HomeMy WebLinkAbout2875 LOKER AV EAST; ; CB901918; Permit« •' BUILDING PERMIT
01/02/91 11:41
Page lofl
Job Address: 2875 LOKER AV EAST ' ' Str:
Permit Type: INDUSTRIAL TENANT IMPROVEMENT
Parcel No: 209-083-05-00 . ; •
Valuation: 129,487 ; ' , \ ' '
Construction Type: VN ' •
Occupancy Gi-oup: B2 Class Code:
Description: MOVE ELEC/ADDING WALLS
Permit No: CB901ylb
Project No: A9002196
Development No:
Fl: Ste:
m%. 01/02/91 0001.01 02 •
:,- . , '^•Wm 5538.00
Appl/Ownr : TECHBILT CONSTRUCTION CORP
3 57 5 KENYON STREET
SAN DIEGO, CA 92110
A*A Fees Required AXK
• • - / . Status: ISSUED
'f • Applied: 12/07/90
/ Apr/Issue: 01/02/91
Validated By: DC
619 223-1163
CoiiectecJ & Credits ***
Fees: 5,872.00
Adjustments: .00
Total Fees: 5,87;;.0t.'
Fee description * f t H
-ai Cr-fdits:
Totdi Pavinerits:
Balance Due:
Unii Fr^e/Unit
Building Permit
Plan Check
Strong Motion Fee
Enter 'Y' to Autocalc LiC'-!ise Tax >
* BUILDING TOTAL
Enter "Y" for Plumbin,<; :~ .-iis Fee
Each Plumbing Fixture • >r /raj^ .>
Gas Piping System
A PLUMBING TOTAL
Enter "Y" for Electric Issue Fee >
Three Phase Per AMP
* ELECTRICAL TOTAL ($10 Minimum)
Enter 'Y' for Mechanical Issue Fee>
Install Furn/Ducts ">
* MECHANICAL TOTAL . ,
jfHi^...
f -M
1 .00
» • » # 1 . U 0
OSi
1.00
2.50
2 . ':• 1.)
. 50
9.00
' : .00
3 3 4.00
5,538.00
Ext fee Data
74 5 0 0
484 00 '
19 0 0
4 5 32 00 Y
5780 0 0
7 50 Y
2 50
2 50
' 13 00
5 0 0 Y
50 00
55 0 0
15 00 Y
9 00
24 . 00
INSP. JL4I44-I)I(W
CITYOFCARLSBAD
2075 Las Palmas Dr., Carlsbad CA 92009 (619) 43&-1161
PERMIT APPLICATION
City of Carlsbad Building Department
2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161
1. PERMIT TYPE
"A • COMMERCIAL QNEW •TENANT IMPROVEMENT
B - • INDUSTRIAL QNEU ^TENANT IMPROVEMENT
C - DRESIDENTIAL DAPARTMENT •CONDO nsiNGLE FAMILY DUELLING •ADDITION/ALTERATION
• DUPLEX •DEMOLITION •RELOCATION •MOBILE HOME •ELECTRICAL QPLUMBING
• MECHANICAL •POOL QSPA QRETAINING WALL QSOLAR •OTHER.
2. PROJECT INFORMATION PLAN CHECK NO.
EST. VAL
PLAN CK DEPOSIT
VALID. BY ^
DATE
-rt
='7'51 i?//^7/P0 0001 01 02
^.^ ^. C-PRMT 334.00
(?H 56^0
FOR OFFICE USE ONI Y Address
Nearest Cross Streets
LOy-^Sie. P^e-- Building or suite NO.
LEGAL DESCRIPTION Subdivision Name/Number
CHECK BELOU IF SUBMITTED:
0'; Energy Calcs •; Structural Calcs I I 2 Soi Is Report p^l Addressed Envelope
EXISTING USE PROPOSED USE ASSESSOR'S PARCEL ^CP ^ <^ fe) (D ^
DtSLR.PnON WORK Cf^^t^^f^ f\j ^(^^^ ^ f^^^O i ^t^C, . &X/^ r ^) /^£7 V/^/ ^ l~f
BLDG. SQ. FTG. ^'g , Q ~?> * OF STORIES
3. CONTACT PERSON
NAHE ^lCA^y:>r(2^ VI(^•^O H ADDRESS 2 3^^ CyhtmilVO ///i^A /2<7l&(^ /O-7
STATE (i^^ ZIP CODE DAY TELEPHONE >f 3 ^ '5"/'^/
4. APPLICANT •CONTRACTOR
NAME
"z^Mmi^ Afc- A/^c7VC
• AGENT FOR CONTRACTOR
ADDRESS
• OWNER • AGENT FOR OWNER
DAY TELEPHONE
5. PROPERTY OWNER
NAME TecH /&/C-T" C^yyv^T «^57er-^-
ciTY^An^ r>ir^o
[^LESSEE •TENANT
STATE ZIP CODE ^1^11 C DAY TELEPHONE Q <^ 22 3 II ^ 3
6. CONTRACTOR
NAME ADDRESS
ZIP CODE DAY TELEPHONE
STATE LIC. # LICENSE CLASS CITY BUSINESS LIC. *
DESIGNER NAME^^;^^-]-: ^l^^/i. /IX/C
CITY d^^yf^^/^a
ADDRESS 2 3 ^'5' d^yn^i^ S//^A iZ^tU^ /O-J
ZIP CODE Zi^C^ DAY TELEPHONE ^ / cf ^"7*^ / STATE LIC. *0\^'^'Z^
WORKERS' COMPENSATION
Workers' Compensation Declaration: 1 hereby affirm that I have a certificate of consent to self-insure issued by the Director of Irvdustrial Relations,
or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the
insurer thereof filed with the Building Inspection Department (Section 3800, Lab, C).
INSURANCE COMPANY POLICY NO. EXPIRATION DATE
Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner
so as to become subject to the Workers' Compensation Laws of California.
8. OWNER-BUILDER DECLARATION
Owner-Builder Declaration: hereby affirm that 1 am exempt from the Contractor's License Law for the following reason:
|~~] I as owner of the property or my enployees with wages as their sole compensation, will do the work and the structure is not interxJed or offered for sate
(Sec. 70^4, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon,, and who
does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building
or improvement is sold within one year of completion, the owner-builder will have tho txjrden of proving that he did not build or improve for the purpose
of sale.).
r~] I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code:
The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s)
licensed pursuant to the Contractor's License Law).
Q I am exempt under Secti Business and Professions Code for this reason:
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure,
prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the
Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom,
and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not
more than five hundred dollars [$500]).
SIGNATURE DATE
COMPLETE THIS SECTION FOR NON-RES I DENT 1AL BUILDING PERMITS ONLY:
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Prcslcy-Tanner Hazardous Substance Account Act?
• YES • NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?
• YES GNO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site?
• YES •NO
IF ANY OF THE AMSUERS ARE YES. A FINAL CERTIFICATE OF OCCUPANCY KAY NOT BE ISSUED AFTER JULY 1, 1989 UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS
OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
9. CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the woric for which this permit is issued (Sec 3097(i) Civil Code).
LENDER'S NAME LENDER'S ADDRESS
10. APPLICANT'S SIGNATURE certify that I have read the application and state that the above information is correct. I agree to comply with all City ordinances and State laws relating
to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO
AGREE TO SAVE INDEMNIFY AND ICEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES. JUDGMENTS. COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID
CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null arxi void if the building
or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended
or abandoned at any time after the work is commenced for a period of 180 days (Section 303Cd) Uniform Building Code).
• OWNER Q CONTRACTOR
/7 1 /r/
APPROVED BY:
DATE;
WHITE: File YELLOW: Applicant PINK: Finance
PERMIT APPL^AJION
City of"Carlsbad Building Department
2075 Las Palmas Dr., Carlsbad, CA 92009 (6i9) 438-u6i
1. PERMIT TYPE |
GNEW •TENANT IMPROVEMENT '
• NEW • TENANT IMPROVEMENT
• APARTMENT •CONDO QSIMGLE FAMILY DUELLING
A - •COMMERCIAL
B - •INDUSTRIAL
C - nRESIOENTIAL QAPARTMENT •CONDO QSIMGLE FAMILY DUELLING •ADDITION/ALTERATION
• DUPLEX nDEMOLITION •RELOCATION nMOBILE HOME nELECTRICAL DPLUMBING
• MEPHANICAL nPOOL nsPA ^RETAINING UALL GSOLAR GOTHER. MEPWANICAL •POOL QSPA GRETAINING UALL GSOLAR DgTHER^ I , ^
JECT INFORMATION PLAN CHECK NO.
~Building or Suite No.
EST. VAL_
PL** OC DEPOSIT_
VALID. BT
DATE
R OFFICE USE ONI Y
LEGAL DESCRIPTION Lot No. Subdivision Name/Nurt>er Unit No. Phase No.
CHECK BELOW IF SUBMITTED:
• 2 Energy Calcs G2 Structural Calcs G^ Soi Is Report Ql Addressed Envelope
ASSESSOR'
BESCRIPl
EXISTING USE PROPOSED USE
WORK
^^^^ /A)-^ ^>^/^^^«fc>t^
BLDG. SO. FTG. # OF STORIES
3. CONTACT.
NAME ADDRESS
ZIP CODE DAY TELEPHONE
Workers' Compensation Declaration: I hereby affirm that I have a certificate of consent to self-insure issued by the Director of Industrial Relations,
or a certificate of Workers' Compensation Insurance by an adnitted insurer, or an exact copy or duplicate thereof certified by the Director of the
insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C).
INSURANCE COMPANY POLICY NO. EXPIRATION OATE
Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner
so as to become subject to the Workers' Compensation Laws of California.
8. OWNER-BUILDER DECLARATION Owner-Builder Declaration: I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
G I as owner of the property or my emptoyees with wages as their sole compensation, will do the work aryj the structure is not intended or offered for sale
(Sec. 7DA4, Business and Professions Code: The Contractor's License Law does not a|3ply to an owner of property who builds or improves thereon,, evA who
does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building
or improvement is sold within one year of completion, the owner-bu? I der will have the burden of proving that he did not build or improve for the purpose
of sale.).
G 1/ as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code:
The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s)
licensed pursuant to the Contractor's License Law).
G 1 am exempt under Section Business and Professions Code for this reason:
<Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure,
prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the
Contractor's License Law (Chapter 9, coinnencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom,
and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not
more than five hundred dollars [$500]).
SIGNATURE DATE
COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY:
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act?
QYES GNO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?
GYES GNO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site?
GYES •NO
IF AMT OF THE ANSWERS ARE TES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1, 1989 UNLESS THE APPLICANT HAS MET 0« IS MEETING TME REOUIRENENTS
OF THE OFFICE OF EMERGENCY SERVICES ANO TME AIR POLLUTION CONTROL DISTRICT.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code).
LENDER'S NAME LENDER'S ADDRESS
10. APPLICANT'S SIGNATURE I certify that I have read the application and state that the above information is correct. I agree to comply with all City ordinances and State laws relating
to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO
AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY UAY ACCRUE AGAINST SAID
CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
Expiration. Every permit issued by the Building official under the provisions of this Code shall expire by limitation and become null and void if the building
or work authorized by such permit is not coranenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended
or al^ndoned ^ any time %*fe^the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code).
«i^>.^IGNATURE I ^ |„ n QCONTRACTOR • BY PHONE APPROVED BY:
DATE:
WHITE: File YELLOW: Applicant PINK: Finance
CITY OF CARLSBAD
' INSPECTION REQUEST
PERMIT* CB901918 FOR 01/24/91
DESCRIPTION: MOVE ELEC/ADDING WALLS
LA COSTA PRODUCTS, PERSONAL CARE MFG
TYPE: ITI
JOB ADDRESS;
APPLICANT:
CONTRACTOR:
OWNER:
2875 LOKER AV EAST
TECHBILT CONSTRUCTION CORP
WHITE CONSTRUCTION
REMARKS: RS/TRAVIS/753-9272
SPECIAL INSTRUCT:
PHONE:
PHONE:
PHONE:
INSPECTOR AREA TP
PLANCK* CB901918
OCC GRP
CONSTR. TYPE VN
STR: FL: STE:
619 223-1163
619-753-9272
INSPECTOR
TOTAL TIME:
—RELATED PERMITS— PERMIT* TYPE
C0900039 COFO
CB910091 MECH
STATUS
ISSUED
ISSUED
CD LVL DESCRIPTION
19 ST Final Structural
29 PL Final Plumbing
39 EL Final Electrical
49 ME Final Mechanical
ACT COMMENTS
***** INSPECTION HISTORY *****
DATE DESCRIPTION ACT INSP COMMENTS
012291 Final Structural CA TP
012291 Final Electrical CA TP
011891 Rough Electric AP TP TRANSFORMER SET
011191 Frame/Steel/Bolting/Welding AP TP T-BAR
011191 Rough Electric AP TP CEILING
011191 Rough/Ducts/Dampers AP TP CEILING
011091 Rough Combo AP TP T-BAR (ONE ROOM ONLY)
011091 Rough Electric AP TP
011091 Rough/Ducts/Dampers AP TP
010491 Interior Lath/Drywall AP TP
010391 Frame/Steel/Bolting/Welding AP TP WALLS ONLY
010391 Underground/Under Floor AP TP
010391 Rough Electric AP TP WALLS ONLY
010391 Sewer/Water Service AP TP TO 4" LINE
010391 Rough/Topout AP TP
UNSCHEDULED INSPECTION
DATE s/cP'S'^'f/ fA*^ INSPECTOR T^^T"
PERMIT # PLANCK #
JOB ADDRESS -Z-fjl ^ L o Kjt "7^^
TIME ARRIVE: TIME LEAVE:
CD LVL DESCRIPTION ACT COMMENTS
10/2 Tom Doyle says they got letter from Slemans and gave It to
Pat Kelley irtio approved the work. Carter
March 28, 1991
Vince Blumenfeld BSD
6104 Avenida Endnas Suite A
Carlsbad, CA 92008
Subject: ITE/Slemens S.0.# 60-92059-1 and $.0.# 60-90453-1
2875 Loker East
Carlsbad, CA
Dear Vir\ce,
It is acceptable to cable tap the existing underground section providing the
new additional lOOamp service does not exceed the rating of the existing service.
It is acceptable for the contractor to drill and tap the bus, install lugs for
cabling and torque lugs per attached recommendation.
Thank you,
Bob falar
Sales Engineer
BF/ab
fels^Mw't^'cfai^o'^^Rc^^^ • Te;: (519) 569-6015 • FAX: (519) 2'/9-3453
TS'd S6S8T£6 Oi 0931a NbS SH3W31; :d TS.:9T T.66T.-£;S-aW
>: Til 2 19 9 1 10:42 R 0 M F R 0 S P E S S I H E ELECTRIC CO.
\n 1
TO 438 0 894 P. 01
Pro^essive Electric Co,
590 Aygusra Dr.
San Marcos
CA ')20G'-)
Telephone: (619) 741-1593
Facsimile: (619)480-6624
License # 469198
I* * * V; f." *********<•*************'*******«*********************************
^ ^ ^ * , * * A * -Ir * * * * >v * -/r * * * * * V' * :V * * * * * + * * * * * A
Toto" Paqes Includirig
FAX COVER SHEET
This C:iy ^
10
^e/)>r Fcf^ ^S'^-O S^/
Re
-hurn^<^ -^^^ ^^'^ J^^-
CM
RCU BY:XEROX TELECOPIER 7010 ;10- 2-91 ll:39fiM ; CCITT S3^ J2
10/02/1991 10:43 FROM PROQRESSIUE ELECTRIC CO. TO 4380894 P.02
March 28, 1991
Vince Blumenfeid
ESD
61(54 Avenida Endnas Suits A
Carlsbad, CA 92008
Subject: ITE/Siemens S.O.f^ 60-92059-i a.nd $.0.# 60-90453-1
2875 LQker EdSt
Carl?:bad, CA
Dear Vince,
U Is acceptable to cable Up Lhe existing underoround section providing t^e
nev-/ additional lOOamp service does not exceed the rating of the existing service.
It is acceptable for the contractor to drill and tap the bus» install lucjs for
cablina and torq^ie lugs per attached reconn^'endation.
Thank you.
Sob fauf
Sales Enfineer
BF/ab
ROJ EY: XEROX TE!_£r;QpTF;^ 7013 ; 13- 2-91 11:390'-'' ;
1 Of 02/1991 10:43 'R0!^ PROSRESSIUE ELECTRIC CO.
Itt 3
TO 4380894 P. 03
PANEL:W i
VOLTS:120/208
AMPSJ 200
PHASE!3,4W
MAIN! 200A
W P
C A H T P
IT A R O
R T S I L
C S e P E .DESCRIPTION
W P
C A H T P
IT A R 0
R T S I L
C S E P E DESCRIPTION
5280 60 3 DRYER BELT 2 1250 1a£ 20 3 COMPRESSOR
5280 60 3 DRYER BELT 4 1250 3 20 3 COMPRESSOR
5280 3 60 3 DRYER BELT 6 1250 20 3 COMPRESSOR
/ i. 30 SILK SCREEN 8 SOO i 20 5. DROP CORDS
3 2520 1 30 2 SILK SCREEN 10 800 1 20 1 DROP CORDS
11 1 20 1 COMPRESSOR 12 SOO 1 20 1 DROP CORDS
13 .1500 i 20 1 HEATER 14 725 3 20 3 MIXER 1
15 1500 1 20 X STEAMER 1S 725 3 20 MIXER 1
17 1500 1 20 1 STEAMER 18 725 3 20 5 MIXER 1
19 1440 1 20 JLL niXER 20 725 3 20 3 MIXER 2
1 1 440 4 X 20 •~t J-MIXER 22 725 3 20 3 MIXER 2
800 1 20 1 WHSE RECPT 24 725 20 3 MIXER 2
25 800 1 20 1 WHSE RECPT 26
27 L=:00 1 20 WHSE RECPT 28
29 800 i 20 1 WHSE RECPT 30
3i 300 1 20 1 WHSE RECPT 32
"^'^ O 800 '( 20 1 WHSE RECPT 34
35 36
37 38
39 40
4J 42
PHASE A i^ATTS 15840 PHASE A AMPS
PHASE e WAT TS 15S40 PHASE B AMPS
PHASE WAT TS i 2840 PHASE C AMPS
132.00
132.00
i 07.OO
TOTAL WATTS 44520
./ ^ — c-; p c ^ c: ;tt 4
)e'^02-199 1 10:44 FROM PROGRESS I UE ELECTPI' CO . TO 438 0 894 P . 84
FINAL BUILDING INSPECTION RECEIVED JAN 2 3 1991
DEPT: BUILDING ENGINEERING FIRE PLANNING U/M WATER
PLAN CHECK# :C:X:B9019^^
PERMIT*: CB901918
PROJECT NAME: MOVE ELEC/ADDING WALLS
LA COSTA PRODUCTS, PERSONAL CARE MFG
ADDRESS: 2975 LOKER AV EAST
CONTACT PERSON/PHONE#: MH/TRAVIS/753-9272
SEWER DIST: CA WATER DIST: CA
DATE: 01/23/91
PERMIT TYPE: ITI
INSPECTED
BY: A. haJlcJL^
INSPECTED
BY:
INSPECTED
BY:
DATE
INSPECTED:
DATE
INSPECTED:
DATE
INSPECTED:
(_ APPROVED _JC DISAPPROVED
APPROVED
APPROVED
DISAPPROVED
DISAPPROVED
COMMENTS:
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO. CA 92123
(619) 560-1468
DATE:
JURISDICTION: OoX U borj
PLAN CHECK NO; 90-|9lfe SET: IT
PROJECT ADDRESS:
PROJECT NAME; La C^SC^r^. PmAu^C^T.^ T, T
• APPLICANT
8JURISDICTION
PLAN CHECKER
• FILE COPY
• UPS
• DESIGNER
•
•
•
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with the jurisdiction's building codes when minor deficien-
cies identified are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
•
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
j I The applicant's copy of the check list has been sent to:
r j Esgil staff did not advise the applicant contact person that
plan check has been completed.
•| Esgil staff did advise applicant that the plan checkihas ^
^ been completed. Person contacted; ^|/}>^x'^~ CVy^lC jS^JrrJyy, Ty
Date contacted
REMARKS; iVl
Telephone # Ov\ persr;>Y\
By:
ESGIL CORPORATION I;^^<^-(^
• GA DAA DRN GDM
Enclosures:
- ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 560-1468
DATE; (CL/ on j So nAPPLICANT
' rr j \ j HJURISDICT
JURISDICTION: Ciarkbrvrl
PLAN CHECK NO; 9Q— \ 9 \^ SET: ^
PROJECT ADDRESS; d^lS, L<^l<Cr A-Vg .
PROJECT NAME; LQ^ GoS'hX PTOGIUC-V^ X I.
JURISDICTION
PLAN CHECKER
FILE COPY
• UPS
• DESIGNER
•
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
I—I The plans transmitted herewith will substantially comply
I I with the jurisdiction's building codes when minor deficien-
cies identified are resolved and
checked by building department staff.
•
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
•
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
HH The applicant's copy of the check list has been sent to:
1 ' 3^200 9
Esgil staff did not advise the applicant contact person that
— plan check has been completed.
Esgil staff did advise applicant that the plan check has
been completed. Person contacted; T^loVl<r\ yJ\<7f^rv\
Date contacted; VliOSl I9Q Telephone # 4'g>fe--^l9|
Q REMARKS:
By-0\jLdip\}U.^^S^ Enclosures;
ESGIL CORPORATION T«2^2^^9^
•GA DAA DRN QDM
CAL
I'lt^lan'showing location of all^panels.TI
Submit panels schedules.
Submit electrical load calculations
Indicate existing main service size.
Indicate existing total main service load.
Indicate new additional loads.
\Indicate wiring method, i.e. tKl, metal flex.
•Shew—exit—signs—eo—the—eleetrieal lighting
to«(3). As per Section 3313 and. 33U of the
1988 UBC, provide two sources of power to exit
signs anri.PYit iUuminntionFoR. ClK]t> Ft-OaH BX\\S
.Tl-i IS
Provide receptacle(s) within 25' of the roof
mounted A/C units. UMC Section 509.
Provide multiple switch lighting controls per
•itle 24, 2-5319. ^Hou3 WOL-nPUE. .SuOiTCrt-
Gowre^JLi owTi-4- ri-4
Provide an electrical plan for the alarm system
showing compliance with criteria described
under earlier correction number 54.
MECHAKICAI.
'rovide mechanical ventilation in all rooms
capable of supplying a minimum of 5 cubic feet
per minute of outside air with a total
circulation of not less than 15 cubic feet per
aipute per occupant. Section 605 and 705, UBC.
2«,c ji**/ mT)-^ Provide mechanical plans showing existing and
proposed HVAC equipment, ducts and access to
equipment.
Detail access
equipment.
and working clearances to HVAC
'6.
oling coils or cooling units located in attic
or furred space, vAiere damage may result from
condensate overflow, shall be provided with an
additional water tight pan of corrosion
resistant material to catch overflow if primary
condensate drain becomes clogged. Section
1205, UMC. Ge»LiM^ ^^MTEo FA/0 COILS
One-hour corridors shall not be used as an
integral part of a duct system. Ihis includes
the space abovo a dropped ceiling within the
one-hour corridor. UMC Section 706(b).
rLOMBIHS
•
Provide gas line plans and calculations,
showing pipe lengths and gas demands. UPC
Section 1219. p _ y
rovide drain, waste and vent plans.
Provide water line sizing calculations.
Section 1009. UPC
Detail how floor drain trap seal is to be
maintained. UPC Section 707 (floor drain trap
priiBing).
Show P & I valve on water heater and detail
drain line route from P & X valve to the
exterior. UPC Section 1007(e).
Show 1/4" per 12" slope
lines. UPC Section 407. on drain and waste
Provide a drinking fountain at each floor
level in assembly occupancies (except drinking
and dining establishments). UBC Section 605.
ENERGY
rovide complete energy design calculations,
including all existing design and new energy
design for this building. See attached non-
residential energy design checklist.
For remodels in an existing conditioned space,
.show that the remodeled space will not use
Eorc energy tJvan the existing space or show
tlie remodeled .^pace will conform to latest
energy design st.ar.dar(is.
Please see additional
that follow. corrections or remarks
o speed up the recheck process, note on this
list (or a copy) whee each correction item has
been addressed, i.e., plan sheet, note or
detail number, calculation page, etc.
Please indicate here if any changes have been
made to the plans that are not a result of
corrections from this list. If there are
other changes, please briefly des::ribe them
and v^ere they are located in the plans.
Have changes been made to the plans not
resulting from this correction list? Please
check.
Yes No
4/5/90
FLAN 00RR£XXi:0N SaEEOC
J[ORISDI(«a(: QAIE: //- ?g
PLAH COKaC WIHBER; ^ ^ " 19 /
GL£K ADAMSC
FLAK aiEOOEK: Q CART AMCEL
•
•7^/< A/grtQ Mc^At /^u^/:} gg.^ /<> /Ugr .^A/<acJ/J /<J
/7
cprji-y ^ 9>Z so
otjfoei /)/^/i.fAj £<JA<;r<f /^O/O l/cS^^Jr g
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 560-1468
DATE:
JURISDICTION:
PLAN CHECK NO: 1919^ SET: X
PROJECT ADDRESS; L ,C) kcP /V\Je .
PROJECT NAME: Ll dn^^T. PrcAl KC TT,
QAPPLJ
tISDICTIOt
IJ PLAN CHECKER
• FILE COPY
• UPS
nDESIGNER
•
•
•
•
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with the jurisdiction's building r:odes when minor deficien-
cies identified are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a^complete recheck.
The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to;
Esgil staff did not advise the applicant contact person'^that '
plan check has been completed.
f I Esgil staff did advise applicant that the plan check has
been completed. Person contacted:__
Date contacted;
Q REMARKS:
Telephone #_
By:Pjig(jclf\jt^W(L Enclosures:
ESGIL CORPORATION iC2L/,o/cNf>
•GA DAA • RN QDM
PIAW COKRECTIOW SHEET
TENANT IMPROVBfENT
FI.AN CHECK NO.:.
JURISDICIXON:
10:_
Date plfuis received by jurisdiction:
Date plans received by Esgil Corporation:
1^/ I0/9Q
Date initial plan check completed
C^A L( ck UeviAeu W i 1
PROJECT DATA Applicant contact person:
OOCUPANOT:
HnLDING USE:
IXPE OF OMiSIRDCnON:
FDREWMO); PLEASE READ
ACmAL AREA:
Q o\ \ r A Pls-n check is limited to technical requirements
contained in the Uniform Building Code, Uniform
ALLOHAHLE AREA:
SKXilES:
HEIGHT:
IE
SFRINKLERS: V
OCCOFAKr LOAD: 3s:
DSMARKS:
Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the
handicapped. The plan check is based on
regulations enforced by the Building Inspection
Department. You may have other corrections based
on laws and ordinances enforced by the Planning
Department, Engineering Department, Fire Department
or other departments. Code sections cited are
based on the 1988 UBC.
The circled items listed need clarification,
modification or change. All items must be
satisfied before the plans will be in conformance
with the cited codes and regulations. Per Sec.
303(c), 1988 Uniform Building Code, the approval of
the plems does not permit the violation of cuiy
state, county or city law.
To speed up the recheck process, note on this list
(or a COPY) where each correction item has been
addressed, i.e.. plan sheet, specification, etc.
Be sure to enclose the meurked up list when vou
submit the revised plfins.
IKnX: PAGE MIMBERS ARE NOT IH SEQOENCB AS PAGES HAVING NO IIEHS NEEDING OffiRECIKXIS WERE DELECED.
LIST NO. 58 TENANT IMPROVEMENT WITHOUT SPECIFIC ENERGY ZONE DATA OR POLICY SUPPLIMENTS, 1988 UBC
/TT^ please'-make all corrections on the original
tracings and submit two new sets of prints, and
any original plan sets that may have been
returned to you by the jurisdiction, to:
Esgil Corporation, 9320 Chesapeake Drive,
Suite #208, San Diego, CA 92123,
(619) 560-1468.
Please make all corrections on the original
tracings and submit two new sets of prints, and
any original plan sets that may have been
returned to you by the jurisdiction, to:
The jurisdiction's building department.
Indicate on the Title Sheet of the plans, the
name of the legal owner and name of person
responsible for the preparation of the plans.
Section 302(d).
Each sheet of the plans must be signed by the
person responsible for their preparation, even
though there are no structural changes.
Business and Professions Code.
/
Plans and calculations shall be signed by the
Califomia state licensed engineer or architect
where there are structiural changes to existing
buildings or structural additions. Please
include the Califomia license ntaiber, seal,
date Of license ^jxpiration and date plauis are
signed. Business and Professions Code.
Provide the correct address and suite number of
tenant space on the plans. Section 302(d).
Provide a note on the site plan indicating the
previous use of the tenant space or building
being remodeled. Section 302.
When the character of the occig>ancy or use
changes within a building, the building must be
made to comply with current Building Code
requirements for the new occupancy. Please
provide complete details to show the building
with comply. Section 502.
UBC Section 304 requires tha Building Official
to determine the total value of all
construction work proposed iinder this permit.
.The value shall Ijtclude all finish work,
painting, roofing, electrical, plumbing,
heating, air conditioning, elevator, fire
extinguishing systems and any other permanent
equipment. Please provide a signed copy of the
designer's or contractor's construction cost
estimate of all work proposed.
Provide a plot plan showing the distance from
the building to the property lines and the
location of tenant space (or remodel) within
the building.
0
On the first sheet of the plans indicate:
Type of construction of the existing building,
present and proposed occupancy classifications
of the remodel area and the occupant load of
the remodel areas and the floor where the
tenant improvement is located.
Provide a note on the plans indicating if any
hazardous materials will be stored and/or used
within the building which exceed the
quantities^ listed in UBC Tables 9-A and 9-B.
A complete description of the activities and
processes that will occur in this tenant space
should be provided. A listing of all
hazardous materials should be included. The
materials listing should be stated in a form
that would make classification in Tables 9-A
£md 9-B possible. The building official may
require a technical report to identify and
develop methods of protection from hazardous
materials-. Section 901(f). _
KN\6 \0G5, lOfej 109
If control areas eure used for exceeding the
exempt amounts of hazardous materials from
Tables 9-A and 9-B, they shall be constructed
of not less that required for a one-hour
occupancy separation. Section 404.
The riumber of control sreas within a building
useo for retail/wholesale stores shall not
exceed twoj the number of control areas in
buildings with other uses shall not exceed
four. Footnote 1, Tables 9-A and 9-B.
16. ] The aggregate quantity of any hazardous
V. y materials "in use" and "in storage" shall not
exceed the quantity listed in TnMac. o M^H]
9-B for "storage". Footnotes 2 and 3, Tables
9-A and 9-B. ^TO«.fVG^£ 16^ 4 <^EKJ.
Provide a statement on the Title Sheet of the 3A
plans that this project shall comply with I
Title 24 and 1988 UBC, UMC and UPC and 1987 '
NEC.
Provide a fully dimensioned floor plan showing
the size and use of all rooms or areas within
the space being iinproved or altered. Draw the
plans to scale and indicate the scale on the
plan. Section 302(d).
Indicate the use of all spaces adjacent to the
area being remodeled or improved.
Show any existing fire rated area separation
walls, occiip2uicy separation walls, demising
walls, shafts or rated corridors. Identify
and provide construction details for proposed
new fire rated walls.
Specify on the plfuis the fire ratings of
assemblies to protect proposed openings in
existing or new fire walls.
12/29/89
Identify existing walls to be removed, existing
walls to remain and proposed new walls.
Identify beaxing walls, non-bearing walls, and
shear walls.
Provide a
partitions.
section
Show:
view of all new interior
0
(a) Type, size and spacii^ of studs. Indicate
gauge for metal studs. Specify
manufacturer and approval number or
indicate "to be ICBO approved".
(b) Method of attaching top and bottom plates
to structure. (NOTE: Top of partition
must be secured to roof or floor framing,
unless suspended ceiling has been designed
for partition lateral load).
(c) Wall sheathing material and details of
attachment (size and spacing of
fasteners).
(d) Show height of partition and suspended
ceiling, and hei^t from floor to roof
framing or floor framing.
Provide notes and/or details to show that the
floor and wall finish in toilet rooms are
surfaced with a smooth hard non-absorbent
material extending five inches up the wall.
Simileir surfacing shall be provided on the
walls from the floor to a height of 4 feet
around urinals and within water closet
compartments. Section 510(b).
Note on the plans: "All interior finishes must
coinply with Chapter 42 of the UBC". Specify
"ClassJ ^1^^^ ^j^£Ar^^^^ rating (minimum)
Lateral bracing for suspended ceiling must be
provided. (UBC Table 23-P) Where ceiling is
not supporting interior partitions, ceiling
bracing shall be provided by fotu: No. 12 gauge
wires secured to the main runner within 2
inches of the cross ninner intersection and
splayed 90 degrees from each other at an angle
not exceeding 45 degrees from the plane of the
ceiling. A strut (adequate to resist the
vertical component from lateral loads) fastened
to the main runner shall be extended to and
f2istened to the structural members of the roof
or floor above. These horizontal restraint
points shall be placed 12 feet o.c. in both
directions with the first point within 6 feet
of each wall. Attachment of restraint wires to
the structure above shall be adequate for the
load imposed. UBC Standard 47-18.
0
In buildings having floors and roofs of wood
frame construction, other ttian dwelling or
hotel occupancies, draft stop the area between
the ceiling and floor above so that no
concealed space exceeds 1,000 s.f. and no
horizontal dimension exceeds 60 L.F. (if space
has sprinklers, then 3,000 s.f. and 100 L.F.).
Section 2516(f).
In buildings having floors mi ueefa of wood
frame construction, other than dwelling or
hotel occupancies, draft stop the area between
the ceiling and roof above so that no
concealed space exceeds 3,000 s.f. and no
horizontal dimension exceeds 60 L.F. (if space
has sprinklers, then 9,000 s.f. and 100 L.F.). /• /•
Section 2516(f).
Storage areas exceeding 1000 sq. ft. in
connection with wholesale or retail sales
shall be separated from the public area by a
one-hour occupancy separation. If the entire
building has an automatic sprinkler system,
then the occupemcy sepauration need not be
provided.
An automatic sprinkler system shall be
installed in rooms used by the occupants for
the consumption of alcohol and in accessory
uses vhere the total area of such unseparated
roocs eind assembly uses exceeds 5000 square
feet. Section 3802(c).
The tenant space and new and/or existing
facilities serving the remodeled area must be
accessible to and functional for the
physically disabled. See the attached
correction sheet. Title 24, Part 2.
Ths width of the required level area on the
side into which doors swing shall extend 24
inches pzist the strike edge for exterior doors
and 18 inches past the strike edge for
interior doors. Section 2-3304, Title 24.
Specify lever-type haurdware for passage doors
on floors accessible to the disabled. Section
2-3304, Title 24.
If both sexes will be en^loyed and the number
of employees exceeds four, provide separate
toilet facilities for men and women. If "both
sexes will be employed and the total number of
employees will not exceed four", eind only one
restroom is provided, note the words in
quotation above on the floor plan. Section
705.
In areas where the occupant load exceeds
two exits are required. See
. Table 33-A.
2/15/90
X provide an exit analysis plan (may be 8 1/2" x Jn.
11" 01? any convenient size). ^
Exits should have a minimum separation of one-Exits should have a minimum separation of one-
half the maximum overall diagonal dimension of
the building or area served. Section 3303(c).
The maximum number of required exits and their
required separation must be maintained until
egress is provided from the structure. Section
3303(a).
Rooms with more than 10 occupants may have one
exit through one adjoining room. Revise exits
to comply. Section 3303(e).
ka. Exit signs are required for exits serving an
/ occupsmt load exceeding 49. Show all required
exit sign locations. Section 3314(a).
Show that exits are lighted with at least one
foot candle at floor level. Section 3313(a).
42. Show the locations of existing exits from the
/ building and show the path of travel from the
remodel area to the existing exits.
Note on the plans: "All exits are to be
openable from inside without the use of a key
or special kr.ovledge". In lieu of the above,
in a Group B occupancy, you may note ''Provide a
sign on or near the exit doors readi:;;? THIS
DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS".
This signage is only allowed at the main exit.
Section 3304(c).
Exit doors should be a minimum size of 3 feet
by 6 feet 8 inches with a minimum door swing of
90 degrees. Maximum leaf width is 4 feet.
Section 3304(f).
Exit doors should swing in the direction of
egress when serving an occupant load of 50 or
more or when serving any hazardous aurea.
Section 3303(b). Applies to door(s)
Regardless of occupant load, a floor or landing
not more than 1/2 inch below the threshold is
required on each side of an exit door used for
disabled access (may be 1" maximum vAiere not
,^ used for disabled access). Section 3304(i).
Doors should not project more than 7 inches
into the required corridor width when fully
opened, nor more theui one-half of the required
corridor width when in any position. Section
3305(d).
Revolving, sliding and overhead doors are not
permitted as exit doors if the occupant load
exceeds 9 or the exit door serves a hazardous
area. Section 3304(h).
Exit doors from assembly rooms with 50 or more
occupants shall not be provided with a latch
or lock tinless it is panic hardware. Section
3318.
Double acting doors are not allowed when
serving a tributary occupemt load of more than
100, or when part of a fire assembly, or part
of smoke and draft control assemblies or when
equipped with panic hardware. Section
3304(b).
Corridors must provide continuous protection
to the exterior of the building.
Interruptions by an intervening room is not
permitted. Foyers, lobbies or reception rooms
constructed as required for corridors are not
considered intervening rooms. Section 3305.
Corridors and exterior exit balconies serving
10 or more occupants must be a minimum 44
inches wide and 7 feet high to the lowest
projection. Corridors serving less than 10
occupemts must be a minimum of 36 inches in
width. Section 3305(b).
When two exits are required, dead end
corridors and exit balconies are limited to 20
feet. Section 3305(e).
Corridors serving 30 or more occupants shall
have walls and ceilings of one-hour
construction except:
a. Corridors greater than 30 feet wide when
the occupants have an exit independent
from the corridor.
b. Exterior sides
balconies.
of exterior exit
Corridor walls and ceilings need not be
of fire-resistive construction within
office spaces having an occupant load of
100 or less when the entire story in
vhich ths space is located is equipped
with an automatic sprinkler system
and smoke detectors are
within the corridor in
with their listing. Section
throughout
installed
accordance
3305 (g).
Section 3305(g), Exception 5, cannot be used
for non-rated corridors in a fully sprinklered
office space if the occupant load in the space
exceeds 100.
Section 3305(g), Exception 5 does not apply to
common corridors where the corridor serves as
an exit for non-office eureas (msuiufacturing,
warehouse, etc.).
2/14/90
Section 3305(g), Exception 5 is applicable only
for corridors on one floor; the corridors on
th4 lower 'level(s) must be rated if these lower
corridors have openings into them from other
levels.
If non-rated corridors are used per Section
3305(g), Exc. 5, provide a reference to the
corridors on the floor plan, noting:
1. Corridors are non-rated per Section
3305(g), Exception 5.
Smoke detection system must be listed by
the State Fire Marshall and be a
supervised low voltage system.
Smoke detectors
center.
shall be maximum 30' on
4. Power supply shall be dedicated branch
circuit. Circuit disconnecting means
shall be accessible only to authorized
personnel and shall be clearly marked FIRE
ALARM CIRCUIT CONTROL, with a lock-on
device.
If a tenant space utilizes Section 3305(g),
Exception 5, then that tenant space shall be
separated from adjacent spaces by a demising
wall constructed as for a one-hour corridor
wall.
60. Clearly show vrtiere the non-rated corridor
/ system terminates and a rated corridor system
commences.
One-hour fire-rated corridors shall have door
openings protected by tight-fitting smoke and
draft control assemblies rated 20 minutes,
except openings in interior walls of exterior
exit balconies. Doors shall be maintained
self-closing or be automatic-closing by action
of a smoke detector per Section 4306(b). Doors
shall be gasketed to provide a smoke and draft
seal where the door meets the stop on sides and
top. Section 3305(h).
Show rated corridors, lobbies, reception or
foyers cross-hatched on the floor plans.
Total area of all openings, except doors, in
any portion of an interior corridor, shall not
exceed 25 percent of the area of the corridor
wall of the room v4iich it is separating from
the corridor. Such openings shall be protected
by fixed, approved 1/4 inch thick wired glass
installed in steel frames. Section 3305(h).
Provide a complete architectural section of
the corridor, or exterior exit balcony,
showing all fire-resistive materials and
details of construction for all floors, walls,
ceiling and all penetrations. Section
3305(g).
Show the location of fire dampers. Provide
fire dampers at duct penetrations of fire-
rated occupemcy and area separations, shafts
and corridor walls and ceilings. Section
4306(j).
If a room with an exhaust fan has a door
opening into a rated corridor, show how make-
up air will be provided to the room. The door
cannot be undercut, nor can a louver in the
door be provided. Section 3305(h)l.
If building exceeds two stories and has an
elevator opening into a rated corridor, show
how the smoke and draift control provision of
Section 3305(h) will be met. Either provide a
separated elevator lobby or a second door at
the elevator entry meeting the provision.
If a second door is provided
entry, note that it will be
from the car side without
special knowledge or effort.
at the elevator
readily openable
a key, tool or
Section 5106.
Provide evidence of Health Department approval
(for restaurants or for tenants using X-ray
equipment).
When nonflammable supply cylinders for medical
gas systems are located inside buildings, they
shall be in a separate room or enclosure
separated from the rest of the building by not
less than one-hour fire-resistive
construction. Doors to the room or enclosure
shall be self-closing smoke- and draft-control
assemblies having a fire-protection rating of
not less than one hour. Rooms shall have at
least one exterior wall in which there are not
less than two vents of not less than 36 square
r.nches in area. One vent shall be within 6
inches of the floor and one shall be within 6
inches of the ceiling. When £ui exterior wall
cannot be provided for the room, automatic
sprinklers shall be installed within the room
and the room shall be vented to the exterior
through ducting contained within a one-hotir-
rated shaft enclosure. Approved mechanical
ventilation shall provide six air ch£uiges per
hour for the room. Section 702(b)4.
6/13/90
/•
0
ELECTRICAL
Submit'plan showing location of al Impanels.
Submit panels schedules.
Submit electrical load calculations
Indicate existing main service size.
Indicate existing total main service load.
Indicate new additional loads.
Indicate wiring method, i.e. EKT, metal flex.
-Show—exit—signs—en—the eleetrieal lighting
plan(a). As per Section 3313 and 3314 of the
1988 UBC, provide two sources of power to exit
signs and pvit illuminatian3=at^- ClMt> RJSC!)^
Provide receptacle(s) within 25' of the roof
mounted A/C units. UMC Section 509.
Provide multiple switch lighting controls per
Title 24, 2-5319. ^rt^uO WOLTlPLe. .SuOlTCH-
Provide an electrical plan for the alaunn system
showing compliance with criteria described
under earlier correction number 54.
MECHANICAL
Provide mechanical ventilation in all rooms
capable of supplying a minimum of 5 cubic feet
per minute of outside air with a total
circulation of not less than 15 cubic feet per
minute per occupant. Section 605 and 705, UBC. /=i4o (5«,t
Provide mechanical plans showing existing and
proposed HVAC equipment, ducts and access to
equipment.
Provide drain, waste and vent plans.
Provide water line sizing calculations.
Section 1009. UPC
Detail access
equipment.
and working clearances to HVAC
Cooling coils or cooling units located in attic
or furred space, where damage may result from
condensate overflow, shall be provided with an
additional water tight pan of corrosion
resistant material to catch overflow if primary
condensate drain becomes clogged. Section
1205, UMC. GeiLiM^ NAouw-mo Rv*o COILS
'6. One-hour corridors shall not be used as an
integral part of a duct system. This includes
the space above a dropped ceiling within the
one-hour corridor. UMC Section 706(b).
FLOMBINS
87.) Provide gas line plans and calculations,
showing pipe lengths and gas demands. UPC
Section 1219.
0
0
Detail how floor drain trap seal is to be
maintained. UPC Section 707 (floor drain trap
priming).
Show P & T valve on water heater and detail
drain line route from P & T valve to the
exterior. UPC Section 1007(e).
Show 1/4" per 12" slope on drain and waste
lines. UPC Section 407.
Provide a drinking fountain at each floor
level in assembly occupancies (except drinking
and dining establishments). UBC Section 605.
ENERGY
Provide complete energy design calculations,
including all existing design and new energy
design for this building. See attached non-
residential energy design checklist.
For remodels in an. existing conditioned space,
show that the remodeled space will not use
more energy than the existing space or show
the remodeled space will conform to latest
energy design standards.
Mnr.«MTKr.TAWBnrp;
Please see additional
that follow.
corrections or remarks
To speed up the recheck process, note on this
list (or a copy) whee each correction item has
been addressed, i.e., plan sheet, note or
detail number, calculation page, etc.
Please indicate here if £my changes have been
made to the plans that are not a result of
corrections from this list. If there are
otl:er changes, please briefly describe them
and where they are located in the plans.
Have changes been made to the plans not
resulting from this correction list? Please
check.
Yes No
4/5/90
NOTE:
The following provisions are contained in Title 24,
Part 1, Califomia Building Code, as adopted and
enforced by the State Fire M£u:shall. They are
provided here as a courtesy to assist designers in
developing the project documents. All applicable
provisions may not necessarily be included. Please
direct any questions regarding interpretations of
these provisions to the local Fire Department.
Walls of corridors and exterior exit balconies
in Groups A,E,I,R-1 and C Occupemcies having an
occupant load of more than six persons euid in
all other occupancies having an occupant load
of 30 or more shall be not less than one-hour
fire-resistive construction. Section 3305(g)l.
Where exit signs Jire . required by Section
3314(a), approved and listed internally,
externally or self-illuminated low-level exit
signs complying with Section 3314 shall be
required. The bottom of the sign shall be not
less than 6 inches nor more than 8 inches above
the floor level. For exit way doors, the sign
shall be on the door with the closest edge of
the sign with 4 inches of the door frame or
adjacent to the door. Such signs shall be of a
type which is perceptible to the sense of
touch. Section 3314(e).
3. Where exit signs are requirri by Section
3314(a), all exit corridors shall be provided
with continuous low-level exit path marking.
Approved and listed internally or self-
illuminated meirking shall be installed at floor
level or no higher than 8 inches above the
floor level. Such marking shall be of a type
which is perceptible to the sense of touch.
Section 3314(f).
Area separation walls shall not be considered
to create separate buildings for the purpose of
automatic fire-sprinkler system requirements as
set forth in Chapter 38. Section 505(e)6.
EXCEPIirar: Buildings separated by continuous
eurea separation walls of four-hour fire-
resistive construction without openings.
Buildings required to have automatic fire-
sprinkler protection as set forth in Section
13113 of the Health and Safety Code (homes for
children or the aged) are prohibited from using
2u:ea sepeuration walls in lieu of automatic
fire-sprinkler protection.
In educational occupancies, storage and janitor
closets shall be of one-hour fire-resistive
construction with openings protected by
assemblies having at least a three-fourths-
hour fire-resistive rating. Section 802(c).
.4?
/
The exception in Section 3318 of the UBC has
been revised so as to allow the omission of
panic hardw2u:e at the main exit in churches
(by using signage), only when the occupant
y. load of the church is less than 300.
S-8. If emergency warning systems are required,
they shall activate a me2ms of wzuming the
hearing impaired. Flashing visual wamings
shall have a frequency of not more than 60
flashes per minute.
The jurisdiction has contracted with Esgil
Corporation located at 9320 Chesapeake Drive, Suite
208, San Diego, Califomia 92123; telephone number
of 619/560-1468, to perform the plan check for your
project. If you have any questions regarding these
plan check items, please contact
Q}(\\kc\L \ke.^.^(\€>\a \ \
at Esgil Corporation
Thank you.
Enclosures:
1.
Section 1807 should be
rise buildings.
reviewed for all high-
1/8/90
PLAN CC«RBCXION SHEET
•TORISDICHOH: ^A/?L5<C!,M4J DATE; / /-
PLAN CHECK HOHBaER: "/y/^ ^ PLAM CHECKER: Q GARY ANGEL
•
A "pHd AJ(^(^ HdAf />u^f3 •^,<^ IS AJo7 .^>y<atJ/J /<J
4^0c4 / fi/^ ar/Li -r
c 'T^ci C./^'^ OK> S/-ftIcXf ^'1 Oa^s yuor M^^rcLH
"f/id A/a Atoaitfoo.^ S> C-M /Dtf '^niAi.
iT) -r^cT CP-^ y/? Sd> /^r Af^ Aox?,£&
c
H /^riou/iod /D/^AIKS ^/^srcT l/c£t\jr ^
* Date.ja^lii^O Jurisdiction QQ^fkVviri
Prepared byi
VALUATION AND PLAN CHECK FEE
• Bldg. Dept.
• Esgil
PLAN CHECK NO. 9Q-\91&>
BUILDING ADDRESS d^Tl^ LolCcr A-\ie
APPLICANT/CONTACT fi7fhgtNrc( UQTICVI PHONE NO. 4^gS->Sl91
BUILDING OCCUPANCY £> '2- DESIGNER PHONE
TYPE OF CONSTRUCTION- Kt^K) CONTRACTOR PHONE
BUILDING PORTION BUILDING AREA VALUATION
MULTIPLIER
VALUE
TiX. • Gtti(^t^
•
•
Air Conditionine
- Commercial -(a
Residential @
Res. or Comm.
Fire Stjrinklers @
Total Value 17 o,
Building Permit Fee $_
Plan Check Fee $
COM H E N TS:
SHEET (OF 1
12/87
BUILDING PLANCHECK
, ENGINEERING CHECKLIST
DATE: n DF=r 90 Ll jTEM COMPLETE
PLANCHECK N0.90~l^i6 ^ ITEM INCOMPLETE
NEEDS YOUR ACTION
ZSlS LOKER. A\IE ITEM SELECTED
^PNI 209-0-"^ • :.-S
PROJECT ID:
(/)'
S
1 2 3
s N R
T D D
C C C
H H H
E E E
K K
E5 • •
LEGAL REOUIREMENTS
Site Plan
1. Provide a fully dimensioned site plan drawn to scale.
Show: north arrow, property lines, easements, existing and
proposed structures, streets, existing street improvements,
right-of-way width and dimension setbacks.
2. Show on site plan: Finish floor elevations, pad
elevations, elevations of finish grade adjacent to
building, existing topographical lines, existing and
proposed slopes, driveway with percent (%) grade and
drainage patterns.
3. Provide legal description and Assessors Parcel Number.
Discretionary Approval Compliance
4. No Discretionary approvals were reguired.
L] Ll Ll 5^ Project complies with all Engineering Conditions of
Approval for Project No. .
L Q Q Project does not comply with the following Engineering
Conditions of Approval for Project No. \
Conditions complied with by: Date:
Field Review
7. Field review completed. No issues raised.
L n Ll 8^ Field review completed. The following issues or
discrepancies with the site plan were found:
L Q Ll site lacks adequate public improvements
Ll Ll Ll Existing drainage improvements not shown or in
conflict with site plan.
L L Ll c. site is served by overhead power lines.
FRMOOIO.DH REV. 11/27/90
^ ^ Ll D. Grading is required to access site, create pad or
provide for ultimate street improvement.
^ ^ Ll site access visibility problems exist. Provide onsite
turnaround or engineered solution to problem.
• •• F. Other:
Dedication Requirements
9. No dedication required.
L Ll Ll Dedication required. Please have a registered Civil
Engineer or Land Surveyor prepare the appropriate legal
description together with an 8h" x 11" plat map and submit
with a title report and the required processing fee. All
easement documents must be approved and signed by owner(s)
prior to issuance of Building Permit. The description of
the dedication is as follows:
Dedication completed, Date By:.
[zfd
Improvement Requirements
• 11. No public improvements required. SPECIAL NOTE: Damacred or
defective improvements found adjacent to building site must
be repaired to the satisfaction of the City inspector prior
to occupancy.
O OLI Public improvements required. This project requires
construction of public improvements pursuant to Section
18.40 of the City Code. Please have a registered Civil
Engineer prepare appropriate improvement plans and submit
for separate plancheck process through the Engineering
Department. Improvement plans must be approved,
appropriate securities posted and fees paid prior to
issuance of permit. The required improvements are:
Improvement plans signed. Date: by:.
FRMOOIO.DH REV. 11/27/90
13. Improvements are required. Construction of the public
improvements may be deferred in accordance with Section
18.40 of the City Code. Please submit a letter requesting
deferral of the required improvements together with a
recent title report on the property and the appropriate
processing fee so we may prepare the necessary Future
Improvement Agreement. The Future Improvement Agreement
must be signed, notarized and approved by the City prior to
issuance of a Building Permit.
Future Improvement Agreement completed, Date:
By:
Ll D L 13a. Inadequate information available on site plan to make a
determination on grading requirements. Please provide more
detailed proposed and existing elevations and contours.
Include accurate estimates of the grading quantities (cut,
fill, import, export).
[vTi 14. No grading required as determined by the information
provided on the site plan.
L L Ll Grading Permit required. A separate grading plan prepared
by a registered Civil Engineer must be submitted for
separate plan check and approval through the Engineering
Department. NOTE: The Grading Permit must be issued and
grading substantially complete and found acceptable to the
City Inspector prior to issuance of Building Permits.
Grading Inspector sign off. Date: ^by:
Miscellaneous Permits
^-^L L Right-of-Way Permit not required.
Ll Q D 17. Right-of-Way Permit required. A separate Right-of-way
Permit issued by the Engineering Department is required for
the following:
L L 18. Sewer Permit is not required.
Ll Q D 19. Sewer Permit is required. A sewer Permit is required
concurrent with Building Permit issuance. The fee required
is noted below in the fees section.
L Ll L] 20. Industrial Waste Permit is not required.
FRMOOIO.DH REV. 11/27/90
21. Industrial Waste Permit is required. Applicant must
complete Industrial Waste Permit Application Form and
submit for City approval prior to issuance of a Building
Permits. Permits must be issued prior to occupancy.
Industrial Waster Permit accepted -
Date: /^Z-^-Z-S/^^ Bv: C.^ eAOQff-~^^x_0.
Fees Required
• NJ^A 27. Park-in-Lieu Fee
Quadrant: Fee per Unit:
Total Fees:
23. Traffic Impact Fee
Fee Per Unit: Total Fee:
• M/A 24. Bridge and Thorough fare Fee
Fee Per Unit: Total Fee:
25. Public Facilities Fee required.
• NJM 26. Facilities Management Fee Zone: Fee:
• ^'//^ 27. Sewer Fees Permit No. EDU's • ^'//^
Fee:
28. Sewer Lateral Required:
Fee:
• 29. REMARKS:
ENGINEERING AUTHORIZATION TO ISSUE PERMIT
BY: ^-LS<^ ^ DATE: /-^^^ I
FEES P/qiD POR Il,9^qp7^ opnCE VAJITH PERM/r
THIS PB2M/r COMOTUCT? iCyO^ FT^OFPiCe,
FRMOOIO.DH REV. 11/27/90
o a
.- ^ (Ni
o ^ u
Q4G
PLANNING CHECKUCT
Plan Check No. ?0- /f/^ Address Z97S' Lgw^r .
Phone 438-1161 Planner D a^'itL
APN: 209-OKI" of
(Name)
Type of Project and Use
Zone fh
7S
Facilities Management Zone ^
Legend
Item Complete
Item Incomplete - Needs your action
1, 2, 3 Number in circle indicates plancheck number where deficiency was
identified
Environmental Review Required: YES NO TYPE
DATE OF COMPLETION:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval
• Discretionary Action Required: YES NO J_ TVTE
DATE: APPROVAL/RESO. NO.
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval
• Coastal: YES NO DATE OF APPROVAL:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval
• Landscape Plan Required: YES NO
See attached submittal requirements for landscape plans
C/C/G
Site Plan:
Zoning:
• • • W
3.
4.
3.
4.
Provide a fully dimensioned site plan drawn to scale. Show: Nonh
arrow, property lines, easements, existing and proposed structures,
streets, existing street improvements, right-of-way width and
dimensioned setbacks.
Show on Site Plan: Finish floor elevations, elevations of finish grade
adjacent to building, existing topographical lines, existing and proposed
slopes and driveway.
Provide legal description of property.
Provide assessor's parcel number.
Setbacks:
Front:
Int. Side:
Street Side:
Rear:
Lot coverage:
Height:
Parking:
^•i^^dditional Comments '^^^
Required
Required
Required
Required
Required
Required
Spaces Required
Guest Spaces Required
Shown-
Shown
Shown
Shown
Shown
Shown
Shown
Shown
OK TO ISSUE DATE /<^/^ fjfo
c: Data Entiy PLNCK.FRM
2560 OBION yVAY
CARLSBAD, OA'92008
TELEPHONE
(619) 931-2121
Citp of €axlsihab
FIRE DEPARTMENT
PLAN CHECK REPORT yJ"
A..
PAGE 1 OF _L
APPROVED
DISAPPROVED
PUAN CHECK#
PROJECT LA COSTA t^<0&orT£. ADDRESS Z ^ 7 5~ Lo Krzi? O e-
ARCHITECT \^Lf\KxT CooK. ADDRESS grAi^LSB/Ai:^
OWNER T^C A Ctj'^iSl C/->l P. ADDRESS S/Vv.i Olt=(^cD
OCCUPANCY CONST, '^v' A/ TOTAL 80. FT. i4 2.
^SPRINKLERED ^TENANT IMP.
. PHONE
_ PHONE
STORIES 'Ti<JO
APPROVAL OF PLANS IS PREDICATED ON CONFORMING
TO THE FOLLOWING CONDITIONS AND/OR MAKING
THE FOLLOWING CORRECTIONS:
^1.
2.
3.
^4.
5.
^6.
^7.
9.
J:2^io.
11.
25^13.
NLl4.
PLANS, SPECIFICATIONS, AND PERMITS
Provide one copy of: floor plan(s); site plan;^eets) T/ —/ j T]-3> S<3F -TTE/n r3tr/ o<-^'
Provide two site plans showing the location of all existing fire hydrants within 200 feet of the project.
Provide specifications for the foilowing:
Permits are required for the installation of all fire protection systemscgprihkler^stand pipes, dry chemical, halon,
COa, alarms, hydrants). Plan must be approved by the fire department prior Toinstallation.
The business owner sha^i complete a building information letter and return it to the fire department.
FIRE PROTECTION SYSTEMS AND EQUIPMENT
The following fire protection systems are required
^Automatic fire sprinklers (Design Criteria: A5> ^ K)
• Dry Chemical, Halon, CO2 (Location:
• Stand Pipes (Type:
3>
-) • Fire Alarm (Type/Location:
Fire Extinguisher Requirements:
"^.One 2A rated ABC extinguisher for each Cc-f Y^O sq. ft. or portion thereof with a travel distance to the nearest
extinguisher not to exceed 75 feet of travel.
• An extinguisher with a minimum rating of to be located:
• Other:
8. Additional fire hydrant(s) shall be provided.
EXITS
Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort.
A sign stating, " This door to remain unlocked during business hours" shaii be placed above the main exit and-
doors
EXIT signs (6" x V*" letters) shall be placed over all required exiits and directional signs located as necessary to
cleariy indicate the location of exit doors.
GENERAL
Storage, dispensing or use of any flammable or combustible liquids, flamrnabie liquids, flammable gases and
hazardous chemicals shall comply with Uniform Fire Code. S???- XTfc: 1 v ^ t M P3<= L ocJ
Building(s) not approved for high plied combustible stock. Storage in closely packed piles shall not exceed 15 feet
in height, 12 feet on pallets or In racks and 6 feet for tires, plastics and some flammable liquids, if high stock pil-
ing Is to be done, comply with Uniform Fire Code, Article 81.
Additionai Requirements. . .
D ?K^/ H J / ht^ h^- \J I Seti S b\tEEn S To dCAr^' i F V/ C L. PA. ? c K / ^. L ASS
.15. Comply with regulations on attached sheet(s).
Plan Examiner. Date-
Report mailed to architect . Met with .Attach to Plans
#wV €itp of Carliefbab 2560 ORION C —^ DAZ-cr^ir
CARLSBAD, CA 92008 ^/^^ DEP/^flTMEA/T ' °
TELEPHONE
(619) 931-2121
PLAN CHECK REPORT
APPROVED
DISAPPR^OV^
PLAN CHECK*
PROJECT Z-A l^''(j<CTJ^ ^^-^oOoCT S. ^ ADDRESS 7 'P, 7 ?r Lr^ i<f) ) ^
ARCHITECT A-.fT ^.-^.- -^K ADDRESS C^ArA ^.RAA PHONE H 3)P. A / O/
OWNER Ti=-r--h/ .i^//T^/»V„iA~ /^/-.A?/-^ ADDRESS S'A^J hrPtn PHONE H23LS—ILLJ:
OCCUPANCY _i^t^J_H2 CONST. V /\/ TOTAL SQ.FT. STORIES IZl4j_d
xg^SPRINKLERED'slTENANTIMP.
APPROVAL OF PLANS IS PREDICATED ON CONFORMING
TO THE FOLLOWING CONDITIONS AND/OR MAKING
THE FOLLOWING CORRECTIONS:
PLANS, SPECIFICATIONS, AND PERMITS
1. Provide one copy of: floor pian(s); site plan; sheets \
2. Provide two site plans showing the location of ali existing fire hydrants within 200 feet of the project.
3. Provide specifications for the following:
i. 4. Permits are required for the installation of ail fire protection systems^^iTrTklersj,stand pipes, dry chemical, halon,
CO2, alarms, hydrants). Plan must be approved by the fire departmenfprionoinstailatlon.
5. The business owner shall compiete a building Information letter and return It to the fire department.
FIRE PROTECTION SYSTEMS AND EQUIPMENT
>/ 6. The foliowing fire protection systems are required:
' ^ Automatic fire sprinklers (Design Criteria: /] S p^l? FpA y '
• Dry Chemical, Halon, CO2 (Location: )
• Stand Pipes (Type: . )
• Fire Alarm (Type/Location: )
7 Fire Extinguisher Requirements:
- >O0ne 2A rated ABC extinguisher for each (nOoQ sq. ft. or portion thereof with a travel distance to the nearest
"^l-An extinguisher with a minimum rating of c^'Yiiy to be located: ill, pry'^;
n Othftr:
8. Additionai fire hydrant(s) shall be provided
EXITS
9. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort.
10. A sign stating, " This door to remain unlocked during business hours" shall be placed above the main exit and
doors
/^^ 11 EXIT signs (6" x '^" letters) shall be placed over all required exiits and directional signs located as necessary to
clearly indicate the location of exit doors.
/ GENERAL
Storage, dispensing or use of any flammable or combustible liquids, flammable liquids, flammable gases and
hazardous chemicals shall comply with Uniform Fire Code.
13. Building(s) not approved for high plied combustible stock. Storage In closely packed piles shall not exceed 15 feet
In height, 12 feet on pallets or in racks and 6 feet for tires, plastics and some flammable liquids, if high stock pil-
ing Is to be done, comply with Uniform Fire Code, Article 81.
"y!^ 14. Additional Requirements. :
7) 2 Hi^ rrr t > PA'^.ic I ^ SAmAAn/Ai RFlpi^iigrTN LA'^C ^ B
) ^i-K'irAr / L, L HT)'liu ^,hi/^iL &F DiU. I (ifr v? AAA'
i%) P/^r)L'.' /)&.7Ai( /A 1' /)^4y„..^1A " /-t^j/-) Serr..^)/\/i A;..A.^..,r^,T
^.') p^duj^)^ // u H. (Ao > A i. A 77 OA I I / hr nn pf 7 i. ( / r r 7 9. .k o/
^Zj 3c. 1 S.7"/Ay Skr A\ > 0 0(- r/ fA / A- f^t il / / A(f ?^'^^<')3
l<iC r-//1A/ o n IA ^v^-^ Ai -
.15. Comibly'wftl^ r^^uiatior/^ on attacMtfsfi'e4t(s).
Plan Examiner "^'/^^J Date / / ''^/''^C7
Report mailed to architect Metwith i Attach to Plans
CARLSBAD OAKS EAST
LA COSTA PRODUCTS ADDITION
Carlsbad
Climate Zone #7
Chris Air
Title 24 Energy Calculations
Compliance Method: SCM 3.1
December 7, 1990
Haynal and Company
2171 India Street, Suite A
San Diego, CA 92101
(619) 295-9225
Contractor's License #467907
Certifioate. of Compliance (Part 1 of 2) Performance Requirements CF-IB
. . For in?orceinent Agency Use SnTy Project Title : CARLSBAD OAKS: LA COSTA PRODUCTS ADDITION
Date of certificate : 12-07-1990 Building Permit Number
Architect/Engineer : CHRIS AIR Plan Checked By Date
Project Location : 2875 LOKER AVENUE, EAST Field Checked By Date
Project City/Town : CARLSBAD Approved By Date
Doc. Author : Haynal and Conpany (619) 743-5408 / 295-9225
PRINCIPAL DESIGNER.. Proposed building .vilI be in substantial ENERGY ANALYST. . The energy performance,analysis sunmarized below comptiance with the CfliifproTa Buiicting irtergy Efficiencv was performeaj using an, ap6r&ve<| CEC.calculation method, with CEC Standards provided it .i.s, bunt according to tne plans and approved fixed and restricted engineering inputs for the applicable specifications, and provided future improveffierits are.completed zone ,9nd occgpapckv,type, .and using an appropriate cepre$entation of according to the requirements indicQted.on this Certificate of building {onihg^dhd physital confTguratTon. All significant energy Compliance. The piaos .aod specifications have been prepared conservation feazureB ararlisted below,or on an attached supplement to include all significant energy ,conservation,.features ly ti ^ '\/ / / reojired for .coippi i ance ,with the Standards. , Bui iding ,areas TS>I .* . * rrr— f^f-t/^^ tnit are .unconditioned and/or not subject to the standards are Signature TTUX»n/A<«4C«vVA n Date I J-j 7/ "O indicated on the plans. II' ' i
Plans Dated Specs Dated Name/Title:' Beth "Brummitt NRE-88-2001
Signature A? ^ At- _ Date /"Z-' "7 ' Company : Haynal and Company
Name/Title |^972>fi/2T^ //- f^iyPHxJl^^ f'^'fth. Address : 2171 India Street, Suite A
Company ' fUQff > tOOK, ffl^ City/State/Zip : San Diego, CA 92101
23KOamlnOYKlaFk^ Suite flP' Telephone: (619) 295-9225
City/state/zip 1 Unconditioned or Multi-tenant shell? NO
^ 2 CEC Occupancy Type PLANS L.R.O.
Telephone f^/Cal. License No. ^/>|^'Z>f 3 UBC Occ. Group/Division PLANS B-2
4 Climate Zone PLANS 7 OWNEg,. Tbe energy conservation, features ^ and ,^ performance _ j. . _. . ........ specifications ind.icated on,this document and,on the plans ,and 5 Conditioned Floor Area PLANS 282 sf specif1 cations ,shatl apply to future alteratioos, unless ^ ., j. . . compliance is demoostrated anew and, .a new..Certific^te pf 6 Unconditioned Floor Area PLANS -- sf Coiicliance ^is subipitted. A copy of this Certificate will be , _ ^ , _ ^ ^ . , retained aod^transmitteg to futur| tenant|.subsequent o}*^'"^ or 7 Budget Table (fr. standards)... 7/88 2-53R
mod??fcati'ons to'^t^i*'Builcling^!'lf t8is certi??caw ?s*Tost?a new 8 All. Energy Budget (WS-1A) WS-1A 146 kBtu/sf yr Certificate may be .required before.a ..permit is, issued for, „ , ,_ , _ . , . alterations. Unconditioned areas are indicated pn the plans arid 9 Calc. Method CEC Code/Date SCM 3.1 if these areas are conditioned in the future,, they myst be made . . .. « _ .. to comply with the applicable energy standards then in effect. 10 Multiplier OUTPUT NA
- J / jjJ J 11 Calculated Energy Use OUTPUT 139.7 kBtu/sf yr
Signature /Myfyl^L^ rP^hM/L^^aX^ l'2 • "1 • ENVELOPE REQUIREMENTS
12 Average Roof/Ceiling CF-3 16.73 h f sf/Btu
Name/Title fZ^CA-ilrl^CV?/^ ^^^(^ffi^O^K iFf^j} MCf^ 13 Average Exterior Floor R NA NA h f sf/Btu
14 Average Opaque Wall R CF-3 7.76 h f sf/Btu
Company TKC^ ]Z/uT' 15 Glazing Area in Wall PLANS 43 sf
16 Average SC (Wall Glazing) PLANS 1.0
Address fjp fegy 17 Glazing Area in Roof PLANS NONE sf
18 Average SC (Roof Glazing) PLANS NA
City/State/Zip ^AA/Xl>\K^O '9Z^/3^ LIGHTING REQUIREMENTS
19 Allowed Whole building LPD NA NA watts/sf ENFORCEMENT AGENCY. ^Proposed building.aijd future alterations Mill,coflply with the California Building Energy Efficiency 20 Allowed Common Areas LPD NA NA watts/sf Staijdards provided future alterations.meet tbe .^requirements .,, j , ^ ^ .«„. . indicated on. this Certificate and all applicable inandatory 21 Allowed Tenant Space LPD SCM 1.50 watts/sf measures as long as building occupancy type remains unchanged. j -
3 7 jt~ "22 Package Lighting Reduction NA NA watts/sf
23 Lighting Controls Required? SCM NO (Y/N)
Signature Date MECHANICAL REQUIREMENTS
24 System Type HEAT PUMPS
Name/Title 25 Unit Fan Power 71 .71 watts/sf
26 Rated Cooling Efficiency SCM 8.0 EER (units)
Agency 27 Rated Cooling Capacity SCM 24.0 MBH (units)
28 Rated Heating Efficiency SCM 3.0 COP (units)
Address 29 Rated Heating Capacity SCM NA MBH (units)
30 Economizer cooling SCM NO (Y/N)
City/State/Zip • 31 CF-1X Attached? YES: SCM (Y/N)
Certif j.oate. Qf Compliance (Part 2 of 2) Performance Compliance CF-IB
Project Title : CARLSBAD OAKS: LA COSTA PRODUCTS ADDITION For Enforcement Agency Use Only
Date of Certificate : 12-07-1990 Cond.Flr.Area: 282 sf
Doc. Author: Haynal and Company (619) 743-5408/295-9225 CEC Occ Type: L.R.O. Plan Checked By Date
Note. More than one Part 2 may be submitted, but all must reference the same Part 1. The person responsible for the design
compliance for each major building system acknowledges the following compliance statement by signing the appropriate space below.
Compliance Statement. The proposed building improvements substantially comply with the requirements indicated on the
Certificate of ComptiarKe for this building, dated 12-07-1990. The plans and specifications include the significant energy
conservation features and the compliance documentation is consistent with the plans and specifications.
ENVELOPE Allowed Proposed
1 Average Roof/Ceiling Rt 16.73 16.73 h-F-sf/Btu
2 Average Exterior Floor Rt.. NA NA h-F-sf/Btu Extent of Improvements
3 Average Opaque Wall Rt 7.76 7.76 h-F-sf/Btu
4 Glazing Area in Wall 43 43 sf Plans dated Specs dated
5 Average SC (Wall) 1.0 1.0
6 Glazing Area in Roof NONE NONE sf Signature Date
7 Average SC (Roof) NA NA
Name/Title
Other requirements:
Company
Address
City/State/Zip
Telephone Cal.License No.
Enforcement Agency Date
LIGHTING
8 Basis of Allowed LPD SCM
Allowed Proposed
9 LPD 1.50 watts/sf
10 Package Lighting Reduction watts/sf
11 Adjusted LPD 1.50 1.13 watts/sf
12 Lighting Control Credits? NO (Y/N)
Other requirements:
Extent of Improvements
Specs dated
Name/Title
Company
t>lAUT«CnnK.IM&
Address
Camino VidaRoble, Suite W
»grl8bad.GA92Q{i9
Telephone Cal.License No.
Enforcement Agency Date
MECHANICAL Allowed Proposed
13 Unit Fan Power 71 .71 watts/sf
14 Rated Cooling Efficiency 8.0 8.0 EER (units)
15 Rated Cooling Capacity 24.0 23.0 MBH (units)
16 Rated Heating Efficiency 3.0 3.0 COP (units)
17 Rated Heating Capacity NA 25.4 MBH (units)
18 Economizer cooling? NO NO (Y/N)
19 Simultaneous heat/cool? .. NO NO (Y/N)
Other requirements:
ADDITION: CARRIER 5038YH024 2 TONS CAPACITY
COMPUTER ROOM: PROCESS LOAD: CARRIER 50NQ024 2 TONS CAP.
DUCT AS NEEDED FROM EXISTING HEAT PUMPS BALANCE OF
SPACE.
OR EQUAL
Extent of Improvements
Plans,^ted ^ Specs dated _ , , ^
Signcfture. ^ , Date A
Na../Titl^^^^^^^ ^^^^-^^
City^st^te/Zip^^^^ ^1 f £ C£^ ^7r3iV~
Telephone " ' " ' Cal. License No.
Enforcement Date
CERTIFICATE.QF COMPLIANCE - 31A PERFORMANCE REQUIREMENTS CF-IX
Project Title: LA COSTA PRODUCTS: ADDITION Date: 12-07-1990
Architect/Engineer: CHRIS AIR Time: 10:12
Project Location: 2875 LOKER AVENUE
City/Town: CARLSBAD
Author/Firm: BETH BRUMMITT/ HAYNAL & CO. Telephone # (619) 295-9225
RUNCODE: 12-07-1990-EM PAGE 1 OF 1
Total Zones Zone
1 _ *^
GENERAL
1 Multi-tenant ? N
2 CEC Occ Type OFFICE
3 UBC Occ B-2 OFFICE
4 Climate Zone 7
5 Cond Floor Area (SQFT) . 282
5A Cond Perimeter (FT) .. 50
6 Uncond Floor Area (SQFT) S-ttELL.
7 Budget Table ****************************************
8 All. Eng Budget <See CF-IB, Part I & SCM Budget Summary>
9 Calc. Method CPO-02
10 Multiplier 1.027
11 Calc Eng Use (KBTU/SQFT) 139.75
ENVELOPE REQUIREMENTS
12 Avg Roof R 16.73
13 Avg Ext Floor R 0.00
14 Avg Opaque Wall R 7.76
15 Wall Glaze Area (SQFT). 0
16 Avg SC JWall Glaze) 0.00
16A SideFms/Overhangs ... NO
17 Roof Glaze Area (SQFT).. 0
18 Avg SC (Roof Glaze) .... 0.00
LIGHTING REQUIREMENTS
19 Modeled Zone LPD 1.5
20 Common area LPD N/A
21 Tenant Space LPD * N/A
22 Package Light Reduction. —
23 Light Controls Required? NO
MECHANICAL REQUIREMENTS
24 System Type * HP/AC/EW
25 Unit Fan Power (W/SQFT). 0.71
26 Rated Cooling EER 8.00
27 Rated Cooling Capacity . 24000
28 Rated Heating EFF 3.00
29 Rated Heating Capacity.. g.g.qoo
30 Economizer Cooling NO
*
GF = Gas Furnace, ER = Electric Resistance, HP = Heat Pump, OF = Oil Furnace
AC = Air Conditioning, EC = Evaporative Cooler
GW = Gas Water Heater, EW = Electric Water Heater
**** SCM ENERGY ANALYSIS MODEL VERSION 3.lA ****
*** 2ND GENERATION NONRESIDENTIAL ENERGY STANDARDS ***
******************************************************
DATE: 12-07-1990
TIME: 10:12
PAGE: 1
CLIMATE ZONE
RUN TYPE
TOTAL ZONES
ASHRAE SDT 83
COMPLIANCE
1 RUNCODE: 12-07-1990-EM
*******************************************************************
ANNUAL SITE ENERGY REQUIREMENTS (MBTU'S)
Zone 1
SITE HEATING
SITE COOLING
SITE LIGHTING
SITE RECEPTACLE
SITE FAN
SITE HOT WATER
0.2
3.2
4.7
1.6
3.1
0.1
ANNUAL SOURCE ENERGY USE ESTIMATE (KBTU/SQ.FT.)
Zone 1
SOURCE
SOURCE
SOURCE
SOURCE
SOURCE
SOURCE
HEATING
COOLING
LIGHTING
RECEPTACLE
FAN
HOT WATER
2.5
33.9
50.3
16.8
33.1
1.4
BUILDING
0.2
3.2
4.7
1.6
3.1
0.1
BUILDING
2.5
33.9
50.3
16.8
33.1
1.4
Cond. Area/Perim. = 5.64 Allowed Energy Budget |HC»
BUILDING ANNUAL SOURCE ENERGY USE ESTIMATE IS 139.7 KBTU/SQ.FT.
( NOTE: 1 KWH = 10.239 KBTUS OF SOURCE ENERGY )
ZONE# ZONE FILE
1 LACOSTAD
OCCUPANCY TYPE
OFFICE
WATTS/SF DAYLIGHTING
1.50
Mandatory Measures Checklist MF-1
Projeclliie
Documenlaiion Authmlfim TJito'
For Enloroomonl Agvncy Vr.o Only
" Plan Checked By DaiS"
This Checklist is applkable lo both Rrsi and Second Generation Nonresidential Standards Comptiance
Rolerenoe in
Construction
Documents
Roleionco in
Construction
Documents
Envelope Measures
I I Certified insulation materials per 2-5311(e) /Vv~
I I InsulatMn instaRvd to moot flame spread and smoke
density requirernents of 2-5311 (b) _
I I Urea lormaldehyde loam insulation is installed
per 2-5311(c)
( ) Retrofit insulation specified as per 2-5313
I I Air inlillinlkin is minimizod l>y r.pocificalion ol loslod mnnulacturod doors and windows, propm sealing nnd caulking ol pints nnd oponingR in oxtoiior wnllr.. nnd wontliorslripping ns por Suction 2 531 / . . . .
Lighting System Measures
[I Certified luminaires/ballasls por 2-5314(b) ."T 3
I I Independenicontrolw/enctosed areas per 2-5319(a) . . _
(I Manual switching readily accessible per 2-5319(b) . . . ^
( ) Reduction ol lighting k>ad to al least one half per
2-S319(c). Occupancy sensors or programmaUe timers
meeting GEO criteria may substitute _
[) Separate switching of daytit areas per 2-5319(d). . .
( ) Separate switching ol display and valance lighting ,
in retail and wholesale stores por 2-5319(h) N f\
Automatic control ol display lighting in roUnl
and wholesale stores par 2-53 t9(h) . . . .
I I Tandem winng ol one-and three-lamp luminaires
per2-5319(i)
Dayiighting and Lumen Maintenance
Controls (when applicable)
I ] Uniiormly illumination reduction to one-hall
por 2-5319(8)1 MA
I I Flickof Iroo operation and no premature lamp failure
per 2 5319(8)2 . . .
I I Timo dr>l.-iy5 lo proviinl undos(r.ibki cydinu
pnr2 53l9(n)3 . .
I I Slop swiliJiini} cii>vic(.>s wilh ncpar.ibon btrtwoon
on/oil settings pur 2-5319(n)4 2k
I J Photocell sensors wilh a diffusing cover and l / A
no opaque cover per 2-5319(e)5 NJ f-\
I ) li^anulacturer's mslruclions provided lor installation
and calibration per 2-5319(e)6
I I Proper installation ol controls including sensor location,
certification ol initial calibration and control ol luminaires
only wittiin daylil area per 2-5319(e)8
I) Visible or audiblo maliunclion alarms (wr 2 5319(g) . .
Occupancy Sensing Devices (wiien
applicable)
I ) Visible or audiblo malluncbon alarms per 2 5319(g) . .
t 1 Limits on omissions por exceptions lo 2 5319(e) . . . .
HA.
.JL_
HVAC and Plumbing System Measures
I -T-
Piping insulated as required by 2-5312 . . .
Certifiod HVAC equipment per 2-5314(a) _
Certilied plumbing equipment per 2-5314(a)
Healing and cooling equipment efficiency por 2 5314(b) . _
Pilotless ignition ol gas appliances per 2'53l4(c) . ....
Automatic controls lor oil hours per 2 5315(a)l
Thermostat sot point requirements per 2-5315(a; . . . .
Sequential control ol heating and cooling per 2.53t5(a)3_
Automatic exhaust lan dampers per 2-5316(b)
Thermostat controls lor each zone per 2-53l5(b|
Ventilation provided per 2-5316 and 2-5343 . . .
Ventilation and recirculation air quantity
information provkled per 1403(b)3 . . .
Heaters lor domestic hot water an&or pools per 2-5318 .
EEM Form Revised Soptembor 1988 ol
Energy Budgets Worksheet WS-1A
Proiect Title
Documentation Author/Pirm Date
For Enlorcement Agency Use Only
' PlarTCRecked By t)aie~ '
Summary Data
Second Generation Standards Oooupancy Types
1 Conditioned Fkior Area
2 Total ARowed Energy Use (MMBlu are Btu x 106|
3 Energy Budget (Une 2 x 1000/ Line 1) (kBiu > Btu x 103|
First Qeneratlon Stmdards Oocupancy Types
4 Conditioned Floor Area MA
5 Total Allowed Energy Use |MMBiu are Biu x 106|
6 Energy Budget (Line 5 x 1000/ Une 4) (kBlu » Btu x 103|
sf
Mtl/IBtu/yr
kBtu/yr-sf
sf
MMBtu/yr
kBtu/yr-sf
Second Generation Nonresidential Standards
Occupancy Type
Description/
Fk>or«
Conditioned Cond.
Perimeter
Story lllll Energy
Budget
IkBtu/
(yr-sl)l
Uq htina Adiustmeni Adjusted
Energy Budget (G +J)
Alk>wed
Energy (KxC)/
1(XX)
ll4MBtu/yr
Occupancy Type
Description/
Fk>or«
FkK rArea
Cond.
Perimeter
Story lllll Energy
Budget
IkBtu/
(yr-sl)l
Allowed
LPD
(CF-5)
Pkg. A
LPD Rqt
(H-l)
x38 0
Adjusted
Energy Budget (G +J)
Alk>wed
Energy (KxC)/
1(XX)
ll4MBtu/yr
Occupancy Type
Description/
Fk>or« Per Occupancy Total Por Story
Cond.
Perimeter
Story lllll Energy
Budget
IkBtu/
(yr-sl)l
Allowed
LPD
(CF-5)
Pkg. A
LPD Rqt
(H-l)
x38 0
Adjusted
Energy Budget (G +J)
Alk>wed
Energy (KxC)/
1(XX)
ll4MBtu/yr
Total Total Allowed Energy
First Generation Nonresidential Standards
Occupancy
Type
Description/
Fkior*
Conditioned
Floor
Area
Energy
Budget
(kBtu/yrsf)
Alk>wed
Energy
(0 X D)/1000
Total ToLiI
EEM Form Revised September 1986 Page. ol
SCM - SUMMARY OF ENVELOPE INPUTS (PART 1 OF 2 ) CF-2X
Project Title: LA COSTA PRODUCTS: ADDITION
Date 12-07-1990
Time 10:12 Plan Checked By
Author/Firm: BETH BRUMMITT/ HAYNAL & CO.
RUNCODE: 12-07-1990-EM
Date
Zone
Roof
Type
Roof
Abs.
ROOF
Area
Design
R-value
Area/
R-Value
Ceiling
Height
1 INTERIOR
Totals
0.00 282 16.73 16.85
16.9
8.0
282
Avg. R-val 16.73
OPAQUE EXTERIOR WALLS AND DOORS
Wall
Zone Type
Wall Door
Area Area
Heat
Cap.
Wall
Abs. R-Value At/Rt
1 INTERIOR 400 8 1.15 0.00 7.8 52.57
Totals 400 8
Weighted Average R-Value 7.76
52.57
GLAZING IN ROOF
Horizontal Design Modeled
Zone Type Area U-Value SC
1 NONE 0.0 N/A 0.00
Total 0
EXTERIOR SURFACE AREA = 400
SCM - SUMMARY OF ENVELOPE INPUTS (PART 2 OF 2 ) CF-2X
Project Title: LA COSTA PRODUCTS: ADDITION
Date 12-07-1990
Time 10:12 Plan Checked By
Author/Firm: BETH BRUMMITT/ HAYNAL & CO.
RUNCODE: 12-07-1990-EM
Date
FLOOR AREA/SOFFITS
Floor Design Area/
Zone Type Area R-value R-Value
1 SLAB 282
Totals
Azimuth= 0
282 0
Avg. R-val N/A
GLAZING IN WALLS - Area|Shading Coefficient(sc)
Zone Glazing N|SC E 1 SC s| SC W|SC Total
1 NONE 0|1.00 0|1.00 o| 1.00 0|1.00 0
Totals 0 0 0 0 0
GLAZING CHARACTERISTICS AND WEIGHTED AVERAGES
Zone Total West Total
Avg. Area X Area X Area X
Zone Glazing U-Value SC U-Val. SC SC
1 NONE 1.10 0.00 0 0.00 0.00
Totals 0 0.00 0.00
Building Area-Weighted Averages N/A N/A N/A
TITLE LA ro^7\ FRobac-f"
GROSS FLOOR
GROSS WALL AREA
NORTH EAST
PERIMETER
HEIGHT
iNT^n^l o I?- \o ^^JA<2.Ellou S:(E
SOUTH WEST
GLAZING
NORTH EAST SOUTH WEST
DOORS
NORTH EAST SOUTH WEST
NET WALLS
(north)
(east)
(south)
(west)
SUMMARY
OPAQUE WALL_
GLAZING
DOORS
TOTAL WALL goo
AOROOF 28
SKYLT
NET ROOF 262>
FLOOR S>tAB>
Construction Assembly Compliance Form CF-3
• ' ; For Enloroemeni Aeerwy UM Only
Project Till* I """"
-f^^^Ki/Vi. S CO.
' leumefitatonAuthor/Fnn ^ Dale Ch«*«J^ Data
General Information
1 Assembly Type and Number 6'.NT^l . CE\CI M
2 FrmilnQTyp* '^0OT:>
a FramingS» - .:2y<^
4 FramlngSp«anQ \ C Inches
B lr»ii«lionlnC«<»^y \<^,0 P4i2-ht/Btu
• EBKlhwR-^«lu«ofC«vfty/Fr»nlnfl tS.O^ M2-hrfl9tu
Sketch of Construction Assembly
List of Construction Components
A
DMortpten
t
TeUl R-V»kit w/o Ifcni IS,
InaklsMrluadrftn . 6*2-'
Outside Kfftao* alrMm . (fi7~
1 Totaltiermalredstwioa (RO i . . . . 16. 73
2 lM«kM(t/Une11) , . . OGO
C
Wal
Walaht
D
tfMMo
Vto«t
ffbtlf-h)
I
HC ColCiColD
ToUtfHC
Vlfc^l IO Ll UV^I M^l I r-iC»C5C;i I liw*! jr v-'vyi • if-'nv..4i iv./^ t V-/I I M v-'i
•°T^f<^^-^'jl"iF'N LJTT U-C?T For Enlorcement Agency Use Only
Project Titie ' " I 1
Do^^ntldw^th^im^*'*^^^"'^*^^ ^^^Z^^^^ —Pnr^F^T.iB B^; DiiT"
^S^* General Information
1 Assembly Type and Number /NTggipp^ yp ALC'^
2 Framing Type Jd^lALf
3 Framing Size D i^ M-
4 Framing Spacing I inches
5 Insulation in Cavity Ll F s' hr/Diu
6 Effective R-value ot Cavity/Fiaming "5 -^O F-sl-hr/Biu
Sketch of Construction Assembly
List of Construction Components
A B
Description R-value
2 3.^<2!'vfiRst^v;^ s.'^o
3 M2.^v . "sn:^. £>• tf5
4
5
6 ,
7
8 Total R-Value w/ofilms (^/9.HO
9 Inside surface air film Q • fcg^
10 Outside surlace air film O -(pS
11 Total thermal resistance (Rt) *") ,~1
12 U-value(1/Una 11) Q , I
C
Wall
Weight
(Ib/sf)
<::>>M-i
D
Specific
Heal
(Btu/F-lb)
Total HC
E
HC
Col C X Co! D
(Blu/F-sl)
EEM Form Revised September 1988 Page. ol
Whole Building HVAC Worksheet (HVAC Power Indices) WS-4A
Project Title : LA COSTA PRODUCTS ADDITION For Enforcement Agency Use Only
Date of Certificate : 12-07-1990
Doc. Author: Haynal and Company
(619) 743-5408 / 295-9225
Plan Checked By
Date
Summary Data
1. Conditioned Floor Area 282 ft2
2. Total Fan Watts During Peak Cooling Conditions 0.20 KWatts
3. Fan Wattage Index (Line 2 x 1000 / Line 1) 0.71 W/ft2
4. Total HVAC System Energy During Peak Cooling Conditions .. N/A kBtu/hr
5. Cooling Power Index (Line 4 x 1000 / Line 1) N/A BtuH-ft2
6. Total HVAC System Energy During Peak Heating Conditions .. N/A kBtu/hr
7. Heating Power Index (Line 6 x 1000 / Line 1) N/A BtuH-ft2
Fan Energy
Equipment Brake Horsepower Motor x Drive Efficiency Conversion Number Peak kilowatts
Mark Description Cooling Heating Cooling Heating Factor Fans Cooling Heating
SSHP CARRIER 38YH024 0.16 .6 0.746 1 0.199
Total Kilowatts 0.199
Heating and Cooling Equipment
Equipment
Mark Description
Design
Output
COOLING
Efficiency
Conversion
Factor
SSHP CARRIER 38YH024 23.00 8.0 10.239
Source
kBtu/hr
29.44
HEATING
Design Conversion Source
Output Efficiency Factor kBtu/hr
25.40 3.0 3.000 25.40
Total 29.44 Total 25.40
** BRAKE HORSEPOWER **
BRAKE HORSEPOWER CFM X E.S.P. 800 X 0.50
2.0 < Ton = = 0.16
0.50 < E.S.P. 40% X 6356 40% X 6356
HilTIHO* COOLIMC
Product 38YH...DL (60 Hz)
Data BESTC Apy Deluxe Data BESTC I Heat Pump
Sizes 018 tliru 060
The .38YH...DL Outdoor Sections
of split-system heat pumps are
designed for quiet, reliable heating
during the winter and cooling during
the summer. These heat pump
systems provide economy of
operation through energy
conservation. They recover heat for
indoor comfort from outdoor air
during fhe heating season and, by
automatically reversing the refrigerant
system, remove indoor heat and
excess humidity during the cooling
season. All models have ARI certified
ralings and are UL and CSA listed.
FEATURES/BENEFITS
Compressor — Designed specifically
for heat pump duty, with high energy
efficiency during heating and cooling
operation. Each compressor is
hermetically sealed against
contamination to assure long life and
dependable performance, internally
sprung and externally mounted on
rubber isolators for quiet operation.
Continuous compressor operation is
approved down to — 30 F in the
healing mode, and down to 55 F in
the cooling mode. (See heating and
cooling performance tables.) All
models include a discharge-tube
muffler to prevent sound transmission
of the compressor pulsations to the
indoor or outdoor coils.
Biiilt-In-Reliability Components —
Includes a suction-tube accumulator
that keeps liquid refrigerant from
reaching the compressor; a low-
pressure switch that stops the
compressor if refrigerant charge is
lost; a crankcase heater to keep the
compressor oil warm and free of
refrigerant for maximum lubricity; an
internal compressor relief valve for
high-pressure protection; and
Form 38YHD-2PD
m
;trical data
MIN." MAX MAX FUSEt OR
OPER VOLTS* COMPR FAN WIRE LENGTH HACR TYPE
ppiYH' V/PH Max Min LRA FUA MCA SIZE (Ft.)t CKT BKR AMPS
49.0 ~lT.6 "75.4 12 90 25
ipODL. 61.0 13.7 0.9 18.0 12 75 30
208/230/1 253 187 70.0 17.3 0.9 22.2 12 60 35
BRdOOL 93.0 22.7 1.4 29.8 10 75 50
POOODL c. 110.0 26.3 1.4 34.3 8 100 60
miom. :• 127.0 27.4 1.4 35.7 8 100 60
WMOOL 142.0 32.4 1.4 41.9 8 85 60
58.5 10.4"~ ' F6 14.0 12 120 20
inooDL 79.5 12.8 1.6 17.6 10 160 30
HHOODL 208/230/3 253 187 90.0 16.4 1.6 22.1 10 130 35
ipOODL 208/230/3 253
98.5 20.7 1.6 27.5 8 130 45
MMODL 130.0 20.2 1.4 26.7 8 130 45
I^OODL 39.8 "7.7"" 0.8 10.4 14 220 15
H$jBOODL 460/3 506 414 45.0 8.2 0.8 11.1 14 210 15
WpODL 49.3 10.3 0.8 13.7 12 240 20
IPOODL 65.0 9.1 0.8 12.2 12 240 . 20
Load Amps Heating, Air Conditioning, Refrigeration
eked Rotor Amps
Minimum Circuit Amps
Rated Load Amps
Ue limits of the voltage range at which unit wili operate satisfactorily,
•lay fuse.
1:Length shown is as measured one way along wire path between unit and serv-
ice panel for minimum 2% voltage drop.
NOTE: Control circuit is 24 v on all units and requires external power source.
If other than 60 C copper wire is used, size can be determined from unit ampac-
ity given in above table and applicable table of National Electric Code. Wire size
selected must have current capacity not less than that of copper wire specified
and must not create a voltage drop between service panel and unit in excess of
2% of unit rated voltage. Must use copper wire from disconnect to unit.
pformance data
|l)24^DL
ii03(MK)DL
ARI STANDARD RATINGS*
APPROVED COOLING HEATING
INDOOR Seasonal Efficiency EER Hi-Temp Lo-Temp Seasonal Sound
UNIT Cfm TC With W/O 3-ph Efficiency Rating
TDR.90t TDR.SOt TC COP TC COP HSPF (Bels)
28RD/RN018 650 17,800 9.30 9.00 — 17,900 2.60 11,100 1.92 6.30 7.6
28RD/RN019 650 18,400 9.50 9.20 — 18,400 2.74 11,300 1.98 6.50 7.6
28RH018 650 17,800 9.30 9.00 — 17,900 2.60 11,100 1.92 6.30 7.6
28HQ024 650 18,000 9.40 9.10 — 18,700 2.82 11,300 1.98 6.60 7.6
28RD/RN024 650 18,400 9.50 9.20 — 18,400 2.74 11,300 1.98 6.50 7.6
28RH024 650 18,400 9.50 9.20 — 18,400 2.74 11,300 1.98 6.50 7.6
28RIVI024 650 18,100 9.30 9.00 — 18,400 2.74 11,600 1.98 6.50 7.6
40AQ018 650 17,000 8.60 8.40 — 18,500 2.70 11,300 1.92 6.40 7.6
40DQ018 650 17,800 9.00 8.70 — 18,100 2.56 11,200 1.88 6,20 7.6
40RC018 650 18,200 9.50 9.00 — 18,200 2.78 11,100 2.00 6.60 7.6
40AQ024 650 17,400 9.20 9,00 — 18,800 2.80 11,400 1.98 6.60 7.6
40AO025t 650 18,500 9.50 9.10 — 18,900 2,86 11,500 2.02 6.75 7.6
40DQ024 650 18,100 9.20 8,90 — 18,300 2.72 11,200 1.96 6.50 7.6
40RC024 . 650 18,500 9.40 9.10 — 18,600 2.78 11,400 2.00 6.60 7.6
—^HHQ024—>
TJBRD/RNOS?"
825 23,000 9.40 9.00 — 25,400 300 14,560" 2.12 6.85 7.4 —^HHQ024—>
TJBRD/RNOS?" 850 23,200 9.50 9.00 — 25,400 2.98 14,600 2.12 6.85 7.4
2BRD/RN025 850 23,600 9.50 9,10 — 25,400 2.98 14,600 2.14 6.85 7.4
28RH024 850 23,200 9,50 9.00 — 25,400 2,98 14,600 2.12 6.85 7.4
28RK/I024 850 23,000 9.30 8.90 — 25,400 2,96 14,600 2.12 6.80 7.4
28HQ030 850 23,600 9.50 9.10 — 26,000 3.08 14,700 2.16 7.00 7.4
28RD/RN030 850 24,000 9.60 9,20 — 26,000 3.10 14,800 2.18 7.10 7.4
28RD/RN13001 850 24,000 9.60 9,20 — 26,000 3.10 14,800 2.18 7.10 7.4
28RH030 850 24,000 9.60 9.20 — 26,000 3.10 14,800 2.18 7.10 7.4
28SL030 860 23,400 9.50 9.00 — 25,600 3.02 14,700 2.14 6.95 7.4
40AQ024 850 22,000 900 8.50 25,400 3.00 14.800 2.10 6.85 7.4
40AQ025 . 850 22.600 9.10 8.70 1 -25,800 3.10 14,900 2.16 7.00 7.4
40DO024 850 22.800 9.30 1 890 i 26.200 2.94 14.500 2.10 6.80 7.4
40RC024 850 23.400 940 900 — 25.600 3.02 14.700 2.14 6.95 7.4
40AQ030t 850 23,600 9.50 9.00 — 26,000 3.06 14,700 2.14 7.00 7.4
40AQ031 850 24,000 9.60 9,20 — 26,400 3.20 15,000 2,20 7.20 7.4
40DO030 850 23,600 9.30 8,90 — 26,200 3.04 15,000 2.14 6.95 7.4
40RC030 850 23,600 9.50 9,00 26,000 3.04 14,900 2.14 6.95 7.4
28HQ030 1025 28,400 9.20 B.9Q 8725 30^400 2.86 18,300 2.D6 6,75 7.8
28RD/RN030 1000 29,400 9.50 9.20 8,50 30,600 2.88 18,400 2.'l0 6.85 7.8
28RD/RN13001 1000 29,400 9.50 9.20 8,50 30,600 2.88 18,400 2.10 6.85 7.8
28RH030 1000 29,400 9.50 9.20 8,50 30,600 2.88 18,400 2.10 6,85 7.8
28SL030 1100 28,800 9.20 8.90 8,20 30,600 2.84 18,500 2.08 6.75 7.8
28HQ/VQ036 1100 29,400 9.50 9.10 8,40 31,000 2.96 18,600 2.10 6.95 7.8
28RD/RN03601 1100 30,000 9.50 9.20 8,50 31,200 2.98 18,700 2.12 7.00 7.8
28RD13601 1100 30,000 9.50 9.20 8,50 31,200 2.98 18,700 2.12 7.00 7,8
28RH036 1100 30,000 9.50 9.20 8.50 31,200 2.98 18,700 2.12 7.00 7.8
28RM036 1100 29,000 9.30 9,00 8,30 30.600 2.84 18,500 2.08 6.75 7.8
28SL036 1100 29,800 9.40 9,10 8.40 31,200 2.98 18,700 2.12 7.00 7.8
40AQ030 1100 28,400 9.00 8.70 8,05 30,800 2.86 18,600 2.04 6.75 7.8
40AQ031 1100 30,000 9.50 9.10 8.40 31,200 3.00 18,700 2.10 7.00 7.8
40DQ030 1015 28,800 9.10 8.80 8,15 30,800 2.84 18,600 2.06 6.75 7.8
40RC030 1100 29,200 9.10 8.80 8,15 31,000 2.88 18,800 2.06 6.80 7.8
40AO036t 1100 29,400 9.50 9,00 8,40 31,000 2.92 18,700 2.08 6.90 7.8
• I •,.
eliotes on page 6.
611
Product 28HQIVQ
Data Encased Evaporator Coils Data Direct Expansion
BEST' OUl » 24,000 — 60,000 Btuh
Modular coils for cooling or
heat pump applications
Carrier's modular encased
evaporator coils are ideal for
residentinl or light commercial use.
I hey are compatible finiige-to-flange
wifh (-arrier 4()FS fan and electric
heat sections. They may be used with
Carrier's 58 Series gas- or oil-fired
furnaces, or they may be installed in
existing forced-air systems.
Carrier 28VQ (for upflow/
downflow applications) and 28HQ
(for horizontal applications) provide
maximum refrigerant-to-air heat
transfer in either cooling or heat
pump duty. HQ capacifies — 24,000;
30,000; .36,000; 42,000; 48,000;
and 60,000 nominal Btuh; VQ
capacities — 36,000; 42,000;
48,000; and 60,000 Btuh — provide
additional flexibility.
Carrier 28HQ/VQ coil may be
matched with either Carrier's outdoor
condensing units for straight cooling
duty, or with split system heat pumps
for all-season cooling and heating.
(See outdoor condensing unit or heat
pump literature for Carrier-approved
systems, correct AccuRater piston size
and ARI-certified ratings.) Whatever
the arrangement, modular 28HQ/VQ
coils form their own fully insulated
plenum to effectively .segregate warm
air from cool, helping to eliminate
dripping condensation on enclosed
surface.
1989
Form 28HQ-1PD
165
INSTALLED LIGHTING SUMMARY CP-5
Project Title: LA COSTA PRODUCTS ADDITION For Enforcement Agency Use Only
Doc. Author : Haynal 6 Company 12-07-1990
Plan Checked By Date
Proposed Adjusted LPD
1. Total Installed Lighting Watts 320.0 Watts
2. Control Credit Watts 0.0 Watts
3. Adjusted Watts (Line 1 - Line 2) 320.0 Watts
4. Conditioned Floor Area (from CF-1) 282 ft2
5. Adjusted Lighting Power Density (Line 3/4) 1.13 Watts/ft2
6. Allowed Whole Building LPD (from CF-1, Part 1) 1.50 Watts/ft2
Installed Lighting Summary
Luminaire Referenced in
Reference Construction
Code Documents Luminaire Description
Number of
Luminaires
Watts per
Luminaire
(incl. ballast)
Non-standard value?
Total
Watts
1x4 2-TUBE FLUOR 4.0 80.0 320.0
Building Total 320.0
****** SCM JEtJERGY ANALYSIS MODEL VERSION 3.1A****** DATE: 12-07-1990
*** 2Nb GENERATION NONRESIDENTIAL ENERGY STANDARD *** TIME: 10:10
***************************************************** PAGE: 1
PRIMARY DATA
************
FILE NAME
BUILDING TYPE
BUILDING TITLE
ZONE
AREA (SQ.FT.) *************
LACOSTAD
OFFICE
LA COSTA PRODUCTS: ADDITION
1 OF 1
EXTERIOR WALL 400
WINDOW : NORTH/NORTHEAST 0
: EAST /SOUTHEAST 0
: SOUTH/SOUTHWEST 0
: WEST /NORTHWEST 0
ROOF 282
TOTAL GROUND FLOOR AREA SLAB 282
TOTAL GROUND FLOOR AREA CRAWLS PACE 0
CONDITIONED PERIMETER (LENGTH) 50
ZONE CONDITIONED FLOOR 282
'R'-VALUE (INCLUDING FILM RESISTANCES)
**************************************
WALLS 7.76
WINDOW (INCLUDING AIR FILM RESISTANCES) 91
ROOF 16.73
FLOOR 0
HVAC SYSTEM ***********
HEATING EQUIPMENT TYPE HEAT PUMP
COOLING EQUIPMENT TYPE AIR CONDITIONER
HVAC COOLING CAPACITY (IN BTUS/HOUR) 24000
ECONOMIZER NO
FAN POWER (WATTS/SQ.FT.) 71
AIR CIRCULATION RATE (CFM/SQ.FT.) 2.93
OTHER
*****
AZIMUTH OF NORTHERN BUILDING ORIENTATION 0
SHADING COEFFICIENT 1
HEAT CAPACITY OF EXT. WALL (BTU/F-SQ.FT.) 1.15
LIGHTING LEVEL (WATTS/SQ.FT.) 1.5
CLIMATE ZONE 7
ASHRAE 0.5% OUTDOOR SUMMER DESIGN TEMPERATURE 83
*** DIAGNOSTICS OUTPUT ONLY ***
****** SCM ENERGY ANALYSIS MODEL VERSION 3.1A****** DATE: 12-07-1990
*** 2ND GENERATION NONRESIDENTIAL ENERGY STANDARD *** TIME: 10:10
***************************************************** PAGE: 2
SECONDARY DATA
**************
PHYSICAL PARAMETERS
*******************
DOOR AREA (SQ.FT.) 8
DOOR 'R'-VALUE (INCLUDING FILM RESISTANCES) 2
DOOR ABSORPTIVITY 0
WALL TYPE INTERIOR
WALL GLAZING TYPE NONE
WALL ABSORPTIVITY 0
ROOF ABSORPTIVITY 0
CEILING HEIGHT (FT.) 8
ROOF TYPE INTERIOR
ROOF GLAZING TYPE NONE
SHADING
*******
SHADING COEFFICIENT : NORTH/NORTHEAST 1
: EAST /SOUTHEAST 1
: SOUTH/SOUTHWEST 1
: WEST /NORTHWEST 1
DOES THIS BUILDING HAVE WINDOW OVERHANGS NO
DOES THIS BUILDING HAVE WINDOW SIDE-FINS NO
MECHANICAL AND ELECTRICAL
*************************
RATED HEATING EFFICIENCY 3
RATED COOLING EER 8
WATER HEATER TYPE ELECTRIC
SPECIAL FEATURES
****************
DAYLIGHTING STRATEGIES NO
SOLAR WATER HEATING SYSTEM NO
**** SCM ENERGY ANALYSIS MODEL VERSION 3.lA **** DATE: 12-07-1990
*** 2ND GENERATION NONRESIDENTIAL ENERGY STANDARDS *** TIME: 10:10
****************************************************** PAGE: 3
CLIMATE ZONE
ASHRAE SDT
RUN TYPE
7
8 3
DIAGNOSTIC
BALANCE-POINT TEMPERATURES AND DEGREE-DAYS INPUT
DAY NIGHT
BPTl = 57.94 BPTl = 67.09
BPT2 = 66.23 BPT2 = 75.69
BPT3 = 66.23 BPT3 = 75.69
HDD = 154.15 HDD = 2969.25
CDD = 435.53 ODD = 0.47
ENVELOPE HEAT TRANSFER FACTORS (BTU/HR-F)
OVERALL BUILDING ENVELOPE HEAT TRANSFER RATE (WINTER) 71.7
OVERALL HEAT TRANSFER FACTOR 'K' (WINTER) 116.7
OVERALL BUILDING ENVELOPE HEAT TRANSFER RATE (SUMMER) 71.9
OVERALL HEAT TRANSFER FACTOR 'K' (SUMMER) 113.4
PEAK COOLING EST. = 3344 BTUH - HVAC COOLING CAPACITY = 24000 BTUH
ANNUAL LOADS (MBTU'S)
HEATING 0.7
COOLING 1.8
**** S*CM ENERGY ANALYSIS MODEL VERSION 3. lA ****
*** 2ND GENERATION NONRESIDENTIAL ENERGY STANDARDS ***
******************************************************
DATE: 12-07-1990
TIME: 10:10
PAGE: 4
7 ASHRAE SDT : 83
DIAGNOSTIC
1 RUNCODE: 12-07-1990-DK
*******************************************************************
ANNUAL SITE ENERGY REQUIREMENTS (MBTU'S)
CLIMATE ZONE
RUN TYPE
TOTAL ZONES
Zone
SITE HEATING
SITE COOLING
SITE LIGHTING
SITE RECEPTACLE
SITE FAN
SITE HOT WATER
0.2
3.2
4.7
1.6
3.1
0.1
ANNUAL SOURCE ENERGY USE ESTIMATE (KBTU/SQ.FT.)
Zone 1
SOURCE
SOURCE
SOURCE
SOURCE
SOURCE
SOURCE
HEATING
COOLING
LIGHTING
RECEPTACLE
FAN
HOT WATER
2.5
33.9
50.3
16.8
33.1
1.4
BUILDING
0,
3,
4,
1,
3,
0,
BUILDING
2.5
33.9
50.3
16.8
33.1
1.4
!!! Diagnostic output only - Not to be used for compliance purposes I I I
HOURLY
BUILDING HEAT LOSS RATE DATE: 12-07-1990
PROJECT: LA COSTA PRODUCTS: ADDITION LOCATION: Carlsbad
SYSTEM TYPE: Heat Pump GROSS FLOOR AREA = 282.0
CEILING HEIGHT = 8.0
HAYNAL & COMPANY 425 North Date, Suite A Escondido CA 92025
DESIGN HEAT LOSS
DESIGN TEMPERATURE DIFFERENCE
For All Assemblies Other Than The Three Below 70F - 38F = DT 1 32.OF
For Insulated Floor Over Vented Unheated Space.. Line 1/Line 2 = DT i 2 16.0F
For Uninsulated Floor Over Vented Unheated Space.... Line 2-5F = DT u 3 11.OF
For Slab-on Ground Floors 70F - 49F = DT s 4 21. OF
CONDUCTIVE HEAT LOSS
Assembly Area ft2 or U-Value Hourly
Description Length, ft or F2 DT Heat Loss
Glazing
Wall R-11 400.0 X 0.130 X 32.0 = 1664 Btu/hr
Ceiling R-19 282.0 x 0.060 x 32.0 = 541 Btu/hr
Floor SLAB 50.0 X 1.150 X 21.0 = 1208 Btu/hr
Subtotal = 3413 Btu/hr
INFILTRATION 16 CFM X 1.08 X 32.0 = 553 Btu/hr
OUTDOOR AIR 20 CFM X 3 people X 1.08 X 32.0 = 2074 Btu/hr
Subtotal = 6040 Btu/hr
DUCT HEAT LOSS (0 if there are no ducts) 0.08 x Subtotal = 489 Btu/hr
DESIGN HEAT LOSS = 6528 Btu/hr
Based on ASHRAE
COOLING LOAD CALCULATION
LA COSTA PRODUCTS: ADDITION
August 5 p.m.
Outdoor Temp = 83
Indoor Temp = 78
Cooling DT = 5
1 People
3 (Niimber) x 225 Sensible Factor
3 (Number) x 275 Latent Factor
2 Glass
3 Walls and Partitions
Wall(s)
400 Net Sq. Ft. x
SENSIBLE
LOAD
Btu/hr
675.0
LATENT
LOAD
Btu/hr
825.0
1.0 Factor - CLTD x U 400.0
4 Ceiling
282 Sq. Ft. x 1.0 Factor - CLTD X U
5 Lights
Incandescent
0 (Total Watts in Use) x 3.4
Fluorescent
423 (Total Watts in Use) x 3.4 x 1.2
6 Miscellaneous Heat Sources ()
From Table 4
7 Infiltration
16 CFM X
16 CFM X
5.40 Sensible Factor
4.20 Latent Factor
8 Outdoor Air
20 CFM X 3 people x 1.08 x
20 CFM X 3 people X 0.70 X
5.0 Cool DT =
6.0 Grains =
Total Sensible =
Total Latent =
282.0
1725.8
12000.0
86.4
324.0
15493.2
0.0
67.2
252.0
1144.2
TOTAL LOAD = 16637.4 Btu/hr
Total Load 16637.4 / 12000, = 1.4 Tons
Based on ASHRAE
Tailored HVAC Worksheet (Equipment Loads) WS-4B
Project Title : LA COSTA PRODUCTS: COMPUTER ROOM
Date : 12-07-1990
Doc. Author: Haynal and Company (619) 295-9225 / 743-5408
For Enforcement Agency Use Only
Plan Checked By Date
One of these forms must be completed for each heating and/or cooling primary plant (eg. chiller, air conditioner unit) in the
building. Attach input and output load calculation summaries (hand or computer calculated), and equipment catalog performance
data. This approach does not exempt systems from the general HVAC requirements of Sec. 2-5342(e)1.
GENERAL INFORMATION & DESIGN CONDITICMS -COOLING--HEATING-
1 System name (provide brief descriptor as referenced in plans)
2 Floor area served
3 Outdoor drybulb temperature (per ASHRAE SPCOX)
4 Outdoor wetbulb temperature (per ASHRAE SPCOX)
5 Indoor drybulb temperature (per ASHRAE Standard 55 1981)
6 Indoor relative humidity (per ASHRAE Standard 55 1981)
Heat Pump 189 ft2
83 F
72 F
78 F
50 RH
Heat Pump 189 ft2
38 F
N/A F
70 F
N/A RH
LOAD CALCULATION SUMMARY -COOLING-
Line 26a must be less than or equal to Line 25a. Line 26b must be less than or equal to Line 25b.
If not, reference exception: PROCESS LOAD: 24 HR CONTROL NEEDED. SIZE TO COOL.
-HEATING-Area Design Total Load Sensible Load
ft2 Parameter Value kBtu/h kBtu/h
7 Glass conduction 43 Ave Uval 1.10 Btu/h ft2 F 1514
8 Glass solar gain 43 Ave SC 1.02 1619
9 Wall coTKhjction 135 Ave Uval 0.13 Btu/h ft2 F 135 562
10 Roof conduction 189 Ave Uval 0.05 Btu/h ft2 F 416 302
11 Floor conduction 189 Ave Uval 0.20 Btu/h ft2 F 416
12 People 2 Ave density 95 ft2/person 450
13 Lights 284 U Pwr density W/ft2 1157
14 Misc equipment Pwr density W/ft2 12000
15 Infiltration Cfm/wal area cfm/ft2 38 246
16 VentiIation Cfm/flr area cfm/ft2 216 1382
17 Fan heat Fan static in H20
18 Pump heat Pump head in H20
19 Duct/piping losses 358
20 Other: LATENT 747
21 Other: SLAB 0
22 Other:
23 Total Load (sum lines 7 to 22) 16778 4780
24 Safety/Uarmup Factor (max of 150% cooling, 180% heating) 150 % 180
25 Maximum Adjusted Load (line 23 x line 24/100) a 25166 b 8604
26 Installed Equipment Capacity at Design Corxjitions a 24000 b 24600
FAN POWER DEMAND
(lines 27 through 30 may be left blank for lowrise buildings with less than 4 stories)
27 Fan supply air quantity
28 Fan total pressure drop
29 Adjustment for VAV systems ( = 1.0 for constant volume systems)
30 Adjusted Fan Performance Index (line 27 x line 28 x line 29/1ine 2)
Building average of line 30 must be less than 5.0 cfm-in/ft2
If not, reference exception:
-COOLING-- HEAT ING-
N/A cfm
N/A in.H20
N/A
N/A FPI
N/A cfm
N/A in.H20
N/A
N/A FPI
HOURLY'
BUILDING HEAT LOSS RATE DATE: 12-07-1990
PROJECT: LA COSTA PRODUCTS: COMPUTER ROOM LOCATION: Carlsbad
SYSTEM TYPE: Heat Pump GROSS FLOOR AREA = 189.0
CEILING HEIGHT = 8.5
HAYNAL & COMPANY 425 North Date, Suite A Escondido CA 92025
DESIGN HEAT LOSS
DESIGN TEMPERATURE DIFFERENCE
For All Assemblies Other Than The Three Below 70F - 38F = DT 1 32.OF
For Insulated Floor Over Vented Unheated Space.. Line 1/Line 2 = DT i 2 16.0F
For Uninsulated Floor Over Vented Unheated Space.... Line 2-5F = DT u 3 ll.OF
For Slab-on Ground Floors 70F - 49F = DT s 4 21. OF
CONDUCTIVE HEAT LOSS
Assembly Area ft2 or U-Value Hourly
Description Length, ft or F2 DT Heat Loss
Glazing SINGLE 43.0 x 1.100 x 32.0 = 1514 Btu/hr
Wall R-11 135.0 X 0.130 X 32.0 = 562 Btu/hr
Ceiling R-19 189.0 x 0.050 x 32.0 = 302 Btu/hr
Floor Raised Gyp 189.0 x 0.200 x 11.0 = 416 Btu/hr
Subtotal = 2793 Btu/hr
INFILTRATION 7 CFM X 1.08 X 32.0 = 246 Btu/hr
OUTDOOR AIR 20 CFM X 2 people x 1.08 x 32.0 = 1382 Btu/hr
Subtotal = 4422 Btu/hr
DUCT HEAT LOSS (0 if there are no ducts) 0.08 x Subtotal = 358 Btu/hr
DESIGN HEAT LOSS = 4780 Btu/hr
Based on ASHRAE
COOLING LOAD CALCULATION
LA COSTA PRODUCTS: COMPUTER ROOM
August 5 p.m.
Outdoor Temp = 83
Indoor Temp = 78
Cooling DT = 5
1 People
2 (Number) x 225 Sensible Factor
2 (Number) x 275 Latent Factor
2 Glass
NORTH/SHADED 43 sf X 37.7 Factor
3 Walls and Partitions
Wall(s)
135 Net Sq. Ft. x 1.0 Factor - CLTD X U
SENSIBLE
LOAD
Btu/hr
450.0
1618.9
135.0
LATENT
LOAD
Btu/hr
550.0
4 Ceiling
189 Sq. Ft. X 2.2 Factor - CLTD X U
5 Lights
Incandescent
0 (Total Watts in Use) x 3.4
Fluorescent
284 (Total Watts in Use) x 3.4 x 1.2
6 Miscellaneous Heat Sources ()
From Table 4
7 Infiltration
7 CFM X 5.40 Sensible Factor
7 CFM X 4.20 Latent Factor
8 Outdoor Air
20 CFM X 2 people x
20 CFM X 2 people x
1.08 X 5.0 Cool DT =
0.70 X 6.0 Grains =
Total Sensible =
Total Latent =
415.8
1156.7
12000.0
37.8
216.0
16030.2
0.0
29.4
168.0
747.4
TOTAL LOAD = 16777.6 Btu/hr
Total Load 16777.6 / 12000 = 1.4 Tons
Based on ASHRAE
COMMERCIAL/INDUSTRIAL
APPLICATION FORM FOR INDUSTRIAL WASTE DISCHARGE PERMIT
CITY OF CARLSBAD
APPLICATION: NEW
(CHECK ONE) REVISED X
BY: (^^,X.
BUILDING P.C. NO.; /^/^- -/f/P
APPLICATION NO.: Pno
INDUSTRIAL CLASS:
DATE: /2-^fi•9D
Signature City Representative
APPLICATION FOR INDUSTRIAL WASTE DISCHARGE PERMIT
A. GENERAL: ,< «
SITE A
APPLICANT; Co^H^ FR^OQC^T^ ADDRESS: Z^k^-gtP., H^/^
TYPE OF BUSINESS: /^/^SiTtMt^ ^^^t4r2^ F/^OC;r^ -
APPLICANT'S ADDRESS: S^W.
B. WASTES AND PROCESSING: (Check where applicable)
|~| Domestic Waste Only Industrial Waste
Disqharged to Sewer
Industrial Waste NOT
Discharged to Sewer
GENERAL DESCRIPTION OF WASTE (Chemical and Physical Diaracteristics of
proposed waste); ^j'/ul^J oAoyr^oo ci^ Q^-Y /vWv-.
GENERAL DESCRIPTION OF PROCESS (If Applicable); ^Jle^ prr^^.jrh I.C
QUANTITY: AVERAGE GPD
C. WASTES TO BE DISCHARGED TO SEWER:
WASTE:
(Check One)
TREATED:
UNTREATECrr (Daily) MAXIMUM GPD
(Gallons Per Day)
APPLICANT OR REPRESENTATIVE OF FIRM; 'DlANJ.ftr t- Wiou;yvY2]>
(Print)
T ITLE ;Dvgec-rDR y^r<.r^nnJ C^AJ fWj^ds
SIGNATURE;
DEC 14 '90 is:33 LA COSTFi PRODUCTS INTL. P. 3/5
fa X c St 19- (!S9(^''/^'^S
sT. WILUAM COX. M.O.. PH.O.
oiAiCTon
(Si SI 33S-3337
STEVEN A. ESCOBOZA
ASSISTANT 0<n«CTOR
tei*) 33e-7e33
DEPARTMENT OF HEALTH SERVICES
1700 PACIFIC HIGHWAY. SAN OICCO. CAU^OflNIA ft2101.aA17
HAZARDOUS NATdUiULS QUESTIONtMIRE
New State law. effective Owly 1, ]989» (AB 3205* Chapter 1589.-Statutes 1988) prohibits a City or a County from
issuing Certificate of Occpancy if a business will handle Hazardous Materials unless the business has met or is
meeting the r«<iutrement of a Business Plan for Emergency Response with the San Oiego County Department of Health
Services, Environinental Health Services. H«z«rdous Materials Management Division*
The new law may also prohibit the permitting of a facility handling Acutely Hazardous Materials to be constructed
within 1,000 feet of the outer boundary of a school (K thru 12) unless first meeting the requirements of a Risk
Management and Prevention Program.
To determine whether your business is subject to these new requiretnents, please read and complete this questionnaire.
If the answer to any of the questions below Is jres. applicant must contact the Hazardous Materials Hanagenent
Oivision. 12S5 Imperial Ave.. 3r4 Fl., San Diego. CA 92138>5261. Telephone: (619) 338-2222..
Business Name Contact Person *
^fif^j^-^ti t-'S>H 1 l2J£^
Telephone
Mailing Address City
GAeLS^ArJ>
state Zip
Site Address
Ze>JS LoKBR. Ave-. £.
City
CArie,ut>e>M> CA-
Zip
YES NO
3. E 3 CX3
4. E 3 CXJ
5. E 3 IXI
6. c 3 cxr
7. E 3 E 3
Will your business activity generate Hazardous Waste in any quantity, in any physical form
(solid, liquid, gas)?
Will your business at any one time store, use or handle Hazardous Substances in quantities equal to or
greater than 55 gallons, 500 pounds or 200 cubic feet of compressed gas?
Will your business store, use or handle Carcinogens or Hifflan Reproductive Toxins in any amount?
Will your business store, use or handle Gases with Threshold Limit Values or Time Weighted Averages of
10 parts per million or less?
Will your business use an existing or install an Underground Storage Tank for Hazardous Substances or
Hazardous Wastes?
Will your business store, use or handle Acutely Hazardous Materials?
If your business will be handling Acutely Hazardous Materials, will your business be located within
1.000 feet from the outer boundary of a school?
8. C ] p<3 Is your business listed on
the reverse side of this fonn?
Briefly Describe Nature of the Business Activity or Process:
Printed Name of Owner or Authorized Agent
Signature oOvuneivor Authorized Agent I declare under penalty of perjury that to the
best of my knowledge and belief the responses
made herein are true and correct.
BUILDING INSPECTION DEPT.
PLAN FILE NUMBER
Init.
ForOyar-HMMD use Only
• T 3 Business Plan Completed [ 3 RHPP Completed
Estab. #
H
Distribution:
Original and 1st copy to
DKS.KMMO. 2nd copy to
Applicant. 3rd copy to
City/County PUn Check Reviewed By Oate Reviewed-By Date
Distribution:
Original and 1st copy to
DKS.KMMO. 2nd copy to
Applicant. 3rd copy to
City/County PUn Check
M—314D (O-W)
DEC 19 '90 12:23 LPl COSTR PRODUCTS INTL. P. 2/2
12/19/90 Revised
COMBUSTIBLE FLAMMABLE MATERIALS
QUANTITY
On Hand
ITEM # DESCRIPTION CONDITION/CLASS Gallons
4010000 Frag PA-44629
(Hydroculator Oil)
Combust. Liq,/lII-A 3
4010100 Frag PA-.65961 Combust. Liq./II 50
4010400 Frag Oil X 5044 Combust. Liq./II 3
4010900 Frag PA 65959 Combust. Liq./III-A 2, 5
4011000 Frag Y 7167 Flammable Liq./I-C 12
4011100 Frag Y 7145 Combust. Liq./III-A 2
4011200 Frag Y 7143 Flammable Liq./I-C 3
4011300 Frag Y 7144 Flammable Liq./I-C 2
4011310 Frag N 20730 Combust. Liq./III-B 1. 25
4011400 Frag W-5857-2 Combust, Liq./III-A 1
(closed syj
4011450 Frag W 5420 Flammable Liq./i-c 2
4011510 Frag HBC 10.013/11 Combust. Liq./II 67
40X1800 Frag VF 2136^1 Combust. Liq./III-A 3
4012600 Frag L-1982 N/A 1. 5
4013200 Frag 829892 Combuet.Liq/III-B 2. 25
Isopropanol Flammable Liq./I-B 44
(Closed syj
4010101 Frag 10734/B Combust.Liq/III-A 2. 5
Cone. X 1680 Flammable Liq./I-C 1. 25
Cone. X 1609 Flammable Liq./I-c 1. 25
Cone. X 1647 Flammable Liq./I-C 1
Cone. X 1689 Flammable Liq./I-C 1. 25
DEC 19 '90 12:23 Lfi COSTfi PRODUCTS INTL. P. 3/2
Page 2
COMBUSTIBLE FLAMMABLE B4ATERIALS
ITEM tt DESCRIPTIQN
Ethyl Alcohol
(SDA-40)
CONDITION/CLASS
Flammable Liq./i-C
Ethyl Alcohol Flammable Liq./i-C
(Anhydrous, Denatured)
Men's Cologne
Men's Aftershave
Plamma-ble Liq./I-C
Flammable Liq./I-c
QUANTITY
On Hand
Gallons
4.25
5
0 **
**None on hand right now but will be ordering lat6r-5 gallons)
N/A = Not applicable or no information currently available.
OOSOW/75-76
DEC 14 '90 18:32 LP COSTP PRODUCTS INTL. P. 2/=
SAN DIEGO AIR POLLUTION CONTROL DISTRICT
9150 CHESAPEAKE DRIV^ SAN DIEGO, CAUFORNIA 92123-1095
' (619)694-3307
{ AIR POLLUTION CONTOOL QUESTIONNAIRE [ (]/^^^-/^/g
New State law, effective July 1,1989, (AB 3205, Chapter 1589. Statues 1988) requires that an applicant for a building
permit provide infonnation indicating whether a permit is required from the Air Pollution Control District. This law
further prohibits a City or a Cowty from isstring Certificate of Occupancy unless a business has complied with
provisions of the law that are administered by the Air Pollution Control District.
The new law also imposes additional permitting requirements for a facility within 1,000 feet of the outer boxmdaty of a
school (K. thru 12).
To determine whether your business is subject to these new mqtilrements, please complete this questionnaire.
Business Narne (DBA) ^ Contact Person Phone
Mailing Address , , City State Zip
Street Address of Proposed Facility
YES: NO:
• S
Control
City Zip
1. Win the intended ocotpant install or use any of the equipment listed on the Listing of Air Pollution
District Permit Categories.
(IF ANSWER TO I IS YBS, APPUCAOT MUST COOTACT THK AI<a3 DIRECTLY)
• (3 2. (Answer only If the answer to 1 above is YES) Win the subject facility be located within
1000 feet of the outer boundaiy of a school (K thru 12) as listed in the current Directory of School and
Community College Districts, published by the San Diego County Office of Education and the current
Califomia Private School Directory, compiled in accordance with provisions of Education Code Section
33190.
JBriefly Describe Nature of the intended Business Activity: Indicate Permit Categories:
Narne of Owner or Authorized Agent: ^ Title:
Signature of Owner or Authorized Agent: .
>V( / J^/..----Sate:/?^//4^
.1 iieclare under penalty of
per|uiy that to the best of
my knowledge and belief the
responses made herein are
true and correct
Building Inspection Plan FQe No:
Initials
^ \ - ^ / /
.1 iieclare under penalty of
per|uiy that to the best of
my knowledge and belief the
responses made herein are
true and correct
use only
STATUS:
EXEMPT FROM APCD
PERMIT REQUIREMENTS
Confirming Stamp
APPROVED FOR ISSUANCE
OF BUILDING PERMIT, BUT
NOT FOR OCCUPANCY
Confirming Stamp
APPROVED FOR OCCUPANCY
(APCD Authority to Construct Issued)
Confirming Stamp
JEC 17 '90 17:56 Lft COSTP PRODUCTS INTL. o o.x
P. 2/4
LACOSTA PRODUCTS INTERNATIONAL
(619) 438-2181 Telex 182793 2261 LAS fW-I^AS DRIVE, CARLSBAD, CA 92009
December 17, 1990
TO Whom It May Concern:
La Costa Products international is a distributor of personal
care products and apparel. Due to the growing nature of our
business, we have still maintained the capability to
manufacture small batches of personal care products, including
shampoos, conditioners, lotions, etc.
Personal care products, of course, have no toxic contents.
There are small amounts of inks and solvents used to silk
screen containers for these products. The chemical storage is
limited to economic order quantities and represents the
smallest justifiable amount.
Should you have any further questions, please contact me at
your convenience at (619) 438-2181 (X229)
JA/hn
01
c I
s
I
ii
1^
fr i is^ i 1 % i
f f i
s
I
' V.B UILDING PERMIT
01/21/91 14:46 •;
Page 1 of 1
Job Address: 2875 LOKER AV EAST . Str: .
Permit Type: PLAN CHECK REVISION
Parcel No: 209-083-05-00
Valuation: 0 . \
Construction Type: VN '' > "
Occupancy Group: Class Code:
Description: REMOVE DEMISING WALL
PGR No: PCR91009 ' 'j
• Project No: A900219 6
Development No: . .i
Fl: Ste:
0426 01/21/91 0001 01 ' 02
C-Pf?HT
a^ioi^r
Appl/Ownr : TECHBILT CONSTRUCTION CORP
3 57 5 KENYON STREET
- V- ..tv SAN DIEGO, CA 92110
Status: ISSUED
• • Applied: 01/21/91
•• - Apr/Issue :
Validated By: DC
619 22 3-1163
Fees Required ***
Fees
A(.i justments
Total Fees
110.H ,
1 1 ) 0 0
Fee description
Plan Check Revisi -n Fee
r'ee.: (. oljected & Cz^edits ** *
Tot -11 Ci^'-^ . t 3 :
Ba j.':i>ice I/Ut; ;
Linit;; i-r-.-;j>.it
lio uu
-•
.00;, '
. 0 0 s ,
110.00
Ext fee Data
110.00
FINAL APPfWVAL
INSP. DATE_
CLEARANCE
CITY OF CARLSBAD
2075 Las Palmas Dr.. Carlsbad CA 92009 (619) 438-1161
PERMIT APPLICATION
City of Carlsbad Building Department
2075 Las Palmas Dr., Carlsbad, CA 92009 (6i9) 438-ii6i
L. PERMIT TYPE I
A - •COMMERCIAL QNEW •TENANT IMPROVEMENT
B - GlNOUSTRIAC ntlEW QTENAMT IMPROVEMENT
c - •RESIDENTIAL DAPARTMENT •CONDO •SINGLE FAMILY DWELLING •ADDITION/ALTERATION
• DUPLEX •DEMOLITION •RELOCATION •MOBILE HOME nELECTRICAL npLUMBING
• MECHANICAL •POOL nSPA nRETAINING WALL •sOLAR nOTHER
PROJECT INFORMATION PLAN CHECK NO.
EST. VAL
PLAN CK DEPOSIT
VALID. BY
DATE
Nearest Cross Streets P^^Lfm tt^tfP •
Pi^f^ Building or Suite No.
/^ry^P/mX,
LEGAL DESCRIPTION Lot No. Subdivision Name/Number Unit No. Phase No.
CHECK BELOU IF SUBMITTED:
• 2 Energy Calcs ^2 Structural Calcs ^2 Soils Report •! Addressed Envelope
ASSESSOR'S PARCEL EXISTING USE PROPOSED USE
KSCRlPllONWUORt! /Zg^^J^^j,/^^
BLDG. SO. FTG. ^ > "5
i^^////</^ lA/^^^1
# Of STORIES "Z.
KSCRlPllONWUORt! /Zg^^J^^j,/^^
BLDG. SO. FTG. ^ > "5
i^^////</^ lA/^^^1
# Of STORIES "Z.
77^ A^'A-^ ^^.^^0
3. CONTACT PERSON
ADDRESS 2,3 cAfrvsilfOD Y//?A PijnS'^^
STATE C/^/^ ZIP CODE ^ ^ TELEPHONE ^ S g, \
4. APPLICANT •CONTRACTOR
NAME
• AGENT FOR CONTRACTOR
ADDRESS
• OWNER • AGENT FOR OWNER
CITY STATE ZIP CODE DAY TELEPHONE
5. PROPERTY OWNER
NAME
OWNER
ADDRESS
• LESSEE QTENANT
CITY STATE ZIP CODE DAY TELEPHONE
STATE
STATE LIC. #
ADDRESS
ZIP CODE
LICENSE CLASS
DAY TELEPHONE
CITY BUSINESS LIC. #
SIGNATURE TITLE
DESIGNER NAME
CITY
ADDRESS
ZIP CODE DAY TELEPHONE STATE LIC. #
WORKERS' COMPENSATION
Workers' Compensation Declaration: I hereby affirm that I have a certificate of consent to self-insure issued by the Director of Industrial Relations,
or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the
insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C).
INSURANCE COMPANY POLICY NO. EXPIRATION DATE
Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner
so as to become subject to the Workers' Compensation Laws of California.
SIGNATURE
8. OWNER-BUILDER DECLARATION Owner-Builder Declaration: I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
• I as owner of the property or my employees with wages as their sote compensation, will do the work and the structure is not intended or offered for sale
(Sec. 704*, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon,, and who
does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building
or improvement is sold within one year of completion, the owner-buitder witl have the burden of proving that he did not build or improve for the purpose
of sale.).
• I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 70W, Business and Professions Code:
The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s)
licensed pursuant to the Contractor's License Law).
• I am exempt under Section Business and Professions Code for this reason:
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, inprove, demolish, or repair any structure,
prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the
Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom,
and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not
more than five hundred dollars [$500]).
SIGNATURE DATE
COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY:
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act?
• YES QNO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?
• YES •NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site?
• YES QNO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISS(JED AFTER JULY 1, 1989 UNLESS THE APPLICANT HAS MET OR IS MEETING THE REOUIRENENTS
OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code).
LENDER'S NAME LENDER'S ADDRESS
APPLICANT'S SIGNATURE I certify that I have read the application and state that the above information is correct. I agree to comply with all City ordinances and State laws relating
to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO
AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS IME CITY OF CARISBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS ANO EXPENSES WHICH MAY IN ANY UAY ACCRUE AGAINST SAID
CITY IN CONSEOUENCE OF THE GRANTING OF THIS PERMIT.
Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building
or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended
or abandoned at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code).
Q OWNER Q CONTRACTOR • BY PHONE
WHITETTtte-YetcDW: Applicant PINK: Finance
APPROVED BYt
DATEs
ESGIL CORPORATION
0320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 560-1468
DATE; I / <2.4:/ 5 I • APPLICANT
JURISDICTION: Qar\g>bnLr( "^^^ PLAN CHECKER
• FILE COPY
• DESIGNER
PLAN CHECK NO: 90" 1918:3 SET;ReV.1r QUPS
PROJECT ADDRESS: ^ LoUer AtVe.
PROJECT NAME: t-O^ (lc>S>^C^ P^OcH^ ULcV^"^ ^IgC P\cxm.
•
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
j—I The plans transmitted herewith will substantially comply
L_J with the jurisdiction's building codes when minor deficien-
cies identified are resolved and
checked by building department staff.
•
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
Esgil staff did not advise the applicant contact person that
plan check has been completed.
j j Esgil staff did advise applicant that the plan check has
— been completed. Person contacted:
•
Date contacted: Telephone #_
Q] REMARKS: ;
ESGIL CORPORATION ^0.^^91
• GA DAA DRN QDM
JURISDICTION:
PLAN CHECK NO
PROJECT ADDRESS
TO
dcLvls lD(>lgi Date plans received by plan checker; I j ^"2- j9 |
\ loAh\ Rv, QVI {Ji <L\C UPV\ <A( 9 A -1 9 ^tat?&an ctick comDlete<i: \^2.4i9l Bv; CV^ (A-dC UgV\c\e^vWll
PLAN CORRECTION SHEET
FOREWORD; PLEASE READ
Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform
Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and disabled access. The plan check is based on regulations enforced
by the Building Inspection Department. You may have other corrections based on laws and ordinances
enforced by the Planning Department, Engineering Department or other departments.
The items shown below need clarification, modification or cdiange. All items have to be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 303(c), of
the Uniform Building Code, the approval of the plans does not permit the violation of any state,
county or city law.
PLANS
1. JPlease make all corrections on the original
tracings and submit two new sets of prints,
and any original plan sets that may have been
returned to you by the jurisdiction, to;
ESCLlL Goro
To facilitate checking, please identify, next
to each item, the sheet of the plans upon
which each correction on this sheet has been
made and return this check sheet with the
revised plans.
QPlease indicate here if any changes have
been made to the plans that are not a result
of corrections from this list. If there are
other changes, please briefly describe them
and v^ere they are located on the plans.
Have changes been made to the pl£uis not
resulting from this correction list? Please
check.
Yes No
(T) lA^Via± -vile, ^reviiou^. m^e oj^ -^e axco.^
3
p ^ SSI
^
ncrr^r rla/v^,e. M->\-V\\ UBC. 4€>0-9 Q/V^I-rile attar V>grA
-V-OuD (m -^e Q(\kt\v\^ pixll
Form No. PCS.41390 t\\e (XHtXcl/VeCV^ K)t03S tVe ocHtxcKecl^ K)lo3S letter MEd 3^4
@ S\v3oo "iVie <^e^'d exits 5^o^-t\le pxofosec( vnauuiic4anvi^
asroo^. A- VYIOWV^ of -Vtoo tfxvt-s os^ reg'd. \
SAN DIEGO AREA
ELECTRICAL NEWSLETTER
THE SAN Dieao AREA CHAPTER OF THE INTERNATIONAL CONFERENCE OF BUIUDING OFFICIALS APPROVES THE CONTENT
OF THIS NEWSLETTER AND RECOMMENDS ITS ADOPTION BY THE MEMBERS OF THE CHAPTER.
CHECK WITH THE LOCAL INSPECTION JURISDICTION BEFORE BEGINNING ANY INSTALLATION BASED ON THIS NEWSLETTER.
CODE REFERENCE SUBJECT PUBLISHED
384 SWITCHBOARDS JUNE 90
The testing and listing standards for switchboards recjuire that the
manufacturer identify any equipment intended to be installed in the field.
Equipment intended for field installation must be identified by part or
catalog number on a label in the switchboard. The manufacturer must also
provide any instructions necessary for the proper installation of such
equipment. These requirements specifically include terminal connectors.
Most switchboards are designed to be connected to other sections or equipment
with splice and through bus. Some switchboards also provide a set of factory
installed terminals for tapping a single circuit ahead of the service main.
Very few switchboards are designed for the field installation of terminals on
busses in order to make cable connections. Those designed for this
application will include the required markings and installation instructions.
The following procedures are established to insure that switchboards are
installed in conformance with the testing and listing standards for such
equipment.
1. Plan reviewers will reject plans showing field connections of cable to
busses unless there is documentation that the equipment is suitable for
the field installation of terminals.
2. All new switchboards will be inspected to detennine compliance with the
listing and manufacturers instructions provided with the equipment.
3. All installations of new cables in existing switchboards will be
inspected to determine compliance with the listing and manufacturers
instructions provided with the ecjuipment. In some cases, this will
require changes to existing cable connections.
4. Switchboards not designed and marked for the field installation of
terminals cannot be modified in the field.
SANDIEGOAREA
ELECTRICAL NEWSLETTER
THE SAN DIEGO AREA CHAPTER OF THE INTERNATIONAL CONFERENCE OF BUILDING OFFICIALS APPROVES THE CONTENT
OF THIS NEWSLETTER AND RECOMMENDS ITS ADOPTION BY THE MEMBERS OF THE CHAPTER.
CHECK WITH THE LOCAL INSPECTION JURISDICTION BEFORE BEGINNING ANY INSTALLATION BASED ON THIS NEWSLETTER.
CODE REFERENCE SUBJECT PUBLISHED - REVISED
450-9 " TRANSFORMER VENTILATION DEC 81 - APR 85
Closets and rooms housing transformers shall have provisions to maintain an
ambient temperature which does not exceed the ambient temperature rating on the
transformer. This may be accomplished by natural or mechanical ventilation, by
mechanical cooling, or by other means.
1., Natural ventilation which complies with the provisions of Section 450-45
shall be acceptable.
2. Mechanical ventilation which provides for air movement of 3 cubic feet per
minute/per KVA of transformer rating shall be acceptable.
3. Mechanical cooling which can be demonstrated to maintain an ambient
temperature below that of the transformer rating shall be acceptable.
4. Any other means, including combinations of the above methods, which can be
demonstrated to maintain an ambient temperature below that of the
transformer rating shall be acceptable.
Any ventilation openings from the room into the interior of the building shall
be protected by a damper having a fire rating of not less than one hour.
CODE REFERENCE SUBJECT PUBLISHED
450-21(b) TRANSFORMERS OVER 112-1/2 KVA APR 85
For the purposes of this subsection, a "transformer room of fire resistant
construction" shall mean a room enclosed by not less than one hour rated walls
and floor/ceiling assemblies, with metal or solid wood, non-rated doors with
self-closing devices.
Date I \ Jur isdiction
Prepared byt
o.u. VALUATION AND PLAN CHECK FEE
• Bldg. Dept,
• Esgil
PLAN CHECK NQ. 9(^-l9\fe feV-X
BUILDING ADDRESS 2.2ilS key- A\ie.
APPLICANT/CONTACT V\e.vm fixtl-€,r<;ny\ PHONE NO.
BUILDING OCCUPANCY 6-2>- DESIGNER PHONE
TYPE OF CONSTRUCTION CONTRACTOR PHONE
BUILDING PORTION BUILDING AREA VALUATION
MULTIPLIER
/
Air Conditionine
Commercial @
Residential
Res. or Conun.
Fire Sprinklers @
Total Value
•DuilJliiy PBI III It Fee $_
Plan Check Fee $
COM ME N TS;
\1U
SHEET I OF I
12/87
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO. CA 92123
(619) 560-1468
DATE;
JURISDICTION: Q3.cl$>b(3^c(
PLAN CHECK NO: 90^Q l& SET: fteV.
• JORISD I CTl5fr-\
PROJECT ADDRESS:
PROJECT NAME: (LnsAa P^nAucA^ X r.
LICANT
• DESIGNER
•
•
•
•
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with the jurisdiction's building codes when minor deficien-
cies identified are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
I I The applicant's copy of the check list has been sent to:
Esgil staff did not advise the applicant contact person that
plan check has been completed.
I I Esgil staff did advise applicant that the plan check has
— been completed. Person contacted:
Date contacted:
REMARKS:
Telephone #_
By:[ LL ESGIL CORPORATION y^^jj
•GA DAA DRN QDM
Enclosures:
Datei l^>6?^9i Jurisdiction Qgrlslr^g^C
Prepared byt
VALUATION AND PLAN CHECK FEE
• Bldg. Dept,
O Esgil
PLAN CHECK NO. 90-IS\& ReV.
BUILDING ADDRESS Z2n3 Lpkor Avg.
APPLICANT/CONTACT fiirl^mcl UnT<cV\ PHONE NO. 4&^--5\91
BUILDING OCCUPANCY fe-^ DESIGNER PHONE
TYPE OF CONSTRUCTION \/-/0 CONTRACTOR PHONE
BUILDING PORTION BUILDING AREA VALUATION
MULTIPLIER
•VJ^LIlE ES<=^\L
HrKy \)C8&^
/
Air Conditionine .
Commercial
Residential @
Res. or Comm.
Fire Sprinklers @
Total Value
DuilUliiy Pui'init Fee $_
Plan Check Fee $
C 0 M M E N TSj_
SHEET OF
12/87
ill ISl ill o QC J L r Hliiliil .1 il 1 II