Loading...
HomeMy WebLinkAbout2909 CACATUA ST; ; CB021213; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Building Inspection Request Line (760) 602-2725 05-2 1 -2002 Residential Permit Permit No: CB021213 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: Ap p I icant : SIGURDSON JOHN 2903 CACATUA ST CBAD RESDNTL SubType: RAD 2153901800 Lot #: 0 $30,900.00 Construction Type: NEW Reference #: 0 Structure Type: 0 Bathrooms: 0 CORTINA - RAD 300 SF Status: ISSUED Applied: 04/19/2002 Plan Approved: 05/21/2002 Issued: 05/21/2002 Entered By: JM Inspect Area: Orig PC#: Plan Check#: 4026 N CORDOBA AVENUE SPRING VALLEY CA 91977 619-855-71 60 Owner: CORTINA DAVID&PATRICIA H 7647 05/2/02 #02 01 02 2903 CACATUA ST CARLSBAD CA 92009 CGP 366.14 { Total Fees: $527.70 Total Payments To Date: $1 61.56 Balance Due: $366.14 Building Permit Addl Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee . Add'l Renewal Fee : Other Building Fee - Meter Size ' Pot. Water Con. Fee Add'l Pot. Water Con. Fee Recl. Water Con. Fee $248.55 $0.00 $1 61.56 $0.00 $0.00 $3.09 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Meter Size Addl Recl. Water Con. Fee Meter Fee SDCWA Fee CFD Payoff Fee PFF PFF (CFD Fund) License Tax License Tax (CFD Fund) Traffic Impact Fee Traffic Impact (CFD Fund) Sidewalk Fee PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Housing Impact Fee Housing InLieu Fee Master Drainage Fee Sewer Fee Additional Fees TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $62.00 $20.00 $32.50 $0.00 $0.00 $0.00 $0.00 $0.00 $527.70 You are hereby FURTHER NOTIFIED that your right to protest the specified feedexactions DOES NOT APPLY to water and sewer connectin fees and capacity PERMIT >APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 FOR OFFICE USE ONLY NTRACTOR * COMP (Sec. 7031.5 Business and Professions Code: Any City or County w improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9. commending with Section 7000 of Division 3 of the Business and Professions Code1 or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$5001). Name Address city Statelzip Telephone # State License # License Class City Business License # Designer Name Address city Statelzip Telephone Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations 0 of the work for which this permit is issued. 0 issued. My worker's compensation insurance carrier and policy number are: Insurance Company Policy No. Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$1001 OR LESS) 0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. SIGNATURE DATE 7 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If. however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 1. 2. 3. I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is 7, OWNERdUltDER DE affirm that I am exempt from the Contractor's License Law for the following reason: I am exempt under Section I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES I (have I have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name I address I phone number I contractors license number): Business and Professions Code for this reason: UNO 4. number I contractors license number): 5. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone number I type program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 0 YES 0 NO ION LWDlN I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS CANT CERTIRCATlON I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cit) of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. authorized by such permit is at any time after the APPLICANT'S SIGN DATE ?- Code shall expire by limitation and become null and void if the building or work building or work authorized by such permit is suspended or abandoned City of Carlsbad Bldg Inspection Request For: 02/19/2003 Permit# CB021213 Title: CORTINA - RAD 300 SF Description: Type: RESDNTL SubType: RAD Job Address: 2903 CACATUA ST Suite: Lot 0 Location : APPLICANT SIGURDSON JOHN Owner: CORTINA DAVID&PATRICIA H Remarks: Inspector Assignment: PY Phone: 7604382455 Inspector: Total Time: Requested By: NA CD Description Entered By: CHRISTINE 2 Comment 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Associated PCRs/CVs PCR00070 ISSUED ADD BAY WINDOWS; Date 09/06/2002 0711 912002 0711 512002 0711 512002 0711 1/2002 ow1 8/2002 06/1 a2002 ow1 812002 06/04/2002 06/04/2002 06/03/2002 06/03/2002 05/22/2002 05/22/2002 InsDection History Description 18 Exterior LathfDrywall 17 Interior LatWDrywall 16 Insulation 84 Rough Combo 14 Frame/Steel/Bolting/Welding 13 Shear PanelslHD's 15 Roof/Reroof 24 RougNTopout 1 1 FtgJFoundatiodPiers 21 Undergroundunder Floor 11 FtglFoundationlPiers ~ 21 Underground/Under Floor 21 Underground/Under Floor 24 RougNTopout Act lnsp Comments AP PY AP PY AP PY AP PY PA PY AP PY AP PY wc PY AP PY wc PY CO PY DEPTH OF SLAB wc PY AP PY wc PY EsGil CorDoration DATE: May 20,2002 JURISDICTION: Carlsbad PLAN CHECK NO.: 02-1213 SET: I1 PROJECT ADDRESS: 2903 Cacatua St. PROJECT NAME: Room Add. for Mr. & Mrs. David Cortina residence o w 0 0 o w 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction’s building codes. The plans transmitted herewith will substantially comply with the jurisdiction’s building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant’s copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted : Telephone #: Fax #: Fax In Person . All plans shall be signed by the person responsible for their preparation. Clearly show on plans all smoke detectors at the second floor bedrooms and areas giving cess to these bedrooms. . Clearly show on plans at the common walls between the Garage and the addition that the 518” type “X gypsum board shall be installed from floor-to-roof sheathing. D. City to place their “soils notice“ stamp on the plans. By: Sergio Azuela Enclosures: Esgil Corporation 0 GA 0 MB EJ 0 PC 511 3 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 EsGil Corporation Zn Tartntrsfiip witfi Government fm SuiUing Safe9 DATE: April 30,2002 JURI SDI CTI ON : Carlsbad PLAN CHECK NO.: 02-1213 0 PLAN REVIEWER 0 FILE SET: I PROJECT ADDRESS: 2903 Cacatua St. PROJECT NAME: Room Add. for Mr. & Mrs. David Cortina residence 0 The plans transmitted herewith have been corrected where necessary and substantially comply 0 The plans transmitted herewith will substantially comply with the jurisdiction’s building codes with the jurisdiction’s building codes. when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. 0 The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant‘s copy of the check list has been sent to: John S. Sigurdson 4026 N. Cordoba Ave., Spring Valley, CA 91977 Esgil Corporation staff did not advise the applicant that the plan check has been completed, Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: John S. Sigurdson (dfi.) Date ~c$-/-Ot (by: SkikJ Telephone #: (61 9) 855-71 60 Fax #: Mail Telephone Fax In Person 0 REMARKS: By: Sergio Azuela Enclosures: Esgil Corporation 0 GA MB (7 EJ 0 PC 4/22 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 + Sari Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 , I Carlsbad 02-1213 April 30, 2002 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: 02-1213 JURI SDl CTl ON: Carlsbad PROJECT ADDRESS: 2903 Cacatua St. FLOOR AREA: Dwelling Addition 300 SFSTORIES: 2 Remodel 404 SF HEIGHT: REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 4/19/02 I DATE PLANS RECEIVED BY ESGIL CORPORATION: 4/22 DATE INITIAL PLAN REVIEW COMPLETED: April 30,2002 PLAN REVIEWER: Sergio Azuela FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that residential construction comply with the 1998 edition of the California Building Code (Title 24), which adopts the following model codes: 1997 UBC, 1997 UPC, 1997 UMC and 1996 NEC (all effective 7/1/99). The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number. specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. - Carlsbad 02-12 13 April 30, 2002 0 PLANS 1. 2. 3. 4. 5. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commerciaVindustriaI projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculationslreports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). Plans, specifications and calculations shall be signed and sealed by the California state licensed engineer or architect responsible for their preparation, for plans deviating from conventional wood frame construction. Specify expiration date of license. (California Business and Professions Code). a) Structural plans. When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit. Please review Section 106.3.5. Please complete the attached form. 0 FIRE PROTECTION Show locations of permanently wired smoke detectors with battery backup: a) Inside each bedroom. b) Centrally located in corridor or area giving access to sleeping rooms. c) On each story. d) When sleeping rooms are upstairs, at the upper level in close proximity to the stair. e) In rooms adjacent to hallways serving bedrooms, when such rooms have a ceiling height 24 inches or more above the ceiling height in the hallway. . NOTE: Detectors shall sound an alarm audible in Section 310.9.1. sleeping areas of the unit. Carlsbad 02- 12 13 April 30, 2002 6. When the valuation of a room addition or repair exceeds $1,000, or when sleeping rooms are created, smoke detectors shall be provided per the above, exceDt that smoke detectors added at existing construction need only be battery powered. Section 31 0.9.1.2. 0 GENERAL RESIDENTIAL REQUIREMENTS 7. Openable window area in habitable rooms must be 1/20 of the floor area and a minimum of 5 square feet. In bathrooms and water closet compartments, 1/20 of area is required and minimum is I .5 sq. ft. Section 1203.3. a) Clearly show the size and type of the window at the bathroom. 8. Provide mechanical ventilation capable of providing five air changes per hour in bathrooms and water closet compartments if required openable windows are not provided. Section 1203.3. a) Specify it on plans for the water closet compartment. 9. Note that the discharge point for exhaust air will be at least 3 feet from any opening which allows air entry into occupied portions of the building. Section 1203.3. a) Specify it on plans for the water closet compartment. IO. Glazing in the following locations should be of safety glazing material in accordance with Section 2406.4 (see exceptions): a) Fixed and sliding panels of sliding door assemblies and panels in swinging doors other than wardrobe doors. b) Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface. 0 ROOFING 11. Specify on the plans the following information for the roof materials, per Section 106.3.3: a) Manufacturer’s name. b) Product namehumber. c) ICBO approval number, or equal. 12. Show the required ventilation for attics (or enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters). The minimum vent area is 1/150 of attic area (or 1/300 of attic area if at least 50% of the required vent is at least 3 feet above eave vents or cornice vents). Show area required and area provided. Section 1505.3. . Carlsbad 02- 12 13 April 30,2002 13. 14. 15. 16. 17. 18. 19. 20. 21. Where eave vents are installed, insulation shall not block the free flow of air. A minimum of I” of air space shall be provided between the insulation and the roof sheathing. To accommodate the thickness of insulation plus the required 1” clearance, member sizes may have to be increased for rafter-ceiling joists. Section 1505.3. Note on the plans: corrosion-resistant metal mesh with mesh openings of 1 /4-inch in dimension.” Section 1505.3. “Attic ventilation openings shall be covered with 0 GARAGE AND CARPORTS Garage requires one-hour fire protection on the garage side of walls and ceiling common to the dwelling. Table 3-B, Section 302.4. FOUNDATION REQUIREMENTS Note on plans that surface water will drain away from building and show drainage pattern. Section 1804.7. 0 FRAMING Specify truss identification numbers on the plans. Per UBC Section 2321.4, provide the following note on the plans if trusses are used: “Each truss shall be legibly branded, marked or otherwise have permanently affixed thereto the following information located within 2 feet of the center of the span on the face of the bottom chord: a) b) The design load. c) Identity of the company manufacturing the truss. The spacing of the trusses.” Specify nail size and spacing for all shear walls and roof diaphragms. Indicate required blocking. 2315 and 2513. a) Maintain maximum diaphragm dimension ratios. Sections Clearly show the roof nailing on the plans or reference any applicable specification. Also please use the same identification symbol on plans for shear walls than the one used on the shear wall schedule. Show location of attic access with a minimum size of 22”x30”, unless the maximum vertical headroom height in the attic is less than 30”. Access must be provided to each separated attic area, shall be located in a hallway or other readily accessible location and 30” headroom clearance is required above the opening. Section 1505.1. Specify plywood and/or particle board thickness, grade and panel span rating. Table 23-11-E-l . I Carlsbad 02-1213 April 30, 2002 22. 23. 24. 25. 26. 27. 28. 29. 30. 0 MECHANICAL (UNIFORM MECHANICAL CODE) Specify on the plans the following information for the fireplace(s), per Section 106.3.3: a) Manufacturer’s name. b) Model namehumber. c) d) e) ICBO approval number, or equal. Show height of chimney above roof per I.C.B.O. approval or UBC Table Note on the plans that approved spark arrestors shall be installed on all chimneys. UBC, Section 3102.3.8. 31 -B. 0 ELECTRICAL (NATIONAL ELECTRICAL CODE) Show on the plan the amperage of the electrical service, the location of the service panel and the location of any sub-panels. If service is over 200 amps, submit single line diagram, panel schedule and load calculations. Note on the plans that receptacle outlet locations will comply with NEC Art. 21 0-52(a). Show on the plan that ground-fault circuit-interrupter protection complies with NEC Art. 21 0-8, which reads as follows: All 1 25-volt, single-phase, 15- and 20- ampere receptacles installed in bathrooms. 0 ENERGY CONSERVATION Provide fluorescent general lighting (40 lumens per watt minimum) in kitchen(s) and bathrooms (containing a tub or shower). Note on the plans: “The manufactured windows shall have a label attached certified by the National Fenestration Rating Council (NFRC) and showing compliance with the energy calculations.” e MISCELLANEOUS Please clarify how? the removed exterior (shear) wall is proposed to be replaced for lateral support. Additional corrections may follow. CARLSBAD SPECIAL CODE REQUIREMENTS City (upon final transmittal) to place their “soils notice” stamp on the plans. Special inspection is required, the designer shall complete the attached Special Inspection Notice. Carlsbad 02-1213 April 30, 2002 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, Le., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes 0 No 0 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. ’ Carlsbad 02-1213 April 30, 2002 - City of Carlsbad BUILDING DEPARTMENT NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION Do Not Remove From Plans Plan Check No. 02-1213 Job Address or Legal Description 2903 Cacatua St. Owner Address You are hereby notified that in addition to the inspection of construction provided by the Building Department, an approved Registered Special Inspector is required to provide continuous inspection during the performance of the phases of construction indicated on the reverse side of this sheet. The Registered Special Inspector shall be approved by the City of Carlsbad Building Department prior to the issuance of the building permit. Special Inspectors having a current certification from the City of San Diego, Los Angeles, or ICBO are approved as Special Inspectors for the type of construction for which they are certified. The inspections by a Special Inspector do not change the requirements for inspections by personnel of the City of Carlsbad building department. The inspections by a Special Inspector are in addition to the inspections normally required by the County Building Code. The Special Inspector is not authorized to inspect and approve any work other than that for which he/she is specifically assigned to inspect. The Special Inspector is not authorized to accept alternate materials, structural changes, or any requests for plan changes. The Special Inspector is required to submit written reports to the City of Carlsbad building department of all work that he/she inspected and approved. The final inspection approval will not be given until all Special Inspection reports have been received and approved by the City of Carlsbad building department. Please submit the names of the inspectors who will perform the special inspections on each of the items indicated on the reverse side of this sheet. (over) Carlsbad 02-1213 April 30, 2002 SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION: PLAN CHECK NUMBER: OWNER’S NAME: I, as the owner, or agent of the owner (contractors may not employ the special inspector), certify that I, or the architedengineer of record, will be responsible for employing the special inspector(s) as required by Uniform Building Code (UBC) Section 1701.1 for the construction project located at the site listed above. UBC Section 106.3.5. Signed I, as the engineedarchitect of record, certify that I have prepared the following special inspection program as required by UBC Section 106.3.5 for the construction project located at the site listed above. Signed I. List of work requiring special inspection: 0 Soils Compliance Prior to Foundation Inspection 0 Structural Concrete Over 2500 PSI 0 Prestressed Concrete 0 Structural Masonry 0 Designer Specified 0 Other 0 Field Welding 0 High Strength Bolting 0 ExpansionlEpoxy Anchors 0 Sprayed-On Fireproofing 2. Name(s) of individual(s) or firm(s) responsible for the special inspections listed above: A. B. C. 3. A. B. C. ~ ~ ~ ~ Duties of the special inspectors for the work listed above: Special inspectors shall check in with the City and present their credentials for approval prior to beginning work on the job site. , CaElsbad 02-1213 April 30,2002 Jurisdiction Code cb VALUATION AND PLAN CHECK FEE By Ordinance J U Rl SDl CTI ON : Carlsbad PLAN CHECK NO.: 02-1213 ,v 1994 UBC Plan Check Fee PREPARED BY: Sergio Azuela DATE: April 30, 2002 $201.31 I BUILDING ADDRESS: 2903 Cacatua St. Room Add. / Cortina's residence BUILDING OCCUPANCY: R-3 & U-1 TYPE OF CONSTRUCTION: V-N I $309.71 I Type of Review: Complete Review 0 Structural Only 0 Repetitive Fee I3 Repeats 0 Other 0 Hourly n Hour* Esgll Plan Revlew Fee Comments: Sheet 1 of I rnacvalue.doc PLANNING/ENGlNEERING APPROVALS PERMIT NUMBER CB DATE Y/Z2/1,Z. RESlDENTlAL G RESIDENTIAL AODlTlON MINOR (< $10,000.00) TENANT IMPROVEMENT PLAZA CAMINO REAL CARtSBAD COMPANY STORES VILLAGE FAlRE COMPLETE OFFICE BUILDING PLANNER I -- ENGINEER Lo @m- Doc!UMlsfonrulphnning Cnqlncefing Aopcovals