Loading...
HomeMy WebLinkAbout2891 Brentwood Ct; ; CBR2018-2708; PermitCcityaf Carlsbad Residential Permit Print Date: 10/23/2018 Permit No: CBR2018-2708 Job Address: 2891 Brentwood Ct Perm it Type: BLDG-Residential Parcel No: 1S63102600 Valuation: $0.00 Occupancy Group: # Dwelling Units: Bedrooms: Project Title: Description: REPtACE FAU & A/C PLUMBING, ELECTRICAL, AND MECHANICAL PERMIT Total Fees: $17S.OO Work Class: P/M/E Lot#: Reference #: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Owner: TRUST BAME RICHARD K SEPARATE PROPERTY TRUST 04-25-16 2891 Brentwood Ct CARLSBAD, CA 92008 Total Payments To Date: $175.00 Status: Applied: Issued: Permit Finaled: Inspector: Final Inspection: Contractor: WEST COAST APPLIANCES 12S6 Fayette St EL CAJON, CA 92020-1511 619-S57-0446 Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 6602D(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLV to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Closed -Finaled 10/04/2018 10/04/2018 10/23/2018 2:26:lOPM $175.00 $0.00 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602·2700 I 760-602-8560 f I www.carlsbadca.gov Building Permit Application Plan Check No.Cf:R:2.0IX~-J :J()}( - 1635 Faraday Ave., Carlsbad, CA 92008 Est. Value 760-602-2717 I 2718 / 2719 Plan Ck. Deposit Fax 760-602-8558 www.carlsbadca.gov Date ,o--L\-l~ I ,-w~"' · ~ww, •~• • ""'~- JOB ADDRESS SUfTc#/SPACE#/UNIT# 2891 BRENTWOOD CT IAPN 156 -310 -26 -00 CT/PROJECT # I LOT# I PHASE# 1 # OF UNl~S r BEDR;MS #BATHROOMS rENANT BUSINESS MAME -------_________ [~s~;~E I oc~~~~~ 2 DESCRIPTION -OF WORK: Include Square Feet of Affected Area(s) REPLACEMENT OF FAU & AC 4 TON 2271 SQFT EXISTING USE I PROPOSED USE I GARAGE ISF) PATIOS (SF) I DECKS (SF) FIREPLACE I AIR CONDITIONING I FIRE SPRINKLERS YES(]# NCO YEs[{)NoD YESONoD CONTACT NAME (II Different Fom Ap1Jllc1Jnt) SYNDIE PICH APPLICANT NAME ADDRESS ADDRESS 1256 FAYETTE ST . --------·--·· ... ---------------· CITY STATE ZIP CITY STATE ZIP EL CAJON CA 92020 PHONE I FAX PHONE I FAX 619-557-0446 619-448-3708 EMAIL EMAIL westcoastheatcool@.gmail.com PROPERTY OWNER NAME RICHARD BAME CONTRACTOR BUS. NAME WEST COAST APPLIANCE SERVICE INC. f---·-· ,-----------· --· -·---------ADDRESS ADDRESS 2891 BRENTWOOD CT 1256 FAYETTE ST CITY STATE ZIP CITY STATE ZIP CARLSBAD CA 92008 EL CAJON CA 92020 PHONE I FAX PHONE I FAX 530-321-1033 619-557-0446 619-448-3708 EMAIL EMAIL westcoastheatcool@.gmail.com ARCH/DESIO NER NAME & ADDRESS I STATE uc_ # STATE LIC.# lccio. C20 ICITYBUHIC.1211147 810930 !Sec-7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair anl structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he Is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commendmg with Section 7000 of Division 3 of the B_usmess and Professions Code} or !hat he is exem~t therefrom, and the basis for the alleged exemption. Any violation of Section 1031-5 by any applicant for a permit subJects the applicant to a c1v1I penalty of not more than five hundred dollars {$500])_ Workers' Compensation Dedaration: I hereby affirm under penalty of perjury one or tile following dec/araffons· 0 I have and will maintain a certincate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued, [Z] I have and will maintain workers' compensation, as re(lulred bv Section 3700 of the Labor Code. for the performance of the work for wti1ch this permit is issued. My wol1<ers' compensa~on insurance earner and policy number are: Insurance Co STATE FUND Policy No. 9225515-18 Expiration Date ""'' ~section need not be completed if the perm~ is for one hundred dollars ($100) or less, LJ certlflcate of Exemption: I certfy that in the performance of tne work for which this permit is issued, I shall not empfoy any person in any manner so as lo become subiect to the Workers· Compensation Laws 01 Cal~omia, WARNING: Failure to secure workers' compensation coverage is unlawful, an shall subject an employer to criminal penahies and civil fines up lo one hundred thousand dollars 1&100,000), in addition lo the cost or compensation, damages as provided for in Section 3706 of the Labo code, intarest and attorney's fees. ,g CONTRACTOR SIGNATURE I hereby affirm that! am exempt Imm Contractor~ License Law for the fo!Jowmg reason: • • • I, as owner of the property or my employees with wages as lheir sole compensation, will do the work and the struc1ure is nal intended or offered for sale (Sec, 7044, Business and Pmfessions Code: The Contractor's License Law does not apply to an owner of property who builds or impmves thereon, and who does such wor1< himser or through his own em!)loyees, provld~ that such improvements are not intended or offered tor sale, If, however, the building or improvement is sold within one year of completion, the owner-builder will have the bun:len of proving that he did nol build or improve for lhe purpose of sale), I, as owner.or lhe property, am exclusively contracting with licensed contractors lo construct the project (Sec. 7044, Business a,id Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to lhe Contractor's License Law). I am e~empt under Sec~on _____ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement Oves 0No 2. I !have I have not) sigMd an application for a building permit for lhe proposed work. 3. t have contracted with the !allowing person (firm) to provide the proposed construction !include name address I phone I contractors' license number): 4, I plan to provide portions of the wol1<, but l have hired the !ollowlng person to coordinate, supervise and provide the major work (include name I address I phone I contractors' license number): 5, I will provkle some of lhe work, but I have contracted (hired) the following persons lo provide lhe work indicated (include name I address I phone I type of work]: 6$ PROPERTY OWNER SIGNATURE •AGENT DATE ----. ·------------- Is lhe applicant or future bwlding occupant required to submit a businesSJ!!i!!l, acutely hazardous materials registration fomi or risk management and prevenUon program under Seclions 25505, 25533 or 25534 of the Presley•Tarmer Hazardous Substance Account Act? D Yes LJNo Is tl1e applicant or future building occupant required to obtain a pennit from lhe air pollution control district or ai[..9.!jality management district? OYes D No Is lhe facility to be conS1ructed wilhin 1,000 feet of the outer boundary of a school site? Oves LJNo IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POUUTION CONTROL DISTRICT. I cel1ifylhat I have read the appllcation and state that the above information Is correct and that the lnfonnation on the plans is acctJoo, I agree to oomply'M\11 all City ordlnanoesand State laws relating to building construction. I hereby authorize represenlati"l of the Otyof Gartsbad to entei-uprn the above mentioned J:foperlyfe< inspection pu[Jl)SeS. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY Cf CARLSBAD AGAINST All LIABILITIES, JUDGMENTS, COSTS AND EXPENSES 'M--IICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA An OSHA perm~ is required for excavatkms over 5'0' deep and dernolnion e< crnstruclion of structures over 3 stories ,n height. EXPIRATION: E"lry perrnn issued by the Building Ollk:ial under the pr01,isions of this e shall e~pre by limitation and become null and void if lhe building e< work authoozed by such pennn is not wmmenced within 180 days from the dale of such pennil or If the tl.Jilding e<work authorized by such permil suspended or abandoned at any time after the work is commenced IC< a penod ct 180 days (Section 106.4A Unifonn Building Code). _g APPLICANT'S SIGNATURE DATE 10/4/18 -------------------- PERMIT INSPECTION HISTORY REPORT (CBR2018-2708) Permit Type: BLDG-Residential Application Date: 1010412018 Owner: TRUST BAME RICHARD K SEPARATE PROPERTY TRUST 04-25-16 Work Class: P/M/E Issue Date: 10/04/2018 Subdivision: CARLSBAD TCT#77-02 UNIT#01 Status: Closed -Finaled Expiration Date: 04/22/2019 Address: 2891 Brentwood Ct Carlsbad, CA 92008-1163 IVR Number: 14404 Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Re Inspection Complete Date Start Date 10/23/2018 10123/2018 BLOG-43 Air 073928-2018 Passed Andy Krogh Complete CondJFurnace Set BLDG-Final 073927-2018 Passed Andy Krogh Complete Inspection Checklist Item COMMENTS Passed BLDG-Mechanical Final Yes October 23, 2018 Page 1 of 1 . S,i::-E OF CAU'ORN!A AL TERA TIONS ~ HVAC CcC-CF1 R .. 4,~ T.Q3-E '.R,;;•,;;,id ,}S,,1A) f C::RTlFiC.."'TE OF COl'vlPUANCE .A':era,io1;s -1-!V.il.C CZ 1, 3 to 7 and l6 (formerly CF-lR-ALT-HVAO (Page 1 of li 1 Site Address: Enforcement Agency: I Date Prepared: Permit#: i 2891 BRENTWOOD CT ENCINITAS l 10/4/18 I } i i I New: Oucfng_. Plr!nurns, Uneser I Cordit:oned i Equipment Type I Equipment Efficiencv Required R-vaiue l Floer Area (sq ~) Tt1ermos-::2~ I I ! C Evaporator Coil ~AFUE ' ! 0 R-5 (CZ 1,.3-7) Ducts i Se:ve d "JV ~ '/St~ ,11 10 Setback JO ?sckaged Svstem i ___ COP I l· ;• Spiit Sys:em 6 Condensing Unit ~SEER i Cl R-81 (CZ 15) Ducts 2271 sq 't Nf not o!re-1dv ! ' ; HSPF C R-6 10/i CZ'5) i'lenums j ;:,resert, tnust fr F'Jrnace ----' L:neset ---EER i D R-5 or R7.S Uneset3 ; be :r:stal.leo) HERS VERIFICATION SUMMARY tnstailer determines work to oe completed and matches to one of the options belcw. At perrn:t 2pplkation this form is allowed to be fii!ed out by har.d. Fo< final inspection ail forms ;;ire to be registered (no hard filled forms a!lowed) a~d a coov left o:; site. O l. HVAC Changeout/Repair I Required Compliance Documents to be left on site for Fina!: Can lndude new ducting Ail Equipment, I CF!R-.AL 7-02-E Condenser Ur.it, Evaporator Coil, I CF2R: h,1ECH-G'l., TvlEC:--i~2Q .. HER3 Air Hardier /Furnace i CF3R: MECH-20-HERS Installer Requirement: Duct leakage (::__13¾ cc, '.S10% re o\JtSide, or se,I ail acce$sible leaksl Exempted from duct leakage ~astirg ,f; Ol. Duct system registGred 'Nith HERS provider as pr~v1ousiy sealed, or C 2. "'.'he:2 is less than 40 ,inea' feet of duct in unc:ncitionea space, or C 3. Existing duct systems are ~onstruc,ed, in,u!ated or sealed with asbestos 1'ist m,;n\Jfactwe date of building f -~-T- CJ 2. New HVAC System [ Required Compliance Documents to be feft on site for F-lnal: All new equipment and A!I New Ductsl ! CF1R-AL T-02-E 0'2RNECH-Cl .. MECH-20-Hi.;fl.S, ',1ECH•22·HERS, \,lECH-(23 or 24)-HERS l CF3H-i'vlECH-2C-HERS, iv;ECH-22-!-'ERS. i>,IECH·(23 o, 24)·HER52 lr.s~afler Requirement: D·.ct leakage:; 6%. Fan Efficacy (.58vV/CFM}. Alr ;;ow:,. 350 G'M/ton (or 5:andards Table 150.0-C ! :J Jiternat!ve) C 3. All New Ducts with Replaee.ment l Required Compliance Documents to be !eft on site for Final: lndudes replacing or ,mta:!i11g All New ! CF1R-ALHl2-E .· Duct.st and one or rrore of the following: / CF:l.R-MECH-01, MECi-'-2G-HERS, rvlECH-(23 or 24)-HERS Condenser Unit, Evaporator Coil, Furnace i CF3R-MECH-l0-HERS,. i\di:CH-(23 or 24j·HERS installer Requirement: D\Jct leakage~ 6%, Air Flow~ 350 cn,1/tcn (or Standards ,ab1e 150.0-C / O ;ilterrat1vei 0 Exemp!ed fror-i duct !eakage testing i existing duct systems are constructed, 'ns;__,dated or sealed 1-'vith a.sbesto.s, 04 New Ducting over 40 feet Required Compliance Document5 to be ieft on site for Flnal: Adding or replacing due,:~ 1n unconditioned CFlR-ALT-02-E CF2R: rv1EC-l-2C··h'ERS sp;,;ce but less ~han ~ii Ne,.., D"cts' I CF3R: !\1ECH-20-HERS installer Required to: Duct leakage t_l5% or, .'.:,.10% to outside, or seal all accessible ieaks) 0 Exempted from duct leakage testing I ex,1,ting duct systems are ccnst-ucted, nsulated or sealed with asbestos. 1 All new duct,l"g R-8 req:Jirtld when more :han 40 ft :nstalied and R-6 when less tnan 40 ft instai!ed. This includes in walls, between fiocr, etc. 'A New Du~t system 1s wne11 the duct system is constructed of at least 75 oercent ~e•,,., due: materiai, anc up to 25 percent 'Tlay consist of reused parts fro1'1 the dwelli:ig units existing dwct system (e.g., registers, grilles, boots, air ~and!er, p!enums .. duct material. 'R·S {l" thick insu'atJon) for iinesets 1 • and less. R-7.5 (t5·' thrc:k insula~icn} for ifnzsets over 1 :rch. Mr.st mfg wiil ~eqtke Suctio~ !lne Diameter with insuiat,on as the foilcwing :J..5-2T-2¾", 2.5-3T-2%", 3.5 to 4T-2%", ST·4½'' ' . ' ~ Contractor (Documentation Authors /Respons1bfe Designers Oed;aratwn ,)tatement) i certify the following under penalty of perjury, under the !;iw.~ of the 5:ate of Cailfo··•1;a; 3. 4. 5. The information provided on this Cartifkate of Compliance ,5 true and s::orre(r. i am e1igibie unoer Division 3 of the Califcrn,a Busiress arc Professi0n;; Code to accep, re,pons1bility fc: t,'e information ,J" this :iocu01ent. That tt,e er-ergy features and performance specifications for the desig:1 ,der:i,fed Jn ~his Certificate of Comoi'ance conform t:: :he ,equirements of Title 24, Parts 1 and 6 cf the Caf,fornia Code of Regulations (Cm}. That the energy •eah:res and performance speci·f:catic.1s, material:;, ccmponents. -3r~d mariufactured devices fer the butidirg de.sig~i J~ system deslgn identified on this Certificate of Compliance conform to the reo~ireme~ts O' Titie 24, Part 1 and Part 6 ct the CCR. T'e building design feature, or sy~tem design features ideritif:ed .Jn thi, Certificate of Compliance are :onsistent wlth the informatio,~ pro,;ided on other apoiii;ab!e compiiance dace.mer.ts, worksheets. cafculaf1ons. p:ans and specificiltions subm:tted :o ::-,e enforce:ne":t a encv for appmvai with th:s buildin !----_;;;;:,;::.._;;;.;__.;_;-=""--'------'-_;...;_;;_.;___-"'r'----,---'-,-=-~...,..-+-----------.--:----::--:-------r--c------••,--··-~ q,e_~Cjor.sibi-e Oe&igrie-~ .. tame: o~t~ 51groo jl,_~~ PODKOl_HURNl~Q\L .... -.J-------"---'---101~~-----L~.10_93_0 __ , ~0,,,.,,,0 , ~T COAST APPLIANCE ~dore;;, :,1,"scate/Z'p: , ;s!.,,n,, SERVICE INC I 1256 FAYETTE ST EL CAJQN..CA 92020, _!619-557_-0~4~4~6 ___ _ For assistance or questions regarding the Energy Standards, contact the Energy Hotline at: 1-8-00-772•3300 i j t I