HomeMy WebLinkAbout2875 LOKER AV EAST; ; CB940203; Permit03/07/94 12 Page 1 of Job A<3caress Permit Type Parcel No: Valuation: BUILDING PERMIT : 52 1 : 2875 LOKER AV EAST Suite: : INDUSTRIAL TENANT IMPROVEMENT 209-083-05-00 Lot#: 19,750 Permit No: Project No I Development No; Construction Type: VN Occupancy Group: B-2 Reference*i Description: 790 SF MANUFACTURING TO OFFICE Appl/Ownr : MARSCH, RICHARD 5411 AVENIDA ENCINAS #120 CARLSBAD, CA. 9 2 008 Status! Applied: Apr/Issue: Entered By; 619 438-4123 CB940203 A9400288 ISSUED 02/25/94 03/07/94 MDP *** Fees Required *A* * * * Fees Collected & Credits * * * Fees: 2,41J.OO, Adjustments: AV»00-i .•; ' • i^..', Total Credits: 00 Total Fees: 2,413,00' Total Payments: 135 . 00 Balance Due: 2,278. 00 Fee description - , .,, Units FeoyUnitS^ Ext fee Data X. • Building Permit 207. 00 Plan Check 135 . 00 Strong Motion Fee 4. 00 Enter Number of EDU's - Water Fee 672 . 00 Enter "Y" to Autocaic License Tax > 359 . 00 Y (Lie Tx) C.F.D. 332 . 00 (TIF Fund) 206 . 00 (TIF CFD Fund) 190 . 00 Enter Bridge Fee ^ 264.00 264. 00 * BUILDING TOTAL 2369 . 00 Enter "Y" for Plumbing Issue Fee N Enter "Y" for Electric Issue Fee > 10 . 00 Y Enter."Y" for Remodel > 10 . 00 Y *, ELECTRICAL TOTAL 20. 00 Enter 'Y' for Mechanical Issue Fee> 15 . 00 Y Install Furn/Ducts/Heat Pumps > 1 9.00 9 . 00 * MECHANICAL TOTAL 24. 00 CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 S^E Ji„E R PERMIT 03/07/94 12:54 Page 1 of 1 Job Address: 2875 LOKER AV EAST Suite: Permit Type: SEWER - OFFICE/WAREHOUSE Parcel No: 209-083-05-00 Permit No: SE940024 BIdg PlanCk#: CB940203 Description: 790 SF MANUFACTURING TO OFFICE Permitee: MARSCH, RICHARD 5411 AVENIDA ENCINAS #120 CARLSBAD, CA, 92008 *** Fees Required *** Fees: 516.00. Adjustments: . .00 Total Fees: 516.00 Fee description 619 438-4123 Status Applied Apr/Issue Expired Prepared By Collected & Credits ISSUED 03/04/94 03/07/94 MDP * * * Total Credits: Total Payments: Balance Due: Units Fee/Unit . 00 . 00 516.00 Ext fee Data Enter Office Square Footage > <Enter CREDIT EDUs> > Total EDUs Sewer Fee Enter Sewer EDUs and Benefit Area / Enter "Y" for Lateral Deposit > * SEWER TOTAL 790 . 16 . 44 -.16 . 28 495.00 21 . 00 516.00 G N/A CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 cic I MS-5-5- PERMIT APPUCATION City of Carlsbad Building Department 2075 Las Pains Dr., Carlsbad, CA 92009 (619) 438-1161 1, PJittMlT'lVPE A - U Commercial U New Building U Tenant Improvement B -^tndustrial • New Building [S^enant Improvement C-• Residential • Apartment • Condo • Single Family Dwelling • Addition/Alteration • Duplex • £)emolition • Relocation • Mobile Home • Electrical • Plumbing • Mechanical DPool • Spa • Retaining Wall • Solar •Other 2. PR(MEcriNFOHMA-noN ^ C^JV^ )P|gOPcXT'*b / K rn. Address m 10 -t^ / I, — /7 ". r.43uilding or tiuite No. PLAN CHECK NO. ^ o3 EST. VAL HAN CK DEFOSrr. VALID. BV_ DATE FOR OFFICE U§E Nearest Cross Street jg^^ FUfyg^TB LEGAL DESCRlKilON Lot No. Subdivision Name/Number Unit No. Phase No. -CHECK BELOW 1^' ijUBMrn'lJU: ^ Energy Calcs • 2 Structural Calcs • 2 Soils Report • 1 Addressed Envelope ASSFSSOB'S PARCKT. EXISTING USF. PROPOSFn USE DESCRIPTION OF WORK 3r SQ.FT. UUNTALT PI NAME 0 # OF STORIES I iJM (.It ditrerent trom applicant^ CITY 4: APPUCANT ucuN'rHACim NAMEp^yc WrtK^O ^1A>1>5PC44 CITY Olh^U^^'ei><t<0 STATE fER'lV OWNEP^ ADDRESS STATE ZIP CODE • AGENT FOR CONTHACmU DAY TELEPHONE • OWNER UAUENT FOR OWNER ADDRESS f^ByJW^/X... ^^tC^M/)4^ 5. PRUPER'IV OWNt NAME T^»C4+ iS/l^r* ZIP CODE DAY TELEPHONE ADDRESS CITY 6. OONT NAME STATC ^ ZIP CODE DAY TELEPHONE ^-^/ CITY STATE STATE UC. # ADDRESS ZIP CODE UCENSE CLASS DAY TELEPHONE UtSlGNbK NAMt TZ.t4V*V0<O }^\P^3^C^^^^^^ ^--f// <;:^ATEt=y;^^ ZIP CODE QTY BUSINESS UC. # DAY TELEPHONE ^4-^^/2.3 STATE UC. # <^24o3g CITY 7. WORKEHtftm Workers' Compensation Declaration: 1 hereby attirm that 1 have a certificate ot consent to selt-insure issued by the Director ot Industrial Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C). INSURANCE COMPANY POUCY NO. EXPIRATION DATE (Jertiticate ot Exemption: 1 certity that in the pertormance ot the work tor which this permit is issued, 1 shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of Califomia. DATE SIGNATURE 8. OWNER-BUILDER DKIARATION Owner-Builder Declaration: 1 hereby attirm that 1 am exempt trom the Contractors License Law tor the tollowing reason: • 1, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Ctode: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.). • I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's Ucense Law). • 1 am exempt under Section Business and Professions Code for this reason: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]). SIGNATURE DATE COMPLETE THIS aECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLV: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 2S533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? • YES • NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? • YES • NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? • YES • NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1, 1989 UNLESS THE APPUCANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POUAJTION CONTROl. IHSTMCT. 9. mN!;mm:HON LKNUIWG AUENCV 1 hereby attirm that there is a construction lending agency tor the pertormance ot the work lor which this permit is issued (Sec 3097UJ l^vil Codej. TO LENDER'S NAME APPLICANT CER'llFlCA'nON LENDER'S ADDRESS 1 certity that 1 have read the application and state that the at>ove intormation is correct. 1 agree to comply with all City ordinances and btate laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CHY OF CARLSBAD AGAINST ALL LIABILITIES, JUDO AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY D* CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. Expiration. Every permit issued by the Building OfHcial under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 365 days from the date of such pennit or if the building or work authorized by such pennit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code). APPUCANTS SIGNATURE DATE: 'T-Z^'fj^ WHITE: File YELLOW: y^plicant PINK: Finance DEPT: BUILDING FINAL BUILDING INSPECTION ENGINEERING MHV PLANNING U/M WATER PLAN CHECK*: CB940203 PERMIT*: CB940203 PROJECT NAME: 790 SF MANUFACTURING TO OFFICE DATE: 03/18/94 PERMIT TYPE: ITI ADDRESS: CONTACT PERSON/PHONE*: RS/TRAVIS/931-1130 SEWER DIST: CA WATER DIST: CA INSPECTED BY: INSPECTED BY: INSPECTED BY: DATE INSPECTED: DATE INSPECTED: DATE INSPECTED: APPROVED 7 APPROVED APPROVED DISAPPROVED DISAPPROVED DISAPPROVED COMMENTS: CITY OF CARLSBAD INSPECTION REQUEST PERMIT* CB940203 FOR 03/23/94 DESCRIPTION: 790 SF MANUFACTURING TO OFFICE TYPE: ITI JOB ADDRESS: 2875 APPLICANT: MARSCH, CONTRACTOR: OWNER: LOKER AV RICHARD EAST REMARKS: MH/TRAVIS/931-1130 SPECIAL INSTRUCT: PHONE: PHONE: PHONE: INSPECTOR AREA PD PLANCK* CB940203 OCC GRP B-2 CONSTR. TYPE VN STE: LOT: 619 438-4123 INSPECT TOTAL TIME: —RELATED PERMITS— PERMIT* TYPE WDP02031 WDP AS940011 ASTI SE940024 SWOW STATUS ISSUED ISSUED ISSUED CD LVL DESCRIPTION ACT COMMENTS 19 29 39 49 ST Final Structural PL Final Plxunbing EL Final Electrical ME Final Mechanical ***** INSPECTION HISTORY ***** DATE DESCRIPTION ACT INSP COMMENTS 032194 Final Combo CO TP ND TRANS & SUB INSP/HVAC 031894 Final Combo CA PD CANCELLED BY TRAVIS 031494 Rough Combo AP PD CEILING 031194 Rough Combo CO PD 031094 Interior Lath/Drywall AP PD 030894 Frame/Steel/Bolting/Welding AP PD WALLS 030894 Rough Electric AP PD ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO. CA 92123 (619) 560-1468 JURISDICTION: PLAN CHECK NO: SET: JL PROJECT ADDRESS: PROJECT NAME: • FILE COPY • UPS • DESIGNER • • • • The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified Se-com are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. Q The applicant's copy-of the check list has been sent to: I \ Esgil staff did not advise the applicant contact person that plan check has been completed. ^ Esgil staff did advise applicant that the plan check has been completed. Person contacted; rZ-icHAt-o /^A^C^ /SY A/'fi7~ Telephone #_ Date contacted: REMARKS: CITY 7P i/P-/t.,PY A- /ZjXif=^ -TC/C^^y is A-OT- /^fc<au//g^i:> (T) ^\CUAeJ> f^D/S-dCH i^ilU NMyP C7i« ^ TH^ P ^s7^ By ESGIL CORPORATION •GA ncM DPC Enclosures: tC7C_ ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560-14€8 DATE JURISDICTION: _ PL.AN CHECK NO: PROJECT ADDRESS PROJECT NAME: 3//A SET: 3r ZS75" Lol^-ejz, Ave ^ TT ^-^pURISD I CTITJWN Xjlr-LAN LHLLKLK /•FILE COPY jUPS • DESIGNER • • • • The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified are resolved.and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to: • • Esgil staff did not advise the applicant contact person that plan check has been completed. Esgil staff did advise applicant that the plan check has been completed. Person contacted:^ Date contacted: REMARKS: Telephone # By; f^BJlE f^.^CH^jp Enclosures; ESGIL CORPORATION ^ i^f^S • GA DCM ^PC _Date plajis received by plan checker:. JURISDICTION:. PLAN CHECK NO.: ^H-ZC>Z ^Date plan recheck completed: 3// A'j By: Fl^Te F/S,CH^y^ PROJECT ADDRESS: "2 &7S' Lat^^-C/Z^ Auf 0^ TO: fZ. M A RECHECK PLAN CORRECTION SHEET FOREWORD; PLEASE READ Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. The plan check is based on regulations enforced by the Building Inspection Department. You nay have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The items shorn below need clarification, modification or change. All items have to be satisfied before the plans will be in- conformance with the cited codes and regulations. Per Sec. 303(c), of the Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. PLANS 7 Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: { 2.y To facilitate rechecking, please identify, —next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this check sheet with the revised plans. The following items have not been resolved from previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the still outstanding corrections. Please contact me if you have any questions regarding these items. Please indicate here if any changes have been made to the plains that are not a result of corrections from this list. If there are other changes, please briefly describe them cind where they are located on the plans. Have changes been made to the plans not resulting from this correction list? Please check. Yes No r>OU (SI- Form No. RPCS.41290 Datet Jurisdiction CA^LS $>AD Prepared byt PgTX F/5CH^/^ VALUATION AND PLAN CHECK FEE PLAN CHECK NO. ^V-Z03 BUILDING ADDRESS ?,67S~ Lc>l^£^ Av£- £. APPLICANT/CONTACT BUILDING OCCUPANCY Q BIdg. Dept. p Esgil TYPE OF CONSTRUCTION IIZI SP/^ PHONE NO. DESIGNER PHONE CONTRACTOR PHONE BUILDING PORTION BUILDING AREA VALUATION MULTIPLIER VALUE TT • /^7rD •• Air Conditioning Commercial Residential @ Res. or Comm. Fire Surinklers Total Value Building Permit Fee $ Plan Check Fee $ /5V COM M E N TS: SHEET 12/87 s Citv of Carlsbad Engineering Department DATE: / / BUILDING PLANCHECK CHECKLIST V/^V^ PLANCHECK NO. I /I BUILDING ADDRESS: PROJECT DESCRIPTION: ASSESSOR'S PARCEL NUMBER: 7^f~77^V^ EST. VALUE ) 7 ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instmctions in this report can result in suspension of permit to build. 1st CHECK By:_ Date: 2nd CHECK By:. Date: 3rd CHECK By:. Date: DENIAL Please see the attached report of deficiencies marked with Q Make necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. By:. Date: By:. Date: By:. Date: 8Y: FOR Of FICAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT: •^7 f DATE: ATTACHMENTS ED Dedication Application D Dedication Checklist EH Improvement Application n Improvement Checklist D Future Improvement Agreement D Grading Pemiit Application n Right of Way Permit Application ED Sewer Fee Information Sheet CONTACT PERSON NAME:. ADDRESS:. PHONE: A-4 P:\DOCS\CHKLSTiBP0001 .FRM REV 12/17/93 2075 Las Palmas Dr. • Carlsbad, CA 92009-1576 • (619) 438-1161 • FAX (619) 438-0894 ® ^ BUILDING PLANCHECK CHECKLIST SITE PLAN 1st)A^nd>/ 3rdV D D 1. Provide a fully dimensioned site plan drawn to scale. Show: A. North Arrow D. Property Lines Easements B. Existing & Proposed Structures E. Easements C. Existing Street Improvements F. Right-of-Way Width & Adjacent Streets • 2. Show on site plan: A. Drainage Patterns C. Existing Topography 8. Existing & Proposed Slopes • 3. Show on a section drawing or include a note stating that there is a minimum of 6" difference between the finished floor and the finished grade elevation adjacent to the structure. • 4. Include note: "Surface water to be directed away from the building foundation at a 2% gradient for no less than 5' or 2/3 the distance to the property line (whichever is less)." [Per 1985 UBC 2907(d)5]. On graded sites, the top of any exterior foundation shall extend above the elevation of the street gutter at point of discharge or the inlet of an approved drainage device a minimum of 12 inches plus two percenf (per 1990 UBC 2907(d)5.). O 5. Include on title sheet A. Site address B. Assessor's Parcel Number C. Legal Description For commercial/industrial buildings and tenant improvement projects, include: Total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION P:\DOCS\CHKt81\BP0001 .FRM Page 1 Of 4 REV 12/17/93 BUILDING PLANCHECK CHECKUST DISCRETIONARY APPROVAL COMPLIANCE V 2nd^/ 3rd%^ n Q 6. Project does not comply with the following Engineering Conditions of approval for ' ^ Project No. Conditions were complied with by: Date: DEDICATION REQUIREMENTS n • 7. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ -pursuant to Code Section 18.40.030. Dedication required as follows: Attached please find an application form and submittal checklist for the dedication process. Provide the completed application form and the requirements on the checklist at the time of resubmittal. Dedication completed by Date: IMPROVEMENT REQUIREMENTS • • n 8a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ -pursuant to Code Section 18.40.040. Public improvements required as follows: Please have a registered Civil Engineer prepare appropriate improvement plans and submit them together with the requirements on the attached checklist for a separate plancheck process through the Engineering Department. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of permit. Attached please find an application form and submittal checklist for the public improvements requirements. Provide the completed application form and the requirements on the checklist at the time of resubmlttal. Improvement Plans signed by: Date: P:\DOCS\CHKLS1\BP0001 .FRM Page 2 Of 4 REV 12/17/93 BUILDING PLANCHECK CHECKLIST 1sW 2ndv/ 3rdv/ • • • 8b. Construction of the public improvements may be deferred pursuant to code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $ so we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building Permit. Future public improvements required as follows: Improvement Plans signed by: Date:, • • • 8c. Enclosed please find your Future Improvement Agreement. Please return signed and notarized Agreement to the Engineering Department. Future Improvement Agreement completed by: Date: • 8d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adiacent to building site must be repaired to the satisfaction of the Citv Inspector prior to occupancv. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. DDD 9a. inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). DDD 9b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be Submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by: \ Date: D 9c. No Grading Permit required. BUILDING PLANCHECK CHECKUST P:\0OCS\CHKLST\BP0001 .FRM Page 3 of 4 REV 12/17/93 If MISCELLANEOUS PERMITS l9t>/ 2ndy/ 3rdv' JZ D D 10. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or ' " private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, trees, driveways. A separate Right-of-Way permit issued by the Engineering Department is required for the following: Please complete attached Right-of-Way application form and return to the Engineering Department together with the requirements on the attached Right-of-Way checklist, at the time of resubmittal. •f D D 11. A SEWER PERMIT is required concurrent with the building permit issuance. The fee ' is noted in the fees section on the following page. D D 12. INDUSTRIAL WASTE PERMIT is required. Applicant must complete Industrial Waste Permit Application Form and submit for City approval prior to issuance of a Permit. Industrial waste permit accepted by:A:ZdMi7. Date P:\DOCS\CHKLST\BP0001.FRM Page 4 Of 4 REV 12/17/93 ENGINEERING DEPARTMENT ENGINEERING REVIEW SECTION FEE CALCULATION WORKSHEET ^ Estimate based on unconfirmed information from applicant. U Calculation based on building plancheck plan submittal. Address BIdg. Permit No.^^f "97-7^3 Prepared bv: /J'^^ Date: AMT- Checked by: Date: EDU CALCULATIONS; List types and square footages for all uses. Types of Use: . . ^^f^/r Sq. Ft: 7^0 X^^^ EDU's: AH Total EDU's: ADT CALCULATIONS: List types and square footages for all uses. Types of Use: 04t7!:r^ Sq. Ft: 1^0 "^/o^ ADTs: Total ADTs: PUBLIC FACIUTIES FEE REQUIRED • YES Jl^NO (See BuikJing Department for amount) WITHIN CFD: D YES (no bridge &thoroughfifefee. J0NO reduced Traffic Imeact Fee^ ^ ) reduced Traffic Impact Fee) 1 .PARK-IN-UEU FEE PARK AREA: FEEAJNU: X NO. UNfTS: 2.TRAFFIC IMPACT FEE ADTs: /A X FEE/ADT: 33 y^Z. BRIDGE AND THOROUGHFARE FEE ADTs: X 4. FACILITIES MANAGEMENT FEE EDU's: X jSf 5. SEWER FEE FEE/ADT: ^P. ZONE: FEE/EDU: PERMfT No.5g f7 EDU's: X FEE/EDU: / 7^ 7 BENEFIT AREA: EDU's: / >^ X FEE/EDU: 76 6. SEWER LATERAL ($2,500 DEPOSIT) IS 7. WATER FEE EDU's: ' P-f X FEE/EDU; J2^t?^ TOTAL OF ABOVE FEES*: JjgTg^Jjjj^gjgylgjjgryllj^^ 3^ 2^/ 717 P- DOCS\MISFOBMS\BP0001 FRM REV M<'23< M 77^J^i7^iL0jjido^/^''y^ ^ / y^;z ^ 7?w f /?<,ujr^ ^ CA^97YZ^ " * ^ ^^pi/^jl/^ ^e^7i:^*/^^4fini^^/7i (^Sf77¥3^ 7i't>i>/^/66^D^,^}A7 175 TV/ £1>7^ j75mj^^ •?/-7'7 *^ " * 9r<}07x. e^,(Mtis^^^a»-.(p = /7f-tf City of Carlsbad 94045 Fire Department Bureau of Prevention Plan Review: Requirements Category: Building Plan Check Date of Report: Tuesday, March 1,1994 Reviewed bv: C- &(KJtck— Contact Name Richard Marsch Address 6351 Corte Del Abeto #113 City, State Carlsbad CA 92009 BIdg. Dept. No. 94-203 Planning No. Job Name La Costa Products Job Address 2875 Loker Ste. or BIdg. No. Av_ KI Approved - The item you have submitted for review has been approved. The approval is based on plans; information and/or specifications provided in your submittal; therefore any changes to these items after this date, Including field modifica- tions, must be reviewed by this office to Insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. • Disapproved - Please see the attached report of deficiencies. Please make con-ections to plans or specifications necessary to indicate compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. For Fire Department Use Only Review 1st 2nd 3rd Other Agency ID CFD J0b# 94045 Fi!e# 2560 Orion Way Carlsbad, California 92008 (619) 931-2121 TITLE 24 REPORT FOR: La Costa Products Addition 2 875 Loker Avenue East Carlsbad, CA PROJECT DESIGNER: White Construction, Inc. 6351 Corte Del Abeto, Suite AlOO Carlsbad, CA 92009 (619)931-1130 REPORT PREPARED BY: Steve Balderrama Haynal & Co., Inc. 425 West Fifth Street v Escondido, CA 92025 :619) 743-5408 Job Number: Date: 2/23/1994 The COMPLY 24 computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential Building Energy Efficiency Standards. This program developed by Gabel Dodd Associates (510) 428-0803. Table Of Contents for Title 24 Report Cover Page 1 Table of Contents 2 Form ENV-1 Envelope Certificate of Compliance 3 Form PERF-1 Building Energy Performance Summary 5 Form ENV-2 Envelope Summary 6 Form ENV-3 Construction Assemblies 9 Form LTG-1 Lighting Certificate of Compliance 11 Form LTG-2 Lighting Compliance Summary 13 Form MECH-1 Mechanical Certificate of Compliance 14 Form MECH-2 Mechanical Summary 17 Form MECH-3 Mechanical Equipment Summary 18 Form MECH-4 Mechanical Ventilation 19 HVAC Zone & Space Loads Summary 20 CERTIFICATE OF COMPLIANCE (part 1 of 2) ENV-1 page 3 of 21 Date: 2/23/1994 Project Name: La Costa Products Addition Address: 2875 Loker Avenue East Carlsbad, CA Envelope Designer: White Construction, Inc. Documentation: Haynal & Co., •'•^'-^ Building Permit No Checked by / Date COMPLY 24 User 2875 GENERAL INFORMATION Date of Plans: Building Conditioned Floor Area: 790 sf Building Type: Nonresidential Climate Zone: 7 Phase of Construction: 0 New Construction p^ddition 0 Alteration Method of Envelope Compliance: Performance - COMPLY 24 v 4.11 STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Part 6, Chapter 1 and Title 20, Chapter 2, Subchapter 4, Article 1 of the California Code of Regula- tions. This certificate applies only to building envelope requirements. The Principal Envelope Designer hereby certifies that the proposed build- ing design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with a:ny other calculations submitted with this permit application. The proposed building has been designed to meet the envelope requirements contained in sections 110, 116 through 118, and 143 or 149 of Title 24, Part 6, Chapter 1. Please check one: 0 I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a civil engineer or architect. 0 I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing docu- ments for work that I have contracted to perform. O I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section of the Code to sign this document as the person responsible for its preparation; and for the following reason: . PRINCIPAL ENVELOPE DESIGNER White Construction, Inc. (619)931-1130 (Signature) (Lie. #) (Date) ENVELOPE MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures: CERTIFICATE OF COMPLIANCE (part 2 of 2) Project Name: La Costa Products Addition Documentation: • Haynal & Co., Inc. ENV-1 page 4 of 21 Date: 2/23/1994 COMPLY 24 User 2875 OPAQUE SURFACES Assembly Name Const Type Location/Comments Note to Field R-11 Wall (W.11.2x4.16) Wood _Exterior Walls R-11 Metal Stud Wall Metal _Demising Walls^ FENESTRATION Frame Orient Panes Type Exterior Shade OH Glazing Type N Single Reflective Left (E) Metal None PERFORMANCE COMPLIANCE SUMMARY Project Name: La Costa Products Addition Documentation: Haynal & Co., Inc. PERF-1 page 5 of 21 Date: 2/23/1994 COMPLY 24 User 2875 ANNUAL SOURCE ENERGY USE (KBtu/sqft-yr) Energy Component Space Heating Space Cooling HVAC Fans & Pumps Domestic Hot Water Lighting Receptacle Process TOTALS Calc: DOE-24 (COMPLIANCE) Standard Design Proposed Design Compliance Margin 5.58 5.85 -0.27 21.72 19.86 1.86 14.39 12.95 1.44 2 .46 2 .44 0.01 47.28 47.81 -0 .53 25.48 25.48 0.00 0.00 0 .00 0.00 116.91 114.39 2.52 *** BUILDING COMPLIES *** OPTIONAL CAPABILITES AND SPECIAL COMPLIANCE INFORMATION PERFORMANCE ENVELOPE SUMMARY Part 1 of 3 Project Name: La Costa Products Addition Documentation: Haynal & Co., Inc. ENV-2 page 6 of 21 Date: 2/23/1994 COMPLY 24 User 2875 GENERAL INFORMATION BY SPACE Space Name Office Addition Occupancy Office Fir Floor Display No Area Volume Perim. 790 7110 PERFORMANCE ENVELOPE SUMMARY Part 2 of 3 ENV-2 page 7 of 21 Project Name: La Costa Products Addition Documentation: Haynal & Co., Inc. Date: 2/23/1994 COMPLY 24 User 2875 OPAQUE SURFACES Act Solar Type Area U-Val Azm Tilt Gains Form 3 Reference Location/Comments Wall 158 0.098 90 90 Yes R-11 Wall (W.11.2x4.16) Office Addition Wall 480 0.190 Int 90 No R-11 Metal Stud Wall Office Addition Sib 790 0.000 0 180 No Covered Slab Office Addition PERFORMANCE ENVELOPE SUMMARY Part 3 of 3 ENV-2 page 8 of 21 Project Name: La Costa Products Addition Date: 2/23/1994 Documentation : Haynal & Co., Inc. COMPLY 24 User 2875 FENESTRATION SURFACES SC Act Glass # Type Area Frame Div U-Val Azm Tilt Only Location/Comments 1 Wdw Left (E) 132.0 Metal No 1.10 90 90 0.55 Office Addition OVERHANGS/SIDE FINS --Window-- Overhang Left Fin Right Fin-- # Type Ht Wd Len Ht LExt RExt Dist Len Ht Dist Len Ht NONE PROPOSED CONSTRUCTION ASSEMBLY Project Name: La Costa Products Addition Documentation: Haynal & Co., Inc. ENV-3 page 9 of 21 Date: 2/23/1994 COMPLY 24 User 2875 COMPONENT DESCRIPTION Sketch of Construction Assembly ASSEMBLY U-VALUE Construction Components Assembly Name: R-11 Wall (W.11.2x4.16) Assembly Type: Wall Assembly Tilt: 90 deg (Vertical) Framing Material: Wood Framing Spacing: " O.C. Framing Percent: 15.0 % Fr 70 , Wood Shingles Th R-Value (in) Cavity Frame 0.17 0.17 0.875 0.17 0.17 0.010 0.06 0.06 3 .500 11.00 3.46 0.500 0.45 0.45 Outside Air Film 1. Stucco 2. Membrane, Vapor-Permeable Felt 3. Insulation, Mineral Fiber, R-11 4. Gypsum or Plaster Board 5. 6. 7. 8. 9. Inside Air Film 0.68 12.53 0.68 5.00 Unadjusted R-Values ADJUSTMENT FOR FRAMING (1 /12.53) X (0.85) + (1 / 5.00) x (0.15) 0.098 TOTAL U-VALUE = 0.098 TOTAL R-VALUE = 10.22 Weight: Heat Capacity: 12.3 Ib/sqft 2 . 87 PROPOSED CONSTRUCTION ASSEMBLY Project Name: La Costa Products Addition Documentation: Haynal & Co., Inc. ENV-3 page 10 of 21 Date: 2/23/1994 COMPLY 24 User 2875 COMPONENT DESCRIPTION Sketch of Construction Assembly ASSEMBLY U-VALUE Construction Components Assembly Name: R-11 Metal Stud Wall Assembly Type: Wall Assembly Tilt: 90 deg (Vertical) Framing Material: Metal Framing Spacing: " O.C. Framing Percent: 15.0 % Absorptivity: 0.70 Roughness: Stucco, Wood Shingles Th R-Value Fr (in) Cavity Frame Outside Air Film 1. Gypsum or Plaster Board 0 .500 0 0 .17 .45 0 0 .17 .45 3. Insulation, Mineral Fiber, 4. Gypsum or Plaster Board 5. 6. "7 R-11 * 3 0 .500 .500 11 0 .00 .45 11 0 .00 .45 / . 8. 9 . Inside Air Film 0 .68 0 .68 Unadjusted R-Values 12 .75 0 .00 TOTAL U-VALUE = 0.190 TOTAL R-VALUE = 5.27 Weight: Heat Capacity: 4.3 Ib/sqft 1.11 CERTIFICATE OF COMPLIANCE (part 1 of 2) LTG-1 page 11 of 21 Date: 2/23/1994 Project Name: La Costa Products Addition Address: 2875 Loker Avenue East Carlsbad, CA Lighting Designer: Documentation: Haynal & Co., ^"^^^^^^^^^^^^^sjllfi-^i^^ Building Permit No Checked by / Date COMPLY 24 User 2875 GENERAL INFORMATION Date of Plans: ^ Building Conditioned Floor Area: 790 sf Building Type: Nonresidential ^ Climate Zone: 7 Phase of Construction: 0 New Construction (a Addition 0 Alteration Method of Lighting Compliance: Performance - COMPLY 24 v 4.11 STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Part 6, Chapter 1 and Title 20, Chapter 2, Subchapter 4, Article 1 of the California Code of Regula- tions. This certificate applies only to building lighting requirements. The Principal Lighting Designer hereby certifies that the proposed build- ing design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the lighting requirements contained in sections 110, 119, 130 through 132 and 146 or 149. Please check one: 0 I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a civil engineer electrical engineer or architect. 0 I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing docu- ments for work that I have contracted to perform. 0 I affinn that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section of the Code to sign this document as the person responsible for its preparation; and for the following reason: . PRINCIPAL LIGHTING DESIGNER (Signature) (Lie. #) (Date) LIGHTING MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures: CERTIFICATE OF COMPLIANCE (part 2 of 2) Project Name: La Costa Products Addition Documentation: Haynal & Co., Inc. LTG-1 page 12 of 21 Date: 2/23/1994 COMPLY 24 User 2875 INSTALLED LIGHTING SCHEDULE No of Watts/ Ballast Name Lamp Type Lamps Lamp Type Ballasts/ No of Note to Luminaire Fixt. Field Fluorescent 32 Standard 1.5 12 MANDATORY AUTOMATIC CONTROLS Control Control Location ID Control Type Space Controlled _Typical Note to Field Wall Dual Switch CONTROLS FOR CREDIT Control Control Location ID Control Type Space Controlled Note to Field N/A LIGHTING COMPLIANCE SUMMARY Project Name: La Costa Products Addition Documentation: Haynal & Co., Inc. LTG-2 page 13 of 21 Date: 2/23/1994 COMPLY 24 User 2875 ACTUAL LIGHTING POWER Name Description No of Watts Total Lumin per Default Watts 48" T-8 Straight /3 Lamp (Tandem) 12 106.5 SubTotal Less Control Credits (LTG-3) Total Proposed Watts * If not CEC Default value, please provide supporting documentation. 1278 1278 0 1278 MODELLED LIGHTING POWER BY SPACE Space Name Occupancy Modelled Floor LPD Total Tailored Area (w/sf) (watts) (watts) Office Addition Office TOTALS 790 1.618 1278 790 1.618 1278 0 0 * Note: Tailored Allotment requires supporting documentation on form LTG-4, CERTIFICATE OF COMPLIANCE (part 1 of 3) MECH-1 page 14 of 21 Date: 2/23/1994 Project Name: La Costa Products Addition Address: 2875 Loker Avenue East Carlsbad, CA Mechanical Designer: Documentation: Haynal & Co., Incf; Building Permit No Checked by / Date COMPLY 24 User 2875 GENERAL INFORMATION Date of Plans: Building Conditioned Floor Area: 790 sf Building Type: Nonresidential Climate Zone: 7 Phase of Construction: 0 New Construction p^'JCddition 0 Alteration Method of Mechanical Compliance: Performance - COMPLY^Sri-v 4.11 Proof of Envelope Compliance: 0 Previous Permit Q^ompliance Attached STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Part 6, Chapter 1 and Title 20, Chapter 2, Subchapter 4, Article 1 of the California Code of Regula- tions. This certificate applies only to building mechanical recjuirements. The Principal Mechanical Designer hereby certifies that the proposed build- ing design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the mechanical requirements contained in sections 110 through 115, 120 through 124, 140 through 142,144 and 145. Please check one: 0 I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a civil engineer mechanical engineer or architect. 0 I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing docu- ments for work that I have contracted to perform. 0 I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section of the ^_ Code to sign this document as the person responsible for its preparation; and for the following reason: . PRINCIPAL MECHANICAL DESIGNER (Signature) (Lie. #) (Date) MECHANICAL MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures: CERTIFICATE OF COMPLIANCE (part 2 of 3) Project Name: La Costa Products Addition Documentation: Haynal & Co., Inc. MECH-1 page 15 of 21 Date: 2/23/1994 COMPLY 24 User 2875 SYSTEM FEATURES Zone Name Time Control Setback Control # of Isolation Zone HP Thermostat Electric Heat Fan Control VAV Min Position Simul. Heat/Cool Heat Supply Reset Cool Supply Reset Ventilation OA Damper Control Economizer Type Outdoor Air CFM Heat Equip Type Make & Model No. Cool Equip Type Make and Model Note to Field Office Addition S None sn/a Yes 7.5 KW Constant Volume n/a n/a Constant Temp Constant Temp C A No Economizer 119 Heat Pump Carrier 50NQ030 DX Code Tables Time Control S:Prog Switch 0:Oec Sensor M:Man Timer Ventilation B:Air Balance C:OA Cert. M:OA Measure D:Demand Cont N:Natural OA Damper A:Auto G:Gravity CERTIFICATE OF COMPLIANCE (part 3 of 3) Project Name: La Costa Products Addition Documentation: Haynal & Co., Inc. MECH-1 page 16 of 21 Date: 2/23/1994 COMPLY 24 User 2875 DUCT INSULATION System Name Type Duct Location Duct Tape Insul Note to Allowed R-Val Field Carrier 50NQ030 Heating Ducts in Attic Cooling Ducts in Attic Y/N Y/N 4.2 4.2 PIPE INSULATION System Name Domestic Hot Water Pipe Type Insul Required Y/N Note to Field NOTES TO FIELD - For Building Department Use Only MECHANICAL EQUIPMENT ZONING SUMMARY MECH-2 page 17 of 21 Project Name: La Costa Products Addition Date: 2/23/1994 Documentation: Haynal & Co., Inc. COMPLY 24 User 2875 SYSTEM/ZONING SUMMARY No Zone/Spaces Served Central/Zonal System System Type Sys Office Addition Office Addition Warehouse Carrier 50NQ030 Packaged Heat Pump 1 MECHANICAL EQUIPMENT SUMMARY Project Name: La Costa Products Addition Documentation: Haynal & Co., Inc. MECH-3 page 18 of 21 Date: 2/23/1994 COMPLY 24 User 2875 PLANT EQUIPMENT SUMMARY Equipment Name Equipment Type Std Gas 50 gal or Less Gas Fired No. Sys Fuel Input (KBtu) 40.0 Elec Input (KW) 0.0 Total Output (KBtu) 31.2 CENTRAL SYSTEM SUMMARY Sys No System Name No System Type Sys Economizer Type Packaged Heat Pu 1 No Economizer 1 Carrier 50NQ03 0 CENTRAL SYSTEM RATINGS Sys Heating No Type Output Aux KW EFF 7.5 6.70 DX Cooling Type Output Sensible EER SEER 1 Heat Pump 29400 29400 22050 9.10 10.00 CENTRAL FAN SUMMARY Sys No Fan Type Motor Location Supply Fan -• CFM BHP 1 Constant Volume Draw-Through 1000 0.20 60 100 Mtr Drv Eff Eff Return Fan Mtr Drv CFM BHP Eff Eff None ZONAL FAN SUMMARY Space Name None No Zonal Fan Exhaust Fan Mtr Drv Mtr Drv CFM BHP Eff Eff No CFM BHP Eff Eff MECHANICAL VENTILATION MECH-4 page 19 of 21 Project Name: La Costa Products Addition Date: 2/23/1994 Documentation: Haynal & Co., Inc. COMPLY 24 User 2875 VENTILATION SUMMARY BY Space Name SPACE T Occupancy Floor Area sqft /Occ Tran CFM Min Design sfer /Occ CFM CFM CFM Office Addition Office 790 143 21.5 119 119 TOTALS 119 119 Note: If Tailored (T=*), user must document sqft/Occ and/or CFM/Occ values, HVAC ZONE HEATING & COOLING LOAD SUMMARY Project Name: La Costa Products Addition Documentation: Haynal & Co., Inc. page 20 of 21 Date: 2/23/1994 COMPLY 24 User 2875 HVAC ZONE DESCRIPTION HVAC Zone Name: Heating System Name: Cooling System Name: System Multiplier: Fan Schedule: Peak Load Method: Relative Humidity: SPACES IN THIS ZONE Office Addition Warehouse PEAK (Jan 12am) (Jan 12am) TOTAL SPACE LOAD Duct Gains & Losses: Ventilation: ( 113 CFM) Return Air Lighting Gain TOTAL SYSTEM LOAD HEATING 8105 0 8105 810 3894 12809 Office Addition Carrier 50NQ030 Day Fans STD COINCIDENT 50 % PEAK (Aug 10am) (Aug 10am) COOLING SENSIBLE 13183 0 13183 1318 122 0 14623 LATENT 564 0 564 144 708 SYSTEM OUTPUT AT DESIGN CONDITIONS 49698 22916 8905 NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment which will heat or cool this zone during the design conditions indicated. These numbers include no safety factor, and the HVAC contractor should oversize by a reasonable margin to account for variations in weather conditions and the pick-up capacity required to bring the zone to temper- ature as a result of a setback thermostat. Those responsible for final ecjuipment selection should note that Sensible and Latent Cooling Loads are indicated to allow for accurate comparison with manufacturer's output data. SPACE HEATING & COOLING LOAD SUMMARY Project Name: La Costa Products Addition Documentation: Haynal & Co., Inc. page 21 of 21 Date: 2/23/1994 COMPLY 24 User 2875 SUMMARY OF PEAK HOUR LOADS FOR SPACE Space Name: DESIGN CONDITIONS Peak Hour: Indoor Conditions: Outdoor Conditions: LOAD COMPONENT Office Addition Quantity HEATING Jan 12am 70 F DB 38 F DB Btu/hr COOLING SENSIBLE LATENT Aug 10am 78 F DB 79 F DB Wall Conduction 638 .0 sqft 495 342 Window Conduction 132 .0 sqft 4646 -16 Door Conduction 0 .0 sqft 0 0 Roof Conduction 0 .0 sqft 0 0 Skylight Conduction 0 .0 sqft 0 0 Floor Conduction 0 .0 sqft 0 0 Slab Conduction 790 .0 sqft 2965 0 Interior Conduction 0 .0 sqft 0 0 Infiltration 0 .0 AC/hr 0 0 Solar Gain 132 .0 sqft 0 8135 Lighting 1278 .0 watts 0 2668 Receptacle 790 .0 watts 0 1348 Process 0 .0 watts 0 0 Occupants 5 .6 occs 0 705 50 % RH 63 F WB Btu/hr Btu/hr SPACE LOADS 8105 13183 564 564 Heating AirFlow: Cooling AirFlow: 8105 Btu/hr / [1.08 x 13183 Btu/hr / [1.08 x 35 F DeltaT)] = 23 F DeltaT)] = 215 Cfm 532 cfm MANDATORY REQUIREMENTS ENVELOPE MANDATORY MEASURES (NONRESIDENTIAL) 1. Exterior manufactured doors, windows, and fenestration products stiall meet tfie infiltration and U-value certification requirements of Section 116(a). 2. Site-constructed doors, skyliglits, and windows shall be caulked and weather-stripped per Section 116(b). 3. All joints and openings which are potential sources of air leakage shall be caulked, gasketed, weather-stripped or otherwise sealed to limit infiltration and exfiltration per Section 117. 4. Certified insulation materials per Section 118(a). 5. Urea Formaldehyde foam insulation installed per Section 118(b). 6. Insulation installed to meet flame spread and smoke density requirements per Section 118(c). LIGHTING MANDATORY MEASURES 1. Each enclosed area shall have independent controls (per Section 131 (a) and exceptions). 2. Lighting shall be uniformly reducible by one half in areas which are greater than 100 sf, exceed 1.2 watts/sf, eind have more than one luminaire (per Section 131 (b) and exceptions; exceptions include lights in corridors). 3. Daylit areas larger than 250 sf shall be seperately controlled and uniformly reducible by one half (per Section 131 (c) and exceptions). 4. Seperately metered spaces 5,000 sf or greater shall have automatic shutoff controls (per Section 131 (e), no exceptions). 5. Display lighting shall be seperately switched on circuits that are 20 amps or less (per Section 131 (e), no exceptions). 6. Exterior lighting conti-olled from a lighting panel within the building shall be automatically controlled (per Section 131(Q and exceptions). 7. Pairs of one-lamp and three-lamp fluorescent luminaires shall be tandem-wired where reasonable (per Section 132 and exceptions). MECHANICAL AND PLUMBING MANDATORY MEASURES Equipment and Systems Efficiency 1. HVAC and service water heating equipment shall meet Appliance Efficiency Regulations, per Sections 111 and 112. 2. Piping, except those conveying fluids at temperatures between 60 and 105 degrees F, or within HVAC equipment, shall be insulated in accordeuice witii Section 123. 3. Air handling duct systems shall be sealed in accordance with the SMAGNA HVAC Ducts Consti'uction Standards, Metal and Rexible, 1985, per Section 124(a) and (b). Ducts shall be installed and insulated as provided in UMC, Chapter 10. 4. Pilot lights shall not be installed for natural gas central furnaces, and pool sind spa heaters, per Section 115. Ventilation 1. Every space in a building shall be designed to have outdoor air ventilation according to Section 121(a), (b) and (e). 2. Operation and control of outdoor air shall meet the time-of-occupancy and pre-occupancy requirements of Section 121 (c). 3. When a return plenum is used to distribute outdoor air to a covered HVAC unit, tiie ducted discharge shedl be in accordance with Section 121(d). 4. Systems shall meet the completion and balancing requirements of Section 121 (f). Controls 1. Each space conditioning zone shall be controlled by an individual tiiermostatic conti'ol that responds to temperature within the zone. Heating shall be adjustable down to 55 degrees or lower, and cooling shall be adjustable up to 85 degrees or higher. The conti'ol shall provide a dead-band of 5 degrees between heating and cooling, Section 122(a) and (b). 2. Heat pumps with supplementary electric resistance heaters shall have controls per Section 112(b). 3. Each space conditioning system shall be Installed with an automatic time switch, able to shut off operation during off-hours of up to four hours, per Section 122(e) 1. 4. Thermostat setup and setback controls are required if the summer design dry bulb temperatijre is more than 99 degrees F, or if the winter design temperature is less than 33 degrees, per Section 122(e) 2, and its exceptions. 5. Outdoor air supply and exhaust equipment shall be installed with dampers that automatically close during periods of non-use for the areas served by the equipment, per Section 122(f). 6. Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shedl be designed, installed, and controlled to serve isolation areas, per Section 122(g). SERVICE WATER HEATING SYSTEMS 1. Temperature controls and recirculating pump controls shall meet the requirements of Section 113(a) and (b). 2. Row rates and temperature controls for public lavatories shall meet the requirements of Section 113(b)3. 3. Unfired sen/ice water heater storage tanks and backup tanks for solar water heating shall comply witii Section 113(b)4. -A X o 0 P U7 1 I ? \3 O I I 4ji c o a. O T3 z •si § i O ^ S o TV c r tn 0 3. Ol. 94 OS:49 AM * * C A R L, S B A D MWD F A>C * O 5 INDUSTRIAL WASTE DISCHARGE PERMIT APPLICATION CB No. f^-ZC^ APPL N0> _ BUSINESS NiAMg <;>y^T?^ lPP^(H':r^ SITE ADDRESS g^7^^ ^fjC 7?f^Ch'7n> I hJT U CONTACT PERSON (at business) ^ . /x^ rF> PHONE NUMBER , <=?<^/ /// Type of Businoss (check all that apply) • Agricultural D Government G Photo Lab • Assembly • Laboratory U Retail • Automotive • Laundry • Sen/Ice Station • Chemical Handling • Manufacturing • Warehouse . • Electronics • Medical • Other • Food • Metal Work • 0t)ffl< DESCRIBE WASTE OTHER THAN DOMESTIC (Chemicals, Particulates, etc.) ce DESCRIBE BUSINESS AnTMTYr -7*^7) Ai^C^ GENERAL DESCgy^N OF ONSITE WASTEWATER PROCESSING: (chemical & physical characteristics). Is business presently In operation at site? H^ES • NO — _ Has Wastewater Discharge Pernilt been applied for through the Encina Water Authority? • YES U NO Applicant's Namef^^v^^mv^ fUf^^AT^ Title ...At^/ff PHone ^ll"} Please Print Agency; f?K^Ac , ' Signature;/Wl^/f '07^/-'''''^ 7—Date ^-Z-T-^t nurture 9f City ^re^tatlve EXEMPT O NOT EXEMPT Date fonwarded to Encina. Date. Hazardous Materials - SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE Management Division Business Name Contact Person Telephone Mailing Address City State Zip Plan Flla# Site Address City / State Zip Plan Fi/e# PART I: FIRE DEPABTMENT - HAZARDOUS MATERIALS MANAGEMENT DIVISION: OCCUPANCY CLASSIFICATIOfg Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. 1. Explosive or Blasting Agent* 4. Rammable Solid* 2. Compressed Gases 5. Organic Peroxides 3. f^lammable or Combustible Uquid* 6. Oxidizer* 7. Pyrophorics 10. Cryoganic* 8. Unstable Reactive* 11. Highly Toxic or Toxic Materials 9. Water Reactive* 12. Radioactive* 13. Corrosives 14. Other Health Hazards PART II: COUNTY OF SAN DIEGO HEALTH DEPARTMENT - HAZARDOUS MATERIALS MANAGEMENT DIVISION: CONTINGENCY PLAN REVIEW: If the answer to any of the question* i* ye*, applicant mu*t contact the County of San Diego Hazardou* Materials Management Division, 1 255 Imperial Avenue, 3rd Floor, San Diego, CA 92186-5261. Telephone (619) 338-2222 prior to the iesuence of a building permit. FEES MAY BE REQUIRED Yes No 1.1—I i* your bu*ina** li*tad on th« raver** *ida of thi* form? 2.1—I Will your bu*ine** di*po** of Hazardou* Sub*tanc** or Medical Wa*t* in any amount? 3. r—I Will your bu*ine*s stor* or handl* Hazardou* Sub*tance* in quantities *qual to or greater than 55 gallon*, 500 pound*, 200 cubic fe*t or carcinogene/reproductiv* toxin* in any quantity? 4 I—1 r^T^Will your bu*ine** u** an •xi*ting or iiwtoil an undarground *toraga tank? 5 r~~l n^Will your bu*in*** *tor* or handl* Acutely Hazardou* Matarial*? OFFICE USE ONLY I I RMPP Exempt / Data Initials Q RMPP Required > Data Initials {~1 RMPP Completed I Date Initials PART III: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT If the answer to any of tha queation* i* ya*, applicant mu*t contact tha Air Pollution Control Oiatrict, 9150 Cheeapeake Drive, San Diego, CA 92123. Tel«phone (619) 694-3307 prior to the i**uanc* of a building pennit. YES NO 1. pn Will the intended occupant inatall or u*c any of the equipment lietod on th* Usting of Air Pollution Control Di*trict Permit Categorie*, on the --^ revere* side of this form? 2. r?T(ANSWER ONLY IF QUESTION 1 IS YES.) Will th* *ubi*et facility b« located within 1,000 feet of the outer boundary of a school (K through 12) as listed in th* eurrertt Directory of School arxl Community Collage Diatrict*. publi*h*d by th* San Diego County Office of Education and th* current California Privat* School Oiraetory, compiled in oceordanc* with proviwon* of Education Code Section 331907 Name of Own*r or Authorized Agent: BneTITjBScriBSTS Signature of Owner 0{^uthQ(ui and correct Oo not write below thi* Una d*r p*rMity of perjury that to th* beat of my krtowledge and belief the reepon*** made harein are true Cat.: ^-^5' -^D FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:^ BY; Data: EXEMPT mOM PEMMIT REQUNEMBilTS COUNTY-HMMO APCD APPROVCD FOR lULOINa PBtMIT BUT NOT OCCUPANCV COUNTY-HMMO APCD APmovED ran OCCUPANCY COUNTY-HMMO APCD EaviroamaiUl Health Setvices DHS: HM-9171 (6/92) CouDQr of Sn Diefo Dqiailawat of Heakh Servicei