Loading...
HomeMy WebLinkAbout2871 Crest Dr; ; CBRA2018-0045; Permit(city of Carlsbad Residential Associated Permit Print Date: 12/26/2019 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 2871 Crest Dr BLDG-Associated Permit Resid 1562204500 $ 529,397.36 1 5.00 MILES BUENA VISTA Work Class: Lot#: Reference #: Single Family Detached 3 DEV14044 Construction Type VB Bathrooms: 4.50 Orig. Plan Check #: PC2016-0052 Plan Check#: Permit No: CBRA2018-0045 Status: Closed -Finaled Applied: 03/12/2018 Issued: 01/10/2019 Permit 09/03/2019 Finaled: Inspector: TFraz Final Inspection: 09/03/2019 Description: LANAI 11: PHASE 1 // LOT 3 // PLAN 2A // 3,272 SF LIV// 587 SF GARAGE// 323 SF PATIO// 169 SF DECK Applicant: SHEA HOMES LIMITED PARTNERSHIP SARAH MORRELL 858-526-6555 FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) Owner: SHEA HOMES LIMITED PARTNERSHIP 858-526-6554 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PARK IN-LIEU FEES SF DETACHED & DUPLEX: NW PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -outside CFD SB1473 GREEN BUILDING STATE STANDARDS FEE SDCWA SYSTEM CAPACITY CHARGE 5/8" Displacement SEWER CONNECTION FEE (General Capacity all areas) STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1-Medium BLDG SWPPP PLAN REVIEW FEE TIER 1 -MEDIUM TRAFFIC IMPACT Residential Single Fam. Outside CFD WATER METER FEE 1" Displacement (P) WATER SERVICE CONNECTION FEE 5/8" DISPLACEMENT (P) WATER TREATMENT CAPACITY CHARGE 5/8" Displacement Total Fees: $ 44,998.52 Total Payments To Date: $ 44,998.52 Building Division Balance Due: AMOUNT $2,127.00 $1,369.79 $96.00 $170.00 $110.00 $7,649.00 $224.00 $18,528.91 $22.00 $5,267.00 $960.00 $68.82 $246.00 $56.00 $3,390.00 $282.00 $4,286.00 $146.00 $0.00 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov . -·----·· .. ., ...... ____________ _ PERMIT INSPECTION HISTORY REPORT (CBRA2018-0045} Permit Type: BLDG-Associated Permit Residential Application Date; 03/12/2018 Owner: Work Class: Issue Date: Subdivision: Status: Single Family Detached Closed -Finaled Expiration Date: 01/10/2019 02/25/2020 10038 Address: IVR Number: Actual Scheduled Date Start Date Inspection Type Inspection No. 06/2112019 02101/2019 02/01/2019 02/07/2019 02/07/2019 0211412019 02114/2019 02/20/2019 02/20/2019 02/27/2019 02/27/2019 04/16/2019 04/16/2019 September 03, 2019 BLDG-17 Interior Lath/Drywall 092660-2019 Checklist Item BLDG-Building Deficiency BLOG-18 Exterior Lath/Drywall 092661-2019 Checklist Item BLDG-Building Deficiency BLDG-23 Gas/Test/Repairs 092662-2019 Checklist Item BLDG-Building Deficiency BLDG-21 Underground/Underf loor Plumbing 082861-2019 Checklist Item BLDG-Building Deficiency BLDG-21 Underground/Underf loor Plumbing 083224-2019 Checklist Item BLDG-Building Deficiency BLDG-11 Foundatlon/Ftg/Pler s (Rebar) 083880-2019 Checklist Item BLDG-Building Deficiency BLDG-11 Foundatlon/Ftg/Pler s (Rebar) 084090-2019 Checklist Item BLDG-Building Deficiency BLDG-22 SewerfWater Service 084908-2019 Checklist Item BLDG-Building Deficiency BLDG-16 Roof/ReRoof (Patio) 089093-2019 Inspection Status Primary Inspector Passed Paul York COMMENTS Passed Paul York COMMENTS Passed Paul York COMMENTS Cancelled Tim Frazee COMMENTS Too wet, forms full of water Passed Tim Frazee COMMENTS Too wet, forms full of water Cancelled Tim Frazee COMMENTS Cancelled due to Rain Passed Tim Frazee COMMENTS Cancelled due to Rain PaHed Tim Frazee COMMENTS Passed Tim Frazee SHEA HOMES LIMITED PARTNERSHIP 2871 Crest Dr Ca~sbad, CA 92008 Reinspectlon Passed No Passed No Passed No Reinspection Passed No Passed Yes Re inspection Passed No Passed Yes Passed Yes Complete Complete Complete Complete Complete Complete Complete Complete Complete Complete Page 1 of 3 PERMIT INSPECTION HISTORY REPORT (CBRA2018·0045) Permit Type: BLDG-Associated Pem1it Residential Application Date: 03/1212018 Owner: SHEA HOMES LIMITED PARTNERSHIP Work Class: Single Family Detached Issue Date: 01/1012019 Subdivision: Status: Closed -Finaled Expiration Date: 0212512020 Address: 2871 Crest Dr Carlsbad, CA 92008 IVR Number: 10038 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Re inspection Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 04/23/2019 0412312019 BLDG-13 Shear 089672-2019 Passed Tim Frazee Complete Panels/HD {ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Exterior shear OK to wrap 4/23/19 Yes 06/13/2019 06/13/2019 BLDG-84 Rough 091674-2019 Passed Andy Krogh Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 06/15/2019 06/16/2019 BLDG-16 Insulation 091933-2019 PaHed Andy Krogh Complete 06/21/2019 06/20/2019 BLDG-17 Interior 092293-2019 Failed Paul York Relnspection Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No 07108/2019 07108/2019 BLDG-32 Const. 096827-2019 Passed Michael Collins Complete Service/Agricultural( Temp) Checklist Item COMMENTS Passed BLDG-Building Deficiency EMR emailed to SDGE Yes 08/21/2019 08/21/2019 BLDG-Gas Meter 101487-2019 PaHed Michael Collins Complete Release Checklist Item COMMENTS Passed BLDG-Building Deficiency GMR emailed to SDGE Yes 08/29/2019 08/29/2019 BLDG-Flnal 102446-2019 Failed Paul York Reinspection Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-Plumbing Final No BLDG-Mechanical Final No BLDG-Structural Final No BLDG-Electrical Final No September 03, 2019 Page 2 of 3 PERMIT INSPECTION HISTORY REPORT (CBRA2018-0045} Permit Type: BLDG-Associated Permit Residential Application Date: 03/12/2018 Owner: Work Class: Single Family Detached Issue Date: 01/10/2019 Subdivision: Status: Closed -Finaled Expiration Date: 02/25/2020 Address: IVR Number: 10038 Actual Scheduled Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector 09/03/2019 09/03/2019 September 03, 2019 BLDG-Final Inspection 102764-2019 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final Passed Paul York COMMENTS SHEA HOMES LIMITED PARTNERSHIP 2871 Crest Dr Ca~sbad, CA 92008 Re Inspection Passed Yes Yes Yes Yes Yes Complete Complete Page3of3 ~~~~~,Q\ IMpQctlon and Testing Inc (56 ommerc,af Way, la Habra, Ca 9063; • 2) 941•2990 • (714) 526-8441 • Fax (562) 946-0026 REGISTERED INSPECTOR'S DAIL y REPORT I SWIT,Job No. I Da.te I I /; ,r l ( • i.. I TYPE OF · D Reinforced Concrete D Welding INSPECTION D Post Tensioned Concrete D Fireproofing □ DIA/Epoxy REQUIRED O Reinforced Masonry O Asphalt □ Wood Framing Job Addre~ J ,,.-) ,. l I J } ,, -· Tract No. i V1 • . 1 □ Other (. ~-/ v•~ ~ I Lot No. / ~ -. \.. ... I • ' -.. -. Job Namt:_~ , / ii , ~ ,J Permit N<?-. -,.,.,,,<..l,4 , ( I I • I ( I I ,., ./ / l~sued By i ,,. f .,, I/ ~ ... Type of Structure J ~ / /(. Architect ' ... __ I-:: -l-1 Material Description (type, grade, source) ,. Engineer ' ,·/ -.. . -·-.... (., I I I ..... Contractor I • \.. _.L, i ;; /( Inspector's Name / It ,,.,--Subcontractor -/• ~ : ' I TES-TS-PERFOR'MED I SAMPLE AIR CONC WATER TIME SET# TRUCK# TICKET# LOCATION SLUMP TEMP TEMP ADDED CAST MIX# REMARKS ., ,. ! / ,· . / ; INSPECTION SUMMARY-LOCATIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS, REMARKS, ETC. INCLUDES INFORMATION ABOUT -AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED, NUMBER, TYPE & IDENT. NO'S OF TEST SAMPLES TAKEN: STRUCT. CONNECTIONS (WELD MADE H.T. BOLTS TORQUED\ CHECKED, ETC. , -, , I .... --, I / '- r .. --' . '. L J / c... I ' ... <;...L ~-.,,; , / --. . { /, ) -:~ , I/ ' ( // . ,• , I , <" / 1 -/ 11 .. I~. • /) "' ..... : I../. ; , .,_:, ~ -~ / . '-· i /, ,!. 1,I . . ~ . CERTIFICATION OF COMPLIANCE HEREBY CERTIFY THAT I HAVE OBSERVED TO THE BEST OF MY KNOWLEOGE \LL OF THE ABOVE REPORTED WORK UNLESS OTHERWISE NOTEO. I HAVE =OUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATION, ~ND APPLICABLE SECTION OF THE GOVERNING BUILDING LAWS. ,, SIGNATURE 01;.AEGIST~RED INSPECTOR ( l '7'" (. ( ' _j I , ' .•_,,I ,., ' . l. -_, , "'?. > ,. ... . .. • ., . .. ; ,._f. '' ~ . • c.. ' ' , --, ' CONTINUED ON NEXT PAGE 0 PAGE TIMEIN TIMEOUT I -OF SAMPLES OGEOCON 0 Cl ---- FOUNDATION OBSERVATION REPORT PROJECT NAME: Lonai rr (-,v'l"'>-7 ;, ? PROJECT NO. ::, .,,,,.. ... 7:, 1 --' - LOCATION: P,,,, 1 lrl, 1"') Pod s I , 2, 3 > I AGENCY PROJECT NO: APPROVAL/ PERMIT NOS: DATE ~IICJ/)Cf P-.-:{ I-1qJ+1 P,111-nt-df ,r.Jq Cf:'42,l\;,),Q/~ ~"lf/ D ADDITIONAL OBSERVATION REQUIRE FOUNDATION TYPE: A:-irf ~ -lfsYl:i i:;1, ... hr.i j/,--k D 0 CONVENTIONAL ( p,~ A x-,c:.-00'-14 Ji?{ SUBSTANTIAL CONFORMANCE ftl POST-TENSIONED ~.d 3 """'21.B 71 r, . ., + Di·, v1e-· • PURPOSE OF OBSERVATION liq Check soil conditions exposed are similar to those expected Ill Check footing excavations extend to minimum depth recommended in soil report " ~ Check footings have been extended to an appropriate bearing strata D Other ____________________________________ _ • APPLICABLE SOIL REPORT: TITLE: F, fl.-:, I /\"",:,,per I "">' r r f-C' ~ .... , v,,-...., r I I •· • ., f , l e:J' L •'· I ~ I "Ji _______ ;_, __________________ DATE: P-· ~ I -j X' • SOIL REPORT RECOMMENDATIONS BASED ON: 1'J. Expansion Condition Q Very Low (0-20) D Low (2 1-50) D Medium (51-90) D High (91-130) D Very High (> 130) D Fill Geometry _________________________________ _ D Other: ____________________________________ _ • M IN IMUM FOUNDATION RECOMMENDATIONS: Footing Depth: ~ 12 Inches D 18 Inches □ 24 Inches OTHER: Footing Reinforcement: D No.4 T&B D 2-No.4 T&B D 2-No.5 T&B ~-Post-Tensioned OTHER: ______ _ Interior Slab Reinforcement: □ 6x6-l 0/10 D 6x6-6/6 D No.3@24 Inches D No.3@18 Inches ,Ii{ Post-Tensioned • FOUNDATION CATEGORY: DNA _______________ _ D II D Iil __________________ _ • OBSERVATIONS: fl· Substantial conformance with Soil Report. D Substantial conformance with Foundation Plans. ldenti.1----------------------- D Other • COMMENTS: S@,. .A/o ~ f'r"n,r1vocf Jor.,.:.,r I c. ·J / n,,.., /.-,-, ,., ( NOTE: FOOTING EXCAVAT!ONS SHOULD BE CLEANED OF LOOSE MATERIAL PRIOR TO PLACING CONCRETE AND THE SOIL MOISTURE CONTENT SHOULD BE MAINTAINED. .,J ',... 4' n I;:; >,. <2 z (-' fl I (" i.-v-r.; t , . FIELD COPIES TO , .. ' -~8 I, Id -f'Y I'../ . , ·• . ,b1q ,. (),} /,'f"J1C, , . n,,,,.,.:.-i ._,J-J,,,'(-_f; GEOCON REPRESENTATIVE !'I.ANNING ENGINEERING SURVEYING IRVINE SAN DIEGO RIVFRSIDE PALM DESERT HUNSAKER &ASSOCIATES SAN IJl[GO. INC. February 14, 2019 Los ANGEi ,s City of Carlsbad Engineering Department 1635 Faraday Avenue Carlsbad, CA 92008-7314 Re: Building Form Setback Certification Lanai II -Miles Buena Vista Carls bad Tract CT 14-04 Drawing No. 496-6A Lots 1 through 3 Dear City Inspector: Please be advised the building foundation forms are in conformance with the precise grading plans as to horizontal and vertical location. The building setbacks were measured in relation to the property lines and were found to be in conformance with the approved precise grading plans for this property. Sincerely, Hunsaker & Associates San Diego, Inc. cL , L_________, Gary C. Kraus P.L.S. 8770 DAVE HAMMAR ALISA VIAi.PANDO RAY MARTIN CHUCK CATER OOUGSTROLJP 0707 Waples Street San Diego, Cl\ 92111 (115ft) 5.'i6-4.5ll0 PH (85K) 551\-141-1 F X w1.vw.l lunsakerSD.com l11(o@Hu11s,1kerSD.mm Principal, Director of Survey 8H:ko k:lll081\2019\u1?6.d~ci wa 61-~94 2/U/201910:37 AM '<~' ~ CITY 0~ CARLSBAD Building Division RECORD COPY INSPECTION RECORD li'I INSPECTION RECORD CARD WITH APPROVED .-.._"NS MUST BE KEPT ON THE JOB CBRA2018-0045 2871 CREST DR lo+3 LANAI II: PHASE 1 // LOT 31/ PLAN 2A 1/ 3,272 SF LIV 1/ 587 SF GARAGE I/ 323 SF PATIO// 169 SF DECK li:J·-.ALL BEFORE 3:00 pm FOR NEXT WORK DAY INSPECTION li'I FOR BUILDING INSPECTION CALL: 760-602•2725 DEV14044 1562204500 PC2016-0052 3/1212018 OR GO TO: www.Carlsbadca gov/Building AND CLICK ON "Request Inspection" DATE: I -Io-(0\ CBRA2018-0045 If "YES"' is checked below that Division's approval is required pr_ior_to r!;!!)uesti,~ a Final Building Inspection. If you have any questions please call the applicable divisions at the phone numbers provided below. After an required approvals are signed off-fax to 760-602-8560, email to fl_ljf_ginsp~,;;tiP!!_S@ca:rlsb~ct~£ov or bring in a COPY of this card to: 1635 Faraday Ave., Carlsbad. YES NO IF MARKED "YES", IT IS REQUIRED PRIOR TO ANY CONSTRUCTION Date Inspector Notes STORM WATER PRECON MEETING REQUIRED 760-602-2725 Allow 24 hours IF MARKED 'YES", APPROVAL REQUIRED PRIOR TO REQUESTING BUILDING FINAL COPY OF CARO REOUlllE0 Fire Prevention Planning/Landscape CM&I /Engineering Inspections) #12 #66 MASONRY PRE GROUT ,-..,,, □ GROUT □ WALL ORAINS ".. TILT PANELS #11 POUR STRIPS #11 COLUMN FOOTINGS #14 SUBFRAME □ FLOOR □ CEILING #15 ROOF SHEATHING #13 EXT. SHEAR PANELS #16 INSULATION #18 EXTERIOR LATH #17 INTERIOR LATH & DRYWALL #24 TOP OUT □ WASTE □ WTR #27 TUB & SHOWER PAN #23~TEST □ GAS PIPING #25 WATER HEATER #28 SOLAR WATER BLDG-FINAL CODE# POOLS #51 POOL EXCAV / STEEL #52 PLUMBING #53 ELEC /CONDUIT/WIRING ,---._ EQUIPOTENTIAL BOND ._. PRE PLASTER/ FENCE/ ALARMS #57 GUNITE BLDG-FINAL REV 9117 760-602-4660 760-944-8463 760-438-389 I Date Ins ector Allow 46 hours Allow 46 hours #35 PHOTO VOLTAIC #38 SIGNS BLDG-FINAL #82 DRVWALL,EXTLATH, GAS TES (17,18,23) #83 ROOF SH EATING, EXT SHEAR (13,15) Date Inspector Date ln.s ector Date Ins ector #84 FRAME ROUGH COMBO (14,24,34,44) 'j #85 T-Bar (14,24,34,44) BLOG-ANAL OCCUPANCY A/S UNOERGROUNO VISUAL A/S UNDERGROUND HYDRO A/S UNDERGROUND FLUSH A/S OVERHEAD VISUAL A/5 OVERHEAD HYDROSTATIC A/SRNAL F/A ROUGH-IN F/AFINAL RXED EXTINGUISHING SYSTEM ROUGH-IN RXED EXTING SYSTEM HYDROSTATIC TEST FIXED EXTINGUISHING SYSTEM ANAL MEDICAL GAS PRESSURETEST MEDICAL GAS RNAL Date Ins ector SEE BACK FOR SPECIAL NOTES