HomeMy WebLinkAbout2910 CORTE JARDIN; ; CB982821; PermitBUILDING PERMIT
10/15/98 14 03
Page 1 of 1
Job Address 2910 CORTE JARDIN Suite
Permit Type RESIDENTAL ADD/ALT
Parcel No 255-144-57-00 Lot#
Valuation 63,602
Occupancy Group Reference*
Description RAD 649 SF-FAMILY ROOM AND HAL
BATH
Permit No
Project No
Development No
CB982821
A9803680
Appl/Ownr
***Fees
MARLOW RAYMOND
PO BOX 8217
RANCHO SANTA FE
Required ***
760
Construction Type
Status
Applied
Apr/Issue
Entered By
434-0424
CA 92067
'•"***Fees 01
£r£SMT_
VN
ISSUED
08/26/98
10/15/98
JM
02***
5Z.Q_-OQ
Fees 872 00
Adjustments , 00
Total Fees . 872. 00
Fee description
: Total Credits
Total Payments
Balance Due.
Units Fee/Unit
00
302 00
570 00
Ext fee Data
Building Permit : :,
Plan Check -••'• •, - :
Strong Motion Fee.
* BUILDING TOTAL ' • \','-. '-"_' -
Enter "Y" for Plumbing Issue Fee > ...'•'.
Each Plumbing Fixture or Trap .' > ;•. ;
Each Building Sewer : ;.>'•'
Each Install/Repair Water Line >
Each Vacuum Breaker - > .'-..,...
Enter "Y" for Electric Issue Fee >
Enter "Y" for Remodel •-. . • > - -
Enter 'Y' for Mechanical Issue Fee>
Install Furn/Ducts/Heat Pumps ',••.>•
•'. '; .
.. '••!'•'/ ' 1
;:i is
1 7 ,
1 7.
1 . 9
00
00
00
00
00
464
302
6
772
20
7
15
7
7
10
10
15
9
00
00
00
00
00
00
00
00
00
00
00
00
00
Y
Y
Y
Y
FINAL APPROVA'
INSP.DATE
CLEARANCE
CITY OF CARLSBAD
2075 Las Palmas Dr , Carlsbad, CA 92009 (619) 438-1161
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
2075 Las Palmas Dr, Carlsbad CA 92009
(760)438-1161
PROJECT INFORMATION
FOR OFFICE USE ONLY
PLAN CHECK
EST VAL
Plan Ck Deposit
Validated By ^
Date
Address (include Bldg/Suite #)Business Name (at this address)
/
Description of Work SO. FT #of Stories # of Bedrooms # of Bathrooms
bl\lj(7piff8rent"frbm applicant)
Name x^
J3 APPLICAKm "
Address City
[~1 Agent for Contractor ;;: O Owner T CpAgent 'or Owner~
State/Zip Telephone #Fax
Address City State/Zip Telephone
"plOPERfYjDWNER
Name " ' Address ' City State/Zip Telephone #
(Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter improve demolish or repair any structure prior to its
issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law
(Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Codel or that he is exempt therefrom and the basis for the alleged
exemptipn .Any violation of Section 703^5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500])
Pf) Gty £u7 PrP C.*\i M7 7{&-
Nadxf
State License # 6 -
Address «-.
/ft *f "•? 4] License Class ^7_Z
City State/Zip
City Business License # ^M*-
, Telephone #
Designer Name / /
State License # ^/f^>
Address City State/Zip Telephone
6 l.WOMER/ CoWpEWSATION
Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations
Q I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance
of the work for which this permit is issued
n I have and will maintain workers compensation as required by Section 3700 of the Labor Code for the performance of the work for which this permit is
issued My worker s compensation insurance carrier and policy number are
Insurance Company Policy No Expiration Date
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS)
n CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as
to become subject to the Workers Compensation Laws of California
WARNING Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollaj»-t$TJSO 000) in addrtion tjo/the cost of compensation damages as provided for in Section 3706 of the Labor code interest and attorney s fees
SIGNATURE ^^L^TTT^/ /Vf/%^ (^- DATE &•-*-?*&
7 .„ OWNER MLDJ^DECLA^A'TON JpF jip ^T jiT IF -5? - "b^L "yri!
I hereby affirm that I am exempt from the Contractor s License Law for the following reason
[U I as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale
(Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and who does
such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is
sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale)
l~l I as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The
Contractor s License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(s) licensed
pursuant to the Contractor s License Law)
l~l I am exempt under Section Business and Professions Code for this reason
1 I personally plan to provide the major labor and materials for construction of the proposed property improvement d YES [UNO
2 I (have / have not) signed an application for a building permit for the proposed work
3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number)
4 I plan to provide portions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone
number / contractors license number)
5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work)
PROPERTY OWNER SIGNATURE
COMPLET E'THJS SECTION
DATE
BUILDING PERMITS Ol\ILY ^i .. ^ : *p' "i::h:::;. ' ........... r ...-' A.,
Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention
program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act? £] YES O NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? fj YES l~l NO
Is the facility to be constructed within 1 000 feet of the outer boundary of a school site? d YES Q NO
IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT
;s -IliwsjiuiTO^ •••;r'-:S,3ii:i:.C;^L,,i,,.jf;k;i J,l . .. rV':1!!!™:"^. >_•• n iiT" , .. ."".. •
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code)
LENDER S NAME LENDER S ADDRESS
'•'SET "APPLICANT; CERTIFICATION:!^;;.. ; -™ j
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all
City ordinances and State laws relating to building construction I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned
property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES
JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
OSHA An OSHA permit is required for excavations over 5 0" deep and demolition or construction of structures over 3 stories in height
EXPIRATION Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or
work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by such permit is suspended
or abandoned at any time after the work is commenced for a period of 180 days (Section 106 4 4 Uniform Building Code)
APPLICANT S SIGNATURE DATE
WHITE File YELLOW Applicant PINK Finance
BUILDING PERMIT Permit No: CB982821
10/14/98 15:26 Project No: A9803680
Page 1 of 1 Development No:
Job Address: 2910 CORTE JARDIN Suite:
Permit Type: RESIDENTAL ADD/ALT
Parcel No: 255-144-57-00 Lot#:
Valuation: 63,602 Construction Type. VN
Occupancy Group: Referenced Status. APPROVED
Description: RAD 649 SF-FAMILY ROOM AND HAL Applied: 08/26/98
: BATH Apr/Issue. 10/14/98
Entered By: JM
Appl/Ownr : MARLOW RAYMOND 760 434-0424
PO BOX 8217
RANCHO SANTA FE CA 92067
*** Fees Required *** *** Fees Collected & Credits ***
Fees: 872.00
Adjustments: .00
Total Fees: 872.00
Fee description
Total Credits:
Total Payments.
Balance Due:
Units Fee/Unit
.00
302.00
570.00
Ext fee Data
Building Permit
Plan Check
Strong Motion Fee
* BUILDING TOTAL
Enter "Y" for Plumbing Issue Fee >
Each Plumbing Fixture or Trap >
Each Building Sewer >
Each Install/Repair Water Line >
Each Vacuum Breaker >
Enter "Y" for Electric Issue Fee >
Enter "Y" for Remodel >
Enter 'Y1 for Mechanical Issue Fee>
Install Furn/Ducts/Heat Pumps >
1
1
1
1
1
7
15
7
7
9
.00
.00
.00
.00
.00
464.
302.
6.
772.
20.
7.
15.
7.
7
10
10
15
9
00
00
00
00
00
00
00
00
00
00
00
00
00
Y
Y
Y
Y
City of Carlsbad Inspection Request
For 2/25/99
Permit# CB982821
Title RAD 649 SF-FAMILY ROOM AND HAL
Description BATH
Inspector Assignment DH
2910 CORTEJARDIN
Lot
Type RAD Sub Type
Job Address
Suite
Location
APPLICANT MARLOW RAYMOND
Owner NORTON JON O&DIANA B
Remarks
Phone 6197561610
Inspector
Total Time Requested By RAYMOND
Entered By CHRISTINE
CD Description
19 Final Structural
Act „ Comments
A?
29 Final Plumbing \
39 Final Electrical j
49 Final Mechanical J/
V
Inspection History
Date
12/30/98
11/19/98
11/13/98
11/9/98
11/9/98
10/29/98
10/19/98
10/16/98
Description
18 Exterior Lath/Drywall
18 Exterior Lath/Drywall
16 Insulation
13 Shear Panels/HDs
84 Rough Combo
1 5 Roof/Reroof
1 1 Ftg/Foundation/Piers
1 1 Ftg/Foundation/Piers
Act
AP
AP
AP
CO
CO
CO
AP
NR
Insp
DH
DH
DH
DH
DH
DH
DH
DH
Comments
C/DRYWALL ONLY
SEE NOTE ON CARD
PROV PLANS/PERMITS
City of Carlsbad Inspection Request
For 2/23/99
Permit# CB982821
Title RAD 649 SF-FAMILY ROOM AND HAL
Description BATH
Inspector Assignment DH
2910 CORTEJARDIN
Lot
Type RAD Sub Type
Job Address
Suite
Location
APPLICANT MARLOW RAYMOND
Owner NORTON JON O&DIANA B
Remarks
Total Time
Phone 6197561610
Inspector
Requested By RAYMOI*
Entered By CHRISTIE
CD Description
19 Final Structural
Act Comment:ents
.
Inspection History /
Date
12/30/98
11/19/98
11/13/98
11/9/98
11/9/98
10/29/98
10/19/98
10/16/98
Description
18 Exterior Lath/Drywall
18 Exterior Lath/Drywall
16 Insulation
13 Shear Panels/HDs
84 Rough Combo
1 5 Roof/Reroof
1 1 Ftg/Foundation/Piers
1 1 Ftg/Foundation/Piers
Act
AP
AP
AP
CO
CO
CO
AP
NR
Insp
DH
DH
DH
DH
DH
DH
DH
DH
Comments /
/
C/DRYWALL ONLY /
/
SEE NOTE ON CARD /
/
PROV PLANS/PERMITS /
I
EsGil Corporation
In Partnership with government for 'BmCding Safety
DATE 10/13/98 Q APPblgANT
JURISDICTION Carlsbad
a FILE
PLAN CHECK NO 98-2821 SET III
PROJECT ADDRESS 2910 Corte Jardm
PROJECT NAME Room addition for Norton Residence
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
I I The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Telephone #
Date contacted (by ) Fax #
Mail Telephone Fax In Person
REMARKS
By Ray Fuller Enclosures
Esgil Corporation
D GA D MB D EJ D PC 10/06/98 trnsmtldot
9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (619) 560-1468 •* Fax (619) 560-1576
EsGil Corporation
In TartnersHip with government for Quitting Safety
DATE 10/01/98
JURISDICTION Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO 98-2821 SET II
PROJECT ADDRESS 2910 Corte Jardm
PROJECT NAME Norton Room Addition
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
I I The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
I | The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
IXi The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
IXI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
IXI The applicant's copy of the check list has been sent to
Raymond Marcon
P O Box 8217 Rancho Santa Fe, Ca 92067
IX! Esgil Corporation staff did not advise the applicant, except by mail, that the plan check has
been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Telephone #
Date contacted (by ) Fax #
Mail Telephone Fax In Person
REMARKS
By Ray Fuller Enclosures
Esgil Corporation
D GA D MB D EJ D PC 09/22/98 trnsmtldot
9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 * (619)560-1468 •* Fax (619) 560-1576
Carlsbad 98-2821
10/01/98
II
RECHECK PLAN CORRECTION LIST
JURISDICTION Carlsbad
PROJECT ADDRESS 2910 Corte Jardin
DATE PLAN RECEIVED BY
ESGIL CORPORATION 09/22/98
REVIEWED BY Ray Fuller
PLAN CHECK NO 98-2821
SET II
DATE RECHECK COMPLETED
10/01/98
FOREWORD (PLEASE READ)
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access This plan review is
based on regulations enforced by the Building Department You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3,
1994 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law
A Please make all corrections on the original tracings and submit two new sets of prints to
ESGIL CORPORATION
B To facilitate recheckmg, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans
C The following items have not been resolved from the previous plan reviews The original
correction number has been given for your reference In case you did not keep a copy of
the prior correction list, we have enclosed those pages containing the outstanding
corrections Please contact me if you have any questions regarding these items
D Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list If there are other changes, please briefly describe them and where
they are located on the plans Have changes been made not resulting from this list?
QYes QNo
Carlsbad 98-2821 II
10/01/98
• The items listed below are from the previous list These remaining items have
not been adequately addressed The remarks in bold are to emphasize the
remaining problem
• Please make all corrections on the original tracings, as requested in the correction
list
Submit three sets of plans for commercial/industrial projects (two sets of plans for
residential projects) For expeditious processing, corrected sets can be submitted in
one of two ways
1 Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA 92009, (760)
438-1161 The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments
2 Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (619) 560-1468 Deliver
all remaining sets of plans and calculations/reports directly to the City of Carlsbad
Building Department for routing to their Planning, Engineering and Fire Departments
NOTE Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete
• 21 ) Show wall bracing Every exterior wood stud wall and mam cross-stud partition
shall be braced at each end within 8'-0" and at least every 25 feet of length
Section 2326 11 3 and Table 23-l-W Please show the braced wall length or
alternate braced wall length and requirements from UBC Section 2326 11 4 on the
plans or provide design and calculations from a licensed Engineer or Architect for
the lateral analysis of the structure proposed and have the Engineer or Architect
stamp seal with expiration date and sign the calculations and the structural sheets
of the plans On page 2 starting at bottom at optional door and working
clockwise the following corrections would have to be done to comply with
current conventional standards per Section 2326 113 Note let in braces are no
longer allowed as a lateral braced system m Seismic Zones 3 and 4
• a ) At optional door provide a plywood shear panel at each side of door
and note it must extend to upper roof sheathing Provide holdowns at each
endto4x4^s (4 total)
• b) Long wall on left show as stucco shear (No holdowns are required)
• c) The 2x6 transverse wall shown needs footing shown underneath on
page 4 This also is a shear wall extending to roof sheathing and no
holdowns required
• d) Along front wall show (2) shear walls at least 27" wide The one
location is fine add - another at far corner next to window 5 All Hold
downs and shear per your noted schedule of Vi ply 10d 4 & 12 HDSA's to 4
x4's with SSTB 2(Ts Note minimum 5/8 anchor bolts at 24" o/c , minimum 2
per shear panel A-35's at 12" o/c above these shear walls
Carlsbad 98-2821 II
10/01/98
• 28 ) Provide plans, calculations and worksheets to show compliance with current
energy standards You are proposing 52% glazing for room addition The
maximum is 20% plus any removed glazing Your only possible option is a
computer program probably doing the entire house
• 30 ) All energy items shown on the plans must be in agreement with the
information shown on the properly completed Form CF-IR Please show the
required insulation values for wall and ceilings on the plans How do you propose
to obtain R-30 in 2 x 8 rafter/ceiling joist space7
• The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123, telephone number of 619/560-1468,
to perform the plan review for your project If you have any questions regarding
these plan review items, please contact Ray Fuller at Esgil Corporation Thank
you
EsGil Corporation
In ^Partnership With government for 'Buitding Safety
DATE 9/10/98 a APPLICANT"""
JURISDICTION Carlsbad a PLAN REVIEWER
D FILE
PLAN CHECK NO 98-2821 SET I
PROJECT ADDRESS 2910 Corte Jardin
PROJECT NAME Norton Room Addition
I I The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department
staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
I The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
I The applicant's copy of the check list has been sent to
Raymond Marcon
PO Box 8217 Rancho Santa Fe, Ca 92067
H Esgil Corporation staff did not advise the applicant, except by mail, that the plan check has
been completed
I | Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Telephone #
Date contacted ll/ofa (by/^G) Fax #
Mail y Telephone Fax In Person
REMARKS
By Mike Puckett Enclosures
Esgil Corporation
D GA D CM D EJ D PC 8/27/98 tmsmtldot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 * (619)560-1468 + Fax (619) 560-1576
Carlsbad 98-2821
9/10/98
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK NO 98-2821 JURISDICTION Carlsbad
PROJECT ADDRESS 2910 Corte Jardm
FLOOR AREA 649sfRmAdd
REMARKS
DATE PLANS RECEIVED BY
JURISDICTION 8/26/98
DATE INITIAL PLAN REVIEW
COMPLETED 9/10/98
STORIES 1
HEIGHT
DATE PLANS RECEIVED BY
ESGIL CORPORATION 8/27/98
PLAN REVIEWER Mike Puckett
FOREWORD (PLEASE READ)
This plan review is limited to the technical requirements contained in the Uniform Building
Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state
laws regulating energy conservation, noise attenuation and access for the disabled This plan
review is based on regulations enforced by the Building Department You may have other
corrections based on laws and ordinance by the Planning Department, Engineering
Department, Fire Department or other departments Clearance from those departments may be
required prior to the issuance of a building permit
Present California law mandates that residential construction comply with Title 24 and the
following model codes 1994 UBC (effective 12/28/95), 1994 UPC (effective 12/28/95), 1994
UMC (effective 2/23/96) and 1993 NEC (effective 12/28/95)
The above regulations apply to residential construction, regardless of the code editions
adopted by ordinance
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3,
1994 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law
To speed up the recheck process, please note on this list for a copy) where each
correction item has been addressed, i e . plan sheet number, specification section, etc
Be sure to enclose the marked up list when you submit the revised plans
LIST NO 1 GENERAL SINGLE FAMILY DWELLINGS AND DUPLEXES WITHOUT SUPPLEMENTS (1994 UBC) r3forwdot
Carlsbad 98-2821
9/10/98
1 Please make all corrections on the original tracings, as requested in the
correction list
Submit three sets of plans for commercial/industrial projects (two sets of plans for
residential projects) For expeditious processing, corrected sets can be submitted
in one of two ways
1 Deliver all corrected sets of plans and calculations/reports directly to the City
of Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA 92009,
(760) 438-1161 The City will route the plans to EsGil Corporation and the
Carlsbad Planning, Engineering and Fire Departments
2 Bring one corrected set of plans and calculations/reports to EsGil
Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (619) 560-
1468 Deliver all remaining sets of plans and calculations/reports directly to the City
of Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments
NOTE Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete
2 All sheets of plans must be signed by the person responsible for their preparation
(California Business and Professions Code)
3 Please show on the floor plan the adjacent room to the proposed addition Please
dimension the room and show the size of the openable windows so as to verify the
area of required light and ventilation has not been reduced by the proposed
addition
4 When the valuation of a room addition or repair exceeds $1,000, or when sleeping
rooms are created, smoke detectors shall be provided, except that smoke detectors
added at existing construction need only be battery powered Section 310 9 1 2
Please show or note on the plans that smoke detectors will be installed m all
existing bedrooms and the hallways leading to the bedrooms
5 Dimension on the plans 30" clear width for water closet compartments and 24"
clearance in front of water closet Section 2904
6 Please show glazing in the following locations to be of safety glazing material
(Tempered Glass) in accordance with Section 2406 4 (see exceptions)
7 Fixed and sliding panels of sliding door assemblies and panels in swinging doors other
than wardrobe doors
8 Fixed or operable panels adjacent to a door where the nearest exposed edge of the
glazing is within a 24-inch arc of either vertical edge of the door in a closed position and
where the bottom exposed edge of the glazing is less than 60 inches above the walking
surface
Carlsbad 98-2821
9/10/98
9 Individual fixed or operable panels, other than those locations described above, that
meet all of the following conditions
• Exposed area of an individual pane is greater than 9 square feet, and
• Exposed bottom edge is less than 18 inches above the floor, and
• Exposed top edge is greater than 36 inches above the floor, and
• One or more walking surfaces are within 36 inches horizontally of the plane of the
glazing
10 Specify on the plans the following information for the roof materials, per Section
10633
• Manufacturer's name
• Product name/number
• ICBO approval number, or equal
11 Provide skylight details to show compliance with Sections 2409 and 2603, or specify
on the plans the following information for the skylight(s), per Section 106 3 3
• Manufacturer's name
• Model name/number
• ICBO approval number, or equal
• Dimension the size of the skylight on the plans
12 Note on plans that wood shall be 6" minimum above finish grade Section 1806 1
13 Note on plans that surface water will dram away from building and show drainage
pattern and key elevations Section 1804 7
14 Please show concrete/permanent landings at the outside of the new exterior doors
The landing must be as wide as the door and a minimum of 36" in the direction of
travel
15 Please dimension the location of the isolated pier footing to support the glu lam on
the foundation plan
16 Please revise the plans to show the isolated pier footing to be a minimum of 5 sqft
or 24x30x12 in size for the beam load and the tributary hip/rafter loads
17 Please attach to the plans the accompanying Minimum Construction Specifications
that include UBC nailing schedules etc
18 Note on the plans that an A I T C Certificate of Compliance for glued laminated
wood members shall be given to the building inspector prior to installation Section
2305
19 Please show on the plans the exterior wall covering material
20 Please show on the plans the size of all headers
Carlsbad 98-2821
9/10/98
21 Show wall bracing Every exterior wood stud wall and main cross-stud partition shall
be braced at each end within 8'-0" and at least every 25 feet of length Section
2326 11 3 and Table 23-l-W Please show the braced wall length or alternate
braced wall length and requirements from UBC Section 2326 11 4 on the plans or
provide design and calculations from a licensed Engineer or Architect for the lateral
analysis of the structure proposed and have the Engineer or Architect stamp seal
with expiration date and sign the calculations and the structural sheets of the plans
22 Please show straps on the top of the framing members at the ridge and hip
connection
23 Note on the plans that the FAU closet or alcove must be 12 inches wider than the
furnace or furnaces being installed UMC Section 315 1
24 Show minimum 30" deep unobstructed working space in front of furnace controls
Section 305 2, UMC
25 Please show the input Btu/hr rating of the FAU and the size and the location of the
required combustion air openings for the proposed FAU
26 Show on the plan that ground-fault circuit-interrupter protection complies with 1993
NEC Art 210-8, which reads as follows
• All 125-volt, single-phase, 15- and 20- ampere receptacles installed in bathrooms,
outdoors and within 6 feet of a kitchen sink
27 Provide a note on the plans for the exterior shower In showers and tub-shower
combinations, control valves must be pressure balanced or thermostatic mixing
valves UPC Section 4107
28 Provide plans, calculations and worksheets to show compliance with current energy
standards
29 The regulations require a properly completed and properly signed Form CF-IR to be
either imprinted on the plans, taped to the plans or "sticky backed" on the
plans, to allow the building inspector to readily compare the actual construction with
the requirements of the approved energy design
30 All energy items shown on the plans must be in agreement with the information
shown on the properly completed Form CF-IR Please show the required insulation
values for wall and ceilings on the plans
31 Specify on the building plans all of the mandatory energy conservation requirements
as listed on the enclosure titled, "Mandatory Measures Checklist"
Carlsbad 98-2821
9/10/98
32 Provide fluorescent general lighting (40 lumens per watt minimum) in kitchen(s) and
bathrooms
33 Provide a note on the plans stating "All new glazing (fenestrations) will be installed
with a certifying label attached, showing the U-value "
To speed up the review process, note on this list (or a copy) where each correction
item has been addressed, i e , plan sheet, note or detail number, calculation page,
etc
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list If there are other changes, please briefly describe
them and where they are located in the plans
Have changes been made to the plans not resulting from this correction list? Please
indicate
Yes Q No a
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123, telephone number of 619/560-1468,
to perform the plan review for your project If you have any questions regarding
these plan review items, please contact Mike Puckett at Esgil Corporation
Thank you
Carlsbad 98-2821
9/10/98
/9£ 32 Provide fluorescent general lighting (40 lumens per watt minimum) in kttchen(s) and
bathrooms
A- (Q 33 Provide a note on the plans stating "All new glazing (fenestrations) will be installed
with a certifying label attached, showing the U-value "
To speed up the review process, note on this list (or a copy) where each correction
item has been addressed, i e , plan sheet, note or detail number, calculation page,
etc
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list If there are other changes, please briefly describe
them and where they are located in the plans
Have changes been made to the plans not resulting from this correction list? Please
No
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123. telephone number of 619/560-1468,
to perform the plan review for your project If you have any questions regarding
these plan review items, please contact Mike Puckett at Esgii Corporation
Thank you
MINIMUM CONSTRUCTION SPECIFICATIONS
These are minimum specifications established by the Uniform Building Code These specifications apply in the absence of more restrictive specifications in the approved
plans Code sections listed refer to the 1994 edition of the UBC ^
I FOUNDATION AND UNDERFLOOR
1 Concrete Strength Concrete for footings must have a
minimum compressive strength of 2500 psi at 28 days and
composed of 1 part cement, 2 1/2 parts sand, 3 1/2 parts of
3/4" maximum size rock with not more than 7 gallons of
water per sack of cement
2 Wood and Earth Separation Foundations supporting
wood must extend at least 6" above the adjacent finish
grade [UBC Section 1806 1] Provide 18" clearance under
wood joists and 12" clearance under wood girders which are
not pressure treated [UBC Section 2317 3]
3 Concrete Slabs Slabs on grade must be at least 3 1/2"
thick [UBC Section 1924]
4 Treated Wood All foundation plates or sills and sleepers
on concrete or masonry which is in direct contact with earth
must be pressure-treated wood or foundation grade
redwood Wood joists closer than 18", or wood girders or
supports closer than 12" to the ground, must be pressure
treated [UBC Section 2317 4]
5 Anchor Bolts and Footing Sills All sills must have full
bearing on the footing wall or slab and must be bolted to the
foundation with 1/2" nominal diameter steel bolts embedded
at least 7" into the concrete or reinforced masonry or 15"
into unreinforced grouted masonry Bolts must be spaced
not to exceed 6" on center There must be 2 bolts per piece
with bolts not over 12" from cut end of sills [UBC Section
18066]
6 Underfloor Vents Underfloor areas must be ventilated by
openings in foundation walls Wall openings must have a
net area of not less than 1 sq ft for each 150 sq ft of
underfloor area Openings must be arranged to provide
cross ventilation and must be covered with corrosion-
resistant wire mesh with openings of 1/4-inch in dimension
[UBC Section 2317 7]
7 Underfloor Access Underfloor areas must be provided
with an unobstructed crawl hole not less than 18" x 24"
Openings must be effectively screened or covered [UBC
Section 2317 3]
II WOOD FRAMING
1 Lumber All joist, rafters, beams, and posts 2" to 4" thick
must be No 2 Grade Douglas Fir-Larch or better All posts
and beams 5" and thicker must be No 1 Grade Douglas Fir-
Larch or better (See item 13 in this section for lumber
grading requirements for studs )
2 Wall bracing Every exterior wood stud wall and main
cross partitions must be braced at each end and at least at
every 25 feet of length with 1 x 4 diagonal let-in braces or
equivalent [UBC Section 2326 11 3,2326 11 4, Table 23-
I-W]
3 Lateral Support Floor joists and rafters more than 10" in
depth and spanning more than 8 feet must be supported
laterally by bridging or solid blocking at intervals not
exceeding 8 feet [UBC Section 2306 7]
4 Blocking Provide blocking at ends and at supports of floor
joists, and for rafters at exterior walls "[UBC Section
2326 8 6]
5 Roof Blocking Provide 2" full depth solid blocking at
ridge line and at exterior walls on trussed roofs [UBC
Section 2326 128]
6 Double Joists Floor joists must be double under bearing
partitions running parallel with the joists [UBC Section
2326 8 5]
7 Rafter Purlin Braces Purlin braces shall be not less than
45 degrees to the horizontal [UBC Section 2326 12 7]
8 Rafter Ties Rafter ties must be spaced not more than 4
feet on center where rafters and ceiling joists are not
parallel [UBC Section 2326 12 6]
9 Clearance Provide 1/2" minimum clearances between top
plate of interior non-beanng partitions and bottom chord o!
trusses
10 Top Plate Provide double top plate with minimum 48" laj
splice [UBC Section 2326 11 2]
11 Nailing -Nailing-shall be in compliance with UBC Tab!
23-I-Q A copy of this table is reproduced on page 4
12 Fire Blocks Fire blocks must be provided for walls r
ceilings, floor levels and concealed spaces at 10' oc
horizontally [UBC Section 708 2 1]
13 Studs In one and two story buildings, studs for extenc
walls and interior bearing walls must be not less than 2"x<!
at 16" o c Studs for interior non-bearing partitions may t
2"x3" at 16" o c Studs 2" to 4" thick, 2" to 4" wide and n
more than 8 feet long must be "stud grade" Douglas i
Larch or better when supporting not more than one flo
and a roof Studs for beaaring walls must not exceed 8 fe
m height [UBC Section 2326 11 1, Table 23-I-R-3]
14 Laminated Wood An AITC Certificate of Conforman
for glued laminated wood members must be given to t
it/96
1 of
CM
Building Inspector prior to their installation [UBC Section
2305]
III GENERAL MATERIAL SPECIFICATIONS
1 Mortar Mix Mortar to be used for construction of
masonry walls, foundation walls and retaining walls must be
1800 psi minimum and may consist of 1 part Portland
cement, 3 1/2 parts sand, and 1/4 part hydrated lime or lime
putty Plastic cement may be used with 1 part plastic
cement to 2 1/4 to 3 parts sand [UBC Table 21-A, UBC
Standard 21-15]
2 Grout Mix The mix for the grout may be 1 part Portland
cement, 3 parts sand, 1/10 part hydrated lime or lime putty,
1 to 2 parts pea gravel (3/8" maximum) Water added to
pouring consistency without segregation of grout
constituents [UBC Table 21-B] The use of plastic cement
is not allowed for grout [UBC Section 2103 5]
3 Masonry The masonry units must comply with ASTM
Spec C90-75, Grade N for hollow unit concrete blocks
[UBC Standard 21-4]
4 Structural Steel Steel used as structural shapes such as
wide flange sections, channels, plates and angles must
comply with ASTM Spec A-36 Pipe columns must
comply with ASTM Spec A-53 [UBC Standard 22-1]
IV ROOFING AND WEATHERPROOFING
1 Wood Siding AH wood siding must be placed over an
approved, weather-resistive barrier [UBC Section 1402 1]
2 Flashing Around Openings Every opening in any exterior
wall must be flashed with sheet metal or waterproof
building paper [UBC Section 1402 2 Building Newsletter
17-2]
3 Roof Covering Mineral-surfaced, built-up roofing must
not be installed on roof having a pitch greater than 3 inches
to 12 inches The following are minimum pitches
composition shingles minimum 2 inches to 12 inches,
wood shingles minimum 3 inches to 12 inches, wood
shakes minimum 4 inches to 12 inches, roofing tile
minimum 2Vi inches to 12 inches, clay or concrete roofing
VI TABLES
tile minimum 4 inches to 12 inches Wood shingles and
wood shakes must be pressure-impregnated with chemicals
to obtain a Class C rating [UBC Section 1504 and Tables
15-B-l, 15-B-2, and 15-D-l]
4 Weep Screed A weep screed must be provided at the
foundation plate line for all weather-exposed exterior stud
walls finished on the exterior with stucco [UBC Section
2506 5]
5 Basement Walls Basement foundation walls below grade
must be damp-proofed on the outside [UBC Sectior
1402 4]
V GENERAL
1 Attic Access Attic areas over 30" high must be accessible
by an opening not less than 22" x 30" With a furnace in the
attic, the opening must not be less than 30" x 30" [UBC
Section 1505 1, UMC Section 319 3]
2 Shower Enclosures Shower walls must be finished to z
height of 70" above the drain inlet with a smooth, hard, non
absorbent surface [UBC Section 807 1 3]
3 Electric Meter Enclosure Contact San Diego Gas &
Electric Company, Customer Extension Planning
Department, for meter location All wiring must comph
with the 1993 National Electrical Code
4 Smoke Detectors In new construction, smoke detector
must receive their primary power from the building wiring
when such wiring is served from a commercial source
Smoke detectors may be battery-operated when installed L
existing buildings, buildings without commercial power, o
building which undergo alterations, repairs or addition
regulated by UBC Section 3109 In dwelling units,
detector shall be installed in each sleeping room ant
centrally located in the corridor or area giving access I
each separate sleeping area, in each story and in th
basement Where the ceiling height of a room open to th
hallway serving the bedrooms exceeds that of the hallwa
by 24" or more, smoke detectors shall be installed in th
hallway and the adjacent room Detectors shall sound a
alarm audible in all sleeping rooms [UBC Section 310 S
TABLE I8-I D FOUNDATIONS FOR STUD BEARING \YALLS, MIMMUM REQUIREMENTS1-"
Number of Floors Supported
by the Foundation*
I
2
3
Thickness of Foundation Wall (inches)
Concrete
6
8
10
Unit Masonry
6
8
10
Width of Footing
(inches)
12
15
18
Thickness of Footing
(inches)
6
7
8
Depth Below Undisturbed
Ground Surface (inches)
12
IS
24
'Vvhere unusual conditions or frost conditions are found, lootings and foundations shall be as required in Section 1806 I
2The ground under the floor may be excavated to the elevation of the top of the footing
'Interior stud bearing walls may be supported by isolated footings The footing width and length shall be twice the width shown in this table and the footings shall
spaced not more than 6 feet on center
'Foundations may support a roof in addition to the stipulated number of floors Foundations supporting roofs only shall be as required for supporting one floor
CM
2 of
TABLE 23-I-Q NAILING SCHEDULE
CONNECTION
I Joist to sill or girder toenail
2 Bridging to joist, toenail each end
3 1 "x6" subfloor or less to each joist, face nail
4 Wider than I"x6" subfloor to each joist, face nail
5 2" subfloor to joist or girder, blind and face nail
6 Sole plate to joist or blocking typical face nail
Sole plate to joist or blocking at braced wall panels
7 Top plate to stud, end nail
8 Stud to sole plate
9 Double studs face nail
10 Doubled top plates, typical face nail
Doubled top plates lap splice
" 1 1 Blocking between joists or rafters to top plate toenail
12 Rim joist to top plate toenail
13 Top plates laps and intersections face nail
14 Continuous header two pieces
15 Ceiling joists to plate toenail
16 Continuous header to stud toenait
17 Ceiling joists laps over partitions face nail
18 Ceiling joists to parallel rafters face nail
19 Rafter to plate toenail
20 I "brace to each stud and plate face nail
21 I"x8" sheathing or less to each bearing face nail
22 Wider than Px8" sheathing to each bearing face nail
23 Built-up corner studs
24 Built-up girder and beams
25 2" planks
26 Wood structural panels and particleboard ]
Subfloor, roof and wall sheathing (to framing)
'/a" or less
9/32"-1/."
%"-l"
IV4M1/."
Combination subfloor underlayment (to framing)
'/." and less
%"-!•
1VV-11/."
27 Panel siding (to framing)
W or less
«/4"
28 Fiberboard sheathing '
Vi"
25/32"
29 Interior paneling
'/,"
%"
NAILING1
3 8d
2 8d
28d
3 8d
2 I6d
16dat 16" oc
3-I6dper 16"
2 16d
4 8d toenail or 2 16d, end nail
16dat24"oc
16datl6"oc
8-16d
" ' - 3-8d
8d at 6" o c
2 16d
I6d at 16" o c along each edge
38d
4-8d
3 16d
3-16d
3 8d
2 8d
28d
38d
16dat24"oc
20d at 32" o c at top and bottom and staggered 2-20d at ends and at each splice
2-1 6d at each bearing
6d>
8d4 or 6d5
8d5
10d'or8ds
6d*
8dJ
lOd'orSd5
6d4
8d*
No llga-1
6d4
No 16ga.'
No 1 1 ga.' I
8d'
No 16 ga.*
4d10
6d"
4/96 CM
3 of 4
1AULE 23 I Q NAILING SCHEDULE (CONTINUED)
"Common or box nails may be used except where otherwise staled
'Nails spaced at 6 inches on center at edges 12 inches at intermediate supports except 6 inches at all supports where spans are 48 inches or more For nailing of wood
structural panel and particleboard diaphragms and shear walls refer to Section 2314 3 Nails for wall sheathing may be common box or casing
'Common or deformed shank
'Common
'Deformed shank
"Corrosion resistant siding or casing nails conforming to the requirements of Section 2325 I
'Fasteners spaced 3 inches on center at exterior edges and 6 inches on center at intermediate supports
•Corrosion-resistant roofing nails with 7/16-mch-diamcter head and 1 '/i-inch length for '/i-mch sheathing and IV. inch length for 25/32 inch sheathing conforming to the
requirements of Section 2325 1
'Corrosion resistant staples with nominal 7/16 inch crown and lV4-tnch length for'/: inch sheathing and I'/i-inch length for 25/32 inch sheathing conforming to the
requirements of Section 2325 I
'"Panel supports at 16 inches [20 inches if strength axis in the long direction of the panel unless otherwise marked] Casing or finish nails spaced 6 inches on panel edges
12 inches at intermediate supports
"Panel supports at 24 inches Casing or finish nails spaced 6 inches on panel edges 12 inches at intermediate supports
TABLE 23-I-S-l - ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANEL SHEATHING AND SINGLE-FLOOR GRADE CONTINUOUS
OVER TWO OR MORE SPANS WITH STRENGTH AXIS PERPENDICULAR TO SUPPORTS1-1
Sheathing Grades
Panel Span Rating
Roof/Floor Span
12/0
16/0
20/0
24/0
24/16
32/16
40/20
48/24
54/32
60/48
Pane!
Thickness (inches)
5/16
5/16%
5/16%
%,7/I6'/J
7/16 '/,
15/32 '/>,%
19/32 %,'/«%
23/32 >/« %
%1
% 1 1V4
Single-Floor Grades
Panel Span Rating
(inches)
16 oc
20 oc
24 oc
32 oc
48 oc
Panel Thickness
(inches)
'/i, 1 9/32%
19/32%%
23/32 %
%,!
13/32 1%
RooP
Maximum Span (inches)
With Edge
Support
12
16
20
24
24
32
40
48
54
60
Without Edge
Support
12
16
20
20'
24
28
32
36
40
48
Load5 (pounds per sq ft )
Total
Load
40
40
40
40
50
40
40
45
45
45
Live Load
30
30
30
30
40
30
30
35
35
35
RooP
Maximum Span (inches)
With Edge
Support*
24
32
48
48
60
Without Edge
Support
24
43
36
40
48
Load1 (pounds per sq ft)
Total
Load
50
40
35
50
50
Live Load
40
30
2i
40
50
Floor4
Maximum Span (inches)
0
0
0
0
16
16l
20"
24
32
48
Floor4
Maximum Span (inches)
16'
20"
24
32
48
'Applies to panels 24 inches or wider
Floor and roof sheathing conforming with th s table shall be deemed to meet the design criteria of Section 2321
'Uniform load deflection limitations 1/180 of span under live load plus dead load 1/240 under live load only
'Panel edges shall have approved tongue and groove joints or shall be supported with blocking unless'/«inch minimum thickness undcrlayment or l'/j inches of approv
cellular or lightweight concrete is placed over the subfloor or finish floor is'/«inch wood strip Allowable uniform load based on deflection of 1/360 of span is 100 poun
per square foot (psf) except the span rating of 48 inches on center is based on a total load of 65 psf
'Allowable load at maximum span
Tongue and groove edges, panel edge clips [one midway between each support, except two equally spaced between supports 4S inches on center] lumber blocking
other Only lumber blocking shall satisfy blocked diaphragms requirements
'For '/> inch panel maximum span shall be 24 inches
'May be 24 inches on center where '/4-inch wood strip flooring is installed at right angles to joist
*May be 24 inches on center for floors where 1 '/i inches of cellular or lightweight concrete is applied over panels
4/96CM
t of it
Certificate of Compliance: Residential (Page 1 of 2) CF-1R
Project Tllle
Project Address
Documentation Author Telephone
Compliance Method (Package Point System or Computer) Climate Zone
Date
Building Permit *
Plan Check / Date
Field Check / Date
Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area ft2
Building Type Single Family Addition
(check one or more) Multi-Family Existmg-Plus-Addrtion
Front Orientation North / East / South / West / All Orientations
(Input orientation in degrees and cirde one )
Number of Dwelling Units
Floor Construction Type Slab / Raised Floor (circle one or both)
BUILDING SHELL INSULATION
Component Insulation
Type R-Value
Construction
Assembly
U-Value
Location/Comments
(attic, to garage, typical, etc )
Wall
Wall
Roof
Roof
Floor
Floor
Slab Edge
FENESTRATION Shading Devices
Fenestration Area Fenestration Interior Exterior Overhang Framing Type
Orientation (sf) _ U-Value _ (roller blind, etc ) (shadescreen, etc ) (yes/no) (metal/wood/vinyl)
Front ( ) _ _ _ _ _ _
Front ( ) _ _ ~~~~~ _Left ( ) • "
Rear ( )
Rear ( )
Right ( )
R'Qht ( )
Skylight
Skylight
THERMAL MASS
Type/Covering Area Thickness
(slab/exposed, tile etc) (sf) (inches) Location/Description (kitchen bath etc)
R»vls«d January 1992
Certificate of Compliance: Residential (Page 2 of 2)CF-1R
Project Title Date
HVAC SYSTEMS
Note Input hydronic or combined hydronic data under Water Heating Systems except Design Heating Load
Distribution
Heating Equipment Minimum Type and Duct or
Type (furnace, heat Efficiency Location Piping Thermostat
pump, etc ) (AFUE/HSPF) (ducts/attic etc ) R-Value Type
Cooling Equipment
Type (air conditioner,
heat pump evap cooling)
Minimum
Efficiency
(SEER)
Duct
Location
(attic, etc )
Duct
R-Value
Thermostat
Type
Configuration
(split or package)
WATER HEATING SYSTEMS
Water Heater Distribution
Type Type
Rated1
Number Input (kW
in System or Btu/hr)
Tank
Capacity
(gallons)
Energy1
Factor or
Recovery
Efficiency
External
Tank
Standby Insulation
Loss (%) R-Value
1 For small gas storage (rated input £ 75 000 Btu/hr) electric resistance and heat pump water heaters list Energy Factor
For large gas storage water heaters (rated input > 75 000 Btu/hr) list Rated Input, Recovery Efficiency and Standby Loss
For Instantaneous gas water heaters, list Rated Input and Recovery Efficiency
SPECIAL FEATURES/REMARKS (Add extra sheets if necessary)
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of
the California Code of Regulations, and the administrative regulations to implement them This certificate has been signed by the
individual with overall design responsibility When this certificate of compliance is submitted for a single building plan to be built in multiple
orientations, any shading feature that is varied is indicated in the Special Features/Remarks section
Designer Or Owner (per Business & Professions Code)
Name
Title/Firm
Address
Telephone
Lie #
Documentation Author
Name
Title/Firm
Address
Telephone
(signature)
Enforcement Agency
Name
Title
Agency
Telephone
(date)(signature)(date)
(signature/stamp)
R«vis*d January 1992
(date)
Mandatory Measures Checklist. Residential MF-1R
NOTE Lownse residential buildings subject to the Standards must contain these measures regardless of the compliance
approach used Items marked with an asterisk (") may be superseded by more stringent compliance requirements
listed on the Certificate of Compliance When this checklist is incorporated into the permit documents the features
noted shall be considered by all parties as binding minimum component performance specifications for the
mandatory measures whether they are shown elsewhere in the documents or on this checklist only
DESCRIPTION DESIGNER ENFORCEMENT
Building Envelope Measures
* §150(a) Minimum R 19 ceiling insulation
§150(b) Loose fill insulation manufacturer s labeled R Value
* §150(c) Minimum R 13 wall insulation in framed walls (does not apply to extenor mass walls)
* §150(d) Minimum R 13 raised floor insulation in framed floors, minimum R 8 in concrete raised floors
§150(1) Slab edge insulation water absorption rate no greater than 0 3%. water vapor transmission rate no
greater than 2 0 perm/inch
§ 118 Insulation specified or installed meets California Energy Commission quality standards
Indicate type and form
§116-17 Fenestraticn Products, Exterior Doors and Infiltration/Exfiltration Controls
a Doors and windows between conditioned and unconditioned spaces designed to limit air leakage
b Manufactured fenestratoon products have label with certified U value, and infiltration certification
c Exterior doors and windows weatherstripped, all pints and penetrations caulked and sealed
§ 1 S0(g) Vapor ba/ners mandatory in Climate Zones 14 and 16 only
§150(0 Special infiltration barrier installed to comply with §151 meets Commission quality standards
§150(e) Installation of Fireplaces, Decorative Gas Appliances and Gas Logs
1 Masonry and factory built fireplaces have
a. Closeable metal or glass door
b Outside air intake with damper and control
c Rue damper and control
2 No continuous burning gas pilots allowed
Space Conditioning, Water Heating and Plumbing System Measures
§110-13 HVAC equipment, water heaters showerheads and faucets certified by the Commission
§150(i) Setback thermostat on all applicable heabng systems
§ 150(j) Pipe and Tank Insulation
1 Indirect hot water tanks (e g, unfired storage tanks or backup solar hot water tanks) have insulation
blanket (R 12 or greater) or combined intenor/extenor insulation (R 16 or greater)
2 First 5 feet of pipes closest to water heater tank, non rearculabng systems, insulated (R 4 or greater)
3 All buried or exposed piping insulated in rearculafing sections of hot water system
4 Cooling system piping below 55°F insulated
5 Piping insulated between heating source and indirect hot water tank
"•§150(m) Ducts and Fans
1 Ducts constructed, installed and sealed to comply with UMC Sections 1002 and 1004, ducts insulated
to a minimum installed value of R 4 2 or ducts enclosed entirely within conditioned space
2 Exhaust fan systems have backdraft or automatic dampers
3 Gravity ventilating systems serving conditioned space have either automatic or readily accessible,
manually operated dampers
§114 Pool and Spa Heating Systems and Equipment
1 System is certified with 78% thermal efficiency, on off switch, weatherproof operating instructions,
no electric resistance heabng and no pilot light
2 System is installed with
a At least 36* pipe between filter and heater for future solar heating
b Cover for outdoor pools or outdoor spa
3 Pool system has directional inlets and a circulation pump time switch
§115 Gas fired central furnace, pool heater, spa heater or household cooking appliance have no
continuously buring pilot light (Exception Non electrical cooking appliance with pilot < 150 Btu/hr)
Lighting Measures
§150(k) 40 lumens/watt or greater for general lighting in kitchens and rooms with water dosets, and
recessed ceiling fixtures 1C (insulation cover) approved
Revised January 1992
City of Carlsbad
Engineering Department
DATE
BUILDING ADDRESS
PROJECT DESCRIPTION
ASSESSOR'S PARCEL NUMBER
BUILDING PLANCHECK CHECKLIST
PLANCHECK NO CB
^9 \0 //>rf^ W
~ \4A -
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved The approval is based on plans,
information and/or specifications provided in your
submittal therefore any changes to these items after
this date including field modifications must be
reviewed by this office to insure continued
conformance with applicable codes Please review
carefully all comments attached as failure to comply
with instructions in this report can result in
suspension of permit to build
A Right-of-Way permit is required prior to
construction of the following improvements
EST VALUE
DENIAL
Please see the attached report of deficiencies
marked with D Make necessary corrections to plans
or specifications for compliance with applicable
codes and standards Submit corrected plans and/or
specifications to this office for review
B^/k^^/.f^te
*fi
(/<
By Date
By \
FOR OFFICIAL USE ONLY
ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT
Date
ATTACHMENTS
Dedication Application
Dedication Checklist
Improvement Application
Improvement Checklist
Future Improvement Agreement
Grading Permit Application
Grading Submittal Checklist
Right-of-Way Permit Application
Right-of-Way Permit Submittal Checklist
and Information Sheet
Sewer Fee Information Sheet
ENGINEERING DEPT CONTACT PERSON
Name Danna Trigs
City of Carlsbad
Address 2075 Las Palmas Dr Carlsbad CA 92009
Phone (619)438-1161 ext 4374 _
CFD INFORMATION
Parcel Map No _
Lots
Recordation
Carlsbad Tract
A-4
UOCSOjKLiiIVBuilding tJancheck Uklsl HKUUU1 HormLII doc *
2075 Las Palmas Dr • Carlsbad, CA 920O9-1576 • (76O) 438-1161 • FAX (760)
BUILDING PLANCHECK CHECKLIST
1 Provide a fully dimensioned site plan drawn to scale Show
^.... .rrow \3r Property Lines
istmg & Proposed Structures -vE-^Easements
istmg Street Improvements 'F^^Rjght^of-Way Width & Adjacent Streets
^-^Dnveway widths
'ow on site plan
Drainage Patterns
{^^* Building pad surface drainage must maintain a minimum slope of one
percent towards an adjoining street or an approved drainage course
2 ADD THE FOLLOWING NOTE "Finish grade will provide a minimum positive
drainage of 2% to swale 5' away from building "
B Existing & Proposed Slopes and Topography
3 Include on title sheet
4/teaddress
's Parcel Number
Description
For commercial/industrial buildings and tenant improvement projects, include
total building square footage with the square footage for each different use,
existing sewer permits showing square footage of different uses (manufacturing,
warehouse, office, etc ) previously approved
EXISTING PERMIT NUMBER DESCRIPTION
DISCRETIONARY APPROVAL COMPLIANCE
4a Project does not comply with the following Engineering Conditions of approval for
Project No
Q 4b All conditions are in compliance Date
H \WORD\DOCS\CHKLST\Buildmg Plancheck Cklsl BP0001 Forni DT doc
BUILDING PLANCHECK CHECKLIST
-i st/ 2nd^ 3rdv^
Q Q Q 9 A SEWER PERMIT is required concurrent with the building permit issuance The
fee is noted in the fees section on the following page
Q Q Q 10 INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad
sewer service area, you need to contact the Carlsbad Municipal Water District,
located at 5950 El Camino Real, Carlsbad, CA 92008 District personnel can
provide forms and assistance, and will check to see if your business enterprise is
on the EWA Exempt List You may telephone (760) 438-2722, extension 153, for
assistance
Industrial Waste permit accepted by
Date
11 NPDES PERMIT
Complies with the City's requirements of the National Pollutant Discharge
Elimination System (NPDES) permit The applicant shall provide best
management practices to reduce surface pollutants to an acceptable level prior to
discharge to sensitive areas Plans for such improvements shall be approved by
the City Engineer prior to issuance of grading or building permit, whichever
occurs first
Q Q Q 12 Q Required fees are attached
Q No fees required
Q Q Q 13 Additional Comments
H \WORD\DOCSVCHKLS~nBuildmri Planctieck Cklsl BP0001 Form DT doc
CT
to!
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No CB
Planner
APN
Address
Phone (619) 438-1161, extension
Type of Project & Use
Zoning
CFD
Circle One
General Plan
.Date of participation
Net Project Density
Facilities Management Zone
DU/AC
Remaining net dev acres
(For non-residential development Type of land used created by
this permit )
Leoend X Item Complete
Environmental Review Required
DATE OF COMPLETION
Item Incomplete - Needs your action
YES NO X' TYPE '
Compliance with conditions of approval7 If not, state conditions which require action
Conditions of Approval
Discretionary Action Required
APPROVAL/RESO NO
PROJECT NO
YES _ NO
_ DATE
TYPE
OTHER RELATED CASES
Compliance with conditions or approval7 If not, state conditions which require action
Conditions of Approval
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone7 YES NO
CA Coastal Commission Authonty7 YES NO
If California Coastal Commission Authority Contact them at - 3111 Cammo Del Rio North, Suite
200 San Diego CA 92108-1725, (619) 521-8036
Determine status (Coastal Permit Required or Exempt)
Coastal Permit Determination Form already completed7 YES NO
If NO complete Coastal Permit Determination Form now
Coastal Permit Determination Log #
Follow-Up Actions
1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum
Floor Plans)
2) Complete Coastal Permit Determination Log as needed
D Inclusionary Housing Fee required YES
(Effective date of Inctusionary Housing Ordinance May 21 1993)
*L_
Data Entry Completed7 YES NO
(Enter CB if UACT NEXT12 Construct housing Y/N Enter Fee Amount (See tee schedule tor amount! Return
Site Plan
| | 1 Provide a fully dimensional site plan drawn to scale Show North arrow
property lines, easements, existing and proposed structures, streets existing
street improvements, right-of-way width, dimensional setbacks and existing
topographical lines
[~~] | | 2 Provide legal description of property and assessor's parcel number
Zoning
/j_J M | | 1 Setbacks
Front Required «£0 Shown «2 a
S(?c, j^4d -^Interior Side F
y>j(oi>S ' Street Side F
lequired S' Shown 5 '
lequired | Shown
Rear Required £-6 '_ Shown >&" <£/0 f
/ {
£_ 2 Accessory structure set
/
backs t//x,
/ Front Required Shown
Interior Side Required Shown
Street Side Required Shown
Rear Required Shown
Structure separation Required Shown
f J\ytf 3 Lot Coverage Required 4rO°/a ^^VT- Shown *s£B/t
K, /
A/-3 fto^n^ 4 /rf- *ze-- ^ ^^J
j\ 4 Height Required "£0 W0s{ Shown 13
J( 1 1 5 Parking Spaces Required ^ C-&? Zffc Shown ^ C^- R&A.xk'/ /) • - — cr~ ~ 0
Guest Spaces Required Shown
;^~^1 X/ 1 \ ^[^ 1 1 Additional Comments
^.c^Ciiics tfrz h.
\L- i A. u ' JL A ' -4t •/^ ^-TAfctdt-hd/i w ^/ (
/ <y5i'f - j/ j_ A/ /
• ^ -«- -.
i&, Of rtd<tl£<d/l 4 ^'^cLtTto/i^ C^)o&">^
oi~ p&Ysn'-ffcc£ - r&^$<~ C,fertrT<i*
' fffr^'lfl l£fV>^-i' 6pf)
, 1 f : , V
iF &#•! 5/~ ^>f- f~DK- LAl l^/ /tltjj ^,Jj'J fyjtt I ' J-
/yt/ro i^u^i-i U&ir jp*£i'j>n, $£-&~_
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER 1%
si/ ~t DATE
/s
Mnv 16 199S 8 SBflM
j
I
I
i
1 ', ''1-ss i0 *i W > *Hj
<• » iD r:/
0
. 70 -<=?£>CUSTOM
J'
UN PIECES
t
1
:
—
si:
^ Q2M
^B^ 21B50 Iv
(90
i< 1 Mb M it.R »0.
iv HI . < o i n i .
mtifli nv, TA a
NO wrr
WHOL5SAL.C TIMBCR PRODUCTS inl,
IOX 848 COLTON, CA 82324 0461
IAIN ST GRAND TERRACE CA 92313
9) 783 0470 (213) 462-12G4
TAX (809) 783 9032
S
H"I
0
PO MUMBBR VPNUME6H ' '
9? ^ *" o /&£&> <i
LENGTH DESCRIPTION
^dsr^.^^
PUP OHDRH NUMEEII
/
1 P XvCr / /7 y ^ts*~'\^*^'l_^ (j Co **
^^'
' 1
y/
^
FTG
LBp
MILLING
CTG
TAX
TOTAL
»iP '/?»
l^ 1
i i
|
i
1
Ii
Fid CK MATERIAL RECOVEO BY
X
~ • " TERMS 1% 1
_ _^ THIS IB AN AN
before your ne
Must be preset
CARTAGE
OATt
r *.' ->
£ ^ w £ w O
jZ&it
PICK UP DELW SH
FOOTAGE
3*
3»
TOTAL
PRICE
^
AMOUNT
Dth Net 11th ALL PAST DUE ACCOUNTS will be charged 1%% per month
ONUAL RATE OF 18% To avoid a charge your account must be paid in full
xt billing dato Check load with driver or no claim may be allowed Claims
ited within five days of receipt of materials Timbers manufactured to your
nay not be returned Handling to be charged on all returns
NOV 16 199B 9?00AM NO 077 P 2/3
Certificate of Conformance
Certificate^Q54A01
THIS IS TO CERTIFY that the glued laminated timber products Identified with a collective mark of
Engineered Wood Systems (IEWS) were manufactured In accordance with the applicable standards
and associated specifications indicated belowI
! ANSI Standard A190.1-1992, For Wood Products - Structural Glued
i Laminated Timber
i NER'488 Glued Laminated Timber Combinations And "GAP"
I Computer Program For Determining Design Stresses
AITC 117-93 - Manufacturing - Standard Specifications For Structural
Glued Laminated Timber Of Softwood Species
IT IS HEREBY; CERTIFIED that the APA EWStrademarked structural glued laminated timber members
were produced In a manufacturing facility subject to regular audits In accordance with the Engineered
Wood Syatetns (EW3) Quality Assurance Program Routine audits Include Inspection of the
manufacturing | process and evaluation of the In-plant QA program with adequate sampling to verify
conformance tp Industry standards for lumber grade and gluellne bond quality.
Thomas G, Williamson
Executive vice President
xa
SVaWEEffEP WOOD SYSTEM** a related oorpomflon of APA -
701 tSoulMBlri Street «PO B0xil700*Ttoomi WAM41I-0700
7W»phOft« (Z53) S65460Q • Pax Numwr, (263) 686-7285
NOV IS 199S 9?00flM NO 077 P 3/3
ENGINEERED WOOD SYSTPMS
ABAEWS
1 Attachment Number 1
Certificate of Coitformance Tto 05.440.1
f)> * /' / / //47/1 y/^ it A a (M.m&* f—(^—
Dated.
Job Mama
JoB location ^
Cuswnwi's Order No DM>
The tallowing identifies the members and gnes the basic specifications that were used on this job'
Lumber Species __COAST ?IR
Scat endi Camfaor
Mm
.WILLAMETTE INC.
MUI
AM6MOSM WOOD SYSTEMS - A flEWOT CORPORATION
City of Carlsbad
Building Department
CERTIFICATE OF COMPLIANCE
PAYMENT OF SCHOOL FEES OR OTHER MITIGATION
This form must be completed by the City and the appropriate school districts and returned to the City prior to
issuing a building permit The City will not issue any building permit without a completed school fee form
Project Name
Building Permit
Plan Check Number
Project Address
APN
Project Applicant
(Owner'(s') Name(s)
Project Description
Building Type
Residential
-ZALO A-
Number of New Dwelling Units
Square Feet of Living Area in New Dwelling
Second Dwelling Unit Square Feet of Living Area in SOU
Res Additions
Comerc / Ind
City Certification
Net Square Feet New Area
Square Feet Floor Area
K Date 1 Q{ tC[ V
SCHOOL DISTRICTS WITHIN THE CITY OF CARLSBAD
Carlsbad Unified School District
801 Pine Ave
Carlsbad CA 92009 (434-0661)
San Marcos Unified School Distnct
215MataWay
San Marcos, CA 92069 (736-2200)
Encmitas Union School District
101 South Ranch Santa Fe Rd
Encmitas, CA 92024 (944-4300)
San Dieguito Union High School District
710 Encmitas Blvd
Encmitas, CA 92024 (753-6491)
Certification of Applicant /Owners The person executing this declaration ("Owner") certifies under penalty of perjury that (1)
the information provided is correct and true to the best of the Owner s knowledge and that the Owner will file an amended
certification of payment and pay the additional fee if Owner requests an increase in the number of dwelling units or square
footage after the building permit is issued or if the initial determination of units or square footage is found to be incorrect
and that (2) the Owner is the owner/ developer of the above described project(s) or that the person executing this
declaration is authorized to sign on behalf of the Owner
Signature Date
2075 Las Palmas Dr • Carlsbad CA 92009-1576 - (760) 438-1161 - FAX (760) 438-O894
SCHOOL DISTRICT SCHOOL FEE CERTIFICATION
(To be completed by the school distnct(s))**********
SCHOOL DISTRICT REQUIREMENTS FOR THE PROJECT HAVE BEEN OR WILL BE SATISFIED
IN ACCORDANCE WITH ONE OF THE FOLLOWING (Check one )
Gov Code \
53080/65995 )
(AB181) J
Gov Code
65970
(SB 201)
Government
Code 53311
(Mello - Roos)
Prior Existing
Mitigation Agreement
Note
Exempt from
fee
requirements
(Indicate Date and Number or name of Agreement) |
Total amount of (new) floor area within the building
Fee Amount per Square Foot
Amount Collected
-Or if subject to Prior Existing Mitigation Agreement
For Detached Residential Dwelling Units or Attached Dwelling Units > 1600 Square Feet
Total Number of Dwelling Units
Amount per Dwelling Unit
Amount Collected
-and/or-
For Attached and Detached Dwelling Units < 1600 square feet/ per dwelling (If applicable)
Total Number of Dwelling Units
Amount per Dwelling Unit
Amount Collected
SCHOOL DISTRICT
This is to certify that the applicant listed on page 1 has paid all amounts or completed other applicable school
mitigation determined by the information presented above and due to the School District The City may issue
building permits for this project
SIGNATURE OF SCHOOL DISTRICT OFFICIAL
DATE
TITLE
PHONE NUMBER
NOTICE OF 90 DAY PERICte FOR'PROTESf OF FEES
The Carlsbad Unified School District has elected to imposed the fees and/or amounts herein upon a finding that those
facilities described in the School Impact Mitigation Fee Justification Study for Carlsbad Unified School Distnct, prepared by
David Taussig & Associates for the District Section 66020 of the Government Code enacted as Assembly Bill 3081, set
forth as Chapter 549, Statutes of the State of California, requires that all school districts, including the Carlsbad Unified and
the Encimtas Union School Districts, provide a written notice to the project applicant at the time of payment of the school
fees mitigation payments or other exaction This notice is to advise the project applicant that the protest period regard to
such amounts or the validity thereof in accordance with Section 66020 of the Government Code and other applicable law,
commences with such payment or performance of any other requirement as described in Section 66020 of the Government
Code Additionally, this notice advises that the protest thereof must occur within 90 calendar days thereafter
City of Carlsbad
Building Department
CERTIFICATE OF COMPLIANCE
PAYMENT OF SCHOOL FEES OR OTHER MITIGATION
This form must be completed by the City and the appropriate school districts and returned to the City prior to
issuing a building permit The City will not issue any building permit without a completed school fee form
Project Name
Building Permit
Plan Check Number
Project Address
APN
Project Applicant
(Owner'(s') Name(s)
Project Description
Building Type
Residential
/- He_
Number of New Dwelling Units
Square Feet of Living Area in New Dwelling
Second Dwelling Unit Square Feet of Living Area in SOU
Res Additions
Comerc / Ind
City Certification
Net Square Feet New Area
Square Feet Floor Area
Date | Q
SCHOOL DISTRICTS WITHIN THE CITY OF CARLSBAD
Carlsbad Unified School District
801 Pine Ave
Carlsbad CA 92009 (434-0661)
San Marcos Unified School District
215MataWay
San Marcos, CA 92069 (736-2200)
Encmitas Union School District
101 South Ranch Santa Fe Rd
Encmitas, CA 92024 (944-4300)
San Dieguito Union High School District
•710 Encmitas Blvd
Encmitas, CA 92024 (753-6491)
Certification of Applicant /Owners The person executing this declaration ("Owner") certifies under penalty of perjury that (1)
the information provided is correct and true to the best of the Owner's knowledge and that the Owner will file an amended
certification of payment and pay the additional fee if Owner requests an increase in the number of dwelling units or square
footage after the building permit is issued or if the initial determination of units or square footage is found to be incorrect,
and that (2) the Owner is the owner/ developer of the above described project(s), or that the person executing this
declaration is authorized to sign on behalf of the Owner
Signature Date//? .
2O75 Las Palmas Dr - Carlsbad CA 92OO9-1576 - (76O) 438-1161 - FAX (76O) 438-O894
SCHOOL DISTRICT SCHOOL FEE CERTIFICATION
(To be completed by the school distnct(s))
*************************************************!
SCHOOL DISTRICT REQUIREMENTS FOR THE PROJECT HAVE BEEN OR WILL BE SATISFIED
IN ACCORDANCE WITH ONE OF THE FOLLOWING (Check one )
Gov Code
53080/65995
(AB181)
/
Gov Code
65970
(SB 201)
Government
Code 53311
(Mello - Roos)
Prior Existing
Mitigation Agreement
Note
Exempt from
fee
requirements
| (Indicate Date and Number or name of Agreement)
to MS
4*1
Total amount of (new) floor area within the building
Fee Amount per Square Foot
Amount Collected
-Or if subject to Prior Existing Mitigation Agreement
For Detached Residential Dwelling Units or Attached Dwelling Units > 1600 Square Feet
Total Number of Dwelling Units
Amount per Dwelling Unit
Amount Collected
-and/or-
For Attached and Detached Dwelling Units < 1600 square feet/ per dwelling (If applicable)
Total Number of Dwelling Units
Amount per Dwelling Unit
Amount Collected
SCHOOL DISTRICT
This is to certify that the applicant listed on page 1 has paid all amounts or completed other applicable school
mitigation determined by the information presented above and due to the School District ^The City may issue
building permits for this project
SIGNATURE OF SCHOOL DISTRICT OFFICIAL
DATE
TITLE
PHONE NUMBER
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES
The Carlsbad Unified School District has elected to imposed the fees and/or amounts herein upon a finding that those
facilities descnbed in the School Impact Mitigation Fee Justification Study for Carlsbad Unified School District, prepared by
David Taussig & Associates for the District Section 66020 of the Government Code enacted as Assembly Bill 3081, set
forth as Chapter 549, Statutes of the State of California, requires that all school districts, including the Carlsbad Unified and
the Encimtas Union School Districts, provide a written notice to the project applicant at the time of payment of the school
fees mitigation payments, or other exaction This notice is to advise the project applicant that the protest period regard to
such amounts or the validity thereof in accordance with Section 66020 of the Government Code and other applicable law
commences with such payment or performance of any other requirement as descnbed in Section 66020 of the Government
Code Additionally this notice advises that the protest thereof must occur within 90 calendar days thereafter
. a
P> as Jl1^,"Ov d g.CvV
ro<o I
O
O
70
>