HomeMy WebLinkAboutCD 09-07; BRESSI RANCH MEDICAL PLAZA; Consistency Determination' '-'"
-;;.s--
C w
a:
0 z -:E
C u
..I w
CONSISTENCY DETERMINATION CD 09-07 5/21/09 SEWER~UBLIC SERV~:::~NCIES
i?(
I
I
I
I
I
I
f
,.
f, 1' ti ... LJ
I //
I / /
I / /
I ---L _______________ _ _,,, .. /· ...... ,,,
_ .. ~~·---~ _____________________________ .... ---------~=
-• __ :~-'.?::.\,;.~\r.\:"i'\<~: f(i-~?. '.::~\\//,/.~•.:< ·\:'<.\ .-,/ rv:.\?,\-\.:f::,~;f\\, ~:·:<x ·: \< :· -\· ,: .\-:; .. '::?,,~-.~,.. ',/<:"_>· :>,f. i --, -;-(;)j/;/:·t< /" ·
I
I
I
I
I
TOWN
C~ARCOAL COLO!'<
CONCi.ETE
SIDEWALK EA &IDE
CF ADA FATH
f''''"'"'''''''"""'''··.-m,.•,m.-.-•
t
I l _______ ,
,_
GARDEN ROAD
/ ,.,,..__.,.-~·,.,,,-_,.-,' V
./
,,
/
,., . .--
' ' ' ' ' '
' ' '
' ' \
' ' '
' ' ' '
' ' ' '
.-------------------------1 WATER:
SITE KEYNOTES GAS & ELECTRIC:
CARL56AD MUNICIPAL WATEFt Dl5TFtlCT
1------------------------1 STORM DRAIN: SCHOOLS:
5AN DIEOO c.AS ' ELECTFtlC
CITY OF CARL56AD
CAFi!-56AD UNIFlcD SCHOOL Dl&TRICT
56C C0!'11UNICATIONS INC.
CARL56AD FIFtE DEFAFtTHENT 0
0
SDG&E EASEMENT FOR GAS PIPE LINES AND INCIDENT AL PURPOSES
A 10' EASEMENT FOR GENERAL UTILITY ANO ACCESS ANO
INCIDENT AL PURPOSES.
ii\ A 50' EASEMENT FOR LANDSCAPE MAINTANENCE AND INCIDENT AL
\:_,/ PURPOSES.
0 A 10' EASEMENT FOR LANDSCAPE MAINT ANENCE AND INCIDENTAL
PURPOSES.
\ ' ' ' ' \
' ' ' ' \ ' ' \
' ' \ ' ' ' ' \
TELEPHONE:
FIRE PROTECTION:
PROJECT PLANNING DATA
PPLICANT / OWNER:
ARCHITECT:
APPLICATIONS SUBMITTED:
6RESSI FtANCH MEDICAL PLAZA, LLC
C/0 UR6AN WE:&T
!136 E, eANT A ANA 60ULEVAFtD
5ANTA ANA, CA 927,Z,f
Fi-!ONE. 714!>67,S26rD FAX. 1I4.242.'~<D,Z,1
CONTACT, KIM HUTCHINGS
5111TH CONSUL TINa ARCHITECTS
I222,Z, l=L CAMINO REAL, 5UITE 21U)
5AN DIEOO, CA S2I3<D (/3!:>6) 7~-4771
CONTACT, PETE 6US5ETT
G,PA ' SPF,
MF FUD ,
SUP ,
CT
$ WW 07-07
,z,1--03
178(F)
,Z,1-<D4
<D1-<DI
<D1-<D4
PROJECT ADDRESS: '-'221 -METROPOLITAN STl'<El=T
A.P.N,: 2I3-lbe>-e>I
\ ' \ EXISTING ZONE: F-C !PLANNED COHHUNIT'!')
' '
' \
' \ \
\ \
\ ,._\ " CIJ \\ ' \ .
I ' \ z
Ci( ,._ i \
I ' ' -..,
0
Q.
0
IC ,._
IU
~ /
l-..
l
/
I
' \
' \ \ ' \
\ \
\ \
\
\
\ \ \ \ \
\
\
\ \
\
\
\
\
_\_ --
--=-~=-=-r~=-E -=--cP;A=--. =-.,N'-----~. n ~
u ·' -------·' e-cALE1 1• ■ 301-t!J•
PROPOSED ZONE: F-C
EXISTING GENERAL PLAN: F-I <PLANNED INDUSTFtlALJ
PROPOSED GENERAL PLAN: O /OFFICE>
EXISTING LAND USE: VACANT FFtE-c.RADED
PROPOSED LAND USE: MEDICAL OFFICE
BUILDING OCCUPANCY: '6'
BUILDING CONSTRUCTION: T'!'FE, v I-HR i&F'RINKLEFtDJ
LEGAL DESCRIPTION:
LOT I OF CARL56AD TRACT No, S9-e>3, IN THE CITY OF CAFtLS6AD, COUNT'!' OF 5AN
DIEOO, f>TATE OF CALIFORNIA, ACCOFtDINa TO THE HAP ~EREOF No, I496/ZI, FILED
IN THE OFFICI! OF THE COUNT'!' l'<ECOFtDEFt OF SAN DIEOO COUNT'!'.
PROJECT SITE DATA
GROSS LOT AREA: 84,721 •.f. <1..94 acrCO&)
NUMBER OF LOTS PROPOSED
BUILDING AREA:
FIRE>T FLOOR AREA,
SECOND FLOOFI Ai.EA,
TOTAL
FLOOR AREA RA TIO (F.A.R.J
LOT COVERAGE:
TOT AL LANDSCAPE AREA:
I~16<D &F,
24!r.
1,%
27,118 5QFT
PARKING REQUIRED: (!S/1000 S.F.I ss
(;12%)
STANDAFtD STALLS (/3'-I>' X 2rZ>'>. (~~ &
ca1FACT STALLS(&' X l&'J UN.O, "4i''-fillif
ADA 5TALL5, 4 /I van)
TOTAL PARKING, ~&
AD T: !:<Z)t1,z,;w; • "l8&
PATIO AREA:
REGll.Jli.ED EATING AREA t,;w; SF. PEI'
5,e><D(f) SF, CF 13UILDING Ai.EA>.
OUTDOOFt EATING Ai.EA f'FiOVIDED,
1,1136 &F.
1,1136 &F.
r----------------------------------------.------------------------r-------------------------lAREA OF SITE WHICH IS UNDEVELOPABLE PER ZONIING NOT AFFLICA6LE
.
M ,, ' J6'~!1)'• l ...
e,•-e,11 . -1,' ~·-~· .. ~ .s.i-a~· .
' . . ' .. • . * .. /S' . . . . . ; . . ' ...
rv rv1~ .
~ ..
..
-..
' ..
' ..
, ,
,-.. ' ~7 -' --7 ,..,--
: I ·• a: I I I
I Ii' ~ I ~ I Q Ii' I
I ' ~ I ~ I ' ~ I s: ' s: I ~ I l I ;., ~ I ~ ~ I I I I
I al I I al I L ___ _J L ___ _J :
'-'-:cl>'.:~ CURB.~
·1
b ' "J:
I
;., • ..
,. &ma, DECKJN<i II <>A F1<IM1'D
A>1D PAINTED TO MATCH flUII..DIN<i __
'
4' DEEi" VE"1', CANe
llOI-T ANCHOR HOI..! Dl<ILLEP IN CONCl<l=TE.
,
ruee &TEEi. JAMe Fie!< D11-
• 6IJ::l'G. OIL y --~
& Tl-. """"3LE JAME'
'
CONC.. ~P·uP TO
TGf' a CONC. CUl'S
PEI< P1..A'<
,
•
"' • !
~
;,-..
FIRE NOTES:
1. THE AREA AROUND THE 'DETECTOR CHECK VALVE ASSEMBLIES'
EXTENDING A MINIMUM OF 16 INCHES FROM THE OUTER EDGE OF THE
RISER SPOOLS AND COMPLETELY UNDER THIS APPLIANCE SHALL BE
COVERED WITH AT LEAST A THREE-INCH THICK PAD OF PORTLAND
CEMENT. THIS WILL NEGATE THE NEED TO LANDSCAPE THIS AREA.
2. THE AREA AROUND ALL FIRE HYDRANTS SHALL BE COVERED WITH A
MINIMUM OF THREE-INCH PAD OF PORTLAND CEMENT EXTENDING A
MINIMUM OF 36 INCHES OUTWARD FROM THE CENTER OF THE FIRE
HYDRANT.
LIGHTING NOTES:
PROJECT LEGEND
SITE ACCESSIBLE PATH OF TRAVEL:
[MIN. 4' WIDEI
FIRE HYDRANT [NEWI:
DETECTOR CHECK ASSEMBLY INEW]:
POST INDICATOR VALVE [NEWI:
SITE LIGHTING
EXISTING STREET LIGHT
ELECTRICAL TRANSFORMER PAD [NEWI:
ACCESSIBLE VAN PARKING SPACE:
[9'W x 18'0 W/ 8'W x 16'D AISLEI
[]-{] -a
j I
.i i , ' ,. ~
/ ji
.c /!
,// .,.•<·· ,~ ..
ORDINANCE SECTION 21.53,230
SIGNATURE BLOCK:
APPROVED -C ~ c;, "'--c:>7
PLANNING DATE
en I I
0
Q)
I I
■-
e>.=m=
;~~:,:,;;. ;,-nJi
""" ""\
... ,1, .. 1<""
fi,."<lt.,:R~~t
,¥1t:ccc».<.<.~
t"'""i "'''i««~'.i,
)
..c
I ' ■-E
Cl)
ill2005 Smith Con,ultin1 .'\r,;hihch
ca
&1 -a. -~ I"-·-(J)
"'C w
Cl) ~ :! z
.c <( co () ~ C :) ca ••• a: -!II ■■!II. ·-U)
U)
! m
Revision Dates
Resubmit 8/9 /07
Resubmit 8/2.7 fJ7
~Consistency
i..r'> Determination 0512 lft)9 ZS
Issue Dates
Planning
Design Development
Plan Check
Bid Set
Permit Set
Construction Set
Drawing Date
Check By
Drawn By
Scale
S{l.7/07
PB
I "=30'--0' • ,_... . ♦ -»_,j.i4:N .·•-'¥,
,•~-1ob.Numb9f',•f,£t, .:;,....· •· ,,
,.,., . , , ,, .. , ' •' /,. ,-· •'. ~ ,•
,..
, . .,.. ..., / , / ,·· .,.. .,. ,·· / ,,. ..... '-·
ALL OUTDOOR LIGHTING MUST COMPLY WITH CMC SECTION
21.34.090 (4), WHICH STATES "ALL USES SHALL BE OPERATED
SO AS NOT TO PRODUCE ... GLARE OR HIGH-INTENSITY
ILUMINATION WHICH IS PERCEPTIBLE WITHOUT INSTRUMENTS BY
THE AVERAGE PERSON WHILE ON OR BEYOND THE LOT
CONTAINING THE USE".
FIRE TRUCK TURING RADIUS: (42'
RAD. CITY OF CARLSBAD F.D.J t ---.. ... ·• 06267.S 111 . ··• ~ OR-IT FAQ! C/'1J 1'1..0CK
TO MATCH a<Jll..Di-ic;
TRASH ENCLOSURE PLAN / ELEVATION N,T,5, 1
STANDARD PARKING SPACE: [8.5'W x 20'0
W/ 2' OVERHANG-ALLOWED!
COMPACT PARKING SPACE: [8'W
x 15'D W/ NO OVERHANG]
TT
TT
t ,.~eet Number. ; ,_ .
-
-