Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2864 WHIPTAIL LOOP; ; PC2016-0038; Permit
rcity of Carlsbad Print Date: 06/21/2019 Permit No: PC2016-0038 Job Address: 2864 Whiptail Loop Permit Type: BLDG-Plan Check Parcel No: 10j %.O VDQ Valuation: $0.00 Occupancy Group: # Dwelling Units: Bedrooms: Work Class: Commercial Lot #:' Reference #: Construction Type Bathrooms:. ( C) 09% Plan Check #: Status: Closed - Finaled Applied: 12/20/2016 Issued: 03/09/2017. Permit 04/03/2018 Finaled: Inspector: Final Inspection: Project Title: Description: ELEVATE: 5 OFFICE/WAREHOUSE SPEC SUITES (100, 103, 104, 109) Lo qRofoorlj Applicant: Owner: Contractor: WARE MALCOMB ARCHITECTS A P G CARLSBAD I LLC TFW CONSTRUCTION DEVELOPMENT INC LISA SMITH 6363 Greenwich Dr 1010 Coast Highway 101 5 C/O Raf Pacifica P0 Box 220 San Diego, CA 92122-5947 Group (SlConb), 103 DEL MAR, CA 92014 619-829-2988 ENCINITAS, CA 92024 858-759-1223 FEE AMOUNT FIRE S Occupancies < 50,000sq. ft. TI $362.00 MANUAL BUILDING PERMIT FEE $2,565.74 Total Fees: $ 2,927.74 Total Payments To Date: $ 2,927.74 Balance Due: $0.00 Building Division 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-2700 1 760-602-8560 f I www.carlsbadca.gov ITHE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: EIPLANNING EJENGINEERING EIBUILDING DFIRE HEALTH EJHAZMATIAPCD Building Permit Application C—city Plan Check No.R t' i,_cO 1635 of Faraday Ave., Carlsbad, CA 92008 Est. Value Ph: 760-602-2719 Fax: 760-602-8558 Cdisbad Plan Ck. Deposit email: building©carlsbadca.gov 1 Date 12-2-0-110 IswpPP I www.carlsbadca.gov JOB ADDRESS 4 kiI4/ LID 60 I SUITE#/SPACE#/UNIT# PN ,/.20 - /0 - ,T/PROJECT A J LOT A PHASE # I# OF UNITS BEDROOMS U BATHROOM S TENANT BUSINESS NAME CONSTR. TYPE 0CC. GROUP DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) Ye,iad fravemeiit in . &iYe )jauSe.. oPf,ce. /63 c q. 99 7/ orcsi '5I LH 4eW0S zt*1-t J1 tih EXISTING USE PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS (SF) I FIREPLACE I AIR CONDITIONING FIRE SPRINKLERS E YES#, NO YES (]NO [J I YES NO[—] APPLICANT NAME L/5t 51fl,,11._. PROPERTY OWNER NAME RAF jac'/ia & rosy2 Primary Contact ADDRESS 6363 (Vee/1A)hsC/' Pr. ADDRESS ,17 0,W f-5 5e,jfi .F p STATE ZIP CITY cfq 92 /22 CITY STA 71P E/1CI"/7'45 PHONE 519- FAX PHONE 76 '/73-B838 I FAX 76o-q96 - .2$ £'71 7 EMAIL EMAIL DESIGN PROFESSIONAL CONTRACTOR BUS. NAME TBA.) C etco,u ADDRESS ADDRESS 7410,UiS(Cw V4E 2oo CITY STATE ZIP CITY STATE ZIP wo PHONE FAX . PHONE (ptq )ft'gf FAX I (,(c' zzo q-tss EMAIL . EMAIL CO#)5?Euci?&. STATE LIC. U STATE UC.0 I I CITY BUS. LIC.# I 2I 27 ec ,u.J..o ousiness ana rroressrons Uoae: Any LIty or county wnicn requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law IChapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). (2)®W(@3 Workers' Compensation Declaration: I hereby affirm under penalty of perjurjr one of the following declarations: R I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. have and will maintain workers' compensatlon,,g.quired by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co. 1! 't"t'(.4J') Policy No. Expiration Dale This section need not be completed if the permit is for one hundred dollars ($100) or less. [J Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, darpages as provided for in Section 3106 of the Labor code, interest and attorney's fees. CONTRACTOR SIGNATURE 77) 0 AGENT DATE ®9)@)00l1iD AO' I hereby affirm that! am exempt from Contractor's License Law for the following reason: [J I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply loan owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). [] I am exempt under Section Business and professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the proposed property Improvement [Yes Dwo 2.1 (have! have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address! phone! contractors' license number): 4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name! address! phone /contractors' license number): 5. I will provide some of the work, butt have contracted (hired) the following persons to provide the work Indicated (include name / address! phone / type of work): ,.PROPERTY OWNER SIGNATURE []AGENT DATE ______ 'O® •0®?0 •O !> (P@1i?G!i)OV ®I)ft Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Yes ,No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Yes No Is the facility lobe constructed within 1,000 feet of the outer boundary of a school site? Yes No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lenders Name Lender's Address 0(1is(1U 00709 I certifythatl have read the application and state thatthe above Information is conectand thatthe information on the plans Is accurate. I agree to complywith all City ordinances and State laws relatingto building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 50' deep and demolition or construction of structures over 3 stories in height EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become nut and void if the building or work authorized by such permit is not commenced within 180 days hem the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced bra period of 180 days (Section 1 06A Uniform Building Code). ..APPLICANT'S SIGNATURE DATE DATE — 2 C STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. aa •FICATE OF OCCUPANCY (Co m mercia l-Proj ects. Fax (760) 602-8560, Email buiIdina(ãcarIsbadca.gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. CO#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE FAX EMAIL OCCUPANT'S BUS. LIC. No. DELIVERY OPTIONS PICK UP: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On pg. 1) MAIL TO: I CONTACT (Listed above) OCCUPANT (Listed above) ASSOCIATED CB#_________________________ CONTRACTOR (On Pg. 1) NO CHANGE IN USE/ NO CONSTRUCTION MAIL! FAX TO OTHER: CHANGE OF USE / NO CONSTRUCTION £'APPLICANT'S SIGNATURE DATE EsGil Corporation In Partnersfiip wit/I government forui&(ing Safety DATE: 2/21/17 U APPLICANT '1URIS. JURISDICTION: cCarisbadii U PLAN REVIEWER U FILE PLAN CHECK NO.: CBpc2016-0038 SET: II PROJECT ADDRESS: 2864 Whiptail Loop #100/3/4/5/9 PROJECT NAME: Spec TI for Suites 100,1039 1049 105 & 109 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. El The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. El The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contactedC Date contacted: • Mail Telephone Fax LI REMARKS: Email: Telephone #: ç9 (S In Person By: Chuck Mendenhall Enclosures: EsGil Corporation GA LJEJDMB 0 PC 2/15/17 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In Partners flip with government for Bui(Iing Safety DATE: 1/3/17 JURISDICTION: Carlsbad PLAN CHECK NO.: PC2016-0038 U APPLICANT ,JURIS. U PLAN REVIEWER U FILE SET:I PROJECT ADDRESS: 2864 Whiptail Loop #100/3/4/5/9 PROJECT NAME: Spec TI for Suites 102, 106, 107 & 108 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Lisa Smith, Ware-Malcomb e-mail LI EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: 1Lisa smith Date contacted: LJ/ Email Fax In Person 06 __111Qn LI REMARKS: By: Chuck Mendenhall EsGil Corporation [I GA DEJDMB El PC Telephone #: (619) 564-5126 lsmith@waremalcomb.com Enclosures: 12/22/16 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad PC20 16-0038 1/3/17 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: PC2016-0038 JURISDICTION: Carlsbad OCCUPANCY: B,S1 USE: Spec Office & warehouse TYPE OF CONSTRUCTION: III B ACTUAL AREA: 4909 sq ft TI Only ALLOWABLE FLOOR AREA: 27,000 sf STORIES: one HEIGHT: no change SPRINKLERS?: Yes REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 1/3/17 FOREWORD (PLEASE READ): OCCUPANT LOAD: 25 max DATE PLANS RECEIVED BY ESGIL CORPORATION: 12/22/16 PLAN REVIEWER: Chuck Mendenhall This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2013 CBC, which adopts the 2012 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2012 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad PC2016-0038 1/3/17 [DO NOT PAY— THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: PC2016-0038 PREPARED BY: Chuck Mendenhall DATE: 1/3/17 BUILDING ADDRESS: 2864 Whiptail Loop #100/3/4/5/9 BUILDING OCCUPANCY: B, Si BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Office TI 5363 46.51 249,433 Air Conditioning Fire Sprinklers TOTAL VALUE I j 249,433 Junsdictbn Code Icb IBY Ordinance Bldg. Permit Fee by Ordinance I $1,158.561 Plan Check Fee by Ordinance IV I $753.061 Type of Review: Iii Complete Review 0 Structural Only [:]Repetitive Fee Repeats D Other Hourly EsGil Fee Hr. @ * $648.791 Comments: In addition to the above fee, an additional fee of $43.00 is due (1/2 hour@ $86/hr.) for the CalGreen review. Sheet of 1 macvalue.doc + Carlsbad PC20 16-0038 1/3/17 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. Show that the water closet is located in a space which provides: Rest room detail 1/A6.1 does not provide the clear 60" between the toilet and wall adjacent to the lay. See below i) Please notice that the 28" clearance required in the previous code (between the water closet and the lavatory) has been changed to a 60" clearance as shown in the figure. Carlsbad PC20 16-003 8 1/3/17 CENTERLINE OF FIXTURE 17"-18" ENTERLINE OF FIXTURE 18" M IN. FLUSH ACTIVATOR ON WIDE SIDE 28"MIN. TO EDGE crwitr - CLOG[T LU 18". \ 32" MIN MIN, \CLEAR Roof top GFI protected receptacle is required within 25ft of the new HVAC equipment. See sheet E2.1. The architectural details for the rest rooms shown on sheet A61 shows a floor drain in each unisex rest room. See general note 612 on sheet A6.1. The plumbing plans on sheet P1.1 do not show a floor drain within the rest rooms. Expand the Green Code note 703.1 found on sheet AO.4 to include the following: Prior to final inspection the licensed contractor, architect or engineer in responsible charge of the overall construction must provide to the building department official written verification that all applicable provisions from the Green Building Standards Code have been implemented as part of the construction. CGC 102.3. Carlsbad PC20 16-0038 1/3/17 5. Include as part of the architectural plans the required R-30 roof insulations and R-1 3 wall insulation on exterior walls and walls between office and warehouse. See energy form NRCC-PRF-01 page 8 of 20. END OF PLAN REVIEW To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you. SAN DIEGO REGIONAL I OFFICE USE ONLY c; HAZARDOUS MATERIALS RECORD ID #____________________________________ IPLAN CHECK #__________________ QUESTIONNAIRE BP DATE I I Business Name Business Contact Telephone # R19F f c4.t '-a' /9d9, £I4 A 7O -4 -22-8 R Project Address City State Zip Code I APN# 2A(o Xioc,/oc /o7 O? /2O JO Mailing Address IF V City State Zip Code Plan File# '92&24. Project Contact 5,'1i Appl(cant E-mail /s; % Telephone # co eq -S (,4 - /A9,2 . CC - Tfle following questions represent the facility's activities, NOT the specific project description. PART I: FIRE DEPARTMENT -HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: (not required for projects within the City of San Diego): Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Occupancy Rating: Facility's Square Footage (including proposed project): Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 13. Corrosives Compressed Gases 6. Oxidizers 10. Cryogenics 14. Ith Hazards Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials . None of Thes Flammable Solids 8. Unstable Reactives 12. Radioactives Call (858) 505-6700 prior to the issuance of a building permit. FEES ARE REQUIRED Project Completion Date: Expected Date of Occupancy: YES NO (for new construction or remodeling projects) 0 19 Is your business listed on the reverse side of this form? (check all that apply). 0 9 Will your business dispose of Hazardous Substances or Medical Waste in any amount? 0 l Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500 pounds and/or 200 cubic feet? 0 Will your business store or handle carcinogens/reproductive toxins in any quantity? 0 ' Will your business use an existing or install an underground storage tank? 0 Will your business store or handle Regulated Substances (CalARP)? 0 J Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? 0 , Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act). If the answer to any n Diego, CA 92123. CaIARP Exempt Date Initials CalARP Required Date Initials CalARP Complete Date Initials PART III: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCD): Any YES* answer requires a stamp from APCD 10124 Old Grove Road, San Diego, CA 92131 apcdcomgsdcounty.ca.gov (858) 586-2650). NO stamp required if QI Yes and Q3 Yes and Q4-06 No]. The following questions are intended to identify the majority of air pollution issues at the planning stage. Projects may require additional measures not identified by these questions. For comprehensive requirements contact APCD. Residences are typically exempt, except - those with more than one building on the property; single buildings with more than four dwelling units; townhomes; condos; mixed-commercial use; deliberate burns; residences forming part of a larger project. [Excludes garages & small outbuildings.] YES NO 0 Will the project disturb 160 square feet or more of existing building materials? 0 II Will any load supporting structural members be removed? Notification may be required 10 working days prior to commencing demolition. 0 0 (ANSWER ONLY IF QUESTION I or 2 IS YES) Has an asbestos survey been performed by a Certified Asbestos Consultant or Site Surveillance Technician? 0 0 (ANSWER ONLY IF QUESTION 3 IS YES) Based on the survey results, will the project disturb any asbestos containing material? Notification may be required 10 working days prior to commencing asbestos removal. 0 I Will the project or associated construction equipment emit air contaminants? See the reverse side of this form or APCD factsheet (www.sdaocd.org/info/factsIoermits.pdfl for typical equipment requiring an APCD permit. 0 0 (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school boundary Briefly describe business activities, Briefly describe proposed project: I declare und& penalt of perjury that to the best of my knowledge and belief e responses de her in are1true and correct. L4s ______________ Name of Owner or Authorized Agent Signature of Owner or ize_d Agent Date FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: FOR OFFICAL USE ONLY: BY: DATE: I I EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR occucv RELEASED FOR OCCUPANCY COUNTYHMD* APCD COUNTY-HMD APCD COUNTY-HMD APCD ." LdrIlp iii L"Ib uuA gaiX emps ousunesses rrom compietung or updating a I-Iazaraous Materials Business Plan. Other permitting requirements may still apply. HM-9171 (08/15) County of San Diego - DEH - Hazardous Materials Division iT I 1/ 0.10. I: SUITE 100: C)?COt(c - OFFICE (B) 518 S F WAREHOUSE (S-i) TOTAL 8,183 S.F. SUITE 103: :glo q_ WAREHOUSE (S-i) c,94S:F: OFFICE (B) TOTAL 4, 857 S.F. V SUITE 104: C3cO I1 -Ok OFFICE (B) WAREHOUSE (S-i) TOTAL 3, 408 S.F. / SUITE 105: C6CO)L jF2 v i OFFICE (B) WAREHOUSE (S-i) 2,460 TOTAL 3, 431 S.F. A6 ENLARGED RESTROOM PLAN AND Nt I IUUIVI LCVPS A6.2 MILLWORK AND GLAZING ELEVATIONS A6.2a MILLWORK DETAILS A7.1 DOOR SCHEDULE AND DETAILS A8.1 INTERIOR WALLS A8.2 CEILINGS A8.3 FINISHES & MISCELLANEOUS ARCHITECTURAL SHEET COUNT: 21 ELECTRICAL E1.1 NOTE SHEET E1.2 ITITLE 24 - i E1.3 I TITLE 24-2 E1.4 ILIGHTING DETAIL SHEET E2.1 FIRST FLOOR LIGHTING PLAN E2.2 FIRST FLOOR POWER PLAN E2.3 ROOF ELECTRICAL PLAN E3.1 SINGLELINE DIAGRAM E4.1 PANEL SCHEDULES E5.1 (DETAIL SHEET 1 E5.2 (DETAIL SHEET 2 ELECTRICAL SHEET COUNT: 11 MECHANICAL MO.1 MECHANICAL SCHEDULES, LEGEND, NOTES & T-24'S MO.2 MECHANICAL T-24'S MO .3 MECHANICAL ENVELOPE CALCULATIONS MO.4 1MECHANICAL ENVELOPE CALCULATIONS M1.1. (PARTIAL MECHANICAL FLOOR PLAN M1.2 IPARTIAL MECHANICAL FLOOR PLANS -SUITE B M2.1 (PARTIAL MECAHNICAL ROOF PLAN M2.2 PARTIAL MECHANICAL ROOF PLANS M3.1 MECHANICAL DETAILS M4.1 (MECHANICAL SPECIFICATIONS MECHANICAL SHEET COUNT: 10 SUITE 109: COJ&-OJO7 PLUMBING P0.1 PLUMBING SCHEDUES, LEG! OFFICE (B) 567 SF P1.1 PARTIAL PLUMBING FLOOR I WAREHOUSE (S-i) P1.2 PARTIAL PLUMBING FLOOR I TOTAL -3,386S . . I F. TOW 5, Jt L P2.1 PLUMBING ROOF PLAN P2.2 PLUMBING ROOF PLANS 1 P3.1 PLUMBING DETAILS P4.1 PLUMBING SPECIFICATIONS PLUMBING SHEET COUNT: 7 & -SUITE B 1__C0ty of Carlsbad Print Date: 06/21/2019 Permit No: PREV2017-0118 Job Address: 2864 Whiptail Loop Permit Type: BLDG-Permit Revision Work Class: Residential Permit Revisi Status: Closed - Finaled Parcel No: Lot if: Applied: 06/12/2017 Valuation: so.00 Reference #: Issued: 06/27/2017 Occupancy Group: . Construction Type Permit 06/21/2019. Finaled: if Dwelling Units: . Bathrooms: Inspector: Bedrooms: Orig. Plan Check if: PC2016-0038 Final Plan Check if: Inspection: Project Title: Description: ELEVATE: ADD DEMISING WALL TO CREATE 2 SUITES 108 & 109 Applicant: Owner: Contractor: WARE MALCOMB ARCHITECTS A P G CARLSBAD I LLC TFW CONSTRUCTION DEVELOPMENT INC LISA SMITH 6363 Greenwich Dr 1010 Coast Highway 101 5 C/O Raf Pacifica P0 Box 220 San Diego, CA 92122-5947 Group (SlConb), 103 DEL MAR, CA 92014 619-829-2988 ENCINITAS, CA 92024 858-759-1223 FEE AMOUNT MANUAL BUILDING PERMIT FEE $145.00 Total Fees: $ 145.00 Total Payments To Date: $ 145.00 Balance Due: $0.00 Building Division . . 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov c City of PLAN CHECK REVISION Development Services 1635 Faraday Avenue Carlsbad B-1 APPLICATION Building Division 5 760-602-2719 www.carlsbadca.gov Plan Check Revision NOPREV'2 7 0118 Original Plan Check No. _f 201 -Qo 3g Project Address 2,99 5" t-'//47 TAlL 4012J ea.ricbr/, c,4 Date_o4i2 e /7 Contact_L.s& s*L Ph 29 egg3 Fax Email L &'.t € cn - corn Contact Address i,i 4 c /7 City ,5, zip _YL/2 2 General Scope of Work ,iij d.ii'si ci uaJ/ iwi -5 i4. ___I Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1. Elements revised: M Plans LI Calculations E1 Soils E Energy LI Other 2. Describe revisions in detail 3. List page(s) where each revision is shown 4. List revised sheets that replace existing sheets AJIAi eiaJf 13ekjeo,l ca,/ /pç 'p Does this revision, in any way, alter the exterior of the project? LI Yes No Does this revision add ANY new floor area(s)? fl Yes M No Does this revision affect any fire related issues? LI Yes X1 No S. Is this a complete set? L] Yes No .€S'Signature 1635 Faraday Avenue, Carlsbad, CA 92008 ti: 760-602-2719 f: 760-602-8558 Email: building@carlsbadca.gov www.carlsbadca.gov EsGil Corporation / In PartnersIiip with government for (Bui&(ing Safety DATE: 6/21/17 JURISDICTION: Carlsbad PLAN CHECK NO.: PC2016-0038 REV. SET: I PROJECT ADDRESS: 2864 Whiptail Loop #100/3/4/5/9 PROJECT NAME: Spec TI for Suites 102, 106, 107 & 108 U APPLICANT )JURIS. O PLAN REVIEWER O FILE The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. El The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. El The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. LIII EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: 40--(bylfl—) Email: Mail Telephone Fax In Person REMARKS: PREV20I7-0118 By: Kurt Culver for CM Enclosures: Previously-approved EsGil Corporation plans [I GA DEJMB IPC 6/15/17 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576 Carlsbad PC2016.0038 REV 6/21/17 [DO NOT PAY - THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: PC2016-0038 REV PREPARED BY: Kurt Culver for CM DATE: 6/21/17 BUILDING ADDRESS: 2864 Whiptail Loop #100/3/4/5/9 BUILDING OCCUPANCY: B, Si BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) 46.51 Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code ICb IBY Ordinance Bldg. Permit Fee by Ordinance • I I Plan Check Fee by Ordinance V $145.00I Type of Review:' LI Complete Review U Structural Only U Repetitive Fee LI Other Repeats Hourly I Hr. @* EsGil Fee $116.00 I $116.00I * Based on hourly rate Comments: Sheet of 1 macvalue.doc + rcity pf Carlsbad Print Date: 06/21/2019 Permit No: PREV2017-0064 Job Address: 2864 Whiptail Loop Permit Type: BLDG-Permit Revision Work Class: Residential Permit Revisi Status: Closed - Finaled Parcel No: Lot #: Applied: 04/10/2017 Valuation: $ 0.00 Reference #: Issued: 05/01/2017 Occupancy Group: Construction Type Permit 06/21/2019 Finaled: U Dwelling Units: Bathrooms: Inspector: Bedrooms: Orig. Plan Check U: PC2016-0038 Final Plan Check U: Inspection: Project Title: Description: ELEVATE: REVISION TO SUITE 109 (CBC2016-0107 INCREASE OFFICE BY 127 SF TO ADD RESTROOM) Applicant: Owner: Contractor: WARE MALCOMB ARCHITECTS A P G CARLSBAD I LLC TFW CONSTRUCTION DEVELOPMENT INC LISA SMITH 6363 Greenwich Dr 1010 Coast Highway 101 5 C/O Raf Pacifica P0 Box 220 San Diego, CA 92122-5947 Group (SlConb), 103 DEL MAR, CA 92014 619-829-2988 ENCINITAS, CA 92024 858-759-1223 FEE AMOUNT MANUAL BUILDING PERMIT FEE $125.00 Total Fees: $ 125.00 Total Payments To Date: $ 125.00 Balance Due: $0.00 Building Division 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-2700 1 760-602-8560 f I www.carlsbadca.gov 4ccity of PLAN CHECK REVISION Development Services Building Division Carlsbad ' APPLICATION 1635 Faraday Avenue B-15 760-602-2719 www.carlsbadca.gov Plan Check Revision NLPEVZ6I7 (LL Original Plan Check No.Z'2flI .o Project Address 2 Wi \ix..t lJXf' Date Contact U O... S mljrix Ph Fax Email J5J i±bioc 1uko L.4C flc ContactAddress_(93(o G QAJCJI cArJf- City 3aM1)i€r Ci p 12.iza General Scope of Work €bt! Oc cred pe 40 ét add o rX c. Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1 . Elements revised: Plans fl Calculations Soils 0 Energy E1 Other 2. Describe revisions in detail 3. List page(s) where each revision is shown 4. List revised sheets that replace existing sheets 703 \No'-1 Btc Does this revision, in any way, alter the exterior of the project? LII Yes Does this revision add ANY new floor area (s)? I1 Yes IJ No Does this revision affect any fire related issues? Yes No Is this a compleet? Eves 7No €SSign 1635 Faraday Avenue, Carlsbad, CA 92008 EL2: 760-602- 2719 Fax: 760-602-8558 Email: building@carlsbadca.gov www.carlsbadca.g0v a: -C C 'C LL ft 3 I I- 3 LL LL -C Li. Li. ft >- a: F-a Li. C- 'C Li. ft ft Li. I I- C >- C C Li. Cf a: I- C I (I C a CONSTRUCTION CHANGE CHANGE SHEET INDEX: ARCHITECTURAL: AO.1 TITLE SHEET A11.0 OVERALL FLOOR PLAN A1.1 OCCUPANCY AND EGRESS PLANS A2.1 FLOOR PLANS A3.1 POWER AND SIGNAL PLANS A4.1 REFLECTED CEILING PLANS A4.1a ENLARGED REFLECTED CEILING PLANS A5.1 FINISH PLANS A6.1a ENLARGED R.R. PLANS & R.R. ELEVATIONS A6.2 MILLWORK & GLAZING ELEVATIONS A7.1 DOOR SCHEDULE AND DETAILS ELECTRICAL: E11.2 TITLE 24-1 E11.3 TITLE 24-1 E2.1 TITLE 24-1 E2.2 FIRST FLOOR POWER PLAN E2.3 FIRST FLOOR MECHANICAL PLAN E4.1 PANEL SCHEDULES MECHANICAL: MO.2 MECHANICAL T-24S MO.3 MECHANICAL ENVELOPE CALCULATIONS MO.4 MECHANICAL ENVELOPE CALCULATIONS M1.2 PARTIAL MECHANICAL FLOOR PLANS - SUITE B PLUMBING: P1.2 PLUMBING MEZZANINE FLOOR PLAN SUITE #109 REVISED SO. FT. SUITE #109 REVISED SO. FT. SUITE #109 REVISED FLOOR PLAN, OCCUPANCY SQ.FT RESTROOM SUMMARY, AND EXITING ANALYSIS SOFT. SUITE #109 REVISED SCOPE OF WORK SUITE #109 REVISED SCOPE OF WORK SUITE #109 REVISED SCOPE OF WORK SUITE #109 REVISED SCOPE OF WORK. SUITE #109 REVISED SCOPE OF WORK SUITE #109 ADDED SINGLE RESTROOM REMOVED N/A SUITE 105 BREAK ROOM AND GLAZING ELEVATIONS SUITE #109 OFFICE DOORS NO LONGER IN SCOPE OF WORK UPDATED TITLE 24 TO MATCH UPDATED LIGHTING ON FLOOR PLANS. UPDATED TITLE 24 TO MATCH UPDATED LIGHTING ON FLOOR PLANS. UPDATED LIGHTING IN OPEN OFFICE #102, AND ADDED LIGHTING/SWITCHING INTO RESTROOM #106. - UPDATED POWER IN OPEN OFFICE #102, ADDED RECEPTACLE IN RESTROOM #106, MOVED PANELS AND TRANSFORMER TO OTHER WALL TO AVOID NEW WINDOW FROM OPEN OFFICE. ADDED EXHAUST FAN IN RESTOOM #106, UPDATED - CIRCUIT FOR WH-1 (THERE WAS A TYPO). UPDATED PANEL SCHEDULES TO REFLECT LIGHTING, POWER, AND MECHANICAL CHANGES. TITLE 24 WAS UPDATED PER NEW SUITE #109 FLOOR PLAN ENVELOPE CALCULATIONS WERE UPDATED PER NEW SUITE #109 FLOOR PLAN ENVELOPE CALCULATIONS WERE UPDATED PER NEW SUITE #109 FLOOR PLAN EXHAUST FAN AND SUPPLY AIR ADDED TO NEW RESTROOM. DIFFUSER/REGISTER LAYOUT ALTERED PER NEW FLOORPLAN NEW PLUBMING FIXTURES AND CONNECTIONS IN NEW RESTROOM. WASTE AND VENT DIAGRAM UPDATED. EsGil Corporation In tFartnersfiip with government for(Building Safety DATE: 4/19/17 U APPLICANT , JURIS. JURISDICTION: 1sba4J U PLAN REVIEWER C3 FILE PLAN CHECK NO.:.. PREV2017-0064 (PC2016-0038) SET: REV 1, Set I PROJECT ADDRESS: 2864 Whiptail Loop #100/3/4/5/9 PROJECT NAME: Spec TI for Suites 102, 106, 107 & 108 The revised plan sheets transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. El The applicant's copy of the check list has been sent to: L EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted:— Telephone #: ( Date contacted: (b_J Email: Mail Telephone Fax In Person Li REMARKS: By: Chuck Mendenhall Enclosures: EsGil Corporation 0 GA 0 EJ 0 MB 0 PC 4/11/17 .1 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad PREV20 17-0064 (PC20 16-0038) 4/19/17 [DO NOT PAY — THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: PREV2017-0064 (PC2016-0038) PREPARED BY: Chuck Mendenhall DATE: 4/19/17 BUILDING ADDRESS: 2864 Whiptail Loop #100/3/4/5/9 BUILDING OCCUPANCY: B, Si BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Revised TI 127 Hrly Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code Icb IBY Ordinance I Bldg. Permit Fee by Ordinance v Plan Check Fee by Ordinance I Type of Review: 0 Complete Review 0 Structural Only 0 Repetitive Fee 0 Other Repeats Hourly I 1IHr.@* EsGil Fee I * Based on hourly rate I $100.00I Comments N/A In addition to the above fee, an additional fee of $ is due( hour @$ /hr.) for the CaIGièen review. Sheet I of I macvalue.doc +