HomeMy WebLinkAbout2910 JEFFERSON ST; ; CBC2019-0558; PermitBuilding Permit Finaled
CCity of
Carlsbad
-- - - --------- -
Commercial Permit,
-
Print Date: 05/27/2020 Permit No: CBC2019-0558
Job Address: 2910 Jefferson St
Permit Type: BLDG-Commercial Work Class: Tenant Improvement Status: Closed - Finaled
Parcel No: 2033541300 Lot #: Applied: 12/03/2019
Valuation: $178,000.00 Reference #: - Issued: 02/05/2020
Occupancy Group: Construction Type PermitFinal
Close Out:
# Dwelling Units: Bathrooms: Inspector: MColl
Bedrooms: Orig. Plan Check #: Final
Plan Check U: Inspection: 05/27/2020
Project Title:
Description: ORANGE LAND HOLDINGS LLC: EXTERIOR SIDING IMPROVEMENTS, WINDOWS AND INSTALL ADA LIFT
Applicant: Owner: Contractor:
ORANGE LAND HOLDINGS LLC ORANGE LAND HOLDINGS LLC NORTH COUNTY CONSULTING INC
DON GLAUHORN
264 Pacific Ave 1204 2043 San Elijo Ave
SOLANA BEACH, CA 92075-0000 CARLSBAD, CA 92075 Cardiff by the Sea, CA 92007-1726
619-920-6564 - 858-799-0688
FEE AMOUNT
BUILDING PERMIT FEE ($2000+) $902.90
BUILDING PLAN CHECK FEE (BLDG) $632.03
ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL $89.00
5B1473 GREEN BUILDING STATE STANDARDS FEE $8.00
STRONG MOTION-COMMERCIAL -
$49.84
Total Fees: $1,681.77 Total Payments To Date: $1,681.77 Balance Due: $0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are her FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired. -
Building Division
1635 Faraday Avenue, Carlsbad CA 92008-7314 1760-602-2700 1760-602-8560 f 1.www.carlsbadca.gov Oage 1 of 1
(City o f
Carlsbad
COMMERCIAL
BUILDING PERMIT
APPLICATION
B-2
Plan Check CC2OIq051(
Est. Value ¶I1,cfl.(J
PC Deposit
Date
Job Address 2110 Thi-r t214 Or Suite: APN:
Tenant Name: CT/Project #: Lot #:________
Occupancy: ''— Construction Type: V? Fire sprinklers: 4M no Air Conditioning:/ no
BRIEF lDESCRIPTION I
U Addition/New: New SF and Use, ___New SF and Use,
Deck SF, Patio Cover SF (not including flatwork)
U Tenant Improvement: SF, Existing Use Proposed Use
SF, Existing Use Proposed Use
U. Pool/Spa: SF Additional Gas or Electrical Features?
U Solar: KW, _Modules, Mounted, Tilt: Yes / No, RMA: Yes / No, Panel Upgrade: Yes / No
Plumbing/Mechanical/Electrical Only: /D?' 42 gl fr' L/P7
Other:
II&1jIk'Y1 Va
- TiL1
PROPERTY OWNER
ame: now
Address: LfP. ho?S /2O/ -
City: State: t54' Zip: I 2-ö1'
Phone: (QJ -4. -
Email: c4. ra(? e4p,liri.
COJCTOR BUSINESS çrVt-f €,jv(jiITth)&
Name: S-oir TIUk' "(2 19 4
Address: P•ø 8 u Y
City:&Y _5ei State: CI Zip: 1100
Phone: -74'/- obbB
Email: )1i ,v_PS wrrc ,,nua7 ,oii. 6uà10
State License: __cLJ Bus. License:______________ BLO6, - s'Z
DESIGN PROFESSIONAL
Name:
Address: 9 O4'5' ffl1
City: f4/.J j7L' State: _Zip: Q21/7/
Phone: t't? -:217—
Email: cIQfl ,Q #9L4t
Architect State License:
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law
(Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he/she is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)).
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov
B-2 Page 1 of 2 . Rev. 06/18
0 (OPTION A ): WORKERS'COMPENSATION DECLARATION:
I hearby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the
work which this permit is issued.
jhave and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
My workers' compensation insurance carrier and policy number are: Insurance Company Name: icQi T PP I( I V's t.flL I -e t
Policy No. 660016,4'6I',i Expiration Date: u/i 9j2L7cb
O Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come
subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful, and shall subject an employer to
criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code,
interest and attorney's fees.
CONTRACTOR SIGNATURE: AAGENT DATE: t,'/o ISA.
OPTION B ): OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor's License Law for the following reason:
O I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work
himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
O I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
O I am exempt under Section ___Business and Professions Code for this reason:
I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 Yes ONO
I (have / have not) signed an application for a building permit for the proposed work.
I have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number):
I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address/ phone /
contractors' license number):
S. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work):
OWNER SIGNATURE: DAGENT DATE:
0 CONSTRUCTION LENDING AGENCY, IF ANY:
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (I) Civil Code).
Lender's Name: Lender's Address:
ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY:
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration to rm or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 Yes ONO
Is the applicant or future building occupant required to obtain a permit from the air pollution control dirict or air quality management district? 0 Yes Ø.No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? DYes Wo
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
APPLICANT CERTIFICATION:
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction.
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP
HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF
THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over 5'O' deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the Buildi OfflciaIunder the provisions of this Code shall expire by limitation and become null and void if the building or work authorized
by such permit is not commenced within 180 ays from e date of such permit or if the building or work authorized by such permit is suspended or abandoned at anytime
after the work is commenced for a period of 1 0 d (S on 106.4.4 Uniform Building Code).
APPLICANT SIGNATURE: "!X' DATE: )(
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: BuiIdingcCarISbadca.gov
B-2 Page 2 of 2 Rev. 06/18
Permit Type: BLDG-Commercial Application Date: 12/03/2019 Owner: ORANGE LAND HOLDINGS LLC
Work Class: Tenant Improvement Issue Date: 02/05/2020 Subdivision: TOWN OF CARLSBAD AMENDED
Status: Closed - Finaled Expiration Date: 02/08/2021 Address: 2910 JEFFERSON ST
IVR Number: 23442 CARLSBAD, CA 92008-2357
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date ' Start Date Status
Checklist Item COMMENTS Passed
BLDG-Building Deficiency See card for pick up. No
BLDG-Electrical Final No
L°02 0512612020 BLDG-Finalnspechon 128434-2020 I. Michael Coffins Responhcompte j
Checklist Item COMMENTS Passed
BLDG-Building Deficiency See card for pick up. No
BLDG-Building Deficiency Cancelled per contractor No
BLDG-Electrical Final No
05/27/2020 05/2712020 BLDG-Final Inspection 128578-2020 Passed .Michael Collins . CompIete
Checklist Item COMMENTS Passed'
BLDG-Building Deficiency Cancelled per contractor No
BLDG-Building Deficiency See card for pick up. • No
BLDG-Building Deficiency 5/27/20. Platform lift keyed entry bypassed ) Yes
to accommodate non attendant use.
BLDG-Electrical Final No
NOTES Created By TEXT Created Date
Michael Collins Platform lift keyed entry/use bypassed to 05/27/2020
accommodate use of lift without an attendant
present. *
Wednesday, May 27, 2020 - Page 2 of 2
Building Permit Inspection History Finaled
Gity of
Carlsbad
Permit Type: BLDG-Commercial Application bate: 12/03/2019 Owner: ORANGE LAND HOLDINGS LLC
Work Class: Tenant Improvement Issue Date: 02/05/2020 Subdivision: TOWN OF CARLSBAD AMENDED
Status: Closed - Finaled Expiration Date: 02/08/2021 Address: 2910 JEFFERSON ST
CARLSBAD, CA 92008-2357 IVR Number: 23442
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
0311212020 03112/2020 BLDG-84 Rough 122131-2020 Partial Pass Michael Collins Reinspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Prelim frame walk at exterior walls Yes
03/16/2020 03116/2020 BLDG-14 122300-2020 Partial Pass Michael Collins Reinspection Incomplete
FramelSteellBoltinglWe
Iding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Partial at west side architectural frame Yes
only. See card
03120/2020 03120/2020 BLDG-14 122823.2020 Passed Tony Alvarado - Complete
Frame/Steel/Bolting/We
Iding(Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Partial at west side architectural frame Yes
only. See card
• BLDG-Building Deficiency March 20, 2020: Yes
1. Architectural furred-out, architectural
features, rough framing and electrical
scope of work-approved per plan, details,
and revised letter from structural engineer
(filed in city records)-approved.
03/2412020 03/24/2020 BLDG-18 Exterior 123189-2020 Partial Pass Michael Collins Reinspection Incomplete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Partial, prelim exterior wrap Yes
04/30/2020 04/30/2020 BLDG-97 Disabled 126259-2020 Partial Pass Michael Collins Reinspection Incomplete
Accessibility
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Walkway at side of building • Yes
05/05/2020 05/05/2020 BLDG-97 Disabled 126731-2020 Partial Pass Michael Collins Reinspection Incomplete
Accessibility
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Walkway at side of building Yes
05/19I2020 05119/2020 BLDG-Final Inspection 127884-2020 Failed - Michael Collins Reinspection Incomplete
Wednesday, May 27, 2020 Page 1 of 2
420 Compose Road • OceanIdøCAI 92054 u'SI OFflco(?60)fl4.FaX(760453-2144
NARBETH STRUCTURAL INSPECTION
l08t40. ®[
Authorized
Speclaf Inspector
0 REINFORCED CONCRETE 0
0 PRE.SThESSED CONCRETE 0
0 0
SWUC1 STEEL ASSEMBLY Q SPFY.APPtjJiROOING
REINFORCED GYPSUM 1pR1ER_F6'i',7
DEEP FOUNDATION
JO SOS • 10 3ff7424J 77 (fL21L12 ®
BUILDING PERMIT NUMBER j PLAN FILE NUMBER
OWN OR PROJECT NAME
t4i'0 qit.4
AR CT o
Sm. MAI'L(TYPE. GRADE. ETC.) • DESIGN SOURCE OFMFGR. ENG!
DESCRIBE MAfl. (MDC DESIGN. RE-BAR GRADE &MFGR. WELD-ROD, ErG,) ® SEN % 0
I / /ff.W2o7c!. /q21
CONTR. DOING REPORTED WORK
.AB. RECEIVING & TEStiNG GOPIISTR. W,IPL SAMPLES
ITECO
DAYS WORK
ARRIVAL TIME DERARiURE rMj
rAILED - LOCAflON OF WORK INSPECTED, TEST SAMPI.ES 1IN. WORK REJECTED, JOB PROBLEMS IIROGREBS REMARKS, ETC. REPO1OF ABOtIT.AMOa'4tS OF MAtERIAl. PLACED OR WORK pRgORMED. NU$SER. TYPES WENT. NOS0F
INSPECTEDTESTSAMPl.ESTAICEN. SIRUCT. CONNECTIONS (WELDS MADE, Hi'. BOUSTOROUED) C*(EC1. ETC.
6)
J4F4 01 Irf fsi ArT
L/ 3"Mw. 1'tf /tjre &ArAga 91.4
(
Ø5/e -,-u- kr .
__ fZ Jff4&-
J7
/-
___
RECORD COPY
THIS REPORT DOES NOT RELIEVE THE CONTRACTOR OF HIS RESPONSIBILIVI'TO BUILD
PER THE PLANS, SPECIFICATIONS AND ALL APPUCABLE CODES.
10 THE BEST OF MYICNOWLEDGE. WORK INSPECTED WAS IN ACCORDANCE INSPEQTOR (rIro,I 4I.(JWI 1&4i4i!T14 6)
WITH THE SOI. IWVESflGAflON RECOMMENOATION&•NE APPROVED PLANS,
SPECtFICAT%ONS. AND APPLICABLE SECTIONS OF THE U.S.C. BUILDING CODE, SIGNATURE_______________________________________
UNLESS OTHERWISE NOTED. DATESIGNEDJ 7/ IJt7cERTtFicATE Na51J4Z
WHITE. NSI CANARY- Ccritmctor PINK - Building official
HTK
STRUCTURAL ENGINEERS, LLP
14288 Danielson Street • Suite #200 • Poway. CA 92064-8819
(858) 679-8989 • WIW!. HTKSE.COM • Fax (858) 679-8959 MEMORANDUM
DATE: March 18, 2020
TO: Dan Mullen
PROJECT: Jefferson ( j -ppgS: 2-110 C4?$D,4
PROJEcT No.: 19-421 (ci-pc1-14a: C62-0I' -ass-A,)
The studs may be butt jointed with sister studs and stitch nailed with 16d @ 16"
minimum.
Stitch nailing called out on details. V
None of the new and/or expanded openings require design changes in the existing
lateral system or shearwalls except as indicated on the approved permitted plans.
If you have any further questions, please contact me at any time.
From: HTK
Copies to: File RECORD COPY Page 1
EsGil
A SAFEbuittCompany
DATE: JAN. 15, 2020
JURISDICTION: CARLSBAD
PLAN CHECK #.: CBC2019-0558 SET: II
PROJECT ADDRESS: 2910 JEFFERSON STREET
APPLICANT
JURIS.
PROJECT NAME: ORANGE LAND HOLDINGS, LLC - FACADE REMODEL
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdictions building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
LII The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
LI The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant•
contact person.
The applicant's copy of the check list has been sent to:
EsGil staff did not advise the applicant that the plan check has been completed.
EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Don Glatthorn
Dil
tacted:
elephone Fax In Person
F-1 ¶S:
Telephone #: 619-920-6564
Email: dep.northcoast(qmail.com
By: ALl SADRE, S.E. Enclosures:
EsGil
1/08
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576
EsGil
A SAFEbuiIf Company
DATE: DEC. 13, 2019 0 APPLICANT
0 JURIS.
JURISDICTION: CARLSBAD
PLAN CHECK #.: CBC2019-0558 SET: I
PROJECT ADDRESS: 2910 JEFFERSON STREET
PROJECT NAME: ORANGE LAND HOLDINGS, LLC - FACADE REMODEL
El The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
El The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
El The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
El The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
El EsGil staff did not advise the applicant that the plan check has been completed.
EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Don Glatthorn Telephone #: 619-920-6564
Date contacted (by: ) Email: deq.northcoast1qmail.com
Mail Telephone Fax In Person
El REMARKS:
By: ALl SADRE, S.E. Enclosures:
EsGil
12/05
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576
CARLSBAD CBC20 19-0558
DEC. 139 2019
GENERAL PLAN CORRECTION LIST
JURISDICTION: CARLSBAD PLAN CHECK #.: CBC2019-0558
PROJECT ADDRESS: 2910 JEFFERSON STREET
SCOPE = FACADE REMODEL; CONSTRUCTION = V-B; STORIES =2+ BASEMENT;
SPRINKLERS = YES; HEIGHT = NO CHANGE; OCCUPANCY = B/S-2
DATE PLAN RECEIVED BY DATE REVIEW COMPLETED:
ESGIL: 12/05 DEC. 13, 2019
REVIEWED BY: ALl: SADRE, S.E.
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the International
Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical
Code and state laws regulating energy conservation, noise attenuation and disabled
access. This plan review is based on regulations enforced by the Building Department.
You may have other corrections based on laws and ordinances enforced by the
Planning Department, Engineering Department or other departments.
The following items listed need clarification, modification or change. All items must be
satisfied before the plans will be in conformance with the cited codes and regulations.
The approval of the plans does not permit the violation of any state, county or city law.
GENERAL
Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted in one
of two ways:
Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700.
The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire
Departments.
Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake
Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of
plans and calculations/reports directly to the City of Carlsbad Building Department for
routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City
Planning, Engineering and Fire Departments until review by EsGil is complete.
2. To facilitate rechecking, please identify, next to each item, the sheet of the
plans upon which each correction on this sheet has been made and return
this sheet with the revised plans.
CARLSBAD CBC2019-0558
DEC. 13, 2019
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this Ilist. If there are other changes, please briefly
describe them and where they are located on the plans. Have changes been
made not resulting from this list? 0 Yes U No
PLANS
Inked in changes are not permitted on the plans. i.e., please update the owner's
address on the cover sheet of the plans.
Please complete the blank bubbles on the plans. I.e., see elevations 2/A2-6; I &
2/A2-7; detail 15/AD-2; detail 19/AD-3; etc.
Please coordinate Sheets A2-5 & A2-6, as per Sheet Index, with the content of
the plans.
STRUCTURAL
Please show a plan view for the base on detail I 3/SDI. Indicate the base plate
dimension and clearances, as well as the weld size and type to the tube column
and Titen anchor embedment.
MISCELLANEOUS
The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to
perform the plan review for your project. If you have any questions regarding
these plan review items, please contact ALl SADRE, S.E. at EsGil. Thank you.
CARLSBAD CBC2019-0558
DEC. 13, 2019
[DO NOT PAY— THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: CARLSBAD PLAN CHECK #.: CBC2019-0558
PREPARED BY: ALl SADRE, S.E. DATE: DEC. 13, 2019
BUILDING ADDRESS: 2910 JEFFERSON STREET
BUILDING OCCUPANCY: B/S-2; V-B/SPR.
BUILDING
PORTION
AREA
(Sq. Ft.)
Valuation
Multçlier
Reg.
Mod.
VALUE ($)
FAADE
REMODEL
Air Conditioning
Fire Sprinklers
TOTAL VALUE 178,000
Jurisdiction Code ICB JBy Ordinance
11997 UBC Building Permit Fee LJ lAl t4:
11997 UBC Plan Check Fee Lml I Al st:
Type of Review: F Complete Review r Structural Only
r Repetitive Fee
I j Repeats
p.
r Other
r Hourly
EsGil Fee
p. I $586.921
Comments:
Sheet 1 of 1
SEISMIC FORCE: .
STRUCTURAL STEEL: A-36
LUMBER: DOUGLAS FIR-LARCH
JOISTS
BEAMS AND POSTS
STUDS
CONCRETE STRENGTH STRENGTH AT TWENTY EIGHT DAYS:
MASONRY: GRADE "N" CONCRETE BLOCK F' M =
MORTAR: TYPES 1,800 PSI
GROUT: 2000 PSI
REINFORCING STEEL: A-615 GRADE 40: #4 AND LESS (U.O.N.)
GRADE 60: #5 AND LARGER
PROJECT: '?5t0 IJQJ
#2
#2
STUD OR BETTER
REPORT BY: C4C_. di''S
I IHTI '..
STRUTL ENGINEERSLLP
001,
(a PSI 0 Cit. 12 't.S#C4.) PSI
STRUCTURAL CALCULATIONS
WIND FORCE: tt C) t"- REPORT NO.:._________________ SOIL PRESSURE:______________
DESIGN LOADS:
ROOF DEAD LOAD
SLOPING
ROOFING
PLYWOOD
JOISTS
INSUL & CLG.
MISC.
FLOOR DEAD LOAD
FLAT INT.
FLOORING
PLYWOOD
JOISTS
INSUL. & CLG.
MISC.
1.4 TOTAL=
FLOOR LIVE LOAD
INTERIOR
BALCONY
EXIT WALKWAY
WALL DEAD LOAD
INTERIOR 10 PSF
EXTERIOR 16 PSF
TOTAL =
ROOF LIVE LOAD
SLOPING = 2C7
FLAT=
40 PSF
60 PSF (U.O.N.)
100 PSF
These calculations are limited only to the items included herein, selected by the client and do not imply approval of any
other portion of the structure by this office. These calculations are not valid if altered in any way, or not accompanied by a
wet stamp and signature of the Engineer of Record.
San Diego - 14299 Danielson Strait Suite * 200. Pow.y, CA 92064. (958) 679-6999. Fax (858) 679-9959
c8c,lam 40
/\j 1HTK. S-rnucru AL ENGINEERS. LLP
www.htkse.com
SHEET:
PROJECT:
DESIGNEft
fIP at,2 W nLx L -
W 6mv
'QAst cAit Logic kJ tF2&) = 3Z!%(
L'4i) t3l l6ts 14( ei
e
ci:i'tI 1t'/0 L
kb c"o -
C° U.
HiTK
STRUCTURAL ENGINEERS. LLP
www.htkse.com
Q') QPeAJV'/i.1' Vs-) (A#%(j
tc'
Ø4t CA) ;/—
De34r C3EL 4p4%1
SHEET:
PROJECT:
DESIGNER:
I
MWFRS Wind Loads 'Job No:
ASCT 7-10 IDesIgnc
1 [tILTJc J___ Enclosed & Partially Enclosed Low Rise Buildings Ithe1
Basic Parameters
Risk Category II Table 15-1
Basic Wind Speed, V 120 mph Figure 26.5-IA
Wind Directionality Factor, Kd 0.85 Table 26.6-1
Exposure Category ASection 26.7
Topographic Factor, lC, 1.00 Section 26.8
Enclosure Classification Enclosed Section 26.10
Internal Pressure Coefficient, GC., +/-0.18 Table 26.11-1
Pressure Coefficients
Roof Slope 5/12 22.6 degrees
Wall External Pressure Coefficient, GC.A 0.538 Table 28.4-1, Surface 1
Roof External Pressure Coefficient, GC, -0.46 Table 28.4-1, Surface 2
Roof External Pressure Coeffident, GC,1 -0.467 Table 28.4-1, Surface 3
Wail External Pressure Coefficient, GCpf -0.414 Table 28.4-1. Surface 4
Sfructure Pressure Sumnia,v (Add Internal Pressure o.GC1.. or ehGç.. as Necessary)
Helghtz K, ______ Walls ____ Roofs Comp & aadding
Windward LTotai0.6 Windward LeewardlTotai*0.6 P0.6
15ff 0.85 22.4 psf 16.1 psf 17.6 psf -143 psf f4 -02 psf 1.21 16.2 psf
20ft 0.90 23.7 paf 17.0psf 187 pisf -15.2 psf i4 -0.3 psf 1.29 18.3 psf
25 ft 0.94 24.7 psf 17.8 psf -19.5 psf
022.6
-15.8 psf -14.7 p4 -03 psf 1.35 20.0 psf
30 ft 0.98 25.8 psf 18.5 psf -20.3 psf -16.5 psI -15.3 ps4 .0.3 psf 1.4 21.7 psf
40ft 1.04 27.4 psf 19.7 psf - 21.6 psf -17.5 psf -16.3 p4-0.3 psf 1.49 24.5 psf
SOft 1.09 28.7 psf 20.6 psf -22.6 psI -184 psf 9i4 -0.3 psI 1.56 26.9 psf
60ft 1.13 29.8 psI 21.4 psf -23.4 psf -19.0 psf -17.7 p4 .0.3 psf 1.62 28.9 psI
can ire ugnoree ntotau pressure is
Page 1 of 1
CTOT
Asbestos Bulk Sampling Report
Conducted at
2910 Jefferson Street
Carlsbad, CA 92008
Conducted For
Orange Land Holding, LLC
Attn: Don Gatthorn
Tel: 619-920-6564
Email: deg.northcoast@gmail.com
FEB 0 5 2020
cn-Y c:
LI u U - •
Survey Date
January 08, 2020
Report Date
January 13, 2020
ET&T Project No. 197621
Environmental Testing & Technology, Inc. (ET&T)
1,106 Second Street, Suite 102 A Encinitas, CA 92024
Tel: 760-804-9400 A www.ETandT.com A www.EMFRF.com
www.ETandT.com
Page 1 of 5
**boo I
*** )00*1001, NDOOR1ENVIRON
Dear Don,
This report summarizes the findings of our asbestos sampling conducted at the residence located at
2910 Jefferson Street, Carlsbad, CA 92008. Our survey was conducted on January 08, 2020, by Mr.
Andrew Jordan, Certified Asbestos Consultant with ET&T.
1. Scope of Work
The purpose of this limited survey was to collect bulk samples of suspect asbestos containing building
materials which may be disturbed during building improvements. The samples were sent to an
NlST/NVLAP accredited lab for analysis. The following procedures were conducted as part of the
assessment:
Limited visual inspection in readily accessible areas of concern.
Collection of suspect asbestos containing materials.
Written report and laboratory data interpretation.
2. Asbestos Bulk Sampling
The purpose of bulk sampling is to determine if a material contains asbestos. Asbestos "bulk" samples
were taken by "wetting" a suspect surface with a surfactant and collecting the material. These materials
are sent to an accredited laboratory for analysis by polarized light microscopy (PLM) by EPA method
600/R-93-116. Asbestos containing material is a material that contains greater than 1% asbestos.
1106 Second Street, Suite 102 • Encinitas, CA 92024 • Tel: (760) 804-9400• Fax: (760) 630-9303
ET&T Job # 197621 • 2910 Jefferson St., Carlsbad, CA 92008 • Survey Date: January 08, 2020
www.ETandT.com
Page 2 of 5
Asbestos Bulk Sampling Results
Table 1: Asbestos Bulk Sampling Results
Sample ID [ -
Location - Material
- - -
Results
01 Suite #101— Northwest Office Wall: Drywall/Joint Compound ND
- - -
02 [ Suite #101—Bathroom Wall: Drywall/Joint Compound
-
ND
03 -Suite #101 —Southwest Office Wall: Drywall/JointCompound - -
ND
04 Suite #101—Lobby Wall: Drywall/Joint Compound ND
-
05 Suite #101—Southeast Room Wall: Drywall/Joint Compound ND
06 Suite #101 - Ceiling Tile (Beige/Course) IND -
07 Suite #101— Ceiling Tile (White/Smooth) ND
08
-
Suite #101 - Ceiling Tile in Bathroom
-
ND
09 Suite #101— Bathroom: Floor Tile (Top Layer)
-
ND
-F 10 Suite #101 - Bathroom: Floor Tile (Bottom Layer) ND
11 Suite #101 - Lobby: Carpet Mastic
- -
ND
12 F_ Suite #101 - Lobby: Desk Mastic
- -
ND
-
13 Suite #103 - Lobby Wall: Drywall/Joint Compound
- - -
ND
-
14 Suite #103 - Center Room Wall: Drywall/Joint Compound
-
ND
15 Suite #103—Corner Room Wall: Drywall/Joint Compound
-
ND
-
16 Suite #103 - Ceiling Tile (Beige/Course)
- - -
ND
-
17 F - Suite #103 - Ceiling Tile (Beige/Smooth)
- - -
ND
18 Suite #103 - Bathroom: Vinyl Flooring &_Mastic ND
19
T_
- - -
Suite #103 - Carpet Mastic
- -
ND
20 Suite #100—Lobby Wall: Drywall/Joint Compound ND
21 F Suite #100—Exam Room #6 Wall: Drywall/Joint Compound ND
22 T Suite #100—Exam Room #3 Wall: Drywall/Joint Compound ND
1106 Second Street, Suite 102 • Encinitas, CA 92024 • Tel: (760) 804-9400• Fax: (760) 630-9303
ET&T Job # 197621 • 2910 Jefferson St., Carlsbad, CA 92008 • Survey Date: January 08, 2020
www.ETandT.com
Page 3 of 5
ET&T0.94. _-, 1~_ ii'it'I'i 1EWIRONMENTALI
23 Suite #100—Bathroom Wall: Drywall/Joint Compound
- - -
ND
24 Suite #100 - Exam Room #2 Wall: Drywall/Joint Compound ND
-
25 Suite #100 - Break Room: Linoleum ND
26 Suite #100 - Lobby: Ceiling Tile
- - -
ND
-
27 Floor #1—CommonHallway: Ceiling Tile
- -- -
ND
28 F Floor #1—Common Hallway: Carpet Mastic ND
29 Suite #201 - Entry Wall: Drywall/Joint Compound ND
-
30 j Suite #201 -Southwest Room Wall: Drywall/Joint Compound
- -
ND
-
31 Suite #201— South Room Wall: Drywall/Joint Compound F- ND
32 Suite #201: Ceiling Tile ND
33 Suite #203 - Front Entry Wall: Drywall/Joint Compound ND
34 Suite #203 - South Room Wall: Drywall/Joint Compound ND
35 Suite #203 - North Room Wall: Drywall/Joint Compound ND
36 Suite #203: Ceiling Tile
-
ND
37 Suite #203: Carpet Mastic ND
38 Exterior: Building Paper behind Wood Siding (West)
-
ND
39 Exterior: Building Paper behind Wood Siding (North) ND
F
40 Exterior: Building Paper behind Wood Siding (South)
- -
ND
41 Exterior: Building Paper behind Wood Siding (East)
-- -
ND
42 Exterior: Siding Caulking ND
43 Exterior: Siding Caulking F_ ND
44 I Exterior: Siding Caulking -
ND
ND = No Asbestos Fibers Detected
1106 Second Street, Suite 102• Encinitas, CA 92024 • Tel: (760) 804-9400• Fax: (760) 630-9303
ET&T Job # 197621 • 2910 Jefferson St., Carlsbad, CA 92008 • Survey Date: January 08, 2020
www.ETandT.com
Page 4 of 5
INDOOR ENVVIRONMERNTAL
4. Summary
There were forty-four (44) bulk samples collected from suspect asbestos containing building materials
during the survey. There were no asbestos fibers detected in the drywall/joint compound samples
collected from inside the master bathroom. Asbestos containing material is a material that contains
greater than 1% asbestos. Please see Table 1 and the attached laboratory report for more information.
S. Important Notice
A diligent inspection of normally visible and accessible areas was made in accordance with the scope of
work. However, due to the inherent limitations of the physical inspection process, Environmental
Testing & Technology Inc. cannot report, or accept responsibility for, materials or conditions which may
exist in areas that were inaccessible at the time of its inspection. This survey cannot guarantee or
warrantee the absence of asbestos or other environmental hazards in areas not accessible for inspection
and testing.
This inspection is not intended to reflect the structural integrity, or value of the property, nor do we
make any representation as to the advisability of purchase or the suitability for use. We do not assume
responsibility for choices or decisions made regarding the purchase or rental of properties, mitigation or
potential legal action, based on our measurements. The inspection is not intended to be technically
exhaustive, and is not to be used as a guarantee or warranty, expressed or implied, regarding the
adequacy, performance, or condition of the inspected structure.
If you have any further questions regarding the survey and report feel free to contact us at
760-804-9400.
Sincerely,
DRLWM.IORDAI
Andrew M. Jordan, BA
Certified Asbestos Consultant (CAC) - No. 11-4739 oicwnt Ii
Certified Microbial Consultant (CIVIC) - ACAC No. 1305046
Certified Lead Inspector/Assessor - CDPH No. 26593
Certified Applied Microbial Remediation Technician (AMRT) - IICRC No. 126470
Certified Water Damage Restoration Technician (WRT) - IICRC No. 126470
ATTACHMENTS
. Asbestos Bulk Sampling Report - 13 Pages
1106 Second Street, Suite 102• Encinitas, CA 92024 • Tel: (760) 804-9400• Fax: (760) 630-9303
ET&T Job # 197621 • 2910 Jefferson St., Carlsbad, CA 92008 • Survey Date: January 08, 2020
www.ETandT.com
Page 5 of 5
eurofins
EMLab P&K
Report for:
Mr. Andrew Jordan
Environmental Testing & Technology
1106 Second St.
Suite #102
Encinitas, CA 92024
Regarding: Project: 197621; Asbestos
EML ID: 2329884
L }
FEB 05 2020
Approved by: Dates of Analysis:
Asbestos PLM: 01-10-2020 and 01 -13-2020
Approved Signatory
Danny Li
Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM-AS-S-1 267)
NVLAP Lab Code 200757-0
All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The
results relate only to the samples as received. The results include an inherent uncertainty of measurement associated with
estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos
concentration can be provided when requested.
Eurofins EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or
recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result
of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for
the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential
damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been
advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the
Test Results exceed the amount paid to the Company by the client therefor.
EMLab P&K, LLC EMLab ID: 2329884, Page 1 of 13
Client: Environmental Testing & Technology
CIO: Mr. Andrew Jordan
Re: 197621; Asbestos
ASBESTOS PLM REPORT
Eurofins EMLab P&K
17461 Derian Ave, Suite 100, Irvine, CA 92614
(866) 888-6653 Fax (623) 780-7695 www.em1ab.com
Date of Sampling: 01-08-2020
Date of Receipt: 01-08-2020
Date of Report: 01-13-2020
Total Samples Submitted: 44
Total Samples Analyzed: 44
Total Samples with Layer Asbestos Content> 1%: 0
Location: 01, Ste #101 NW Office Wall DW/JC Lab 1D-Version: 11088905-I
Sample Layers Asbestos Content
Off-White Joint Compound with Paint ND
White Joint Compound ND
Cream Tape ND
White Joint Compound ND
White Drywall with Brown Paper ND
Composite Non-Asbestos Content: 10% Cellulose
Sample Composite Homogeneity: Poor
Location: 02, Ste #101 Bathroom Wall DW/JC Lab ID-VersionS: 11088906-I
Sample Layers Asbestos Content
White Joint Compound with Paint ND
Cream Tape ND
White Joint Compound ND
White Drywall with Brown Paper ND
Composite Non-Asbestos Content: 10% Cellulose
Sample Composite Homogeneity: Poor
Location: 03, Ste #101 SW Office Wall DW/JC Lab 1D-Version: 11088907-1
Sample Layers Asbestos Content
White Joint Compound with Paint ND
Cream Tape ND
White Joint Compound ND
White Drywall with Brown Paper ND
Composite Non-Asbestos Content: 10% Cellulose
Sample Composite Homogeneity: Poor
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any, agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneóus samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
A "Version" indicated by -"x" after the Lab IM with a value greater than I indicates a sample with amended data. The revision number is
reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2329884, Page 2 of 13
Client: Environmental Testing & Technology
C/O: Mr. Andrew Jordan
Re: 197621; Asbestos
ASBESTOS PLM REPORT
Location: 04, Ste #101 Lobby Wall DW/JC
Eurofins EMLab P&K
17461 Derian Ave, Suite 100, Irvine, CA 92614
(866) 888-6653 Fax (623) 780-7695 www.em1ab.com
Date of Sampling: 01-08-2020
Date of Receipt: 01-08-2020
Date of Report: 01-13-2020
Lab ID-VersionS: 11088908-1
Sample Layers Asbestos Content
White Joint Compound with Paint ND
Cream Tape ND
White Joint Compound ND
White Drywall with Brown Paper ND
Composite Non-Asbestos Content: 10% Cellulose
Sample Composite Homogeneity: Poor
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
reflected by the value of 'W'.
EMLab P&K, LLC EMLab ID: 2329884, Page 3 of 13
Client: Environmental Testing & Technology
CIO: Mr. Andrew Jordan
Re: 197621; Asbestos
ASBESTOS PLM REPORT
Location: 05, Ste #101 SE Room Wall DW/JC
Eurofins EMLab P&K
17461 Derian Ave, Suite 100, Irvine, CA 92614
(866) 888-6653 Fax (623) 780-7695 www.em1ab.com
Date of Sampling: 01-08-2020
Date of Receipt: 01-08-2020
Date of Report: 01-13-2020
Lab ID-VersionS: 11088909-I
Sample Layers Asbestos Content
White Joint Compound with Paint ND
Cream Tape ND
White Joint Compound ND
White Drywall with Brown Paper ND
Composite Non-Asbestos Content: 10% Cellulose
Sample Composite Homogeneity: Poor
Location: 06, Ste #101 Ceiling Tile (Beige/Course) Lab 1D-Version: 11088910-1
Sample Layers Asbestos Content
Light Brown Ceiling Tile with White Surface ND
Composite Non-Asbestos Content: 35% Cellulose
20% Glass Fibers
Sample Composite Homogeneity: Moderate
Location: 07, Ste #101 Ceiling Tile (White/Smooth) Lab ID-VersionS: 11088911 -1
Sample Layers Asbestos Content
Light Brown Ceiling Tile with White Surface ND
Composite Non-Asbestos Content: 35% Cellulose
20% Glass Fibers
Sample Composite Homogeneity: Moderate
Location: 08, Ste #101 Ceiling Tile (Bathroom) Lab ID-VersionS: II088912-1
Sample Layers Asbestos Content
Blue Drywall with Brown Paper ND
Composite Non-Asbestos Content: 10% Cellulose
Sample Composite Homogeneity: Moderate
Comments: Ceiling Tile not detected.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
A "Version" indicated by -"x" after the Lab ID# with a value greater than I indicates a sample with amended data. The revision number is
reflected by the value of "x". -
EMLab P&K, LLC EMLab ID: 2329884, Page 4 of 13
Client: Environmental Testing & Technology
C/O: Mr. Andrew Jordan
Re: 197621; Asbestos
Eurofins EMLab P&K
17461 Derian Ave, Suite 100, Irvine, CA 92614
(866) 888-6653 Fax (623) 780-7695 www.emlab.com
Date of Sampling: 01-08-2020
Date of Receipt: 01-08-2020
Date of Report: 01-13-2020
ASBESTOS PLM REPORT
Location: 09, Ste #101 Bathroom Floor Tile (Top Layer) Lab 1D-Version: 11088913-I
Sample Layers Asbestos Content
Off-White Floor Tile ND
Sample Composite Homogeneity: Moderate
Location: 10, Ste #101 Bathroom Floor Tile (Bottom Layer) Lab ID-VersionS: 11088914-I
Sample Layers Asbestos Content
Off-White Floor Tile ND
Transparent Glue ND
White Leveling Compound ND
Sample Composite Homogeneity: Moderate
Location: 11, Ste #101 Lobby Carpet Mastic Lab ID-Version*: 11088915-1
Sample Layers Asbestos Content
Yellow Mastic ND
Sample Composite Homogeneity: Moderate
Location: 12, Ste #101 Lobby Desk Mastic Lab ID-VersionS: 11088916-I
Sample Layers Asbestos Content
Yellow Mastic ND
Sample Composite Homogeneity: Moderate
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
A "Version" indicated by -"x" after the Lab ID# with a value greater than I indicates a sample with amended data. The revision number is
reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2329884, Page 5 of 13
Client: Environmental Testing & Technology
CIO: Mr. Andrew Jordan
Re: 197621; Asbestos
ASBESTOS PLM REPORT
Location: 13, Ste #103 Lobby Wall DW/JC
Eurofins EMLab P&K
17461 Derian Ave, Suite 100, Irvine, CA 92614
(866) 888-6653 Fax (623) 780-7695 www.emlab.com
Date of Sampling: 01-08-2020
Date of Receipt: 01-08-2020
Date of Report: 01-13-2020
Lab 1D-Version: 11088917-I
Sample Layers Asbestos Content
White Joint Compound with Paint ND
Cream Tape ND
White Joint Compound ND
White Drywall with Brown Paper ND
Composite Non-Asbestos Content: 10% Cellulose
Sample Composite Homogeneity: Moderate
Location: 14, Ste #103 Center Room Wall DW/JC Lab ID-VersionS: 11088918-1
Sample Layers Asbestos Content
White Joint Compound with Paint ND
Cream Tape ND
White Joint Compound ND
White Drywall, with Brown Paper ND
Composite Non-Asbestos Content: 10% Cellulose
Sample Composite Homogeneity: Moderate
Location: 15, Ste #103 Corner Room Wall DW/JC Lab ID-Versiot4: 11088919-I
Sample Layers Asbestos Content
White Joint Compound with Paint ND
Cream Tape ND
White Joint Compound ND
White Drywall with Brown Paper ND
Composite Non-Asbestos Content: 10% Cellulose
Sample Composite Homogeneity: Moderate
Location: 16, Ste #103 Ceiling Tile (Beige/Course) Lab 1D-Version: 11088920-I
Sample Layers Asbestos Content
Light Brown Ceiling Tile with White Surface ND
Composite Non-Asbestos Content: 35% Cellulose
20% Glass Fibers
Sample Composite Homogeneity: Moderate
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
A "Version" indicated by -"x" after the Lab ID# with a value greater than I indicates a sample with amended data. The revision number is
reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2329884, Page 6 of 13
Client: Environmental Testing & Technology
C/O: Mr. Andrew Jordan
Re: 197621; Asbestos
ASBESTOS PLM REPORT
Location: 17, Ste #103 Ceiling Tile (Beige/Smooth)
Eurofins EMLab P&K
17461 Derian Ave, Suite 100, Irvine, CA 92614
(866) 888-6653 Fax (623) 780-7695 www.emlab.com
Date of Sampling: 01-08-2020
Date of Receipt: 01-08-2020
Date of Report: 01-13-2020
Lab ID-VersionS: 11088921-I
Sample Layers Asbestos Content
Light Brown Ceiling Tile with White Surface ND
Composite Non-Asbestos Content: 35% Cellulose
20% Glass Fibers
Sample Composite Homogeneity: Moderate
Location: 18, Ste #103 Bathroom Vinyl Flooring And Mastic Lab ID-VersionS: 11088922-I
Sample Layers Asbestos Content
Gray Sheet Flooring with Fibrous Backing ND
Yellow Mastic ND
Off-White Leveling Compound ND
Composite Non-Asbestos Content: 25% Cellulose
Sample Composite Homogeneity: I Moderate
Location: 19, Ste #103 Carpet Mastic Lab ID-Version: 11088923-1
Sample Layers Asbestos Content
Yellow Mastic ND
Off-White Leveling Compound ND
Sample Composite Homogeneity: Moderate
Location: 20, Ste #100 Lobby Wall DW/JC Lab 1D-Version: 11088924-I
Sample Layers Asbestos Content
White Joint Compound with Paint ND
Cream Tape ND
White Joint Compound ND
White Drywall with Brown Paper ND
Composite Non-Asbestos Content: 10% Cellulose
Sample Composite Homogeneity: Moderate
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2329884, Page 7 of 13
Client: Environmental Testing & Technology
C/O: Mr. Andrew Jordan
Re: 197621; Asbestos
ASBESTOS PLM REPORT
Location: 21, Ste #100 Exam #6 Wall DW/JC
Eurofins EMLab P&K
17461 Derian Ave, Suite 100, Irvine, CA 92614
(866) 888-6653 Fax (623) 780-7695 www.em1ab.com
Date of Sampling: 01-08-2020
Date of Receipt: 01-08-2020
Date of Report: 01-13-2020
Lab 1D-Version: 11088925-I
Sample Layers Asbestos Content
White Joint Compound with Paint ND
Cream Tape ND
White Joint Compound ND
White Drywall with Brown Paper ND
Composite Non-Asbestos Content: 10% Cellulose
Sample Composite Homogeneity: Moderate
Location: 22, Ste #100 Exam #3 Wall DW/JC Lab ID-Version*: 11088926-1
Sample Layers Asbestos Content
White Joint Compound with Paint ND
Cream Tape ND
White Joint Compound ND
White Drywall with Brown Paper ND
Composite Non-Asbestos Content: 10% Cellulose
Sample Composite Homogeneity: Moderate
Location: 23, Ste #100 Bathroom Wall DW/JC Lab 1D-Version: 11088927-1
Sample Layers Asbestos Content
White Joint Compound with Paint ND
Cream Tape ND
White Joint Compound ND
White Drywall with Brown Paper ND
Composite Non-Asbestos Content: 10% Cellulose
Sample Composite Homogeneity: Moderate
Location: 24, Ste #100 Exam #2 Wall DW/JC Lab ID-VersionS: 11088928-1
Sample Layers Asbestos Content
White Joint Compound with Paint ND
Cream Tape ND
White Joint Compound ND
White Drywall with Brown Paper ND
Composite Non-Asbestos Content: 10% Cellulose
Sample Composite Homogeneity: Moderate
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
A "Version" indicated by -"x" after the Lab ID# with a value greater than I indicates a sample with amended data. The revision number is
reflected by the value of N.I.
EMLab P&K, LLC EMLab ID: 2329884, Page 8 of 13
Client: Environmental Testing & Technology
C/O: Mr. Andrew Jordan
Re: 197621; Asbestos
ASBESTOS PLM REPORT
Location: 25, Ste #100 Break Room Linoleum
Eurofins EMLab P&K
17461 Derian Ave, Suite 100, Irvine, CA 92614
(866) 888-6653 Fax (623) 780-7695 www.emlab.com
Date of Sampling: 01-08-2020
Date of Receipt: 01-08-2020
Date of Report: 01-13-2020
Lab ID-VersionS: 11088929-1
Sample Layers Asbestos Content
Multicolored Linoleum with Fibrous Backing ND
Yellow Mastic ND
Composite Non-Asbestos Content: 25% Cellulose
Sample Composite Homogeneity: Moderate
Location: 26, Ste #100 Lobby Ceiling Tile Lab ID-VersionS: 11088930-I
Sample Layers Asbestos Content
Light Brown Ceiling Tile with White Surface ND
Composite Non-Asbestos Content: 35% Cellulose
20% Glass Fibers
Sample Composite Homogeneity: Moderate
Location: 27, Floor #1 Common Hallway Ceiling Tile Lab ID-VersionS: 11088931-I
Sample Layers Asbestos Content
Silver Foil ND
Light Brown Ceiling Tile with White Surface ND
Composite Non-Asbestos Content: 35% Cellulose
20% Glass Fibers
Sample Composite Homogeneity: I Moderate
Location: 28, Floor #1 Common Hallway Carpet Mastic Lab ID-VersionS: 11088932-I
Sample Layers Asbestos Content
Yellow Mastic ND
Sample Composite Homogeneity: Moderate
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
A "Version' indicated by -"x' after the Lab JD# with a value greater than 1 indicates a sample with amended data. The revision number is
reflected by the value of 'x".
EMLab P&K, LLC EMLab ID: 2329884, Page 9 of 13
Client: Environmental Testing & Technology
C/O: Mr. Andrew Jordan
Re: 197621; Asbestos
ASBESTOS PLM REPORT
Location: 29, Ste #201 Entry Wall DW/JC
Eurofins EMLab P&K
17461 Derian Ave, Suite 100, Irvine, CA 92614
(866) 888-6653 Fax (623) 780-7695 www.emlab.com
Date of Sampling: 01-08-2020
Date of Receipt: 01-08-2020
Date of Report: 01-13-2020
Lab 1D-Version: 11088933-1
Sample Layers Asbestos Content
White Joint Compound with Paint ND
Cream Tape ND
White Joint Compound ND
White Drywall with Brown Paper ND
Composite Non-Asbestos Content: 10% Cellulose
Sample Composite Homogeneity: Moderate
Location: 30, Ste #201 SW Room Wall DW/JC Lab 1D-Version: 11088934-1
Sample Layers Asbestos Content
White Joint Compound with Paint ND
Cream Tape ND
White Joint Compound ND
White Drywall with Brown Paper ND
Composite Non-Asbestos Content: 10% Cellulose
Sample Composite Homogeneity: Moderate
Location: 31, Ste #201 South Room Wall DW/JC Lab ID-VersionS: 11088935-1
Sample Layers Asbestos Content
White Joint Compound with Paint ND
White Drywall with Brown Paper ND
Composite Non-Asbestos Content: 10% Cellulose
Sample Composite Homogeneity: Moderate
Location: 32, Ste #201 Ceiling Tile Lab ID-VersionS: 11088936-1
Sample Layers Asbestos Content
Light Brown Ceiling Tile with White Surface ND
Composite Non-Asbestos Content: 35% Cellulose
20% Glass Fibers
Sample Composite Homogeneity: Moderate
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2329884, Page 10 of 13
Client: Environmental Testing & Technology
C/O: Mr. Andrew Jordan
Re: 197621; Asbestos
ASBESTOS PLM REPORT
Location: 33, Ste #203 Front Entry Wall DW/JC
Eurofins EMLab P&K
17461 Derian Ave, Suite 100, Irvine, CA 92614
(866) 888-6653 Fax (623) 780-7695 www.emlab.com
Date of Sampling: 01-08-2020
Date of Receipt: 01-08-2020
Date of Report: 01-13-2020
Lab ID-VersionS: 11088937-I
Sample Layers Asbestos Content
White Joint Compound with Paint ND
White Joint Compound with Paint ND
Cream Tape ND
White Joint Compound ND
White Drywall with Brown Paper ND
Composite Non-Asbestos Content: 10% Cellulose
Sample Composite Homogeneity: Moderate
Location: 34, Ste #203 South Room Wall DW/JC Lab ID-VersionS: 11088938-I
Sample Layers Asbestos Content
White Joint Compound with Paint ND
Cream Tape ND
White Joint Compound ND
White Drywall with Brown Paper ND
Composite Non-Asbestos Content: 10% Cellulose
Sample Composite Homogeneity: Moderate
Location: 35, Ste #203 North Room Wall DW/JC Lab ID-Version: 11088939-I
Sample Layers Asbestos Content
White Joint Compound with Paint ND
White Joint Compound with Paint ND
Cream Tape ND
White Joint Compound ND
White Drywall with Brown Paper ND
Composite Non-Asbestos Content: 10% Cellulose
Sample Composite Homogeneity: Moderate
Location: 36, Ste #203 Ceiling Tile Lab ID-Versioi4: 11088940-I
Sample Layers Asbestos Content
Light Brown Ceiling Tile with White Surface ND
Composite Non-Asbestos Content: 35% Cellulose
20% Glass Fibers
Sample Composite Homogeneity: Moderate
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large
amounts of interference material and it is recommended that-the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
reflected by the value of 'Y'.
EMLab P&K, LLC EMLab ID: 2329884, Page 11 of 13
Client: Environmental Testing & Technology
C/O: Mr. Andrew Jordan
Re: 197621; Asbestos
Eurofins EMLab P&K
17461 Derian Ave, Suite 100, Irvine, CA 92614
(866) 888-6653 Fax (623) 780-7695 www.em1ab.com
Date of Sampling: 01-08-2020
Date of Receipt: 01-08-2020
Date of Report: 01-13-2020
ASBESTOS PLM REPORT
Location: 37, Ste #203 Carpet Mastic Lab ID-Version: 11088941-I
Sample Layers Asbestos Content
Yellow Mastic ND
Sample Composite Homogeneity: Moderate
Location: 38, Exterior Building Paper Behind Wood Siding (West) Lab ID-VersionS: 11088942-I
Sample Layers Asbestos Content
Brown Paper ND
Composite Non-Asbestos Content: 45% Cellulose
Sample Composite Homogeneity: Moderate
Location: 39, Exterior Building Paper Behind Wood Siding (North) Lab ID-VersionS: 11088943-I
Sample Layers Asbestos Content
Brown Paper ND
Composite Non-Asbestos Content: 45% Cellulose
Sample Composite Homogeneity: Moderate
Location: 40, Exterior Building Paper Behind Wood Siding (South) Lab ID-VersionS: 11088944-1
Sample Layers Asbestos Content
Brown Paper ND
Composite Non-Asbestos Content: 45% Cellulose
Sample Composite Homogeneity: Moderate
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2329884, Page 12 of 13
Client: Environmental Testing & Technology
C/O: Mr. Andrew Jordan
Re: 197621; Asbestos
Eurofins EMLab P&K
17461 Derian Ave, Suite 100, Irvine, CA 92614
(866) 888-6653 Fax (623) 780-7695 www.emlab.com
Date of Sampling: 01-08-2020
Date of Receipt: 01-08-2020
Date of Report: 01-13-2020
ASBESTOS PLM REPORT
Location: 41, Exterior Building Paper Behind Wood Siding (East) Lab ID-Version: 11088945-1
Sample Layers Asbestos Content
Brown Paper ND
Composite Non-Asbestos Content: 45% Cellulose
Sample Composite Homogeneity: Moderate
Location: 42, Exterior Siding Caulking Lab 1D-Version1 11088946-I
Sample Layers Asbestos Content
White Caulk ND
Sample Composite Homogeneity: Moderate
Location: 43, Exterior Siding Caulking Lab 1D-Version: 11088947-1
Sample Layers Asbestos Content
White Caulk ND
Sample Composite Homogeneity: Moderate
Location: 44, Exterior Siding Caulking Lab ID-VersionS: 11088948-1
Sample Layers Asbestos Content
White Caulk ND
Sample Composite Homogeneity: Moderate
The test report shall not be reprdduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large
amounts of interference material and it is recommended that: the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2329884, Page 13 of 13
SAN DIEGO REGIONAL I OFFICE USE ONLY (
\)
HAZARDOUS MATERIALS IPLAN
I RECORD ID #________________________________
CHECK #
C OCR QUESTIONNAIRE BP DATE I I
Business Name Business Contact Telephone #
5•Tr So c L 7-(;o - ---- q
Project Address City / State Zip Code I APN#
a :cc1u, y IO3 5/-13
Mailing Address City State Zip Code I Plan File#
TO. Boç I2&- C'1i2Olf( P'./ TI/F- 5F4 I
Project Contact App(cant E-mail Telephone #
11iK I
The following questions represent the facility's activities, NOT the specific project description.
PART I: FIRE DEPARTMENT -HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: (not required for projects within the City of San
Diego): Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled,
applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal.
Occupancy Rating: Facility's Square Footage (including proposed project):
Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 13. Corrosives
Compressed Gases 6. Oxidizers 10. Cryogenics 14. Other Health Hazards
Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials
4 Flammable Solids 8. Unstable Reactives 12. Radioactives
questions is yes, applicant must contact the County or San Diego Hazardous Materials Division, 5500 overlana Avenue, suite ii U, bi
Call (858) 505-6700 prior to the issuance of a building permit.
FEES ARE REQUIRED Project Completion Date: Expected Date of Occupancy:
YES NO (for new construction or remodeling projects) 0 EI Is your business listed on the reverse side of this form? (check all that apply). 0 IiJ Will your business dispose of Hazardous Substances or Medical Waste in any amount? 0 EIJ Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500
L pounds and/or 200 cubic feet?
0 Will your business store or handle carcinogens/reproductive toxins in any quantity? 0 IfJ Will your business use an existing or install an underground storage tank? 0 ID Will your business store or handle Regulated Substances (CalARP)? 0 ID Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? 0 ID Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to
If the answer to any of the
Diego, CA 92123.
CalARP Exempt
Date Initials
CalARP Required
Date Initials
CalARP Complete
Date Initials
PART III: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCD): Any YES* answer requires a stamp from APCD 10124 Old Grove Road, San
Diego, CA 92131 apcdcomp(tt.sdcounty.ca.gov (858) 586-2650). [*No stamp required if Qi Yes and Q3 Yes and Q4-Q6 No]. The following questions are intended
to identify the majority of air pollution issues at the planning stage. Projects may require additional measures not identified by these questions. For comprehensive
requirements contact APCD. Residences are typically exempt, except - those with more than one building on the property; single buildings with more than four
dwelling units; townhomes; condos; mixed-commercial use; deliberate burns; residences forming part of a larger project. [Excludes garages & small outbuildings.]
YES NO
N 0 Will the project disturb 160 square feet or more of existing building materials? 0 ] Will any load supporting structural members be removed? Notification may be required 10 working days prior to commencing demolition. ] (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Has an asbestos survey been performed by a Certified Asbestos Consultant or Site Surveillance
Technician? 0 ] (ANSWER ONLY IF QUESTION 3 IS YES) Based on the survey results, will the project disturb any asbestos containing material? Notification
may be required 10 working days prior to commencing asbestos removal.
0 ] Will the project or associated construction equipment emit air contaminants? See the reverse side of this form or APCD factsheet
(www.sdaocd.org/info/facts/oermits.pdfl for typical equipment requiring an APCD permit.
0 .J (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school
Briefly describe business activities: Briefly describe proposed project:
Lfle/#IOIL 9 =_A (20 "—
I declare under penalty of perjury that to the best of my knowledge and belief tt e responsejMgle herein are true and correct.
ILl! ,1cL P .. '" / z °"
Name of Owner or Authorized Agent Signature of Owner or Authorized Agent Date
FOR OFFICAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:____________________________________________________________________
BY: DATE:
EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY
COUNTY-HMD APCD COUNTY-HMD APCD COUNTY-HMD APCD
FEB 052020
*A stamp in this box only exempts businesses from completing or updating a Hazardous Materials Business Plan. other permitting requirements may . still appiy.
HM-9171 (08/15) County of San Diego - DEH — Hazardous Materials Division
ELECTRONICS
29— Automated Soldering
42— Electronic Component Mfg
FOOD
12— Fish Canneries
12— Smoke Houses
50— Coffee Roasters
35— Bulk Flour & Powered Sugar Storage
SOLVENT USE
28— Vapor & Cold Degreasing
30— Solvent & Extract Driers
31 - Dry Cleaning
35— Bulk Dry Chemicals Storage
55— Chrome Electroplating Tanks
COATINGS & ORGANIC SOLVENTS
Coating & Painting
37— Plasma Arc & Ceramic Deposition Spray
Booths
38— Paint, Stain &. Ink Mfg
27— Printing
27— Polyester Resin/Fiberglass Operations
METALS
Metal Melting Devices
Oil Quenching & Salt Baths
32 - Hot Dip Galvanizing
39— Precious Metals Refining
ORGANIC COMPOUND MARKETING
(GASOLINE. ETC)
25— Gasoline & AlohoI Bulk Plants & Terminals
Intermediate Refueters
Gasoline & Alcohol Fuel Dispensing
OTHER
01 -Abrasive Blasting Equipment
03— Asphalt Roofing Kettles & Tankers
46— Reverse Osmosis Membrane Mfg
51 - Aqueous Waste Neutralization
11— Tire Buffers
17— Brake Debonders
23— Bulk Grain & Dry Chemical Transfer & Storage
45— Rubber Mixers
21 - Waste Disposal & Reclamation Units
36— Grinding Booths & Rooms
40— Asphalt Pavement Heaters
43— Ceramic Slip Casting
41 - Perlite Processing
40— Cooling Towers - Registration Only
91 - Fumigation Operations
56— WWTP (1 million gal/day or larger) & Pump
Station
LIST OF BUSINESSES WHICH REQUIRE REVIEW AND APPROVAL FROM THE COUNTY OF SAN DIEGO
DEPARTMENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISION
Check all that apply:
AUTOMOTIVE
Battery Manufacturing/Recycling
Boat Yard
Car Wash
Dealership Maintenance/Painting
Machine Shop
Painting
Radiator Shop
Rental Yard Equipment
Repair/Preventive Maintenance
Spray Booth
Transportation Services
Wrecking/Recycling
CHEMICAL HANDLING
Agricultural supplier/distributor
Chemical Manufacturer
Chemical Supplier/Distributor
Coatings/Adhesive
Compressed Gas Supplier/Distributor
Dry Cleaning
Fiberglass/Resin Application
Gas Station
Industrial Laundry
Laboratory
El Laboratory Supplier/Distributor
Oil and Fuel Bulk Supply
Pesticide Operator/Distributor
CHEMICAL HANDLING
Photographic Processing
Pool Supplies/Maintenance
Printing/Blue Printing
Road Coatings
Swimming Pool
Toxic Gas Handler
Toxic Gas Manufacturer
METAL WORKING
Anodizing
Chemical Milling/Etching
Finish-Coating/Painting
Flame Spraying
Foundry
Machine Shop-Drilling/Lathes/Mills
Metal Plating
Metal Prepping/Chemical Coating
Precious Metal Recovery
Sand Blasting/Grinding
Steel Fabricator
Wrought Iron Manufacturing
AEROSPACE
Aerospace Industry
Aircraft Maintenance
Aircraft Manufacturing
OTHERS AND MISCELLANEOUS
Asphalt Plant
Biotechnology/Research
Chiropractic Office
Co-Generation Plant
O Dental Clinic/Office
Dialysis Center
Emergency Generator
Frozen Food Processing Facility
Hazardous Waste Hauler
Hospital/Convalescent Home
Laboratory/Biological Lab
Medical Clinic/Office
Nitrous Oxide (NO.) Control System
Pharmaceuticals
Public Utility
Refrigeration System
Rock Quarry
Ship Repair/Construction
Teleèommunications Cell Site
Veterinary Clinic/Hospital
Wood/Furniture Manufacturing/Refinishing
ELECTRONICS
Electronic Assembly/Sub-Assembly
Electronic components Manufacturing
Printed Circuit Board Manufacturing
NOTE: THE ABOVE LIST INCLUDES BUSINESSES, WHICH TYPICALLY USE, STORE, HANDLE, AND DISPOSE OF HAZARDOUS SUBSTANCES.
ANY BUSINESS NOT INCLUDED ON THIS LIST, WHICH HANDLES, USES OR DISPOSES OF HAZARDOUS SUBSTANCES MAY STILL REQUIRE
HAZARDOUS MATERIALS DIVISION (HMD) REVIEW OF BUSINESS PLANS. FOR MORE INFORMATION CALL (858) 505-6880.
LIST OF AIR POLLUTION CONTROL DISTRICT PERMIT CATEGORIES
Businesses, which include any of the following operations or equipment, will require clearance from the Air Pollution Control District.
CHEMICAL
47— Organic Gas Sterilizers
32 - Acid Chemical Milling
33— Can & Coil Manufacturing
44— Evaporators, Dryers & Stills Processing
Organic Materials
24— Dry Chemical Mixing & Detergent Spray
Towers
COMBUSTION
34— Piston Internal - Combustion Engines
Boilers & Heaters (1 million BTU/hr or larger)
Incinerators & Crematories
Burn Out Ovens
16:- Core Ovens
20— Gas Turbines, and Turbine Test Cells & Stands
48— Landfill and/or Digester Gas Flares
ROCK AND MINERAL
Hot Asphalt Batch Plants
Rock Drills
Screening Operations
Sand Rock & Aggregate Plants
Concrete Batch, CTB, Concrete Mixers, Mixers
& Silos.
10— Brick Manufacturing
NOTE: OTHER EQUIPMENT NOT LISTED HERE THAT IS CAPABLE OF EMITTING AIR CONTAMINANTS MAY REQUIRE AN AIR POLLUTION
CONTROL DISTRICT PERMIT. IF THERE ARE ANY QUESTIONS, CONTACT THE AIR POLLUTION CONTROL DISTRICT AT (858) 586-2600.
HM-9171 (08/15) County of San Diego - DEH - Hazardous Materials Division
4
ENCINA WASTEWATER AUTHORITY
INDUSTRIAL WASTEWATER DISCHARGE PERMIT
SCREENING SURVEY
6200 Avenida Encinas, Carlsbad, CA 92011
Phone: 760-438-3941 Fax: 760-476-9852
SourceControl@encinajpa.com
Date:oz/c4o
Business Name:£W7T CWV'.79uT1Vk.i So C#/
StreetAddress: PO,ci 1Z4 CppPP Rv 7II SE4
Email Address: Sto77-c7yLvc.,7lL,4/, &fl 0
PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT: (ON REVERSE SIDE CHECK TYPE OF BUSINESS)
Check all below that are present at your facility:
'0 Acid Cleaning
o Assembly
o Automotive Repair
o Battery Manufacturing
o Biofuel Manufacturing
o Biotech Laboratory
o Bulk Chemical Storage
o Car Wash
o Chemical Manufacturing
o Chemical Purification
o Dental Offices
Dental Schools
Dental Clinics
o Dry Cleaning
o Electrical Component
Manufacturing
o Fertilizer Manufacturing
o Film/X-ray Processing
Food Processing o Metal Powders Forming
Glass Manufacturing o Nutritional Supplement/Vitamin
Industrial Laundry Manufacturing
Ink Manufacturing o Painting/Finishing
Laboratory o Paint Manufacturing
Machining/Milling o Personal Care Products
Membrane manufacturing Manufacturing
(i.e. water filter membranes) o Pesticide Manufacturing/ Packaging
Metal Casting/Forming o Pharmaceutical Manufacturing
Metal Fabrication (including precursors)
Metal Finishing o Porcelain Enameling
Electroplating o Power Generation
Electroless Plating o Print Shop
Anodizing o Research and Development
Coating (i.e. phosphating) o Rubber Manufacturing
Chemical Etching/Milling o Semiconductor Manufacturing
Printed Circuit Board o Soap/Detergent Manufacturing
Manufacturing o Waste Treatment/Storage
New Business? Yes[] No[] SIC Code(s) if known: Date operation began/will begin:__________________
Tenant Improvement? Yes 0 No[] If yes, briefly describe improvement:
Description of operations generating wastewater (discharged to sewer, hauled or evaporated):
Estimated volume of industrial wastewater to be discharged (gal/ day):
List hazardous wastes generated (type/volume):
Have-you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority? Yes 0 Date: No 11
Page 1 of 2
ENCINA WASTEWATER AUTHORITY
INDUSTRIAL WASTEWATER DISCHARGE PERMIT
SCREENING SURVEY WAMMATTR
6200 Avenida Encinas, Carlsbad, CA 92011 -.
Phone: 760.438-3941 Fax: 760-476-9852
SourceControI@encinajpa.com
The commercial enterprises listed below are a partial listing of businesses that are exempt from industrial wastewater
discharge permitting under normal operating conditions. They are exempt because (a) they discharge no process wastewater
(i.e., they only discharge sanitary wastewater with no pollutants exceeding any local limits), and (b) they have no potential to
negatively impact the EWPCF or other wastewater treatment plants in the ESS. Any questions regarding exemptions
should be referred to EWA Source Control staff.
Automobile Detailers
Barber/Beauty Shops
5? Offices
Cleaning Services
Carpet/Upholstery
Childcare Facilities
Churches
Community Centers
Consulting Services
Contractors
Counseling Services
Educational Services (no auto repair/film developing)
Financial Institutions/Services
Fitness Centers
Gas Stations (no car wash/auto repair)
Grocery Stores (no film developing)
Residential based Businesses
Hotels/Motels (no laundry)
Laundromats
Libraries
Medical Offices (no x-ray developing)
Mortuaries
Museums
Nail Salons
Nursing Homes
Office Buildings (no process flow)
Optical Services
Pest Control Services (no pesticide repackaging for sale)
Pet Boarding/Grooming Facilities
Postal Services (no car wash/auto repair)
Public Storage Facilities
Restaurants/Bars
Retail/Wholesale Stores (no auto repair/film developing)
Theaters (Movie/Live)
CERTIFICATION STATEMENT
I certify that the information above is true and correct to the best of my knowledge.
Signature4-169; Print Name:WICWthL PfE' DATE:_______z 0 ____
Facility Contact: Title:________________________________________
ENCINA WASTEWATER AUTHORITY
6200 AVENIDA ENCINAS, CARLSBAD, CA Phone: 760-438-3941 Fax: 760-476-9852
SourceControl@encinaipa.com
Page 2 of 2
0 loci ot I •com
(City of
Carlsbad
CLIMATE ACTION PLAN
CONSISTENCY CHECKLIST
B-50
Development Services
Building Division
1635 Faraday Avenue
(760) 602-2719
www.carlsbadca.gov
PURPOSE
This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance
requirements apply to their projects. The completed checklist must be included in the building permit application. It may be
necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate
full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach
to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as
specified by the ordinances.
NOTE: The following type of permits are not required to fill out this form
:• Patio + Decks I •• PME (w/o panel upgrade) J + Pool
4 If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance,
an explanation must be provided to the satisfaction of the Building Official.
4 Details on CAP ordinance requirements are available on the city's website.
4 A CAP Building Plan template (form B-55) shall be added to the title page all building plans. This template shall be
completed to demonstrate project compliance with the CAP ordinances. Refer to the building application webpaQe and
download the latest form.
Application Information
Project Name/Building
Permit No.: BP No.:
Property Address/APN: z'tlo c-i.,J r / - ApplicantName/Co.: p/ 6H'I/// dWkinff 44A U2
Applicant Address: cx f2o/ 0.A,i/4 1M .H cA - Y-o 75- ,rr --- r—
Contact Phone: Contact Email:
•
Contact information of person completing this checklist (if different than above):
Name: j::r3/ 11(J/_.LE1CJ Contact Phone:
Company
name/address: _______ Lkf2 ontact WMIPIN&
_AA. d4 .I1 Date:X I/3 /)
B-50 Page 1 of 6 Revised 08/19
City of Carlsbad Climate Action Plan Consistency Checklist
Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project.
For alterations and additions to existing buildings, ttach Building Permit Valuation worksheet
Building Permit Valuation (BPV) [from workshee $________________
I Construction Type
-
Complete Section(s) Notes: -
A high-rise residential building is 4 or more stories, including a
Residential Low-rise High-rise mixed-use building in which at least 20% of its conditioned floor
area is residential use
0 New construction
2A, 3A, 1B 213,
4A
,
313 4A
O Additions and alterations:
BPV < $60,000 N/A N/A All residential additions and alterations
BPV ~: $60,000 1A 4A 4A 1-2 family dwellings and townhouses with attached garages
O Electrical service panel upgrade only ' only
*Multi-family dwellings only where interior finishes are removed
BPV a $200,000 1A, 4A* 1 B, 4A* and significant site work and upgrades to structural and
mechanical, electrical, and/or plumbing systems are proposed
Nonresidential
O New construction 1 B, 2B, 3B, 46 and 5
Alterations: N4. 4EX AZWE. -WA-T*1-/cM V4VdJ-ie*J -/7,c?
BPV ~! $200,000 or additions a 1,000 1B, 5 square feet
BPV 2:$1,000,000 113, 2B, 5 Building alterations of 2: 75% existing gross floor area
0 2t 2,000 sq. ft. new roof addition I 2B, 5 1 B also applies if BPV 2: $200,000
CAP Ordinance Compliance
Checklist Item
Check the appropriate boxes, explain all not applicable and exception items, and provide supporting calculations and documentation as necessary.
1. Energy Efficiency
Please refer to Casbad Municipal Code (CMC) sections 18.21.155 and 18.30.190, and the California Green Building Standards Code (CALGreen) for
more information when completing this section.
A 0 Residential addition or alteration $60,000 building permit valuation. O N/A
See CMC section 18.30.190. o Exception: Home energy score a 7
(attach certification)
Year Built Single-family Requirements Multi-family Requirements
Before 1978 Select one:
Duct sealing 0 Attic insulation 0 Cool roof 0 Attic insulation
1978 and later Select one: O Lighting package 0 Water heating Package
Between 1978 and 1991 Select one:
Duct sealing 0 Attic insulation 0 Cool roof
1992 and later Select one: Lighting package 0 Water heating package
B. 0 Nonresidential* new construction or alterations $200,000 building permit valuation,
or additions 1,000 square feet XNIA
Updated 8/1512019 2
City of Carlsbad Climate Action Plan Consistency Checklist
See CIVIC 18.21.155 and CALGreen Appendix A5, Division A5.2 - Energy Efficiency.
A5.203.1.1 Choose one: 0.1 Outdoor lighting 0.2 Warehouse dock seal doors
0 .3 Restaurant service water heating (comply with California Energy Code section 140.5, as amended)
0.4 Daylight design PAR 0.5 Exhaust air heat recovery
C)
Choose one as applicable: 0.95 Energy budget 0.90 Energy budget N/A_____________________________
A5.211.1"
o On-site renewable energy
A5.211.3**
0 Green power (if offered by local utility provider, 50% minimum renewable sources) N/A_____________________________
A5.212.1
0 Elevators and escalators X N/A___________________________
A5.213.1
0 Steel framing N/A_______________________
tIncludes hotels/motels and high-rise residential buildings
For alterations a $1,000,000 BPV and affecting >75% existing gross floor area, or alterations that add 2,000 square feet of new roof addition: comply
with CIVIC 18.30.130 instead.
-
0 Residential new construction (for low-rise residential building permit applications submitted after 111120). Refer to 2019 California
Energy Code section 150.1(c)14 for requirements. Notes: 1) High-rise residential buildings are subject to nonresidential photovoltaic
requirement (213 below) instead. 2) If project includes installation of an electric heat pump water heater pursuant to CIVIC 18.30.150(B)
(high-rise residential) or 18.30.170(8) (low-rise residential), increase system size by .3kWdc if PV offset option is selected.
Floor Plan ID (use additional
sheets if necessary)
CFA #d.u. Calculated kWdc* Exception
0
0
Total System Size: kWdc
kWdc = (CFAx.572) / 1,000+ (1.15 x #d.u.)
*Formula calculation where CFA = conditional floor area, #du = number of dwellings per plan type
If proposed system size is less than calculated size, please explain.
Nonresidential new construction or alterations 41,000,000 BPV and affecting ?75% existing floor area, or addition that increases roof
area by ?2,000 square feet Please refer to CIVIC section 18.30.130 when completing this section. Note: This section also applies to
high-rise residential and hotel/motel buildings.
Choose one of the following methods:
O Gross Floor Area (GFA) Method
GFA: Mm. System Size: kWdc
0 If < 10,000s.f. Enter: 5 kWdc
0 If ~ 10,000s.f. calculate: 15 kWdc x (GFNI0,000)
Round building size factor to nearest tenth, and round system size to nearest whole number.
0 Time- Dependent Valuation Method
Updated 8/15/2019
City of Carlsbad Climate Action Plan Consistency Checklist
Annual TDV Energy use:' x.80= Mm. system size: kWdc
Attach calculation documentation using modeling software approved by the California Energy Commission.
3. Water Heating
A 0 Residential and hotel/motel new construction
Please refer to CIVIC sections 18.30.150 and 18.30.170 when completing this section.
O For systems serving individual dwelling units choose one:
Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise
residential only)
Heat pump water heater AND PV system .3 kWdc larger than required in CIVIC section 18.30.130 (high rise
residential hotel/motel) or CA Energy Code section 150.1(c) 14 (low-rise residential)
O Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher
O Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors
O Exception:
O For systems serving multiple dwelling units, install a central water-heating system with all of the following:
Gas or propane water heating system
Recirculation system per CIVIC 18.30.150(B) (high-rise residential, hotel/motel) or CIVIC 18.30.170(B) (low-
rise residential)
O Solar water heating system that is either:
.20 solar savings fraction
O .15 solar savings fraction, plus drain water heat recovery
Exception:
B. 0 Nonresidential new construction
Please refer to Carlsbad Ordinance CIVIC section 18.30.150 when completing this section.
O Water heating system derives at least 40% of its energy from one of the following (attach documentation):
O Solar-thermal 0 Photovoltaics 0 Recovered energy
O Water heating system is (choose one):
O Heat pump water heater
0 Electric resistance water heater(s)
OSolar water heating system with .40 solar savings fraction
0 Exception:
Updated 8/15/2019 4
City of Carlsbad Climate Action Plan Consistency Checklist
A Residential New construction and major alterations*
Please refer to Carlsbad Ordinance CMC section 18.21.140 when completing this section.
0 One and two-family residential dwelling or townhouse with attached garage:
0 One EVSE Ready parking space required 0 Exception:
0 Multi-family residential: 0 Exception:
Total Parking Spaces
Proposed
EVSE Spaces
Capable Ready Installed Total
Calculations: Total EVSE spaces =.10 x Total parking (rounded up to nearest whole number)
EVSE Installed = Total EVSE Spaces x.50 (rounded up to nearest whole number)
EVSE other Total EVSE spaces - EVSE Installed
(EVSE other may be "Capable," "Ready" or "Installed.")
*Major alterations are: (1) for one and two-family dwellings and townhouses with attached garages, alterations have a building pemift valuation 2 $60,000
or include an electrical service panel upgrade: (2) for multifamily dwellings (three units or more without attached garages), aRerabons have a building permit
valuation 2 $200,000, interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing
systems are proposed.
B. Nonresidential new construction (includes hotels/motels) , Exception: (t.. MI)Jft 1FWW)ti 1.'
Total Parking Spaces I EVSE Spaces
Read Installed Total
Calculation: Refer to the table below:
Total Number of Parking Spaces provided Number of required EV Spaces Number of required EVSE Installed Spaces
0-9 1 1
10-25 2 1
26-50 4 2
51-75 6 3
76-100 9 5
101-150 12 6
151-200 17 9
201 and over 10 percent of total 50 percent of Required EV Spaces
Updated 8/15/2019 5
City of Carlsbad Climate Action Plan Consistency Checklist
5. [:1 Transportation Demand Management (TDM): Nonresidential ONLY A74Ct%'I7 EMA-J
An approved Transportation Demand Management (TDM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT.
City staff will use the table below based on your submitted plans to determine whether or nor your permit requires a TDM plan. If TDM is applicable to your
permit, staff will contact the applicant to develop a site-specific TDM plan based on the permit details.
Employee ADT Estimation for Various Commercial Uses
Use first Li. !W 1 000J!!7J
Office (afl)2 -
20 13
Restaurant 11 11
Retaib 8 4.5
-
Industrial 3.5
Manufacturing_ 4 3
-
Warehousing 4 1
i Unless otherwise noted, rates estimated from ITE Trip
Generation Manual, lOthEdition
2 For all office uses, use SANDAG rate of 20 ADT/1 ,000 sf to
calculate employee ADT
3 Retail uses include shopping center, variety store, supermarket,
gyms, pharmacy, etc.
Other commercial uses may be subject to special
consideration
-Sample calculations:
Office: 20,450 sf
1. 20,450 sf/1000 x 20 = 409 Employee ADT
Retail: 9,334 sf
First 1,000 sf=8ADT
9,334sf- 1,000 sf = 8,334 sf
(8,334 sf/1,000 x 4.5) + 8 = 46 Employee ADT
Acknowledgment:
I acknowledge that the plans)thitted may be subject to the City of Casbad's Transportation Demand Management Ordinance. I agree to be contacted should
my permit require a TDM pl(r(\nderstand that an approved TDM plan is a condition of permit issuance.
Applicant sinature:,X Date)<
Person other than Applicant to be contacted for TDM compliance (if applicable):
Name (Printed): 4 (1LLJis)
Email Address: d#21A Phone Number66 9 R-74;
Updated 8/15/2019
PERMIT REPORT
(rcity of
Carlsbad
Print Date: 05/28/2020 Permit No: PREV2020-0025
2910 Jefferson St
BLDG-Permit Revision
2033541300
$ 0.00
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Bathrooms:
Project Title:
Description:
Work Class: Commercial Permit Revi5 Status: Closed - Finaled
Applied: 02/11/2020
Lot #: Issued: 04/14/2020
Project #: PermitFinal
Construction Type Close Out: 05/28/2020
Inspector:
Orig. Plan Check #: CBC2019-0558 Final
Plan Check #: Inspection:
ORANGE LAND HOLDINGS LLC: ADD WOOD PLATFORM @ WHEELCHAIR LIFT// REVISE SOME WINDOWS AND SIDING
Applicant: Owner: Contractor:
ORANGE LAND HOLDINGS LLC ORANGE LAND HOLDINGS LLC NORTH COUNTY CONSULTING INC
DON GLATHORN
264 Pacific Ave 1204 2043 San Elijo Ave
SOLANA BEACH, CA 92075-0000 CARLSBAD, CA 92075 Cardiff by the Sea, CA 92007-1726
619-920-6564 .
858-799-0688.
FEE AMOUNT
BUILDING PLAN CHECK REVISION ADMIN FEE $35.00
MANUAL BLDG PLAN CHECK FEE . $450.00
Total Fees: $ 485.00 Total Payments To Date: $ 485.00 Balance Due: $0.00
Building Division
1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-2700 1 760-602-8560 f I www.carlsbadca.gov Page 1 of 1
(City of
Carlsbad
PLAN CHECK REVISION OR
DEFERRED SUBMITTAL
APPLICATION
B-15
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
PREv2020-0025 Original Plan Check Number 151- ZoI- o96 Plan Revision Number i..rA 432.
Project Address 21 /0 cjff&zJcI) cr• ttcpj e4.
General Scope of Revision/Deferred Submittal: AQL 44 Po_,±L4q.11JZk.dL41J&_.
O,Oa4a
CONTACT INFORMATION:
Name_'posv &JA=k4A Aj Phone (ti) Fax_______________
Address _-a /?-if City .Zip ' 2o7
Email Address A9 .0 . 7r1%o*S t pzLLL&w
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person.
1. Elements revised: f'Plans Calculations D Soils E3'Energy 0 Other
2.
Describe revisions in detail
3.
List page(s) where each
revision is shown
'QO ,s j4,1/1W120U4W &Joob Pi'1 11r a'r. 'ma.cswz LIprArR6 A3
MusE pL..pocO sci0iO4 4LAcs o9oiLq 7P &J,'Oo&i
V
AI-t, At-, Az.,
Al2-s iUwfv )'WoL1,I sr 1$14t MOVOIN4 7D 0"0. k1JAH3Di11S (lct1 I'!INOiS
gcit ç'iI lJdAWJS) i1 4 2- r, Az
iW"s jltLCNCH 0o044 47 opr• LifT 4c f12us4 1EDNT PC1 iIE)/L DCk 4f pia'cr LtuCL ID 'a.)o MCn't OoeiU A:-it , At-(.
4evs(e %.p'StD fivft Pout j V&o4 C.tUP.SOit 7D 4(412 Qft)t 6ACJL 70 J. 1aJ'D'J
4 I)eP.4rg 3.7'o fix wougooa ag4w U.so J,NOO&J Ar 5((4.'Jo t.fVL e.s41,Opit
l2 1. AZ.(.
114/!
Does this revision, in any way, alter the exterior of the project? ['Yes 0 No
Does this revision add ANY new floor area(s)? D Yes El' No
Does this revision affect any fire related issues? 0 Yes El' No
Is this a comp1Met? El' Yes 0 No
Date LQ Ya17 61a 1635 Faraday Avenue, Carlsbad, CA 92008 Ph: 760-602-2719 f: 760-602-8558 Email: building@carlsbadca.gov
www.carlsbadcagov
EsCail
A SAFEbuRtCompany 1
DATE: MAR. 09, 2020 LJ APPLICANT
JURIS.
JURISDICTION: RLiSffA)
PLAN CHECK #.: CBC201:9-0558 (REV.-1) - PREV2020-0025_ SET: II
PROJECT ADDRESS: 2910 JEFFERSON STREET
PROJECT NAME: ORANGE LAND HOLDINGS, LLC - FACADE REMODEL
f1 The plans transmitted herewith have been corrected where necessary and substantially comply
' with the jurisdiction's codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
El The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
EsGil staff did not advise the applicant that the plan check has been completed.
EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Don Glatthorn Telephone #: 619-920-6564
Date contacted:.qO (by:C,) Email: deg.northcoast(äqmail.com
Mail Telephone Fax In Person
REMARKS: Il:bepressure:teiated
Owner's revisions, replacement sets are submitted for review & approval.
By: ALl SADRE, S.E. Enclosures: Approved plans.
EsGil
3/3
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576
I
EsGil
A SAFEbuit(Company
DATE: FEB. 209 2020 L3 APLICANT
A JURISDICTION: CARLSBAD
ei
PLAN CHECK #.: CBC2019-0558 (REV.-1) - PREV2020-0025_ SET: I
PROJECT ADDRESS: 2910 JEFFERSON STREET
PROJECT NAME: ORANGE LAND HOLDINGS, LLC - FAADE REMODEL
EJ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
fl The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
fl EsGil staff did not advise the applicant that the plan check has been completed.
EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Don Glatthorn Telephone #: 619-920-6564
Date contacted:\(l: Email: dep.northcoastcpmail:com
Mail Telephone Fax In Person
REMARKS: Owner's revisions, replacement sets are submitted for review & approval.
By: ALl SADRE, S.E. Enclosures:
EsGil
2/13
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576
CARLSBAD CBC2019-0558 (REV.-1) - PREV2020-0025
FEB. 20, 2020
GENERAL
Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted in one
of two ways:
Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700.
The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire
Departments.
Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake
Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of
plans and calculations/reports directly to the City, of Carlsbad Building Department for
routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City
Planning, Engineering and Fire Departments until review by EsGil is complete.
2. To facilitate rechecking, please identify, next to each item, the sheet of the
plans upon which each correction on this sheet has been made and return
this sheet with the revised plans.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located on the plans. Have changes been
made not resulting from this list? U Yes U No
PLANS
Please revise Sheets A2-2 & A2-5 to show 48" separation between doors in
series. CBC, Figure 11 B-404.2.6(a). Add to the separation between the platform
gate and the side entry door (tagged with keynotes #23 & #7).
STRUCTURAL
Please provide foundation and framing plans with calculations for the lift and the
deck between the lift and the side entry doors.
Please include railing support connection details & references on the plans at the
new deck.
MISCELLANEOUS
The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to
perform the plan review for your project. If you have any questions regarding
these plan review items, please contact ALl SADRE, S.E. at EsGil. Thank you.
CARLSBAD CBC2019-0558 (REV.-1) - PREV2020-0025
FEB. 20, 2020
[DO NOT PAY - THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: CARLSBAD PLAN CHECK #.: CBC2019-0558
(REV.-1) - PREV2020-0025
PREPARED BY: ALl SADRE, S.E. DATE: FEB. 20, 2020
BUILDING ADDRESS: 2910 JEFFERSON STREET
BUILDING OCCUPANCY: B/8-2; V-B/SPR.
BUILDING
PORTION
AREA
(Sq. Ft.)
Valuation
Multiplier
Reg.
Mod.
VALUE ($)
PLAN
REVISIONS
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code ICB 113Y *Ordinance
1
1997 UBC Building Permit Fee
Al -l:
11997 UBC Plan Check Fee Lml
I At
Type of Review: r Complete Review
r Repetitive r Other
Repeats Hourly
EsGil Fee
r r Based on hourly rate
r Structural Only
31Hrs.*
$120.00 I
$360.00
Comments:
Sheet 1 of 1
S T -\ R' % M"00* K
Architecture + Planning
CITY OF ENCINITAS PLANNING AND BUILDING DEPARTMENT PLAN CHECK CORRECTIONS RESPONSES
Date: 02/27/2020
Project Name: 2910 JEFFERSON STREET
SAAP Job #: 2018036
Plan Reviewer: All Sadre
Plan Check Number: PC# CBC2019-0558 I PREV2020-0025
We have responded to Plan Review Correction List. All revisions are clouded and
noted as delta #3.
GENERAL
Acknowledged.
Done.
None.
PLANS
RECE!,ED
[MAR O4 2020
UILDING DIVISION
See revised plan sheet A2-2 and revised elevations sheets A2-5 and A2-6.
STRUCTURAL
S. See added landing sheet 52.
See added details 14 and 15 sheet SD-1 and structural calculations.
MISCELLANEOUS
Acknowledged.
Cordially,
Bafiram 7v1àJieronnagfis/i
Architect / Starck Architecture + Planning
Page 11
- - -
STRUCTURAL PLAN CHECK RESPONSES
DATE:
PROJECT:
PROJECT No.:
PLAN CHECK No.:
February 27, 2020
Jefferson Street
19-421
CBC20 19-0558
HTK
STRUCTURAL ENGINEERS, LLP
See calculations and details for lift framing.
Railing calculation added. Straps added to show how the handrail post is supported.
RECEIVED
MAR 02 2020
CITY OF CARLSBAD
BUILDING DIVISION
From: Ben Seibel
Copies to: File • 40 0
5 IPage 1
HTK STRUCTURAL ENGINEERS. UP
www.htkse.com
PROJECT: -
DESIGNER
b-z s>- -1; -w
(,,-- 5, f ,
((2(f(z
v- (2
M:(o3-' pf -4b
Ajl HTK
STRUCTURAL ENGINEERS. LLP
www.htkse.com
SHEET: -_-
PROJECT:
DESIGNER
-
I
st1 -7
,rn)