HomeMy WebLinkAbout2870 Whiptail Loop; 107; CBC2016-0069; PermitCity of Carlsbad 1635 Faraday Av Carlsbad,CA 92008 Print Date: 04/26/2017 Commercial Permit Permit No: CBC2016-0069 www.carisbadca.gov lob Address:2870 Whiptail Loop, 107 Permit Type:BLDG-Commercial Work Class:Tenant Improvement Status:Closed -Finaled Parcel No:2091201000 Lot #:Applied:12/15/2016 Valuation:$511,330.94 Reference #:Issued:02/03/2017 Occupancy Group:Construction Type:Finaled: # Dwelling Units:Bathrooms:Inspector:AKrog Bedrooms:Orig. Plan Check #: Plan Check #: Project Title: Description:RAF PACIFICA GROUP: TI SHELL TO WAREHOUSE STORAGE 7,287 SF &OFFICE 3707 SF Applicant:Owner:Co-Applicant: DAV HEALTHCARE SERVICES A P G CARLSBAD I LLC WARE MALCOMB ARCHITECTS LISA MARIE SMITH LISA SMITH 2221 Las Palmas Dr,J 1010 Coast Highway 101 5 C/O Raf Pacifica 6363 Greenwich Dr Carlsbad,CA 92011-1528 Group (S1Conb), 103 San Diego, CA 92122-5947 760-607-0924 ENCINITAS, CA 92024 619-829-2988 BUILDING PERMIT FEE $2000+$2,073.00 BUILDING PLAN CHECK FEE (BLDG)$1,451.10 ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL $242.00 FIRE S Occupancies < 50,000sq. ft.TI $362.00 GREEN BUILDING STANDARDS PLAN CHECK $166.00 MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL $104.00 PUBLIC FACILITIES FEES -inside CFD $9,306.22 SB1473 BUILDING STANDARDS FEE $21.00 SEWER BENEFIT AREA FEES -E $4,511.76 SEWER CONNECTION FEE (General Capacity all areas)$1,186.68 STRONG MOTION-COMMERCIAL $143.17 TRAFFIC IMPACT Commercial-Industrial w/in CFD $6,540.00 Total Fees:$26,106.93 Total Payments To Date:$26,106.93 Balance Due:$0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project.NOR DOES IT APPLYto any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. • THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE:OPLANNING EENGINEERING OBUILDING EFIRE ci HEALTH EINAZMATIAPCD Building Permit Application Plan Check No.C6Cao 1 .-DooCity of 1635 Faraday Ave., Carlsbad, CA 92008 Est. Value it 51/Ltybo .9/4 Ph: 760-602-2719 Fax: 760-602-8558Carlsbademail: building@carlsbadca.gov Plan Ck. Deposit www.carlsbadca.gov Date jan5//6 SWPPP JOB ADDRESS C041S 10A ci SUITEVSPACEVUNIT#APN Q"00 1)411 eta -Al tj.Q.e(\o\.tc .0s.).:sAuto Gx.4 aoto to-- 1 °ci -I a 0 t (-.)- CT/PR JECT#LOT #PH ##OF UNITS #BEDROOMS # BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE OCC. GROUP DESCRIPTION OF WORK:Include Square Feet of Affected Area(s)2 1 ° 7 OfCCA...Ten:trt+prover:mekx-ot-6K.o.Waret-t0u-Ssa"°C.C.(c•-e-••i -1,-S -7 S tbrot152- EXISTING USE PRWSED USE GARAGE (SF)PATIOS (SF)DECKS (SF)FIREPLACE AIR CONDITIONING FIRE SPRINKLERS V\e_A 1 0%u_j \NOR__yEsEitt.NOE YES ONOEl YESO NO1 - 1 APPLICANT NAME i s .PROPERTY OWNER NAME ,., Primary Contact L.%s la-5 ry‘..*in.21..F Fackhc.A.GY'llimP ADDRESS ADDRESS Co 3 (..3 Gme-bAvulk -ick Dr-•l 2- 7 Lo yvt.4. S S .e.Wk-a.'Fe Or . CITY STATE ZIP CITY STATE ZIPN.SCIAN.Ul eat i CO-•1 2.1 2-'2.e-nci Al i-a.S ,Co.. 7 ..015 PHONE FAX PHONE FAX 6 ICI -$60 4 -5I 2 to -16.0 -473 -8838 /(DO -4%-284-7 EMAIL EMAIL I S roN 1 il•e.VJa.e.•ry•o.Acovv•b •corn DESIGN PROFESSIONAL CONTRACToR KR.INAmE7.7.=&./.57Relef--76.0 11)--k/ _zue... ADDRESS 1-z. ADDRESS 74600 TOi-55/64.114-ex Y?ei .-C7-6-2.440 CITY STATE ZIP CITY STATE/ZIP )f}ot) --b-/E-‘O ./1---?ZOO PHONE FAX PHONE FAX W?22b 4Lffn (/9 tZD zi-(f625 --- EMAIL EMAIL-rebWE6 k LiZd 1-FW ez).05/xaci—fp.v. ee) /IN STATE LIC.#STATE LIC.#Z/CLASS CITY BUS. LIC.#B (Sec.7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of theBusiness and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). 4:eJ...,W.,F63,19.,„ii k..L.':s E N S A T I 0 N •..'iP,..!. Workers' Compensation Declaration:I hereby affirm under penalty of perjury one of the following declarations: EIhave and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation ins ante cyrrier and policy number are: Insurance Co.57-47E ecvn-P3--46.-•'(/-1/Policy No.4.e)6-70 2 Expiration Date 06 /D//'o.'7 This section need not be completed if the permit is for one hundred dollars ($100) or less.0 Certificate of Exemption:I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California.WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (8100,000), in addition to the cost of compensation,d i7 __-4J .ges as provided for in Section 3706 of the Labor code, interest and attorney's fees. AlCONTRACTOR SIGNATURE ...•'eax 7---: -0 AGENT DATE .v1---/3 /-6 /7..ec OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from Contractor's License Law for the following reason: O I,as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale.If,however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I,as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). EII am exempt under Section Business and Professions Code for this reason: 1.I personally plan to provide the major labor and materials for construction of the proposed property improvement.0Yes EINo 2.1 (have I have not) signed an application for a building permit for the proposed work. 3.I have contracted with the following person (firm) to provide the proposed construction (include name address I phone / contractors' license number): 4.I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address / phone / contractors' license number): 5.I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address I phone / type of work): g<PRAPFRTY CMINFR SIGNATURE [1AGENT DATE latirth'i;:gl.ETE THIS ‘"SECTION FOR NON -RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act?Yes No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?Yes No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site?Yes No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET ORIS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. CONSTRUCTION LENDING AGENCY - I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address TrionAPPLICANTCERTIFICATION . I certify thatI have read the application and state thatthe above information is comet and that the information on the plans is accurate.Iagree to complywith all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes.IALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5D' deep and demolition or construction of structures over 3 storiesin height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permitis not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). ..eAPPLICANT'S SIGNATURE DATE 102 — AWAlk Arai/ ,• OP STOP:THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. Fax (760) 602-8560, Email buildingPcarlsbadca.gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. CO#:(Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE FAX EMAIL OCCUPANT'S BUS. LIC. No. DELIVERY OPTIONS PICK UP:CONTACT (Listed above)OCCUPANT (Listed above) CONTRACTOR (On P.1) ASSOCIATED CB#MAIL TO:CONTACT (Listed above)OCCUPANT (Listed above) CONTRACTOR (On Pg. 1)NO CHANGE IN USE/NO CONSTRUCTION MAIL/FAX TO OTHER: CHANGE OF USE /NO CONSTRUCTION 2SAPPLICANT'S SIGNATURE DATE • PERMIT INSPECTION HISTORY REPORT (CBC2016-0069) Permit Type:BLDG-Commercial Application Date:12/15/2016 Owner:A P G CARLSBAD I LLC Work Class:Tenant Improvement Issue Date:02/03/2017 Subdivision: Status:Closed -Fineled Expiration Date:09/18/2017 Address:2870 Whiptail Loop, 107 Carlsbad, CA IVR Number:841 Scheduled Actual Date Start Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Complete 02/06/2017 02/06/2017 BLDG-14 012872-2017 Partial Pass Paul York Reinspection Incomplete Frame/Steel/Bolting/ Welding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 02/15/2017 02/15/2017 BLDG-24 013730-2017 Partial Pass Paul York Reinspection Incomplete Rough/Topout Checklist Item COMMENTS Passed BLDG-Building Deficiency No 02/17/2017 02/17/2017 BLDG-17 Interior 014011-2017 Cancelled Michael Collins Reinspection Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-44 014012-2017 Failed Michael Collins Reinspection Complete Rough/Ducts/Dampe rs Checklist Item COMMENTS Passed BLDG-Building Deficiency No 02/24/2017 02/24/2017 BLDG-12 Steel/Bond 014738-2017 Passed Andy Krogh Complete Beam BLDG-17 Interior 014737-2017 Passed Andy Krogh Complete Lath/Drywall BLDG-31 014736-2017 Passed Andy Krogh Complete Underground/Condu it -Wiring 03/01/2017 03/01/2017 BLDG-Electric Meter 015040-2017 Passed Andy Krogh Complete Release 03/20/2017 03/20/2017 BLDG-85 T-Bar,017014-2017 Passed Andy Krogh Complete Ceiling Grids, Overhead Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 03/27/2017 03/24/2017 BLDG-Final 017606-2017 Partial Pass Andy Krogh Reinspection Incomplete Inspection April 26, 2017 Page 1 of 2 PERMIT INSPECTION HISTORY REPORT (CBC2016-0069) Permit Type:BLDG-Commercial Application Date:12/15/2016 Owner:A P G CARLSBAD I LLC Work Class:Tenant Improvement Issue Date:02/03/2017 Subdivision: Status.:Closed -Finaled Expiration Date:09/18/2017 Address:2870 Whiptail Loop, 107 Carlsbad, CA IVR Number:841 Scheduled Actual Date Start Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-Plumbing Final No BLDG-Mechanical Final No BLDG-Structural Final No BLDG-Electrical Final No 04/26/2017 04/26/2017 BLDG-Final 021262-2017 Passed Andy Krogh Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes April 26, 2017 Page 2 of 2 ..,..._ ,• ,..4 CBC2016-0069,.V CITY OF # 107CARLSBADINSPECTION RECORE 2870 WHIPTAIL LOOP Building Division RAF PACIFICA GROUP: TI SHELL TO WAREHOUSE STORAGE 7.287 SF &OFFICE 3707 SF El INSPECTION RECORD CARD WITH APPROVED PLANS MUST BE KEPT ON THE JOB 1l CALL BEFORE 3:00 pm FOR NEXT WORK DAY INSPECTION C0'1 2091201000 iii FOR BUILDING INSPECTION CALL:760-602-2725 12/15/2016 OR GO TO: www.Carisbadca.gov/Buildinq AND CLICK ON t COIC.)CBC 2 016-0069"Reque tin pection" DATE:2 5 I g If "YES" is checked below that Division's approval is required prior to requesting a Final Building Inspection. If you have any questions please call the applicable divisions at the phone numbers provided below. After all required approvals are signed off-fax to 760-602-8560. email to bldginspections@carisbadca.gov or bring in a COPY of this card to: 1635 Faraday Ave.. Carlsbad. NO YES Required Prior to Requesting Building Final Checked YES Date Inspector Notes 1 Planning/Landscape 760-9448463 .Allow 48 hours CAW (Engineering Inspections) Fire Prevention 760-438-3891 Call before 2 pm 760-602-4660 Allow 48 hours :3/1I1 a .;1 Type of Inspection .Type of Inspection cooc #BUILDING Date Inspector coDE #ELECTRICAL Date Inspector #11 FOUNDATION P4 / 7 .Aiat #31 0 ELECTRIC UNDERGROUND 0 UFER #12 REINFORCED STEEL #34 ROUGH ELECTRIC #66 MASONRY PRE GROUT #33 .RrILECTRIC SERVICE 0 TEMPORARY g -1.-i7 A-614.__ 0 GROUT 0 WALL DRAINS #35 PHOTO VOLTAIC #10 TILT PANELS #53 ELEC/CONDUIT/WIRING #11 POUR STRIPS #39 FINAL #11 COLUMN FOOTINGS coot st MECHANICAL #14 SUBFRAME 0 FLOOR 0 CEILING #41 UNDERGROUND DUCTS &PIPING #15 ROOF SHEATHING #44 0 DUCT &PLENUM 0 REF. PIPING #13 EXT. SHEAR PANELS #43 HEAT-AIR COND. SYSTEMS #16 INSULATION •#49 FINAL #18 EXTERIOR LATH coot rt COMBO INSPECTION #17 INTERIOR LATH &DRYWALL ''a.-47 °."7"#81 UNDERGROUND (11,12,21,31) #51 POOL EXCA/STEEL/BOND/FENCE #82 DRYWALL,EXT LATH, GAS TES (17,18,23) #55 PREPLASTER/FINAL #83 ROOF SHEATING, EXT SHEAR (13,15) #19 FINAL #84 FRAME ROUGH COMBO (14,24,34,44) C oot #PLUMBING Date Inspector #85 T-Bar (14,24,34,44)3 -20-17 Mae #22 0 SEWER & BL/CO 0 PL/CO #89 FINAL OCCUPANCY (19,29,39,49) #21 UNDERGROUND OWASTE 0 WTR Date Ins ector #24 TOP OUT 0 WASTE 0 WTR 1 /20 t7 lif A/S UNDERGROUND VISUAL ... #27 TUB &SHOWER PAN A/S UNDERGROUND HYDRO #23 0 GAS TEST 0 GAS PIPING A/S UNDERGROUND FLUSH #25 WATER HEATER A/S OVERHEAD VISUAL 4.7).7#28 SOLAR WATER A/S OVERHEAD HYDROSTATIC #29 FINAL A/S FINAL 3/ZA- 371'7 01:2 - 7,-..M. coot#STORM WATER F/A ROUGH-IN #600 PRE-CONSTRUCTION MEETING F/A FINAL ,,,.174.:Z."";0140 .•.'70"94."-t.i #603 FOLLOW UP INSPECTION FIXED EXTINGUISHING SYSTEM ROUGH-IN #605 NOTICE TO CLEAN FIXED MING SYSTEM HYDROSTATIC TEST #607 WRITTEN WARNING FIXED EXTINGUISHING SYSTEM FINAL #609 NOTICE OF VIOLATION MEDICAL GAS PRESSURE TEST #610 VERBAL WARNING MEDICAL GAS FINAL EsGil Corporation In Partnership with Governmentfor Building Safety DATE:01/31/2017 APPLICANT JURIS. JURISDICTION:City of Carlsbad PLAN REVIEWER FILE PLAN CHECK NO.:C2016-0069 SET:II PROJECT ADDRESS:2870 Whiptail Loop, Bldg. "A", Suite 107 PROJECT NAME:OFFICE/WAREHOUSE TI FOR ELEVATE B&D NUTRITIONAL X The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. 7 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information.The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: 17]EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted:Telephone #: Date contacted:(by:)Email: Mail Telephone Fax In Person REMARKS: By:Sergio Azuela Enclosures: EsGil Corporation GA EJ MB PC 01/23/2017 9320 Chesapeake Drive, Suite 208 San Diego, California 92123 (858) 560-1468 Fax (858) 560-1576 . EsGil Corporation In Partnership with Governmentfor Building Safety DATE:01/03/2017 OjAPPLICANT ..6 JURIS. JURISDICTION:City of Carlsbad 0 PLAN REVIEWER 0 FILE PLAN CHECK NO.:C2016-0069 SET:I PROJECT ADDRESS:2870 Whiptail Loop, Bldg. "A", Suite 107 PROJECT NAME:OFFICE/WAREHOUSE TI FOR ELEVATE B&D NUTRITIONAL ri The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. n The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. X The check list transmitted herewith is for your information.The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. ' The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: r7 EsGil Corporation staff did not advise the applicant that the plan check has been completed. [i<1 EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted:Lisa Smith Telephone #: 619-564-5126 Date contacted:115 (by:n(4 Email:Ismith@waremalcomb.com Mail ephon Fax In Person El REMA .`- '1)'\'' y By:Sergio Azuela Enclosures: EsGil Corporation 0 GA Eg EJ El MB 1:1 PC 12/19/2016 9320 Chesapeake Drive, Suite 208 •San Diego, California 92123 •(858) 560-1468 •Fax (858) 560-1576 City of Carlsbad C2016-0069 01/03/2017 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.:C2016-0069 JURISDICTION: City of Carlsbad OCCUPANCY:B, and S -1 USE:Office/Warehouse TYPE OF CONSTRUCTION:III-B ACTUAL AREA:10,994 SF (TI space only) ALLOWABLE FLOOR AREA:STORIES:1 HEIGHT: SPRINKLERS?:Yes OCCUPANT LOAD:48 REMARKS: DATE PLANS RECEIVED BY DATE PLANS RECEIVED BY JURISDICTION:ESGIL CORPORATION:12/19/2016 DATE INITIAL PLAN REVIEW PLAN REVIEWER: Sergio Azuela COMPLETED:01/03/2017 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Building Code,Uniform Plumbing Code,Uniform Mechanical Code,National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled.This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department,Engineering Department,Fire Department or other departments.Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2013 CBC, which adopts the 2012 IBC. The following items listed need clarification, modification or change.All items must be satisfied before the plans will be in conformance with the cited codes and regulations.Per Sec. 105.4 of the 2012 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process,please note on this list (or a copy)where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad C2016-0069 01/03/2017 •GENERAL 1.Please make all corrections, as requested in the correction list.Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects).For expeditious processing, corrected sets can be submitted in one of two ways: 1.Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700.The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2.Bring TWO corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE:Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. •PLANS 2.Provide a Building Code Data Legend on the Title Sheet. Include the following code information for each building proposed: Occupancy Classification(s).Revise the plans to show the Occupancy Classification for the adjacent space to the Proposed TI space, to check for any possible Fire Barrier requirements at the demising wall between the two spaces. Height 3.Provide a note on the plans indicating if any hazardous materials will be stored and/or used within the building which exceed the quantities listed in IBC Tables 307.1(1) and 307.1(2). 4.A complete description of the activities and processes that will occur in this tenant space should be provided. A listing of all hazardous materials should be included. The materials listing should be stated in a form that would make classification in Tables 307.1(1) and 307.1(2) possible. The building official may require a technical report to identify and develop methods of protection from hazardous materials. Section 414.1.3. •EXITS 5.Exit doors shall provide a clear width of not less than 32" when open 90 degrees (i.e., a 3' wide door), and must have a minimum height of 6 feet 8 inches. Maximum leaf width is 4 feet. Section 1008.1.1. a)Revise the plans to show all specifications for the existing exit doors. Section 107.2.3. •• City of Carlsbad C2016-0069 01/03/2017 6.Regardless of occupant load,a floor or landing not more than 1/2 inch below the threshold is required on each side of an egress door. Section 1008.1.7. 7.Note on the plans: "All egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort."Section 1008.1.9. In lieu of the above,in a Group B, F, M or S occupancies (or places of religious assembly or Group A occupancies having an occupant load of 300 or less), you may note on the plans "Provide a sign on or near the exit door, reading THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED." This signage is only allowed at the main exit.Section 1008.1.9.3. •EXIT SIGNS 8.Show that the means of egress path will be lighted with at least one foot candle at floor level. Section 1006. •ACCESSIBILITY 9.Provide notes and details on the plans to show compliance with the enclosed "Disabled Access" Review List. •NON-RESIDENTIAL GREEN BUILDING STANDARDS (Additions and Alterations) The California Building Standards Commission (BSC) has adopted the Green Building Standards Code which became effective January 1,2011, and must be enforced by the local building official.The Green Building Standards apply to nonresidential additions or tenant improvements throughout California. These standards apply to nonresidential additions of 1,000 sq. ft.or larger or alterations (tenant improvements) with a value of $200,000 or more.CGC Section 301.3.Provide a sheet on the plans labeled "Green Building Code Requirements" and include the following notes as applicable. 10.Documentation.Note on the plans that a building "Systems Manual" as listed in CGC Section 5.410.2.5 shall be delivered to the building owner or representative and the facilities operator. Further, note on the plans that the "Systems Manual" shall contain the required features listed in CGC Section 5.410.2.5.1. 11.Note on the plans that prior to final inspection the licensed contractor, architect or engineer in responsible charge of the overall construction must provide to the building department official written verification that all applicable provisions from the Green Building Standards Code have been implemented as part of the construction.CGC 102.3. City of Carlsbad C2016-0069 01/03/2017 To speed up the review process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list.If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes No The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation.Thank you. PLUMBING, MECHANICAL, ELECTRICAL, and ENERGY COMMENTS PLAN REVIEWER: Eric Jensen PLUMBING (2013 CALIFORNIA PLUMBING CODE) o The plumbing is fine as submitted. MECHANICAL (2013 CALIFORNIA MECHANICAL CODE) 1.Include an explanation of the roof access design on the plans:existing, new, located where, etc? ELECTRICAL (2013 CALIFORNIA ELECTRICAL CODE) 2.Somewhere describe where the main electrical service is located.If that's it on sheet A0.5 at the far opposite end of the building, include voltage drop calculations as well as a description of the wiring design from the existing service to the TI electrical equipment. 3.Include a description for the transformer grounding electrode itself. ENERGY (2013 CALIFORNIA BUILDING ENERGY STANDARDS) o The energy is fine as submitted. Note: If you have any questions regarding this Electrical, Plumbing, Mechanical, and Energy plan review list please contact Eric Jensen at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. DISABLED ACCESS REVIEW LIST City of Carlsbad C2016-0069 01/03/2017 •REMODELS, ADDITIONS AND REPAIRS 1.When alterations, structural repairs or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the following requirements, per Section 11B-202.4: •The area of specific alteration, repair or addition must comply as "new" construction. •A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features. •The path of travel shall include the existing parking. •SITE PLAN REQUIREMENTS 2.Clearly show that the site development and grading are designed to provide access to all entrances and exterior ground floor exits, as well as access to normal paths of travel, per Section 11B-206. Where necessary to provide access, shall incorporate pedestrian ramps, curb ramps, stairways and handrails, etc. a)Clearly show the details for all applicable elements included in the route of access shown between the building and the entrance to the proposed TI space. b)Clearly show on plans the complete route of access between the Public Way and the proposed TI space. •ACCESSIBLE PARKING 3.Show that the accessible parking spaces are located, per Section 11B-208.3.1 as follows: a)On the shortest possible route to an accessible entrance, when serving a particular building. •DOORS 4.Show or note that all hand-activated door opening hardware meets the following requirements, per Section 11B-404.2.7: a)Is to be centered 34" but 5.44"above floor.Revise the plans to show 34" minimum, instead of 30" at DOOR NOTE # 8 on sheet A5.1. END OF DOCUMENT City of Carlsbad C2016-0069 01/03/2017 (DO NOT PAY-THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION:City of Carlsbad PLAN CHECK NO.:C2016-0069 PREPARED BY: Sergio Azuela DATE:01/03/2017 BUILDING ADDRESS:2870 Whiptail Loop, Bldg. "A", Suite 107 BUILDING OCCUPANCY:B,85 S-1 BUILDING AREA 'Valuation Reg.VALUE ($) PORTION (Sq. Ft.)Multiplier Mod. Office TI 3707 511,330 Warehouse TI 7287 Air Conditioning Fire Sprinklers TOTAL VALUE 511,330 Jurisdiction Code cb By Ordinance Bldg.Permit Fee by Ordinance ‘' Plan Check Fee by Ordinance + 11-14.6(.10 Type of Review:1 -/Complete Review jl Structural Only Other (Repetitive FeeRepeats I Hourly Hr.@* EsGil Fee $1,161.03 Comments:In addition to the above fee, an additional fee of $43.00 is due (0.5 hour @ $86.00/hr.) for the CalGreen review. Sheet 1 of 1 macvalue.doc + • OFFICE USE ONLYSAN DIEGO REGIONALlik\'ig4;%.N z,,,,it - 10).86)RECORD ID # 1.-..."*A.;•!.' 0 HAZARDOUS MATERIALS PLAN CHECK # '4foccco QUESTIONNAIRE BP DATE // Businep Name Business Contact Telephone #g 1p Nu-iY1-71)e45 n .0.../_7 Gpl -65-0-3851 Project Address City State Zip Code APN# 2 370 Nh;07.ea &eve 6/44 c5kt....../07 R 0/-/20 -16 Mailing Address r City State Zip Code Plan File# /R51 L; loe.r+1/1-471 S144)62-14 0.51-0..i (902 04/Project Contact Applicant E-mail Telephone # del0.14)041/40 tiSal L5M 44‘15 e-rt (-41, .121.14:tr e rfria-e c_ 0 se1/46.crri„611 -664.-S/26The following questions represent the facility's activities, NOT the specific project description. PART I:FIRE DEPARTMENT -HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: (not required for projects within the City of San Diego):Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Occupancy Rating:Facility's Square Footage (including proposed project): 1.Explosive or Blasting Agents 5.Organic Peroxides 9.Water Reactives 13.Corrosives 2.Compressed Gases 6.Oxidizers 10.Cryogenics 1).,Other Health Hazards 3.Flammable/Combustible Liquids 7.Pyrophorics 11.Highly Toxic or Toxic Materials (...5)None of These. 4.Flammable Solids 8.Unstable Reactives 12.Radioactives PART II:SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISION (HMD): If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Avenue, Suite 110, San Diego, CA 92123. Call (858) 505-6700 prior to the issuance of a building permit. FEES ARE REQUIRED Project Completion Date:Expected Date of Occupancy:0 CalARP Exempt YES NO (for new construction or remodeling projects)/ 1.0 (g Is your business listed on the reverse side of this form? (check all that apply).Date Initials 2.f=1 jg Will your business dispose of Hazardous Substances or Medical Waste in any amount? 3.0 N4 Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500 0 CaIARP Required pounds and/or 200 cubic feet?/ 4.D 21 Will your business store or handle carcinogens/reproductive toxins in any quantity?Date Initials 5.0 igl Will your business use an existing or install an underground storage tank? 6.0 ®Will your business store or handle Regulated Substances (CaIARP)?DCalARP Complete 7.1=1 El Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)?/ 8.0 Igl Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to Date Initials or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act). PART III: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCD): Any YES* answer requires a stamp from APCD 10124 Old Grove Road, San Diego, CA 92131 apcdcompa.sdcounty.ca.gov (858) 586-2650).[*No stamp required if Q1 Yes and Q3 Yes and Q4-Q6 No].The following questions are intended to identify the majority of air pollution issues at the planning stage. Projects may require additional measures not identified by these questions. For comprehensive requirements contact APCD.Residences are typically exempt, except -those with more than one building'on the property; single buildings with more than four dwelling units; townhomes; condos; mixed-commercial use; deliberate burns; residences forming part of a larger project.['Excludes garages & small outbuildings.] YES NO 1.0 2J Will the project disturb 160 square feet or more of existing building materials? 2.0 ala Will any load supporting structural members be removed? Notification may be required 10 working days prior to commencing demolition. 3.0 0 (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Has an asbestos survey been performed by a Certified Asbestos Consultant or Site Surveillance Technician? 4.0 0 (ANSWER ONLY IF QUESTION 3 IS YES) Based on the survey results, will the project disturb any asbestos containing material? Notification may be required 10 working days prior to commencing asbestos removal. 5.0 ril Will the project or associated construction equipment emit air contaminants? See the reverse side of this form or APCD factsheet (www.sdapcd.orq/info/facts/permits.pdf) for typical equipment requiring an APCD permit. 6.0 0 (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school bounds Briefly describe bu 'ness activities:Briefly describe proposed project: av-e o I declare under enalty of perjury that to the best of my knowledge and belief e responses made he in are true and correct./2//S //6 Name of Owner or • i n ture of Owner o thorized A ent Date FOR OFFICAL USE ONLY:FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: BY:DATE:// EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMD*APCD COUNTY-HMD APCD COUNTY-HMD APCD *A stamp in this box only exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may still apply. LIST OF BUSINESSES WHICH REQUIRE REVIEW AND APPROVAL FROM THE COUNTY OF SAN DIEGO DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISION Check all that apply: AUTOMOTIVE CHEMICAL HANDLING OTHERS AND MISCEL EOUS Battery Manufacturing/Recycling Photographic Processing Asphalt Plant Boat Yard Pool Supplies/Maintenance Biotechnology/Research Car Wash Printing/Blue Printing Chiropractic Office Dealership Maintenance/Painting Road Coatings Co-Generation Pla Machine Shop Swimming Pool Dental Clinic/Offi - Painting Toxic Gas Handler Dialysis Center Radiator Shop Toxic Gas Manufacturer Emergency venerator Rental Yard Equipment Frozen F• •d Processing Facility Repair/Preventive Maintenance METAL WORKING Hazard•s Waste Hauler Spray Booth Anodizing Hosp.al/Convalescent Home Transportation Services Chemical Milling/Etching La ••ratory/Biological Lab Wrecking/Recycling Finish-Coating/Painting edical Clinic/Office Flame Spraying /Nitrous Oxide (NO.) Control System CHEMICAL HANDLING Foundry Pharmaceuticals Agricultural supplier/distributor Machine Shop-Drilling/Lathes/Mills Public Utility Chemical Manufacturer Metal Plating Refrigeration System Chemical Supplier/Distributor Metal Prepping/Chemical Coating Rock Quarry Coatings/Adhesive Precious Metal Recovery Ship Repair/Construction Compressed Gas Supplier/Distributor Sand Blasting/Grinding Telecommunications Cell Site Dry Cleaning Steel Fabricator Veterinary Clinic/Hospital Fiberglass/Resin Application Wrought Iron Manufacturing Wood/Furniture Manufacturing/Refinishing Gas Station Industrial Laundry AEROSPACE ELECTRONICS Laboratory Aerospace Industry Electronic Assembly/Sub-Assembly Laboratory Supplier/Distributor Aircraft Maintenance Electronic Components Manufacturing Oil and Fuel Bulk Supply Aircraft Manufacturing Printed Circuit Board Manufacturing Pesticide Operator/Distributor NOTE: THE ABOVE LIST INCLUDES BUSINESSES, WHICH TYPICAL USE, STORE, HANDLE, AND DISPOSE OF HAZARDOUS SUBSTANCES. ANY BUSINESS NOT INCLUDED ON THIS LIST, WHICH HANDLES SES OR DISPOSES OF HAZARDOUS SUBSTANCES MAY STILL REQUIRE HAZARDOUS MATERIALS DIVISION (HMD) REVIEW OF BUSINE PLANS. FOR MORE INFORMATION CALL (858) 505-6880. LIST OF AIR POLLUTIO ONTROL DISTRICT PERMIT CATEGORIES Businesses, which include any of the following open.ions or equipment, will require clearance from the Air Pollution Control District. CHEMICAL COM =USTION ROCK AND MINERAL 47 —Organic Gas Sterilizers 34 • iston Internal —Combustion Engines 04 —Hot Asphalt Batch Plants 32 —Acid Chemical Milling 1 —Boilers & Heaters (1 million BTU/hr or larger)05 —Rock Drills 33 —Can & Coil Manufacturing 4 —Incinerators & Crematories 06 —Screening Operations 44 —Evaporators, Dryers & Stills Processing 15 —Burn Out Ovens 07 —Sand Rock & Aggregate Plants Organic Materials 16 —Core Ovens 08 —Concrete Batch, CTB, Concrete Mixers, Mixers 24 —Dry Chemical Mixing & Detergent Spray 20 —Gas Turbines, and Turbine Test Cells & Stands & Silos Towers 48 —Landfill and/or Digester Gas Flares 10 —Brick Manufacturing 35 —Bulk Dry Chemicals Storage 55 —Chrome Electroplating Tanks ELECTRONICS OTHER 29 —Automated Soldering 01 —Abrasive Blasting Equipment COATINGS & ORGANIC SOLVE S 42 —Electronic Component Mfg 03 —Asphalt Roofing Kettles & Tankers 27 —Coating & Painting 46 —Reverse Osmosis Membrane Mfg 37 —Plasma Arc & Ceramic Depo ion Spray FOOD 51 —Aqueous Waste Neutralization Booths 12 —Fish Canneries 11 —Tire Buffers 38 —Paint, Stain & Ink Mfg 12 —Smoke Houses 17 —Brake Debonders 27 —Printing 50 —Coffee Roasters 23 —Bulk Grain & Dry Chemical Transfer & Storage 27 —Polyester Resin/Fiber•-ss Operations 35 —Bulk Flour & Powered Sugar Storage 45 —Rubber Mixers 21 —Waste Disposal & Reclamation Units METALS SOLVENT USE 36 —Grinding Booths & Rooms 18 —Metal Melting De ces 28 —Vapor & Cold Degreasing 40 —Asphalt Pavement Heaters 19 —Oil Quenching Salt Baths 30 —Solvent & Extract Driers 43 —Ceramic Slip Casting 32 —Hot Dip Galv-izing 31 —Dry Cleaning 41 —Perlite Processing 39 —Precious M -als Refining 40 —Cooling Towers —Registration Only 91 —Fumigation Operations ORGANIC •MPOUND MARKETING 56 —VVWTP (1 million gal/day or larger) & Pump GAS •INE ETC Station 25 —Gaso .ne & Alcohol Bulk Plants & Terminals 25 —Inter ediate Refuelers 26 —Ga oline & Alcohol Fuel Dispensing NOTE: OTHER EQUIPMENT NOT LISTED HERE THAT IS CAPABLE OF EMITTING AIR CONTAMINANTS MAY REQUIRE AN AIR POLLUTION CONTROL DISTRICT PERMIT. IF THERE ARE ANY QUESTIONS, CONTACT THE AIR POLLUTION CONTROL DISTRICT AT (858) 586-2600. HM-9171 (08/151 County of San Dieao —DEH —Hazardous Materials Division • INDUSTRIAL WASTEWATER DISCHARGE PERMIT /I-- WASTEWATER i AUTHORITY SCREENING SURVEY Date Business Name Street Address Email Address PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT:(ON REVERSE SIDE CHECK TYPE OF BUSINESS) Check all below that are present at your facility: Acid Cleaning Ink Manufacturing Nutritional Supplement/ Assembly Laboratory Vitamin Manufacturing Automotive Repair Machining /Milling Painting / Finishing Battery Manufacturing Manufacturing Paint Manufacturing Biofuel Manufacturing Membrane Manufacturing Personal Care Products Biotech Laboratory (i.e. water filter membranes)Manufacturing Bulk Chemical Storage Metal Casting / Forming Pesticide Manufacturing / Car Wash Metal Fabrication Packaging Chemical Manufacturing Metal Finishing Pharmaceutical Manufacturing Chemical Purification Electroplating (including precursors) Dry Cleaning Electroless plating Porcelain Enameling Electrical Component Anodizing Power Generation Manufacturing Coating (i.e. phosphating)Print Shop Fertilizer Manufacturing Chemical Etching / Milling Research and Development Film / X-ray Processing Printed Circuit Board Rubber Manufacturing Food Processing Manufacturing Semiconductor Manufacturing Glass Manufacturing Metal Powders Forming Soap / Detergent Manufacturing Industrial Laundry Waste Treatment / Storage SIC Code(s) (if known): Brief description of business activities (Production / Manufacturing Operations): Description of operations generating wastewater (discharged to sewer,hauled or evaporated): Estimated volume of industrial wastewater to be discharged (gal / day): List hazardous wastes generated (type / volume): Date operation began/or will begin at this location: Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority? Yes No If yes, when: Site Contact Title Signature Phone No. ENCINA WASTEWATER AUTHORITY,6200 Avenida Encinas Carlsbad, CA 92011 (760) 438-3941 FAX:(760) 476-9852