HomeMy WebLinkAbout2904 CAMINO SERBAL; ; CBR2018-2301; Permit{city of Carlsbad Residential Permit Print Date: 02/12/2019 Permit No: CBR2018-2301 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: 2904 Camino Serbal BLDG-Residential 2552830600 $3,551.04 Work Class: Lot#: Reference#: Construction Type: Bathrooms: Orig. Plan Check#: Patio Status: Applied: Issued: Permit Finaled: Inspector: Closed -Finaled 09/05/2018 09/25/2018 TFraz Plan Check#: Final Inspection: 2/12/2019 9:53:22AM Project Title: Description: GILES: 288 SF PATIO COVER (CITY STANDARDS)/ GAS AND ELECTRIC FOR BBQ & FIREPIT Owner: Contractor: TRUST JOSHEE-GILES FAMILYTRUST 2904 Camino Serbal RIVERS LANDSCAPE CONSTRUCTION BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) CARLSBAD, CA 92009 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIOENTIAL Total Fees: $196.46 Total Payments To Date: $196.46 1175 Industrial Ave, Ste M Escondido, CA 92029-1431 760-504-4091 Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. $0.00 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov $61.74 $43.22 $41.DO $49.00 $1.00 $0.50 (cicyof Carlsbad Job Address fl/lo i Wd(IUO RESIDENTIAL BUILDING PERMIT APPLICATION B-1 Plan Checkcetf';:;.o l?-..;;?30/ Est. Value 21 7, S-5 / · Q<j PC Deposit ----r----,,----- Date qj 7> /J ![ f , Suite: _____ APN: __________ _ CT/Project#: __________ Lot#: ____ Fire Sprinklers: yes/ no Air Conditioning: yes/ no BRIEF DESCRIPTION OF WORK: ~f-.... t~·K~~>=E~-~...,__~~~--~-....-~<:-l~T-+t-.... s~m~w='-""f} ... ,ft=-£,5~-- G, 0 Addition/New: _____ New SF, ___ Deck SF, ___ Patio SF, :lfj: Garage SF Is this to create an Accessory Dwelling Unit? Yes/ No New Fireplace? Yes/ No, if yes how many? __ D Remodel: _____ SF of affected area Is the area a conversion or change of use ? Yes/ No Additional Gas or Electrical Features? □ Pool/Spa: ____ SF ------------- □ Solar: ___ KW, ___ Modules, Mounted: Roof/ Ground, Tilt: Yes/ No, RMA: Yes/ No, Battery: Yes/ No Panel Upgrade: Yes/ No D Reroof: -------------------------------------- □ Plumbing/Mechanical/Electrical Only: ________________________ _ D Other:------------------------------------ :::~~ANHP1~~) /, 0) p:~::~TY~c,~W~NtER s Address: tzen}/)n\WI.. /tuf Sff /1 Address: Cb th elf O 5 f,&;j.ft.. City: fl:,Cov01 ,{}ti State: C◊ Zip: f?o?f City: C. 1 State: C,_q_ Zip: 9@ l5 Phone:qt:-Vl. ~i_ @ff_ Phone: Email:rJo&rJ(i)c,uw/4.,d d~,r e-Ctw Email:---------------- DESIGN PROFESSIONAL Name: _________________ _ Address: ________________ _ City: ________ State: __ ~Zip: ____ _ Phone: _________________ _ Email: _________________ _ Email: 7'--""'""-'----'-'~~===="""'"---'..._~<i.....:....,,...,__='-'-- Architect State License: ___________ _ State (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construJ,it.e~~r1f demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov B-1 Page 1 of 2 Rev. 06118 ( OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury one of the following declarations: ,l1A have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the 'work which this permit is issued. 0A have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the pert ance of the work for which this permit i~ssued. My workers' co pensation insurapce carrier and policy number are: Insurance ~llJ"PanyJame: ------,/--..Jl~i::::1--fr.'-'ir=-,C:~:S·_....•~--J.'--.i.!.~'=-'£'=... __ Policy No. -1.?:,;'f1.;L~_LLJ__f_2J:2_ ___ Expiration Date: !_~ /~ -( ff ~ Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, Interest and attorney's fees. a II ' t CONTRACTORSIGNATURE: -~/!DA{ b <OJ □AGENT DATE: _____ _ , ~ ~ ( OPTION B ): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Low for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale {Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). □ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 I am exempt under Section _______ ,...Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes □ No 2. 1 (have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the followi~g person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number): S. r will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address/ phone/ type of work): OWNER SIGNATURE: __________________ □AGENT DATE: _____ _ CONSTRUCTION LENDING AGENCY. IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: ______________________ Lender's Address: _____________________ _ ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 2S505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □ Yes □ No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a perio of 1 days (Section 106.4. niform Building Code). 1635 Faraday Ave Carlsbad, CA 92008 B-1 Ph: 760-602-2719 Fax: 760-604-8558 Page 2 of 2 Email: Building@carlsbadca.gov Rev. 06/18 P{:rrrnt l"ypc BLDG-Residential Application Datc· 09/05/2018 Wr.H~-C\:,1$'.,i Patio lssur, Dato 09/25/2018 :itatuc;· Closed • Finaled Exp1rat1011 Date: 07/02/2019 Scheduled Date Actual Start Date 01/03/2019 01/03/2019 02/12/2019 02/12/2019 February 12, 2019 IVR Number: 13669 Inspection Type Inspection No. BLDG-18 Exterior Lath/Drywall 080416-2019 BLDG-Final Inspection Checklist Item BLDG-Building Deficiency 083609-2019 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Structural Final BLDG-Electrical Final Inspection Status Passed COMMENTS Exterior lath OK 1/3/19 Passed COMMENTS Owner: Subdivi,,ion: Add res~: Primary Inspector Tim Frazee Tim Frazee TRUST JOSHEE-GILES FAMILY TRUST CARLSBAD TCT#88-03-03 ARROYO LA COSTA UNIT#03 2904 Camino Serbal Carlsbad, CA 92009-2900 Re inspection Passed Yes Passed Yes Yes Yes Yes Complete Complete Complete Page 2 of 2 Permit Type: BLDG-Residential Application Data: 09/05/2018 Owner: TRUST JOSHEE-GILES FAMILY TRUST Wor~ Class: Patio Issue Date: 09/25/2018 Subdivision· CARLSBAD TCT#88-03-03 ARROYO LA COSTA UNIT#03 Status: Closed -Finaled Expiration Oate: 07/02/2019 Addrnss: 2904 Camino Serbal Carlsbad, CA 92009-2900 IVR Number: 13669 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete •••-~"'"~--~ e-•-•--------~,-e,_ 10/30/2018 BLDG-31 074743-2018 Passed Paul Burnette Complete Underground/Condu it-Wiring Checklist Item COMMENTS Passf;d BLDG-Building Deficiency No 10/30/2018 10/30/2018 BLDG-21 074495-2018 Passed Paul Burnette Complete Underground/Underf loor Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-23 074496-2018 Passt,d Paul Burnette Complete Gas/Test/Repairs Checklist Item COMMENTS Passod BLDG-Building Deficiency No 11/02/2018 11102/2018 BLDG-11 075099-2018 Falled Paul Burnette Reinspection Complete Foundatlon/Ftg/Pier s (Rebar) Checklist ltt:m COMMENTS Passed BLDG-Building Deficiency No 11/05/2018 11/05/2018 BLDG-14 075134-2018 Passed Tim Frazee Complete Frame/Steel/Bolting/ Welding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Rebar mat in four (4) post holes OK 3 # 4 Yes bars each way 12/18/2018 12/18/2018 BLDG-14 079095-2018 Failed Paul Burnette Reinspection Complete Frame!Steel/Bolting/ Welding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 12124/2018 12/24/2018 BLDG-14 079741-2018 Passed Paul Burnette Complete Frame/Steel/Bolting/ Weldlng (Decks) Checklist ltom COMMENTS Passed BLDG-Building Deficiency No 12/27/2018 12/2712018 BLDG-34 Rough 079928-2018 Passed Tim Frazee Complete Electrical Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes February 12, 2019 Page 1 of 2 ,. (cicyof Carlsbad RESIDENTIAL PATIO B-8 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov Patio covers are one story, roofed structures not more than 12 feet above grade and used for outdoor recreational purposes. A building permit is required for all attached residential patio covers. Detached residential patio covers that are 120 square feet of roof area or less, do not require a permit. All patio covers, of any size, need to comply with the Zoning Ordinance, including building setbacks, structure separation requirements and lot coverage. This hand out describes what plans are necessary to secure a patio cover permit. To assist you, there is a sample of a plot plan, span tables for joists, and beams, and a footing schedule for foundation requirements. There are also connection details to use for typical connections. You may use this handout in lieu of a separate design when the patio cover is attached to the house on one complete side. If you design the patio cover yourself, or your patio cover is either free-standing or outside the span table limits in this handout, please provide a foundation plan, framing details, and other details and elevations to show the extent of the proposed work. A lateral analysis may be required for free-standing patio covers. If you use the attached tables and plans, please submit the following: 1. Two Identical Site Plans showing: a) Property lines with dimensions. b) Proposed roof area of the patio cover. c) Distances from posts to property lines. d) All existing structures on the property. e) Indicate the dimensions of the patio cover and the total roofed area. f) Any easements on the property. g) Show slopes or topography of the lot. h) Indicate percentage of lot coverage. 2. A Building Permit Application with the following: a) Name of the property owner. b) Home Phone Number c) Site address, assessor's parcel number, lot number, subdivision name or number. d) Contractor's name, State License Number and City Business License Number; or an Owner-Builder Declaration Form (Available at the Building Division Counter). e) Copy of Worker's Compensation Certificate f) Signature of Applicant If you are applying for a building permit in the Coastal Zone, you may need a Coastal Development Permit or an exemption. Contact the Planning Division for details. A Coastal Zone map is part of this handout. If you are applying for a building permit in a subdivision with a homeowner's association, you should secure architectural review prior to proceeding with the project. The City does not enforce or specifically review provisions of homeowners' association CC&R's. HOA requirements may be different than City requirements. If your home is part of a Planned Unit Development or a condominium, please see text of this handout. 8-2 Page 1 of 8 Rev. 05/12 TYPICAL R-1 PLOT PLAN ., PROPOSED FREE STANDNGPATIO ISO-FT> ~ e 'rii ;g 0 i ~ l! i .st~ 8 0 r. _______ J ______________ ~ ' ' ' ' :! : ~X:= ::'~s~~ : :! ~ __!__: -~-~ i i I I ' I I I ' ___ ,.,:. ~-~::.J - .. -------~~I:!.---~ ( REAR YARD ----- 10% EXISTNO RESIDENCE STREET 20% of LOT l'.1DTHTOA MAX. OF 20' 10%0F LOTOOTH UP TOA MAX.OF1~ LOTOOTH MEASU® 211 Setbacks shown are for R-1 parcels. Front Yard= 20' from the front property line. Interior side yard= 10% of lot width up to a maximum of 10'. (Min. 5'). Street side yard= 10'. Rear yard -20% of lot width up to a maximum of 20' (Min. 10'). Maximum lot coverage= 40%. Include solid roof patios, attached or detached in the calculation. Contact the Planning Division (760-602-4610) for information on corner lots, lots with unusual configurations, lots within Planned Communities, accessory structures and building heights. Solid Roof Patios-If roofing to be applied is TILE use the next, larger span/spacing on the following tables. Minimum Square Footing Sizes (inches)1•2 Poet Rafter Span (in feet) Snacln• 6 a 10 12 14 16 ~) 20 4 12 12 12 12 12 12 12 12 6 12 12 12 12 12 12 12 14 a 12 12 12 12 12 14 14 14 10 12 12 12 14 14 14 16 16 12 12 12 14 14 16 16 18 18 [:]BJ 12 12 14 16 16 r,no (7 !l I 20 16 12 14 14 16 18 18 20 20 18 12 14 16 18 18 20 20 22 20 14 14 16 18 20 20 22 24 1. Assumes 1,000 psf soil bearing capacity 2. The minimum depth for all footings is 12 inches into natural grade B-2 Page 2 of 8 Rev. 5/12 ,\ ,. Minimum Rafter Sizes Rafter Soacina -Center to Center (in inches) Rafter 12" (5/16" ply-:1.6" (1/2" ply-24" (1/2" ply-32" (5/8" ply- Span wood sheathina) wood sheathina\ wood sheathina\ wood sheathina\ 6 2x4 2x4 2x4 2x4 7 2x4 2x4 2x4 2x4 8 2x4 2x4 2x6 2x6 9 2x4 2x6 2x6 2x6 :I.Cl 2x6 2x6 2x6 2x6 :11 2x6 2x6 2x6 2x8 12 2x6 2x6 2x6 2x8 :L3 2x6 2x6 2x8 2x8 :1.4 2x6 2x6 2x8 2x8 1.5 2x6 2x8 2x8 2 X 10 :us 2x8 2x8 2x8 2 X 10 :1.7 , 2x8 2 x'lf 2 X 10 2 X 10 ('U& J 2x8 (2 X R' J 2 X 10 2 X 10 D 2x8 2 X 10 2 X 10 2 X 12 20 2x8 2 X 10 2 X 10 2 X 12 Minimum Beam Sizes Post Rafter Sllan (in feet) Snaclnl! 4 6 8 :I.Cl 12 :1.4 :us ~) 20 4 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4x4 6 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4x6 8 4x4 4x4 4x6 4x6 4x6 4x6 4x6 4x6 4x6 :I.Cl 4x4 4x6 4x6 4x6 4x6 4x6 4x8 4x8 4x8 12 4x6 4x6 4x8 4x8 4x8 4x8 4x8 4x8 4 X 10 6x8 6x8 6x8 6x8 :1.4 4x6 4x8 4x8 4x8 4x8 4 X 10 4 X 10 4 X 10 4 X 10 6x8 6x8 6 X 10 6 X 10 6 X 10 @) 4x8 4x8 4x8 4 X 10 4 X 10 4x 10 4 X 12 4 V 1? 4 X 14 6x8 6x8 6x8 6x 10 6 X 10 6 x 101 6 X 10 :us 4x8 4x8 4 X 10 4 X 10 4 X 10 4 X 12 4 X 12 4--X ·14 4 X 14 6x8 6x8 6x8 6 X 10 6 X 10 6 X 10 6 X 12 6 X 12 20 4x8 4 X 10 4 X 10 4 X 12 4 X 12 4 X 14 4 X 14 6x8 6x8 6 X 10 6 X 10 6 X 10 6 X 12 6 X 12 6 X 12 6 X 14 B-2 Page 3 of 8 Rev. 05/12 Figure 2 / Typical Patio See figure 3 for post to giroer detail 12" Min. Post spacing Continuous solid blocklng Bl beam between rafters Figure 3 / Post-to-Girder Connection Case 1 / Connection, Interior Condition Approved post cap 7 gauge steel 'L' straps, 1/2" wide eech side with (4) 5/8" diameter bolts, 8" along beam, 12" along post. Provide 4X4 knee brace for top-to-bottom brace on the interior side of all post-to-beam connections when post height exceeds 4'-0". Two 1/2" diameter lag bolls top & bottom (typical) Case 2 / Interior Condition APDroved post cap or 7 gauge steel 'L' straps, 1 /'1." wide eech side with ( 4) 5/8" diameter bolls, 8" along beam, 12" along post. 18" Min. I B-2 Page4 o/8 • '· Rev. 05/12 • Figure 4/ Section View of Patio A I Attached Patio Drip flash/gravel stop--~ Setback B-2 Rolled/torch -down , or built-up roof 6' a• Min. 12'0" Max. 4 X4 Post minimum 3 1/2 • Concrete slab See figure 5 for footing detail - --+-~ ,...=cSe.=ct:.:b:..::a:..::c::.k _-1l Drip flash/gravel stop Rolled/torch -down , or built-up roof--,, Boundary nail 1/2" exterkJr grede CDX. 2 X Roof framing Beam 2X Blocking @4' O" O.C. See Figure 3 4X4Post minimum ... -.. ! ••.• _. .... ••.-. ~···•··~ , .. :.• • , ..... ,.,.. :~...:• ... '-: ,• • ·::: !,, ....... ';.: •• 3 1/2 " Concrete slab Note: This example illustrate the most common case. Page 5 of 8 6'8"Min. 12' O" Max. See figure 5 for footing detail Rev. 05112 , Figure 5 / Typical Footing Details Case I / Pier Footing Natural • ., ' I Case 2 / Continuous Footing Post elevated 1' Min. above concrete or provide treated wood. r:,.Plllalbase 0 j--3'Min. L..31~12·_M_in.-4-_...,.t::jQO:i:;::;::I::;::::!: rr1' .• 4 ·. . . .-• I .. .. .. . . . . . . . . .,4 12' 3'Min. Case 3 / Slab Footing B-2 14----Post elevated 1' Min. above concrete or provide treated wood. (Dead load + Live load not exceed 750 pounds per post) --Postbase 31/2' Min. r.3'Min. 1' L,._ _ _J_ _ ____Jt:t::to :i...:::=:::r .4 Natural grade Page 6 of 8 Rev. 05/12 PATIO COVER CONSTRUCTION SPECIFICATIONS 1. Concrete All concrete for footings must be a minimum of 2,000 psi. 2. Lumber Lumber must be Douglas Fir-larch No.2 or Better. Lumber must be grade marked. All posts must be a minimum of 4x4 and may be required to be protected from decay and termites if within 8" of finish grade. 3. Connections Post anchorage shall be accomplished with a standard manufactured post base installed per the manufacturer's instructions. Footings are required when the post supports a load exceeding 750 pounds. For lesser loads, a 3 ½" slab on grade section may be substituted for required footings. When the house is used to support one end of the patio cover, the main beam may be replaced on the side attached to the house by a ledger. The ledger shall be the same size as the rafters and fastened to the structural frame of the house by ½" x 5" lag screws spaced at 32" on center for rafters up to a 10' span. Lag screws must be spaced at 16" on center for rafters between 10'1" and 20'. Rafters may not be solely supported by the existing rafter tails or facia of the house. 4. Patio Enclosures B-2 Patios may be enclosed as long as the following criteria is followed: a) Enclosure walls shall be permitted to be of any configuration, provided the open or glazed area of the longer wall and one additional wall is equal to at least 65 percent of the area below a minimum of 6 feet 8 inches (2032mm) of each wall, measured from the floor. Openings shall be permitted to be enclosed with (1) insect screening, (2) approved translucent or transparent plastic not more than 0.125 inch (3.2 mm) in thickness, (3) glass conforming to the provisions of Section R308, or (4) any combination of the foregoing. b) Patio covers shall be used only for recreational, outdoor living purposes and not as carports, garages, storage rooms or habitable rooms. c) Exterior openings required for light and ventilation shall be permitted to open into a patio structure conforming to Section AH101, provided that the patio structure shall be unenclosed if such openings are serving as emergency egress or rescue openings from sleeping rooms. Where such exterior openings serve as an exit from the dwelling unit, the patio structure, unless unenclosed, shall be provided with exits conforming to the provisions of Section R310 of this code. Page 7 of 8 Rev. 05112 5. Tables The above span and footing tables make the following assumptions: a) Roof live load is 10 psf b) Roof dead load is 7 psf c) All lumber is Douglas fir-larch No.2 or better; d) Repetitive member use e) All posts are 4x4 minimum f) Soil bearing pressure is 1000 psf minimum 6. Electrical All electrical work in a patio cover or enclosure shall be weather tight as for exterior installations. 7. Inspections a) Normally two inspections of a patio cover are required: b) When footings have been excavated but before concrete has been placed, (note: photographs of footings are not an acceptable substitute for an inspection of required footings). c) When all structural framing is completed. If solid roof sheathing is installed over the framing, a roof nailing inspection is required prior to placing the roof covering. d) Note: The project is not legally complete until the inspector of record signs the space on the job record card as final. e) The job record card and approved plans must be available for all inspections. The job record card and approved plans should then be retained by the owner as a record of the approved construction. 8. Patio covers in PUD's and Condominium projects B-2 Please call the Planning Division (760-602-4610) for site specific information. Page 8 of8 Rev. 05/12