Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2888 LOKER AVE E; 112; CB122724; Permit
. City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 02-27-2013 Commercial/Industrial Permit Permit No: CB122724 Building Inspection Request Line (760) 602-2725 Job Address: 2888 LOKER AV EAST CBADSt: 112 Permit Type: TI Sub Type: INDUST Status: ISSUED Parcel No: 2090832200 Lot #: 0 Applied: 12/20/2012 Valuation: $140,090.00 Construction Type: 5B Entered By: JMA Occupancy Group: Reference # Plan Approved: 02/27/2013 Issued: 02/27/2013 Inspect Area . . Plan Check #: Project Title: GSW CONSULTING: 3,774 SF OFF TO OFFICE TI COMBINING STIES. 111 & 112 Applicant: . Owner: BRIANT HOWES GLOBAL CARLSBAD.! L L C #212 r \C/O GLOBAL CRES 2888 LOKER Mi EAST 7 . 2888 LOKER AVE 'E #212 N CARLSBAD CA 92010 / \ "-) v--CARLSBAD CA 92010 760-634-1919 7 ........- Building Permit / ,.. ..."-.',I $856.34 Meter Size Add'I Building Permit Fee/ ,\ •.' $0.00 Add'I Red. Water Con. Fe-) ./\ \ $0.00 Plan Check / / ' \. ,/ $599.44 Meter Fee "\ "\ $0.00 Add'I Building Permit Fee ) 1' $0.00 SDCWA Fee J \ $0.00 Plan Check Discount / / / . $0.00 CFD Payoff Fee \ "--' $0.00 Strong Motion Fee $29.42 PFF (3105540) . \ \. .) ' $0.00 Park Fee I $0.00 PFF (4305540) \ \ ', \ $0.00 LFM Fee -. / \$0.00 License Tax (3104193) $0.00 Bridge Fee ' ,"\ $0.00 License Tax (4304193) 7 - $0.00 BTD #2 Fee ( , $0.00 Traffic Impact Fee (3105541) • J j $0.00 BTD#3 Fee $0.00 Traffic Impact Fee (4305541)\ \..._/ . $0.00 Renewal Fee ,$0.00\ PLUMBING TOTAL _/ $52.00 Add'I Renewal Fee ('$0.00 \ ELECTRICAL TOTAL. ' . $41.00 Other Building Fee \ j$0:00 \ MECHANICAL-TOTAL / J / $0.00 Pot. Water Con. Fee $0.00--,,Master Drainage Fee -/ / / $0.00 Meter Size \ \ '\\ "SewerFee,- / / $0.00. Add'I Pot. Water Con.Fee - $0.00, Redev Parking Fee' / / $0.00 Red. Water Con. Fee /$o.00 AdditiônaIFees- / $0.00 Green Bldg Stands (5B1473) Fee '\ ,$4.00 HMP Fee_r 1 / . ?? Fire Expedidted Plan Review •. '\ $0.00 COGr!ee BIdg Standards Plan Chk / ?? .7 TOTAL PERMIT FEES' "''-. / $1,582.20 1• - / \ . , . .. ,•'•\ •, ,. Total Fees $1 582 20\Total Payments To Date $1 582 20 '"BIa'nce Due: $0.00 FINALPOV% Inspector: Date: / ' 1 1 3 - Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your rtght to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any DHEALTH DHAZMATIAPCD Building Permit Application Plan Check No.03 2• 1635 Faraday Ave., Carlsbad, CA 92008 Est. Value ' 1(41) 0 q0. Ph: 760-602-2719 Fax: 760-602-8558 email: building@carlsbadca.gov Plan Ck. Deposit www.carlsbadca.gov Date 1 a... I 2- 11 '—iswppp.. JOB ADDRESS : - SUITE#/SPACE#/UNIT# APN 2888LOKERAVENUEEAST 111&112 209 - 083 - 22 - 00 ST/PROJECT a LOT # PHASE # J# OF 1. UNITS iS BEDROOMS iS BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE I 0CC GROUP GSW CONSULTING GR0LJ DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) 3,774 SQUARE FOOT OFFICE SPACE REGENERATION S TENANT IMPROVEMENT MODIFICATIONS S .EXISTING USE PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE AIR CONDITIONING IFIRESPRINKLERS GENERALOFFICE GEN. OFFICE YES NO YES—]NOE YESENO APPLICANT NAME (Primary Contact) BRIANT HOWES APPLICANT NAME (Secondary Contact) MITCH AULD ADDRESS ADDRESS 2888 LOKER AVENUE EAST, SUITE 212 2888 LOKER AVENUE EAST, SUITE 212 CITY .. .. ... ..... STATE •.. ZIP . CITY, STATE ... ZIP CARLSBAD . CA 92010 CARLSBAD .-.-:CA i. 92010 PHONE FAX . PHONE FAX 760-634-1919 760-634-2914 760-295-6939 760-634-2914 EMAIL . EMAIL bhowes@global-cres.com auld@citymark-global.com PROPERTY OWNER NAME CONTRACTOR BUS. NAME I GLOBAL CARLSBAD I, LLC t-z.o r 1LC.HkZOOWNER-BUILDER 'sr. ADDRESS .. ADDRESS 2888-LOKERAVENUEEAST,SU1TE212 2!4 J6PvjTt.E -t. 3T€t oo CITY . STATE ZIP CITY STATE ZIP CARLSBAD CA 92010 5Prr' PHONE FAX . PHONE FAX 760-634-1919 760-634-2914 EMAIL . . EMAIL .. ___________________________ ARCH/DESIGNER NAME ADDRESS ST TE LIC it STAT LiC.# CLASS CITY BUS. LiCe (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve demolish or repair any structure, prior to its issuanq'ejiso reduires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section , 7000 of Division 3 of the Business and Professions Code} or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (55001). Workers' Compensation Declaration: I hereby affirm under penally of perjury one of the following declarations: [J I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain woilers'co nsation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co.-..\) fY- t4,rT_— : Policy No. '(t," r.,UCvO?,I€, I2..( Expiration Date ( 1 This section need not be completed if the pe it for one dred dollars ($100) or less. [:]Certificate of Exemption: I certify that i e pert nnance f the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure rkers' mpensa' n c verage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, da s as p ided r In action 3706 of the Labor code, Interest and attorney's fees. CONTRACTOR SIGNATURE 0 AGENT DATE I.. I hereby affirm that lam exempt from Contractor's License Law for the following reason: [2] I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). [J I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). [] I am exempt under Section . :. Business and Professions Code for this reason: I personally plan to provide the major labor and materials for construction of the proposed property improvement. EYes —]No I (have! have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name address! phone! contractors' license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name! address phone contractors' license number): I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name! address! phone! type of work): ..€S"PROPERTY OWNER SIGNATURE I7IAGENT DATE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: DPLANNING DENGINEERING EJBUILDING LJFIRE ®@iaaa• o®® ®ai Is the applicant or future building occupant required to submit abusiness plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Yes No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Yes No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 07001 W()O(i@ 021 I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lenders Name Lenders Address O? Oc?O®t2 I certifythatl have read the application and state thatthe above Information Iscorrectandthatthe Infomiation onthe plans Isaccunta. I agreeto comptywtth all Cityortilnancesand State laws relatingto building construction. I hereby authorize representative of the C of Ca ad to enter upon the above mentioned property for inspeon purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS COS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA An OSHA permit s required forex ton over 5' 'dee a lition or construction of structures over 3 stones in height EXPIRATION: Every permit issued by the B '---'Official u erth provis sof this Code shall expire by limitation and become nut and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit orifth ing orwo rized b such permits suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). ..'APPLICANT'S SIGNATURE DATE STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. Fax (760) 602-8560, Email buildinci@carlsbadca.aov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. (Office Use Only) Inspection List L- Permit#: CB122724 Type: TI INDUST GSW CONSULTING: 3,774 SF OFF TO OFFICE TI COMBINING STES. Ill & 11 Date Inspection Item InspectorAct Comments 04/01/2013 89 Final COmbo PD AP 03/29/2013 89 Final Combo - RI COF 03/28/2013 152 Final Bldg Inspection - Fire CWON AP 03/12/2013 31 Underground/Conduit-Wirin PD AP 03/07/2013 17 Interior Lath/Drywall PD AP 03/07/2013 24 Rough/Topout - PD AP 03/06/2013 14 Frame/Steel/Bolting/Weldin PD AP 03/06/2013 34 Rough Electric PD AP r 9(cr"— 7i ,-\ cITY OF: CARLSBAD INSPECTION RECORD Building Division ll INSPECTJON RECORD CARD WITH APPROVED PLANS MI.JSTBEKEPTONTHEJOB ll CALL BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION Rl FOR BUILDING INSPECTION CALL. 760-602-2725 OR GO TO: www.Carlsbadca.gev/Building AND CLICK ON "Request lflsppctlon" DATE: CB122724 2888 LOKERAV EAST 112 GSW CONSULTING: 3,774 SF OFF TO OFFICE TI COMBINING STES. 111 & 112 TI INDUST Lot#: BRIANT HOWES re e ik Ls -. c risJ4 RI: CORD COPY IF YES' IS CHECKED BELOW THAT DIVISION'S APPROVAL IS REQUIRED IF YOU HAVE ANY QUESTIONS PLEASE CALL THE APPLICABLE DIVISIONS ALL REQUIRED APPROVALS ARE SIGNED OFF- FAX TO 760-602-8560. OR BRING IN A COPY OF THIS CARD TO: 1635 FARADAY AVE.. CARLSBAD, REACHED AT 760-602-2700 BETWEEN 7:30 AM - 8:00 AM THE DAY Imi— Required for Building Final If Checked YES PRIOR TO AT THE EMAIL CA OF YOUR 'fl IMrc. REQUESTING A FINAL BUILDING INSPECTION. PHONE NUMBERS PROVIDED BELOW. AFTER TO BLDGINSPECTIONS@CARLSBADCA.GOV 92008. BUILDING INSPECTORS CAN BE INSPECTION. 1172,111111 Planning I Landscape 760-944-8463 Allow 48 hours IFAIM 'CM&I (Engineering Inspectlons) 76G-438-3891 Call before 2 pm Type of Inspection #11 FOUNDATION I Date I Inspector I Type of Inspection #31JICTRICUNDERGROUND DUFER Date ppector #12 REINFORCEDSTEEL #34 ROUGH ELECTRIC - 3 '•i '7'7___ #66 MASONRYPRE GROUT #33 El ELECTRIC.SERVICE El TEMPORARY DGROLJT DWALLDRAINS #35 PHOTOVOLTAIC #10 TJLTPANELS #39 FINAL #11 POUR STRIPS #11 COLUMN FOOTINGS #41 UNDERGROUND DUCTS& PIPING #14 SUBFRAME 0 FLOOR 0 CEILING #44 0 DUCT& PLENUM El REF. PIPING #15 ROOF SHEATHING #43 HEAT-AIR COND. SYSTEMS #13 EXT. SHEAR PANELS #49 FINAL #16 INSULATION #18 EXTERIORLATH . #81 UNDERGROUND (11,12,21,31) #17 INTERIOR LATH & DRYWALL 3-7 -15 - fg7'' #82 DRYWALL,EXT LATH, GAS TES (17, 18,23) #51 POOL E)(CWSTEEV BOND/ FENCE #8340OF SHEATING, EXT SHEAR (13,15) #55 PREPLASTER 0 #84 FRAME ROUGH COMBO (14,24,34,44) #19 FINAL 3/?$//3 #89 FINAL OCCUPANCY (19,29,39,49) Inspector. JWtUJI:1I1[c #22 0 SEWER& BL/CO 0 P1,/CO Date Inspector Date I:1 #21 UNDERGROUND OWASTE 0 MR _____ #24 TOPOUT 0WASTE DWTR 3 1.j 3 /"! 1.' ___ 7A/ S UNDERGROUND VISUAL #27 TUB&SIIOWERPAN .SUNDERGROUNDHYDRO #23 DGASTEST OGASPIPING SUNDERGROUNDFLUSH #25 WATER NEATER - A/SOVERHEAD VISUAL __________ ,1.7&t') ____________ #28 SOLAR WATER A/S OVERHEAD HYDROSTATIC q #29 FINAL A/S ANAL MIN IF I #600 PRE-CONSTRUCTION MEETING F/A ROUGH-IN . F/A ANAL I #603 FOLLOW UP INSPECTION FIXED EXTINGUISHING SYSTEM ROUGH-IN #605 NOTICE TO CLEAN - FIXED OIliNG SYSTEM HYDROSTATIC TEST #607 WRITTENWARNING FIXED EX11NGUISHING SYSTEM FINAL #609 NOTICE 07 VIOLATION MEDICAL GAS PRESSURE TEST #610 VERBALWARNING MEDICALGASFJNAL REV 10/2012 . SEE BACK FOR SPECIAL NOTES l( Section 5416. Health and Safety Code, State of California There shall be not less than one water closet for each 20 employees or fractional part thereof working at a construction job site. The water closet shall consist of a patented chemical type toilet. For the purpose of this section the term construction site shall mean the location on which actual construction of a building is in progress. (C) A violation of this section shall constitute a misdemeanor. All construction or work for which a permit is required shall be subject to inspection and all such construction or work shall remain accessible and exposed for inspection purposes until approved by the inspector. Work shall not be done beyond the point indicated in each successive inspection without first obtaining the approval of the inspector. DATE ADDITIONAL NOTES, 14 T13 rw4i7s. /Cc 7t11- .7. l , S- -pro , ,, ''-'- k- - LA / ECEIVED MAR 282013 CITY OF CARLSBAD BUILDING DIVISION EsGil Corporation In Partners/lip with government for Bui1?uing Safety DATE: 2/21/13 U =N T U JURISDICTION: City of Carlsbad . U PLAN REVIEWER U FILE PLAN CHECK NO.: 12-2724 SET: II .. PROJECT ADDRESS: 2888 Loker Ave East Suite 111 & 112 V PROJECT NAME: Global Cres - TI The plans transmitted herewith have been corrected where necessary and substantially comply ';' with the jurisdiction's codes. . The plans transmitted herewith will substantially comply with the juriédiction's building codes when minor deficiencies identified in the remarks below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list' and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. El The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant * contact person The applicant's copy of the check list has been sent to LII. EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: . Telephone #: Date contacted: (by: ) Email: Fax #: Mail Telephone Fax In Person REMARKS: Applicaht to add notes in red on sheets A-3.0, A-5.0, M-1.0, P-1 .O, and E-1.0 to the City held sets. . By: Doug Moody . Enclosures: . -• . . ,. . EsGil Corporation -.' LI GA LI EJ LI Pc 2/14/13 1 9320 Chesapeake Drive Suite 208 • San Diego California 92123 • (858) 560-1468, • Fax (858) 560-1576 EsGil Corporation In cPartnership with government for cBui(ding Safety DATE: 1/3/13 0 PPLICANT 7JURIS. JURISDICTION: City of Carlsbad '0 PLAN REVIEWER 0 FILE PLAN CHECK NO.: 12-2724 SET: I PROJECT ADDRESS: 2888 Loker Ave East Suite 111 & 112 PROJECT NAME: Global Cres - TI LII The plans transmitted herewith have been corrected where necessary-and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list - and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck: The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: 'Global Cres I Briant Howes 2888 Loker Ave East Suite 112, Carlsbad CA 92010 • 'EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Briant Howes Telephone #: 760-634-1919 Date contacted: (by: ) Email: bhowesglobal-cres.com Fax #: 760-634-2914 Mail Telephone Fax In Person. LII REMARKS: • . By Doug Moody Enclosures EsGil Corporation - El GA El EJ. El PC 12/24/12 - 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858)560-1576 City of Carlsbad 12-2724 1/3/13 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 12-2724 JURISDICTION: City of Carlsbad OCCUPANCY: B USE: Office TYPE OF CONSTRUCTION: Unknown ACTUAL AREA: 3774sf ALLOWABLE FLOOR AREA: STORIES: Unknown HEIGHT: SPRINKLERS?: Unknown REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 12/20/12 DATE INITIAL PLAN REVIEW COMPLETED: 1/3/13 FOREWORD (PLEASE READ): OCCUPANT LOAD: Unknown DATE PLANS RECEIVED BY ESGIL CORPORATION: 12/24/12 PLAN REVIEWER: Doug Moody This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2010 CBC, which adopts the 2009 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2009 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad 12-2724 1/3/13 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. Generally the plans are incomplete and a thorough plan check can not be done, the following list is a general list only and corrections may follow. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. California Business and Professions Code. 2. Provide a Building Code Data Legend on the Title Sheet. Include the following code information for each building proposed: Occupancy Classification (s) Description of Use Type of Construction Sprinklers: Yes or No Stories Floor Area Occupant Load 3. Please provide a statement on the Title Sheet of the plans to show compliance with the current Codes. The following are the correct current Codes: The 2010 edition of the California Building Code (CBC) adopts the 2009 International Building Code (IBC) and the 2010 California Amendments. The 2010 edition of the California Electrical Code (CEC) adopts the 2008 National Electrical Code (NEC) and the 2008 California Amendments. The 2010 edition of the, California Mechanical Code (CIVIC) adopts the 2009 Uniform Mechanical Code (UMC) and the 2009 California Amendments. The 2010 edition of the California Plumbing Code (CPC) adopts the 2009 Uniform Plumbing Code (UPC) and the 2009 California Amendments. City of Carlsbad 12-2724 1/3/13 The 2010 edition of the California Fire Code (CFC) adopts the 2009 Uniform Fire Code (UFC) and the 2007 California Amendments. The 2008 edition of the California Energy Efficiency Standards 4. Provide the names, addresses and telephone numbers of the owner and the responsible design professionals on the Title Sheet. Sec. 107.2. 5. Provide a fully dimensioned floor plan showing the size and use of all rooms or areas within the space being improved or altered. Draw the plans to scale and indicate the scale on the plan. Sec. A106.1.1. 6. Please provide a door schedule; indicate the type of hardware and reference the doors on the floor plan. 7. Please provide a wall legend, indicate on the plans the wall type and reference the appropriate construction details. 8. Provide a section view of all new interior partitions. Show: Type, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate "to be ICC approved". Method of attaching top and bottom plates to structure. (NOTE: Top of partition must be secured to roof or floor framing, unless suspended ceiling has been designed for partition lateral load). Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing. 9. Please provide a section view of all new interior glazed partitions. Show: Please provide the listing and installation information of the glass partitions. Specify manufacturer and approval number or indicate "to be ICC approved!I. Method of attaching top and bottom plates to structure. Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing 10. Glazing in the following locations should be of safety glazing material in accordance with Section 2406.3 g) Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position. And where the bottom exposed edge of the glazing is less than 60 inches above the walking surface .11. Please provide a reflective ceiling plan. • • 12. Please provide notes on the plans to show the suspended ceilings in Seismic Design Categories D, E & F comply with ASCE 7-05 Section 13.5.6.2.1 as follows: S . a) All ceilings shall use a Heavy Duty T-bar grid system City of Carlsbad 12-2724 1/3/13 b) The width of the perimeter supporting closure angle shall be not less than 2 inches. C) In each orthogonal horizontal direction, one end of the ceiling grid shall be attached to the closure angle. The other end in eah horizontal direction shall have a %" clearance from the wall and shall rest upon and be free to slide on a closure angle or a listed assembly. Ceiling areas over 1,000 ft.2 must have horizontal restraint wires (typically restraint would consist of four 12 gauge wires splayed 900 to each other and sloped 450 to the horizontal, spaced 12" o.c.). Ceilings without rigid bracing must have 2" oversize trim rings for sprinklers and other ceiling penetrations. It appears the lighting system is to be altered, if so please provide complete plans. Please provide the required energy compliance forms. The LTG forms - shall be signed and imprinted on the plans. Please revise the plans to show the mandatory measures required for the alteration to the lighting system. The relocated lighting fixtures and new lighting controls must comply with lighting control requirements of Sections 119, 130, 131 and 134 of the Energy Standards. Occupancy sensors are required for the following room types: Offices 250 - square feet and smaller, multipurpose rooms less than 1,000 square feet, and classrooms and conference rooms of any size. Please add where appropriate. Section 131. Please provide panel schedules, indicate new and existing loads. Please indicate on the plans the location of the electrical panel and detail the required working clearance. Please indicate if the mechanical system will be altered. If so please provide complete plans. Please provide the required MECH forms to show energy compliance. The MECH forms shall be signed and imprinted to the plans. When new rooms or spaces are constructed and the existing mechanical system is not to be altered other than relocation of existing duct work; please note or show mechanical ventilation will be provided capable of supplying the minimum rate of outside air required per minute per occupant as shown in Table 4-1 of the UMC. Provide complete plumbing plans, including: - Complete drain, waste and vent plans. Provide complete water line sizing and developed pipe lengths. UPC Section 610.0 Show water heater size, type and location on plans. UPC, Section 501.0 City of Carlsbad 12-2724 1/3/13 Note : When alterations, structural repairs or modifications or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the requirements for new buildings, per Section 11 34B.2. These requirements apply as follows: The area of specific alteration, repair or addition must comply as "new" construction. A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features. C) Existing sanitary facilities that serve the remodeled area must be shown to comply with all accessibility features. 20. Show on the site plan the complying disabled accessible path of travel from the disabled accessible parking spaces to the primary entrance of the tenant space. Please provide detailed plans of the path of travel, indicate slope and width, any pedestrian ramps, curb ramps, walks, handrails, provide dimensioned parking stall details etc. 21. It is unclear from the plans if the restrooms servicing the tenant improvement are disabled accessible, please provide a dimensioned restroom plans showing the restroom to be accessible compliant. 22. Revise plans, or door schedules, to show that every required passage door has ~32" clear width, per Section 113313.2. 23. Where a pair of doors is utilized, at least one of the doors shall provide a clear, unobstructed opening width of 32 inches, per Section 113313.2.3. 1. 24. Show or note that all hand-activated door opening hardware meets the following requirements, per Section 1133B.2.5.2: Latching, or locking, doors in a path of travel are operated with a single effort by lever type hardware, by panic bars, push-pull activating bars, or other hardware designed to provide passage without requiring the ability to grasp the opening hardware. Is to be centered ~30" but :544" above floor. 25. Please revise the plans to show the non-commercial kitchenette sink to provide the following: A clear floor space at least 30"x 48" shall be provided for forward approach. The clear space shall extend a maximum of 19" underneath the sink. The accessible sink shall be a maximum of 6 1/2" deep. The sink shall be mounted with the counter or rim no higher than 34" Knee clearance that is at least 27" high, 30" side and 19" underneath the sink shall be provided. Hot water and drain shall be insulated. There shall be no sharp or abrasive surfaces under sinks. City of Carlsbad 12-2724 1/3/13 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes Ll No U The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. City of Carlsbad 12-2724 1/3/13 (DO NOT PAY— THIS IS NOT AN INVOICEJ VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: 12-2724 PREPARED BY: Doug Moody DATE: 1/3/13 * BUILDING ADDRESS: 2888 Loker Ave East Suite 111 & 112 BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: Unknown BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) TI 3774 37.12 140,091 Air Conditioning Fire Sprinklers 'TOTAL VALUE 1 140,091 'Junsdiction Code Icb IBY Ordinance 'Bldg. Perm Fee by Ord,an I $856.341 Plan Check Fee by Ordinance V 0 - $556.621 Type of Review Complete Review • • Structural Only - .. . Repetibve Fee Other - Repeats Hourly Hr. © * , EsGil Fee - I • Comments Sheet of 1 - ' S macvalue.doc + 'I - . PLAN CHECK - Community& Economic . Development Department CITY OF REVIEW <KOW . 163.5 Faraday Avenue iZARLSDJ4%D A TRANSMITTAL' Carlsbad CA 92008 www.carisbadca.gov DATE: 12/31/12 PROJECT NAME: Mammoth Professional Building' - PROJECT ID: PIP 05-14 PLAN CHECK NO CBI 2-2724 SET#: I ADDRESS: 2888 Loker Avenue East APN: 209-083-22 VALUATION: $140,090 . . . - You may have corrections from one oçmore of the divisions listed in the table below ,This plan check review transmittal is to notify you of clearance by: LAND DEVELOPMENT ENGINEERING DIVISION Final Inspection by the Construction & Inspection Division is required: Yes fl 'No EXI - For status from' a division not marked below, please call 760-602-2719 -This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to:'- PLANNING 7606024610 t H Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.gov H, Gina, Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.gov LAND DEVELOPMENT ENG.: . ' -FIRE PREVENTION.: 760-6022750 760-602 4665k I. H Kathleen Lawrence Greg Ryan 760-602-2741 S 760-602-4663' Kathleen.Lawrence@carlsbadca.gov Gregory.Ryan@carlsbadca.gov Linda Ontiveros Cindy Wong 760-602-2773 ' F.]760-602-4662 Linda.Ontiverós@cárlsbadca.gov Cynthia.Wong@carisbad ca.gov Ej Dominic Fieri L_J • ,760-602-4664 Dominic.Fieri@carIsbadca.gov Remarks: Feed as office per C8060639 -- NO ADDITIONAL IMPACT FEES 14411> Land Development Engineering BUILDING PLANCHECK Development Services 'CITY O F CHECKLIST 1635 Faraday Avenue CARLSBAD QUICK-CHECK/APPROVAL ENGINEERING Plan Check for CB122724 Date: 12/31/12 2888 Loker Avenue East 209-083-22 Project Address: APN: Project Description: 3,774sf office tenant improvement Valuation: $140,090 ENGINEERING Contact: Linda Ontiveros Email: Iinda.ontiveros@carlsbadca.gov Phone: 760602-2773 Fax: '760-602-1052 RESIDENTIAL iJ TENANT IMPROVEMENT E RESIDENTIAL ADDITION MINOR . LI PLAZA CAMINO REAL (<$20,000.00) LI CARLSBAD PREMIER OUTLETS LI COMPLETE OFFICE BUILDING F-1 OTHER: . S .. I OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT BY DATE 12/31/12 REMARKS: Fee 'd. as office per CB060639 -- NO ADDITIONAL IMPACT FEES 4t I E36 . Page 1 of 1 ' REV 4/30/11 £ £ - • ••- •, PLANNING DIVISION Development Services BUILDING PLAN CHECK Planning Division - . aradayAvenue i T V 0 F A 1635 F(760) 602-4610 CARLSBAD P-29 0 - .• 0, ,_'_ DATE: 12-20-12 PROJECT NAME:' PROJECT ID: - -. PLAN CHECK NO: CB 12-2724 SET#: I ADDRESS: 2888 Loker Av E.APN: 209083-22-00 ' This plan check review IS complete and has been APPROVED by the Planning Division By Chris Sexton A Final Inspection by the Planning Division is required F. I Yes Z No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit Resubmitted plans should include corrections from all divisions This plan check review is NOT COMPLETE Items missing or incorrect are listed on the attached checklist Please resubmit amended plans as required Plan Check APPROVAL has been sent to bhowes@global-cres corn For questions or clarifications on the attached checklist please contact the following reviewer as marked PLANNING - •---'.:. .: .--"(' ENGINEERING , :-.--, FIRE PREVENTION 760602-4610 7606022750 7606024665 - ,t t• - t Chris Sexton - = Kathleen Lawrence " Greg Ryan' - 760-602-4624 * '• - 760-602-2741 ' 760-602-4663 Chris.Sexton@carlsbadca.gov -. 0 Kathleen.Lawrence@carlsbadca.gov Gregory.Ryan@carlsbadca.gov Gina Ruiz Linda Ontiveros Cindy Wong 760-602-4675 - 760-602-2773 0 760-602-4662 - - Gina.Ruiz@carlsbadca.gov -' Linda.Ontiveros@carlsbadca.gov CynthiaWonE@carIsbadca.gov Dominic Fieri / * 7606024664 . Dominic.Fieri@carlsbadca.gov BUILDI NG DEPT". /i. PLAN CHECK CcrnmIbiti& Economic : \.')V II , DevIopmerit Department CITY 0 F '' W WV 1635 Faraday Avenue .0 A DI CD A D TRANSMITTAL 1 Carlsbad CA 92008 t%F\ LJOI www.carlsbadca.gov DATE: 01/20/2013 PROJECT NAME: GLOBAL PROF BUILDING PROJECT ID: CB122724 PLAN CHECK NO: I SET#: I ADDRESS 2888 LOKER AV EAST STES: 111 & 112 APN: This plan check review is complete and has been APPROVED by the FIRE Division • By:GR A Final Inspection by the FIRE Division is required Z Yes F-1 No This plan check review is NOT COMPLETE. Items missing orincorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be requii'ed prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked: r•-"•yi it • PLANNING ' ENGINEERING FIRE PREVENTION 7606024610 7606022750 I '7606024665 - • • :.• - - ..............:'. • •.. •_ _______ •.: -• - Chris Sexton Kathleen Lawrence . Greg Ryan 760-602-4624 - 760-602-2741 - 760-602-4663 Chris.Sexton@carisbadca.gov Kathieen.Lawrence@carisbadca.gov Gregorv.Ryan@carisbadca.gov Gina Ruiz Linda Ontiveros • Cindy Wong . 760-602-4675 .• 760-602-2773 760-602-4662 Gina.Ruiz@carisbadca.gov . Linda.Ontiveros@carisbadca.gov Cvnthia.Wonp@carisbadca.gov F-1 F-1 • . Dominic Fieri • - • 760-602-4664 I . Dominic.Fieri@carisbadca.gov BUILDING DP Carlsbad Fire Department . S copy Plan Review Requirements Category. TI , II\TDUST Date of Report: 01-20-2013 . Reviewed by: Name: BRIANT HOWES. Address: 2888 LOKER AV EAST #212 . CARLSBAD CA - 92010 Permit # CB122724 Job Name: GSW CONSULTING: 3,774 SF OFF Job Address: 2888 LOKER AV EAST CBAD St: 112. S Please review carefully all comments attached. CITY OF CARLSBAD FIRE DEPARTMENT - APPROVED: S. THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW. Entry: 01120/2013 By: GR Action: AP S -S * • I • • 4 . .