HomeMy WebLinkAbout2884 Trails Ln; ; CB153199; PermitResidential Permit
Print Date: 01/13/2020
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
2884 Trails Ln
BLDG-Residentia I
1560904100
$439,241.00
1
3.00
TRAILS END
Work Class:
Lot#:
Reference#:
Construction Type:
Bathrooms:
Orig. Plan Check#:
Plan Check#:
Single Family Attached
13
DEV04063
VB
4.50
PC130072
Description: TRAILS END-TYPEl-LOT 13-SF ATTACHED 2781 SF, 523 SF GAR, 445 SF DECK
Applicant: Owner:
4 DESIGN ARCHITECTURE
KENNITH L CHRISS
TRUST THE PEV FAMILY REVOCABLE TRUST
5505 Can cha De Golf
Rancho Santa Fe, CA 92091-4041
760-433-1785
BUILDING PERMIT FEE $2000+
BUILDING PLAN CHECK FEE (BLDG)
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PUBLIC FACILITIES FEES -outside CFD
SB1473 GREEN BUILDING STATE STANDARDS FEE
SDCWA SYSTEM CAPACITY CHARGE 5/8" Displacement
SEWER CONNECTION FEE (General Capacity all areas)
STRONG MOTION-RESIDENTIAL
SWPPP INSPECTION FEE TIER 1-Medium BLDG
TRAFFIC IMPACT Residential Condo Outisde CFD
WATER METER FEE 1" Displacement
WATER SERVICE CONNECTION FEE 5/8" DISPLACEMENT (P)
WATER TREATMENT CAPACITY CHARGE 5/8" Displacement
Total Fees: $32,046.64 Total Payments To Date: $32,046.64
(City of
Carlsbad
Status:
Applied:
Issued:
Permit
Finaled:
Inspector:
Final
Inspection:
Balance Due:
Permit No: CB153199
Closed -Finaled
09/29/2015
12/19/2017
CRenf
1/13/2020 10:46:00A~
$0.00
$1,833.00
$783.10
$66.00
$166.00
$92.00
$182.00
$15,373.44
$18.00
$5,029.00
$934.00
$57.10
$232.00
$2,632.00
$352.00
$4,169.00
$128.00
Please take NOTICE that approval of your project includes the 11lmposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as 11fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
PERMIT INSPECTION HISTORY REPORT (CB153199)
Permit Type: BLDG-Residential Application Date: 09/2912015 Owner: TRUST THE PEV FAMILY
REVOCABLE TRUST
Work Class: Single Family Attached Issue Date: 12/19/2017 Subdivision:
Status: Closed -Finaled Expiration Date: 03/09/2020 Address: 2884 Trails Ln
IVR Number: 709457 Carlsbad, CA
Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date
06/10/2019 06/10/2019 BLDG-16 lnsulatlon 094219-2019 Passed Andy Krogh Complete
06/12/2019 06/12/2019 BLDG-17 Interior 094449-2019 Partial Pass Chris Renfro Reinspection Incomplete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency 1st layer party wa 11s Yes
06/19/2019 06/19/2019 BLDG-82 Drywall, 095040-2019 Passed Chris Renfro Complete
Exterior Lath, Gas
Test, Hot Mop
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-17 Interior Lath-Drywall Yes
BLDG-18 Exterior Lath and Yes
Drywall
BLDG-23 Gas-Test-Repairs Yes
08/08/2019 08/08/2019 BLDG-21 100146-2019 Passed Chris Renfro Complete
Underground/Underf
loor Plumbing
Checklist Item COMMENTS Passed
BLOG-Building Deficiency Backflow underground, ok to backfill Yes
09/10/2019 09/10/2019 BLDG-Electric Meter 103590-2019 Passed Chris Renfro Complete
Release
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
01/13/2020 01/13/2020 BLDG-Final 116079-2020 Passed Chris Renfro Complete
Inspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-Plumbing Final Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLDG-Electrical Final Yes
January 13, 2020 Page 4 of 4
PERMIT INSPECTION HISTORY REPORT (C8153199)
Permit Type: BLDG-Residential Application Date: 09/29/2015 Owner: TRUST THE PEV FAMILY
REVOCABLE TRUST
Work Class: Single Family Attached Issue Date: 12/19/2017 Subdivision:
Status: Closed -Finaled Expiration Date: 03/09/2020 Address: 2884 Trails Ln
IVR Number: 709457
Carlsbad, CA
Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date
05/10/2019 05/10/2019 BLDG-16 Insulation 091498-2019 Partial Pass Tim Frazee Reinspection Incomplete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Insulation and draft stopping at Party walls Yes
and wrap back on ceiling from Party walls
05/14/2019 05/14/2019 BLDG-13 Shear 091732-2019 Partial Pass Paul Burnette Relnspectlon Incomplete
Panels/HD (ok to
wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Party wall hold downs, LTP 4s, Framing OK Yes
to insulate 5/2/19
05116/2019 05116/2019 BLDG-17 Interior 092030-2019 Partial Pass Paul Burnette Re Inspection Incomplete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
05/20/2019 05/20/2019 BLDG-17 Interior 092281-2019 Partial Pass Paul Burnette Relnspectlon Incomplete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
05123/2019 05/23/2019 BLDG-17 Interior 092637-2019 Partial Pass Paul Burnette Reinspection Incomplete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
06/03/2019 06/03/2019 BLDG-84 Rough 093539-2019 Passed Chris Renfro Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
06/07/2019 06/07/2019 BLDG-13 Shear 094142-2019 Partial Pass Andy Krogh Reinspection Incomplete
Panels/HO (ok to
wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Party wall hold downs, L TP 4s, Framing OK Yes
to insulate 5/2/19
BLDG-Building Deficiency Interior shear at party walls Yes
January 13, 2020 Page 3 of 4
PERMIT INSPECTION HISTORY REPORT (CB153199)
Permit Type: BLDG-Residential Application Date: 09/29/2015 Owner:
Work Class: Single Family Attached Issue Date: 12/19/2017 Subdivision:
Status: Closed -Finaled Expiration Date: 03/09/2020 Address:
IVR Number: 709457
Scheduled
Date
Actual Start Date Inspection Type Inspection No.
Checklist Item
BLDG-Building Deficiency
01/25/2019 01/2512019 BLDG-14 0821 86-2019
Frame/Steel/Bolting/
Welding (Decks)
Checklist Item
BLDG-Building Deficiency
02/12/2019 02/12/2019 BLDG-14 083695-2019
Frame/Steel/Bolting/
Welding (Decks)
Checklist Item
BLDG-Building Deficiency
02/19/2019 02/19/2019 BLDG-14 084041-2019
Frame/Steel/Bolting/
Welding (Decks)
Checklist Item
BLDG-Building Deficiency
03/13/2019 03/13/2019 BLDG-14 085955-2019
Frame/Steel/Bolting/
Welding (Decks)
Checklist Item
BLDG•Building Deficiency
04110/2019 04/10/2019 BLDG-13 Shear
Panels/HD (ok to
wrap)
088462-2019
Checklist Item
BLDG·Building Deficiency
04/11/2019 04/11/2019 BLDG-15
Roof/ReRoof (Patio)
088581-2019
Checklist Item
BLDG·Building Deficiency
05/02/2019 05/02/2019 BLDG-13 Shear
Panels/HD (ok to
wrap)
090628-2019
Checklist Item
BLDG·Building Deficiency
January 13, 2020
Inspection Status Primary Inspector
COMMENTS
Footings Check
Partial Pass
COMMENTS
Tim Frazee
Floor sheathing on basement floor
Partial Pass Paul Burnette
COMMENTS
Floor sheathing on basement floor
Passed Tim Frazee
COMMENTS
Nailing on Floor sheathing on basement
floor
Nailing on Floor sheathing on 2nd Floor
Partial Pass Tim Frazee
COMMENTS
3rd floor sheathing OK 3/13/19
Passed Tim Frazee
COMMENTS
Passed Tim Frazee
COMMENTS
Roof sheathing nailing
Partial Pass Tim Frazee
COMMENTS
Party wall hold downs, L TP 4s, Framing OK
to insulate 5/2/19
TRUST THE PEV FAMILY
REVOCABLE TRUST
2884 Trails Ln
Carlsbad, CA
Reinspection Complete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Complete
Passed
Yes
Reinspectlon Incomplete
Passed
Yes
Complete
Passed
Yes
Complete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Page 2 of 4
PERMIT INSPECTION HISTORY REPORT (CB153199)
Permit Type: BLDG-Residential Application Date: 09/29/2015 Owner: TRUST THE PEV FAMILY
REVOCABLE TRUST
Work Class: Single Family Attached Issue Date: 12/19/2017 Subdivision:
Status: Closed -Finaled Expiration Date: 03/09/2020 Address: 2884 Trails Ln
IVR Number: 709457 Carlsbad, CA
Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date
12/20/2017 BLDG-21 044275-2017 Passed Paul Burnette Complete
Underground/U nderf
loor Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
01/0412018 01/0412018 BLDG-11 045043-2018 Partial Pass Paul Burnette Reinspection Incomplete
Foundatlon/Ftg/Pler
s (Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
01/2312018 01123/2018 BLDG-11 046594-2018 Partial Pass Paul Burnette Re inspection Incomplete
Foundatlon/Ftg/Pier
s (Rebar)
Checklist Item COMMENTS Passed
BLOG-Building Deficiency No
02/0512018 02/0512018 BLDG-66 Grout 047840-2018 Passed Tim Frazee Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
02/22/2018 02/22/2018 BLDG-11 049418-2018 Partial Pass Paul Burnette Re inspection Incomplete
Foundatlon/Ftg/Pler
s (Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
03/27/2018 0312712018 BLDG-66 Grout 052865-2018 Partial Pass Paul Burnette Re inspection Incomplete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
04/10/2018 04/10/2018 BLDG-66 Grout 054433-2018 Passed Paul Burnette Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
0611412018 06114/2018 BLDG-11 060803-2018 Passed Paul Burnette Complete
Foundatlon/Ftg/Pler
s (Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
10123/2018 10/23/2018 BLDG-11 073889-2018 Partial Pass Tim Frazee Reinspection Incomplete
Foundatlon/Ftg/Pler
s (Rebar)
January 13, 2020 Page 1 of 4
«~ ~ CITY OF,
CARL:SBAD
RE-~ORD. COPY
CB153199
2884 TRAILS LN Building Division INSPECTION RECORD
0 INSPECTION RECORD CARD WITH APPROVED
TRAILS END-TYPE1-LOT 13-SF ATTACHED2781 SF. 523
SF GAR. 445 SF DECK
PLANS MUST BE KEPT ON THE JOB
0 CALL BEFORE 3:00 pm FOR NEXT WORK DAY INSPECTION
@ FOR BUILDING INSPECTION CALL: 760-602•2725
OR GO TO: www.carlsbadca.goy/BuHdlng AND CLICK ON
'"Request Inspection··
DATE: 12-
DEV04063
PC130072
1560904100
12/14f2017
CB153199
Jf ··YFS" is dH:,dwd below that Divis.ion·!'. ;:ipprovat is requirnd w•or to r(:qucsting a Final Building Inspection. It you have any <1t1estions
please c.ill the ~pplic.1hlc divi5ions at the phone numbers 1novhkd below. After all rcc1uireli apprnvab .ire ~ignetl off .. fax to
7GO-G02 85GO, em<til tu h!dginspections('!;carlsb<Hlca.gov or bring in a COPY of thi~ c,1nl to: -u)J5 F.ir.id.iv Ave" Carlsh;ul.
Required Prior to Requesting Bulldlng Flnal If Checked YES
Planning/Landscape
CM&I {Engineering Inspections)
Fire Prevention
Type of Inspection
CODlc: II BUILDING
#11 FOUNDATION
#12 REINFORCED SIEEL
1168 MASONRY PRE GROUT
.:!!-GROUT □ WALL DRAINS
#10 TILT PANELS
#11 POUR STRIPS
#11 COLUMN FOOTINGS
#14 SUBFRAME □ FLOOR □ CEILING
#15 ROOF SHEATHING
#13 EXT. SHEAR PANELS
#18 INSULATION
#18 EXTERIOR LATH
#17 INTERIOR LATH & DRYWALL
#51 POOL EXCA/SIEEL/BOND/FENCE
□ PL/CO
#21 UNDERGROUND □WASTE □ WTR
#24 TOP OUT □WASTE □WfR
#27 TUB & SHOWER PAN
#23 □ GAS TEST □GAS PIPING
#25 WATER HEATER
#28 SOLAR WATER
#29 FINAL
CODE II STORM WATER
#600 PRE-CONSTRUCTION MffllNG
#603 FOLLOW UP INSPECTION
#605 NOTICE TO CLEAN
#807 WRITTEN WARNING
#809 NOTICE OFVIOLATION
#810 VERBAL WARNING
REV 10/2016
760-944-8463
7 60-438-3891
7~02-4660
Date Inspector
Ins ector
~,
Allow 48 hours
Call before 2 pm
Allow 48 hours
CODE N ELECTRICAL
#31 □ ELECTRIC UNDERGROUND □ UFER
#34 ROU ELECTRIC
#43 HEAT·AIR COND. SYSTEMS
#49 FINAL
#82 ORYWAU,EXTLATH, GAS TES (17,18,23)
#83 ROOF SH EATING, EXT SHEAR (13,15)
#84 FRAME ROUGH COMBO (14,24,34,44)
T-Bar (14,24,34,44)
FINAL OCCUPANCY (19,29,39,49)
A/S UNDERGROUND VISUAL
A/S UNDERGROUND HYDRO
A/S UNDERGROUND FLUSH
A/S OVERHEAD VISUAL
A/S OVERHEAD HYDROSTATIC
A/SFINAL
F/AROUQH,IN
F/AFINAL
FIXED EXTINGUISHING SYSTEM ROUGH-IN
FIXED EXTING SYSIEM HYDROSTATIC TEST
FIXED EXTINGUISHING SYSIEM FINAL
MEDICAL GAS PRESSURE TEST
MEDICAL GAS FINAL
Date Inspector
Date Ins
SEE BACK FOR SPECIAL NOTES
Construction Testing & Engineering, Inc.
Inspection I Testing I Geotechnical· I Environmental & Construction Engineering I Civil Engineering I Surveying
DAILY FIELD REPORT
Client: Pacifica Real Estate Services Inc Job 10-13959T Number:
Job Name: Trails End Residential Subdivision Development Day(s): Monday
Job Location: 3151, 3155 Donna Dr. Carlsbad Ca. Date(s): 4.9.19 2876, 2880, 2884, 2888 Trails End Carlsbad Ca.
Engineer: HTK Structural Engineers LLP
Permit number: CB153136, CB153197, CB153201, CB153200, CB153199, CB153198
Shear-wall Special Inspection
Performed the shear-wall special inspections on the shear-walls
that had fastener spacing at 4" or less per CBC section 1705 at
lot #1, #2, #11, #12, #13 and lot #14 per sheet S4. 0 Basement,
lower floor and main floor, sheet S4.1 upper floor and roof plan.
Verified correct materials, nailing spacing, hold-downs, foundation
connection and shear transfer between floors/roof. All corrections
were performed during the inspections, the installation is in
compliance with the approved plans.
Certification of Compliance: All work, unless otherwise noted, complies with the ap
the California Code of Re ulations Title 24.
NAME: Bill Atwood SIGNATURE:
CERTIFICATION NO 5012754
1441 Montiel Road, Suite 115 I Escondido, CA 92026 I Ph (760) 746-4955 I Fax (760) 746-9806 I www.cte-inc.net
~ GEOCENTRIC
L ,\ :\ fl S L: R \' E Y I l\ C :\ :\ D ~ :\ l' l' 1 '.'..: C
April 5, 2019
To Whom It May Concern:
Subject: Trails End, Donna Drive, Carlsbad
Geocentric Land Surveying performed an as-built field survey on April 4, 2019 and I hereby
certify that the framing on the roof, is as shown on the the following table.
LOT GARAGE
PAD
1 253.97
2 251.97
7 216.97
8 214.97
9 215.47
10 217.47
11 217.47
12 219.47
13 228.97
14 230.97
Sincerely,
Lorne DaPron
PLS 7824
2ND RIDGE RIDGE LINE
FINISH LINE HEIGHT
FLOOR ABOVE PAD
254.64 276.02 22.05
252.64 274.03 22.06
217.64 239.14 22.17
215.64 237.13 22.16
216.14 237.59 22.12
218.14 239.63 22.16
218.14 239.66 22.19
220.14 241.64 22.17
229.64 251.08 22.11
231.64 253.09 22.12
~~15() ~ C .... ·nt:rt Cit:y Pkwy Suire B, F.scon<lido CA 92026
tel: 760.207.78'24 fax: 760.745.7824
\VWw.µpxTntricsLtr\'cy.com
_z:::,.,,;. J!t. -) . ) -.,,. • . , ' ~----'
~E. ,/ J~--/ .. ,., r·· !,_--l-://// :-""
·.·. . . . ,;: . ;,),""-. --. (, fl '. '·-s, .
. .
w.o. 6/) J ;-··_ ::_.
DATE /.L-l.. "7-/ 7
NAME /:2. CJ1...1 Sr>v? ·i
HOURS ______ _
.G._eotechnical • Coastal • Geologic • Environmental
FOOTING TRENCH OBSERVATION SUMMARY
-. _....-I /.
Client Name: l),.;; fl r1 A L/Ji !VC , L l ,:.,_ Project Name: _-...,.,1-7-<-,'-"'·-t""-d"'" .. ...._.1....:/....:r=--.::C-=--..:--J_' .:;;->-=------------="----'=------......... _...=--..a...a.~--=-----""----,
------j C .,--. .• I .I ' ,,-. V . / I < • r J I ·r , 1../ -I y Location/Tract: ---'1:;._.,;ft-:;:.:-,:...,"-'-1.._f"".5__.;_=:-'--·,....:....:::J c....,,.:...__:::1.....::....-·-"-/:-_<-.._J.::...: .... h"".__,,c.::..A:..."..:..--__;::1.. ..... ~i,__ __ ....c.•---'---------------.,
Unit/Phase/Lot(s): ---~..:..✓~-r....;J:,__""""7'-+-/.s;.i?.....,.__~~r ;~{.:::..u ..,.:.·-..:../-....,.//;:...t;;...::Z::......,.1; ____ 1 __ ? I!....'""'-;..:..:.; ______________ _
,t 'I' • /
.,,...?, •. .,.., ,.r / /
Referenced Geotechnical Report(s): .....;.;.0 ----'-"J.:;_n..:..~.;;;;.~., _ _,_A-=c:=-__,,.-1 --=._=·;_f..._-_J.....:....l ___,,:--;r;.;.._,_-......a.;t=_,, _-/_b _________ _ ,,.
Observation Summary
l,/ ,..
il/n .
/_../
ll,, /1 J
'
-,~~,,-:
n k 1
I
/•-'
;1.,,/n
Initials
Date
Initials
Date
Initials
Date
Initials
Date
A representative of GeoSoils, Inc. observed onsite soil and footing trench conditions. Soil conditions
in the trench are generally free of loose soil and debris, non-yielding and uniform, and plumb; and
are in general conformance with those indicated in the geotechnical report.
A representative of GeoSoils, Inc. observed and reviewed footing excavation depth/width. Footing
excavations generally extend to proper depth and bearing strata, and are in general conformance
with recommendations of !he geotechnical report.
A representative of GeoSoils, Inc. reviewed footing setbacks from slope face (if applicable). The
setback was in general accordance with the recommendations of the geotechnical report.
I
Notes to Superintendent/Foreman
3.
4.
Footing excavations should be cleaned of loose debris and thoroughly moistened just prior to placing concrete.
Based on expansion potential of underlying soils, presoaking of soil below slabs may be recommended. Consult
the geotechnical report for presoaking recommendations. We note that clayey so_ils may tak~e~ended
period of time for such, and the contractor should schedule according[#'_.e::' €€~ ~u,I s I" _..,W"""
In the event of a site change subsequent to our footing observation and prior to concrete placement (i.e., heavy
rain, etc.), we should be contacted to perform additional site observations and/or testing.
This memo does not confirm the minimum footing dimension as required by the project structural engineer's
design, if different from the geotechnical report.
Notes to Building Inspector
Soil compaction test results, as well as depth of fill, relative compaction, bearing values, corrosivity, and soil expansion
index test results are contained in the As-Graded Geotechnical or Final Compaction Report provided at the completion
_q grading. /<,/· /'
~~::2_ -'~----·-· ··-
5741 Palmer Way
Carlsbad, CA 92008
(760) 438-3155
1446 E. Chestnut Ave.
Santa Ana, CA 92701
(714) 647-0277
Representative of GeoSoils, Inc.
26590 Madison Ave.
Murrieta, CA 92562
(951) 677-9651
I .
•
W.0. 0&-,35 -C
DATE.-=--1_-...;7-:__---'-l~S~_
NAME f\,{ I k.£ ...$t:::r--.V\-
HOURS_~-i-__ . o ___ _
Geotechnical • Coastal • Geologic • Environmental
FOOTING TRENCH OBSERVATION SUMMARY
Client Name: Dr) N NA Project Name: /fl. 14 \ i_ S 13= Nb
Location/Tract: Tn.. v;,1 L 5 r::;:.ND CAt'<.LSf,1\.D C. I 61--\ -I Lf
Unit/Phase/Lot(s): _..;..L-.....:o:;_., r'---""'-:s __ \c....,/_-z....:;:.;...--,--.....::5::::..' ..!../'--'1-t......;-. ___._.-c::;.,;;.._.:,/-=l ~ __ ...;(.__1 ----'-~-)-=-----------, /
Referenced Geotechnical Report{s): -=D...:.rt..!..·.:...;r-E:=:...:..::I)'--__._/ =o_-...... 3a::..:...I -----'1_,_.__,.____b=-_-__._6.__---=-l...;;:b:;..._ ______ _
I
Observation Summary
iM5 Initials
l / 7../ l9, Date
A representative of GeoSoils, Inc. observed onsite soil and footing trench conditions. Soil conditions
in the trench are generally free of loose soil and debris, non-yielding and uniform, and plumb; and
are in general conformance with those indicated in the geotechnical report.
;MS Initials A representative of GeoSoils, Inc. observed and reviewed footing excavation depth/width. Footing
excavations generally extend to proper depth and bearing strata, and are in general conformance
with recommendations of the geotechnical report.
I !z./1 B Date
t'v\ -S Initials A representative of GeoSoils, Inc. reviewed footing setbacks from slope face (if applicable). The
setback was in general accordance with the recommendations of the geotechnical report. 1 /-2/ 18 Date
vV 5 Initials Pt:.RF on....,..r:c b 5£f:L.Gcc, , ,.., f>nD f~ IN{,, ON \.)N{)Sll.'SU"'I d vn u H Tr"2€ N(l-t~:i-. I ..,,<..,1 C '<
Pt1<o(S\,-..> <, I.N ht (.V', le...f T rh,,,, 'T;"2..e NC.Hes 8?Ac. k 1-, l.-l.. 1 s R,1:; L "2-ril/l T"'i c. OV"-' e ,,3:.:.. T j t I z. I I R Date
Ar->.!) S1.nrA ('.L\::. Fon... -r,+rc: .i;:-,,...,Tiaev->Ot.:.r> u.SC
Notes to Superintendent/Foreman
3 .
4.
Footing excavations should be cleaned of loose debris and thoroughly moistened just prior to placing concrete.
Based on expansion potential of underlying soils, presoaking of soil below slabs maybe recommended. Consult
the geotechnical report for presoaking recommendations. We note that clayey soils may take an extended
period of time for such, and the contractor should schedule accordingly. ¾"-/<6 e p Mc 1 5 r ~
In the event of a site change subsequent to our footing observation and prior to concrete placement (i.e., heavy
rain, etc.), we should be contacted to perform additional site observations and/or testing.
This memo does not confirm the minimum footing dimension as required by the project structural engineer's
design, if different from the geotechnical report.
Notes to Building Inspector
Soil compaction test results, as well as depth of fill, relative compaction, bearing values, corrosivity, and soil expansion
index test results are contained in the As-Graded Geotechnical or Final Compaction Report provided at the completion
of grading.
5741 Palmer Way
Carlsbad, CA 92008
1446 E. Chestnut Ave.
Santa Ana, CA 92701
Representative ~Gfu-SOils, Inc.
26590 Madison Ave.
Murrieta, CA 92562
January 3, 2018
To Whom It May Concern:
GEOCENTRIC
LA\\; D S l. RV 1-: \· 1 N (;. AN D ~i AP f' 1 '.\ <.;
Subject: Trails End, Donna Drive, Carlsbad
Geocentric Land Surveying performed an as-built field survey on January 3, 2018 and found the
lower level building forms for buildings numbers 1 through 14 to substantially conform to the line
and grade as shown on the approved Precise Grading Plan. As such conforms to all building
setbacks.
Sincerely,
Lorne DaPron
PLS 7824 No. 7824
Construction Testing & Engineering, Inc.
Inspection I Testing I Geotechnical I Environmental & Construction Engineering I Civil Engineering I Surveying
INSPECTION REPORT PAGE OF
8 I..! ? ,7 ;::• f".·
7 8 ,6· 1 Q8o 2.8 ·7, _._..-_,_,6 ~ t _,___ / ✓ -. ,
CTE JOB NO. /0-l i't S'9 I
REPORT NO.
PROJECT NAME T (I]., Al ( S E_, V O f2.eS/t_J tf/,..11'/ µ, l INSPECTION MA TE RIAL IDENTIFICATION
CONC. MIX NO. & lb/in2 ADDRESS C /4/)i SAA Q t/ I .:.l. A <~t.:-/)/2.. fl.
/)Q/',J N ,-.\ 1)(2 G?"it?.L 513,A 0
ENGINEER
CONTRACTOR
OTHER
INSPECTION DATE
PLAN FILE/OTHER ___________ _
BLDG. PERMIT/OTHER <J?7l ·i 3 1 '/ 8 -Ce,! 1..,-3 Zot
□
g
□
□
□
□
□
□
□
CONCRETE
REINF. STEEL
MASONRY
PT CONCRETE
FIELD WELDING
SHOP WELDING
BATCH PLANT
EXP. ANCHOR
OTHER
GROUT MIX NO. & lb/in2
MORT AR TYPE & lb/in2
REINF. STEEL GR./SIZE At_; .. t,; rUi ,..:;~)
STRUCTURAL STEEL
HIGH-STRENGTH BOLT _____ _
MASONRY BLOCK
MATERIAL SAMPLING
0 CONCRETE 0 MORTAR 0 GROUT 0 FIREPROOFING O MASONRY BLOCK
0 REINFORCING STEEL 0 STRUCTURAL STEEL 0 BOLTS O OTHER -------
INSPECTIONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS
PLEASE NOTE ANY RE-INSPECTION, TESTING, OR OTHER PROJECT ISSUES .
. r-:.-20 r .,,,1 r.--~. A-T UN 1 : ct I L'.p T 5 / f-I 4 .111,--.,,; , rl ·5 c-,,., 1·H 'if: ,:i ~"" T , "•i 4: u $ /J,.: 1.f 11'4 TiJr-/,t. 5
/!lc;,,(f~/Q<-,,~/ ,1//:-:t:[ S'Y.r> ,C.!ut110urAu //)/ .. -,'/, I ,Fr,,l}_AJtA3ey,,-,1 ,v k1f4Ll -~(<11 .> . .
I l '-'; _d !//. 1.21,.,; r&t} ,1;/i././("-r· : r/ f.;. :--.; <:,.,.;.,··;; {;,:_ '/ ,; :/)_A ;r.,,1: ,·/ I
Certification of Compliance: All work, unless otherwise noted, complies with applicable codes and the approved plans and specifications.
~.._ ________________________________________ ..
PRINTED NAME
CERTIFICATION NO.
/
,/ /l ..... .p""',
SIGNATURE ~/.=1/:.::..<--'...;:.~=V:..,;,,a-,;:,.;,_---.::.~.....=-~"""~9,.-;P'-' _· --
1441 Montiel Road, Suite 115 I Escondido, CA 92026 Ph (760) 746-4955 I Fax (760) 746-9806 I www.cte-inc.net
Construction Testing & Engineering, Inc.
Inspection I Testing I Geotechnical I Environmental & Construclion Engineering I Civil Engineering I Surveying
INSPECTION REPORT PAGE-~-Qf 1
GTE JOB NO. 10-13959T
REPORT NO.
PROJECT NAME Trails end residential INSPECTION MATERIAL IDENTIFICATION
ADDRESS Carlsbad village and Donna dr. □ CONCRETE CONG. MIX NO. & lb/in2
121 REINF. STEEL GROUT MIX NO. & lb/in2
ARCHITECT _4-'-='D""ese,ig.,n'-------------□ MASONRY MORTAR TYPE & lb/in'
ENGINEER ---'H'--'-T-'--'K..,_ __________ _ □ P.T. CONCRETE REINF. STEEL GR/SIZE Grade #60
CONTRACTOR Pacifica -'--'==----------□ FIELD WELDING STRUCTURAL STEEL
OTHER □ SHOP WELDING HIGH-STRENGTH BOLT
INSPECTION DATE □ BATCH PtANT MASONRY BLOCK
PLAN FILE/OTHER ---'6"----"13-=20-c1c.=8 _______ _ □ EXP.ANCHOR OTHER
BLDG. PERMIT/OTHER _b,,,ecclo"-'w,__ ______ _ □ OTHER
MATERIAL SAMPLING
□
□
CONCRETE □
REINFORCING STEEL
MORTAR □ GROUT □ FIREPROOFING D
OTHER
MASONRY BLOCK
□ STRUCTURAL STEEL . □ BOLTS □
INSPECTIONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS
PLEASE NOTE ANY RE-INSPECTION, TESTING OR OTHER PROJECT ISSUES.
Weather partial clouds 70's/ Locations lots 11, 12, 13, 14 and exterior piers permits CB153198/CB 153199/ CB153200 and CB153201/
Observed placement of reinforcing footings and slab on grade these locations as per plans and specifications/Details shown page S4.0
Reinforcing tied in place and were needed placed on concrete chairs to maintain position and clearance/ Footings cleaned of excess
dirt and debris to maintain clearance from soil/ these locations ready for concrete placement/< end >
Certification of Compliance: All work, unless otherwise noted, complies with applicable codes and the approved plans and specifications.
PRINTED NAME ---'M"'-l"-'ke--...,_-Ki"-'n9.,ec:..ryL-_______ _
CERTIFICATION NO. ICC 5258871/ SD 1001
1441 Montiel Road, Suite 115 I Escondido, CA 92026 I Ph (760) 746-4955 f Fax (760) 746-9806 I www.cte-inc.net
~ GEOCENTRIC
LAN [) S l' RV EV ING AND \! A PP IN(,
June 12, 2018
To Whom It May Concern:
Subject: Trails End, Donna Drive, Carlsbad
Geocentric Land Surveying performed an as-built field survey on June 12, 2018 and found the
garage/second floor forms for buildings numbered 11 through 14 to substantially conform to the
line and grade as shown on the approved Precise Grading Plan. As such conforms to all
building setbacks.
Sincerely,
Lorne DaPron
PLS 7824 No. 7824
0 150 .'l Centre C,cy l'kwy Suite ll, Escondido CA 9.,026
tel: 760.207.7824 fax: 760745.7824
\li/\11.rvv·,gcocenlric~urvey.com
31110
231.61
LOT 14
2nd FF=231.64
BASEMENT
FF~211.24
PAD=2Hl:15¥.l ., 2 .64
LOT 13
2nd /F=229.64
flASLMENT
FF=209.24
PAD 020857
---,.-----31111 231.61
GAl~AGE
PAD=
230.97
GAHACE
/JAD=
228.97
PLAN 1
31115 229.64 'r-J--------J: 31114 ~-------.1 229.62 x31116 x31117
229.63 229.62
r
_______ .2;x 31119
220.17
X 31118
220.17
31120 220.16 ,.....--,.-----31121 LOT 12 220.15
2nd FF=220.14
BASEMENT
ff =1~-1~:i
PAD= 1!$ !ii?!'
PLAN 1
2n}~{J}fuJ~4
13ASLMENT
rr=197.74
PADcc,197.07
PLAN 1
GARAGf:
PAD·'' 219.47
GARAGE
PAD=
217.1I
31125
218.17
31127 218.16~~----~311m
....
_______ .) 218.17
X 31128 218.17 X 31129 218.16
GARAGE
/JAD= )1741
. -------------~~
LOT 14
2nd FF= 231. 64
BASEMENT
FF=211.24
PAD=210.57
·' 1
LOT/_
2nd FT=229.64
BASEMENT
FF=209.24
PAD .... 20857
PLAN 1
GAl?AGE
ii'~~? 2m1>
~tJAtl
228.97
X 078 2 .94
0076
X 31.01
co X 28.94
073 ,_,__ ____ xy28.93
LOT 12
2nd FF=220.14
BASEMENT
FF=199.74
PA0=199.07
PLAN 1
LOT 11
2nd FF =218. 14
l3ASEMENI
F/=19/.74
PAD•197.07
PLAN 1
G~E xr~sc
219.47
~ 217.47
0067
X 19.52
X 3 069 9.50
X 0070 17.51
X 3 72
,....>------11 7.49
GARAGE PAD=
21747 e,'\
... WO /~~ ~--1·i., .:...-"'
• ·-· .... ~ ......... ---•...--,;J ......... , .... , ---~ -
DATE._-=h~/1~/~/~_~ __ _
NAME. __ '~r~-c:=~----
HOURS __ ~2 ___ _
Geotechnical • Coastal • Geologic • Environmental
FOOTING TRENCH OBSERVATION SUMMARY
Client Name: .· )7Al.l/,4 l'e IW:. l {.f!,, ---Project Name: . Ii 411,,,-; /i,v1>
Location/Tract: _ ..... ,=~<1=,a~"'c-t-A,,....f' ..... -..... 1..:;;,e;...-:·"""'/)_.___.t/_·..._f __ V ___ ___,. ____________________ _
I J . j Unit/Phase/Lot(s): l o T-~ I I r; AlrJ6 l~r:s I ,l t./-
1 /
t£li-,'l {/.
'
I I
Referenced Geotechnical Report{s): ...;.'...a4;....'...;..:;_./._, _.1..,_:A._,~•::.....f'r?""'"""'~:xa...a., .... ' ..... £:4--:J""'l:..:!;2).,_·=--lo,.../_~ li..,a/,'-'-1..._1 ....,.../.i..:.lt,=rJ={)-(,'"'"/i'"":o...,./2"""1/---'t, _______ _ l I I , I
Observation Summary
r_;;;. Initials
/4 /1 lll'Date
I I
A representative of GeoSoils, Inc. observed onsite soil and footing trench conditions. Soil conditions
in the trench are generally free of loose soil and debris, non-yielding and uniform, and plumb; and
are in general conformance with those indicated in the geotechnical report.
di~ Initials
I, I 1/2 ~·Date .
I I
A representative ofGeoSoils, Inc. observed and reviewed footing excavation depth/width. Footing
excavations generally extend to proper depth and bearing strata, and are in general conformance
with r~commendations of !he geotechnical report.
~ Initials ~A representative of GeoSoils, Inc. reviewed footing setbacks from slope face (if applicable). The
I, ir fl (Date 11 setback was in general accordance with the recommendations of tbe geotechnical report. . -----,'--✓-;-_ .. * /--:a,4 Tl«' 1 1~C..5 ,&-a.c, k?T<, //,;:,:. J/~ ~ tt)~ T o ('DtJC-.. _t~Mlt/llNUf.?1? 1 'n, F~?ll c-
/.;;&. Initials "' _r~.µe,;(,ti.b {{1:.-,[E,V/l)Pr, f ~·.c:,;oe.,. //? \J ~TlC-t,.,<.... U-0/J-:,--:T;;,t,dr.::-,10 f..f. /::-rt:,1'; ;.,., f'/c;C.S ?i?/:: iJ;:;,T/tf
~/1 /Jf Date A .,__..Nt7T_-::v ;oH'le IC;'f-'~""~ _T 7/1!~ -1m1t:--n..,,,.,c., ,N I 11~{1:.. ?~7/1~ /$-C-
'I ,::::. -Of· 'IC-,---' L,.,VI-,' '(11'?1 ->1"1 •
Notes to Superintendent/Foreman
1. Footing excavations should be cleaned of loose debris and thoroughly moistened just prior to placing concrete.
2. Based on expansion potential of underlying soil~, presoaking of soil below slabs may be recommended. Consult
the geotechnical report for presoaking recommendations. We note that clayey soils may take an extended
period of time for such, and the contractor should schedule accordingly. /·ft'e/l 1/;t?/ST
3. In the event of a site change subsequent to our footing observation and prior to concrete placement (i.e., heavy
rain, etc.), v-re should be contacted to perform additional site observations and/or testing. ~
4. This memo does not confirm the minimum footing dimension as required by the project structural engineer's
design, if different from the geotechnical report.
Notes fo Bulldlng Inspector
Soil compaction test results, as weU-a-s depth of fill, ,re(~tive compaction, bearing values, c.orrosivity, and soil expansion
index test results are contained i9-Jtte As-Grac;led Geotechnical or Final Compaction Report provided at the completion
of grading. · · _.·· ...:..----; . ) -----
/ --f / .. __ ,,/ ~--., 1/
5741 Palmer Way
Carlsbad, CA 92008
(760) 438-3155
1446 E. Chestnut Ave.
Santa Ana, CA 92701
(714) 647-0277
Representative of Ge~Soiis, Inc.
\,
26590 Madison Ave.
Murrieta, CA 92562
(951 ) 677-9651