Loading...
HomeMy WebLinkAbout2870 Whiptail Loop; ; CBC2018-0512; Permit(city of Carlsbad Commercial Permit Print Date: 12/03/2018 Permit No: CBC2018-0512 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 2870 Whiptail Loop BLDG-Commercial 2091201000 $245,600.00 Work Class: Cogen Lot#: Reference #: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Description: WHIPTA!L: 187.3KW ROOF MOUNT PV SYSTEM, 614 MODS, 3 INVERTERS BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) S81473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-COMMERCIAL Total Fees: $2,024.D8 Owner: AP G CARLSBAD I LLC 1010 Coast Highway 101 S C/0 Raf Pacifica Group (SlConb), 103 ENCINITAS, CA 92024 Total Payments To Date: $2,024.08 Status: Applied: Issued: Permit Finaled: Inspector: Final Inspection: Contractor: EVA GREEN POWER INC 5927 Balfour Ct, Ste 213 Carlsbad, CA 92008-7377 760-279-8890 Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Closed -Finaled 09/07/2018 10/16/2018 12/3/2018 3:40:39PM $0.00 $1,144.3D $801.01 $1D.OO $68.77 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f \ www.carlsbadca.gov • • THE fO:.i..-'\JWlNG APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: •PLANNING •ENGINEERING QBUILOING •FIRE QHEALTH •HAZMATIAPCO I { City of Building Permit Application Plan Check No. /'A/'~ I 9-,") '1 ") 1635 Faraday Ave .. Carlsbad, CA 92008 Est. Value 41 ,..,,_ /_00...::., . Carlsbad Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Deposit email: building@carlsbadca.gov Date Q /7 ff;>{ www.carlsbadca.gov JOB ADDRESS SUITE#/SPACE# /UNIT# I APl'f , 2870 Whiptail Loop Carlsbad CA 92010 209 -120 -10 - CT/PROJECT II I LOT# I PHASE# I# OF UNITS I# BEDROOMS # BATHROOMS lTENANTSUSINESS NAME 1CONSTR. TYPE I occ. GROUP DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) THE PROJECT ENTAILS THE INSTALLATION OF A SOLAR PHOTOVOLTAIC SYSTEM AT 2870 W WHIPTAIL LOOP, CARLSBAD, CA, 92008. THE SOLAR SYSTEM WILL CONSIST OF (614) SOLAR PV MODULES, (3) GRID INTERACTIVE STRING INVERTERS, AND A SYSTEM SIZE OF 187.3kW DC(STC). THE SYSTEM WILL BE LIMITED BY THE FULL LOAD OUTPUT OF THE INVERTERS OF 150KVA SOLAR. THE SOLAR PV ARRAY WILL BE INSTALLED ON THE EXISTING BUILDINGS FLAT ROOF. THE PV SYSTEM WILL BE INTERCONNECTED LINE SIDE AND WILL BE INSTALLED PARALLEL WITH THE UTILITY POWER GRID UNDER A VIRTUAL NET METERING ARRANGEMENT. EXISTING USE l PROPOSED USE I GARAGE (SF) PATIOS (SF) ·1 DECKS (SF) FIREPLACE !AIR CONDITIONING l FIRE SPRINKLERS YES0, No• YES•No• YES•,o• APPLICANT NAME Miranda Goar PROPERTY OWNER NAME SR22 Carlsbad Oaks Distribution, LLC; A~ Prlmarv Contact ADDRESS ADDRess "bl' C<>,lsi,.,:11, 1.1.c.. rie IVC QA\(' 5927 Balfour Court Suite 213 111 C Street, Suite 200 LL.(.. CITY STATE ZIP CITY STATE ZIP Carlsbad CA 92008 Encinitas CA 92024 PHONE IFAX PHONE I"" 707-332-9625 858.314.3116 EMAIL Miranda@EVAGreenPower.com EMAIL george@rafpacificagroup.com DESIGN PROFESSIONAL Miranda Goar CONTRACTOR BUS. NAME EVA Green Power INC ADDRESS ADDRESS 5927 Balfour Court Suite 213 5927 Balfour Court Suite 213 CITY STATE ZIP CITY STATE ZIP Carlsbad CA 92008 Carlsbad CA 92008 PHONE [FAX PHONE !FAX 707-332-9625 858-344-293 EMAIL MirandalNlEVAGreenPower.com EMAIL Antonio@EVAGreenPower.com IST"' UCE-21823 STATE LIC.# I CLASS l "sL°r~Ro'o2899-o3-2018 101071 C-10 (Sec, 7031.5 Business and P_rofess1ons Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such per_mit to file a si.e:ned statement that he is licensed pursuant to the provisions of the Contractor's License LawJChapter 9, commending with Section 7000 of 01vis1on 3 of the Business and Professions Code) or That he is exempt therefrom, and the basis for the alleged exemption. Any v1o(ation of Section 031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)) . • Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: D I have and will maintain a certificate of consent to self-insure for workers· compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued D I have and will maintain workers' compensation. as reQuired by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance earner and policy number are: Insurance Co. _____ ---''":::"::_'::':::m,::":::"':::":.:"::_" Ic."'cc".::'":::":.:'_::"':::''------Policy No _____ _::92:::22:.:"::_2cc°'_' _____ Expiration Date ___ _c":.:I12::':_°":__ __ _ This section need not be completed if the permit is for one hundred dollars ($100) or less. D Certificate of Exemption: I certify that in the performance of the work for which this permit Is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars {&100,000), in addition to the cost of compensation, damages as rovided for In S n 3706 of the L or code, interest and attorney's fees. ~ CONTRACTOR SIGNATURE I hereby affirm that I am exempt from Contractor's License Law for the following reason: • 0 • I, as owner of the property or my employees with wages as their sole compensation, will do the work and the strucrure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner.builder will have the burden of proving that he did not build or improve for the purpose of sale) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec, 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) I am exempt under Section ____ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Oves 0No 2. I (have/ have not) signed an application for a building permit for the proposed work 3.1 have contracted with the following person {firm) to provide the proposed construction (include name address/ phone/ contractors' license number): 4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address I phone/ contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address/ phone/ type of work): ~ PROPERTY OWNER SIGNATURE f.~r__,,<//.~ George Aquino, Property Manager •AGENT DATE 9.6.18 ... Is the applk:ant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 Yes O No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? • Yes • No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? :J Yes O No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES ANO THE AIR POLLUTION CONTROL DISTRICT. I certify that I have read the application and state that the above information is correct and that the infonnation on the plans is accurate. I agree tocomplyVJith all City ordinances and State laws relating to building construction. I hereby authorize representative of !he City of Carlsbad to enter upon the above menboned property for inspection purposes, I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES. JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: NI OSHA permit is required for excavations over s·o· deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permrt issued by the Building Official under the provisions of this Code shall expire by limitaton and become null and void if the building or work authorized by suc/1 permit is not commenced within 180 days from the date of such permrt or iflhe building or work authorized by such perm rt is suspended or abandoned at any time after the won( is commenced for a period of 180 days (Section 106.4.4 Unifoon Building Code) . .@S' APPLICANT'S SIGNATURE \\iv,~ ~ •ATE 09/04/2018 . PERMIT INSPECTION HISTORY REPORT (CBC2018-0512) Permit Type· BLOG-Commercial Application Date: 09/07/2018 Owner: A P G CARLSBAD I LLC Work Class Cogen Issue Date: 10/16/2018 Subdivision: Status: Closed -Finaled Expiration Date: 06/03/2019 Address: 2870 Whiptail Loop Carlsbad, CA 92010-6710 IVR Number: 13757 Scheduled Actual Inspection Type Date Start Date Inspection No. Inspection Status Primary Inspector Re inspection Complete 11128/2018 11/28(2018 BLOG-36 Solar 077171 •2018 Partial Pass Andy Krogh Reinapection Incomplete Panel Checklist Item COMMENTS Passed BLDG-Building Deficiency Partial as noted on card No 12/03/2018 1210312018 BLOG-36 Solar 077652-2018 Passed Andy Krogh Complete Panel BLDG-Final 077653-2018 Passed Andy Krogh Complete Inspection Checklist Item COMMENTS Passed BLDG-Structural Final Yes BLDG-Electrical Final Yes December 03, 2018 Page 1 of 1 DATE: 10/16/2018 JURISDICTION: CARLSBAD PLAN CHECK#.: CBC2018-0512 ✓• EsG1I A SM·'Ebrnlt Company SET: II revisited PROJECT ADDRESS: 2870 Whiptail Loop PROJECT NAME: Whiptail Rooftop PV system D )rPPLICANT "fo-JURIS [8J The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: [8J EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Date contacted: ~ Mail Telephone Fax In Person 0 REMARKS: By: Morteza Beheshti EsGil 10/16 email Telephone#: Email: Enclosures: 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 DATE: September 19, 2018 JURISDICTION: CARLSBAD PLAN CHECK#.: CBC2018-0512 ✓• EsG1I A )AH.budt Compary SET: I PROJECT ADDRESS: 2870 Whiptail Loop PROJECT NAME: Whiptail Rooftop PV system • APPLICANT p JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: D EsGil staff did not advise the applicant that the plan check has been completed. ~ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Miranda Goar ~.coatacteg_;__d: , /2.1 l1f (by~ Telephone Fax In Person By: Morteza Beheshti EsGil 9/11 Telephone#: 707.332.9625 Email:miranda @evagreenpower.com Enclosures: 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 CARLSBAD CBC2018-0512 September 19, 2018 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: CARLSBAD PREPARED BY: Morteza Bebesbti BUILDING ADDRESS: 2870 Whiptail Loop BUILDING OCCUPANCY: NA BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance 1997 UBC Buildin Permit Fee g ... 1997 UBC Plan Check Fee Type of Review: D Repetitive Fee ---;7 Repeats ~ Comments: 0 Complete Review • Other D Hourly EsGII Fee PLAN CHECK#.: CBC2018-0512 DATE: September 19, 2018 Reg. VALUE ($) Mod. 245,600 245,600 D Structural Only >------<I Hr. @ • $698.0Sj Sheet 1 of 1 CARLSBAD CBC2018-0512 September 19, 2018 GENERAL 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring IllllQ corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. ELECTRICAL and ENERGY COMMENTS PLAN REVIEWER: Morteza Beheshti ELECTRICAL (2016 CALIFORNIA ELECTRICAL CODE) 1. "Arc-fault protection is required for DC circuits per CEC 690.11. Document how this protection is provided with your photovoltaic design." 2. Please provide for Rapid Shutdown function for this PV system. CEC 690.12 3. Please revise the section numbers and notes on the plans to match the 2014 National Electrical Code (NEC) and the 2016 California Amendments as adopted by California. 4. Please provide an AC disconnecting means for each inverter within sight of the inverter to be grouped with the DC disconnect. 5. Please demonstrate compliance with the CENTERLINE fire access and pathways and setback requirements FOR BOTH AXIS. Also show the 4' setback dimensions on plans around HVAC or other equipment requiring access and the perimeter of the roof. Do not install junction boxes or any obstacles in the above clear fire department passageways. 6. Please provide description for labeling of both service disconnecting means to be installed for following signage: "Service Disconnecting Means 1 of 2" (to be posted at the main service disconnect) and "Service Disconnecting Means 2 of 2" (to be posted at the PV backfeed disconnect). CARLSBAD CBC2018-0512 September 19, 2018 7. Service modification: Service to be NRTL laboratory UL field labeled prior to final inspection. 8. Describe, on the plans, the line side bus connection design. If a modification to the service is necessary, a NRTL field evaluation will be necessary and is required to be Noted on the plans. Note: If you have any questions regarding this Electrical and Energy plan review list please contact Morteza Beheshti at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. Structural Comments Plan Reviewer: Dwight Ashman 1. Please provide wind and seismic analysis to justify ballast block quantities. 2. Note on the plans that special inspection will be required per CBC Section 1705. 3. Please provide a ballast layout on the plans. Include ballast weight, and quantities. Note: If you have any questions regarding this Electrical and Energy plan review list please contact Dwight Ashman at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. Plan Check NO: CBC2018-0512 Project Name: Whiptail Rooftop PV System Project Address: 2870 Whiptail Loop, Carlsbad CA Response By: Miranda Goar P.E. ,.\Green WP•wer n r:: r r ·; 1, [~,". l ... r ~ · ' Plan Correction Response 0C1 O 1 2018 Electrical: Cl'i \ ', 1. Complied, per our phone conversation on 9/24/2018, SM.A?MJ~h'e~ ~ill protect DC circuits per CEC 690.11. Please see sheet E-400 for certificate of compliance. 2. Complied, per our phone conversation on 9/24/2018, all PV conductor lengths to Inverters are less than 10 feet per 690.12 (1). Please see sheet E-200 & E-201 to confirm length and conduit routing. Please also see note 3 on both E-200 & E-201 indicating the maximum PV Conductor length from the array to the inverter to be 10' -0". 3. Complied, please see sheet E-001 for Governing Code sections. 4. Complied, per our phone conversation on 9/24/2018, all inverters have integral AC & DC disconnects. Please see sheet E-400 for reference and inverter locations on E-200. 5. Complied, per our phone conversation on 9/24/2018, please see sheet E-202 for fire access pathways. 6. Complied, per our phone conversation on 9/24/2018, please see sheet E-600 Detail 3, 13, & 20. 7. Per our phone conversation on 9/24/2018, service will not be modified from original manufacture specifications. Please see bus tap design details and photo on sheet E-700. 8. Per our phone conversation on 9/24/2018, service will not be modified from original manufacture specifications. Please see bus tap design details and photo on sheet E-700. Structural: 1. Complied, please see manufacture supplied seismic and ballast block quantities in structural package. Calculations were also emailed on 10/1/18. 2. Complied, see sheet E-001 general note number 19 for special inspection requirements. 3. Complied, please see manufacture ballast weight, quantities, and layout in structural package. Calculations were also emailed on 10/1/18. TE,£NGIN££RING 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 PHONE NO: (949) 305-1150 STRUCTURAL CALCULATIONS RECEIVED OCT O 1 2018 FOR CITY or: C,<.HLS8/\D BUILDING Di\iiSION EVALUATION OF (E) ROOF TO SUPPORT SOLAR PV ARRAYS 2870 Whiptail Loop East Carlsbad, CA 92010 PREPARED FOR: EVA Gereen Power 5927 Balfour Court, Suite 213 Carlsbad, CA 92008 4STEL ENGINEERING PROJECT NO. 18-1164 9/5/2018 2091201000 10/1/2018 CBC2018-0512 ~j .. IEl£NGIN££RING -f Sheet of Client EVA Gereen Power Job No. 18-1164 Project 2870 Whiptail Loop East, Carlsbad, CA 92010 Date 9/5/18 ___:R_:_O::.O.::..;_FT-'-O.::..;_P_:_P_;V_;E::.V.:..;A_;;L::.:U::.:A..:.T:...:IO=N'--________________ Engineer __ 4.;_S::.T:..:E::.:L:..__ Structural Evaluation of Existing Roof Structure to Support Proposed Roof Top PV Arrays The following presents the results of the evaluation of the capacity of the roof structure at the existing building located at 2870 Whiptail Loop East, Carlsbad, CA 92010, to support additional loads from the proposed roof mounted PV system . The added loads evaluated include gravity, wind and seismic loads in accordance with the current California Building Code (CBC) and the provisions of ASCE 7-10. The adequacy of the existing roof is evaluated based on sections 403.3 and 403.4 of the 2016 California Existing Building Code (CEBC) for added gravity, and lateral wind and loads seismic respectively to existing buildings. The existing building is a one story structure with a total roof area approximately 97,920 sq. ft. The existing construction consists of precast concrete "tilt-up" exterior walls and panelized wood roof supported by open web steel joist purlins and open web steel girder trusses. The roof acts as a horizontal diaphragm transferring tributary lateral wind and seismic forces to the exterior and interior concrete shear walls that transfer the lateral loads to the foundations. CEBC Section 403.3 allows up to 5% of existing gravity loads to be added to existing buildings without having to evaluate or strengthen existing supporting structural elements. Gravity loads include both dead and live loads. Roof live loads can be omitted where low profile PV solar panel systems are mounted within 2'-0" of the roof surface such as the Pro Solar racking system with 10 degree tilt shown on the PV System drawings. The minimum building code (CBC) prescribed roof load varies between 20 psf and 12 psf for roof members depending on the tributary roof area supported. The superimposed weight of the proposed PV system including PV modules and racking system averages 6.4 psf. The added PV array dead load to the building roof is less than the original design roof live load over the same area, therefore the additional PV system weight will not increase the gravity loads to the existing roof elements. CEBC Section 403.4 allows alterations to existing buildings to increase seismic lateral loads by no more than 10% without having to evaluate or strengthen existing seismic lateral load resisting structural elements. The seismic lateral loads resisted by building lateral load resisting elements are based on the tributary building weight. The following calculations compare the additional weight of the proposed roof mounted PV system including PV modules and racking to the existing tributary seismic weight to the roof level in each major direction. The weight of the proposed roof top PV system increases the lateral seismic loads tributary to the roof diaphragm maximum 7.35% in the North-South direction which is less than the 10% limit prescribed by CEBC section 403.4. ( .6 SIFlifENG/NEERING Sheet of Client EVA Gereen Power Job No. 18-1164 Projec 2870 Whiptail Loop East, Carlsbad, CA 9201 O Date 9/5/18 --'K-"E=-Y'-'-P.::LA:....;;_;N.::S'-________________________ Engineer 4STEL Ov.PHRAGM D -F ROOF LEVELOVERALL KEY PLAN I NHI----L~--11 I I ,....,. __ -• J_ E_ -+- I I I 11 I m LH----.------+- : I : ...,. ___ ...L_ __ ....... _1--1-- 1 ~ I I I I I -ra_l_ I 8cb- DIAPHRAGM F -; DIAPHRAGM A -D OVERALL SITE PLAN ( j STE•ENGINEERING Sheet of Client EVA Gereen Power Job No. 0 Projec 2870 Whiptail Loop East, Carlsbad, CA 92010 Date 9/5/18 • • • • , , I _K_E_Y_P_L_A_N_S _________________________ Engineer __ 4S_T_E_L_ ROOF LEVEL DIAPHRAM A ~ D KEY A 44'-o" ~ "' C 120'-4" .. .. • . .. l~· h 1&5•-4• I I I I I I T I I 7 7 --. --. 7 ~ I I I I I I 7 7 --. --. 7 I s·-o· I I 7 r I I I I I I I I r I I r ~ • it C8J C8 C8:I C8J I I I r I I I I . r I I I r I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I --. --. 7 C8:l (8 C8:I C8J I I I I I I I I I I I I I ' I l l I 1 T I I I I I I I I I I ~ I I I I I r I I I I I I I I I I I I l I I T I I I --r I ,. I I I I I I I I I I I I I I I I I I I· I I I I I I I I I I I II I I I I I I I I I I I . "t 'lo C8l (8 C8:I C8J • - I~~ lo ~--' ~ ~ OFFICE AREt "\ ~~ " "-"-~ ~"" ~ ·,, ~~" I~ -~~ . 59'-4" L, . -' " 105•-0· ~ ~ 9 81 ,:. PARTIAL ROOF FRAMING PLAN -DIAPHRAGM A -D SCALE: 1/32"•1"-o" u I. • --. T I I I I --. T I I I I I I I I I I C8J r I I I I I I I I I I I I I I I I I I I I I I 1 r r I I I I I --r I ... I I --. I T ·i; I ~ C8l • I ,.., ,-.. ~ I I l I I I I I I 18) c5 ( A ~T'FIENGINEER/NG Sheet of Client EVA Gereen Power Job No. 18-1164 Projec 2870 Whiptail Loop East, Carlsbad, CA 92010 Date 9/5/18 _N:..:...c•S=--=Lc:a.:.:te"-r.:.al'-S:c.e::.;i.:.sccmc.ic:;_;_A::.;nc:a"ly.:.s:.::is..:B::.;e::.;tw=e.:.e.:.:n..:L:;;in-"e'-'s'-'A--"--.:.D _____________ Engineer _..:4..:S..:T.:.Ec:L_ ROOF LEVEL TRIBUTARY SEISMIC LOADS• N-S LATERAL A-D Existing Roof Dead Loads: Warehouse ................. 13.0 psf Office ................... 17.0 psf Original Drawings by Ware Malcomb Commercial Real Estate & Wiseman+ Rohy Structural Engineers dated March 17th, 2016 labeled "Plan Check" Existing Roof Dead Load For Dlaphram Area Between Lines A -D Warehouse Roof Area, A• = (164' x 152') -1409 (sq.ft) = Office Roof Area, A. = (164' x 43') -0 (sq.ft) = 23,543 (fl') 7,092 (fl') Total Roof Dead Load, WoR = D• X A.= 426.627 (lbs) Existing Exterior Wall Load Tributary to Roof Overall Ext. North Wall Height Above Finished Floor, Overall Ext. South Wall Height Above Finished Floor. South Wall Mezzanine Height Above Finished Floor, Hw,N = Hw,s = HM,S;:;; HR.N = HRs = 40.00 (ft) 39.00 (ft) 13.50 (ft) 38.29 (ft) 33.02 (ft) Average North Roof Height, Average South Roof Height, North Tributary Exterior Wall Height, South Tributary Exterior Wall Height, North Concrete Wall Weight, Hrw.N = Hw2 / (2.HR,N) = 20.89 (ft) Wall Openings: South Concrete Wall Weight, South Curtain Wall Weight, North Concrete Walls Length, South Concrete Walls Length, South Curtain Wall Length, Hrw.s = (Hw.s-HM,.)' / (2.(H.,s-HM,s)) = 16.66 (ft) WcN = 150 (pcf) x 10.00 (in)= 125.00 (psf) Wes= Wcws = Lw,N = Lw,s = Lcw.s = 150 (pcf} X 10.0 (psi) 145.00 (ft) 105.00 (ft) 58.32 (ft) 8.00 (in)= 100.00 (psf) Number of Windows= 5 Area of Window= 45.00 (sq. ft.) Centroid of Windows from Mezzanine = 6.50 (ft) Total Tributary Area of Opening to Roof= -74.92 (sq. ft.) Number of Large Openings= O Area of Window= 139.27 (sq. ft.) Centroid of Window Area above Mezzanine= 4.75 (ft) Total Tributary Area of Opening to Roof= 0.00 (sq. ft.) North Tributary Wall Weight to Roof, WWR,N = WcwX Hrw,N x Lw,N = 378,689 (lbs) South Tributary Wall Weight to Roof, WWR,s = WcwX Hrw,s x Lw,s = 184,527 (lbs) IWw• = 563.216 /lbs) Existing Seismic N-S Load Tributary to Roof Diaphragm WER,IA•DJ = Wo• + IWw• = 989.843 libs) WER,A = w ••. o= 0.5 x WER,(A•D] = 494.922 libs) Weight of Roof Top PV Arrays betw. Lines A -D, Wpv = PV Area x PV Weight PV Area = 9804 sq, ft. PV Weight = 6.4 (psi) --~--'--'----"£ W PV = 62,914 (lbs) Centroid of Wev from Line 'D', Xpv = 69.4 (ft) Distance betw. Shear Wall Lines A-D, L(2-,I = 164.3 (ft) Tributary Weight of PV Arrays to Roof Wall Line A, WPV,2 = 'i.WevX (Xevl L(A-01) = Wall Line D, Wev.3 = 'i.WPV X (1 -Xev / L(A-oil = At Line A, At Line D, [ Wpv,A / WER,A] = 26,561 / 494,922 = [ Wpv,o / WER,o] = 36,353 / 494,922 = 5.37% 7.35% 26,561 (lbs) 36,353 (lbs) < 10% per CEBC Section 403.4 < 10% per CEBC Section 403.4 OK OK ( j ST'Fl£NGINE:£R/NG Sheet of Client EVA Gereen Power Job No. 0 Projec 2870 Whiptail Loop East, Carlsbad, CA 92010 Date 9/5/18 _K...;.E:....Y_..;..P.;;;L:....A...;.N...;.S _________________________ Engineer _4_S_T_E_L_ ROOF LEVEL DIAPHRAM D-F KEY c. 120'-4" 0 E 100'--0" F 100•-oM G i. , I I I I I I I I I ' I I I I I I I I I I I I I I I r I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I ~ igi 181 181 ZJ lZl 181 181 I I I I ' T T ' I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I ' ' T 1 I I I I I r I I I I I I I -r , T T I I ' I ' l I I I I I I I I I I I I I I I I I l I I ':o C8J ~ C8J I I I I I I I I • I ;; IZI 181 n " [2s) cg:) - I I I I I I I I I I T ' T 1 I l I I I I 1. I I I 'I ' T T I l I I I I I I I I I I r I I I I I r I I I l I I I I I I I I I I I I I l cg:) ~ cgj ;;: IZI 181 ~~.~ '"''' ' ,1 OFFICE AREA I" ... ' ' ' ' " " ~ ~~~ .. ' h ~ I ' ~ N G ... ... ~ " ' 1os·-o· 10( -0" C ~ .. r $ l•ORTI-1 PARTIAL ROOF FRAMING PLAN-DIAPHRAGM 0 -F Sheet of ---=E=-V:..:A..:....:G:..:e::..re:cce:..:n:...P:...o=-w::..e:ccr;__ ______________________ Job No. 18-1164 Projec 2870 Whiptail Loop East, Carlsbad, CA 92010 Date 9/5/18 _N;_;_c-S;;....;;;L;;;.at.;.;e::..ra:..:lc...S=-e:..:i.c.sm=ic:...Ac.c..:n:..:al:.,.ys.c.i::..s...;B:..:e:..:tw=e-'-e"n-'L"'in-"e"s'-Dc.._-:...F _____________ Engineer __ 4:..:S:..T:..:E:::L=-- ROOF LEVEL TRIBUTARY SEISMIC LOADS -N-S LATERAL D -F Existing Roof Dead Loads: Warehouse ................. 13.0 psf Office ................... 17.0 psf Original Drawings by Ware Malcomb Commercial Real Estate & Wiseman + Rohy Structural Engineers dated March 17th, 2016 labeled "Plan Check" Existing Roof Dead Load For Dlaphram Area Between Lines D -F Warehouse Roof Area, AR = (100' x 137') 0 (sq.ft) = Office Roof Area, A• = (100' x 36') -0 (sq.ft) = Total Roof Dead Load, Wo• = D• X Ao = Existing Exterior Wall Load Tributary to Roof Overall Ext. North Wall Height Above Finished Floor, Overall Ext. South Wall Height Above Finished Floor, South Wall Mezzanine Height Above Finished Floor, 239.846 {lbs) Hw,N = 40.00 (ft) Hw,s = 39.00 (ft) HM,S = 13.50 (ft) HR,N = 38.29 (ft) HR,S = 34.32 (ft) 13,742 (ft2) 3,600 (fl') Average North Roof Height, Average South Roof Height, North Tributary Exterior Wall Height, South Tributary Exterior Wall Height, North Concrete Wall Weight, Hrw,N = Hw2 I (2.HR,Nl = 20.89 (ft) Hrw,s = (Hws-HM,s)2 I (2.(Ha.s-HM_s)) = 15.62 (ft) Wcw = 150 (pcf) x 10.00 (in)= 125.00 (psi) South Concrete Wall Weight, Wcw = 150 (pcf) x 8.00 (in)= 100.00 (psi) North Concrete Walls Length, Lw,N = 100.00 (ft) South Concrete Walls Length, Lw,s = 100.00 (ft) Wall Openings: Number of Windows = 5 Area of Window= 45.00 (sq. ft.) Centroid of Windows from Mezzanine= 6.50 (ft) Total Tributary Area of Opening to Roof= -70.24 (sq. ft.) Number of Large Openings= Area of Window= 139.27 (sq. ft.) Centroid of Window Area above Mezzanine = 4. 75 (ft) Total Tributary Area of Opening to Roof= -31.77 (sq. ft.) North Tributary Wall Weight to Roof, WWR.N = Wcw x HTW,N x Lw,N = 261,165 (lbs) South Tributary Wall Weight to Roof, WwR,s = WcwX H,w,s x Lw,s = 156,262 (lbs) Existing Seismic N-S Load Tributary to Roof Diaphragm Total Existing Seismic Force= We•.10-,1 = Wo• + IWw• = Seis Force to Line D and F = WER,D = WeR.F= 0.5 x WER,ID-FJ = IWWR = 417,427 {lbs) 657.273 {lbs) 328.636 {lbs) Weight of Roof Top PV Arrays, Wpy = PV Area x PV Weight PV Area = 4645 sq. ft. PV Weight = _6_.4---"-(p_sf)_,_ __ _ r.w,v = 29,806 (lbs) Centroid of WPV from Line 'F', Xpv = 56.1 (ft) Distance betw. Shear Wall Lines D -F, L10..,) = 100.0 (ft) Tributary Weight of PV Arrays to Roof Wall Line D, WPv,D = 'r.WevX (Xpv/ L10-d = Wall Line F, WPV,F = I.Wpv x (1 -Xpy / L(•-FJ) = At Line D, [ WPV,D I Weo,o I= 16,707 I 328,605 = At Line F, [ W,v,F I W, •. , J = 13,099 I 328,636 = 5.08% 3.99% 16,707 (lbs) 13,099 (lbs) < 10% per CEBC Section 403.4 < 10% per CEBC Section 403.4 OK OK (t STE•ENGINE£RING Sheet of Client EVA Gereen Power Job No. 0 Projec 2870 Whiptail Loop East, Carlsbad, CA 9201 0 Date 9/5/18 KEY PLANS Engineer 4STEL ___ _;;;;_.;;..;..;;.._ ________________________ _ ROOF LEVEL DIAPHRAM F -H KEY .. 100'-Q" • 1 oo·--0· " H 100·--0" ' ~ .. . • - I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I r::8l I I I I I I I I I I 1:8) 1:8:1 C8l C8l IZl C8l I I I I I I I I I I I I I I I I I I I C8] I I I I I I I I I I I I I I I ' I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I J I 81 l8l I I I ' I J I ll 7 C8l 181 cg) cg:) 181 2$1 IZl 'o ' -""'""'"" ,, "' LO ' - "," '·, ~ 1~"'-~ ' ,~ICE AREA~· """ . ..... I -N 0 It J ~ 10( -0" ' , . . f F $ NORTtt PARTlAL ROOF FRAMING PLAN• DIAPHRAGM F -H (; <7'E'IENGINEER/NG Sheet of Client EVA Gereen Power Job No. 18-1164 Projec 2870 Whiptail Loop East, Carlsbad, CA 92010 Date 9/5/18 _N'-'--'-S'---"L"'at-'-'e"-ra"l'-S'--e'--i-'-sm=ic'--A'--'-'n"'al"-y-'-s1"·s---'B'--e'--tw-'-"'e-'-e'-'n--'L"'in-"ec..:s;.;Fc.-..;Hc,.;.... _____________ Engineer 4STEL ROOF LEVEL TRIBUTARY SEISMIC LOADS -N-S LATERAL F -H Existing Roof Dead Loads: Warehouse ..... ............ 13.0 psf Office ................... 17.0 psf Ortginal Drawings by Ware Malcomb Commercial Real Estate & Wiseman+ Rohy Structural Engineers dated March 17th, 2016 labeled "Plan Check" Existing Roof Dead Load For Dlaphram Area Between Lines F -H Warehouse Roof Area, A• = (100' x 117') 0 (sq.fl) = Office Roof Area, A• = (100' x 34') -0 (sq.fl) = Total Roof Dead Load, W0• = D• x Ao = 211.143 {lbs) Existing Exterior Wall Load Tributary to Roof Overall Ext. North Wall Height Above Finished Floor, Hw,N = 40.00 (ft) Overall Ext. South Wall Height Above Finished Floor, Hw,s = 39.00 (ft) South Wall Mezzanine Height Above Finished Floor, HM,s = 13.50 (ft) Average North Roof Height, HR.N = 38.29 (ft) HR,S = 34.32 (ft) 11,742 (ft2) 3,441 (fl') Average South Roof Height, North Tributary Exterior Wall Height, South Tributary Exterior Wall Height, North Concrete Wall Weight, Hrw,N = Hw2 / (2,HR_N) = 20.89 (ft) Wall Openings: Hrw,s = (Hw_s-HM_s)2 / (2.(H.,s-HM,s)) = 15.62 (ft) Wcw = 150 (pcf) x 10.00 (in)= 125.00 (psf) South Concrete Wall Weight, Wcw = North Concrete Walls Length, Lw,N = South Concrete Walls Length, Lw,s = 150 (pcf} X 100.00 (fl) 100.00 (ft) 8.00 (in)= 100.00 (psi) Number of Windows= 5 Area of Window= 45.00 (sq. ft.} Centroid of Windows from Mezzanine = 6.50 (ft) Total Tributary Area of Opening to Roof= -70.24 (sq. ft.} Number of Large Openings= 1 Area of Window= 139.27 (sq. ft.} Centroid of Window Area above Mezzanine = 4.75 (ft) Total Tributary Area of Opening to Roof= -31.77 (sq. ft.} North Tributary Wall Weightto Roof, WwR,N = WcwX Hrw,N x Lw,N = 261,165 (lbs) South Tributary Wall Weight to Roof, Wwo,s = Wcw x Hrw,s x Lw,s = 156,058 (lbs) Existing Seismic N-S Load Tributary to Roof Diaphragm Total Existing Seismic Force= WeR,IF-HJ = Wo• + IWWR = Seis Force to Line F and H = WER,F = WeR,H= 0.5 x WeR,[F-HJ = IWw• = 417.223 {lbs) 628.366 (lbsl 314.183 (lbs) Weight of Roof Top PV Arrays. W,v = PV Area x PV Weight PV Area= 3116sq.ft. PV Weight = 6.4 (psi) ___ ..;,_ ___ _ r,wPV = 19,993 (lbs) Centroid of Wpv from Line 'H', XPV = 58.3 (fl) Distance betw. Shear Wall Lines F -H, LI,-HI = 100.0 (ft) Tributary Weight of PV Arrays to Roof Wall Line F, WPV,F = rwPVx (Xpv/ L(F-H)} = Wall Line H, Wpv,H = LWpv X (1 ~ Xpv / L(F-H)) = At Line F, At Line H, [WPV,F/WER,F)= 11,648/ 314,183 = I W,v,H I w••·" I= 8,345 / 314,183 3.71% 2.66% 11,648 (lbs) 8,345 (lbs) < 10% per CEBC Section 403.4 < 10% per CEBC Section 403.4 OK OK 111UNIRAC PROJECT TITLE: WHIPTAIL PROJECTID:6B1E23E9 U-BUILDER PROJECT REPORT RECE!'/Et) OCT O 1 2018 VERSION: 1.15.3 SEP 04, 2018, 10:26 PM Name: Eva Green Power C\TY OF Cf\:-~l_.<:'X:~/\~) Designedbyfanchondo1 5927 Balfour Ct. Suite 213 Carlsbad CA 92008 ue-~ I LU: i·,: G u: \/ l ;3 \UN AM-BALLASTED FLAT ROOF Address: City, State: Carlsbad, CA, 92008 616 305 Watt Panels Module: a-Cells a.PEAK BLK-G4.1 305 17606 tt2 305 Watts ENGINEERING REPORT Plan review Average PSF: Total weight on roof: -Bay weight: -Module weight: -Ballast weight: -Max Bay Load (Dead): Loads Used for Design -Bulldlng Code: -Wind Speed: -Ground Snow Load: -Roof Snow Load: -Seismic (Ss): -Elevation: -Wind Exposure: Loads Determined by Zip -City, State: -Wind Speed: -Ground Snow Load: 6.42 lbs/ft2 112989 lbs 29t6Ibs 25533Ibs 84540 lbs 225lbs ASCE 7-10 110 mph 0psf 0pst 1.15 51 tt C Carlsbad, CA 110 mph o psf 187.9 kWs Inspection RM-BALLASTED Product: FLAT ROOF Module Manufacturer: O-Cells a.PEAK BLK-G4.1 Model: 305 Module Watts: 305 watts Module Length: 65.77" Module Width: 39.37" Module Thickness: 1.26" Module Weight: 41.45Ibs Ballast Block (CMU) Weight: 30lbs 6 for north-most bays, Max Blocks per Bay: 4 for all others Building Height: 40 tt Roof Type: Other Parapet Height: >"" 2 ft CBC2018-0512 2870 WHIPTAIL LOOP Vvl-llPTAIL 1873KWROOF MOUNT PV SYSTEM. 614 MODS. 3 INVERTERS ~ ~ t ,...,--• i~<~ ~~:::J ~ . 2091201000 10/1/2018 CBC2018-0512 WORKSPACE 1 Average PSF: 6.07 lbs/112 Total Number of Modules: 393 Total KW: 119.9 KW Total Area: 11110ft2 Total weight on roof: 67451 lbs -Bay weight: 1782 lbs -Module weight: 16290 lbs -Ballast weight: 493801bs WORKSPACE 2 Average PSF: 7.00 lbs/ft2 Total Number of Modules: 138 Total KW: 42.1 KW Total Area: 4083 ft2 Total weight on roof: 28560lbs • Bay weight: 7001bs -Module weight: 57201bs -Ballast weight: 22140 lbs WORKSPACE 3 Average PSF: 7.03 lbs/ft2 Total Number of Modules: 85 Total KW: 25.9 KW Total Area: 2414 ft' Total weight on roof: 16977 lbs -Bay weight: 434 lbs -Module weight: 35231bs -Ballast weight: 13020 lbs Minimum Seismic Separation (Unattached Arrays)• • Array to Array: 5 in -To Obstruction or Parapet: 10 in • To Roof Edge {no Parapet}: 15 in Max Array Dimensions (Seismic) (For Unattached Arrays) • -NS: -EW: 170 ft 158 ft •in jurisdictions that follow SEAOC PV• 1 methodology. Minimum Seismic Separation (Unattached Arrays)• • Array to Array: 5 in • To Obstruction or Parapet: 10 in • To Roof Edge (no Parapet): 15 in Max Array Dimensions (Seismic) (For Unattached Arrays) • -NS: •EW: 147ft 137 ft •Jn jurisdictions that follow SEAOC PV-1 methodology. Minimum Seismic Separation (Unattached Arrays) • -Array to Array: 5 in • To Obstruction or Parapet: 10 in -To Roof Edge (no Parapet): 15 in Max Array Dimensions {Seismic) (For Unattached Arrays)• • NS: -EW: 152 ft 136 ft •in jurisdictions that follow SEAOC PV-1 methodology. RM10 Li-BUILDER PRODUCT ASSUMPTIONS RM1 0 -Ballasted Flat Roof Systems 1. Building and System Occupancy/Risk Category II 2. Building Height~ 60 ft. 3. Roof Slope> 2.4° (112:12) and< 5.6° (1-3/16:12) 4. Friction Tested Roofing Types: EDPM, PVC, TPO, and Mineral Cap 5. Required Setback from Module Edge to Building Edge for Wind Tunnel: 3 ft 6. Surrounding Building Grade: Level 7. Wind Design: Basic Wind Speed Range is 85-150 mph (ASCE 7-05) and 110-170 mph (ASCE 7-10). Wind Exposure: B or C (ASCE 7-05/ASCE 7-10). Occupancy/Risk Category II buildings and systems with a 25 year design life. Insertion of the project at-grade elevation can result in a reduction of wind pressure. If your project is in a special case study region or in an area where wind studies have been performed, please verify with your jurisdiction to ensure that elevation effects have not already been factored into the wind speed. If elevation effects have been included in your wind speed, please select Oft. 8. Ground Snow Load (ASCE 7·05/ASCE 7·10): 0·60 psf. Results are based on uniform snow loading and do not consider unbalanced, drifting, and sliding conditions. Roof snow load reduction calculated per Section 7.3 of ASCE 7 with the following assumptions: Exposure factor= 0.9, Thermal factor= 1.2. 9. RM1 0 Ballast Bay Weight: -3.5 tbs 10. Module Gaps (E/W) = 0.25 in 11. Seismic: Installations must be in seismic site class A, B, C, or Das defined in ASCE 7·05/ASCE 7·10 12. Ballast calculations are based on ASCE 7·05/ASCE 7· 1 0 load combinations and product specific wind tunnel testing. 13. Ballast Blocks: The installer is responsible tor procuring the ballast blocks (Concrete Masonry Units-CMU) and verifying the required minimum weight needed for this design. CMU to comply with ASTM standard specification for concrete roof pavers designation C1491 or C90 with an integral water repellant suitable for the climate it is placed. It is recommended that the blocks are inspected periodically for any signs of degradation. If degradation of the block is observed, the block should immediately be replaced. The CMU ballast block should have nominal dimensions of 4"x8"x16". The actual block dimensions are 3/8" less than nominal dimensions. Ballast blocks should have weight as specified for the project in the "Inspection" section of this report. 14. Limitations of Responsibility: It is the user's responsibility to ensure that inputs are correct for your specific project. Unirac is not the solar, electrical, or building engineer of record and is not responsible for the solar, electrical, or building design for this project. t 5. The system is certified to UL2703 when properly installed. See the installation guide for more detail. SEAOC PV1 ·2012: Structural Seismic Requirements and Commentary for Rooftop Soar Photovoltaic Arrays Assumptions for unattached photovoltaic arrays: 1. Importance Factor: Array (Ip)"' 1.0, Building (le) = 1.0 2. Site Class = D 3. S = design seismic displacement of the array relative to the roof 4. Minimum Separation: Array to Array= o.s-·s, Array to Roof Edge or Obstruction with Qualified Parapet= 1.0*S, Array to Roof Edge with Unqualified Parapet "" 1.5*S 5. s8 = mapped MCER, 5 percent damped, spectral response acceleration parameter at short periods per ASCE 7-05/ASCE 7-10 6. s0s = design, 5 percent damped spectral acceleration parameter at short periods per ASCE 7-05/ASCE 7·1 o 7. A minimum module return flange of 0.9in (when using 1-3/4 in. clip bolts) is required for all RM10 installations 8. A minimum module return flange of 0.65in (when using 2 in. clip bolts) is required for all RM10 installations 9. Coefficient of friction used for calculations per Unirac, fnc. Roof Mount Ballast Support Coefficient of Friction Testing report dated October 4, 2013. Roof pads are required for PVC, TPO, and EDPM roofs to attain a minimum coefficient of friction of 0.4. Mineral cap roofs do not require roof pads to attain a coefficient of 0.4. :11UNI RAC U-BUILDER PROJECT REPORT PROJECT TITLE: WHIPTAIL PROJECTID:681E23E9 Name: Address: City, State: Module: Eva Green Power 5927 Balfour Ct. Suite 213 Carlsbad CA 92008 U.S.A Carlsbad, CA, 92008 Q-Cells a .PEAK BLK-G4.1 305 305 Watts INSTALLATION AND DESIGN PLAN LAYOUT WORKSPACE 1 l J 1• 1 , ::I , Cl IJ •• ..1 Cl cJi l' ~ I I I I I I I I I I t I I I I I I ' I I 1-1 I " I I I t •I I 1_r-~1---r--[---------i--r•-u-r•--t•-•-tl---" (J _,_i),.tJ .', -t -• -• -,',....a--e-i!i-il,....a--e--e-i1,....i1i_,1i--e-m--il,....a--e-i!i-i1,....i1i--e--e-i1,....,1!!:!' -·' -~ • ·~ ~ -:-:-:-i>-~•-~-<--~••-<--~-~•-1(1-<'-~•-~-<--~••-<--:-:-:-:r· \-. -------------• ---••---•1-l•-----,,_ -1_, • I I I I I t f I I I I I I I I I -I I I •• .I t I I I I I I l j U l. ' ' l , J t r --·--• -~---- VERSION: 1.15.3 SEP 04, 2018, 10:26 PM Designed by fanchondo1 RM-BALLASTED FLAT ROOF 616 -305 Watt Panels 17606 ft2 187.9 kWs Note: Blocks above with values greater than 4 require extra ballast bays, except north-most bays which require extra bays for values greater than 6. The proper number of bays are provided in the Bill of Materials. The installer must install these extra bays as near to the indicated location as possible. Layout Dimensions NS Dimension: -74.5 ft EW Dimension: -247.6 ft Row Modules Bays Ballast Blocks (CMU) Ballast Weight 42 49 216 6480 2 42 47 180 5400 3 42 44 105 3150 4 42 44 103 3090 5 42 44 128 3840 6 28 44 154 4620 7 0 29 74 2220 8 31 38 170 5100 9 31 36 136 4080 10 31 34 84 2520 11 12 13 31 31 0 LAYOUT WORKSPACE 2 34 34 32 84 130 82 2520 3900 2460 [I J 1, [I '.1 ;f\. , '..I r1. '1 • I rY I, -1 I t -1 I I I I I I I I I I I I I I I -1 I I I I I I I I 1 1"1,I I I • I I I -I I I 1811-I I ·- fl 11!--•~ I --• ----r1---------4-1 --1•--['ll-----• ------•-,_, -•-I---~ {I--rw I -~-~-::1,:J~-·-I -•,_ • -r• _,•,-.;~. ~~-. -·-'·=•··-' -i'.;: •-r•,-~-"-~'!:. -· -· -I_, .. _ I -;:r\-~-I -' -'-;-'-~-· -~-= · -:::::1-;,-~·=~ •I --~-••-- •-~---- Note: Blocks above with values greater than 4 require extra ballast bays, except north-most bays which require extra bays for values greater than 6. The proper number of bays are provided in the Bill of Materials. The installer must install these extra bays as near to the indicated location as possible. Layout Dimensions NS Dimension: EW Dimension: Row Modules 46 2 46 3 46 4 0 LAYOUT WORKSPACE 3 Pfofld: 5b1t2let Array:WOfkspact 3 Bays 53 51 49 47 0 StmMNld comer blrJ' wllh CIIIJ block counl • -•11>.,.wllhCMIJblod<COIP ~16.2 ft ~253.1 ft Ballast Blocks (CMU) 230 202 192 114 11 12 1l 14 Ballast Weight 6900 6060 5760 3420 15 11 17 Note: Blocks above with values greater than 4 require extra ballast bays, except north-most bays which require extra bays for values greater than 6. The proper number of bays are provided in the Bill of Materials. The installer must install these extra bays as near to the indicated location as possible. Layout Dimensions NS Dimension: EW Dimension: Row Modules 17 Bays 24 ~25.9 ft ~93.5 ft Ballast Blocks (CMU) 114 Ballast Weight 3420 2 3 4 5 6 17 17 17 17 0 22 20 20 20 18 80 56 56 74 54 2400 1680 1680 2220 1620 The new high-performance module Q.PEAK-G4.1 is the ideal solution for all applications thanks to its innovative cell technology Q.ANTUM. The world-record cell design was developed to achieve the best performance under real conditions -even with low radiation intensity and on clear, hot summer days. 0 • • • LOW ELECTRICITY GENERATION COSTS Higher yield per surface area and lower BOS costs thanks to higher power classes and an efficiency rate of up to 18.6%. INNOVATIVE All-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low-light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti-Pl D Technology1, Hot-Spot-Protect and Traceable Quality Tra.Q™. EXTREME WEATHER RATING High-tech aluminum alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa) regarding IEC . MAXIMUM COST REDUCTIONS Up to 10 % lower logistics costs due to higher module capacity per box. A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year Ii near performance guarantee2. THE IDEAL SOLUTION FOR: -Rooftop arrafS on liliW ft!Stdenhal bu1ld1ngs Engineered in Germany Quality Tested • ·~---· .... ,..-it. • i.~ . ,.. ;n~u•~y, ✓,,, ... _'>I ~ .... ,o,,.:,c,c·"'~~ 10. >0032587 ( Ph(\1:0!1 ) .. -~--- Q CEllS Best polycry\lJllint solar module 2014 Q."'0•1.ZUS 1 APT test conditions: Cells at -1500V against grounded. with conductive me- tal foil covered module surface, 25°C, 168h ' See data sheet on rear for further information. Q CELLS MECHANICAL SPECIFICATION Format Weight Front Cover Back Cover Frame Cell Junction box 65. 7 in x 39.4 in x 1.26 ,n (1nclud1ng frame) (1670mm x 1000mm x 32mm) 41.45 lbs ( 18.8 kg) 0.13 in (3.2 mm) thermally pre-stressed glass with anti-reflection technology Composite film Black anodised aluminum 6 x 10 monocrystalline Q.ANTUM solar cells 2.60-3.03in x 4.37-3.54in x 0.59-0.75,n (66-77mm x lll-90mm x 15-19mm), Protection class IP67, with bypass diodes '"' ~ u.r111,o-1 f-t-t--lt.WCMO-i 1:u· ,,.,_ . , • I I •• ~ ..... -0.111"{4.,_) o---·-n.+rm, ••or=="""""-=1=. I • "·' ....... ~ 4 ,h......,.,-a(Ollliltil ........ ,:'i Cable Connector 4 mm2 Solar cable: (+) a:39.37 in (1000mm). (-) a:39.37 ,n (1000mm) Multi-Contact MC4 or MC4 intermateable, IP68 DfTAlt.AI.~~ o.tWuu-1 r'3J.o.»s'tes-, ELECTRICAL CHARACTERISTICS POWER CLASS MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC' (POWER TOLERANCE +SW /-OW) Power at MPP' P.,. (W] Short Circuit Curre11t• l,c [Al E Open Circuit Voltage• Voe [VJ :, E ·c Current at MPP' ,.,, [Al :i Voltage at MPP' v.,. [VJ Efficie11cy' '1 [%1 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NOC' Power at MPP' P.,. (Wl Short Circuit Curre11t• Open Circuit Voltage• Current at MPP' Voltage at MPP' [Al [VJ [Al [VJ 300 300 9.77 39.76 9.26 32.41 ~18.0 221.8 7.88 37.19 7.27 30.49 305 305 9.84 40.05 9.35 32.62 ~ 18.3 225.5 7.94 37.46 7.35 30.67 11ooow1m1, 2s•c, spectrum AM 1.5G 1 Measurement tolerances STC :t.3%: NOC .t: 5% '800W/m1, NOCT, spectrum AM 1.5G • typical values, actual 11alues may differ Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98 o/o of nominal power during first year. Thereafter max. 0.6% degradation per year. At least 92.6% of nominal power up to 10 years. At least 83.6% of nominal power up to 25 years. All data within measurement tolerances. Full warranties m accordance with the warranty terms of the Q CELLS sales organization of your respective country. .. .,. IARAOIA/IIC£ tW/ln1I SI-Glllf~.-... .,.,,t .. Jcw.,_l(ll'V-"""'IN,.,.,_.,,_,_~,ty..,zol•i'llM S--201•1 Typical module performance under low irradiance cond1t1ons m comparison to STC conditions (25°C, 1000W/m2). TEMPERATURE COEFFICIENTS Temperature Coetticie111 of lsc Temperature Coetticie11t of P • ., a V PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage v,,. [VJ Maximum Series Fuse Ratin1t [A DC] Oesign load, push (UL)' [lbs/ft21 Design load, pull (UL)' [lbs/112) [%/Kl [%/Kl +0.04 -0.39 1000 (IEC) / 1000 (UL) 20 75 (3600Pa) 55.6 (2666 Pa) Temperature Coefficient of Voe Normal Operating Cell Temperature Safety Class Fire Rating Permitted module temperature on continuous duty 2 see installation manual QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION UL 1703; VOE Quality Tested: CE-compliant: IEC 61215 (Ed.2): IEC 61730 (Ed.l ) apphcation class A CE @~ C c-,1_.US U~l,O, 1/$,IIUI Number of Modules per Pallet Number of Pallets per 53' Container Number of Pallets per 40' Container Pallet Dimensions ( L x W x H ) Pallet Weight p NOCT [%/Kl [°FJ -0.28 113 ±5.4 (45 ±3°Cl II C (IEC) / TYPE I (UL) -40°F up to +185°F C-4o•c up to +85°C> 32 30 26 68.71n x 45.3in x 46.l 1n (1745mm x 1150mm x 1170mm] 14351bs (651 kg) NOTE: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further mformation on approved installation and use of this product. Hanwha Q CELLS America Inc. 300 Spectrum Center Drive, Suite 1250. Irvine. CA 92618. USA I TH +l 949 748 59 961 EMAIL inqu,ry@us.q-cells.comIWEB www.q-cells.us Cost-Effective • Floor-mounted device eosy to install • No DC fuses required • Integrated DC disconnecter • ·• Highly Integrated • Integrated Wi-Fi access with any mobile device • 1 2 direct string inputs reduce labor and material costs • AC/DC overvohoge protection (optional) SUNNY TRIPOWER COREl Stands on its own 1111 Fastest Installation • Fast grid connection due to easy inverter configuration and commissioning • Completely accessible connection areas • Maximum Yields • Up to 150% DC:AC ratio • Six independent MPP trackers guarantee optimal energy production for every use, even in shading The Sunny Tripower CORE l is the world's first free-standing string inverter for decentralized rooftop and ground-based PV systems as well as covered parking spaces. The CORE l is the third generation in the successful Sunny Tripower product family and is revolutionizing the world of commercial inverters with its innovative design. SMA engineers developed on inverter that combines a unique design with an innovative installation method to significantly reduce installation time and provide all target groups with a maximum return on investment. From delivery and installation to operation, the Sunny Tripower CORE l generates widespread savings in logistics, labor, materials and services. Commercial PV installations ore now quicker and easier to complete than ever before. BLOCK DIAGRAM STP 50-40 DC-loodb,eok I Switch ~'--,o -jMPPTII L M.-j 2>~ 1 Wlfi I Po,1 ""°"""Stolt bbr ·~ .... 0 ll L2 L3 N PE -, .. -Communication Unit "'E ~ . E 0 -Q .. I .. --,, :::, .. .l.. --,. .. ~ " 0 jl ~ z 9, )( z io'--'<I l Power Unit 4, 0C-Over¥Otoge ~ AC-OvoM>~oge : :=: I MPPI 61 Protection Type II .,_ "r' Technical Data Input (DC) - Mox. generator power Mox. input voltage ·:.r.-· MPP voltage range / roted input voltage Min. input voltage / start input voltage Max. operating input current/ per MPPT Mox. short circuit current per MPPT / per string input Number of independent MPPT inputs/ strings per MPP input Output (AC) Roted power (at 230 V, 50 Hz) Mox. apparent AC power AC nominal voltage AC voltage range AC grid frequency/ range Roted power frequency/ roted grid voltage Mox. output current / Rated output current Output phases/ AC connection Power factor at roted power/ Adjustable displacement power factor THD Protective devices lnput•side disconnection device Ground fault monitoring / grid monitoring DC reverse polarity protection / AC short-cir- cuit current capability/ golvonicolly isolated Al~pole sensitive residuokurrent monitoring unit Protection class (according to IEC 62109.1) / overvoltoge category (according to IEC 62109•11 AC/DC surge orrester (Type II) Efficiency Curve Sunny Tripower COREl 75000Wp STC IOO0V 500 V to 800 V / 670 V 150 V / 188 V 120 A/ 20 A JOA/ 30A 6/2 50000W 50000VA 220 V / 380 V 230 V / 400V 2AO V / 415 V 202 V to 305 V 50 Hz/ A4 Hzto55 Hz 60 Hz/ 54 Hz to 65 Hz 50 Hz/ 230 V 72.5 A/ 72.5 A 3 / J.(N).PE I / 0.0 leading to 0.0 logging <3% • •!• •!•/- • I / AC: Ill; DC: II 0/0 100,-7--:----;---71mtl!l!JI 98 96 ~ 94 g ./ / I I .~ ffi 92 90 88 86 00 .. ~···~··--. --........ : .... : .... '.':'" -. •••·•••• ........ -••• 1 08 Eta (V.., • 500 VI E10 (V,., • 670 V) E10 IV.· 800 VI 97~ ,. 500 800 0.2 04 0.8 10 Oulput power/ Roled power www.SMA-Solar.com Technical Data Efficiency Mox. efficiency/ European efficiency General data Dimensions (W /H/D) Weight Operating temperature range Noise emission (typical) Self<onsumption (at night) Topology/ Cooling concept ·: .. c Degree of protection (as per IEC 60529) Climatic category (according to IEC 60721-3-4) Mox. permissible value for relative humidity (non<ondensing) Features / functions / accessories DC connection / AC connection Mounting feet LED indicators (status/ fault/ communication) Interface: Ethernet / WLAN / RSA85 Doto interface: SMA Modbus / SunSpec Modbus / Speedwire, Webconnect Multi-Function relay / Expansion Module Slots OptiTroc Global Peak / lnt"llroted Plant Control/ Q on Demond 24/7 Off-grid copoble / SMA Fuel Save Controller compatible Guarantee: 5/10/15/20 years Certificates and permits (more available on request) • Does nOI apply to ell notional oppendic1t1 of EN 50438 Pro1ec1ion Type II ::: ~: optional Sunny Tripower COREl 98.1 % / 97.8% 621 mm / 733 mm/ 569 mm (24.4 in / 28.8 in/ 22.4 in) 84 kg (185 lb) -25'C to +60°C (-1 J"F to+ I 40°F) <65 dB(A) 4.8W Tronsformerless / OptiCool IP65 4K4H 100% SUNCLIX / screw terminal • • • (2 ports) / • / O •!•!• • / • (2 ports) •!•!• •I• •fo/o/o ANRE 30. AS 4777. 8DEW 1008, CI0/1 I :1011, CE, CEI 016, CEI 021. EN 50438:2013•, G59/3, IEC 60068.2.,. IEC 61727, IEC 62109•1/2. IEC 62116. MEA20t6,NBR 16149,NENEN50438, NRS 097•2·1, PEA 2016, PPC. RD 1699/413. RO 661/2007, Re,. n•7:10l 3, S14777, TOR 04, TR 3.2.2, UTE c15.712.t, VOE 0126-1· t. VOE.ARN 4105, VFR 2014, PO 11.3, NTCQ.NTCyS,GC 8.9H, PR20. DEWA • Standard features O Optional -Not available Doto at nominal conditions• status: 07/2017 Type designanon STP 50-40 Assessories SMA Sensor Module MD.SEN•40 -+ SMA IQ.Module MD.10-40 SMA RS485 Module MD.485•40 Extension Kit EXTANT-40 CT]Antenno AC Surge Protection Module Kit AC SPD Kit\.\0 DC -Surg; Protection Module Kil DC_SPD_Kit4. \0 SMA Solar Technology ROOFM0UNT :E1UNI RAC ROOFMO UNT introduces the Power of Simplicity to the ballasted fiat roof solar industry. The system consists of only two major components, minimizing prepara tion work and installation time. Seamlessly design around roof obstacles. support most framed modules and bond the system with just the turn of a wrench. J ~ ff . !!!!!l!!!!!!!!!========~,,.1 /U l =~===