HomeMy WebLinkAboutCDP 2019-0027; FLOWER FIELDS RESTROOM; Planning Commission1 \ \ \ \ \ \ \ \ \ \ ) I I I CARLSBAD PREMIUM OUTLETS \ ,,--~"'' RESTAURANT SITE PLAN Coastal Development Permit CDP 2019-0027 (DEV2019-0187) NEW RESTROOM BUILDING at THE FLOWER FIELDS i \ - CITY OF CARLSBAD PLANNING COMMISSION Case Narne:-f:1i,W61l ~!~L~S Jirs.~M- Case No.: CAP-:Z.olj-o CQ.. 7 Exhibit No.: 6, -~ Date: Cl Lis [20 RETAIL , I C 0 50' 150' 300' SCALE 1"=150' N EB PROJECT DESCRIPTION: THE ADDITION OF A Na'! 640 5.F., SIN<SLE STORY, DETACHED MEN'S RESTl'toOM BUILDIN6, INCLUDIN<S A UNISEX FAMILY ROOM. PROJECT INFORMATION: DATE OF PREPARATION: PROJECT NAME, APPLICATION TYPE, STREET ADDRESS: ASSESSOR'S PARCEL NUMBER, LOT ACREA6E, LE6AL DESCRIPTION, EXISTIN6 6ENERAL PLAN LAND USE DE516NATION, EXISTING, ZONIN6: TOTAL LOT BUILDIN6 COVERA6E, PROPOSED NEV"l BUILDIN6 FLOOR AREA, PERCENT OF SITE TO BE LANDSCAPED: NUMBER OF PARKIN6 SPACES REGUIRED, NOVEMBER 6, 201"! NEV"l Rf:STROOM BUILDIN<S AT THE FLOv-lER FIELDS COASTAL DEVELOPMENT PERMIT 5i04 PASEO DEL NORTE, CARI..SBAD, CA c:i2ooe, 211-02:t-21-oo LOT I OF CARI..SBAD TRACT "14-0"!, CARLSBAD RANCH UNIT I IN THE C.ITY OF CARLSBAD, COUNTY OF SAN DIE60, STATE OF CALIFORNIA, ACCOR.DIN<:; TO MAP NO. 1555i. 05 -OPEN SPACE 05 -OPEN SPACE 0.5% 640 S.F. EXISTING, = 96. (NO NET CHAN6E PROPOSED) _NlJ_MBER __ o_F_P_A_R_K_IN_cS>_S_P_A_C_ES_P_R_O_V_I_D_E_D_, ________ __._i"!_.,l--'(=E>':15TIN6), NO CHAN6E PROPOSED BY PROJECT SQUARE FOOTA6E OF REQUIRED EMPLOYEE EATIN6 AREAS, NIA SQUARE FOOTA6E OF OPEN SPACE OR RECREATIONAL SPACE, NIA AREA OF THE SITE v-lHICH 15 UNDEVELOPABLE PER ZONIN6 NIA ORDINANCE SEC. 21.55.250, CUBIC FOOTA6E OF STORA6E SPACE, AVERA6E DAILY TRAFFIC 6ENERATED BY PROJECT: SEv-lER DISTRICT: MTER DISTRICT: SCHOOL DISTRICT: PROPOSED v-lA TER DEMAND (POTABLE), PROPOSED SEv-lER 6ENERA TION, CLIMATE ACTION PLAN (CAP) COMPLIANCE, GRADING QUANTITIES: ClJT, 125 C.Y. FILL, 0 C.Y. NET, 125 C.Y. CUT (DISPOSE ON SITE). BUILDING CODE DATA: SIN6LE-STORY OCCUPANCY CLASSIFICATION, B TYPE OF CONSTRUCTION, YB BUILDIN6 HEl6HT, 15'-6" SPRINKLERED, NO SITE 5i04 PASEO DEL NORTE CARLSBAD, CA "12008 VICINITY MAP NOT TO SC.ALE N EB NONE PROPOSED NIA CITY OF CARI..SBAD CARLSBAD MUNICIPAL MTER DISTRICT CARLSSAD UNIFIED SCHOOL DISTRICT MA.l:GMlJM PEAK FLOV"l, se, 6.P.M. AVr.:i;:A~E FLOV"l: SO 6.P.M. ON OPEN DAYS (i DAYS PER v-lEEK, MAR I -MAY 10). MAXIMUM DAILY PEAK FLOV"l, "!"10 6.P.D. AVEP-AISE DAILY FLOV"l, 500 6.P.D. ON OPEN DAYS (i DAYS PER v-lEEK, MAR I -MAY 10). NIA, PROJECT UNDER 1poo 5.F. OWNER & APPLICANT: ca RANCH ENTERPRISES, A CALIFORNIA CORPORATION CONTACT, MR. CHRISTOPHER C. CALKINS i220 AYENIDA ENCINAS 1>204 CARLSBAD, CA "12011 TEL.."'PHONE, (i60) 451-5600 CONSULTANTS: ARCHITECT: 4 DE5l6N ARCHITECTURE 4 PLANNING, KENNITH L. CHRISS, AIA, NCARB 15"!90 MISTY OAK DRIVE, VALLEY CENTER, CA "12028 TELEPHONE, (i 60) "I 19-5556 LANDSCAPE ARCHITECT: R. v-l. APEL LANDSCAPE ARCHITECTS, INC. CONTACT: RICHARD APEL 5il-B HY6EIA AVENUE, LEUCADIA, CA. "12024 TELEPHONE, (i60) "149-0i60 CIViL EN<SINEER, dk 6REENE CONSUL TING, INC. CONTACT, KRISTIN L. 61<.EENE, PE, MBA P.O. BOX 149, BONSALL, CA "12009 TEl..,EPHONE, (i60) 910-"!408 SHEET INDEX: 01 COVER SHEET 4 SITE PLAN 02 ENLAR6ED PARTIAL SITE PLAN 09 SITE PLAN DETAIL A-I FLOOR PLAN$ INTERIOR ELEVATIONS A-2 EXTERIOR ELEVATIONS A-5 ROOF PLAN $ DETAILS A-4 BUILDING, SECTIONS D-1 SITE ACCESSI.BILITY DETAILS D-2 BUILDIN6 ACCESSIBILITY DETAILS D-9 MISCELLANEOUS ARCHITECTURAL DETAIL5 C-1 CONCEPTUAL 6RADIN6 PLAN C-2 L-1 L-2 CONCEPTUAL v-lET UTILITY PLAN CONCEPTUAL LANDSCAPE PLAN CONCEPTUAL MTER CONSERVATION PLAN CDP 2019-0027 4 DE~IGN architecture• planning Kennith L. Chriss A.I.A. C 13351 * Exp. 12/31/1 '-1/; 1';-r or c ~'l r-wApel landscape architects inc r-- N 0 0 I a, ..- 0 N CL 0 u -E '-Q) CL -C Q) E Q_ 0 Q) > Q) 0 Cl) -Cl) Cl) 0 u 571-B Hygeia Avenue Leucadia, CA 92024 (760) 943-0760 rwapel2@cox.net CA license #2825 gJ3o"'120 Rer,eWQl DClte * CA 1.- (9 z en -0 0 _J _J w -::::, -LL cc 0::: ~ w 0 s 0 0 0::: _J I-LL en w w 0::: I I-s +J w ro z Project # Drawn by Scale As shown Date November 06, 2019 co 0 0 N a, <( u "O Cl) .0 Cl) -;:: Cl) u Q) t:: 0 z Q) 0 0 Q) Cl) Cl) CL -.:I"" 0 r-- LC) COVERSHEET & SITE PLAN SHEET 01 I I I ! -----------------: - 85.B 84.3 \ \ \ \ N EB 0 5' 10' 20' 1 ENLARGED PARTIAL SITE PLAN SCALE 1"=10' SITE PLAN KEY NOTES: IT] FIELD VERIFY AND INSTALL IF NECESSARY PROPERTY ENTRANCE ACCE55 SIGNS PER DETAIL A/D-1. 2. EXISTING ACCESSIBLE PATH OF TRAVEL 6ETYIIEEN PROPOSED NEYII BUILDING AND THE PUBLIC YIIAY. THE PATH OF TRAVEL SHALL BE 4'-0" YIIIDE MINIMUM AND HAVE A MAXIMUM 1,20 (5%) SLOPE IN THE DIRECTION OF TRAVEL AND LESS THAN 2% CROSS SLOPE. B. INSTALL NEYII TRUNCATED DOMES PER DETAIL H/D-I YIIHERE ACCESSIBLE PATH ABUTS AUTOMOBILE DRIVEYIIAYS. 4. PAINT AN AC-CESSIBLE PATH OF TRAVEL YIIHERE YIIALK5 C-R055 AUTOMOBILE DRIVE YIIAYS AS INDIC.ATED AND CONSTRUCT PER DETAIL L/D-1. 5. 8 EXISTING HANDI.CAPPED PARKING STALLS. VERIFY CONSTRUCTION IN. THE FIELD. REFER TO DETAIL C/D-1 FOR REQUIRED DESl6'N AND CONSTRUCTION. 6. INSTALL A NEYII TACTILE ENTRANCE SIGN PER DETAIL t/D-1. 1. INSTALL AN ACCESSIBLE RESTROOM 5I6'N PER DETAIL F/D-1. 8. EXISTING, PROPERTY SERVICE ADDRESS ON FENCE, REFER TO DETAIL K/D-B. '1. INSTALL A NEYII ADDRESS Sl6'N '5104' ON THE EXISTING, SIGN BOARD PER DETAIL K/D-B. ADDRESS NUMBERS SHALL COMPLY YIIITH TABLE A IN CMC SECTION 21.41.040. NOTE: A, PROVIDE DRAINA6'E SLOPE OF A MIN. 1/4" PER FOOT (2%) AYIIAY FROM THE BUILDING ON ALL 5IDE5. B. STANDARD YIIET AND DRY UNDERGROUND UTILITY TRENCHING, 15 INDICATED BY DETAIL N/D-B. C. INSTALL NEYII UNDERGROUND ELECTRICAL SERVICE FROM THE EXl5TIN6' MAIN SERVICE PANEL TO THE NEV>! BUILDING,. D. REFER TO CONCEPTUAL LANDSCAPE PLAN. THE IRRl6'ATION SYSTEM SHALL BE ADJUSTED PER THE LANDSCAPE ARCHITECT'S DI REC.Tl ON. E. ACCESSIBLE YIIALKS V>IITH CONTINUOUS 6'RADIENTS ARE TO BE PROVIDED YIIITH LEVEL AREAS EQUAL TO OR GREATER THAN 5'-0" AT 400 FT. INTERVALS MAX. (NOTE THIS CONDITION DOES NOT EXIST ON THIS SITE.) F. STORM YIIATER POLLUTION PREVENTION, FOR PROJECTS V>IHICH DISTURB LESS THAN ONE AC.RE OF LAND AND ARE NOT PART OF A LAR&ER COMMON PLAN OF DEVELOPMENT OR SALE SHALL PREVENT THE POLLUTION OF STORM YIIATER RUNOFF FROM THE CONSTRUCTION ACTIVITIES THROUGH ONE OR MORE OF THE FOLLOYIIING MEASURES, a) STORM YIIATER POLLUTION PREVENTION. (ONE ACRE OR MORE) COMPLIANCE YIIITH NPDE5 15 REQUIRED. SEE CGC 5.106.2 FOR C.OMPLIANC.E REQUIREMENTS. THE FLOYIIER FIELDS PALOMAR AIRPORT ROAD ~ VICINITY MAP NORTH SCALE: NONE s::sJZ7 AREA SHOV'lN CDP 2019-0027 4 DE~IGN architecture ■ planning Kennith L. Chriss A.I.A. C 13351 Exp. 12/31/19 r-wApel landscape architects inc I'-- N 0 0 I 0) ..... 0 N a.. 0 0 -E '-Q). a.. -C: Q) E C. 0 Q) > Q) 0 ro -C/) ro 0 0 571-B Hygeia Avenue Leucadia, CA 92024 (760) 943-0760 rwapel2@cox.net CA license #2825 (9 z Cl) -0 0 .....J .....J -w :::, -LL co 0::: ~ w 0 s 0 0 0::: .....J I-LL Cl) w w 0::: I I-s +-I w ro z Project # Drawn by Scale As shown Date November 06, 2019 00 0 0 N 0) <( 0 "O ro ..c C/) '-ro 0 Q) t:'. 0 z Q) 0 0 Q) C/) ro a.. """ 0 I'-- I!) ENLARGED PARTIAL SITE PLAN SHEET 02 ~ ~ 0 = ~ "' = = "' = < ~ ~ .., ~ = ~ Se u ~ C, El Sa' ~ 0 ""' F < ~ '3 F = < ~ 0 = < ~ = ~ = = 0 u = I=' ~ ~ = 0 i"= "" = = a= < = = = i"= = = < = 0 !c;' "" = 0 ~ "' ~ i"= ~ 0 ~ = = E3 cc F = ~ '2 ~ u "' 0 = ~ = ~ cc 8 ~ = ~ i"= = 0 ~ = = = e = ~ = ;g = ~ ~ u 5 = ~ = ~ 0 ~ = ~ "' = ~ = ea = < "' = 0 F < "" = e ea = = < = = "' < = = ~ 0 aa = = < ~ ~ .., = = ea u "' Se u = < C, vi ~ = -t'5 ;,:: ffi ~ = = ~ ~ i"= ~ ~ = = = F < ~ ~ ;;! 1':! = = < '2 l3 = 0 u = = u5 ~ = "' = ~ "' Se u = < 8 = 5 0 = ~ = = F < "' = 0 ~ 1 aa ~ i"= = = < = z a. < = = "' i"= "' / \ \ \ ' ' I I I I I I I ) 00 -., \ EX[STIN6 PARKIN6 \ \ + 86.5 I I \ I REMOVE EXISTIN6 MAINTENANCE ACCESS PATHJl'IA'T'. \\ j \ ) j N ~ 5' l"!IDE MAINTENANCE L ACCESS PATHJl'IA"(_ PERMEABLE DECOMPOSED 6RANITE _L PAVIN6. NOT A PUBLIC VISITOR I 87.~ESS. I SITE PLAN DETAIL _I_ : 88.5 \ \ EXISTIN6 DRIVE AISLE (A.G. PAVEMENT) \ ~ Vi\\ i ' \ -,-PQ n \ \ I C;.:J.L \ \ I I I I I o SCALE 1"=10' ( \ \ \ 5' 10' 20' \ \ \ N EB KEY: NEV"\ 2x4 V"\OOD BENDER BOARD ED5E. NEV"\ PERMEABLE DEC-OMPO5ED cSRANITE PAVINcS. NEV"\ i"lROU5HT IRON 5ATE (OR RELOC-ATE EXl5TIN5). EXl5TIN5 6' Hl5H C-HAIN LINK FENC-E (TO REMAIN). EXISTING, PLANTING, TO REMAIN. REFER TO C-ONC-EPTUAL LAND5C-APE PLAN SHEET L-1 FOR MORE INFORMATION. NEV"\ PLANTIN5. REFER TO C-ONC-EPTUAL LANDSC-APE PLAN 5HEET L-1 FOR MORE INFORMATION. CDP 2019-0027 4 DE~IGN architecture ■ planning Kennith L. Chriss A.I.A. r-wApel landscape architects inc t--- N 0 0 I 0) ~ 0 N 0.... 0 0 -E '-(]) 0.... -C (]) E c.. 0 (]) > (]) 0 ro .... en ro 0 0 571-B Hygeia Avenue Leucadia, CA 92024 (760) 943-0760 rwapel2@cox.net CA license #2825 (9 z Cl) -0 0 _J _J -UJ ::::> -LL CJ a::: ~ UJ 0 s 0 0 a::: _J I-LL Cl) UJ UJ a::: I I-s ~ UJ co z Project # Drawn by Scale As shown Date November 06, 2019 co 0 0 N 0) <( 0 "t:l ro ..c en ;:: ro 0 (]) t 0 z (]) 0 0 (]) en ro 0.... "V 0 t--- I!) SITE PLAN DETAIL SHEET 03 44'-8" -,f-----------"rl------+---------~ 1------+----+------+-----+t----------f- 8'-0" lb.--.... 60' C '° 'I- I I ---- C N I 0 : • d) bO" I 'I- I '1" U) I C -r I 15 IJ" U) C C) I -rn 61" / 60" MIN. r,l------:----t1, - () I d) 1 2 LEGEND: 'i/////,/; SINGLE OCCUPANCY FAMILY RESTROOM ACCESSIBILITY SPACES 8x8xlb C.MU Y'llTH SPLIT FACE FOUR FLUTE AC.GENT UNITS, LAID IN R.UNNINcS BOND, MATCH EXISTINcS 2xb Y'IOOD FR.AME INTERIOR i"IALL, NON-RATED, NON-6EARIN6 SEE BUILDIN6 SECTIONS FLOOR PLAN SC.ALE: 1/4"= I '-0" b40 SQ. FT. ___ ___, 4 A A-4 INTERIOR ELEVATION KEY FLOOR DRAIN. REFER TO THE FLUMBIN6 DR.AY'llNcSS p,-.,--.......,,-'1-...,.-~-.~--c--'-j ---------, i 1---- 1""'"1~==========~ ' J ! ! ELEVATION 1 ELEVATION 2 @}- ,OJ \, ~ {27-I/ V / V ~v I\, I~ ~ ~ 1 ~ () i = i== -.,_ e= 1r - "" • . I / -I / . I I lfl ,-~ " . I / ~ ,~ "-.. _/ '-./ '-__,, '-./ ' , • • • ,-12 1-8 11 -• () •• ,2'-6" " ELEVATION 5 ,# lfl i ' TYP. · I I ' TYP.' -- -N INTERIOR ELEVATIONS SC.ALE, B/8"=1'-0" 3b'-8 30'-0" 15'-4" 0 ( 12'-6" 2'-10" I 0 2-2814 0 I I 2-2814 10'-IO'' 5'-4" B A-4 I/ 8" FER FOOT SLOPE IN CONCRETE FLOOR SLAB, REFER TO THE STRUCTURAL AND FLUMBINcS DRAY'llNcSS. REQUIRED AC.C.ESSIBLE FLOOR SFAC.E ' g II-'-! --,-I ,, . ___ ;i~---11,----"sc---, lf-·r-'--1 I I I ELEVATION 3 • I ,, ' □ DS 8 C C) \\) - I -I -C) r 'I-I -rn GALVANIZED SHEET METAL DOY'INSFOUT, REFER TO DETAIL A/D-3 FOR STANDARD APPLICATION AND THE ROOF FLAN AND EXTERIOR ELEVATIONS FOR SPECIFIC. AFFLIC.ATIONS I '"'""""~-~~....,...,,f..., ELEVATION 4 REFER.ENGE NORTH INTERIOR ELEVATION NOTES: I 8 [J] l"lALL HUNG> VIIATER CLOSET REFER TO DETAIL 0/D-2 AND 5RA6 BARS, REFER TO DETAILS E, F,5, H/D-2. i I I ' I I i "° ,/ 3 v , ~ , -- () i - d) • • 2. OVIINER TO SELECT PLASTIC LAMINATE PANELING> OVER 5YP5UM BOARD . S. CONCRETE CUR.El. 4. 24"X50" OJIIINER SELECT MIRROR. 5. VIIALL HUNG> LAVATORY, TYPICAL, REFER TO DETAILA/D-2 . 6. EXPOSED CONCRETE BLOCK. REFER TO 6UILDIN5 MATERIALS SECTION 04.0. FLOOR PLAN NOTES: [J] DASHED LINE INDICATES LOCATION OF ROOF OVERHAN5, REFER TO THE ROOF PLAN. 2. 2-2'-8" X l'-4" VINYL AVIININ5 VIIINDOVll5, REFER TO DETAIL A, 6, C/D-S. S. I 5/4" X S'-0" X 6'-8" SOLID CORE FULL FLUSH METAL DOOR VIIITH LEVER TYPE HANDLES BOTH 5IDE5 OF DOOR AND SELF-CL051N5 HIN5E5 AND DEAD BOLT SECURITY LOCK. OVIINER TO SELECT HARDVIIARE STYLE, COLOR, FINISH AND MANUFACTURER. REFER TO I, J/D-2 AND E, 4. 5. 6. F, 5/D-5. FOR ACCE5516LE 515NA5E REFER TO DETAIL D/D-2. 4'-0" X 6'-8" POVIIDER COATED IRON 5ATE. OVIINER TO SELECT COLOR. LEVER TYPE HANDLE TO BE USED BOTH 51DE5 OF 5ATE, REFER TO DETAIL L, 0, P/D-5. 5ATE HIN5E5 TO BE PER DETAIL H/D-05. 5ATE APPEARANCE TO ElE PER DETAIL 1/D-S. ACCE55I6LE 5IG>NA5E, REFER TO DETAIL D/D-02 AND THE EXTERIOR ELEVATIONS .. VIIALL HUN5 LAVATORY 51NK5 (4), REFER TO DETAIL A/D-S AND THE INTERIOR ELEVATIONS. FLOOR MOUNTED METAL TOILET '· PARTITIONS, REFER TO THE INTERIOR ELEVATIONS. 5RA6 ElAR.5 AT VIIA TER CLOSET, REFER TO 8 -DETAIL E, F, 5, L, H/D-2. 'I. VIIALL HUN5 VIIATER CLOSET VIIITH FLUSH VALVE HARDVIIARE, REFER TO THE PLUMBIN5 DRAVIIIN55, DETAIL 0/D-2 AND THE ElUILDING> r-1ATERIAL5 SECTION 22.1. 10. AMBULATORY VIIATER CLOSET COMPARTr-1ENT, REFER TO DETAILS K, L/D-2. H. ACCESSIBLE URINAL, REFER TO DETAIL M/D-2. 12. VIIALL MOUNTED URINAL SCREENS, REFER TO THE INTERIOR ELEVATIONS, PLUMBING> DRAVIIIN55 AND 6UILDIN5 MATERIAL SPECIFICATIONS SECTIONS 22.1. IS. 5'-0" X 6'-8" SOLID CORE FULL FLUSH METAL DOOR VIIITH LEVER HANDLE HARDVIIARE PER DETAIL J/D-2. 5EC.URITY LOCK TO BE A DEAD BOLT. OVIINER TO SELECT STYLE, FINISH, C-OLOR AND MANUFACTURER. REFER TO DETAILS H, I. J/D-5. 14. NEVIi VIIATER HEATER, REFER TO DETAIL M/D-S THE PLUMBING> DRAVIIIN5S AND ElUILDIN5 MATERIAL SPECIFICATION SECTION 22.1. 15. INSTALL A FOLDING> CHAN51N5 TAElLE PER MANUFACTURERS RECOMMENDATIONS AND DETAIL N/D-2. 16. ROOF DRAIN DOVIINSPOUT, RUN BELOVII 5RADE AND DAY-Ll5HT INTO THE EXl.5TIN5 CONCRETE DRAINA5E SVIIALE, REFER TO THE ROOF PLAN AND DETAIL B/A-5. ROOF DRAIN DOJIIIN5POUT J/IIITH CONCRETE Ii. SPLASH BLOCK AT 5RADE. REFER TO DETAILS C, D/A-5. TOILET PARTITION DOOR TO BE 2'-10" MIN. 18. CLEAR SPACE VIIHEN OPEN, REFER TO THE INTERIOR ELEVATIONS. THE INTERIOR SIDE OF THE VIIOOD FRAME I<!. VIIALL OF THE PIPE CHASE / CLOSET 15 TO BE OPEN FRAMING> FOR ACCESS TO THE PLUMBIN5. OY"INER SELECT TOILET PAPER DISPENSERS, 20.CONTRACTOR. TO INSTALL. REFER TO DETAIL H/D-2. ElATH EXHAUST FAN AT MEN'S ROOM TO BE 21. DELTA PRO 200 Y<IITH 200 CFM, 1.0 SONES AND 6' DUCT. BATH EXHAUST FAN AT FAMILY ROOM TO BE DEL TA ELECTRONICS 56R80, 120 CFM, 0.8 SONES Y<IITH A 4" DUCT. BOTH FANS USE 120V POVIIER Y<IITH A MOTION DETECTOR SVIIITCH. REFER TO DETAIL GID-S FOR V.T.R. GENERAL NOTES: A. ALL NON-PREFINISHED SURFACES TO BE PAINTED AS PER THE ROOM FINISH SCHEDULE UNLESS NOTED OTHERY-115E. 6. REFER TO 5N-2 FOR THE FINISH SCHEDULE. C. CONTRACTOR. TO SUBMIT SHOP DRAVIIIN55 TO THE OVIINER FOR REVIEVII AND APPROVAL OF THE TOILET PARTITIONS. PARTITIONS TO BE POJ/IIDER COATED. D. OJIIINER TO SELECT AND THE CONTRACTOR 15 TO INSTALL COAT HOOKS ON THE TOILET PARTITION DOORS. HEIG>HT TO BE 40" MIN. AND 48" MAX. FROM THE FINISHED FLOOR. E. THE CONTRACTOR SHALL PROVIDE SOLID BLOCKING, IN THE CEILING, TO SUPPORT THE TOILET PARTITIONS. 5'-0" l""--·r··•&.--,r·-··E======="'=a-!F""~-r,.,,...,-.~:•~1=""=1==·~.Jc=.=1r· i ' ii i. FOLDING CHANGIN5 TAElLE REFER TO DETAIL N/D-2. 8. METAL DOOR, REFER TO THE FLOOR PLAN. 'I. METAL SECURITY 5ATE, REFER TO THE FLOOR PLAN. 10. VINYL AJ/IININ5 VIIINDOJ/115, REFER TO THE FLOOR PLAN. II. TOILET PARTITIONS, SEE THE FLOOR PLAN AND 5ENERAL NOTE C. 12. SCREEN J/IIALL, REFER TO PONY VIIALL AT C/A4. CDP 2019-0027 4 DE~IGN architecture ■ planning Kennith L. Chriss A.I.A. C 13351 * Exp. 12/31/1 * r-wApel Jar..Jsw~ an:;J1itnts t- N 0 0 I CJ) ,..... 0 N 0.. 0 u -E !,.... (I) 0.. -C Q) E D.. 0 Q) ~ 0 ro -Cl) ro 0 u inc 571-B Hygeia Avenue Leucadia, CA 92024 (760) 943-0760 rwapet2@cox.net CA ttcense #2825 (9 z Cl) -o 0 _J :::::! w ::::, -CC LL ~ 0::: ow os 0::: 0 I-_J Cl) LL ww 0::: I $~ w ro z Project # Drawn by Scale As shown Date November 06, 2019 co 0 0 N CJ) <( u "O Cll ..a Cl) '-Cll u Q) t: 0 z Q) 0 0 Q) Cl) Cll 0.. "St' 0 ,-.... I.!) FLOOR PLAN & INTERIOR ELEVATIONS SHEET A-1 ~ = = = ~ "' = "' = = < ~ ~ "" w = ~ w ~ S" u = < = §il w = -~ = = = ,= < ~ cs II,. II,. ,= = < ~ / C, '\ .. ,, A "111.. = :', ~ = w = = = u % ~ ~ ~ ~ = = ;,a "" '" = "" < = = "' ;,a = = < = = ,= < :. = E "' w ;,a ~ = w = = d w c:: ,= z w 9 ,A-4 ' A-4' r .. 8 4 ~ 712 ' ' -II II II I II II II 11 / II II II II II 10 t= I'-----_ 10 I( 11 11 II : I 'I \I ~ 11 '>.c ,, !i :I 11 s ::=c----I -,.._ Yi. ,, II :I /I 11 ,I i ,, -I I -~ I I ,, Ir I 'I I ,...__ :1 [I I ,, 1, -l---I I I I -~ I Ii 11 11 ii ,j "I ..--i I I I -~ I ii ,I n: I I I ,, I I I ,, I I I I I ~ I I I I ,._,, I I I I I "' I I ] I ~ 111 1111 11111 I fl 1111 ' 11111 111 II I 11111 II 11111 1111 111 .I. tffiJI 11 I 5 s -I I I I !L t-I I I I I I I I I I I I I I I ~ .... ,I I I ~ I I I I I I I I I I I 1 I / I I /I I I I I I I I I I I I I r--' ~ = I I C) I I I I I I I I I I / I I .... I I -I I I I I I I I I I I I I I I I 2 ~ t-I I I I I I I I I I II I I I -------t-I I • I I I I I I I I I I I I I I ~ u a-= ~ 8 c:: cs w ~ = -~ EAST ELEVATION 6 NORTH ELEVATION w ;,a = = w = = e = w = ;a; ~ .L. ~ ~ /A\ 8 '-.A-4) / "I~ = ~ w u ,SC = tjj ~ 0 ~ = ' I l,,-~ 10 II I II 11 II II \: JJ II II II II II II II I II I II I II 11 , II II II II I II II II I II II ' II " II !I \ 11 I, 'I Ii ii I' II II I! I \I !I ll 11 Ii ii ii I ,, r: II 11 1! ,I ,: ,I ,, w ,. = "' = I I I I I \I I I I t r I I I I I I I\ I I I I I I I / I I I I I I I I I \ I I I I I I I I I I I I I I I \I I I I I I I I I I "' :', "' = = ,= < ,. e "' I I I I l~I I I I I /I I I I I I -I I I I I I I I I I I I I I I I I I I I I I I I 1111 111 1111 llltl UI 111111 Ill 11111 1111 11111 1111 11111 Ill 11111111111111 11111 1111 II 1111 Ill I I II I I UII 1111 111111 I I I I I I I I I I I t I I I I I I I I I I I I I I I I I I I I I I I I I I I I I = :', = I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I F I I I I I f I I I I I I I I I I I I I I I I I I I I = ~ = = I I I I I I I l I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I = ~ I I I I. I I I I I I I I I I I I I I r I I I I I I r I I I I I I I I I I I I I I I I I I I I I I ' I I I I I I I I I I 0 = z = < ~ ~ .., WEST ELEVATION w = "' u ~ "" = < ;,; "' w = -ls ;,:: = w ~ = = = w 1 ;,a w ~ ~ EXTERIOR ELEVATIONS SCALE: 1/4"= I '-0" = = ,= g = = ;;a ~ = = < ~ ~ ~ w u = 8 = = vl w = ~ < = ~ w t= = "' = < 13 = 5 = = ~ = = ,= < "" = E "' w ;,a = = < = = "" < = = ~ J B ... \;,,.-4,,' .,,, II II II II II 'I I II ' ! : 11 I 11 ,, 1! II l, I I I I I 11111 I 1111 1111 "' I 1111 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I s I Gl-~ s d ~ IS'-0" II 111/ ~ 'r BUILDING H II II II II II II II II II II II 1, EIGHT EXTERIOR ELEVATION NOTES: I! II I 11 I II A :, I I, ! I II I I I 1, 11 I _,.. I II I I I...,.,-I ! I : I I I I I I I I I I I I I I I I I 111 11111 111 1111 '1111 1111 I 111 111 11111 1111 1111 I I] ,--- I I I I I I I I I I I I I I I ~ I I I I I I I I I I , I I I I I I l / l I I I I I I I I I 11 I ! I I I I I/ I I I I I I I I I / I I ! I ~ ~ 4 ~/ C, ""A-4 ~ sf2-" ~ ~ "" ~12 --,.._ ~ -, I f.-'--I -----~ ,~ I I r--- I I ~ ~ I I I I I I I I I I ' I I I I I I I I 1111 I ti 11111 1111 11 11 I 1111 111 11111 , 1111 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I SOUTH ELEVATION Ii /./v ~ l I I I_ I I I 1111 I I I J-_ 8'-1" 'r CEILING HEI GHT I [iJ 8X8Xlb CONCRETE MASONRY UNITS l"llTH SPLIT FACE POUR FLUTE ACCENT, LAID IN RUNNING BOND. 2. FINISHED GRADE, SLOPE A MINIMUM OF 1/4"/FT. N"iAY FROM THE STRUCTURE. S. 5ALYANIZED SHEET METAL GUTTER AND DOl"lNSPOUT, REFER TO THE ROOF PLAN. I 'I I I I /70-0 I I 4. GALVANIZED SHEET METAL 5ASLE VENTS, REFER TO THE ROOF PLAN. S. METAL SECURITY CS.ATE, REFER TO THE FLOOR PLAN. 6 I I ~ 1111 I] I I I I I I I I 'f' FINISHED Fl OOR b. DOWNSPOUT UNDER5ROUND, REFER TO THE J-_ IS'-0" 'r BUILDING HEI.GHT 10 ~ 81-111 '-r CEILING HEI GHT .J._ 01-011 '-r FINISHED F LOOR FLOOR PLAN. 1. MET AL DOOR, REFER TO THE FLOOR FLAN. 8. CUPOLA, REFER TO THE ROOF FLAN AND DETAIL E/A-S. 'I. ACCESSIBLE RESTROOM SIGNS, REFER TO DETAILS F, G, K/D-1. 10. METAL ROOFING, REFER TO THE BUILDING SECTIONS AND THE ROOF PLAN. If. VINYL l"llNDOJ/'6, REFER TO THE FLOOR FLAN. CDP 2019-0027 4 DESIGN architecture ■ planning Kennith L. Chriss A.I.A. C 13351 * Exp. 12/31/19 * J>, ~ -,,,-/f" or c ~ \. \'i <;:i~ r-wApel r--. N 0 0 I (j) ~ 0 N Cl. 0 () -E ,._ Q) CL -C (I) E a. 0 Q) > (I) 0 ca -(/) ca 0 () inc 571-B Hygeia Avenue Leucadia, CA 92024 (760) 943-0760 rwapel2@cox.net CA license #2825 C) z en -0 0 _J _J -LU :::J -LL ca 0:: ~ LU 0 s 0 0 0:: _J I-LL en LU LU 0:: I I-s --1--1 LU ro z Project # Drawn by Scale As shown Date November 06, 2019 CX) 0 0 N (j) <( () "Cl ca ..0 (/) ..... ca () -Q) t 0 z Q) 0 0 (I) (/) ca Cl. ,;t 0 r--. I.O EXTERIOR ELEVATIONS SHEET A-2 NOTE: SUBMIT SAMPLE OF CONFIGURATION OF GUTTER AND DOVIINSPOUT TO ARCHITECT FOR APPROVAL PRIOR Tl INSTALLATION. A ROOF GUTTER AND DOWNSPOUT STANDARDS CONCRETE [!] 2. 9. 4. 5. b. 1. 8. Cf. 10. 11. 12. 19. HALF ROUND GUTTER , SLOPE I/8"/FT. U.N.O. ROUND FIFE 9 ELBOVIIS HALF ROUND OUTLET END CAPS CORNER MITRES ROOF-MOUNTED HANGER VIIRAP-AROUND HANGER LEADER HEAD DECORATIVE FIFE BAND LEAF STRAINERS RADIUS END C-AP ROUND CORRUGATED PIPE DOVIINSPOUT--, 4" DOWN SPOUT, SEE--._ ARCH. DRAWINGS FOR STYLE SPLASH BLOCK -~ 6" P.V.C. PIPE---.. EXTENSION 6" P. V.C. PIPE, MIN. 1 % SLOPE TO CIVIL DRAINAGE 6" P. V.C. ELBOW B DOWNSPOUT BELOW GRADE BOUNDARY NAIL 2-1/2" DIA. H·q/t..E.._.\---+....::2::4!:...." ____ f 2X BLOC.KING ASS EACH BLOC-K = DOUBLE MIN. TOP PLATE NOTE, -1/2" ROOF PLY'VIID 2X RAFTERS VENT BLOCK PROVIDES 14.1 SQUARE INC.HES N.F.V.A. G EAVE ATTIC VENT I2"xl2" CONG. AN.C1::IPR ELEVATION 2'-0" • f .. C) I -- • .. PLAN C DOWNSPOUT INTO SPLASH BLOCK 90# FELT UNDERLAYMENT PL YVIIOOD .--- SHEATHING H RIDGE VENT 2 11 ROUND HOLE FER AL TERNA TING RAFTER SPACE, REFER TO THE ROOF INSECT SC.REEN OVER OPENNG "-RAFTER RIDGE BOARD l'-6" 8'-0" s A A-4 1 ROOF PLAN SC.ALE, 1/4"= I '-0" PLYVIIOOD ROOF SNAP-SEAM PANEL --._ SO# FELT -------... RAKE PANEL 2XIO FASCIA \ D ROOF GABLE OVERHANG GALVANIZED LOUVE D VENT INSECT SC.REEN GABLE VENT ----C.MU VIIALL r---C.AULK VIIEATHERTIGHT '--GALVANIZED SHEET METAL TRIM ALL ROUND 44'-8" B A-4 METAL ROOFING------. SYSTEM PL YVIIOOD ~"" ROOF 2x 10 VIIOOD FASCIA C.MU VIIALL 36'-B" 42'-2" 24" E ROOF EAVF OVERHANG SNAP-SEAM METAL PANEL METAL GUTTER-, SUPPORTS GALVANIZED SHEET METAL-~ GUTTER 2X 10 FASCIA PLYVIIOOD SOFFIT SEE PLAN FOR OVERHANG EXTERIOR VIIALL J ROOF EAVE GUTTER !I ,, 1,Ds ,, l'-b" - 't I lf) ROOF PLAN NOTES: [Q 6-AL VANIZED SHEET MET AL ROOF 6-UTT'ER AND DOl"lN5FOUT, REFER TO DETAILS A, 6, J, C/A-9. 2. ROOF GABLE OVERHANG, REFER TO DETAIL D/A-9. 9. ROOF EAVE OVERHANG, REFER TO DETAIL E/A-5. 4. ROOF RIDGE DETAIL, REFER TO DETAIL F/A-9. S. EAVE VENT, 4 LOCATIONS, REFER TO DETAIL G/A-9. €>. RID<S-E VENT, REFER TO DETAIL H/A-B, A/A-B. i. GABLE VENT, REFER TO DETAIL I/A-5. e,_ STANDING SEAM METAL ROOF, REFER TO BUILDING MATERIAL SECTION Oih. '!. EXTERIOR. MASONRY l"lALL BELOl"l. REFER TO THE FLOOR PLAN. 10. ARR.Ol"lS INDICATE THE DIRECTION (l"llTH A -----"ls----1; SLOPE OF 1/8" PER FOOT) THAT THE GUTT'ER. PREFINISHED METAL: ROOFING PANEL 90# FEL UNDERLAYMENT FL YVIIOOT?.---"""-...J SHEATHING F ROOF RIDGE FLASHING COMPOUND YELLOW GLASS FABRIC 6" MIN. BASE PLY 30# FELT OVER PLYWOOD ROOF K VENT TH RU ROOF SHOULD SLOPE TO DRAIN. TYPICAL. II. VENTILATION HOLES IN ROOF DIAPHRAGM, REFER TO DETAIL H/A-9. ::2::2 REQUIRED. GENERAL NOTES: A. VENTS THRU ROOF PER DETAIL K/A-9 TYPICAL. REFERENCE NORTH r-PR'EFINSHED HIP COVER OFFSET "Z" CLOSURE TO PROVIDE VENT GAF INSECT SC.REEN EALANT RAFTER RIDGE BOARD PLUMBING VENT PIPE JACK FLANGE 4" MIN. ROOF AREAS: ROOF AREA 'A' 4'!.5 SG. FT. ROOF AREA '6' 251.8 SQ. FT. ROOF AREA 'C' 251.6 SQ. FT. ROOF AREA 'D' I58.i SQ. FT. ROOF AREA 'E' 158.1 SQ. FT. NOTE, CFC TABLE II05.B ALLOl"lS A 6-UTTER OF 4" TO SERVICE 120 SG. FT. CFC TABLE 1101.12 ALLOl"lS A 4" TO SERVICE 18,400 SG. FT. CFC TABLE 1101.8 ALLOl"lS A 4" TO SERVICE 1;5::20 SQ. FT. ALL OF THE GUTTERS, DRAINS, LEADERS, VERTICAL AND HORIZONTAL STORM l"lATER PIPING SHALL BE 4". ATTIC VENTILATION: ATTIC AREA, 600 SG. FT. X 144 = 86,400 SG. IN./ 900 = 288 SQ. IN. REQUIRED. VENTILATION PROVIDED, RID6E VENT, 4.'! SG. IN. PER VENT N.F.V.A X 22 = 101.8 SQ. IN. FREEZE BLOCK VENT, I4.iX4 SQ. IN. N.F.V.A. X 4 l"llTI+ 58.8 SQ. IN N.F.V.A. AT BLOCK PER DETAIL 6/A-9. GABLE VENT, 288 SG. IN. N.F.V.A. X 4 l"llTH 1,152 SQ. IN. PER DETAIL I/A-9. TOTAL AREA PROVIDED 1,518.6 SG. l'N. CDP 2019-0027 4 DESIGN architecture• planning Kennith L. Chriss A.I.A. C 13351 * Exp. 12/31/19 * 1/, ~ :.r-1' or c ~1__\'\'()~ . r-wApel Jandstape ardJJJerts inc I'- N 0 0 I 0) '<""" 0 N 0.. Cl 0 ..... E '-(I:) 0.. ..... C Q) E c.. 0 Q) > Q) Cl en ..... (/) en 0 0 571-B Hygeia Avenue Leucadia, CA 92024 (760) 943-0760 rwapel2@cox.net CA license #2825 C) z Cf) -0 0 ....J ....J -w ::::, -LL cc ct: ~ w 0 $ 0 0 ct: ....J r-LL Cf) w w ct: I r-$ +-' w co z Project # Drawn by Scale As shown Date November 06, 2019 CX) 0 0 N 0) <( 0 "O en ..0 (/) '-en 0 Q) t:: 0 z Q) Cl 0 Q) (/) en 0.. -.;f" 0 I'- I.!) ROOF PLAN & DETAILS SHEET A-3 = ~ "' 5= = = 0- "' ~ = z = :s 0-.., w = "" Ll ~ " Ll = < = ~ "' w = ~ ~ = = = ,= < 0-u ,= = < 0-= = < ~ = w ~ = = Ll = I::! ii§ ~ " ;,e ,. ~ = ,. < = = = "' = = < = = ~ ,. = = ~ "' w ;,e ~ = w ~ = ci w c:: ,= = w g ~ ~ = = 0- = w c:: u w 0-~ w ;,e = = w ~ = = = ~ = w = 5' = = 0- w Ll 5' = w ~ ~ = ~ = w "' = "' ~ "" = < "' = = ,= < "' = e "' = .. ~ = "' < = = ~ "' "" "' = = < 1 ~ 0-.., w = "' r,i = Ll = < = ~ "' w Sil ~ = i'= = w 0-= = 0- w ;,e w = < = = = ,= < "' ~ ~ ~ = = < ," 0-w Ll = = Ll ;a;; "' w = ~ < = "' Ll ~ 5= Ll = < cl w = ;a; = 0- = = ,= < ,. = e "' w ;,e = = < ~ = ,. < = = ~ "' 3'-Cf" 3 12 GMU HEIGHT 13'-0" BUILDING HEIGHT E j A-3 A.-3 8'-0" CEILING HEIGHT GMU HEIGHT D llt----+f;~I FAMILY 'II' " ' SECTION A-A El FAMILY I I'' : I '! SECTION C -C BUILDING SECTIONS SCALE, 3/8"= 1 '-0" , I'. , , : i '. ' " 0'-0" FINISHED FLOOR A ATTIC SPACE - () I U) INSECT SC.REEN BACK FRAMINcS PER PLAN--:-\, SIDE OF FRAMINcS ----'s,,---- 2X SOLID BLK'cS = z 2 MIN . ~----,,- il'lALL FRAMINcS REFER TO THE STRUCTURAL DRAll'llNcSS S/8" cSYP.,-----s;~-----ll SD. (TYP.) WEEP SCREED POP RIVET TO COUNTER FLASHING ROOF TO l"lALL FLASHINcS POP RIVET TO PANEL 2X6 FDN. cSRADE SILL il'l/ POJ/'lER DRIVEN ANCHORS @ 32" o.c.. I.C..G.-ES REPORT NO. ESR-I100 PENETRATION INTO C.URB I" Ml ,..,_.,"""'"77"'/ DOUBLE TOP PLATE 1/2" C.LR. OF FRAMINcS AT NON-BEARINcS l"lOOD FRAME il'lALL GONc.RETE CURB CONCRETE FLOOR ~ METAL ROOF PANELS ATTACH FLASHINcS TO SUBSTRATE il'l/ i;fOxl" PANCAKE HEAD @ 12" O.C. INTERIOR WOOD FRAME WALL A B MEN'S SECTION B -B (OPEN TO CHASE) MEN'S 2 z /4'. _J lL 0 1i . . llJ .. . ·I .. ' lL . •' I-5 ' . . . I .. . . I!) llJ 0 I ir-----..I SECTION A CUPOLA FLASHING B CEILING TO FRAME WALL C PONY WALL ON CURB 0 II 13'-0" BUILDING HEIGHT 10'-0" GMU HEIGHT l'-0' i-------+,,<++------------1I4 CHASE D -----------.j 5 ---------15 QJ DOUBLE 2x6 TOP PLATE 0'-0" FINISHED FLOOR VARIES JI'-{/ SLOPF CMU HEIGHT 8'-1" CEILING HEIGHT 0'-0" FINISHED FLOOR 2. ATTACH 2x6 FRAMING TO il'lALLS it'llTH I6d NAILS AT 12" O.C. (PROVIDE BLKG AS REQUIRED) CONNECT TO CMU It'll 1/2" RED-HEAD ACCHORS AT 24" 0. C. 3. 5/8" GYPSUM BOARD BOTH SIDES 4. 2x6 FRAMING AT 16" O.C. 5. 6x4 POST it'llTH 'SIMPSON' HTT22 AS HOLDOV'lN AT FREE STANDING ENDS (INST ALL PER MANUFACTURER) 6 -2x6 FDN GRADE SILL It'll POll'lER DRIVEN ANCHORS ON CONC.RETE OR D.F. SILL it'llTH 5/8" LAG SCRFJt'lS ON PLYV'lOOD 1 -8" it'llDE 6" HIGH CONCRETE CURB 2X6 LEDGER 1/2"---' RED-HEAD ANCHORS AT 32" O.C. SECTIONS NOTES: [jJ METAL ROOFING-OVER PLYl"lOOD, REFER TO THE STRUCTURAL DRAl"llNcSS AND BUILDINcS MATERIALS SECTION 01.6. 2. cSALVANIZED SHEET METAL cSUTTER AND DOl"lNSPOUT, RE.FER TO THE ROOF PLAN AND THE EXTERIOR ELEVATIONS. 3. 8X8Xl6 G.M.U. REFER TO THE FLOOR PLAN AND THE BUILDlNcS MATERIALS SECTIONS 04.0 AND 05.9. 4. FINISHED cSRADE REFER TO THE BUILDINcS MATERIALS SECTIONS 02.0 AND 02.f. FINISHED cSRADE TO SLOPE A MINIMUM OF 1/4"/ FT. Al"lAY FROM THE STRUCTURE. 5. CONTINUOUS C.ONGRETE FOOTINcS. REFER TO THE FOUNDATION PLAN, BUILDINcS MATERIALS SECTIONS 02.1, 09.0 AND 05.3. 6. 4" THICK GONC.RETE FLOOR SLAB, REFER TO THE FOUNDATION PLAN, BUILDINcS MATERIALS SECTIONS 02.1, 09.0 AND 05.3. 1. CONCRETE CURB (8" l"llDE SY 6" HlcSH) AT ALL INTERIOR l"lOOD FRAME l"lALLS. REFER TO THE STRUCTURAL DRAl"llNcSS. 8. 2X6 l"lOOD FRAME GEILINcS JOISTS AT 24" O.C. V'IITH 5/8" THIC.K l"lATERPROOF c5YP5UM BOARD GElLINcS, REFER TO THE BUILDINcS MATERIAL SECTION 0<:!.2. <:!. THIS SIDE OF THIS V'lOOD FRAME l"lALL IS TO HAVE NO FINISH AND OPEN TO THE ROOM. 10 ALL l"lOOD FRAME l"lALLS ARE TO HAVE S/8" THICK l"lATERPROOF cSYPSUM SOARD FINISH l"llTH A PLASTIC LAMtNATE GOVER SELECTED BY THE 01'-lNER. UNLESS NOTED OTHERll'llSE. II. METAL SECURITY cSATE, REFER TO DETAIL 0/D-03 AND THE FLOOR PLAN. 12. l"lOOD FRAME ROOF RAFTERS, REFER TO THE STRUG TUR.AL DRAl"ll NcSS. 19. C.ONTINUOUS CUPOLA AS VENT. MATCH THE EXISTINcS VENT ON THE ADJACENT BUILDINcS. REFER TO DETAILS F, H/D-05, A/D-06 AND THE ROOF PLAN. 14. THIS SIDE OF THIS PLUMBINcS l"lALL HAS NO FINISH AND IS OPEN TO THE C.HASE ROOM AND THE ATTIC.. MASONRY 1/'lALL /I~---.._ GYPSUM BOARD CEILING D CEILING TO CMU WALL CDP 2019-0027 4 DE~ICN architecture ■ planning Kennith L. Chriss A.I.A . C 13351 Exp. 12/31/19 * or c~\.\ r-wApel »vd&fil..., mririfft ts inc r-- N 0 0 I 0) ..... 0 N 0.. 0 0 :!:: E ,_ Q) 0.. ...., C: Q) E 0. 0 Q) > Q) 0 co ...., Cl) co 0 0 571-B Hygeia Avenue Leucadia, CA 92024 (760) 943-0760 rwapel2@cox.net CA license #2825 (9 z Cl) -0 0 _J _J -LU ::) -LL en 0:: ~ LU 0 s 0 0 0:: _J ~ LL Cl) LU LU 0:: I ~ s +-'· LU co z Project # Drawn by Scale As shown Date November 06, 2019 co 0 0 N 0) <( 0 -0 co ..Q Cl) .:::: co 0 Q) t:: 0 z Q) 0 0 Q) Cl) co 0.. "sJ" 0 r-- L!) BUILDING SECTIONS SHEET A-4 lill.~l}THQRIZED VEHJGliS PARKED 2 -1/4" :CSStBLI; LAYING DIA. 0151 C:AFIDS OF: GALV. SPftlAI: LICE TES ISSUED FOR PER NS 'IT~ OiSABJLITIES THRU-WILL E fDW D AWAY AT THE WNE:f!~ EXPl:NSE BOLTS TO ~tCLES l~A\'3-E ll;lEilAT OR BYT !.Ef{HOt.lNG )( <( r:; Q INISHED GRADE ' "' ENTRANCE ACCE5 SIGN ll'x22" MIN. W/BLACK LETTERS ON CONTRASTING WHITE BACKGROUND. NON-GLAis::E. 5EE B/D-0I 2' DIA. GAL V. Cl. POLE ,II "' ' ~ 0" D!A. FT'G WI l'-0" BELL CAP z ,_. I: . r 22" MIN. UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING DISTINGUISHING PLACARDS OR SPECIAL LICENSE PLATES ISSUED FOR PERSONS WITH GISAB!UTIES WILL BE TOWED AWAY AT THE OWNER'S EXPENSE TOWED VEi-!ICLES MAY BE RECLAIMED AT OR BY TELEPHONING \ I' HIGH MIN. BLACK LETTERS ON A WHITE FIELD, SEE 5ITE PLAN FOR LOCATION, TEXT TO BE REFLECTIVE PORCELAIN ENAMEL, NON-GLARE. 113 GA. GAL V. S!-IT. MTL. SIGN VAN T,-;15 SIDE 5EE SITE PLAN SLIP-RESIST ANT FINIS!-! ON RAMP. ONLY. 5EE DETAIL5 J/D-0I .AND !-VD-01. CAR OVERHANG W/ NO WHEEL STOP =LARED S!DES oF CURB RAMP 1,B 5LOPE MAX. 6" CONC. CURB PAINT BLUE 6" CONC. CURB . 12" WIDE_} [7 BORDER GROOVES 1/4" ROUNDED · -,;i 3/4" -___ __:.J~O~.C~-==7 PAINTED Wl-lI•E ,-----, LINES, 36' O.C. MAX. HANDICAPPED EMBLEM 3' $QUARt: --~ HANDICAPPED ------,-'k SIGN PO$T, TYP. CONC~ W!-IEEL STOP, SEE DETAIL M/D-0I ~ SEE DETAIL J/D-OL ,,,-----4' WIDE PAINTED BLUE LINES .,--"NO PARKING' PAINTED IN 12" Wl-lITE LETTERS AT B'-0" VAN LOADING SPACE PER CBC SECTION II2'::lB.4.2. SEE t:/D-0I DETAIL I . Q ' N \t 4'-0" 1 ( 3'-0' MINIMUM J Jk TRJNCA TED DOMES 1 1,r---@=1.-=-0-,-' -::Tc:o:-2:c_-4-:-,c-'5':-f'=--:A-=:C:-::IN-;-1G7·-C=-/c::C:---,nl i .........................• , ........................... , •••••••••••••••••••••••••• o••••••••••••••••••••••••••• • ••••••••••••••••••••••••••• •••••••••••••••••••••••••••• ··················••-•······· • ••••••••••••••••••••••••••• •••••••••••••••••••••••••••• •••••••••••••••••••••••••••• •••••••••••••••••••••••••••• •••••••••••••••••••••••••••• •••••••••••••••••••••••••••• ••••••••••••••••••••••••••• lb' TO 2A' PLAN -TILE NOT TO SCALE 0-00 00 000 000 0 00 000 0 SEE NOTE "2 MIN. ON BLUE FIELD. SEE DETAIL D/D-01. B'-0" -,;i VAN ogo PARKING 'l: og&&o l,,-..~---------------------"'"'117"""11::------------------------;7" ..... -----------------------------------------------1N -"i<--J--mnm?-----';oOOOOOO OO"!<---~lffj!j,, 0 a\ z -00000 000000000 ooo A ENTRANCE SIGN B ENTRANCE SIGN C PARKING STRIPPING ,-~ i--1 0000000000000000000 -"ls-fi>"1-!+iiU,.U//.'Lll/J,~"""',S/.f----,""!s-l . L 00000 000000000 ooo 1 -... p.....iC...---------------------"'"'IP,,,""";....----------------------t------------------------"T-------~---_-_-_----~===.---~------t 000000@0 00 <!-' .... SLUE PAINTED FIELD ·.·v ;;Ac:=ED BLUE LINES_ I 36" '. ./ 36" 0.C. MAX. I' 6' -~~., ;, 1!' ~~mt TYP. WHITE PAINT EMBLEM MARKING INTERNATIONAL SYMBOL OF ACCESSIBILITY D PARKING EMBLEM 2 -l/4" DIA. GAL V. THRU-BOL TS NOTE, FINISHED GRADE ACCESSIBILITY SIGN 7"xl0' MIN. W/WHITE FIGURE ON CONTRASTING BLUE BACKGROUND, NON-GLARE. 2" DIA. GALV. C.I. POLE 0" DIA. ;=T'G W/ 1'-0" BELL CAF SEE !-I/D-01 FOR VAN ACCESS SIGN PET.AIL$ J ACCESSIBLE PARKING SIGN - ; . . m,aa run"' ; ,, ;,' 2% MAX. SURF.ACE UJALL SIGNAGE <TYP.! "~·D NOT To sCALE .so· TO l.4" D=I'<-" II $LOPE IN ANY MOUNTED\ LNOTE, DIRECTION SIGNA.GE PATTERN, SIZE ~ ORIENTATION ARE PER MANUFACTURER'& RECOMMENDATION I / " ! t t~ i ! I NOTE, THE WORDS "NO PARKING" SHALL BE PAINTED ON THE GROUND WITHIN EACH LOADING AND UNLOADING ACCESS AISLE. THIS NOTICE SHALL SE PAINTED IN WHITE LETTERS NO LESS THAN 12" HIGH AND LOCATED SO THAT IT I$ VISIBLE TO TRAFFIC ENFORCEMENT OFFICIAL$. E ACCESS AISLE ACCESSIBILITY SIGN~ WITH WHITE FIGURES ON CONTRASTING BLUE BACKGROUND, NON-GLARE 0 PARKING ONLY MINIMUM .....,.;.F...clN-'E'---'-$ ___ 25;..;0~ Wl-lITE LETTERS VAN ACCESSIBLE ON CONTRASTING BLUE BACKGROUND, NON-GLARE "VAN ACCESSIBLE" SIGN AT +80" AT ACCESSIBLE STALLS ONLY K ACCESSIBLE PARKING SIGN RESTROOM (' " '\. / BRAILLE TABS I 1/4" T!-IK. B LAMINATE LUE PLASTIC J D SYMBOL W/W!-IITE I -• INSCRIBED EMBLi::M 1/B DEEP F DIRECTIONAL SIGN GRADE ' - 3' PAINTED BLUE LINE$ 36' 0/C MAX. AT 4!::>' TO BOUNDARY ---,~-i,&0 MAX w Q <( !l'. " 0 !- i r: Q • ,II ~~ CROSS $LOPE /1 SFE SITE PLAN ;=oR EXCEPTION$. L ACCESSIBLE PATHWAY UJALL MOUNTED 5lGNA6E LETTER1N7 RAISED 1/32" PUSI-I/OR PULL FLA.TE KICK-PLATE H!:::IGHT OF"-_,-- DOOR ELEV. /TYP.! LE,TER!NG !?IB" MIN TO 2' MAX G ACCESS SIGNAGE POOR MOUNTED 5IGNA6E /TYP.! NOTE, -PICTOGRAMS AND/OR Ll=TTERJNG AF£ NOT REGl. ON D~-MOUNTED SlGNAGE. CORRESPONDING GRADE II 6RAILLE 3-0" TO WALL. CONCRETE-~ WHEEL STCJP PAVED $1.JRFACE 2· 4'-0' CURB, OR ST ALL END 2' d) EXPANSION ANCHOR 1/ M CONCRETE WHEEL STOP NOTES, I. DETECTABLE UJARNING! SURFACE COLOR 51-iALL 6E YELLOW CONFORM!NG! TO FEDERAL $T AND ARDS 595B TABLE Iv, COLOR NO, ;13&3e, OR AS 5FEC!F!ED BY Tl-IE AGENCY. COLOR $1-iALL BE f-40MOC.--ENEOU5 TI-IROUGI-I Tl-IE TILE. 2. TRUNCA7ED DOME TOP DIAMETER OF 50"• OF T!-lE 6A5E DIA'1ETER MINIMUM TO bl?% OF T!-lE 6A5E DIAMETER MAXIMUM. 3, DURING AND AFTER T!-lE TILE INSTALLAT!ON AND Tl-IE CONCRE7E CURING 57 AGE, IT I5 IMPERATIVE TI-IAT TI-IERE !5 NO WALKING, LEANING OR EXTE~'!AL FORCE& f'LACED ON Tl-IE TILE TO ROCK Tl-IE TILE, CAUSING! A VOID BETWEEN Tl-IE UNDERSIDE OF TILE AND CONCRETE. H TRUNCATED DOMES TEXT TO BE A CONTRAST COLO~ FROM eACKGROUN~, a Ill I-~ J J :;\ Q "' N TACTILE SIGN BRAILLE TABS 'EXIT" AT GRADE LEV1=L CH.ANGE, I EXIT 5TAIR DOu.N' AT STAIRWAY 3/B' MIN TO 1/2' MAX BETWEEN TEXT AND BRAILLE ' D .. ,i• l ~, -\ -'l<---i--, _J . j, \ J 1'-1!,' ,,> I SIGNS CONTAINING c'..T ACT!LE ~ CI-IARACTERS-51-iALL 6:: LOCATED 50 TI-IAT TI-IERE 15 AN 18' CLEAR FLOOR AREA CENTERED ON Tl-IE TACTILE CI-IARACTER5 DOOR El.EV. AT lffERl0FI DOOR PLAN AT Ii IEHIOK TACTLE SIGN REQUIREMENTS; 1. A tACTILE SIC.~ STATING 'EXIT' AND CCli"1FL TING UJ!TJ..! Aln.f &4AL.L 65: PROY'!DED ADJACENT TO :ACH DOOR TO AN EXIT PA&$A(.EWAY AND THE EXIT D15cHA"""E- 2. LETTER& AND NU1"16ER5 ON &IGN& &l-lALL HAYE A WIDTH-TO-HEIGHT RATIO OF BET'i.l.lEEN. 3:S-AND ld AND STROKE I.U!DT!-l-TO-HEIGHT RA1"1'..0 6ETUJEEN i:5 AND t, 10. 3. CHARACTERS-AND SYMBOLS S~ALL CONTRAST WIT+-! T4EIR BACKGROUND. 4. Cl-lARACTERe-~ALL CONFORM TO TI-IE FOLLOWING:, A LETTERS AND NUM6ER5 ON 5!GN5 5HALL BE RAISED 1/32' MINIMUM AND 5HAL~ 6E A5N$-5ER!F UPPERCASE CHA.'<ACTERS ACCOMPANIED SY GRADE 2 6RA!LLE. 6. RA!5ED OlARACTERS OR 5YM80L& 5HALL BE A MINIMUM, c:?fll !::-/6' l-l!G!-1 AND A MAXIMUM OF :z~r 5. CONTRACTEi? GRADE 2 BRAILLE 5HAl.L 6E U5EP. DOT& &1-JALL 6E I ;.e,• ON Ci'NTER !N EACH CELL UJITH 2 lie>' 5F"ACE BETWEEN CELLS. DOT5 SHALL SE RAISED A MINIMUM OF f /~' ABOVE THE 6AC~. &. Si:C,-NS SHALL 6E INSTALLED ON THE WALL ADJACENT TO THE LATCH SID: OF THE. DOOR UJHEisl: THERE !$ NO WALL SPACE ON THE LATCH SIDE. !NCLUDING: DOUBLE LEAF DOOR&, SIGNS &HALL eE PL.ACED ON THE NEAREST APJACENT WALL, PREFER.A6L Y ON Tt-lE R!G:1-lT. M-OUNTING HEi:C,-HT 5'4ALL 6E 6e>' A60\IE THE FlNIS>-IED FLOOR TO THE CENTER OF THE &IGN. MOUNTING LOCATION &l-lALL 6E DETEl'MlNED 60 THAT A PERSON MAT APPROACH WITHIN 3' OF THE SIGN WITHOLrT ENCOUNTEli<ING, PROTRUDING 06JECT5 OR ST ANDING W!THIN THE 5W!NG OF A DOOR I TACTILE SIGN 0 CDP 2019-0027 4 DE~IGN architecture ■ planning Kennith L. Chriss A.I.A. r-- N 0 0 I 0) ,,- 0 N CL 0 u _, E ,_ Q) CL _, C: Q) E O,_ 0 Q) > Q) 0 Cll _, Cl) Cll 0 u C 13351 Exp. 12/31/1 (.9 z (f) -0 0 _J _J -w ::, -LL co 0:: ~ w 0 s 0 0 0:: _J I-LL (f) w w 0:: I I-s +-' w m z Project # Drawn by Scale As shown Date November 06, 2019 a:, 0 0 N 0) <( u -0 Cll _c Cl) ,_ Cll u Q) t 0 z Q) 0 0 Q) Cl) Cll CL ,q 0 r-- I() SITE ACCESSIBILITY DETAILS SHEET D-1 A 8" MIN. KNEE CLEARANCE SIDE ELEVATION b"" MAX. TOE CL:=ARANCEX ·•NOTE, IF A MINIMUM ~ INCHE5 HEIGHT OF TOE CLEARANCE I5 PROV!DED, A MAXIMUM OF 0 INCHES OF THE 48 !NCHE5 OF CLEAR FLOO:'< 5FACE REQUIRED AT THE FIXTURE MAY EXTEND INTO THE TOE SFACE. ACCESS CLEARANCE 1112" CLEAR EXTERIOR BLOCK WALL I 1/2" ALUM HANDRAIL 1/ 17" MIN. v 7J 7( w ...,..!!!!!!!!....,...-'!,,,.,,.---+----"Is: ;z; ---=---i -oi A::'--Li --,-I ~ lli I r ~ G -()W <>) I-\.) )3-1: -t----'k IS" MAX. 48"' MIN. .,, PLAN VIEW I li2' CLEAR GYPSUM !30ARD I 1/2" ALUM HANDRAIL \ ( ~ 3/B' MACHINE- !30L T ANCHOR 3/8' LAG AT WALL I.LI/ !3LOCKING BEI-UND SECTION ELEVATION E GRAB BAR AT CMU F bO" MIN. SECTION ELEVATION BRAB BAR AT WOOD FRAME WATER CL05:T. REF:R TO DETAIL H/D-02 GRAB BARS , REFER TO DETAIL L/D-02 ----,--;7 I I ~ (!1 I ~i-~-i==~====:;=~~~-----~ 0 TO,LET PARTITION, REFER TO Ti-IE INT!"R!OR ELE:VAT!ON$ K AMBll..ATORY COMPARTMENT 42" MIN. PLAN VIEW ~-- I I I ' ~ I ' ' i i r:::=i r:::=i ii I I I FINISHED FLOOR NOTE, TOWELS AND WASTE DRYER SANITARY NAFKINS CUPS 50AF OWNER TO 5ELEC~ AND SUPPLY THE ABOVE ACCE550RIRE AS NEEDED. B ACCESSORY ACCESS HEIGHTS i 1/2" 'CLEA MET AL PARTITION,Rt=Ft:R TO THE INTERIOR ELEVATIONS AND THE FLOOR PLAN i-1/2" DIA. 5.5. GRAB r BAR WITH CONCEALED / MOUNTING ~~'-----t~ I SECTION 5.5. COVER PLATE MET AL SCREWS THROUGi-1 PARTITION ' \ \ ELEVATION G BRAB BAR AT METAL PARTITION !'>4" HIN. 39' TO 41' 12' 5T AINLE66 &TL -s;:-J.__ GRA66AR6 1-1/:1' DIA MAX ,!) "' ~ J 42'M!N J ;;l >k--L,,-<E="'----:::----"k WATERCL05E:T FINI6HED FLOOR SECTION L AMBll..ATORY GRAB BARS H 42" MIN. Ii 18" HIN. STAINLESS STEEL GRAB BARS 1-112" DIA MAX. WATER CLOSET _J WATER CLOSET GRAB BAR AND T,P. DISPENSER LOCATIONS .· 24' MIN. T.P. DISP. F!Nis+-!ED FLOOR 13 1/2" MIN. WALL HUNG TYPE STALL TYPE NOTE, l. CLEAR FLOOR SPACE TO BE 30'X48" IN FRONT OF FIXTURE. 2. FLUSl-l CONTROL 51-lALL Bt: MOUNTED 44" ABOVE FINISH FLOOR M ACCESSABLE URNIAL 30" -WHEN DOOR sw:NGS TOWARDS EXTERIO's: ~l:i , r ;.-,,• ___ H_IN_.~-; WALK A 00"X00" MIN. LEVEL AREA IS TO i:3E PROVIDED _,, ,__ LEVEL AREA l, 00" k 71 M"N 71 ,., . -WHEN DOOR SWINGS AWAY FROM EXTERIOR WALK A 48"WX44' LEVEi.. AREA IS TO !3E PROVIDED .,, MIN. 7, C DOOR ENTRANCE CLEARANCE SHOOT 5URFAC PUSH S H I~~ ." F!NI5H FLOOR - ~ 1"- ' . j, 32'MN. I ,r z -i:: "' . l • r: lx ~; ~ I: 1 o,; "'I..- I I ' NOTE, -LOCKING DOOR TO PROVIDE LEVER TYPE HARDWARE PER SECT. ii33B2.5 -MAX. EFFORT TO OPERATE DOORS NOT TO EXCEED 8-1/2 LBS. FOR EXTERIOR DOORS, 5 Li:3S. FOR INTERIOR DOORS, 15 LBS. FOR FIRE DOORS PER SECT. 11336.2.5 I ACCESSABLE DOOR STANDARDS . U1 u\ -1' --~3~5~2~5~"~M~A~X~. ~r-FINISHED FLIP DOWN FACE OF BABY WALL • CHANGING TA!3LE = FRONT ELEVATION FINISl-lED FLOOR x -<t SIDE :r: ELEV A TION N 0\ NOTE, OWNER SHALL A1PROVE MANUFACTURER, STYLE AND COLOR N CHANGING TABLE t I WALL 5IGNAGE !TYP.) DOOR MOUNTED\ 5!GN..4GE \ r.===\===;i WALL MOUNTED 5!GNAGE LETTERING RAISED 1/32' DOOR MOUNTED SIGN.AGE (TYP.) NOTE:, P!CT~'-15 AND/0~ LETTERING ARE NOT RE:Q. ON ~~-r.,-;;J.;---1\ oooi,;a~HOUNTEO 6:tGNAGC:.. KICK-PLATE_} DOOR ELEV. <TYP) ~~:::::.:.~ J HEIGHT OF''-_...- LETTER!NG :;,/8" MIN TO 2' MAX CORRESFONDING GRADE II BRAILLE D DOOR ACCESSABLE SIGNAGE · 5 1/8" TO 5 3/8" DOOR__/ DOOR HANDLE SHAPE, STYLE, AND FINISl-l MAY YERRY J LEVER TYPE HANDLE WOOD FRAME: WALL ON CONC.7 CUR6 / WATER CLOSET BOWL \ SECTION () !-• -,S) "" " ;:::o ,n <'4 N FLUSH VAL Vi:' ZURN 21203-NR4 6RACKET, PROVIDE SOLID BL<r--KJNG A5 R=QU!RED / F!N!6HED FLOOR 0 WALL HUNG WATER CLOSET CDP 2019-0027 4 DE~IGN architecture ■ planning Kennith L. Chriss A.I.A. t-- N 0 0 I 0) .,,.. 0 N (L 0 () :!:: E ,_ Q) (L -C: Q) E C. 0 Q) > Q) 0 ct! -en ct! 0 0 C 13351 * Exp. 12/31/1 '1/; (9 z Cf) -0 0 _J _J -w :::> -LL cc 0::: ~ w 0 $ 0 0 0::: _J t-LL Cf) w w 0::: I t-$ ,+,J w (\1 z Project # Drawn by Scale As shown Date November 06, 2019 BUILDING ex:> 0 0 N 0) <( () 'O Cll .c en ,:: Cll () Q) t::'. 0 z Q) 0 0 Q) en Cll (L ,;;t 0 t-- LO ACCESSIBILITY DETAILS SHEET D-2 Ei c:: i ~ i'E El c:: 8 ils A WINDOW HEAD CMU EXTERIOR WALL CAULK WEATHER TIGHT VINYL FRAME SINGLE PANE WINDOW DOOR, SEE FLOOR FLAN 1 EXTERIOR GRADE CONCRETE F'...OOR \ I \ ' G EXTERIOR DOOR SILL RELIEF LINE---..:"'--, H.W. SUPPLY---<P'<!-K .---.I:¾----C.W. SUPPLY CJ ! c::J I THIS INSTALLATION IS FOR TYPICAL CONDITIONS, THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE ACTUAL CONDITIONS. II] SHUT OFF VAi..VE, USE FLEXIBLE PIPE CONNECTIONS TO WATER HEATER II] BRACE WATER HEATER TO WALL WITH 1-1/2" GALV. 16 GAUGE METAL STRAP, ANCI-IOR TO WATER HEATER W/(1) 1/2" LONG SHEET METAL $CREW, ANCHOR TO WALL FRAMING WITH I' LONG GALVANIZED 5µEET MET AL SCREW. ~ PROVIDE 2X4 BACKUP BOARD BETWEEN HEATER AND WALL Gil RELIEF LINE TO EXTERIOR FROM P. ! T. VALVE. TERMINATE LINE AT 0' FROM FINISH FLOOR AT THE EXTERIOR OF THE BUILDING WITH A 90" ELBOW. ~ PROVIDE 18' 1-!IGI-I RAISED PLATFOF<M If LOCATED IN A GARAGE. [f2] FIRST 5 FEET OF FIFES CLOSEST TO WATER HEATER TANK, NON RECIRCULATING SYSTEMS, INSULATED (R- OR GREATER) [l] FIFING INSULATED BETWEEN HEATING SOURCE AND INDIRECT !-!OT WATER TANK NOTE, CONTRACTOR MAY USE A WATER !-!EATER SEISMIC STRAPPING KJT IF APPROVED 6Y MANUFACTURER PROVIDE r.c.c. REPORT TO INSPECTOR M ELECTRICT WATER HEATER CMU EXTERIOR WALL ROUGH OPENING CAULK WEATHER TIGHT VINYL FRAME SINGLE PANE WINDOW CAULK WEATHER TIGHT CMU EXTERIOR VINYL FRAME WALL SINuLE PANE WINDOW G ::[ ;?; GZ :::l w 0 ll ill C) B WINDOW JAMB C WINDOW SILL 6YP. 60ARD HEADER FER FLAN ROUGH WOOD SHIM )-C.YP. BOARD OPENINC. WOOD FRAMING WOOD SHIM-, ALUMINUM -~ WOOD FRAMING GYP. BOARD DOOR FRAME DOOR INSULATION · DOOR I INSULATION ~DOOR, SEE I -TRIMMER \L_GYF. BOARD ALUMINUM _ __, DOOR FRAME DOOR, SEE FLOOR PLAN FLOOR FLAN H INTERIOR DOOR HEAD I INTERIOR DOOR JAMB •NOT: AFFLlCA:3LE TO 5DC..<E C.A5 AND ELECTRIC UTILITY LINES. ELECTRIC : 6AS I SEWER I WATER METAL I I [<UNCOATED) I I 0 METAL ------1----l--r-,-TME~--- --I ---+--~/ -+--o-~-- ~roMETAL coNDU,T I _J NON-METALJ_NoN-ME7AL ,,,;,,,a 0 I M:':TAL ' I (COATED) I Ric.ID METAL I -0 -I -· -0 -T -0-WATER ELECTRIC CONDU. IT _ L NON::META~ ____ -1. -,,.----,..,,-,1 . 0 ' 0 I I -NO BURIAL REQUIREMENT <RECOMMEND 12" TO PROTECT FROM MECHANICAL DAMAGE .AND FREEZING) RIGID METAL CONDUIT 0" MIN. RIGID PLASTIC CONDUIT IB" MIN DIRECT BURIAL CABLE 24" MIN. ~~b~JRECT 8URIAJ __ -1-NON-METALj I r-, I <N.E.C. ART. 300-5 EXCEPTIONS APPLY, I.E., 0' LESS DEPTH FOR 2" CONCRETE PAD OVER CABLE± 300 V. RESIDENTIAL BRANCHES WITH 30 A. BREAKERS [ MAY BE AT 12", ETC) _________ _J METAL - GAS ( AJ 0" ABOVE GROUND <UNCOATED AND UNWRAPPED). (B) 12" BELOW GROUND <FACTORY COATED OR MACHINE WRAPPED). I I I I I I I I I I NON-MET AL -I NOTE, PLASTIC GAS PIPING SHALL HAVE AT LEAST EIGHTEEN (IB) INCHES (0.5M) OF EARTH COVER OR OTHER [ EQUIV AL ENT PROTECTION. RISERS, INCLUDING 1 PREFABRICATED RISER INSERTED WITH PLASTIC PIPE, I Sl-fALL Bi= METALLIC AND SHALL BE WRAPPED OR COATED TO A POINT AT LEAST SIX (6) INCHES (152.4 MM) I ABOVE GRADE OR PROTECTED IN AN APPROVED , MANNER WHEN A RISER CONNECTS UNDERGROUND TO I PLASTIC PIPE, THE UNDERGROUND HORIZONTAL METALLIC [ PORTION OF THE RISER S!-lALL EXTEND AT LEAST Tl-fIRTY I (30) INCHES (0.10M) 6EFORE CONNECTING TO Tl-lE PLASTIC PIPE BY MEANS OF AN APPROVED TRANSITION I FITTING OR ADAPTER I N UTILITY BURIAL STANDARDS ~/ I I I ~['fr< NON-METAL -12" MINIMUM <PLASTIC) (SPECIAL NOTE, ASBESTOS Ct:MENT I WATER PIPE MAY BE L USED -DEPTH 18" J ---------- SEWeR MET AL -NO BURIAL REQUIREMENT (RECOMMEND 12" TO PROTECT FROM MECHANICAL DAMAGE AND FREEZING. NON-METAL -< A) PIPE APPROVED INSIDE BUILDING 12' MINIMUM. <IR, ABS, PVC, CAST IRO'l) (B) PIPE NOT APPROVED INSIDE BURIAL -SEWER TO BE 12" 6ELOW WATER LINE WITH WATER PIPE TO ONE SIDE ON A SOLID SHELF -TOT AL DEPTH 23' <I.E., CLAY) ROUGH OPENING OPENIN6 CENTER LINE -- OF WINDOW -----1 VINYL FRAME WINDOW CMU SILL D JOINT WINDOW JAMB DOOR, SEE PLAN / FLOOR FINISH I / / /' / // \ \ c___ CONCRETE SLAB J INTERIOR DOOR SILL ,_ l ' ' -~ , / ' "- ' NOTE, - '• 4'' 1.---' r,-o _,.,,,------. ' , , /. I y- I/ I/ i;. -- ~ I, I h ; §, ' I " " ,, ' I ~ 2"X2" METAL GATE FRAME l 'SQ. MET AL GA TE PICKET$ ACCESSIBLE LEVER AND HARDWARE I/ 4' FLAT SUPPORT STRAr' FIELD VERIFY THE ROUGH OPENING FOR THE GATE 0 GATE ELEVATION R JAMB CONCRETE BLOCK W:rt=---(2) NO. 4 REBAR EXTEND 24' MIN. PAST OPl=NING /1--,...-,,L-,,<..f----"T" ANCHOR CAULKING METAL DOOR FRAME i-----DOOR SEE- FLOOR PLAN E EXTERIOR DOOR HEAD 1/4" THK. PLASTIC LETTERS CONTRASTING COLOR FOR LETTERS AND BUILDING BACKGROUND NOTE, ADDRESS NUMBERS SHALL COMFL Y IAIITH TABLE A IN CMC SECTION 21.41.040, SEE EXTERIOR ELEVATIO'-lS FOR THE LOCATION OF THE STREET ADDRESS NUMBERS K ADDRESS NUMBERS 2 l/2'x2'x3/10' ST'L FRAME/GAL V. AFTER WELDING AND GRINDING SMOOTH 5-!B"~ ST'i... CANE BOLTS W/ SECURITY $TOPS DECORATIVE PATTERN SEE EXTERIOR ELEVS. Ill-----:::::~ I li2"xl li2'x3/l0" WELD TO FRAME MT'L. CANE BOLT STRIKE _.---FINISHED CONC. P CANE BOLT s JAMB CONCRETE BLOCK z:=:rl=,___ (2) NO. 4 REBAR EXTEND 24" MIN. PAST OPENING f+---/-,Llf--'T" ANCHOR CAULKING MET.AL DOOR FRAME 1-----DOOR SEE- FLOOR PLAN F EXTERIOR DOOR JAMB I 112" GAL TUBE I 1/2 "x3/l6' SHAPED GALV. STL PLATE 1/4 l=LEVATION FLAN L GATE HINGE IN CMU Q 1/2 "<!> C.AL V. A.B. CDP 2019-0027 4 DE~IGN architecture• planning Kennith L. Chriss A.I.A. I"- N 0 0 I 0) ...- 0 N Cl. 0 0 ..., E ,._ Q) Cl. ..., C Q) E a. 0 Q) > Q) 0 ro ..., en ro 0 0 CJ z (/) -0 0 _J _J -w :J -LL co 0::: ~ w 0 s 0 0 0::: _J I-LL CJ) w w 0::: I I-s ~ w co z Project # Drawn by Scale As shown Date November 06, 2019 MISC. 00 0 0 N 0) <( 0 -0 ro ..c en ,._ ro 0 -.@ 0 z Q) 0 0 Q) en ro Cl. '<;f" 0 I"- I!) ARCHITECTURAL DETAILS SHEET D-3 = I" "' "' 0 = ~ "2 "' = z = 5 ~ .., ~ = "' ~ u = < ~ = -~ 0 = 0 e= < ~ u e= = < ~ = = < ~ = ~ en = 0 u = I" ~ ~ ~ is e'= "' "' = ,. < = = en ;s = = < = 0 e= < "' = 0 ~ "' ~ t, ~ en = c ~ c:: e= c5 g ~ u ~ ~ = ~ cc '3 ~ ~ i en ~ ,. e'= I = I 0 ~ en = = E B = 5 0 = ~ ~ u 5 ffi en ~ 0 ~ = ~ "" = ~ "' = < "2 = 0 e= < "' = 0 ~ = = = < "' = ,. < = = "2 e'= "' "' = ,. ~ ~ "" ~ = "' u "' "' u = < = "' "' w = -~ 0 c= = ~ ~ 0 = ~ ~ e'= ~ = < en = 0 e= < fee en ;;l ~ = ,. I" ~ ~ u = 0 u = "' "' w = ~ < = "' u ~ = u = < ci ~ = > 0 = ~ '5 e= < "' = 0 ~ as ~ e'= = = < '"' = 1 !! = = en ;s \ > \ \ ' ! 85.1 \ I I ! I I I -i-85.3 I Sk/ ~I ' "' ',!; ' +, ' '-I;: '+ ' '+ ' '+ '• "' "' "' "' ',!; ' ' ':-f; ' \ \ \ . . \ ~ \ \ ~r.\ \ \ (N) 6" SEWER LINE E7A- ( CONCEPTUAL GRADING & DRAINAGE PLAN ! I I (}00 ◊ ~ \ \ \ I I I I f 90.06 TG 88.89 INV x,,,(o vJ I r~ 90.24 FG / / ~, t ( \ 91.80 FS \ . TG 89.06 INV 91.95 FS ~ 91.64 FS 91.40 TG \ \ \ \ I ' \ \ I I / LEGEND DESCRIPTION SYMBOL EXISTING CONTOURS PROPOSED CONTOURS EXISTING WATER MAIN EXISTING SEWER MAIN --18{) ---------/lBo.,._ __ _ ----W---- ···· s. DIRECTION OF DRAINAGE (1% MIN.) PROPOSED SEWER LATERAL ----S----- FINISH SURFACE FINISH GRADE TOP CURB TOP OF PIPE EXISTING STORM DRAIN PIPE PROPOSED STORM DRAIN PIPE PROPOSED 6" PVC DRAIN PIPE PROPOSED D.G. PROPOSED 12" NDS CATCH DRAIN W/ ATRIUM GRATE PROPOSED PLANTING AREA KEY NOTES II] EX. INLET-PROTECT IN PLACE ~ EX. 12" PIPE TO REMAIN ~ REMOVE EX. 18" PIPE [±] EX. 18" PIPE TO REMAIN '51 INSTALL 24X24 BROOKS BOX 1...,eJ W/TRAFFIC RATED GRATE fs1 INSTALL 74 LF OF NEW 18" ~ HDPE STORM DRAIN PIPE [Z] EX. DECORATIVE WALL-TO REMAIN [ID EX. DRAIN INLET TO REMAIN-REMOVE CMU WALLS-ADJUST GRATE AS NEEDED fgl EX. +/-6' OF 18" STORM DRAIN PIPE ~ TO REMAIN [2j CONNECT NEW 18" TO EX •. 18" PIPE [TI REMOVE EX. AC. PATHWAY & HANDRAIL ~ INSTALL 2x4 BENDER BOARD EDGE [j]] INSTALL 3.5" THICK STABIUZED DECOMPOSED GRANITE PAVING HAl INSTALL 12" NDS CATCH BASIN W/ ~ ATRIUM GRATE ~ INSTALL 6" PVC DRAIN PIPE [§j CONNECT 6" PVC TO NEW 18" PJPE [zl CONNECT 4" DOWNSPOUT TO EXISTING CATCH BASIN (UNDERGROUND) ESTIMATED GRADING QUANTITIES: CUT: 125C.Y. FILL: 0 NET: 125 C.Y. CUT 0 /2 .J • Lj- \ . "" \.~_) ( ~\ ~\ FS FG TC TP I I □ P.A. \ \ \ +\ +, \ \, \ ~. \. '. -f: N 0 5' 10' 20' EB SCALE 1"=10' CDP 2019-0027 4 DESIGN architecture• planning Kennith L. Chriss A.I.A. PREPARED BY: dk Greene Consulting, Inc. r-- N 0 0 I 0) ...... 0 N (l.. 0 () ..... E .... Q) (l.. ..... C Q) E 0.. 0 ~ 0 ro ..... (/) ro 0 () P.O. BOX 143 BONSALL, CA 92003 (760) 310-9408 dk.Greene Consulting, Inc. (9 z Cl) -□ 0 .....J :::! w :::) - CO LL ~o:: 0~ o> 0:: 0 I-.....J Cl) LL ww 0:: I $~ UJ co z Project # Drawn by Scale As shown Date November 06, 2019 CX) 0 0 N 0) <( () "C ro ..Q (/) ;:: ro () -Q) t 0 z Q) 0 0 Q) (/) ro (l.. -.;j" 0 r-- 1{) CONCEPTUAL GRADING & DRAINAGE PLAN SHEET C-1 1 I +79.7! i 6 ) f--- 1 CONCEPTUAL UTILITY PLAN I / C'o EXISTING NURSERY BUILDING 84.2 +I l I 1 1 LEGEND ----w----- ---;ffi]i---- --s--- -----,[I]r--- co 0 I EXISTING POTABLE WATER LINE PROPOSED NEW POTABLE WATER LINE EXISTING SANITARY SEWER LINE PROPOSED NEW SANITARY SEWER LINE SEWER CLEAN OUT PROPOSED NEW ELECTRICAL I 0 10' 30' SCALE 1 "=30' N 60' EB CDP 2019-0027 4 DE~IGN architecture• planning Kennith L. Chriss A.LA. C 13351 * Exp. 12/31/1 OF C ~ dk Greene Consulting, Inc. I'-- N 0 0 I O') ..... 0 N a.. 0 0 -E '-(]) 0.. -C: (]) E P.O. BOX 143 BONSALL, CA 92003 (760) 310-9408 dk:Greene Consulting, Inc. (9 z en oO co ...J ...J 0 0 -w N O') ::> -<( CC LL 0 "O 0::: ctl ~ ..Cl (/) w .::: 0 ctl $ 0 0 -(]) 0 t:: 0::: 0 z 0.. r-...J (]) 0 Q) > (]) 0 ctl -(/) ctl 0 0 en LL w w 0::: I r-$ +-I w ro z Project # Drawn by Scale As shown Date November 06, 2019 0 0 (]) (/) ctl a.. '<t" 0 I'-- U') CONCEPTUAL UTILITY PLAN SHEET C-2 IRRIGATION SYSTEM DESCRIPTION: THE EXISTING IRRIGATION SYSTEM WITHIN THE PROJECT AREA AND IMMEDIATE VICINITY USES POTABLE WATER AND WILL BE RETROFITTED TO FIT THE NEW CONFIGURATION AND SHAPES OF PLANTING AREAS. LOW VOLUME DRIP LINE IS THE PROPOSED IRRIGATION METHOD FOR ALL IRRIGATION WITHIN THE PROJECT LIMIT OF WORK. NEWAUTOMATIC REMOTE CONTROL VALVES WILL BE INSTALLED TO ZONE THE NEWLY PLANTED AREAS SEPARATELY FROM EXISTING IRRIGATION ZONES. REMOTE CONTROL VALVES WILL BE CONNECTED TO THE EXISTING POTABLE WATER IRRIGATION MAINLINE. A NEW AUTOMATIC IRRIGATION CONTROLLER WILL BE INSTALLED THAT USES EVAPOTRANSPIRATION OR SOIL MOISTURE SENSOR DATA AND WILL UTILIZE A RAIN SENSOR. THE EXISTING IRRI.GATION SYSTEM IS SEPARATELY METERED. ! J \ \ \ ,,.- \ .,... ' ,.,. \ ,.,. .,.,. \ ,.,. .,... .,...\ ) '"' ( ~ \ ( i I • • \ '\ EXISTING 10' HIGH YEW PINE HEDGE • '-,, (PODOCARPUS MACROPHYllUS) TO REMAIN '\ \ \ ' • \ MYR COM filLB 32 5g I l ~ (~) 2" Wfo,TE \ • \ EXISTING DRIVE AISLE (A.C. PAVEMHIT) • BK5 MYR COM I 8 5g \ ~-MY-0 -PA~R 19~ 1 SF --flat \ ~ \ EXISTING 10' HIGH YEW PINE HEDGE (PODOCARPUS MACROPHYLLUS) TO REMAIN ' I \ \ EXISTING \O' HIGH MYRTLE HEDGE --~, (MYRTUS COMMUNIS) TO REMAIN \\ '\ BBB \\ 89.2 \ 1 CONCEPTUAL LANDSCAPE PLAN \::. ' . -\ . "~'-~~ ;: .. ,· ., .. · . 8L:~~,:. \§). . : v-\.·· "I AM FAMIUAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION PLANS CONTAINED IN THE CITY OF CARLSBAD'S LANDSCAPE MANUAL AND WATER EFFICIENT LANDSCAPE REGULATIONS. I HAVE PREPARED THIS PLAN IN COMPLIANCE WITH THOSE REGULATIONS AND THE LANDSCAPE MANUAL AND AGREE TO COMPLY WITH ALL REQUIREMENTS WHEN SUBMITTING CONSTRUCTION DOCUMENTS. I CERTIFY THAT THE PLAN IMPLEMENTS THOSE REGULATIONS TO PROVIDE EFFICIENT USE OF WATER." RICHARD W. APEL REGISTERED CALIFORNIA LANDSCAPE ARCHITECT No. 2825 I ) \ \ EXISTING _) (\ GARDEN AREA I / / \ ' ' ) ' I SCALE 1"=10' 0 lAU NOB 24 15g ROS OFF 54 1g EXISTING GREENHOUSE 5' 10' N 20' EB LANDSCAPE NOTES: MINIMUM SLOPE PLANTING STANDARDS PER CITY OF CARLSBAD LANDSCAPE MANUAL: A SLOPES 6:1 OR STEEPER REQUIRING EROSION CONTROL MEASURES AS SPECIFIED HEREIN SHALL BE TREATED WITH ONE OR MORE OF THE FOLLOWING PLANTING STANDARDS: 1. STANDARD #1-COVER CROP AND/OR EROSION CONTROL MATTING: COVER CROP SHALL BE A SEED MIX TYPICALLY COMPOSED OF QUICK GERMINATING AND FAST COVERING GRASSES, CLOVERS AND/OR WILD FLOWERS. SUBMIT THE SPECIFIC SEED MIX FOR CITY APPROVAL PRIOR TO APPLICATION. THE COVER CROP SHALL BE APPLIED AT A RATE AND MANNER SUFFICIENT TO PROVIDE NINETY (90%) PERCENT COVERAGE WITHIN THIRTY (30) DAYS. TYPE OF EROSION CONTROL MATTING SHALL BE AS APPROVED BY THE CITY AND AFFIXED TO THE SLOPE AS RECOMMENDED BY THE MANUFACTURER. o ON SLOPES 3 FEET OR LESS IN VERTICAL HEIGHT WHERE ADJACENT TO PUBLIC WALKS OR STREETS: -WHEN PLANTING OCCURS BETWEEN AUGUST 15 AND APRIL 15, EROSION CONTROL MATTING SHALL BE REQUIRED. -DURING THE REMAINDER OF THE YEAR, THE COVER CROP AND/OR EROSION CONTROL MATTING MAY BE USED. o ON SLOPES GREATER THAN 3 FEET IN HEIGHT, EROSION CONTROL MATTING SHALL BE REQUIRED AND A COVER CROP SHALL NOT BE USED, UNLESS OTHERWISE APPROVED BY THE CITY. 2. STANDARD #2-GROUND COVER: ONE HUNDRED (100%) PERCENT OF THE AREA SHALL BE PLANTED WITH A GROUND COVER KNOWN TO HAVE EXCELLENT SOIL BINDING CHARACTERISTICS (PLANTED FROM A MINIMUM SIZE OF FLATTED MATERIAL AND SPACED TO PROVIDE FULL COVERAGE WITHIN ONE (1) YEAR). 3. STANDARD #3 -LOW SHRUBS: LOW SPREADING WOODY SHRUBS (PLANTED FROM A MINIMUM OF 1-GALLON CONTAINERS) SHALL COVER A MINIMUM OF SEVENTY (70%) PERCENT OF THE SLOPE FACE (AT MATURE SIZE). 4. STANDARD #4-TREES AND/OR LARGE SHRUBS: TREES AND/OR LARGE SHRUBS (PLANTED FROM A MINIMUM OF 1-GALLON CONTAINERS) SHALL BE INSTALLED AT A MINIMUM RATE OF ONE (1) PLANT PER TWO HUNDRED (200) SQUARE FEET. B. AREAS OF APPLICATION -SLOPES 6:1 OR STEEPER ONLY): 1. SLOPES 3' OR LESS IN VERTICAL HEIGHT AND ARE ADJACENT TO PUBLIC WALKS OR STREETS REQUIRE AT MINIMUM STANDARD #1 (COVER CROP OR EROSION CONTROL MATTING). 2. SLOPES 3' TO 8' IN VERTICAL HEIGHT REQUIRE STANDARDS #1 (EROSION CONTROL MATTING SHALL BE INSTALLED IN LIEU OF A COVER CROP), # 2 & #3. 3. SLOPES IN EXCESS OF 8' IN VERTICAL HEIGHT REQUIRE STANDARDS #1 (EROSION CONTROL MATTING SHALL BE INSTALLED IN LIEU OF A COVER CROP),# 2, #3 AND #4 C. AREAS GRADED FLATTER THAN 6:1 REQUIRE A COVER CROP PER STANDARD #1 WITH TEMPORARY IRRIGATION WHEN THEY HAVE ONE OR MORE OF THE FOLLOWING CONDITIONS: 1. SHEET GRADED PADS NOT SCHEDULED FOR IMPROVEMENTS WITHIN 6 MONTHS OF COMPLETION OF ROUGl-t GRADING. 2. A POTENTIAL EROSION PROBLEM AS DETERMINED BY THE CITY. 3. IDENTIFIED BY THE CITY AS HIGHLY VISIBLE AREAS TO THE PUBLIC OR HAVE SPECIAL CONDITIONS THAT WARRANT IMMEDIATE TREATMENT. SOIL MANAGEMENT REPORT, TESTS AND AMENDMENTS: A SOIL MANAGEMENT REPORT SHALL BE COMPLETED BY THE CONTRACTOR, OR HIS DESIGNEE. SUBMIT DOCUMENTATION VERIFYING IMPLEMENTATION OF SOIL ANALYSIS REPORT RECOMMENDATIONS TO THE LOCAL AGENCY (CITY OF CARLSBAD PLANNING DEPARTMENT) WITH CERTIFICATE OF COMPLETION. CONTRACTOR SHALL OBTAIN HORTICULTURAL SOILS TESTS FOR REPRESENTATIVE SOIL TYPES AND PLANTING AREAS WITHIN THE PROJECT AREA AND SUBMIT REPORT($) TO THE LANDSCAPE ARCHITECT AND CITY OF CARLSBAD PLANNING DEPARTMENT (LANDSCAPE REVIEW). PLANTING AREAS SHALL BE AMENDED ACCORDING TO THE RECOMMENDATIONS OF THE SOILS ANALYSIS REPORT. COMPOST AT A MINIMUM RATE OF FOUR (4) CUBIC YARDS PER ONE THOUSAND (1,000) SQUARE FEET OF PERMEABLE AREA SHALL BE INCORPORATED TO A DEPTH OF SIX INCHES INTO THE SOIL. (MWELO 492.6). A MINIMUM THREE (3) INCH DEEP LAYER OF MULCH SHALL BE APPLIED ON ALL EXPOSED SOIL SURFACES OF PLANTING AREAS EXCEPT IN TURF AREAS, CREEPING OR ROOTING GROUNDCOVERS, OR DIRECT SEEDING APPLICATIONS WHERE MULCH IS CONTRAINDICATED. (MWELO 496.6) . MINIMUM PLANTING REQUIREMENTS PER CITY OF CARLSBAD LANDSCAPE MANUAL: ALL TREES (EXCEPT ON SLOPES 3:1 OR STEEPER) SHALL BE A MINIMUM OF FIFTEEN (15) GALLON SIZE. STREET TREES AND PARKING AREA TREES SHALL BE MINIMUM 24" BOX SIZE (PER CAR COUNTRY SPECIFIC PLAN). 50% OF THE SHRUBS (EXCEPT ON SLOPES 3:1 OR STEEPER) SHALL BE A MINIMUM FIVE (5) GALLON SIZE. WOODY SHRUBS SHALL BE PLANTED OVER HERBACEOUS GROUND COVER AREAS TO COVER 60% OF THE GROUND COVER AREA (AT MATURE SIZE). SPACING OF PLANTS SHALL ALLOW FOR THEIR SIZE AT MATURITY . ROOT BARRIERS: ROOT BARRIERS SHALL BE INSTALLED AT ALL TREES THAT ARE WITHIN FIVE (5) FEET OF PAVEMENT. LANDSCAPE MAINTENANCE RESPONSIBILITY: ALL LANDSCAPE AREAS ARE TO BE MAINTAINED BY THE PRIVATE LAND OWNER. OTHER: ALL LANDSCAPE AREAS SHALL HAVE POSITIVE DRAINAGE (2% GRADE IN PLANTING AREAS) AWAY FROM ALL STRUCTURES AND TERMINATING IN AN APPROVED DRAINAGE SYSTEM. ALL UTIL HES ARE TO BE SCREENED. EXISTING LANDSCAPING DAMAGED DURING CONSTRUCTION SHALL BE REPLACED IN KIND. WUCOLS WATER NEED CATEGORIES: PLANT LEGEND H = HIGH L = LOW M = MODERATE VL = VERY LOW W.E.L.O, HYDROZONE - (WUCOLS REGION 3) SYMBOL ABBREV. ! BOTANICAL NAME COMMON NAME SIZE QUANTITY NOTES I SHRUBS: ® DIE GRA DIETES GRANDIFLORA 'VARIEGATA' VARIEGATED FORTNIGHT LILY . 5 GAL 25 L 0 LAU NOB lAURUS NOBILJS SWEET BAY LAUREL 15 GAL 24 FOLIAGE FULL TO GROUND L ! 0 MYR COM i MYRTUS COMMUNIS TRUE MYRTLE 5 GAL i 40 L ' ' ! 0 ROS OFF i ROSMARINUS omCINAIJS 'PROSTRATUS' CREEPING ROSEMARY 1 GAL I 54 24" ON. CENTER SPACING L ' 0 i SAL LEU ' SALVIA lEUCANTHA MEXICAN BUSH SAGE 5 GAL 10 L GROUNDCOVERS: ~ SALVAfsE & ARC HYB ARCTOTIS HYBRIDS AFRICAN DAISY REPLANT 85 SF 12" ON CENTER SPACING L EXISllNG -I I MYO PAR MYOPORUM PARVIFOLJUM 'PINK' I PINK CREEPING MYOPORUM FlAlS 195 SF 12" ON CENTER SPACING L CDP 2019-0027 4 DE~IGN architecture ■ planning Kennith L Chriss A.I.A. r-wApel landscape architects inc I'- N 0 0 I 0) ..... 0 N a.. 0 0 -E ,._ (D a.. -C (D E 0. 0 Q) > (D 0 rn -en rn 0 0 571-B Hygeia Avenue Leucadia, CA 92024 (760) 943-0760 rwapel2@cox.net CA license #2825 (9 z Cl) -0 0 ...J ...J -w ::::, -LL co 0:: ~ w 0 s 0 0 0:: ...J I-LL Cl) w w 0:: I I-s +-' UJ ro z Project # Drawn by Scale As shown Date November 06, 2019 co 0 0 N 0) <( 0 "O rn ..c en ,:: rn () -Q) t::: 0 z (D 0 0 (D en rn a.. --s;t" 0 I'-~ CONCEPTUAL LANDSCAPE PLAN SHEET L-1 = ~ ffi "' 0 = ~ "' "' = = = < ~ ~ .., w = ~ ,5 = < = 1;l = 5i' ~ = 0 F' ~ F' = < ~ = = < -= t;J = 8 I -= 0 i" "' "' = "' < = = ~ = = < 5 F' < = = e .. ~ i" ~ 0 w ~ = d w cc F' i5 "' -~ = ~ 0 w cc '3 w ~ ~ w i" = 0 w ~ = = e = w = > 0 = ~ ~ u 5 = w ~ ~ 0 -= w = = f'= ~ "' "' "' = 0 I= < = = 0: "' 0 "' "' = "' < = = ~ ,;, 0 = z = :5 ~ .. w = ea u "" "' u = < = 1;l w si' ~ 0 ;,:: = = ~ 0 = ~ w = -w = < ~ = 0 ,= < f'= ~ 3 =" I" = "' I" ~ w u 5 u = = ~ w 0 ~ < = G ~ ,5 = < ci w = ;;'; = ~ = 0 ,= < = = e "' w i" = = < = 1 = ~ = = ~ ,;, WATER CONSERVATION NOTES: The project has been designed to incorporate the following water efficient landscape measures: • Planning and Design: All proposed plants have low water use requirements and have been selected to provide an aesthetically pleasing landscape that integrates into the existing plant palette of the surrounding landscape. Manufactured slopes will be planted with low water use plarit species to ensure effective erosion control consistent with Carlsbad Landscape Manual standards. Hedges are proposed to soften and screen the new building from the parking lot. • Soil analysis and preparation: Soil testing will be performed throughout the site and soils amended according to soil report recommendations. Organic compost will be incorporated into the soil to improve moisture holding capacity and improve soil texture and fertility. • Appropriate Plant Selection: The proposed plant palette is composed of low water using species (as defined by WUCOLS). Plants are selected with consideration of their mature sizes to reduce pruning and maintenance, as well as their suitability to soil type and site specific microclimates. Plants with similar water requirements are grouped together into "hydrozones" thereby promoting efficient use of irrigation water. Turf grass is not proposed for use in the project due to ifs high water needs. • Efficient irrigation: The existing site is irrigated with potable water. New irrigation systems will be installed using water efficient "drip line" technology and shall comply wrth the City of Carlsbad's Landscape Manual and Water Efficient Landscape Ordinance. The system will be operated by an automatic controller that uses evapotranspiration and/or soil moisture sensor data to schedule irrigation and will utllize a rain sensor to suspend irrigation during times of sufficient rainfall. PROPOSED NEY'i RESTROOM BUILDING L• I • 4 \ \\ \ .~ + 86.6 '\ \\ PROJECT \ \ LANDSCAPE AREA ;✓) ' I I ! + /'37.3 I /2 ' -:- !"'/ . >'\) EXl5TIN6 PARKIN6 I ( ' ~ • I I • Use of Mulches: A minimum 3 inch deep layer of organic mulch will be applied to landscape planting areas to promote retention of soil moisture as well as reduce weeds. • Appropriate Maintenance: The project will be maintained by trained professional landscape maintenance staff at the Flower Fields who have experience with the specific conditions and challenges of the site and with excellent knowledge of how to manage horticultural problems that may occur. The landscape will receive maintenance on a continual basis allowing for quick resolution of irrigation system problems, further reducing water waste. The use of organic fertilizers and composting will be encouraged to improve soil texture. Mulch shall be replaced as it decomposes. Trees and shrubs will receive occasional pruning to remove dead stems, promote blooming, and control size. Irrigation systems will be regularly inspected, maintained and adjusted to ensure proper coverage and plant health and to prevent overspray and water waste. + 96.8 . ·. . -. -.. -. . . . . . l 009 sf . -.. .·.J -. : . •. . i ' f.• . ' . ,. .. :::). ·.·.· 1· .. ·_ c;'.---. . .. I ... · . . -k ·. '•' . . "\. . '. .,-·· . ."\1·· .,,. .. ,t, . . ' . ,. \" ·. \"·,· ·. ":2< 1····• ... f\i···· . \: . 'i.i<. ~-~ r,- ·,·. \\ ; -. :.: _,. " \ \ \ \ \ \ 0 \ \ \ \ \ \ 5' . .. .-:: .... . ·.· .. \ \ \ \ \ \ \ \ \ \ EXl5TIN6 \ 6REENHOU5E \ \ \ \ \ \ \ 10' 20' \ \ N CONCEPTUAL WATER CONSERVATION PLAN SCALE 1"=10' EB , Q \ \ \ I I \ \ ' I I I \ / \ \ I 322sr . . . -,_ I \ HYDROZONELEGEND SYMBOL DESCRIPTION AREA (S.F)* PERCENTAGE* ' LOW WATER USE PLANTS 1,331 SF 100% (LWZONE PER WUCOLS) * WITHIN PROJECT LIMIT OF WORK SCALE 1"=1 O' 0 5' 10' 20' 2 HYDROZONE DIAGRAM ~-- SYMBOL LEGEND DESCRIPTION AREA OF RECYCLED WATER IRRIGATION AREA OF POTABLE WATER IRRIGATION IRRIGATION METHOD DESIGNATIONS: 0 DRIP LINE * WITHIN PROJECT LIMIT OF WORK AREA (S.F)* PERCENTAGE* 0 0% 1,331 SF 100% N EB CDP 2019-0027 4 DE8IGN architecture• planning Kennith L. Chriss A.I.A. r•wApel landscape architects inc t-- N 0 0 I 0) ,.... 0 N CL 0 (.) --E .... Q) CL --c: Q) E c.. 0 Q) > Q) 0 co --I/) co 0 (.) 571-B Hygeia Avenue Leucadia, CA 92024 (760) 943-0760 rwapel2@cox.net CA license #2825 (.9 z Cf) -o 0 _J ~ w ~ u: ~~ g~ ~o I-_J Cf) LL UJ w ~I s~ UJ co z Project # Drawn by Scale As shown Date November 06, 2019 co 0 0 N 0) ~ (.) -0 co .n 1/) .... co (.) -~ 0 z Q) 0 0 Q) 1/) co CL 3 t-- 1.() CONCEPTUAL WATER CONSERVATION PLAN SHEET L-2