HomeMy WebLinkAbout2872 Trails Ln; ; CB153205; PermitPrint Date: 01/15/2020
Job Address:
PermitType:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
2872 Trails Ln
BLDG-Residential
1560904100
$439,241.00
1
3.00
TRAILS END
Residential Permit
Work Class:
Lot#:
Reference #:
Construction Type:
Bathrooms:
Orig. Plan Check#:
Plan Check#:
Single Family Attached
DEV04063
VB
4.50
PC130072
{"city of
Carlsbad
Status:
Applied:
Issued:
Permit
Fina led:
Inspector:
Final
Inspection:
Permit No: CB153205
Closed -Finaled
09/29/2015
12/19/2017
PBurn
1/15/2020 3:13:51PM
Description: TRAILS END-TYPE 1-UNIT 10-SF ATTACHED 2781 SF, 523 SF GAR, 445 SF DECK
Applicant: Owner:
4 DESIGN ARCHITECTURE
KENNITH L CHRISS
TRUST THE PEV FAMILY REVOCABLE TRUST
5505 Can cha De Golf
Rancho Santa Fe, CA 92091-4041
760-433-1785
BUILDING PERMIT FEE $2000+
BUILDING PLAN CHECK FEE (BLDG)
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PUBLIC FACILITIES FEES -outside CFD
SB1473 GREEN BUILDING STATE STANDARDS FEE
SDCWA SYSTEM CAPACITY CHARGE 5/8" Displacement
SEWER CONNECTION FEE (General Capacity all areas)
STRONG MOTION-RESIDENTIAL
TRAFFIC IMPACT Residential Condo Outisde CFD
WATER METER FEE 1" Displacement
WATER SERVICE CONNECTION FEE 5/8" DISPLACEMENT (P)
WATER TREATMENT CAPACITY CHARGE 5/8" Displacement
Total Fees: $31,814.64 Total Payments To Date: $31,814.64 Balance Due: $0.00
$1,833.00
$783.10
$66.00
$166.00
$92.00
$182.00
$15,373.44
$18.00
$5,029.00
$934.00
$57.10
$2,632.00
$352.00
$4,169.00
$128.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as 11fees/exaction,11 You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
PERMIT INSPECTION HISTORY REPORT (CB153205)
Permit Type: BLDG-Residential Application Date: 09/29/2015 Owner:
Work Class: Single Family Attached Issue Date: 12/19/2017 Subdivision:
Status: Closed -Finaled Expiration Date: 04/28/2020 Address:
IVR Number: 709463
Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector
01/15/2020 01/15/2020 BLDG-Final
Inspection
January 15, 2020
Checklist Item
BLDG-Building Deficiency
116376-2020
Checklist Item
BLDG-Building Deficiency
BLOG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
COMMENTS
Passed Paul Burnette
COMMENTS
TRUST THE PEV FAMILY
REVOCABLE TRUST
2872 Trails Ln
Carlsbad, CA
Reinspection Complete
Passed
Yes
Passed
Yes
Yes
Yes
Yes
Yes
Complete
Page 4 of 4
PERMIT INSPECTION HISTORY REPORT (CB153205)
Permit Type: BLDG-Residential Application Date: 09/29/2015 Owner: TRUST THE PEV FAMILY
REVOCABLE TRUST
Work Class: Single Family Attached Issue Date: 12/19/2017 Subdivision:
Status: Closed -Finaled Expiration Date: 04/28/2020 Address: 2872 Trails Ln
Carlsbad, CA
IVR Number: 709463
Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete
Date Start Date
05/29/2019 05/29/2019 BLDG-17 Interior 093025-2019 Partial Pass Paul Burnette Relnspectlon Incomplete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
06/17/2019 06/17/2019 BLDG-84 Rough 094780-2019 Passed Chris Renfro Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
06/19/2019 06/19/2019 BLDG-13 Shear 095052-2019 Partial Pass Chris Renfro Reinspection Incomplete
Panels/HD (ok to
wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Int. Shear Yes
06/21/2019 06/21/2019 BLOG-16 lnsulatlon 095308-2019 Passed Mlchael Collins Coriiplete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
07/01/2019 07/01/2019 BLDG-82 Drywall, 096152-2019 Passed Chris Renfro Complete
Exterior Lath, Gas
Test, Hot Mop
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-17 Interior Lath-Drywall Yes
BLDG-18 Exterior Lath and Yes
Drywall
BLDG-23 Gas-Test-Repairs Yes
08/14/2019 08/14/2019 BLDG-21 100750-2019 Passed Chris Renfro Complete
Underground/Underf
loor Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Denciency Backflow underground PVC to main line Yes
connection. OK to backfill
10/31/2019 10/31/2019 BLDG-33 Service 109354-2019 Passed Chris Renfro Complete
Change/Upgrade
January 15, 2020 Page 3 of 4
PERMIT INSPECTION HISTORY REPORT (CB153205)
Permit Type: BLDG-Residential Application Date: 09/29/2015 Owner:
Work Class: Single Family Attached Issue Date: 12/19/2017 Subdivision:
Status: Closed -Finaled Expiration Date: 04/28/2020 Address:
IVR Number: 709463
Scheduled
Dale
Actual Start Date Inspection Type Inspection No.
Checklist Item
BLDG-Building Deficiency
03/15/2019 03/15/2019 BLDG-14 086234-2019
Frame/Steel/Bolting/
Welding (Decks)
Checklist Item
BLDG-Building Deficiency
04117/2019 04117/2019 BLDG-15 089333-2019
Roof/ReRoof (Patio)
Checklist Item
BLDG-Building Deficiency
04118/2019 04118/2019 BLDG-13 Shear
Panels/HD (ok to
wrap)
089349-2019
Checklist Item
BLDG-Building Deficiency
BLDG-14 089150-2019
Frame/Steel/Bolting/
Welding (Decks)
Checklist Item
BLDG-Building Deficiency
05/1412019 05/1412019 BLDG-14 091808-2019
Frame/Steel/Bolting/
Welding (Decks)
Checklist Item
BLDG-Building Deficiency
05/2312019 05/23/2019 BLDG-16 lnsulallon 092634-2019
Checklist Item
BLDG-Building Deficiency
05/24/2019 05/2412019 BLDG-13 Shear
Panels/HD (ok to
wrap)
092841-2019
Checklist Item
BLDG-Building Deficiency
January 15, 2020
Inspection Status Primary Inspector
COMMENTS
Floor sheathing on basement floor
Partlal Pass Tim Frazee
COMMENTS
Floor sheathing on basement floor
Floor sheathing on 3rd floor, upper floor
3/15/19
Passed Tim Frazee
COMMENTS
Roof sheeting nailing OK
Passed Tim Frazee
COMMENTS
Passed Tim Frazee
COMMENTS
Floor sheathing on basement floor
Floor sheathing on 3rd floor, upper floor
3/15/19
Roof sheathing OK 4/18/19
Partial Pass Paul Burnette
COMMENTS
Partial Pass Paul Burnette
COMMENTS
Partial Pass Andy Krogh
COMMENTS
Prelim shear at party. walls
TRUST THE PEV FAMILY
REVOCABLE TRUST
2872 Trails Ln
Carlsbad, CA
Re inspection
Passed
Yes
Relnspectlon
Passed
Yes
Passed
Yes
Passed
Yes
Passed
Yes
Reinspectlon
Passed
No
Relnspectlon
Passed
No
Reinspection
Passed
Yes
Complete
Incomplete
Complete
Complete
Complete
Incomplete
Incomplete
Incomplete
Page2of4
PERMIT INSPECTION HISTORY REPORT (CB153205)
Permit Type: BLDG-Residential Application Date: 09/29/2015 Owner: TRUST THE PEV FAMILY
REVOCABLE TRUST
Work Class: Single Family Attached Issue Date: 12/19/2017 Subdivision:
Status: Closed -Finaled Expiration Date·: 04/28/2020 Address: 2872 Trails Ln
IVR Number: 709463 Carlsbad, CA
Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspectlon Complete Date Start Date
12/20/2017 BLDG-21 044272-2017 Passed Paul Burnette Complete
Underground/Underf
loor Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
01/23/2018 01/2312018 BLDG-11 046591-2018 Partial Pass Paul Burnette Relnspectlon Incomplete
Foundatlon/Ftg/Pler
s (Rebar)
Checklist Item COMMENTS Passed
BLDG-Build!ng Deficiency No
02/14/2018 05/01/2019 BLDG-66 Grout 048773-2018 Cancelled Paul Burnette Relnspectlon Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
03/09/2018 03109/2018 BLDG-11 051137-2018 Passed Paul Burnette Complete
Foundatlon/Ftg/Pler
s (Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
03/27/2018 03/27/2018 BLDG-66 Grout 052862-2018 Partial Pass Paul Burnette Relnspectlon Incomplete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
04/10/2018 04/10/2018 BLDG-66 Grout 054430-2018 Passed Paul Burnette Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
06/05/2018 06/05/2018 BLDG-11 059957-2018 Passed Paul Burnette Complete
Foundatlon/Ftg/Pler
s (Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
10/23/2018 10/23/2018 BLDG-11 073885-2018 Partial Pass Tim Frazee Relnspectlon Incomplete
Foundatlon/Ftg/Pler
s (Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Footings Check No
01/25/2019 01/25/2019 BLDG-14 082187-2019 Partial Pass Tim Frazee Relnspectlon Incomplete
Frame/Steel/Bolting/
Welding (Decks)
January 15, 2020 Page 1 of4
<._~)
~ C!T'I' 0~,
CARLSBAD
REC,ORD COPY
INSPECTION RECORD
CB153205
2872 TRAILS LN Building Division
611 INSPECTION RECORD CARD WITH APPROVED
TRAILS END-TYPE 1-UNIT 10-SF ATTACHED 2781 SF
523 SF GAR 445 SF DECK
PLANS MUST BE KEPT ON THE JOB
611 CALL BEFORE 3:00 pm FOR NEXT WORK DAY INSPECTION
0 FOR BUILDING INSPECTION CALL: 760-602-2725
OR GO TO: www.Carjsbadca.gov/BuHdinq AND CLICK ON
"Request Inspection"
DATE: \
DEV04063
PC130072
1560904100
12/14/2017
CB153205
If "YES·' is ched.(:d he low that Divi~,ion·s .1pproval is required i:,;;or to requestin1,{ a Fi11;1I Building 111~,pection. If you have any questions
please call the ;ipphcahl<! div1sioni> at the 1ihone numiiers provided he!ow. After .-ill required approvals are signed ott f.ix to
7{i0-G02"8!3h0. email to hltlginsJH:ctions(;,,carlslJadc;q.;ov 01 bring i11 il COPY of this card to: 1()35 F;1tacl.1y Ave. C;nt~!i.1d.
Required Prior to Requesting Building Final If Checked YES
Plan11ing/Landscape 760-944-8463 Allow 48 hours
CM&l /Engineering Inspections) 760-438-3891 Call before 2 pm
Fire PreventJon 760-602-4660 AJlow 48 hours
Date Inspector
#12 REINFORCED STEEL
#88 MASONRY PRE GROUT
ROUT □ WALL DRAINS
#10 TILT PANELS
#11 POUR STRIPS
#11 COLUMN FOOTINGS
#14 SUBFRAME □ FLOOR □ CEILING
#16 ROOF SHEATHING
#13 EXT. SHEAR PANELS
#18 INSULATION
#18 EXTERIOR LATH
#17 NTERIOR LATH & DRYWALL
#51 POOL EXCA/STEEL/BONO/FENCE #82 DRYWALL,EXT LATH, GAS TES (17,18,23)
#55 PREPIASTER/FINAL #83 ROOFSHEATING, EXT SHEAR (13,15)
#19 FINAL #84 FRAME ROUGH COMBO (14,24,34,44)
CODJ, II PLUMBING Date Ins r #86 T-8ar(14,24,34,44)
#22 □ SEWER & BL/CO □ PL/CO #89 FINAL OCCUPANCY (19,29,39,49)
#21 UNDERGROUND □WASTE □ WIR Date Ins
#24 TOP OUT □ WASTE □ WIR A/5 UNDERGROUND VISUAL
#27 TUB & SHOWER PAN A/S UNDERGROUND HYDRO
#23 □GAS TEST □GAS PIPING A/S UNDERGROUND FLUSH
#25 WATER HEATER A/S OVERHEAD VISUAL
#28 SOLAR WATER A S OVERHEAD HYDROSTATIC
#29 FINAL A/S FINAL
com rt STORM WATER F/AROUGH-IN
#600 PRE-CONSTRUCTION MEETING F/AFINAL
#603 FOLLOW UP INSPECTION FIXED EXl'INGUISHING SYSTEM ROUGH-IN
#606 NOTICE TO CLEAN FIXED EXTING SYSTEM HYDROSTATIC TEST
#607 WRITTEN WARNING FIXED EXTINGUISHING SYST£M FINAL
#609 NOTICEOFVIOLATION MEDICAL GAS PRESSURE TEST
#810 VERBAL WARNING MEDICAL GAS FINAL
REV 10/2016 SEE BACK FOR SPECIAL NOTES
~ GEOCENTRIC
I. A:--,· D SL.RV E \' l NG \ '.\' D :\1 .\PP I'.'\ C
April 5, 2019
To Whom It May Concern:
Subject: Trails End, Donna Drive, Carlsbad
Geocentric Land Surveying performed an as-built field survey on April 4, 2019 and I hereby
certify that the framing on the roof, is as s.hown on the the following table.
LOT GARAGE
PAD
1 253.97
2 251.97
7 216.97
8 214.97
9 215.47
10 217.47
11 217.47
12 219.47
13 228.97
14 230.97
Sincerely,
Lorne DaPron
PLS 7824
2ND RIDGE RIDGE LINE
FINISH LINE HEIGHT
FLOOR ABOVE PAD
254.64 276.02 22.05
252.64 274.03 22.06
217.64 239.14 22.17
215.64 237.13 22.16
216.14 237.59 22.12
218.14 239.63 22.16
218.14 239.66 22.19
220.14 241.64 22.17
229.64 251.08 22.11
231.64 253.09 22.12
2150 N C.:ntrc Ciry Pkwy Suire B, rscondi<lo CA 92U26
tel: 760.207.78'24 fax: 760.745.782.4
\ V\\'W.gL'lKCntricsurvcy .com
Construction Testing & Engineering, Inc.
Inspection I Testing I Geotechnica/ I Environmental & Construction Engineering I Civil Engineering I Surveying
DAILY FIELD REPORT
Client: Pacifica Real Estate Services Inc Job 10-13959T Number:
Job Name: Trails End Residential Subdivision Development Day(s): Monday
Job Location: 3151, 3155 Donna Dr. Carlsbad Ca. Date(s): 4-9-19 2876, 2880, 2884, 2888 Trails End Carlsbad Ca.
Engineer: HTK Structural Engineers LLP
Permit number: CB153136, CB153197, CB153201, CB153200, CB153199, CB153198
Shear-wall Special Inspection
Performed the shear-wall special inspections on the shear-walls
that had fastener spacing at 4" or less per CBC section 1705 at
lot #1, #2, #11, #12, #13 and lot #14 per sheet S4. 0 Basement,
lower floor and main floor, sheet S4.1 upper floor and roof plan.
Verified correct materials, nailing spacing, hold-downs, foundation
connection and shear transfer between floors/roof. All corrections
were performed during the inspections, the installation is in
compliance with the approved plans.
Certification of Compliance: All work, unless otherwise noted, complies with the BP.
the California Code of Re ulations Title 24.
NAME: Bill Atwood SIGNATURE:
CERTIFICATION NO: 5012754
1441 Montiel Road, Suite 115 I Escondido, CA92026 I Ph (760) 746-4955 I Fax (760) 746-9806 I www.cte-inc.net
W.O. 6/ _;--·-_ L
DATE /L-L -?-; 7
NAME /.2. C/t.l smA ~,
HOURS ______ _
.G._eotechnical • Coastal • Geologic • Environmental
FOOTING TRENCH OBSERVATION SUMMARY
Client Name: V_;; f1 rJ A Vil /,JC, , L l c.,_ Project Name: --r;;_/J' l /~ b '?.> -----'~~~--~-~-------, ....... ...;...a;'--'------------
---I ,,-, ,,,~ } I , -. ., Location/Tract: __,l~fZ,:.::•-'' l,:_i'--'.$"--~/-=---=•?c...:)::....,,,.., __;:L;.:;_'_:,,(_,il .;....'....:!b..::.~~A;_;_J.,~ _ _;L=-...... 7_-__ v___,~c....l _-_/;_·_Y ____________ _ ,,
Unit/Phase/Lot(s): _/4_.._-r....;;J'---_,_7 ..... /'--'-'-i ...... _...;.7~/.!.:/o:....,.:...· -".;...,'/;:../,'-; z.:;;.....,.:...' _,_?'-/~/_'/ _____________ _ • t
Referenced Geotechnical Report(s): _O---"/;'""".,_tt __ ~~'-, ___ !0=-.,.._-1.....;-._=':,_; ___ j_-_!_7_-,,--_b_. _-____ b_;· _~ l_b _________ _ ,,,.
Observation Summary
_1.,/ 1 · I ,, rntia s A representative of GeoSoils, Inc. observed onsite soil and footing trench conditions. Soil conditions
in the trench are generally free of loose soil and debris, non-yielding and uniform, and plumb; and
are in general conformance with those indicated in the geotechnical report.
IL/t1 Date .
/ .. /
1l-/l 1
--,:_/<
u~ ,
i-
tV/2 i
Initials
Date
Initials
Date
Initials
Date
A representative of GeoSoils, Inc. observed and reviewed footing excavation depth/width. Footing
excavations generally extend to proper depth and bearing strata, and are in general conformance
with recommendations of !he geotechnical report.
A representative of GeoSoils, Inc. reviewed footing setbacks from slope face (if applicable). The
setback was in general accordance with the recommendations of the geotechnical report.
I
Notes to Superintendent/Foreman
1,) Footing excavations should be cleaned of loose debris and thoroughly moistened just prior to placing concrete. --·2. Based on expansion potential of underlying soils, presoaking of soil below slabs may be recommended. Consult
the geotechnical report for presoaking recommendations. We note that clayey soils may tak~~xtended
period of time for such, and the contractor should schedule according[Y?"_..e::"' €£? /'-;7u/ s I'~
3. In the event of a site change subsequent to our footing observation and prior to concrete placement (i.e., heavy
rain, etc.), we should be contacted to perform additional site observations and/or testing.
4. This memo does not confirm the minimum footing dimension as required by the project structural engineer's
design, if different from the geotechnical report.
Notes to Building Inspector
Soil compaction test results, as well as depth of fill, relative compaction, bearing values, corrosivity, and soil expansion
index test results are contained in the As-Graded Geotechnical or Finai·Compaction Report provided at the completion
,o!grading. // /7
~~L -._ ___ __
5741 Palmer Way
Carlsbad, CA 92008
(760) 438-31 55
1446 E. Chestnut Ave.
Santa Ana, CA 92701
(714) 647-0277
Representative of GeoSoils, Inc.
26590 Madison Ave.
Murrieta, CA 92562
(951) 677-9651
w.o. 0 t6 3 5 -c.
DATE_l_-_1-_-_I t:,~-
NAME Mt V-..E' ~~\--
HOURS_~1-'---. o~---
Geotechnical • Coastal • Geologic • Environmental
FOOTING TRENCH OBSERVATION SUMMARY
Client Name: Do,....__, NA D12.,\/E: ( t---L C Project Name: in. V\-1 L. S 13:.· Nb
Location/Tract: Tn..v-"t, t..5 END CA1<.Lsl3AD c., ot-t -IL.f
Unit/Phase/Lot(s): __ l-_o __ r_.s ______ l ...... /_--z... ____ 3a...,_/ Lf_,_-...... _ ..... .5...___/_e:,=-;-_____ (_1 _-_G._) _______ _ , /
Referenced Geotechnical Report(s): --'D~A_,__·,'--',... E:~D _ __,_I =o_-___ 3"'"'1'------'-l_7_,__,/ ______ b;;;;;;..__-~b=-----'-/--6'--______ _
Observation Summary
V\.-i5 Initials
l /-z./ 19, Date
)A 5 Initials
1 li/1 B Date
tV, S Initials
t /-2./ 18 Date
v-L-1• 5 Initials
11 z.. I tR Date
A representative of GeoSoils, Inc. observed onsite soil and footing trench conditions. Soil conditions
in the trench are generally free of loose soil and debris, non-yielding and uniform, and plumb; and
are in general conformance with those indicated in the geotechnical report.
A representative of GeoSoils, Inc. observed and reviewed footing excavation depth/width. Footing
excavations generally extend to proper depth and bearing strata, and are in general conformance
with recommendations of the geotechnical report.
A representative of GeoSoils, Inc. reviewed footing setbacks from slope face (if applicable). The
setback was in general accordance with the recommendations of the geotechnical report.
PE.Rf-"on/J\J'oE-b 5erL.G-c,r //.J F'ric,RIN(., ON UN{)E:l'!.'5UA~ L,JrcU,'/ Tn:6'NC.li~:r , '""-<-Tic's
PAo(\1.....-<, I.Nh\C.v.tcJ T t-ftA:r 1irl..el'-l<'..l-\€S B'>Ac.kr-,1...1.. 15 R.&l<:-r.v,r'i C.oV'-"l,0., .. 1...r j
A~O SutrA,:,,LE" Fon.. ·rt-ti:: _.X:-..,._,T1::v->Ot',D u . .5C
Notes to Superintendent/Foreman
Q Footing excavations should be cleaned of loose debris and thoroughly moistened just prior to placing concrete.
2. Based on expansion potential of underlying soils, presoaking of soil below slabs maybe recommended. Consult
the geotechnical report for presoaking recommendations. We note that clayey soils may take an extended
period of time for such, and the contractor should schedule accordingly. ~ /<6e p Mo I s r ;¥;--
3. In the event of a site change subsequent to our footing observation and prior to concrete placement (i.e., heavy
rain, etc.), we should be contacted to perform additional site observations and/or testing.
4. This memo does not confirm the minimum footing dimension as required by the project structural engineer's
design, if different from the geotechnical report.
Notes to Building Inspector
Soil compaction test results, as well as depth offill, relative compaction, bearing values, corrosivity, and soil expansion
index test results are contained in the As-Graded Geotechnical or Final Compaction Report provided at the completion
of grading.
5741 PalmerWay
Car1sbad, CA 92008
1446 E. Chestnut Ave.
Santa Ana, CA 92701
Representative of G€o'soils, Inc.
26590 Madison Ave.
Murrieta, CA 92562
\
GEOCENTRIC
l. A~ l) S l. RV !·: \' l N l~ AN I) MAP I' I;-; C
January 3, 2018
To Whom It May Concern:
Subject: Trails End, Donna Drive, Carlsbad
Geocentric Land Surveying performed an as-built field survey on January 3, 2018 and found the
lower level building forms for buildings numbers 1 through 14 to substantially conform to the line
and grade as shown on the approved Precise Grading Plan. As such conforms to all building
setbacks.
Sincerely,
J /). ;< u/~.,,v.---
Lorne DaPron
PLS 7824 No. 7824
21SO 'Cc:nLn: C 1ty f'!.:wy Sui Le: n, LsconJid,1 , . .'\ 92()26
Le!: °?'0l1 .~\)(,T8~4 t.°i!X 76()],f) 7824
\VV,,.V/ ,SCOttt1 Lrj<.:~UfVty.con1
Construction Testing & Engineering, Inc.
Inspection I Testing I Geotechnical I Environmental & Construction Engineering I Civil Engineering I Suiveying
INSPECTION REPORT PAGE _j_ OF -/--
CTE JOB NO. /_I'? -/:S r S7
REPORT NO.
PROJECT NAME 7/:4 ,ls ,£ ,v-f ,1:/t?,tr.f; · INSPECTION MATERIAL IDENTIFICATION
ADDRESS ~'•11.A i:i.-t r!t,.ef.skt-J / /4 /h:pR 1.v. 0 CONCRETE CONC. MIX NO. & lb/in2
Ci;/T)s .ittc/ ~ REINF. STEEL GROUT MIX NO. & lb/in2
ARCHITECT f /Je.s.1 §1 ,, □ MASONRY MORTAR TYPE & lb/in2
ENGINEER !± T K_ □ P.T. CONCRETE REINF. STEEL GR./SIZE /1612 C /' 6<? 4--/ Ii .... ,,,.. r , /
CONTRACTOR Wi d~-& &ttl /l..cp,.k :;2er!': 1rre_r □ FIELD WELDING STRUCTURAL STEEL
OTHER 0 /'V} -r. □ SHOP WELDING HIGH-STRENGTH BOLT -----
INSPECTION DATE
PLAN FILE/OTHER
BLDG. PERMIT/OTHER
{~ -~-/-20 1 f MASONRY BLOCK
OTHER
0 BATCH PLANT
0 EXP. ANCHOR
0 OTHER ----------------
MATERIAL SAMPLING
0 CONCRETE O MORTAR O GROUT 0 FIREPROOFING O MASONRY BLOCK
0 BOLTS O OTHER 0 REINFORCING STEEL O STRUCTURAL STEEL
INSPECTIONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS
PLEASE NOTE ANY RE-INSPECTION, TESTING, OR OTHER PROJECT ISSUES. .;..• . -~
Certification of Compliance: All work, unless otherwise noted, complies with applicable codes and the approved plans and specifications.
PRINTED NAME
CERTIFICATION NO.
b1t 4,,,,,_'/ ,4-z/4,;
1441 Montiel Road, Suite 115 I Escondido, CA 92026 I Ph (760) 746-4955 I Fax (760) 746-9806·. I www.cte-inc.net
• W.O. /0 /e <, ;---C -' (.
DATE __ l-~~/ .... 1 __ / ___ ik_'. __
NAME __ L-...._""",-✓, __ ~ .... rrs ......... _::::r_._
HOURS ___ -: __ _
Geotechnical • Coastal • Geologic • Environmental
FOOTING TRENCH OBSERVATION SUMMARY
Client Name: b, ,1, ·1 A 'D~·z . LL c_ Project Name: --r.-4':], I ;, :f, 1;)
Location/Tract: 1>" .1 ,\J 1\,s, ,/,··",.,/, }:./,A,) 7i·~,tc.-;-c,· ,-y -1 Y
UniVPhase/Lot(s): __ f .... -c ___ -___ ~_::i_ .... 7-+/-..C_· ~-(_,.f...,/f--'-i , ..... _. _______________________ _
Referenced Geotechnical Report(s): ___ \c_) __ )_1 .... i __ \ .... __ i _~ _< __ .c_l ___ c __ ,., .... ! ... H ... e· ________________ _
Observation Summary
w)-::rr: Initials
• 1 \\h ~ Date
L) -:n.-Initials
✓~ \ 1 l\.'-< Date
'-~:~ Initials
• \-\ \'r-Date
,..-~ (-Initials
\, \ \l: Date
A representative of·GeoSoils, Inc. observed onsite soil and footing trench conditions. Soil conditions
in the trench are generally free of loose soil and d~bris, non-yielding and uniform, and plumb; and
are in general conformance with those indicated in the geotechnical report.
A representative of GeoSoils, Inc. observed and reviewed footing excavation depth/width. Footing
excavations generally extend to proper depth and bearing strata, and are in general conformance
with recommendations of !he geotechnical report.
A representative of GeoSoils, Inc. reviewed footing setbacks from slope face (if applicable). The
setback was in general accordance with the recommendations of the geotechnical report .
I f .:.._ ,y-i I
Notes to Superintendent/Foreman
1. Footing excavations should be cleaned of loose debris and thoroughly moistened just prior to placing concrete.
2. Based on expansion potential of underlying soils, presoaking of soil below slabs may be recommended. Consult
the geotechnical report for presoaking recommendations. We note that clayey soils may take an extended
period of time for Sl)Ch, and the contractor should schedule accordingly.
3. In the event of a site change subsequent to our footing observation and prior to concrete placement (i.e., heavy
rain, etc.), we should be contacted to perform additional site observations and/or testing·.
4. This memo does not confirm the minimum footing dimension as required by the project structural engineer's
design, if different from the geotechnical report.
Notes fo Bulldlng Inspector
Soil compaction test results, as well as depth offill, relative compaction, bearing values, corrosivity, and soil expansion
index test results are contained in the As-Graded Geotechnical or Final Compaction Report provided at the completion
of grading. 1 , ,' 1 -'"?
, . ,;,--f,--1-
5741 Palmer Way
Carlsbad, CA 92008
(760) 438-3155
, : (' I I ' l !
1446 E. Chestnut Ave.
Santa Ana, CA 92701
(714) 647-0277
Representatfve ofGeoSoils, Inc.
26590 Madison Ave.
Murrieta, CA 92562
(951 ) 677-9651
GEOCENTRIC
I \ '\ I l S l R \ I \ I '\ C. \ '\ ll \I \ I' I' I '\ C,
June 4, 2018
To Whom It May Concern:
Subject: Trails End, Donna Drive, Carlsbad
Geocentric Land Surveying performed an as-built field survey on June 4, 2018 and found the
garage/second floor forms for buildings numbered 7 through 10 to substantially conform to the
line and grade as shown on the approved Precise Grading Plan. As such conforms to all
building setbacks.
Sincerely,
Lorne DaPron
PLS 7824
]15l) "\ Ccntrl' Cit) l'k\\'j Suite n. T '-Cllnd1do C \ 92l\~6
tel 760.2t17 782-1 fax· 76l1.745.7824
\\'\\'\\ .gcnccntric~u" cy.c,1111