HomeMy WebLinkAbout2909 CACATUA ST; ; CB021213; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Building Inspection Request Line (760) 602-2725
05-2 1 -2002 Residential Permit Permit No: CB021213
Job Address: Permit Type:
Parcel No:
Valuation: Occupancy Group:
# Dwelling Units: Bedrooms: Project Title:
Ap p I icant : SIGURDSON JOHN
2903 CACATUA ST CBAD RESDNTL SubType: RAD
2153901800 Lot #: 0 $30,900.00 Construction Type: NEW Reference #:
0 Structure Type:
0 Bathrooms: 0 CORTINA - RAD 300 SF
Status: ISSUED
Applied: 04/19/2002
Plan Approved: 05/21/2002 Issued: 05/21/2002
Entered By: JM
Inspect Area:
Orig PC#:
Plan Check#:
4026 N CORDOBA AVENUE SPRING VALLEY CA 91977 619-855-71 60
Owner: CORTINA DAVID&PATRICIA H
7647 05/2/02 #02 01 02 2903 CACATUA ST CARLSBAD CA 92009 CGP 366.14
{ Total Fees: $527.70 Total Payments To Date: $1 61.56 Balance Due: $366.14
Building Permit Addl Building Permit Fee Plan Check
Add'l Plan Check Fee Plan Check Discount Strong Motion Fee
Park in Lieu Fee
Park Fee LFM Fee Bridge Fee Other Bridge Fee
BTD #2 Fee
BTD #3 Fee Renewal Fee
. Add'l Renewal Fee
: Other Building Fee
- Meter Size '
Pot. Water Con. Fee
Add'l Pot. Water Con. Fee Recl. Water Con. Fee
$248.55
$0.00
$1 61.56 $0.00 $0.00
$3.09
$0.00 $0.00 $0.00
$0.00
$0.00 $0.00 $0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
Meter Size
Addl Recl. Water Con. Fee
Meter Fee SDCWA Fee CFD Payoff Fee PFF
PFF (CFD Fund) License Tax License Tax (CFD Fund) Traffic Impact Fee
Traffic Impact (CFD Fund) Sidewalk Fee PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Housing Impact Fee
Housing InLieu Fee Master Drainage Fee Sewer Fee Additional Fees
TOTAL PERMIT FEES
$0.00 $0.00 $0.00
$0.00
$0.00
$0.00 $0.00
$0.00
$0.00
$0.00 $0.00 $62.00 $20.00 $32.50
$0.00
$0.00 $0.00 $0.00
$0.00
$527.70
You are hereby FURTHER NOTIFIED that your right to protest the specified feedexactions DOES NOT APPLY to water and sewer connectin fees and capacity
PERMIT >APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008
FOR OFFICE USE ONLY
NTRACTOR * COMP
(Sec. 7031.5 Business and Professions Code: Any City or County w improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
[Chapter 9. commending with Section 7000 of Division 3 of the Business and Professions Code1 or that he is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$5001).
Name Address city Statelzip Telephone #
State License # License Class City Business License #
Designer Name Address city Statelzip Telephone
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations
0 of the work for which this permit is issued.
0 issued. My worker's compensation insurance carrier and policy number are:
Insurance Company Policy No. Expiration Date
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$1001 OR LESS)
0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees.
SIGNATURE DATE
7 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If. however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
0
1.
2.
3.
I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
7, OWNERdUltDER DE
affirm that I am exempt from the Contractor's License Law for the following reason:
I am exempt under Section
I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES
I (have I have not) signed an application for a building permit for the proposed work.
I have contracted with the following person (firm) to provide the proposed construction (include name I address I phone number I contractors license number):
Business and Professions Code for this reason:
UNO
4.
number I contractors license number):
5.
I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone
I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone number I type
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
0 YES 0 NO
ION LWDlN
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code).
LENDER'S NAME LENDER'S ADDRESS
CANT CERTIRCATlON
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cit) of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
authorized by such permit is
at any time after the
APPLICANT'S SIGN DATE ?-
Code shall expire by limitation and become null and void if the building or work
building or work authorized by such permit is suspended or abandoned
City of Carlsbad Bldg Inspection Request
For: 02/19/2003
Permit# CB021213
Title: CORTINA - RAD 300 SF
Description:
Type: RESDNTL SubType: RAD
Job Address: 2903 CACATUA ST
Suite: Lot 0
Location :
APPLICANT SIGURDSON JOHN
Owner: CORTINA DAVID&PATRICIA H
Remarks:
Inspector Assignment: PY
Phone: 7604382455
Inspector:
Total Time: Requested By: NA
CD Description
Entered By: CHRISTINE 2 Comment 19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Associated PCRs/CVs
PCR00070 ISSUED ADD BAY WINDOWS;
Date
09/06/2002
0711 912002
0711 512002
0711 512002
0711 1/2002 ow1 8/2002
06/1 a2002 ow1 812002
06/04/2002
06/04/2002
06/03/2002
06/03/2002
05/22/2002
05/22/2002
InsDection History
Description
18 Exterior LathfDrywall
17 Interior LatWDrywall
16 Insulation
84 Rough Combo
14 Frame/Steel/Bolting/Welding
13 Shear PanelslHD's
15 Roof/Reroof
24 RougNTopout
1 1 FtgJFoundatiodPiers
21 Undergroundunder Floor
11 FtglFoundationlPiers ~
21 Underground/Under Floor
21 Underground/Under Floor
24 RougNTopout
Act lnsp Comments
AP PY
AP PY
AP PY
AP PY
PA PY
AP PY
AP PY wc PY
AP PY wc PY
CO PY DEPTH OF SLAB wc PY
AP PY wc PY
EsGil CorDoration
DATE: May 20,2002
JURISDICTION: Carlsbad
PLAN CHECK NO.: 02-1213 SET: I1
PROJECT ADDRESS: 2903 Cacatua St.
PROJECT NAME: Room Add. for Mr. & Mrs. David Cortina residence
o
w
0
0
o
w
0
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction’s building codes.
The plans transmitted herewith will substantially comply with the jurisdiction’s building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant’s copy of the check list has been sent to:
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted : Telephone #:
Fax #:
Fax In Person
. All plans shall be signed by the person responsible for their preparation.
Clearly show on plans all smoke detectors at the second floor bedrooms and areas giving
cess to these bedrooms. . Clearly show on plans at the common walls between the Garage and the addition that the 518”
type “X gypsum board shall be installed from floor-to-roof sheathing.
D. City to place their “soils notice“ stamp on the plans.
By: Sergio Azuela Enclosures:
Esgil Corporation 0 GA 0 MB EJ 0 PC 511 3 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
EsGil Corporation
Zn Tartntrsfiip witfi Government fm SuiUing Safe9
DATE: April 30,2002
JURI SDI CTI ON : Carlsbad
PLAN CHECK NO.: 02-1213
0 PLAN REVIEWER
0 FILE
SET: I
PROJECT ADDRESS: 2903 Cacatua St.
PROJECT NAME: Room Add. for Mr. & Mrs. David Cortina residence
0 The plans transmitted herewith have been corrected where necessary and substantially comply
0 The plans transmitted herewith will substantially comply with the jurisdiction’s building codes
with the jurisdiction’s building codes.
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
0 The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant‘s copy of the check list has been sent to:
John S. Sigurdson
4026 N. Cordoba Ave., Spring Valley, CA 91977
Esgil Corporation staff did not advise the applicant that the plan check has been completed,
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: John S. Sigurdson (dfi.)
Date ~c$-/-Ot (by: SkikJ
Telephone #: (61 9) 855-71 60
Fax #:
Mail Telephone Fax In Person 0 REMARKS:
By: Sergio Azuela Enclosures:
Esgil Corporation 0 GA MB (7 EJ 0 PC 4/22 tmsmtl.dot
9320 Chesapeake Drive, Suite 208 + Sari Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
,
I Carlsbad 02-1213
April 30, 2002
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK NO.: 02-1213 JURI SDl CTl ON: Carlsbad
PROJECT ADDRESS: 2903 Cacatua St.
FLOOR AREA: Dwelling Addition 300 SFSTORIES: 2
Remodel 404 SF
HEIGHT:
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 4/19/02 I DATE PLANS RECEIVED BY
ESGIL CORPORATION: 4/22
DATE INITIAL PLAN REVIEW
COMPLETED: April 30,2002
PLAN REVIEWER: Sergio Azuela
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinance by the Planning Department, Engineering Department, Fire
Department or other departments. Clearance from those departments may be required prior to
the issuance of a building permit.
Present California law mandates that residential construction comply with the 1998 edition of
the California Building Code (Title 24), which adopts the following model codes: 1997 UBC,
1997 UPC, 1997 UMC and 1996 NEC (all effective 7/1/99).
The above regulations apply to residential construction, regardless of the code editions adopted
by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number. specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
- Carlsbad 02-12 13
April 30, 2002
0 PLANS
1.
2.
3.
4.
5.
Please make all corrections on the original tracings, as requested in the correction
list. Submit three sets of plans for commerciaVindustriaI projects (two sets of plans
for residential projects). For expeditious processing, corrected sets can be
submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculationslreports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
All sheets of plans must be signed by the person responsible for their
preparation. (California Business and Professions Code).
Plans, specifications and calculations shall be signed and sealed by the
California state licensed engineer or architect responsible for their preparation,
for plans deviating from conventional wood frame construction. Specify
expiration date of license. (California Business and Professions Code).
a) Structural plans.
When special inspection is required, the architect or engineer of record shall
prepare an inspection program which shall be submitted to the building official
for approval prior to issuance of the building permit. Please review Section
106.3.5. Please complete the attached form.
0 FIRE PROTECTION
Show locations of permanently wired smoke detectors with battery backup:
a) Inside each bedroom.
b) Centrally located in corridor or area giving access to sleeping rooms. c) On each story.
d) When sleeping rooms are upstairs, at the upper level in close proximity to the stair.
e) In rooms adjacent to hallways serving bedrooms, when such rooms have a ceiling height 24 inches or more above the ceiling height in the hallway. . NOTE: Detectors shall sound an alarm audible in
Section 310.9.1.
sleeping areas of the unit.
Carlsbad 02- 12 13
April 30, 2002
6. When the valuation of a room addition or repair exceeds $1,000, or when
sleeping rooms are created, smoke detectors shall be provided per the above,
exceDt that smoke detectors added at existing construction need only be battery
powered. Section 31 0.9.1.2.
0 GENERAL RESIDENTIAL REQUIREMENTS
7. Openable window area in habitable rooms must be 1/20 of the floor area and a
minimum of 5 square feet. In bathrooms and water closet compartments, 1/20 of
area is required and minimum is I .5 sq. ft. Section 1203.3.
a) Clearly show the size and type of the window at the bathroom.
8. Provide mechanical ventilation capable of providing five air changes per hour in
bathrooms and water closet compartments if required openable windows are not
provided. Section 1203.3.
a) Specify it on plans for the water closet compartment.
9. Note that the discharge point for exhaust air will be at least 3 feet from any
opening which allows air entry into occupied portions of the building. Section
1203.3.
a) Specify it on plans for the water closet compartment.
IO. Glazing in the following locations should be of safety glazing material in
accordance with Section 2406.4 (see exceptions):
a) Fixed and sliding panels of sliding door assemblies and panels in swinging
doors other than wardrobe doors.
b) Fixed or operable panels adjacent to a door where the nearest exposed
edge of the glazing is within a 24-inch arc of either vertical edge of the door
in a closed position and where the bottom exposed edge of the glazing is
less than 60 inches above the walking surface.
0 ROOFING
11. Specify on the plans the following information for the roof materials, per Section
106.3.3:
a) Manufacturer’s name.
b) Product namehumber.
c) ICBO approval number, or equal.
12. Show the required ventilation for attics (or enclosed rafter spaces formed where
ceilings are applied directly to the underside of roof rafters). The minimum vent
area is 1/150 of attic area (or 1/300 of attic area if at least 50% of the required
vent is at least 3 feet above eave vents or cornice vents). Show area required
and area provided. Section 1505.3.
. Carlsbad 02- 12 13
April 30,2002
13.
14.
15.
16.
17.
18.
19.
20.
21.
Where eave vents are installed, insulation shall not block the free flow of air. A
minimum of I” of air space shall be provided between the insulation and the roof
sheathing. To accommodate the thickness of insulation plus the required 1”
clearance, member sizes may have to be increased for rafter-ceiling joists.
Section 1505.3.
Note on the plans:
corrosion-resistant metal mesh with mesh openings of 1 /4-inch in dimension.”
Section 1505.3.
“Attic ventilation openings shall be covered with
0 GARAGE AND CARPORTS
Garage requires one-hour fire protection on the garage side of walls and ceiling
common to the dwelling. Table 3-B, Section 302.4.
FOUNDATION REQUIREMENTS
Note on plans that surface water will drain away from building and show drainage
pattern. Section 1804.7.
0 FRAMING
Specify truss identification numbers on the plans.
Per UBC Section 2321.4, provide the following note on the plans if trusses are
used: “Each truss shall be legibly branded, marked or otherwise have
permanently affixed thereto the following information located within 2 feet of the
center of the span on the face of the bottom chord:
a) b) The design load.
c)
Identity of the company manufacturing the truss.
The spacing of the trusses.”
Specify nail size and spacing for all shear walls and roof diaphragms. Indicate
required blocking.
2315 and 2513.
a)
Maintain maximum diaphragm dimension ratios. Sections
Clearly show the roof nailing on the plans or reference any applicable
specification. Also please use the same identification symbol on plans for
shear walls than the one used on the shear wall schedule.
Show location of attic access with a minimum size of 22”x30”, unless the
maximum vertical headroom height in the attic is less than 30”. Access must be
provided to each separated attic area, shall be located in a hallway or other
readily accessible location and 30” headroom clearance is required above the
opening. Section 1505.1.
Specify plywood and/or particle board thickness, grade and panel span rating.
Table 23-11-E-l .
I Carlsbad 02-1213
April 30, 2002
22.
23.
24.
25.
26.
27.
28.
29.
30.
0 MECHANICAL (UNIFORM MECHANICAL CODE)
Specify on the plans the following information for the fireplace(s), per Section
106.3.3:
a) Manufacturer’s name.
b) Model namehumber.
c)
d)
e)
ICBO approval number, or equal.
Show height of chimney above roof per I.C.B.O. approval or UBC Table
Note on the plans that approved spark arrestors shall be installed on all
chimneys. UBC, Section 3102.3.8.
31 -B.
0 ELECTRICAL (NATIONAL ELECTRICAL CODE)
Show on the plan the amperage of the electrical service, the location of the
service panel and the location of any sub-panels. If service is over 200 amps,
submit single line diagram, panel schedule and load calculations.
Note on the plans that receptacle outlet locations will comply with NEC Art.
21 0-52(a).
Show on the plan that ground-fault circuit-interrupter protection complies with
NEC Art. 21 0-8, which reads as follows:
All 1 25-volt, single-phase, 15- and 20- ampere receptacles installed in
bathrooms.
0 ENERGY CONSERVATION
Provide fluorescent general lighting (40 lumens per watt minimum) in kitchen(s)
and bathrooms (containing a tub or shower).
Note on the plans: “The manufactured windows shall have a label attached
certified by the National Fenestration Rating Council (NFRC) and showing
compliance with the energy calculations.”
e MISCELLANEOUS
Please clarify how? the removed exterior (shear) wall is proposed to be replaced
for lateral support. Additional corrections may follow.
CARLSBAD SPECIAL CODE REQUIREMENTS
City (upon final transmittal) to place their “soils notice” stamp on the plans.
Special inspection is required, the designer shall complete the attached Special
Inspection Notice.
Carlsbad 02-1213
April 30, 2002
To speed up the review process, note on this list (or a copy) where each correction item
has been addressed, Le., plan sheet, note or detail number, calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a result
of corrections from this list. If there are other changes, please briefly describe them
and where they are located in the plans.
Have changes been made to the plans not resulting from this correction list? Please
indicate:
Yes 0 No 0
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to
perform the plan review for your project. If you have any questions regarding these plan
review items, please contact Sergio Azuela at Esgil Corporation. Thank you.
’ Carlsbad 02-1213
April 30, 2002
- City of Carlsbad
BUILDING DEPARTMENT
NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION
Do Not Remove From Plans
Plan Check No. 02-1213
Job Address or Legal Description 2903 Cacatua St.
Owner Address
You are hereby notified that in addition to the inspection of construction provided by the
Building Department, an approved Registered Special Inspector is required to provide continuous
inspection during the performance of the phases of construction indicated on the reverse side of
this sheet.
The Registered Special Inspector shall be approved by the City of Carlsbad Building
Department prior to the issuance of the building permit. Special Inspectors having a
current certification from the City of San Diego, Los Angeles, or ICBO are approved as
Special Inspectors for the type of construction for which they are certified.
The inspections by a Special Inspector do not change the requirements for inspections by
personnel of the City of Carlsbad building department. The inspections by a Special
Inspector are in addition to the inspections normally required by the County Building
Code.
The Special Inspector is not authorized to inspect and approve any work other than that for which
he/she is specifically assigned to inspect. The Special Inspector is not authorized to accept
alternate materials, structural changes, or any requests for plan changes. The Special Inspector is
required to submit written reports to the City of Carlsbad building department of all work that
he/she inspected and approved. The final inspection approval will not be given until all Special
Inspection reports have been received and approved by the City of Carlsbad building department.
Please submit the names of the inspectors who will perform the special inspections on each of the
items indicated on the reverse side of this sheet.
(over)
Carlsbad 02-1213
April 30, 2002
SPECIAL INSPECTION PROGRAM
ADDRESS OR LEGAL DESCRIPTION:
PLAN CHECK NUMBER: OWNER’S NAME:
I, as the owner, or agent of the owner (contractors may not employ the special inspector), certify that I, or the architedengineer of record, will be responsible for employing the special
inspector(s) as required by Uniform Building Code (UBC) Section 1701.1 for the construction
project located at the site listed above. UBC Section 106.3.5.
Signed
I, as the engineedarchitect of record, certify that I have prepared the following special inspection
program as required by UBC Section 106.3.5 for the construction project located at the site listed above.
Signed
I. List of work requiring special inspection:
0 Soils Compliance Prior to Foundation Inspection 0 Structural Concrete Over 2500 PSI 0 Prestressed Concrete 0 Structural Masonry 0 Designer Specified 0 Other
0 Field Welding 0 High Strength Bolting 0 ExpansionlEpoxy Anchors 0 Sprayed-On Fireproofing
2. Name(s) of individual(s) or firm(s) responsible for the special inspections listed
above:
A.
B.
C.
3.
A.
B.
C.
~ ~ ~ ~
Duties of the special inspectors for the work listed above:
Special inspectors shall check in with the City and present their credentials for approval prior to beginning work on the job site.
, CaElsbad 02-1213
April 30,2002
Jurisdiction Code cb
VALUATION AND PLAN CHECK FEE
By Ordinance
J U Rl SDl CTI ON : Carlsbad PLAN CHECK NO.: 02-1213
,v 1994 UBC Plan Check Fee
PREPARED BY: Sergio Azuela DATE: April 30, 2002
$201.31 I
BUILDING ADDRESS: 2903 Cacatua St. Room Add. / Cortina's residence
BUILDING OCCUPANCY: R-3 & U-1 TYPE OF CONSTRUCTION: V-N
I $309.71 I
Type of Review: Complete Review 0 Structural Only
0 Repetitive Fee I3 Repeats
0 Other
0 Hourly n Hour*
Esgll Plan Revlew Fee
Comments:
Sheet 1 of I
rnacvalue.doc
PLANNING/ENGlNEERING APPROVALS
PERMIT NUMBER CB DATE Y/Z2/1,Z.
RESlDENTlAL G
RESIDENTIAL AODlTlON MINOR (< $10,000.00)
TENANT IMPROVEMENT
PLAZA CAMINO REAL
CARtSBAD COMPANY STORES
VILLAGE FAlRE
COMPLETE OFFICE BUILDING
PLANNER
I
-- ENGINEER Lo @m-
Doc!UMlsfonrulphnning Cnqlncefing Aopcovals