Loading...
HomeMy WebLinkAboutPRE 2018-0031; BABILONIA STREET SINGLE FAMILY RESIDENCE; Admin Decision LetterNovember 14, 2018 Steve Scordel 3224 Canyon View Drive Oceanside, CA 92058 ~\e,J \~.,~-,~ 8FllE COPY Ccityof Carlsbad SUBJECT: PRE 2018-0031 {DEV2018·0189)-BABILONIA STREET SINGLE FAMILY RESIDENCE APN: 21S-440·19·00 Thank you for submitting a preliminary review for a new single-family residence project proposed at 7203 Babilonia Street. The project site, an approximately 77,667 square-foot lot, is currently undeveloped. In response to your application, the Planning Division has prepared this comment letter. Please note that the purpose of a preliminary review is to provide you with direction and comments on the overall concept of your project. This preliminary review does not represent an in-depth analysis of your project. It is intended to give you feedback on critical issues based upon the information provided in your submittal. This review is based upon the plans. policies. and standards in effect as of the date of this review. Please be aware that at the time of a formal application submittal. new plans. policies. and standards may be in effect and additional issues of concern may be raised through a more specific and detailed review. Planning: General 1. General Plan and zoning designations for the property are as follows: a. General Plan: Residential 0·1.5 (R-1.5), 0-1.5 units/ac. Growth Management Control Point of 1 unit per acre. b. Zoning: R-1·15000 c. Master Plan: La Costa Master Plan, MP 149 d. The property is not located in the Coastal Zone. e. The property is located within the Airport Land Use Compatibility Plan's (ALUCP) Airport Influence Review Area 2 2. The project requires the following permits: a. Building permit b. Grading permit c. Landscaping plan review 3. Per MP 149, the site's zoning means that the project is subject to all development regulations for the R·l zoning district as prescribed in Carlsbad Municipal Code (CMC) Section 21.10. Specific development requirements are as follow: Community & Economic Development Planning Division I 1635 Faraday Avenue Carlsbad, CA 92008-7314 I 760-602-4600 I 760-602-8560 f I www.carlsbadca.gov PRE 2018-0031 (DEV2018-0189)-BABILONIA STREET SINGLE FAMILY RESIDENCE November 14, 2018 Pa e 2 a. Lot Coverage: Maximum 40 percent of lot area. b. Setbacks: -Front: 20 feet -Sides: 10 feet -Rear: 20 feet (the Habitat Management Plan standards referenced below may require a greater setback adjacent to native habitat) c. Height: Maximum 35 feet/two stories (minimum roof pitch is 3:12). 4. Pursuant to CMC Section 21.95.040, the site is a hillside lot but the project is exempt from obtaining a Hillside Development Permit if it complies with all hillside development standards as prescribed in CMC Section 21.95.140: 5. The site abuts an existing hardline preserve and Linkage Area E per Carlsbad's Habitat Management Plan (HMP). The project is subject to Adjacency Standards per HMP Section F(3). This includes provisions related to fire management, erosion control, landscaping, fencing, signs, lighting and predator/exotic species. A biology letter shall be submitted to determine if the project has direct or indirect impacts on off-site or native habitat, which will require submittal of a Habitat Management Permit pursuant to CMC Section 21.210.030. The HMP is available through the following link: http://www.carlsbadca.gov/civicax/fi1ebank/blobdload.aspx?Blob1D=27193 6. Please refer to the City of Carlsbad's Landscape Manual (link below) for specific landscaping policies and requirements. http:ljwww.carlsbadca.gov/civicax/filebank/blobdload.aspx?Blob1D-24086 7. Pursuant to CMC Sections 21.85.030 and 21.85.110, the proposed project is subject to inclusionary housing requirements since there is a net gain of one dwelling unit. The developer has the option to satisfy the requirement through the payment of a housing in-lieu fee on a per unit basis for one unit. 8. The property is located within the ALUCP's Airport Influence Review Area 2, but it is not subject to any noise, safety, or overflight notification requirements of the current ALUCP. All necessary application forms, submittal requirements, and fee information are available at the Planning counter located in the Faraday Building at 1635 Faraday Avenue or online at http://www.carlsbadca.gov/services/depts/planning/default.asp. You may also access the General Plan Land Use Element and the Zoning Ordinance online at the website address shown; select Department Listing; select Planning Home Page. Please review all information carefully before submitting. Land Development Engineering: 9. Complete a Stormwater Standards Questionnaire. This questionnaire will guide you and the City in determining what type of reports and storm water mitigation must be completed to satisfy state and City storm water quality requirements. The questionnaire can be printed from the following website link: http://www.carlsbadca.gov/civicax/filebank/blobd1oad.aspx?Blob1D 22711 PRE 2018-0031 (DEV2018-0189)-BABILONIA STREET SINGLE FAMILY RESIDENCE November 14, 2018 Pa e 3 Preliminary analysis suggests that the project is a Priority Development Project (PDP) and subject to installing numerically sized structural BMPs per Chapter 5 of the Carlsbad BMP Design Manual in addition to site design and source control BMPs per Chapter 4 of the Carlsbad BMP Design Manual. The project is likely a PDP since it involves more than 2,500 square feet of new impervious surface that drains to an environmentally sensitive area (ESA). The area within the abutting SDG&E easement has been classified as an ESA. The project would also be subject to hydromodification (See Chapter 6). No critical course sediment yield areas exist on the property per the WMAA. Unless the project can be redesigned so that it is no longer determined to be a PDP, submit a Storm Water Quality Management Plan (SWQMP) with your application for grading plan check. Use the City of Carlsbad SWQMP template (Form E-35) available on the City website. 10. A Preliminary Title Report (PTR) will be required with formal project application submittal. All easements and encumbrances identified in Schedule "B" of the PTR must be indicated on the site plan. 11. Submit a Geotechnical Study that provides recommendations for the proposed development including design recommendations for any proposed pollutant control BMPs as well as surface drainage. Additional plan check fees will apply for third party review of the report during grading plan check. 12. On the site plan, show locations and identify sizes of all existing utilities (including water main, fire hydrant, water services, water meters, sewer main, sewer laterals, and their appurtenances). Reference the drawing numbers of the city approved improvement plans for the existing utilities. 13. The project is located within the Carlsbad Municipal Water District (CMWD). Show the locations of domestic water service and water meters with backflow preventers on the grading plan. Note that all backflow preventers must be located outside the public right-of-way. Water service and meter shall be installed per CMWD Stnd DWG W-3A. This standard requires a one inch meter to ensure adequate flow for fire sprinklers. 14. The project is located within the Leucadia Wastewater District (LWD). Contact LWD early in the process as they may require that you submit an application for plan check. Plot location of sewer lateral and any existing sewer facilities on the property and label as 'by separate permit from LWD'. Be aware that a 10-foot wide sewer easement per Map 7367 traverses the property and this easement and any facilities within it appear to conflict with the location of the proposed house. However, this cannot be verified until adequate grading plans with plotted easement and facilities are prepared. LWD will determine if the proposal conflicts with their easement and facilities. 15. A grading permit will be required for the proposed development. Indicate the volume of grading (cut, fill, import, export, remedial) proposed for the project in cubic yards. Show all proposed grading via proposed contours, spot elevations, flow line elevations, etc. Identify any trees on the property and clarify whether they will be removed or remain. 16. Show existing structures, contour lines and/or spot elevations onsite and adjacent properties. Include adjacent property grades; spot elevations, walls, landscaping and any other structures within 25 to 50 feet of the subject property and plot direction of drainage flow. Any drainage flow currently flowing onto the property will need to be addressed so that flow is not impeded. Provide multiple cross sections at the property line to illustrate any grade differential between properties. ----------------·------·--·--·- PRE 2018-0031 (DEV2018-0189)-BABILONIA STREET SINGLE FAMILY RESIDENCE November 14, 2018 Pa e 4 17. Identify all wall heights with top of wall and bottom of wall elevations. Include structural notes and details for any custom design retaining walls which must be shown on the grading plan. Structural wall calculations must be submitted for review with the plans. Additional plan check fees will apply for said review. 18. Show proposed landscape irrigation service and water meter with backflow preventer per CMWD W- 20. 19. Curb and gutter exists on Babilonia St. frontage but not sidewalk. Property owner will be required to enter into a future improvement agreement (FIA) to install sidewalk at a future date uncertain if required by the city. If you would like to schedule a meeting to discuss this letter with the commenting departments, please contact Esteban Danna at the number below. You may also contact each department individually as follows: • Planning Division: Esteban Danna, Associate Planner, at 760-602-4629 • Land Development Engineering: David Rick, Associate Engineer, at 760-602-2781 • Fire Department: Randall Metz, Fire Inspections, at 760-602-4661 Sincerely, DON NEU, AICP City Planner DN:ED:dh c: Yayu L. Tu, 13 Shelburne Drive, Oak Brook, IL 60523 David Rick, Project Engineer Fire Prevention HPRM/File Copy Data Entry