Loading...
HomeMy WebLinkAbout2875 LOKER AV EAST; B; CB951115; PermitBUILDINGPERMIT 09/18/95 11:24 Page 1 of 1 Job Address: 287 5 LOKER AV EAST Suite: B Permit Type: INDUSTRIAL TENANT IMPROVEMENT Parcel No: 209-083-10-00 Lot#: Valuation: 83,760 Occupancy Group: Reference*: Description: 7497 SF TENANT IMPROVEMENT Appl/Ownr DESIGN BUILD 9770 CARROLL CENTER ROAD #B SAN DIEGO, CA. 92126 619 Permit No: CB951115 Project No: A9501619 Development No: 3716 09/13/95 0001 01 02 Construction Status Applied Apr/Issue Entered By 549-8455 VN i4'00 ISSUED 08/15/95 09/12/95 MDP *** Fees Required *** *** Fees Collected & Credits * * * Fees: y, 6 39.on Adjustments: .00 Total Credits: . 00 Total Fees: 9,639.00 Total Payments: 9,625 . 00 Balance 14 . 00 Fee description Units Fee/Unit Ext fee Data Building Permit 568 . 00 Plan Check 369 . 00 Strong Motion Fee 18 . 00 Enter Number of EDU's - Water Fee 1 .14 2736 . 00 (Licen:^e fund) 1503 . 00 (Lie Tx CFD fund) 1388 . 00 (TIF Fundi 583 . 00 (TIF CFD Fund) f 539 . 00 Enter Bridge Fee 1734.00 1734 . 00 * BUILDING TOTAL 9438 . 00 Enter "Y" for Plumbing Issue Fee > 20 . 00 Y Each Plumbing Fixture or Trap > / , 00 4 2 . 00 Each Install/Repair Water Line > 7 . 00 7 . 00 Gas Piping System > ^^^*****i 7 . 00 7 . 00 * PLUMBING TOTAL 76 . 00 Enter "Y" for Electric Issue Fee > 10 . 00 Y Remodel/Alter Per AMP > 300 25 75 . 00 * ELECTRICAL TOTAL 85 . 00 Enter 'Y' for Mechanical Issue Fee> 15 . 00 Y Install Furn/Ducts/Heat Pumps > 2 9 . 00 18 . 00 Each Exhaust Fan > 1 6 . 50 6 . 50 * MECHANICAL TOTAL 40 . 00 INSP. CLEARANCE L APPROVAL -DATE-^;^ CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 09/12/95 12 Page 1 of Job Address Permit Type Parcel No: Valuation: BUILDING PERMIT : 30 1 : 2875 LOKER AV EAST Suite: B : INDUSTRIAL TENANT IMPROVEMENT 209-083-10-00 Lot#: 83,760 Permit No Project No Development No CB951115 A9501619 Occupancy Group: Description: 7497 SF TENANT Reference* IMPROVEMENT Appl/Ownr : DESIGN BUILD 9770 CARROLL CENTER ROAD #B SAN DIEGO, CA. 92126 619 3626 09/12/95 0001 01 02 C-PRHT 8993-00 Construction Type: VN Status: ISSUED Applied: 08/15/95 Apr/Issue: 09/12/95 Entered By: MDP 549-8455 *** Fees Required *** *** Fees Collected & Credits * * * Fees: y.625.00 Adjustments: .00 Total Credits: 00 Total Fees: 'r^, 626. 00 Total Payments: 632 . 00 Balance Due: 8,993. 00 Fee description Units Fee/Unit Ext fee Data Building Permit 568. 00 Plan Check 369 . 00 Strong Motion Fee 18 . 00 Enter Number of EDU's - Water Fee > 1 . 14 2736 00 (License fund) 1503 . 00 (Lie Tx CFD fund) 1388 00 (TIF Fund) 583 00 (TIF CFD Fund) 539 00 Enter Bridge Fee 1734.00 1734 00 * BUILDING TOTAL 9438 00 Enter "Y" for Plumbing Issue Fee > 20 00 Y Each Plumbing Fixture or Trap > 4 7,00 28 00 Each Install/Repair Water Line > 1 7.00 7 00 Gas Piping System > 1 7.00 7 00 * PLUMBING TOTAL 62 00 Enter "Y" for Electric Issue Fee > 10 00 Y Remodel/Alter Per AMP > 300 .25 75 00 * ELECTRICAL TOTAL 85 . 00 Enter 'Y' for Mechanical Issue Fee> 15 . 00 Y Install Furn/Ducts/Heat Pumps > 2 9.00 18 . 00 Each Exhaust Fan > 1 6.50 6 . 50 * MECHANICAL TOTAL 40 , 00 •MS FINAL APPROVAL DATE — CLEARANCE CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 09/12/95 12:31 Page 1 of 1 Job Address: 2875 LOKER AV EAST Permit Type: SEWER - OFFICE/WAREHOUSE Parcel No: 209-083-10-00 Suite: B Permit No: SE950072 BIdg PlanCk#: CB951115 3626 09/12/95 0001 01 02 C-PRMT 2146.00 Description: 7497 SF TENANT IMPROVEMENT Permitee: DESIGN BUILD 977 0 CARROLL CENTER ROAD #B SAN DIEGO, CA. 92126 *** Fees Required *** Fees: 2,14r..00 Adjustments: .00 Total Fees: .i. 146. 00 Fee description *** Status: ISSUED Applied: 08/21/95 619 549-8455 Apr/Issue: Expired: Prepared By: Enter Office Square Footage > <Enter CREDIT EDU3> > Total EDUs Sewer Fee Enter Sewer EDUs and Benefit Area > * SEWER TOTAL Fees Collected & Credits 09/12/95 HE * * * Total Credits: Total Payments: Balance Due: Units Fee/Utxit 3177 . 63 1 . 14 . 00 . 00 2,146.00 Ext fee Data 1.77 -.63 1. 14 2059.00 87 . 00 2146.00 CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 PERMIT APPUCATION City of Carlsbad Building Departaent 2075 Las Palaas Dr.. Carlsbad, CA 92009 (619) 438-1161 1. PKHMlT'lVPE From List 1 (see back) give code of Permit-Type: For Residential Proiects Only: From List 2 (see back) give Code of Structure-Type: Net Loss/Gain of Dwelling Units. PLAN CHECK NO. <^ ^ ^ 111 ^ EST. VAL PLAN CK DEPOSn: VALID. BY_ DATE 2. PROIECT INFORMATION 3196 08/.15/95 0001 01 02 C-PRHT FOR OFHCE USE ONLY Address j^^y^ ^A^/Se Buudi^or suite NO. Nearest Cross Street ^y^^/^^^ /f ^^^'''^' .'^^^^ LEGAL DEiJCWPTlON Lot No. Subdivision Name/Number Unit No. Phase No. :K BELOW IF SUMITI'EU: ^-^--^ ^ • 2 Structural Calcs O 2 Soils Report • 1 Addressed Envelope CHECK • 2 Energy Calcs ASSESSOR'S PARCEL DESCRIPTION OF WORK SQ. FT. : OF STORIES 3. UJNIALT PKHiUN Ul ditterent trom applicant) RXISTINO USE PBOPOSF.n USE # OF BEDROOMS # OF BATHROOMS NAME (last name flrsO CITY L,ni / STATE z.ir VJUUC UAI lE.iJii'nuiNn APPUCIANT TOON'l'UALTOR—U AUEN'l' t'UR mN'i'UAL'im—UOWNER—U AtiENT FOR OWNER NAME (last name firs0 2>£^/^r/t^7fi^U7> 7r.i:ADDRESS ^yyO r:?/f^^>U-<2£^7S:^ ADDRESS ZIP CODE DAY TELEPHONE CITY >/^<3?£? STATE ZIP CODE •7770 r^^yf^'i^U-ii^T^ne, TZa/f JP TELEPHONE CITY S^/lJ2?/i5SC> STATE d/^ ZIP CODE ^//^^ DAY TELEPHONE ^ ^ 3" NAME (last name first) ^^j;,^;;^^^^^^^^ MiTi^S <pyya <7^^'^^^l- ^£>^^y^ ^T^ "l?/£(^0 STATERZIP CODE /^A .^<^^i^ DAY TELEPHONE 3~y'5^-aP^j5'3~ STATE UC. #-^^^^^yuCENSE CLASS CITY BUSINESS UC. # UEyiONER NAME (last name hrstj ADDRESS CITY 7. WORKERS'OOMPENi^A'nON STATE ZIP CODE DAY TELEPHONE STATE UC. # Workers' Compensation Declaration: 1 hereby attirm that 1 have a certificate ot consent to selt-insure issued by the Director ot industrial Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, lab. C). ^ ^ J A7Ui3.3/9^^^^ ^ «-,/^ INSURANCE COMPANY (yg/.2:g>Z/ S7?-ii L£: POUCY NO. EXPIRATION DATE ZP/B //y(i> ' Certificate ot Exemption: I certify that in the pertormance ot the work tor which this permit is issued, 1 shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of Califomia. SIGNATURE 8. OWKER-BinLDERUEOARA'llON DATE uwner-uuiider ueciarauon: i nereoy attirm that i am exempt trom the contractors ucense Law tor tne following reason: I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (S«:. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section . Business and Professions Code for this reason: SIGNATURE (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to ilie provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefix)m, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applipnU:o ^^^^;:^nalty ofnptpmo^ than five hundred dollars [$500]). DATE COMPLETE THfS S'ECl'lON FOR NON^ESlDEN-nAL BUILDlKfl PERMITS ONLV: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? • YES • NO Is the applicant or fiiture building occupant required to obtain a permit from the air pollution control district or air quality management district? O YES • NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? • YES • NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIHCATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1,1989 UNLESS THE APPUCANT HAS MET OR IS MEETING THE REQUIREMENTS OP THE OFHCE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 9. UON«.'mUt:nON LENDING A0KNL7 ~ I hereby attirm that there is a construction lending agency tor the pertormance ot the work tor which this permit is issued (Sec 3097(1) Cml Code). LENDER'S ADDRESS LENDER'S NAME 10. APPUCJANTCER'lli'lOvnuw I certify that 1 have read the application and state that the at)Ove information is correct. 1 agree to comply with all city ordinances and btate laws relating to building construction. I hereby authorize representatives of the Cityof Carlsbad to enter upon die above mentioned property for inspection purposes. I AI£0 AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CTTY OF CARLSBAD AGAmCT ALL UABILmES, AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINCT SAID OTY IN OONSEQtraiCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over S'O" deep and demolition or construction of structures over 3 stories in height. Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such pennit is not commenced within 365 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned wany time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code). APPUCANTS SIGNATURE sJli //\||| , AD<I.. ^^^^ DATE: f-fT't^* WHITE: File YELLOW: ppiicant PINK: Finance PERMIT APPUCATION City of Carlsbad Building Departaent 2075 Las Palaas Dr., Carlsbad, CA 92009 (619) 438-1161 1. PERMIT-IVPU From List 1 (see back) give code of Permit-Type: For Residential Proiects Only: From List 2 (see back) give Code of Structure-Type: Net Loss/Gain of Dwelling Units. 2. PROJECT INFORMATION ^ Address J^^TS" ^l^'^ ""Building or Suite No. ^ Nearest Cross Street Lot No. Subdivision N< PLAN CHECK NO. EST. VAL PLAN CK DEPOSIT VALID. BY DATE FOR OFFICE USE ONLY LEGAL DEJJiJRlM'lON ame/N umber Unit No. Phase No. t^HEOK BELOW ll-' aUBMl'lTEU: • 2 Energy Calcs O 2 Structural Calcs • 2 Soils Report • 1 Addressed Envelope ASSESSOR'S PARCKT. DESCRIPTION OF WQRK Aki- F//»l SiK < *^ SQ. FT. # OF STORIES # OF BEDROdMS # OF BATHROOMS 3. LUNTALT PEHSUN (it diflerent trom applicant) NAME (last name firsO CITY 4. APPUCANT NAME (last name 1^ STATE ADDRESS ZIP CODE DAY TELEPHONE [CONTRAC'im . UAUENT FOR CON'l'RACmi fi''t>/Ca«^lcc/*iWf^ ^^^^ STATE 5. PROPERTY OWNER—'Ti.A ^/J- NAME (last name first) '^-^fl-«" rRAC'im—• OWNER—DAUENTEOR OWNER CITY ZIP CODE DAY TELEPHONE ADDRESS CITY 6. ooN'mAtrim STATE ZIP CODE DAY TELEPHONE St:^ H^^^ffO STATE ZIP CODE ^P/"^^ DAY TELEPHONE ^^ftf^^S^ STATE UC. # NAME (last name CITY UCENSE CLASS CITY BUSINESS UC. # DESIONER NAME (last name tirst) CITY AUUKtSS STATE ZIP CODE DAY TELEPHONE STATE UC. # Workers' Compensation Declaration: 1 hereby attirm that 1 have a certificate of consent to self-Insure issued by the Director ot Industnal Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C). INSURANCE COMPANY PQUCYNO. EXPIRATION DATE Certiticate ot Exemption: 1 certify that in the performance ot the work for which this permit Is Issued, 1 shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of Califomia. SIGNATURE . OWNER-BUILDER DKClARA'llON DATE Uwner-Duiider ueciarauon: I hereby attirm tnat i am exempt trom tne (contractors License Law tor tne following reason: • I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.). • I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). • I am exempt under Section Business and Professions Code for this reason: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commencing widi Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$S00]). SIGNATURE DATE COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLV: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? • YES • NO Is the applicant or future building occupant required to obtain a pennit fi-om the air pollution control district or air quality management district? • YES • NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? • YES • NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1,1989 UNLESS THE APPUCANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFHCE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISnUCT. 9. UUNymUL'llONLENUlNOACENa 1 hereby affirm that there is a construction lending agency for the pertormance of the work tor which this permit is issued (Sec 3097(1) Cml Code). TO LENDER'S NAME APPUl^T OJR'HFltWnON LENDER'S ADDRESS 1 ceruty that I have read the applicauon and state that the above information is correct, i agree to comply with all Uty ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE OTY OF CARLSBAD AGAMCT ALL UABILmES, JUDGME AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINSr SAID OTY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over S'O" deep and demolition or construction of structures over 3 stories in height. Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized_bysuch p^^ is not commenced within 365 days from the date of such permit or if the building or work authorized by such permit is lusaeadeir^jLtehdtJfi^^apy n'nie after the work is commenced for a period of 180 days (Section 303(d) Uniform Buildina Co(te). Ffle YELLOW: ppiicant PINK: Finance CITY OF CARLSBAD INSPECTION REQUEST PERMIT* CB951115 FOR 10/18/95 DESCRIPTION: 7497 SF TENANT IMPROVEMENT TYPE: ITI JOB ADDRESS: 2875 LOKER AV EAST APPLICANT: DESIGN BUILD PHONE: CONTRACTOR: PHONE: OWNER: PHONE: REMARKS: BJN/RANDY/493-9544 INSPECTOR SPECIAL INSTRUCT: P.M. INSPECTION PLEASE INSPECTOR AREA TP PLANCK# CB951115 OCC GRP CONSTR. TYPE VN STE: B /I LOT: 619 549-8455, TOTAL TIME: —RELATED PERMITS— PERMIT# SE950072 TYPE SWOW AS950058 ASTI FAD95017 FADD STATUS ISSUED ISSUED ISSUED CD LVL DESCRIPTION 19 29 39 49 ST Final Structural PL Final Plunbing EL Final Electrical ME Final Mechanical ACT COMMENTS ***** INSPECTION HISTORY ***** DATE DESCRIPTION ACT INSP COMMENTS 100595 Final Combo CO TP SEE CORR LIST 100395 Rough/IXicts/Dampers AP TP PER REV.DUCTS ONLY 092995 Fraaie/Steel/Bolting/Welding AP TP T-BAR GRID 092995 Rough Electric AP TP CEILING LITES 092995 Rough/Ducts/Dampers PA TP ND AS BUILT REV. 092295 Interior Lath/Drywall AP PK VERIFY TOP TRACK SCREWS 091995 Frame/Steel/Bolting/Welding AP TP PER PLAN REV 091995 Rough/Topout AP TP 091995 Rough Electric AP TP WALLS 091995 Rough/Ducts/Dampers NR TP 091995 Underground/Under Floor AP TP PER PLAN REV 091595 Fra»e/Steel/Bolting/Welding CO TP SEE JOB CARD 091595 Rough/Topout CO TP 091595 Rough Electric CO TP DEPT: BUILDING FINALBm,DING INSPECTION ENGINEERING/^^ FIRE ) PLANNING U/M WATER PLAN CHECK!: CB951115 PERMIT#: CB951115 PROJECT NAME: 7497 SF TENANT IMPROVEMENT ADDRESS: 2875 LOKER AV EAST SUITE# B CONTACT PERSON/PHONE*: BJN/RANDY/493-9544 SEWER DIST: CA WATER DIST: CA INSPECTED BY: ^1 A^:J< INSPECTED BY: INSPECTED BY: DATE INSPECTED: DATE INSPECTED: DATE: 10/18/95 PERMIT TYPE: ITI DATE . INSPECTED: f^/fS APPROVED APPROVED APPROVED DISAPPROVED DISAPPROVED DISAPPROVED COMMENTS: EsGil Corporation Professional Plan Review Engineers DATE: 8/31/95 ojAP^ANT JURI^ • FIRE JURISDICTION: Carlsbad Sl-PllAN REVIEWER • FILE PLAN CHECK NO.: 95-1115 SET: II PROJECT ADDRESS: 2875 Locker Avenue PROJECT NAME: Pacific Trientics T.I. ^ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to fonward to the applicant ^ contact person. I I The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. I I Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Date contacted: (by: ) Telephone*: • REMARKS: By: David Yao Enclosures: Esgil Corporation • GA • CM • GP • PC log trnsmtl.dot 1 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (619)560-1468 • Fax (619) 560-1576 EsGil Corporation • APPLICANT ^gsJOfit^r^ • FIRE • PLAN REVIEWER • FILE Professional Plan Review Engineers DATE: 8/21/95 JURISDICTION: Carlsbad PLAN CHECK NO.: 95-1115 SET: I PROJECT ADDRESS: 2875 Locker Ave PROJECT NAME: Pacific Trientics T.I. I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. IXI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ^ The applicant's copy of the check list has been sent to: Design Build T.I. 9770 Carroll Center Road Suite B San Diego CA 92126 IXI Esgil Corporation staff did not advise the applicant that the plan check has been completed. I I Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Date contacted: (by: ) Telephone #: • REMARKS: By: David Yao Esgil Corporation 13 GA lEl CM • GP • PC 8/17 Enclosures: trnsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (619)560-1468 • Fax (619) 560-1576 Carlsbad 95-1115 8/21/95 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 95-1115 OCCUPANCY: B-2 TYPE OF CONSTRUCTION: V-N ALLOWABLE FLOOR AREA: SPRINKLERS?: Y REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 8/21/95 JURISDICTION: Carlsbad USE: office/manufacture/warehouse ACTUAL AREA: 3177/3600/720 STORIES: HEIGHT: OCCUPANT LOAD: DATE PLANS RECEIVED BY ESGIL CORPORATION: 8/17 PLAN REVIEWER: David Yao FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1991 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303 (c), 1991 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. LIST NO. 40, TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1991 UBC) tiforw.dot Carlsbad 95-1115 8/21/95 1. Please make all corrections on the original tracings and submit two new sets of prints, to: Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, CA 92123, (619) 560-1468. 2. Note on plan that suspended ceilings shall comply with UBC Tables 47-A and 23-P. 3. Note on the plans: "All exits are to be openable from inside without the use of a key or special knowledge". In lieu of the above, in a Group B occupancy, you may note "Provide a sign on or near the exit doors reading THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS". This signage is only allowed at the main exit. Section 3304(c). 4. If non-rated corridors are used per Section 3305(g), Exc. 5, provide a reference to the corridors on the floor plan, noting: a) Smoke detectors shall be maximum 30' on center. b) Power supply shall be dedicated branch circuit. Circuit disconnecting means shall be accessible only to authorized personnel and shall be clearly marked FIRE ALARM CIRCUIT CONTROL, with a lock-on device. 5. If a tenant space utilizes Section 3305(g), Exception 5, then that tenant space shall be separated from adjacent spaces by a demising wall constructed as for a one-hour corridor wall.(20 minutes door, 3/4hrs window and the 5/8" type 'X' gyp. shall be all the way to the roof or floor struture.) • MISCELLANEOUS 6. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 7. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes • No • 8. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact David Yao at Esgil Corporation. Thank you. Carlsbad 95-1115 8/21/95 ELECTRICAL PLAN REVIEW PLAN REVIEWER : Chuck Mendenhall 1. Show the ampere interrupting capacity (AlC ) ratings of the subservice equipment. NEC 110-9, 230-65. 2. Show or note on the plans the method used to limit fault currents to 10,000 amps on all new branch circuits. Show the fuse letters if used to limit fault current (i.e., JJN, AST, LPN).. 3. Show the grounding electrode conductor size and wire type (AL/CU) for the transformer secondary system. NEC 250-94. 4. Specify the" nearest electrode" used for each transformer secondary ground system (i.e., building steel, cold water pipe). NEC 250-26(c). 5. Specify the wiring method you intend to use for this project (i.e., EMT, Metal Flex, NMC etc.). 6. Show the location of panel 'HI'. NEC 110-16,240-24,300-21. 7. Provide overcurrent protection on the secondary side of transformers. NEC 240-21 Ex., 384-16(d). This applies to the new transformer. 8. Provide receptacle(s) within 25 feet of HVAC equipment. UMC 509. Note: If you have any questions regarding this electrical plan review list please contact Chuck Mendenhall at (619) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. PLUMBING, MECHANICAL AND ENERGY CORRECTIONS PLAN REVIEWER: Glen Adamek • PLUMBING (UNIFORM PLUMBING CODE) 1. Provide complete water line sizing calculations, including the water pressure, pressure losses, water demands, and developed pipe lengths. 2. Provide gas line plans and calculations, showing pipe lengths and gas demands. UPC Section 1219. Carlsbad 95-1115 8/21/95 3. Provide drain, waste and vent plans. 4. Show 1/4 inch per 12 inch slope on drain and waste lines. UPC Section 407. 5. Show water heater size, type and location on plans. UPC, Section 1301. 6. Show that water heater is adequately braced to resist seismic forces. UPC, Section 1310. 7. Show P & T valve on water heater and detail drain line route from P & T valve to the exterior. UPC Section 1007(e). 8. New water closets and associated flushometer valves, if any, shall use no more than 1.6 gallons per flush and shall meet performance standards established by the American National Standards Institute Standard All2.19.2, and urinals and associated flushometer valves, if any, shall use no more than one gallon per flush and shall meet performance standards established by the American National Standards Institute Standard Al 12.19.2. H & S Code, Section 17921.3(b). • MECHANICAL (UNIFORM MECHANICAL CODE) 9. Detail ladder access to roof mounted HVAC equipment. • ENERGY CONSERVATION 10. The plans show over 650 square feet of new restroom, corridor and support areas. More than the 450 square feet shown on the LTG-2 form. Please correct. 11. Lighting in the new lunch room is not shown on the plan and in the energy design. 12. On the plans clearly show the wall and roof insulation locations, thickness, and R-values, as per the energy design. 13. Show the daylit areas and required daylit area lighting controls for lighting in daylit areas. Title 24, Part 6, Section 131(c). Note: If you have any questions regarding this plan review list please contact Glen Adamek at (619) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. Carlsbad 95-1115 8/21/95 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: David Yao BUILDING ADDRESS: 2875 Locker Ave PLAN CHECK NO.: 95-1115 DATE: 8/21/95 BUILDING OCCUPANCY: B-2 TYPE OF CONSTRUCTION: V-N BUILDING PORTION BUILDING AREA (sq. ft.) VALUATION MULTIPLIER VALUE ($) T.I.(office) 3177 Air Conditioning Fire Sprinklers TOTAL VALUE per permit application 85000.00 UBC Building Permit Fee: UBC Plan Check Fee: Comments: $ 572.00 $ 371.8 Sheet 1 of 1 valuefee.dot Citv of Carlsbad Engineering Depsrtment BUILDING PLANCHECK CHECKLIST DATE: (77/74^^ ^ PLANCHECK NO. CB BUILDING ADDftESS: '^r'^S' A^/^gye /7V<^ cTc^/V^T/g PROJECT DESCRIPTION: 7^:2^^ ^^i^^c.^ a/-?!^. Ji-JD H U^iu ASSESSOR'S PARCEL NUMBER: jZ/Tf-EST. VALUE / ^^.^^ APPROVAL The item you have submttted for review has been approved. The approval is based on plans, information and/or specifications provided In your submittal; therefore any changes to these Items after this date, including field modifications, must t)e reviewed t)y this office to insure continued conformaruM with applicable codes. Please review carefully all comments attached, as failure to comply with instructions In this report can result In suspension of permit to build. Q A Right-of-Way permit is required prior to construction of the following improvements: ENGINEERING DEPARTMENT DENIAL Please see the attached report of deficiencies marked with Q Make necessary corrections to plans or specifications for compliance with appllcat}le codes and standards. Submit con'ected plans arid/or specifications to this office for review. By:. Date: By: Date: By:. Date: SYi Q AUTHOHIZATIQN TO ISSUE FOR OrrtClAL USE ONLY DATE. itmiMiitiiMiiSiiiMSSitiiSili ATTACHMENTS Dedication Appttoatlon E] Dedication Checklist Improvement Application Improvement Checklist Future Improvement Agreement Q Grading Permit Application Grading Submittal Checklist Right of Way Pemiit Application ED Right of Way Penult Submittal Checklist and Information Sheet Q Sewer Fee Information Sheet P:\DOCS\CHKLST\BP0001 .FRM ENGINEERING DEPT. CONTACT PERSON NAME: City of Carlsbad ADDRESS: 2075 Las Palmas Dr.. Carlsbad. CA 92009 PHONE : (619^438-1161. Ext. A-4 REV 05/11/94 2075 Las Palmas Dr. • Carlsbad, CA 92009-1576 • (619) 438-1161 • FAX (619) 438-0894 BUILDING PLANCHECK CHECKLIST SITE PLAN 1st/2ndv/ 2ndv/ 3rdy [B^ G D 1. Provide a fully dimensioned site plan drawn to scale. Show: A. North Arrow D. Property Unes Easements B. Existing & Proposed Structures E. Easements C. Existing Street Improvements F. RIght-of-Way Width & Adjacent Streets 2. Show on site plan: A. Drainage Pattems C. Existing Topography B. Existing & Proposed Slopes G 3. Include note: "Surface water to be directed away from the building foundation at a 2% gradient for no less than 5' or 2/3 the distance to the property line (whichever Is less)." [Perl 985 UBC 2907(d)5]. On graded sites, the top of any exterior foundation shall extend above the elevation of the street gutter at point of discharge or the inlet of an approved drainage device a minimum of 12 inches plus two percenr (per 1990 UBC 2907(d)5.). G 4. Include on title sheet A. Site address B. Assessor's Parcel Number C. Legal Description For commercial/industrial buildings and tenant improvement projects, include: Total building square footage with the square footage for each different use, existing sewer pemiits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION P:\DOCS\CHKLS-I\BP0001 .FRM Page 1 Of 4 REV 05/11/94 BUILDING PLANCHECK CHECKLIST DISCRETIONARY APPROVAL COMPLIANCE W 2ndy SrdV M G G 5. Project does not comply with the following Engineering Conditions of approval for /A Project No. Conditions were complied with by: Date: DEDICATION REQUIREMENTS G G 6. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ -pursuant to Code Section 18.40.030. Dedication required as follows: Attached please find an application form and submittal checklist for the dedication process. Provide the completed application form and the requirements on the checklist at the time of resubmlttal. Dedication completed by Date: IMPROVEMENT REQUIREMENTS G G G 7a. All needed public Improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ -pursuant to Code Section 18.40.040. Public improvements required as follows: Please have a registered Civil Engineer prepare appropriate improvement plans and submit them together with the requirements on the attached checklist for a separate plancheck process through the Engineering Department. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of permit. Attached please find an application form and submittal checklist for the public improvements requirements. Provide the completed application form and the requirements on the checklist at the time of resubmlttal. Improvement Plans signed by: ^ Date: P:\DOCS\CHKLST\BP0001 .FRM Page 2 Of 4 REV 05/11/94 BUILDING PLANCHECK CHECKLIST 1sty 2ndv/ 3rd^ G G G 7b. Construction of the public improvements may be deferred pursuant to code Section 18.40. Please submit a recent property title report or cun'ent grant deed on the property and processing fee of $ so we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building Permit. Future public improvements required as follows: 0^ Improvement Plans signed by: Date: G G G 7c. Enclosed please find your Future Improvement Agreement. Please return signed and notarized Agreement to the Engineering Department. Future Improvement Agreement completed by: Date: G G 7d. No Public Improvements required. SPECIAL NOTE: Damaoed or defective imorovements found adiacent to buildina site must be repaired to the satisfaction of the Citv Inspector prior to occuoancv. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. G G G 8a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). G G G 8b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be Submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Buildina Permit. Grading Inspector sign off by: Date: G 8c. No Grading Permit required. P:\I}OCS\CHKLST\BP0001.FRM Page 3 Of 4 REV 05/11/94 BUILDING PLANCHECK CHECKLIST MISCELLANEOUS PERMITS IsV 2nd^/ 3rd>/ G G 9. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, trees, driveways, tieing into public storm drain, sewer and water utilities. Right-of-Way permit required for X A separate Right-of-Way permit issued by the Engineering Department is required for the following: G G 10. A SEWER PERMIT is required concurrent with the buildina permit issuance. The fee is noted in the fees section on the following page. G G 11. INDUSTRIAL WASTE PERMIT is required. Applicant must complete Industrial Waste Permit Application Form and submit for City approval prior to issuance of a Permit. Industrial waste permit accepted by: Date: P:\DOCS\CHiaST\BP0001 .FRM Page 4 of 4 REV 05/11/94 ENGINEERING DEPARTMENT ENGINEERING REVIEW SECTION FEE CALCULATION WORKSHEET CD Estimate based on unconfirmed information from applicant. ^^^^^Calculation based on building plancheck plan submittal. Addressa^^'gjr /-n^£fP> /}(7^ ^'^/^^>^ldg. Permit No. 'fS'/Z/JT Prepared bv: /^"^^ Date:^^^^" Checked hs-.-.^-i,^-^ Date: ^/S EDU CALCULATIONS: List types and square footages for all uses. , ^. . .-^ /. "77 Types of Use: /9n^J»</t/Ser^iiT,,*'ff!i, R./Uiilm. if f/srrT?ti—EDU's; —— ''^^'^ Total EDU's: „ 2.J^^ ADT CALCULATIONS: List types and square footages for all uses. Types of Use: ^/^/^ Sq. R./Units: ^/7'7y /io^ ADTs: FEES REQUIRED: PUBLIC FACILITIES FEE REQUIRED • YES NO (See BuHding Department for amount) WITHIN CFD: G YES (no bridge & thoroughfare fee. ^NO reduced Traffic Impact Fee) PARK-IN-UEU FEE PARK AREA: FEE/UNIT: X NO. UNITS: =$ RAFFIC IMPACT FEE ^ " 7'^7^^ ADTs/UNITS: X FEE/ADT: =S ^^^^^ RIDGE AND THOROUGHFARE FEE 7 737" ADTsAJNITS:^:^^ X FEE/ADT: 39. j^J^j?^ 4. FACIUTIES MANAGEMENT FEE ZONE: <i^' '4 SQ.FT.^^^^ X aB7SQ.FT, 5. SEWER FEE PERMIT No. EDU's: ^^:^^^^r'j^j^ X FEE/EDU: 7/^^ BENERT AREA: DRAINAGE BASIN: «r"<g" EDU's: ..J^S^Jif^ X .ggg/EDU: 7G 6. DRAINAGE FEES PLDA : HIGH /LOW ACRES: X FEE/AC: =$. 7. SEWER LATERAL ($2,500 DEPOSIT) =« TER FEE EDU's: .^r^ X FEE/EDU:, TOTAL OF ABOVE FEES*: %, *NOTE: This calculation sheet i« NOT a complete iiat of all fees which may be due. Dedications and Improvements may also be required with Building Permits. P:\DOCS\MISFORMS\BP0002.FRM REV 01/04/95 Plan Check no/iSjflS^ Planner -^^j^ PLANNING CHECKLIST Address Phone 438-1161 ext. (^'7^^ APN: (Name) Type of Project and Use -""^f^^' Zone Facilities Management Zone CFD (i • « « • a • o a o ^ 1 ^ « Si 8 M M M t % t 5 6 6 i S S Legen4 • CIt property in, complete SPECIAL TAX CALCULATION WORKSHEET provided by Building Department.) Item Complete Item Incomplete - Needs your action 1, 2, 3 Number in circle indicates plancheck number where deficiency was identified 0^G EDvitomnental Review Required: YES NO TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval G Discretionaiy Action Required: YES NO ^/TYPE DATE: APPROVAL/RESO. NO. PROJECT NO. OTHER RELATED CASES: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval J^G G California Coastal Gomnussion Pennit Requized: YES NO / DATE OF APPROVAL: San Diego Coast District, 3111 Camino Del Rio North, Suite 200, San Diego, CA. 92108-1725 (619) 521-8036 Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval GG Indusionacy Housing Fee required: YES NO (Effective date of Indusionary Housing Ordinance"- May 21, 1993.) Site Plan: G GG JZTG Zoning: G ^GG ZTGG Sfn G Additional 1. Provide a fully dimensioned site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensioned setbacks and existing topographical lines. 2. Provide legal description of property, and assessor's parcel nimiber. 2. 3. 4. Setbacks: Front: Int. Side: Street Side: Rear: Lot coverage: Height: Parking: Required Required Required Required Required Required Spaces Required Guest Spaces Required Shown Shown Shown Shown Shown Shown Shown Shown Comments / ^ Z,.^ . , t cd OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE PLNCK.FRM City of Carlsbad 95169 Fire Department Bureau of Prevention Plan Review: Requirements Category: Building Plan Check Date of Report: Thursday. August 17,1995 Reviewed by: H.JS^ /^^U^A/L^U^ Contact Name Address Deslgn/Bulld 9770 Carroll Center Rd #B City, State San Diego CA 92126 BIdg. Dept. No. 95-1115 Planning No. Job Name Pacific Trinetics Job Address 2675 Loker Ste. or BIdg. No. IS Approved - The item you have submitted for review has been approved. The approval is based on plans; information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifica- tions, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instaictions in this report can result in suspension of pemnit to construct or install improvements. • Disapproved - Please see the attached report of deficiencies. Please make corrections to plans or specifications necessary to indicate compliance with applicable codes and standards. Submit corrected plans and/or specifk^ations to this office for review. For Fire Department Use Only Review 1st 2nd 3rd Other Agency ID CFDJob# 95169 File# 2560 Orion Way • Carisbad, California 92008 • (619)931-2121 TITLE 24 REPORT FOR: PACIFIC TRINETICS—ENV AND HVAC ONLY 2875 LOKER AVE SUITE B CARLSBAD CA PROJECT DESIGNER: DESIGN BUILD 9770 CARROLL CENTER ROAD SUITE B SAN DIEGO CA 92123 (619) 549-8455 REPORT PREPARED BY: DAVID SOSNA DAVID SOSNA, ENERGY CONSULTANT 1637 EAST VALLEY PARKWAY #106 ESCONDIDO, CA 92027 (619) 489-5778 Job Number: PACTRI Date: 8/11/1995 The COMPLY 24 computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential Building Energy Efficiency Standards. >t-§"i^ J r- Table Of Contents for Title 24 Report Cover Page 1 Table of Contents 2 Form ENV-1 Envelope Certificate of Compliance 3 Form ENV-2 Prescriptive Envelope Summary 5 Form MECH-1 Mechanical Certificate of Compliance 9 Form MECH-2 Prescriptive Mechanical Summary 12 Form MECH-3 Mechanical Equipment Summary 14 Form MECH-4 Mechanical Ventilation 15 HVAC Zone Loads Summary 16 CERTIFICATE OF COMPLIANCE (part 1 of 2) ENV-1 page 3 of 17 Project Name: PACIFIC TRINETICS—ENV AND HVAC ONLY Address: 2875 LOKER AVE SUITE B CARLSBAD CA Envelope Designer: DESIGN BUILD Documentation: DAVID SOSNA, ENERGY CONSULTANT Date: 8/11/1995 Building Permit No Checked by / Date COMPLY 24 User 3102 GENERAL INFORMATION Date of Plans: Building Conditioned Floor Area: 3376 sf Building Type: Nonresidential Climate Zone: 7 Phase of Construction: O New Construction O Addition O Alteration Method of Envelope Compliance: Prescriptive - Overall Envelope STATEMENT OF COMPLIANCE This Certificate of Compliance lists the Building features and performance specifications needed to comply with Title 24, Part 6, Chapter 1 and Title 20, Chapter 2, Subchapter 4, Article 1 of the California Code of Regula- tions. This certificate applies only to Building envelope requirements. The Principal Envelope Designer hereby certifies that the proposed build- ing design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed Building has been designed to meet the envelope requirements contained in sections 110, 116 through 118, and 143 or 149 of Title 24, Part 6, Chapter 1. Please check one: O I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a civil engineer or architect. O I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing docu- ments for work that I have contracted to perform. O I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section of the Code to sign this document as the person responsible for its preparation; and for the following reason PRINCIPAL ENVELOPE DESIGNER DESIGN BUILD ^ml^Ljig^lUJO^ <?^6>^£4 (619) 549-8455 (J(Signature) (Lie. #) (Date) ENVELOPE MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures: CERTIFICATE OF COMPLIANCE (part 2 of 2) Project Name: PACIFIC TRINETICS—ENV AND HVAC ONLY Documentation: DAVID SOSNA, ENERGY CONSULTANT ENV-1 page 4 of 17 Date: 8/11/1995 COMPLY 24 User 3102 OPAQUE SURFACES Assembly Name Const Type Location/Comments 6" Concrete Wall None R-11 MtlStud adj uncond Metal R-19 Roof (R.19.2X8.16) Wood Solid Wood Door None Note to Field FENESTRATION Frame Orient Panes Type Exterior Shade OH Glazing Type Right (N) Right (N) Left (S) 1 Metal None 1 Metal None 1 Metal None N Single Clear Default(N) N Single Tint Default(N) N Single Clear Default(N) OVERALL ENVELOPE METHOD Part 1 of 4 Project Name: PACIFIC TRINETICS—ENV AND HVAC ONLY Documentation: DAVID SOSNA, ENERGY CONSULTANT ENV-2 page 5 of 17 Date: 8/11/1995 COMPLY 24 User 3102 0.0 ft X 6 ft = 1222.0 sf X 0.40 = 1222.0 sf X 0.10 = WINDOW AREA TEST A. Display Perimeter B. Gross Exterior Wall Area C. Gross Exterior Wall Area D. Enter Larger of A or B E. Enter Proposed Window Area If E is greater than D or less than C, proceed to for window area adjustment. If not, go to part 2 1. If E is greater than D: D. Maximum Standard Area N/A / 2. If E is less than C: C. Minimum Standard Area N/A / E. Proposed Area N/A E. Proposed Area N/A 0.0 sf Display Area 488.8 sf 40% Area 122.2 sf Min Std Area 488.8 sf Max Std Area 289.0 sf Proposed Area the next calculation of 4. Window Adjustment Factor N/A Window Adjustment Factor N/A SKYLIGHT AREA TEST If Height < 55 ft Standard =5% Atrium Height 0.0 ft If Height >= 55 ft - Standard = 10% A. Gross Exterior Roof Area 3376.0 sf X 0.05 = 168.8 sf Standard Area B. Enter Proposed Skylight Area 0.0 sf Proposed Area If the Proposed Skylight Area is greater than the Standard Skylight Area, proceed to the next calculation for the skylight area adjustment. If not got to part 2 of 4. 1. If Proposed Skylight Area > Standard Skylight Area: Skylight Standard Skylight Area Proposed Skylight Area Adjustment Factor N/A / N/A N/A OVERALL ENVELOPE METHOD Part 2 of 4 Project Name: PACIFIC TRINETICS—ENV AND HVAC ONLY Documentation: DAVID SOSNA, ENERGY CONSULTANT ENV-2 page 6 of 17 Date: 8/11/1995 COMPLY 24 User 3102 OVERALL HEAT LOSS PROPOSED Adj. STANDARD Assembly Name Area HC U -Val UxA Area u -Val UxA 6" Concrete Wall 40. 0 15.4 0 .752 30. 1 40. 0 0 .690 27. 6 R-19 Roof (R.19.2x8.16) 412. 0 2.3 0 .051 21. 1 412. 0 0 .078 32. 1 6" Concrete Wall 130. 0 15.4 0 .752 97. 7 130. 0 0 .690 89. 7 6" Concrete Wall 144. 0 15.4 0 .752 108. 3 144. 0 0 .690 99. 4 R-19 Roof (R.19.2X8.16) 757. 0 2.3 0 .051 38. 8 757. 0 0 .078 59. 0 Single Tint Default(N) 288. 0 N/A 1 .190 342. 7 288. 0 1 .230 354. 2 R-19 Roof (R.19.2X8.16) 265. 0 2.3 0 .051 13. 6 265. 0 0 .078 20. 7 R-11 MtlStud adj uncond 291. 0 1.1 0 .208 60. 5 291. 0 0 .189 55. 0 6" Concrete Wall 188. 0 15.4 0 .752 141. 4 188. 0 0 .690 129. 7 R-19 Roof (R.19.2X8.16) 1329. 0 2.3 0 .051 68. 1 1329. 0 0 .078 103. 7 Single Clear Default(N) 1. 0 N/A 1 .190 1. 2 1. 0 1 .230 1. 2 R-19 Roof (R.19.2x8.16) 238. 0 2.3 0 .051 12. 2 238. 0 0 .078 18. 6 R-11 MtlStud adj uncond 120. 0 1.1 0 .208 24. 9 120. 0 0 .189 22. 7 R-19 Roof (R.19.2x8.16) 375. 0 2.3 0 .051 19. 2 375. 0 0 .078 29. 3 Total 979. 6 Total 1042. 9 ** OVERALL HEAT LOSS COMPLIES PROPOSED UA <= STANDARD UA ** OVERALL ENVELOPE METHOD Part 3 of 4 Project Name: PACIFIC TRINETICS—ENV AND HVAC ONLY Documentation: DAVID SOSNA, ENERGY CONSULTANT ENV-2 page 7 of 17 Date: 8/11/1995 COMPLY 24 User 3102 OVERALL HEAT GAIN Glazing WF PROPOSED Area SC H OHF Total STANDARD Area RSHG Total North South 0.34 288.0 0.72 1.31 1.0 0.94 70.5 288.0 0.94 1.2 1.0 0.71 92.0 0.9 ** OVERALL HEAT GAIN COMPLIES Total 71.7 Total 93.0 PROPOSED HG <= STANDARD HG ** OVERALL ENVELOPE METHOD Part 4 of 4 Project Name: PACIFIC TRINETICS—ENV AND HVAC ONLY Documentation: DAVID SOSNA, ENERGY CONSULTANT ENV-2 page 8 of 17 Date: 8/11/1995 COMPLY 24 User 3102 Window Area Adjustment Calculations Adjust Adjusted Gross Door Window Adjust Window Wall Wall Name Dir Area Area Area Factor Area Area West W 40.0 0.0 1.0000 0.0 40.0 North N 418.0 288.0 1.0000 288.0 130.0 West W 144.0 0.0 1.0000 0.0 144.0 DEMISING—SOUTH S 312.0 20.0 1.0 1.0000 1.0 291.0 West W 188.0 0.0 1.0000 0.0 188.0 DEMISING—SOUTH S 120.0 0.0 1.0000 0.0 120.0 TOTALS 1222.0 20.0 289.0 289.0 913.0 Skylight Area Adjustment Calculations Adjust Adjusted Dir Gross Skylt Adjust Skylt Roof Roof Name Dir Area Area Factor Area Area R-19 Roof H 412.0 0.0 0.0000 0.0 412.0 R-19 Roof H 757.0 0.0 0.0000 0.0 757.0 R-19 Roof H 265.0 0.0 0.0000 0.0 265.0 R-19 Roof H 1329.0 0.0 0.0000 0.0 1329.0 R-19 Roof H 238.0 0.0 0.0000 0.0 238.0 R-19 Roof H 375.0 0.0 0.0000 0.0 375.0 TOTALS 3376.0 0.0 0.0 3376.0 CERTIFICATE OF COMPLIANCE (part 1 of 3) MECH-1 page 9 of 17 Date: 8/11/1995 Project Name: PACIFIC TRINETICS—ENV AND HVAC ONLY Address: 2875 LOKER AVE SUITE B CARLSBAD CA Mechanical Designer: SOUTHERN HEATING Documentation: DAVID SOSNA, ENERGY CONSULTANT Building Permit No Checked by / Date COMPLY 24 User 3102 GENERAL INFORMATION Date of Plans: Building Conditioned Floor Area: 3376 sf Building Type: Nonresidential Climate Zone: 7 Phase of Construction: O New Construction O Addition O Alteration Method of Mechanical Compliance: Prescriptive Proof of Envelope Compliance: O Previous Permit O Compliance Attached STATEMENT OF COMPLIANCE This Certificate of Compliance lists the Building features and performance specifications needed to comply with Title 24, Part 6, Chapter 1 and Title 20, Chapter 2, Subchapter 4, Article 1 of the California Code of Regula- tions. This certificate applies only to Building mechanical requirements. The Principal Mechanical Designer hereby certifies that the proposed build- ing design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed Building has been designed to meet the mechanical requirements contained in sections 110 through 115, 120 through 124, 140 through 142,144 and 145. Please check one: O I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a civil engineer mechanical engineer or architect. I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing docu- ments for work that I have contracted to perform. O I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section of the Code to sign this document as the person responsible for its preparation; and for the following reason: PRINCIPAL MECHANICAL DESIGNER SOUTHERN HEATING (619) 737-0500 '"(Signature) (Lie. #) (bate) ^7A^ MECHANICAL MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures: CERTIFICATE OF COMPLIANCE (part 2 of 3) Project Name: PACIFIC TRINETICS—ENV AND HVAC ONLY Documentation: DAVID SOSNA, ENERGY CONSULTANT MECH-1 page 10 of 17 Date: 8/11/1995 COMPLY 24 User 3102 SYSTEM FEATURES Zone Name Time Control Setback Control Note to Field ZONE 1 None # of Isolation Zonesn/a HP Thermostat Electric Heat Fan Control VAV Min Position Simul. Heat/Cool Heat Supply Reset Cool Supply Reset Ventilation OA Damper Control Economizer Type Outdoor Air CFM Heat Equip Type Make & Model No. Cool Equip Type Make and Model Yes 0.0 KW Constant Volume n/a n/a Constant Temp Constant Temp No Economizer 175 Heat Pump RHEEM RPND048 DX ZONE 2 None n/a Yes 0.0 KW Constant Volume n/a n/a Constant Temp Constant Temp No Economizer 564 Heat Pump RHEEM RPND048 DX Code Tables Time Control S:Prog Switch 0:Occ Sensor M:Man Timer Ventilation B:Air Balance C:OA Cert. M:OA Measure D:Demand Cont N:Natural OA Damper A:Auto G:Gravity CERTIFICATE OF COMPLIANCE (part 3 of 3) Project Name: PACIFIC TRINETICS—ENV AND HVAC ONLY Documentation: DAVID SOSNA, ENERGY CONSULTANT MECH-1 page 11 of 17 Date: 8/11/1995 COMPLY 24 User 3102 DUCT INSULATION System Name Type Duct Location Duct Tape Insul Note to Allowed R-Val Field RHEEM RPND048 RHEEM RPND048 Heating Ducts in Attic Cooling Ducts in Attic Heating Ducts in Attic Cooling Ducts in Attic Y / N Y / N Y / N Y / N 4.2 4.2 4.2 4.2 PIPE INSULATION System Name Domestic Hot Water Pipe Type Insul Required Y / N Note to Field NOTES TO FIELD - For Building Department Use Only MECHANICAL SIZING AND FAN POWER Project Name: PACIFIC TRINETICS—ENV AND HVAC ONLY Documentation: DAVID SOSNA, ENERGY CONSULTANT MECH-2 page 12 of 17 Date: 8/11/1995 COMPLY 24 User 3102 SIZING AND EQUIPMENT SELECTION HVAC Zone Name: Heating System Name: Cooling System Name: System Multiplier: Peak Load Method: Relative Humidity: 1. DESIGN CONDITIONS FOR Carlsbad 2. SIZING SPACES SERVED BY SYSTEM PEAK CORRIDOR—ZONEl OFFICE—ZONE 1 (Jan 12am) (Jan 12am) TOTAL SPACE LOAD Duct Gains & Losses: Ventilation: ( 175 CFM) Return Air Lighting Gain Supply/Return Fan Gain: TOTAL SYSTEM LOAD 3. SELECTION A. Safety/Warmup Factor B. Maximum Adjusted Load C. Installed Equipment Capacity If Line 3-C > Line 3-B, Explain:. Btu/hr 2585 20541 23126 2313 6044 ( 0 31483 1.43 45020 40167 ZONE 1 RHEEM RPND048 COINCIDENT 50 % HEATING 38 F PEAK (Aug 4pm) (Aug 4pm) 175 CFM) COOLING SENSIBLE LATENT 83 F Btu/hr 5246 18553 23799 2380 888 0 0 27067 1.21 32751 39271 67 F Btu/hr 1027 1514 2541 194 2735 9662 FAN POWER CONSUMPTION Fan Description Supply Fan FAN POWER DEMAND No. Sys BHP Efficiency Peak Motor Drive HP Conv Peak Supply Fact Watts CFM 1 X 0.50 / [0.70 X 1.00] = 0.71 X 746 = 533 1750 Totals 0.71 533 1750 533 watts / 1750 cfm = 0.304 watts/cfm MECHANICAL SIZING AND FAN POWER Project Name: PACIFIC TRINETICS—ENV AND HVAC ONLY Documentation: DAVID SOSNA, ENERGY CONSULTANT MECH-2 page 13 of 17 Date: 8/11/1995 COMPLY 24 User 3102' SIZING AND EQUIPMENT SELECTION HVAC Zone Name: Heating System Name: Cooling System Name: System Multiplier: Peak Load Method: Relative Humidity: ZONE 2 RHEEM RPND048 COINCIDENT 50 % HEATING COOLING SENSIBLE LATENT 1. DESIGN CONDITIONS FOR Carlsbad 38 F 83 F 67 F 2. SIZING SPACES SERVED BY SYSTEM PEAK Btu/hr PEAK Btu/hr Btu/hr CORRIDOR—ZONE 2 (Jan 12am) OFFICE—ZONE 2 (Jan 12am) CONFRENCE—ZONE 2 (Jan 12am) LUNCHROOM—ZONE 2 (Jan 12am) WAREHOUSE (Jan 12am) 1044 8922 937 2275 0 (Aug (Aug (Aug (Aug (Aug 4pm) 4pm) 4pm) 4pm) 4pm) 3061 15061 3428 6298 0 662 2658 1224 3414 0 TOTAL SPACE LOAD 13178 27848 7958 Duct Gains & Losses: Ventilation: ( 543 CFM) Return Air Lighting Gain Supply/Return Fan Gain: 1318 18721 ( 0 543 CFM) 2785 2750 0 0 600 TOTAL SYSTEM LOAD 33217 33382 8558 3. SELECTION A. Safety/Warmup Factor B. Maximum Adjusted Load C. Installed Equipment Capacity 1.43 47500 40166 1.21 40393 38518 10771 If Line 3-C > Line 3-B, Explain: FAN POWER CONSUMPTION Fan Description No. Sys BHP Efficiency Peak Conv Peak Supply Motor Drive HP Fact Watts CFM Supply Fan Exhaust Fan 1 X 0.50 / [0.70 X 1.00] = 0.71 X 746 = 533 1750 1 X 0.10 / [0.49 X 1.00] = 0.20 X 746 = 152 200 FAN POWER DEMAND 685 watts / Totals 0.92 685 1750 1750 cfm = 0.391 watts/cfm MECHANICAL EQUIPMENT SUMMARY Project Name: PACIFIC TRINETICS—ENV AND HVAC ONLY Documentation: DAVID SOSNA, ENERGY CONSULTANT MECH-3 page 14 of 17 Date: 8/11/1995 COMPLY 24 User 3102 CENTRAL SYSTEM SUMMARY Sys No System Name No System Type Sys Economizer Type Packaged Heat Pu 2 No Economizer RHEEM RPND048 CENTRAL SYSTEM RATINGS Sys Heating No Type Output Aux KW EFF 0.0 7.10 DX Cooling Type Output Sensible EER SEER 1 Heat Pump 49000 47500 35000 8.50 9.50 CENTRAL FAN SUMMARY Sys No Fan Type Motor Location Supply Fan — CFM BHP 1 Constant Volume Draw-Through 1750 0.50 70 100 Return Fan Mtr Drv Mtr Drv Eff Eff CFM BHP Eff Eff None ZONAL FAN SUMMARY Space Name No CFM Zonal Fan Exhaust Fan Mtr Drv Mtr Drv BHP Eff Eff No CFM BHP Eff Eff CORRIDOR—ZONE 2 None None 200 0.10 49 100 EVAPORATIVE COOLING Sys No Type Return Effectiveness Integrated Air Heat CFM Direct Indir Operation Recovery MISCELLANEOUS MOTORS Sys No Type BHP Mtr Drv Eff Eff MECHANICAL VENTILATION Project Name: PACIFIC TRINETICS—ENV AND HVAC ONLY Documentation: DAVID SOSNA, ENERGY CONSULTANT MECH-4 page 15 of 17 Date: 8/11/1995 COMPLY 24 User 3102 VENTILATION SUMMARY BY SPACE Space Name T Occupancy Floor Area sqft /Occ CFM Min /OCC CFM Tran Design sfer CFM CFM CORRIDOR—ZONEl OFFICE—ZONE 1 CORRIDOR—ZONE 2 OFFICE—ZONE 2 CONFRENCE—ZONE 2 LUNCHROOM—ZONE 2 Corridor/Restr Office Corridor/Restr Office Convention/Con Dining Area 412 200 30. 0 62 62 757 143 21. 5 114 114 265 200 30. 0 40 40 1329 143 21. 5 199 199 238 29 15. 4 126 126 375 29 15. 4 199 199 TOTALS 739 739 Note: If Tailored (T=*), user must document sqft/Occ and/or CFM/Occ values. HVAC ZONE HEATING & COOLING LOAD SUMMARY Project Name: PACIFIC TRINETICS—ENV AND HVAC ONLY Documentation: DAVID SOSNA, ENERGY CONSULTANT page 16 of 17 Date: 8/11/1995 COMPLY 24 User 3102 HVAC ZONE DESCRIPTION HVAC Zone Name: Heating System Name: Cooling System Name: System Multiplier: Fan Schedule: Peak Load Method: Relative Humidity: SPACES IN THIS ZONE CORRIDOR—ZONEl OFFICE—ZONE 1 PEAK (Jan 12am) (Jan 12am) TOTAL SPACE LOAD Duct Gains & Losses: Ventilation: ( 175 CFM) Return Air Lighting Gain Supply/Return Fan Gain: TOTAL SYSTEM LOAD HEATING 2585 20541 23126 2313 6044 ( 0 31483 ZONE 1 RHEEM RPND048 Day Fans STD COINCIDENT 50 % COOLING PEAK SENSIBLE LATENT (Aug 4pm) (Aug 4pm) 175 CFM) 5246 18553 23799 2380 888 0 0 27067 1027 1514 2541 194 2735 SYSTEM OUTPUT AT DESIGN CONDITIONS MAIN HEATING & COOLING SYSTEM 40167 TOTAL SYSTEM OUTPUT 40167 39271 39271 9662 9662 NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment which will heat or cool this zone during the design conditions indicated. These numbers include no safety factor, and the HVAC contractor should oversize by a reasonable margin to account for variations in weather conditions and the pick-up capacity required to bring the zone to temper- ature as a result of a setback thermostat. Those responsible for final equipment selection should note that Sensible and Latent Cooling Loads are indicated to allow for accurate comparison with manufacturer's output data. HVAC ZONE HEATING & COOLING LOAD SUMMARY Project Name: PACIFIC TRINETICS—ENV AND HVAC ONLY Documentation: DAVID SOSNA, ENERGY CONSULTANT page 17 of 17 Date: 8/11/1995 COMPLY 24 User 3102 HVAC ZONE DESCRIPTION HVAC Zone Name: Heating System Name: Cooling System Name: System Multiplier: Fan Schedule: Peak Load Method: Relative Humidity: ZONE 2 RHEEM RPND048 Day Fans STD COINCIDENT 50 % COOLING Ventilation: Return Air Lighting Gain Supply/Return Fan Gain: ( 543 CFM) 18721 ( 543 CFM) 2750 0 0 TOTAL SYSTEM LOAD 33217 SPACES IN THIS ZONE PEAK HEATING PEAK SENSIBLE LATENT CORRIDOR—ZONE 2 (Jan 12am) 1044 (Aug 4pm) 3061 662 OFFICE—ZONE 2 (Jan 12am) 8922 (Aug 4pm) 15061 2658 CONFRENCE—ZONE 2 (Jan 12am) 937 (Aug 4pm) 3428 1224 LUNCHROOM—ZONE 2 (Jan 12am) 2275 (Aug 4pm) 6298 3414 WAREHOUSE (Jan 12am) 0 (Aug 4pm) 0 0 TOTAL SPACE LOAD 13178 27848 7958 Duct Gains & Losses: 1318 2785 600 33382 8558 SYSTEM OUTPUT AT DESIGN CONDITIONS MAIN HEATING & COOLING SYSTEM 40166 TOTAL SYSTEM OUTPUT 40166 38518 38518 10771 10771 NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment which will heat or cool this zone during the design conditions indicated. These numbers include no safety factor, and the HVAC contractor should oversize by a reasonable margin to account for variations in weather conditions and the pick-up capacity required to bring the zone to temper- ature as a result of a setback thermostat. Those responsible for final equipment selection should note that Sensible and Latent Cooling Loads are indicated to allow for accurate comparison with manufacturer's output data. CQ • 3 I ii r lU is 11 10. a. C91 t Si mi -•v vw Vi-" T- Ti- ( Q. X I V Pi « -I r •i I II I ,l*Miiti 111' UJ 1 tu IT I rU I lis ah "'I Iff i , 3 CO J 5^