SC
system
components?
Installing
more than 40
feet of ducts?
installing
entirely new
duct system?
Installing
entirely new
SC system? Alteration Type
System 1 Location 1 1844 Yes Yes No No No No Altered space
conditioning system
C. Extension of Existing Duct System, Greater Than 40 Feet (Sectionl50.2(b)lDiib)
This section does not apply to this project.
Registration Nurriber: 215-A0177793A-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration DateAime: 2015-06-30 11:54:14
Report Version: 2014-03-31
Schema Version: O.SSSSDD
HERS Provider: CalCERTS
Report Generated: 2015-06-30 11:54:33
CERTIFICATE OF COMPUANCE CF1R-ALT-02-E
Alterations to Space Conditioning Systems (fonnerly CF-IR-ALT-HVAC) (Page 2 of 3)
D. Altered Space Conditioning System (Sections 150.2(b)lE and F)
01 02 03 04 05 06 07 08 09 10 11 12
Heating Cooiing
System Heating Altered Heating Minimum Altered Cooling Minimum Required New or
Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct
or Name Type Components Type Value System Type Components Type Value Type Duct Length R-Value
System 1 Central gas
furnace
No heating
component
altered
This field or
section Is not
applicable
This field or
section is not
applicable
Central split
AC
Outdoor
condensing
unit
SEER 14 Setback
Less than or
equal to 40
feet
R-6
Required Documetrtatton:
CF2R-MCH-01-E - Space Conditioning Systems Ducts and Fans
-Duct insulation requirement fbr new plenums: RS.
CF2R-MCH-20-H & CF3R-MCH-20-H - Duct Leakage testing required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced.
-Leakage rate compliance: i 15%, or S10% leakage to outside, or seal all accessible teaks.
CF2R-MCH-25-H & CF3R-MCH-25-H Refr^erant Charge Verification required when refrigerant containing components are installed or altered (applicable in CZ 2,8-15).
CF2RCF3R-MCH-23 & CF3R-MCH-23 Air Flow i 300 CFIVl/ton required when iyiCH-25 is required.
Eweption;;
-Duct systems registered with HERS provider as previously sealed are exempt from MCH-20 Duct Leakage Testing requirements.
-Heating-only systems and Air Handler/Furnace changes do not require veriflcation of Air Flow MCH-23, or Refrigerant Charge MECH-25.
-Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH-20 Duct Leakage Testing requirements.
E. Entirely New or Compiete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)lDiia and 150.2(b)lE, F)
This section does not apply to this project.
F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)lC)
This section does not apply to this project.
Registration Number: 215-A0177793A-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residentiai Compliance
Registration Date/Time: 2015-06-30 11:54:14
Report Version: 2014-03-31
Schema Version: 0.555S0D
HERS Provider: CalCERTS
Report Generated: 2015-06-30 11:54:33
CERTIFICATE OF COMPLiANCE CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC) (Page 3 of 3)
Documentation Author's Declaration Statement
1.1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Young, Les
Documentation Author Signature:
Company:
OAK ISUND HEATING AND AIR CONDITIONING INC
Signature Date:
2015-06-30 11:54:14
Address:
1250 PACIFIC OAKS PL # 103
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
ESCONDIDO CA 92029
Phone:
(760) 839-8383
Responsible Person's Declaration statement
1 certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer).
3. That the energy features and performance specificattons, materials, components, and manufectured devices for the building design or system design identified on this Certificate of Compliance conform to the
requirements of Title 24, Part 1 and Part 6 of the Califomia Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency fbr approval with this building permit application.
5. 1 will ensure that a registered copy of this Certificate of Compliance shall be made available with ttie building permit(s) issued for the buiiding, and made available to the enforcement agency for all applicable
inspections. 1 understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy.
Responsible Designer Name:
Young, Les
Responsible Designer Signature: ^^i^
Company:
OAK ISUND HEATING AND AIR CONDiTlONING INC
Date Signed:
2015-06-3011:54:14
Address:
1250 PACIFIC OAKS PL # 103
License:
745400
aty/State/Zip:
ESCONDIDO CA 92029
Phone:
(760) 839-8383
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document and in no way implies Registration Provider responsibility for the accuracy ofthe information.
Registration Number: 215-A0177793A-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2015-06-3011:54:14
Report Version: 2014-03-31
Schema Version: O.SSSSDD
HERS Provider: CalCERTS
Report Generated: 2015-06-30 11:54:33
' 0 0 0 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 1 of 7)
Project Name: McGRUE RESIDENCE Enforcement Agency: City of Carlsbad Permit Number: on site
Dwelling Address: 2852 CASTILU PL. City: Carlsbad Zip Code: 92009
A. General Information
01 Dwelling Unit Name McGRUE RESIDENCE 02 Climate Zone 7
03 Dwelling Unit Conditioned Floor Area
(ft2) 1844 04
Number of space conditioning (SC)
systems being altered in this dwelling
unit.
1
05 Certificate of Compliance Type Prescriptive alterations (CFIR-ALT) 06 Method used to calculate HVAC loads NotApplicableEquipmentChangeout
07 Calculated dwelling unit Sensible
Cooling Load (Btuh) This field or section is not applicable 08 Calculated Dwelling Unit Heating Load
(Btuh) This field or section is not applicable
MCH-Olb Prescriptive Alterations - Space Conditioning Systems Ducts and Fans
B. Space Conditioning (SC) System Information
01 02 03 04 05 06 07 08 09 10
SC System
Identification or
Name
SC System
Location or Area
Served
CFA served
by this SC
System
(ft2)
Is the SC
system a
ducted
system?
Installing a
refrigerant
containing
component?
installing new SC
system
components?
Installing more
than 40 feet of
ducts?
Installing
entirely
new duct
system?
Installing
entirely new
SC system? Alteration Type
System 1 Location 1 1844 Yes Yes Yes No No No
Altered space
conditioning
system
Registration Number: 215-A0177793A-M0100002A-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2015-07-23 17:39:52
Report Version: 2014-05-13
Schema Version: O.SSSSDD
HERS Provider: CalCERTS
Report Generated: 2015-07-23 16:58:07
CERTIFICATE OF INSTALUTION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 2 of 7)
C. Space Conditioning (SC) System Alterations Compliance information
01 02 03 04 OS 06 07 08 09 10 11 12 13
System
Identification
or Name
Heating
System Type
Altered
Heating
Component
Heating
Efficiency
Type
Heating
Minimum
Efficiency
Value
Cooling
System Type
Altered
Cooling
Component
Cooling
Efficiency
Type
Cooling
Minimum
Efficiency
Value
Required
Thermostat
Type
New or
Replaced
Duct
Length
New
Duct
R-Value
Central Fan
Integrated
(CFI)
Ventilation
System
Status
System 1 Central gas
furnace
No heating
componen
t altered
This field
or
section is
not
applicabi
e
This field
or section
is not
applicable
Central
split AC
All new
cooling
components
SEER 14 Setback LTE40Ft R6 Not a CFI
system
D. Installed Heating Equipment information
This section does not apply to this project.
E. Installed Cooling Equipment information:
01 02 03 04 05 06 07 08
Condenser or Package Unit
System Identification
or Name
Cooling Efficiency
Type
Cooling Efficiency
Value
Condenser or
Paclcage Unit
Manufacturer
Condenser or
Package Unit
Model Number
Condenser or
Package Unit
Serial Number
System Rated Cooling
Capacity at Design
Conditions (BTUH)
Condenser Rated
Nominal Capacity
(ton)
System 1 SEER 16 Lennox XC16-036-230-
a5 5815e08910 36000 3
Notes:
Registration Number: 215-A0177793A-M0100002A-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2015-07-23 17:39:52
Report Version: 2014-05-13
Schema Version: O.SSSSDD
HERS Provider: CalCERTS
Report Generated: 2015-07-23 16:58:07
CERTiFICATE OF INSTALUTION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 3 of 7 )
F. Extension of Existing Duct System, Greater Than 40 Feet
G. Installed Duct System information
This section does not apply to this project.
H. Installed Air Filter Device Information
This section does not apply to this project.
I. Air Filter Device Requirements
This section does not apply to this project.
This section does not apply to this project.
Registration Number: 215-A0177793A-M0100002A-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2015-07-23 17:39:52
Report Version: 2014-05-13
Schema Version: 0.555SDD
HERS Provider: CalCERTS
Report Generated: 2015-07-23 16:58:07
CERTiFICATE OF INSTALUTION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 4 of 7 )
J. HERS Verification Requirements
01 02 03 04 05 06 07 08 09 10
MCH20 MCH21 MCH22 MCH23 MCH25 MCH28
SC System
identification or
Name
SC System
Location or Area
Served
Exemption
From Duct
Leakage
Requirements
Duct
Leakage
Test
Exemption
from
Minimum
R-Value for
Ducts in
Conditioned
Space
Ducts Located
in Cond Space
Verification
AHU Fan
Efficacy
(W per
cfm)
AHU
Airflow
Rate (cfm
per ton)
Refrigerant
Charge
Return Duct Design
Table 150.0-C or D
System 1 Location 1 No
exemptions Yes Not
applicable No No No No No
Registration Number: 215-A0177793A-M0100002A-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2015-07-23 17:39:52
Report Version: 2014-05-13
Schema Version: O.SSSSDD
HERS Provider: CalCERTS
Report Generated: 2015-07-23 16:58:07
CERTIFiCATE OF INSTALUTION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 5 of 7 )
K. Space Conditioning Systems, Ducts and Fans IVIandatory Requirements and Additional Measures
Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly Installed equipment or portions of the
system that are altered. Existing equipment may be exempt from these requirements.
Heating Equipment
01 Equipment Efficiency: All heating equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency
Regulations.
02 Controls: All unitary heating systems, including heat pumps, must be controlled by a setback thermostat. These thermostats must be capable of allowing the occupant
to program the temperature set points for at least four different periods in 24 hours. See Sections 150.0(1), 110.2(b).
03 Sizing: Heating load calculations must be done on portions ofthe building served by new heating systems to prevent inadvertent undersizing or oversizing. See sections
150.0(h)land 2).
04 Furnace Temperature Rise: Central forced-air heating furnace installations must be configured to operate at or below the furnace manufacturer's maximum
inlet-to-outlet temperature rise specification. See Section 150.0(h)4.
05 Standby Losses and Pilot Lights: Fan-type central furnaces may not have a continuously burning pilot light. Section 110.5 and Section 110.2(d).
Cooling Equipment
06 Equipment Efficiency: All cooling equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency
Regulations.
07 Refrigerant Line Insulation: All refrigerant line insulation in split system air conditioners and heat pumps must meet the R-value and protection requirements of Section
150.0(j)2 and 3, and Section 150.0(m)9.
08 Condensing Unit Location: Condensing units shall not be placed within five (5) feet of a dryer vent outlet. See Section 150.0(h)3A.
09 Sizing: Cooling load calculations must be done on portions ofthe building served by new cooling systems to prevent inadvertent undersizing or oversizing. See Section
150.0(h)l and 2.
Air Distribution System Ducts, Plenums and Fans
10 Insulation: In all cases, unless ducts are enclosed entirely in directly conditioned space, the minimum duct insulation value is R-6. Note that higher values may be
required by the prescriptive or performance requirements. See Section 150.0(m)l.
Registration Number: 215-A0177793A-M0100002A-0000 Registration Date/Time: 2015-07-23 17:39:52 HERS Provider: CalCERTS
CA Buildmg Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-05-13 Report Generated: 2015-07-23 16:58:07
Schema Version: 0.555SDD
CERTIFiCATE OF INSTALUTION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 6 of 7 )
K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures
Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly Installed equipment or portions of the
system that are altered. Existing equipment may be exempt from these requirements.
11
Connections and Closures: All installed air-distribution system ducts and plenums must be, sealed and insulated to meet the requirements of CMC Sections 601.0,
602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006: Supply-air and return-air ducts and plenums must be insulated to a minimum installed level of R-6.0 or
enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing in accordance with the requirements of Reference
Residential Appendix RA3.1.4.3.8.
Heat Pump Thermostat
12 A thermostat shall be installed that meets the requirements of Section 110.2(b) and Section 110.2(c).
13 The thermostat shall be installed in accordance with the manufacturers published installation specifications
14 First stage of heating shall be assigned to heat pump heating.
15 Second stage back up heating shall be set to come on only when the indoor set temperature cannot be met.
The responsible person signature on this compliance document affirms that all applicabie requirements in this table have been met.
Registration Number: 215-A0177793A-M0100002A-0000 Registration DateAime: 2015-07-23 17:39:52 HERS Provider: CalCERTS
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-05-13 Report Generated: 2015-07-23 16:58:07
Schema Version: O.SSSSDD
CERTIFICATE OF INSTALUTION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 7 of 7)
Documentation Author's Declaration Statement
1.1 certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Young, Les
Documentation Author signature: _ _ .
Company:
OAK ISUND HEATING AND AIR CONDITIONING INC
Signature Date:
2015-07-23 17:39:52
Address:
1250 PACIFIC OAKS PL #103
CEA/ HERS Certification Identification (if applicable);
City/state/zip:
ESCONDIDOCA 92029
Phone:
(760) 839-8383
Responsible Person's Declaration statement
1 certify the following under penalty of perjury, underthe laws of the State of California:
1. The Information provided on this Certificate of Installation is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials,
components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement (responsible builder/installer), otherwise 1 am an
authorized representative ofthe responsible builder/installer
3. The constructed or Installed features, materials, components or manufactured devices (the Installation) identified on this Certificate of Installation conforms to all applicable codes and regulations, and the
installation conforms to the requirements given on the plans and specifications approved by the enforcement agency.
4. 1 reviewed a copy of the Certificate of Compilance approved by the enforcement agency that identifies the specific requirements for the scope of construction or installation identified on this Certificate of
Installation, and 1 have ensured that the requirements that apply to the construction or installation have been met.
5. 1 will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available tothe enforcement agency for all
applicable inspections. 1 understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy.
Responsible Builder/Installer Name:
Young, Les
Responsible Builder/Installer Signature: _
Company Name: (Installing Subcontractor or General Contractor or Builder/Owner)
OAK ISUND HEATING AND AIR CONDITIONING INC
Position With Company (Title):
MGR
Address:
1250 PACIFIC OAKS PL #103
CSLB License:
745400
City/State/Zip:
ESCONDIDO CA 92029
Phone: Date Signed:
(760)839-8383 2015-07-23 17:39:52
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 215-A0177793A-M0100002A-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration DateAime: 2015-07-23 17:39:52
Report Version: 2014-05-13
Schema Version: O.SSSSDD
HERS Provider: CalCERTS
Report Generated: 2015-07-23 16:58:07