GENERAL NOTES
1. These general notes shall apply to all work and all drawings in this set and shall
extend to any changes or additions agreed to during the course of work.
2. The GENERAL CONTRACTOR shall inspect the premises prior to commencing work to
familiarize him/herself with the conditions under which work will be performed.
3. a. The GENERAL CONTRACTOR is responsible for checking drawing documents and
dimensions and existing field conditions to confirm that the work is buildable as
shown. prior to proceeding with demolition and/or construction. All written
dimensions take precedence over scaled dimensions.
b. The GENERAL CONTRACTOR shall report to GREG COLEMAN DESIGNS, in writing,
any existing conditions or questions that require corrections, changes, adjustments or
replacement, in any and/or all, but not limited to the installation of mechanicaL
telephone, electricaL lighting, plumbing, ceiling. sprinklers, fire safety equipment,
walls, and defects found in existing base building (to include all piping, duct work
and conduit}. Any and all correction work shall be included as part of the
construction costs to be submitted. The GENERAL CONTRACTOR is responsible for
obtaining written clarification of the work in question from GREG COLEMAN DESIGNS
before proceeding with construction.
c. There has been no study performed, nor requested, as to the structural integrity of
the building itself, or parts thereof. The GENERAL CONTRACTOR is responsible for
having all drawings concepts and existing installations reviewed regarding such work
as necessary to insure the structural and engineering integrity of the premises and
any of the design concepts contained herein.
4. This project, all work, including materials and workmanship, shall conform to the
requirements of local, state, and federal codes, Jaws, ordinances, to include; 2013
CALIFORNIA RESIDENTIAL CODE (BASED ON 20121RC), 2013 CALIFORNIA BUILDING
CODE (BASED ON 20121BC). THE 2013 CALIFORNIA ELECTRICAL CODE (BASED ON THE
201 I NEC), THE 2013 CALIFORNIA PLUMBING CODE (BASED ON THE 2012 UPC BY
IAPMO), THE 2013 CALIFORNIA MECHANICAL CODE (BASED ON THE 2012 UPC BY
IAPMO), THE 2013 CALIFORNIA GREEN BUILDING CODE AND THE 2013 CALIFORNIA
FIRE CODE (BASED ON THE 2012 IFC). REFERENCE THE APPROPRIATE CODES ON THE
PLANS.
5. The GENERAL CONTRACTOR and subcontractors shall maintain Certifications of
Insurance for workman's compensation, public liability, and property damage for
limits as required by law. The GENERAL CONTRACTOR shall be responsible for
initiating, maintaining, and supervising all safety precautions with the work.
6. The area of work and existing buildings including elevators, lobby, and public
corridors shall be protected from damage. The GENERAL CONTRACTOR and
subcontractors shall provide protection for existing and new areas of work. Any
damage due to this work shall be repaired, replaced. or patched.
7. All work shall be erected and installed plumb, level, square and true. and in proper
alignment.
8. Manufactured materials and equipment shall be installed in accordance with the
manufacturer's recommendations and instructions.
9. The tenant spaces and facilities must be accessible to and functional for the
disabled.
10. Building occupant shall secure permits required by the Fire Department from the Fire
Prevention Bureau prior to occupying this building.
STORM WATER QUALITY NOTES
AND CONSTRUCTION BMP'S
This project shall comply with all requirements of the state permit; California
Regional Water Control Board. San Diego region. order No. 2001.01 NPDES No.
CASOJ0875.
{http://www .swrcs .ca.gov /rvvqcb9/programs/sd_stormwater .html)
Notes 1-6 below represent key minimum requirements for construction BMP'S.
1. Sufficient BMP'S must be installed to prevent silt, mud, or other construction debris
from being tracked into the adjacent street(s) or storm water conveyance systems
due to construction vehicles or any other construction activity. The contractor
shall be responsible for cleaning any such debris that may be in the street at the
end of each work day or after a storm event that causes a breech in the installed
construction BMP'S.
2.
3.
AU stock piles of uncompacted soil and/or building materials that are intended to
be left unprotected for a period greater than seven calendar days are to be
provided with erosion and sediment controls. Such soil must be protected each
day when the probability of rain is 40% or greater.
A concrete washout shall be provided on all projects which propose the
construction of any concrete improvements that are to be poured in place on the
4. site.
5. All erosion/sediment control devices shall be maintained in working order at all
times.
6. All slopes that are created or disturbed by construction activity must be protected
against erosion and sediment transport at all times.
The storage of all construction materials and equipment must be protected
against any potential release of pollutants into the environment.
---·----
4 3 2
6350 YARROW DRIVE
CARLSBAD, CA 92011
FIRE SAFETY & PREVENTION NOTES
I. The GENERAL CONTRACTOR complete plans and specifications for fire alarm
systems; fire extinguishing systems, including automatic sprinklers and other fire-
protection systems shall be submitted to Fire and Life Safety for review and approval
prior to installation. (CFC Sec. 901 .2)
2. Building owner or representative shall secure permits required by the Fire Department
from the Fire Prevention Bureau prior to occupying this building
3. Fire damper assemblies, including sleeves and installation procedures, shall be
approved by the Building Inspector prior to installation_
4. Separate plans for all fixed and mobile fire protection equipment, and all fire alarm
systems shall be submitted to the local Fire Marshall for approval prior to installation.
5. At least one fire extinguisher with a minimum rating of 2A lOBC shall be provided
within 75' maximum travel distance for each 6,000 square feet or portion thereof on
each floor. (CFC Sec. 906)
6. Complete plans and specifications for fire-extinguisher systems, including automatic
sprinklers and wet and dry sandpipes; halon systems and other special types of
automatic fire extinguishing systems; basement pipe inlets; and other fire-protection
systems and appurtenances thereof shall be submitted to Fire and Life Safety for
review and approval prior to installation. (CFC 901.2)
7. Buildings undergoing construction, alteration and demolition shall be in accordance
with CFC Chapter 14 (CFC 1401.1)
8. Address shall be provided for all new and existing buildings in a position as to be
plainly visible and legible from the street or road fronting the property. (CFC 505.1.)
9_ Decorative materials shall be maintained in a flame retardant condition (Title 19, Sec
3.08, 3.2 I; CFC 804, 806, 807)
10. Installation of fire alarm systems shall be in accordance with CFC 907.
11. Complete plans and specifications for fire alarms systems shall be submitted to Fire
and Life Safety for review and approval prior to installation {CFC 907.1.1)
12. An approved audible sprinkler flow alarm system shall be provided on the exterior of
the building in an approved location. (CFC 903.4.2)
13. All interior openings in 1-hour corridors (doors and frames) are to have 20-minute fire
rated assemblies with self-closers. Doors which require to be left open must have
automatic closures activated by smoke detectors. Door openings shall be protected
with a tight fitting smoke-and-draft control assembly having a fire protection rating
of not Jess than twenty minutes.
14. Exit signs must be internally or externally illuminated. Exit signs shall be illuminated at
all times and connected to an emergency power system in accordance to Section
(C.B.C. 10 I 1.2)
15. Fire extinguishing systems shall be installed in accordance with CFC 903 and comply
with standards of 903.3.
16. All valves controlling the water supply for automatic sprinkler systems and water-flow
switches on all sprinkler systems shall be electrically monitored where the number of
sprinklers is 20 or more. (CFC 903.4).
17. Complete plans and specifications for all fire extinguishing systems including
automatic sprinkler and standpipe systems and other special fire extinguishing
systems and related appurtenances shall be submitted to the City of San Diego for
review and approval prior to installation_
ADDITIONAL NOTES
1. Existing fire alarm and sprinkler system permitted and approved per the original
construction documents.
2. The automatic fire sprinkler system shall conform to the requirements of the 2013
Edition of the National Rre Protection Association Standard# 13.
3. Installation of the Fire sprinkler system shall not be started until complete plans and
specifications (including water supply information and type of existing system, if any)
have been approved by Carlsbad Rre Department_
4. At various stages and upon competition, the system shall be tested in the presence
of the Carlsbad Fire Department.
5. Construction documents approved by the tire code official are approved with the
intent that such construction documents comply in all respects with current code.
Review and approval by the fire code official shall not relieve the applicant of the
responsibility of compliance with this code.
6. It is understood that plans for the project have, at this time, been reviewed for
compliance with all applicable State and City Regulations, and that the project as
a whole has been approved by the City, with the exception of any deferred items
that may be listed.
7. 1/We understand that 1/We will not be authorized any inspection of the deferred
items proposed prior to the submittal and approval of plans and/or calculations for
those deferred items.
8. If required, Complete plans and specifications for all fire extinguishing systems,
including automatic sprinkler and standpipe systems and other special fire
extinguishing systems and related appurtenances shall be submitted to the City of
Carlsbad for review and approval prior to installation. CFC901.2
9 _ If required, complete plans and specifications for fire alarm systems shall be
submitted to the City of Carlsbad Developmental Services for review and approval
prior to installation. CFC 907. I. I
CAL GREEN REQUIREMENTS
BELOW ARE SUMMZRIZED STANDARDS FROM 2010 EDITION OF CALIFORNIA GREEN
BUILDING STANDARDS CODE. REFER TO THIS MANUAL FOR ADDITIONAL INFORMATION
AND REQUIREMENTS, INCLUDING BUT NOT LIMITED TO, REFERENCE CHARTS AND MORE
SPECIFICS REGARDING REQUIREMENTS TO BE MET.
DIVISION 5.1 -PlANNING AND DESIGN
5.106.4 BICYCLE PARKING
COMPLY WITH SECTIONS 5. I 06.4. I AND 5. 106.4.2; OR MEET LOCAL
ORDINANCE OR THE UNIVERSITY
OF CALIFORNIA POLICY ON SUSTAINABLE PRACTICES, WHICHEVER IS
STRICTER
5. I 06.8 LIGHT POLLUTION REDUCTION
COMPLY WITH LIGHTING POWER REQUIREMENTS IN THE CALIFORNIA ENERGY
CODE, CCR, PART 6, AND DESIGN INTERIOR AND EXTERIOR LIGHITNG SUCH
THAT ZERO DIRECT-BEAM ILLUMINATION LEAVES THE BUILDING SITE.
DIVISION 5.2 -ENERGY EFFICIENCY
5.201 GENERAL
IT IS THE INTENT OF THIS CODE TO ENCOURAGE BUILDING TO ACHIEVE
EXEMPLARY PERFORMANCE IN THE AREA OF ENERGY EFFICIENCY
STANDARDS .... GREEN BUILDING SHOULD ACHIEVE AT LEAST A 15 PERCENT
REDUCTION IN ENERGY USAGE WHEN COMPARED TO THE STATE'S
MANDATORY ENERGY EFFICIENCY STANDARDS
DIVISION 5.3-WAJER EFFICIENY AND CONSERVATION
5.303.2 TWENTY PERCENT SAVINGS
A SCHEDULE OF PLUMBING FIXTURES AND FIXTURE FITTINGS THAT WILL REDUCE
THE OVERALL USE OF POTABLE WATER WITHIN THE BUILDING BY 20 PERCENT
SHALL BE PROVIDED.
5.303.4 WASTE WATER REDUCTION
EACH BUILDING SHALL REDUCE BY 20 PERCENT WASTEWATER BY ONE OF THE
FOLLOWING METHODS: INSTALL WATER-CONSERVING FIXTURES OR UTILIZING
NON POTABLE WATER SYSTEMS
5.303.6 PLUMBING FIXTURES AND FITTINGS
PLUMBING FIXTURES AND FITTINGS SHALL MEET THE STANDARDS REFERENCED
IN TABLE 5.503.6
DIVISION 5.4-MAJERIAL CONSERVATION AND RESOURCE EFFICIENCY
5.407. I WEATHER PROTECTION
PROVIDE A WEATHER-RESISTANT EXTERIOR WALL AND FOUNDATION
ENVELOPEAS REQUIRED BY CALIFORNIA BUILDING CODE SECTION 1403.2
(WEATHER PROTECTION) AND CALIFORNIA ENERGY CODE SECTION I 50,
(MANDATORY FEATURES AND DEVICES), MANUFACTURERS' INSTALLATION
INSTRUCTIONS OR LOCAL ORDINANCE, WHICHEVER IS MORE STRINGENT.
5.407.2 MOISTURE CONTROL
5.407.2.2 ENTRIES AND OPENINGS
DESIGN EXTERIOR ENTRIES AND/OR OPENINGS SUBJECT TO FOOT
TRAFFIC OR WIND-DRIVEN RAIN TO PREVENT WATER INTRUSION INTO
BUILDINGS.
5.408. I CONSTRUCTION WASTE DIVERSION
ESTABLISH AND CONSTRUCTION WASTE AND MANAGEMENT PLAN FOR THE
DIVIRTED MATERIALS, OR MEET LOCAL CONSTRUCTION AND DEMOLITION
WASTE MANAGEMENT ORDINANCE, WHICHEVER IS MORE STRINGENT
5.408.2 CONSTRUCTION WASTE MANAGEMENT PLAN
WHERE A LOCAL JURISDICTION DOES NOT HAVE A CONSTRUCTION AND
DEMOLITION WASTE MANAGEMENT ORDINANCE, SUBMIT A CONSTRUCTION
WASTE MANAGEMENT PLAN FOR APPROVAL BY THE ENFORCEMENT
AGENCY THAT MEETING CAL GREEN BUILDING STANDARDS CODE
PARAMETERS ITEMS 1-4.
5.408.2.1. DOCUMENTATION
DOCUMENTATION SHALL BE PROVIDED TO THE ENFORCING AGENCY WHICH
DEMONSTRATES COMPLIANCE WITH SECTION 5.408.2, ITEMS ITHRU 4.
5.408.3 CONSTRUCTION WASTE REDUCTION OF AT LEAST 50 PERCENT
RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 50 PERCENT OF THE
NON-HAZARDOUS CONSTRUCTION AND DEMOLITION DEBRIS, OR MEET
LOCAL CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT
ORDINANCE, WHICHEVER IS MORE STRINGENT.
5.410. I RECYCLING BY OCCUPANTS
PROVIDE READILY ACCESSIBLE AREAS THAT SERVE THE ENTIRE BUILDING AND
ARE IDENTIFIED FOR THE DEPOSITING, STORAGE AND COLLECTION OF NON-
HAZARDOUS MATERIALS FOR RECYCLING, INCLUDING AT A MINIMUM PAPER,
CORRAGATED CARDBOARD, GLASS, PLASTICS, AND METALS
5.4 10. 1.1 SAMPLE ORDINANCE
SPACE ALLOCATION FOR RECYCLING AREAS SHALL COMPLY WIHT CHAPTER
I 8, PART 3, DIVISION 30 OF THE PUBLIC RESOURCES CODE.
5.410.2.5 DOCUMENTATION
A BUILDING "SYSTEMS MANUAL" AS LISTED IN CGC SECTION 5.410.2.5 SHALL BE
DELIVERED TO THE BUILDING OWNER OR REPRESENTATIVE AND THE FACILITIES
OPERATOR. THE "SYSTEMS MANUAL" SHALL CONTAIN THE REQUIRED FEATURES
LISTED IN CGC SECTION 5.4 10.2.5. I.
DIVISION 5.5-ENVIRONMENTAL QUAUTY
5.504.3 COVERING OF DUCT OPENINGS AND PROTECTION OF MECHANICAL
EQUIPMENT DURING CONSTRUCTION
AT TIME OF ROUGH INSTALLATION, OR DURING STORAGE ON THE
CONSTRUCTION SITE AND UNTIL FINAL STARTUP OF THE HEATING AND
COOLING EQUIPMENT. ALL DUCT AND OTHER RELATED AIR DISTRIBUTION
COMPONENT OPENINGS SHALL BE COVERED WITH TAPE. PLASTIC. SHEET
METAL OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY TO
REDUCE THE AMOUNT OF DUST AND DEBRIS WHICH MAY COLLECT IN THE
SYSTEM.
5.504.4 FINISH MATERILA POLLUTANT CONTROL
FINISH MATERIALS SHALL COMPLY WITH SECTIONS 5.504.4. I THROUGH
5.504.4.4 OF CAL GREEN BUILDING CODE. THESE MATERIALS INCLUDE:
ADHESIVES, SEALANTS, AND CAULKS & PAINTS AND COATINGS, & CARPET
SYSTEMS.
5.504.4.5 COMPOSITE WOOD PRODUCTS
HARDWOOD PLYWOOD, PARTICLE BOARD AND MEDIUM DENSITY
FIBERBOARD COMPOSITE PRODUCTS USED ON THE INTERIOR OR EXTERIOR OF
THE BUILDING SHALL MEET THE REQUIREMENTS FOR FORMALDEHYDE AS
SPECIFIED IN ARB'S AIR TOXICS CONTROL MEASURE FOR COMPOSITE WOOD
(I 7 CCR 93120 ER SEQ.), BY OR BEFORE THE DATES SPECIFIED IN THOSE
SECTIONS, AS SHOWN IN TABLE 5.504.4.5
CAL GREEN REQUIREMENTS CONT.
5.504.4.5.2 DOCUMENTATION
VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED AS
REQUESTED BY THE ENFORCING AGENCY.
5.504.4.6 RESILIENT FLOORING SYSTEMS
FOR 50 PERCENT OF FLOOR AREA RECEIVING RESILIENT FLOORING, INSTALL
RESILIENT FLOORING COMPLING WITH VOC-EMISSION LIMITS DEFINED IN TEH
2009 COLLABORATIVE FOR HIHG PERFORMANCE SCHOOLS (CHPS) CRITERIA
AS LISTED ON ITS LOW-EMITTING MATERIALS LIST (OR PRODUCT REGISTRY) OR
CERTIFIED UNDER THE RESILIENT FLOOR COVERING INSTITUTE (RFCI) FLOOR
SCORE PROGRAM.
5.504.4.6. I VERIFICATION OF COMPLIANCE
DOCUMENTATION SHALL BE PROVIDED VERIFYING THAT RESILIENT FLOORING
MATERIALS MEET THE POLLUTANT EMISSION LIMTS.
5.504.5.3 FILTERS
IN MECHANICALLY VENTILATED BUILDtNGS, PROVIDE REGULARLY OCCUPIED
AREAS IN THE BUILDING WITH AIR FILTRATION MEDIA FOR OUTSIDE AND RETURN
AIR PRIOR TO OCCUPANCY THE PROVIDES AT LEAST A MINIMUM EFFICtENCY
REPORTING VALUE (MERV) OF 8
5.504.7 ENVIRONMENTAL TOBACCO SMOKE (ETS) CONTROL
WHERE OUTDOOR AREA ARE PROVIDED FOR SMOKING, PROHIBIT SMOKING
WITHIN 25 FEET OF BUILDING ENTRIES, OUTDOORS INTAKES, AND OPERABLE
WINDOWS IN BUILDINGS; OR AS ENFORCED BY ORDINANCES, REGULATIONS, OR
POLICIES OF ANY CITY, COUNTY, CITY AND COUNTY, CALIFORNIA COMMUNITY
COLLEGE, CAMPUS OF THE UNIVERSITY OF CALIFORNIA, WHICHEVER ARE MORE
STRINGENT.
5.505.1 INDOOR MOISTURE CONTROL
BUILDINGS SHALL MEET OR EXCEED THE PROVISIONS OF CALIFORNIA BUILDING
CODE, CCR, TITLE 24, PART 2, SECTIONS 1203 (VENTILATION) AND CHAPER 14
(EXTERIOR WALLS)
5.506. I OUTSIDE AIR DELIVERY
FOR MECHANICALLY OR NATURALLY VENTILATED SPACES IN BUILDINGS, MEET
THE MINIMUM REQUIREMENTS OF SECTION 121 (REQUIREMENTS FOR
VENTILATION) OF CALIFORNIA ENERGY CODE, CCR, TITLE 24, PART 6, OR THE
APPLICABLE LOCAL CODE, WHICHEVER IS MORE STRINGENT. AND CHAPTER 4 OF
CCR, TITLE 8.
5.506.2 CARBON DIOXIDE MONITORING
FOR BUILDING EQUIPPED WITH DEMAND CONTROL VENTILATION, C02 SENSORS
AND VENTILATION CONTROLS SHALL BE SPECIFIED AND INSTALLED IN
ACCORDANCE WITH THE REQUIREMENTS OF THE CURRENT EDITION OF THE
CALIFORNIA ENERGY CODE, CCR, TITLE 24, PART 6, SECTION 121 (C).
5.5073 ACOUSTICAL CONTROL
EMPLOY BUILDING ASSEMBLIES AND COMPONENTS WITH SOUND TRANSMISSION
COEFFICIENT (STC) VALUES DETERMINED IN ACCORDANCE WITH ASTM E 90 AND
ASTME413.
5.507.4. I EXTERIOR NOISE TRANSMISSION
WALL AND ROOF-CEILING ASSEMBLIES MAKING UP THE BUILDING ENVELOPE
SHALL HAVE AN STC OF AT LEAST 50, AND EXTERIOR WINDOWS SHALL HAVE A
MINUMUM STC OF 30 FOR ANY OF THE FOLLOWING LOCATIONS:
WITHIN 1.000 FT OF RIGHT OF WAYS OF FREEWAYS
WITHIN 5 MILES OF AIRPORTS SERVING MORE THAN 10,000 COMMERCIAL JETS
PER YEAR
WHERE SOUND LEVELS AT PROPERTY LINE REGULARLY EXCEED 65 DECIBELS,
OTHER THAN OCCASSIONAL SOUND DURE TO CHURCH BELLS, TRAIN HORNS,
EMERGENCY VEHICLES AND PUBLIC WARNING SYSTEMS.
5.507.4.21NTERIOR SOUND
WALL AND FLOOR-CEILING ASSEMBLIES SEPERATING TENANT SPACES AND
TENANT SPACES AND PUBLIC SPACES SHALL HAVE AN STC OF AT LEAST 40.
5.508.1.1 CHLOROFLUOROCARBONS (CFCs)
INSTALL HVAC, REFRIGERATION, AND FIRE SUPPRESSION EQUIPMENTTHAT DO
NOT CONTAINC CFCs.
5.508.1.2 HALONS
INSTALL HVAC, REFRIGERATION AND FIRESUPPRESStON EQUIPMENTTHAT DO
NOT CONTAIN HALONS.
PROJECT SUMMARY
SITE ADDRESS:
SQUARE FOOTAGE:
OCCUPANCY TYPE:
ZONING:
CONSTRUCTION TYPE:
BUILDING STORIES:
AREA OF IMPROVEMENT:
A.P.N.:
LEGAL DESCRIPTION:
SCOPE OF WORK:
WATER DISTRICT:
SEWER DISTRICT:
SCHOOL DISTRICT:
DEFERRED SUBMITTALS:
6350 YARROW DRIVE
CARLSBAD, CA 9201 I
9,925
A-2 I F-2 I S-2
P-M
TYPE I liB-SPRINKLERED
CENTRAL BAY OF THE EXISTING CONCRETE BUILDING
2 I 3-050-0600
Lot I I. Map 8054
TENANT IMPROVEMENT WORK FOR A BREWERY,
TASTING ROOM AND OFFICES. THE AREA OF
IMPROVEMENT CONTAINS EXISTING ADA COMPLIANT
TOILET FACILITIES.
CARLSBAD MUNICIPAL WATER DISTRICT
CITY OF CARLSBAD WASTE WATER DIVISION
CARLSBAD UNIFIED SCHOOL DISTRICT
FIRE SPRINKLER SYSTEM 2013 CFC 903 AND 2013 NFPA
13.
FIRE ALARM SYSTEM 2013 CFC 907 INCLUDING CFC
907.2 SECTIONS APPLICABLE TO OCCUPANCY GROUPS,
AND 2013 NFPA 72.
-----------
SHEET iNDEX
TITLE SHEET
T-1.0 TITLE SHEET
GENERAL INFORMATION
G-1.0
G-1.1
G-1.2
G-1.3
GENERAL PROJECT INFORMATION
GENERAL PROJECT INFORMATION
EGRESS PLAN
PARKING CALCULATION PLAN
ARCHITECTURAL
A-I .0 SITE PLAN I SYMBOL LEGEND
A-I. I EXISTING I DEMOLITION PLAN
A-1.2 PROPOSED FLOOR PLAN
/ · 'F C.'"''"<LSBAO J~,'""-_, ~:\~:!\JG COf•/i\:l!SSiON
'C.:~------
:.•. "o:====;;;,;D::;:at;::::e:===:J
CITY OF CARLSBAD
PLANNING COMMISSION
Case Name: .46:;-fr=.-b /K W4s
Case No,: CUf/6-() :S
A-I .3 REFLECTED CEILING PLAN-EXISTING I DEMO
A-1.4 ELEVATIONS I ENLARGED FLOOR PLANS
STRUCTURAL
Sl GENERAL NOTES /TANK LAYOUT
PLUMBING
PI PLUMBii'iG DETAILS
P2 PLUMBING WASTE AND VENT PLAN
P3 PLUMBING WATER AND GAS PLAN
P4 PLUMBING SCHEMATICS
ELECTRICAL
El .0 ELECTRICAL LIGHTING PLAN
E2.0 ELECTRICAL POWER PLAN
E3.0 ELECTRICAL SCHEDULES
E4.0 ELECTRICAL SCHEDULES
E5.0 ELECTRICAL TITLE-24 FORMS
E6.0 ELECTRICAL TITLE-24 FORMS
8/1/2016 10:56:19 PM
ABSTRACT
ALE WORKS
6350 Yarrow Drive
Carlsbad, Ca 92011
CLIENT
Abstract Ale Works
6350 Yarrow Drive
Carlsbad, CA 920 I I
ARCHITECT
Greg Coleman Designs
3587 Herman Ave
San Diego, CA 92104
(805)746-651 6
STRUCTURAL
HTK Structural Engineers, LLP
I 4288 Danielson Street Suite #200
Poway, Ca 92064
(858) 679-8989
ELECTRICAL
NEDC, Inc.
3103 Falcon Street Suite J
San Diego, Ca 92 I 03
(619)278-0076
PLUMBING
Zoller Plumbing, Inc.
10757 Oak Creek Drive
Lakeside, Ca 92040
(6 I 9) 443-1009
CURRENT DRAWING SET
Description
City Re-Submittal 3
CURRENT REVISION
Number Description
City Re-Submittal
Sheet Issue Date Scale
08/02/16
GCD Projecl Number
1605
TITLE SHEET
T-1.0
Issue Date
08/02!16
Issue Date
07/15/16
INTERNATIONAL SYMBOL OF ACCESSN.T.S.1CALIFORNIA GRADE 2 BRAILLEN.T.S.2TYPESTYLE EXAMPLESN.T.S.3RESTROOM SIGNAGE1/2" = 1'-0"4RESTROOM DOOR SIGNAGEN.T.S.5DIRECTIONAL SIGNAGEN.T.S.6ROOM IDENTIFICATION SIGNN.T.S.7RESTROOM SIGNAGEN.T.S.8TACTILE EXIT SIGNAGEN.T.S.9MAX OCCUPANCY SIGNAGEN.T.S.10ACCESIBILITY SIGNAGE GRAPHICN.T.S.11BACKGROUND: COLOR CLEARPICTOGRAM: COLOR WHITEREFER TO A5.0 FOR LOCATIONSELF ADHESIVE LABELNOTE:WHEN MOUNTING DIRECTLY ON GLAZING, INSTALL 1 SIGN ON EACH SIDE OF GLAZING, BACK-TO-BACK.I O XWALL SURFACEACRYLIC PERSPECIFICATIONMOUNTING:FOAM TAPE ANDSILICONECIRCULAR SIGN:ACRYLIC WITH EASEDEDGESENGRAVED PICTOGRAM:SIGNAGE COLOR #2BACKGROUND:SIGNAGE COLOR #1UNISEX RESTROOMNOTES:1. REFER TO 4/A730 FOR MOUNTING LOCATION AND HEIGHTRESTROOM DOOR SIGNAGE, REFER TO 05/A771RESTROOM TACTILEIDENTIFICATIONSIGNAGE ON LATCHSIDE OF DOOR.REFER TO 08/A771DOOR AND FRAME:REFER TO DOORSCHEDULECLEAR BRAILLE CELLS:REFER TO CBC 1117B.5.6ROUNDED BRAILLE DOTEXAMPLES OF TYPESTYLE FOR TACTILE AND VISUAL CHARACTERS ON ACCESSIBILITY SIGNAGE. CHARACTERS SHOWN 1" HIGH. REFER TO SIGNAGE DETAILS FOR CHARACTER HEIGHTS.INT'L SYMBOL OF ACCESSEQ EQ3' - 0"3" 2' - 6" 3"3' - 0"INCH1/400.20"BTWN CELLSDOTS @0.10" O.C.DOTS @0.10" O.C.60"EQ EQ4"MOUNTING DETAILUNAUTHORIZED VEHICLESPARKED IN DESIGNATEDACCESSIBLE SPACES NOTDISPLAYING DISTINGUISHINGPLACARDS OR LICENSEPLATES ISSUED FORPERSONS WITH DISABILITIESMAY BE TOWED WAY ATOWNER'S EXPENSETOWED VEHICLES MAY BE CLAIMEDAT:__________________________BY ORDER OF:_________________6' - 8" MIN.PASSENGER LOADING ZONES SHALL PROVIDE AN ACCESS AISLE AT LEAST 60 IN WIDE AND 20 FT LONG ADJACENT AND PARALLET TO THE VEHICLE PULL-UP SPACE.VANACCESSIBLEPARKING ONLYMINIMUM FINE $250BRAILLE(REFER TO 2/A-771a)RAISED COPY:1/32" RAISED MACHINE-CUT TEXT.TYPEFACE: OPTIMA REGULAR.COLOR: SIGNAGE COLOR #2ENGRAVED PICTOGRAMS:SIGNAGE COLOR #2REFER TO 4/- FORMOUNTING HEIGHTWALL SURFACE1/4" THICK ENGRAVEABLEACRYLIC WITH 18 GA.ALUMINUM BACKERMOUNTING: FOAM TAPE AND SILICONEBACKGROUND:SIGNAGE COLOR #1℄OF SIGN: +60" A.F.F.WALL SURFACEBACKGROUND:SIGNAGE COLOR #4BRAILLE(REFER TO 2/A-771a)RAISED COPY:1/32" RAISED MACHINE-CUT TEXT. TYPEFACE: OPTIMA REGULAR.COLOR: SIGNAGE COLOR #1.1/4" THICK ACRYLICWITH 18 GA. ALUMINUM BACKERMOUNTING: FOAM TAPE AND SILICONENOTE: • MOUNT EDGE OF SIGN 4" OFF ADJACENT WALL OR DOOR U.O.N. ON INTERIOR ELEVATION SHEETS.• QUANTITY AND LOCATION PER ARCHITECTURAL SHEET G005WALL SURFACERAISED COPY:1/32" RAISED MACHINE-CUT TEXT.TYPEFACE: OPTIMA REGULARCOLOR: SIGNAGE COLOR #1.CENTER TEXT ON SIGN;VERIFY OCCUPANT CAPACITY1/4" THICK ACRYLICWITH 18 GA.ALUMINUM BACKERMOUNTING:FOAM TAPE AND SILICONEBACKGROUND: SIGNAGE COLOR #4℄OF SIGN:+60" A.F.F.MAXIMUM195OCCUPANCYOF SIGN: +60" A.F.F.MOUNTING POLE1/4" THICK ACRYLIC WITH 18 GA. ALUMINUM BACKERMOUNTING: STRAP TO MOUNT BACK TO BACK SIGNSBACKGROUND:SIGNAGE COLOR #1PICTOGRAM:SIGNAGE COLOR #2DIRECTIONAL ARROW:SIGNAGE COLOR #2ARROW DIRECTION AS REQUIRED TO POINT TOWARDS RAMP.UNISEX ROOMEXITMOUNTING DETAIL1/2".1/2".3/8".3/4".1/4".6".1/2".MOUNTING DETAILMOUNTING DETAILMOUNTING DETAIL1/2".1/2".3/8".3/4".1/2".8-7/8".1/2".8".1/2".9".1/2".7".7 1/2".EQEQ4".1/2".3/4".3/8".3/4".3/8".3/4".1/2".℄7".1/2".1 3/4".1 1/4".6".1/2".10".BACKGROUND:SIGNAGE COLOR #4BRAILLE(REFER TO 2/A-771a)RAISED COPY:1/32" RAISED MACHINE-CUT TEXT. TYPEFACE: OPTIMA REGULAR.COLOR: SIGNAGE COLOR #1.12341/2".1/2".3/8".3/4".1/2".2".6".*TYPICAL FOR ALL DOORS ACCESSED FROM EXTERIOR CORRIDORS OR VESTIBULES.NOTE: • QUANTITY AND LOCATION PER ARCHITECTURAL SHEET G005NOTES: • ATTACH SIGN WITH SS SIGN CLAMPS• REFER TO CIVIL DRAWINGS FOR ADDITIONAL INFORMATIONVANACCESSIBLE
FFGGEE11HH33152' - 1"1984 SFBAR / TASTINGg/15 133436 SFOFFICEg/100 2MEN'S RRWOMEN'S RRHALL365 SFBOILER RMg/300 2719 SFCOLD STORAGEg/300 3STORAGE5585 SFBREWINGg/100 569999323851001009556(EXIT SEPERATION REQUIRED = 171' - 0" / 3 = 57' - 0") 152' - 1" PROVIDED171' - 0"MAX. EXIT ACCESS TRAVEL DISTANCE -173' - 0"31642231ELECEXITEXIT OCCUPANT LOADTOTAL EXIT OCCUPANT LOADXXRoom name150 SF g/15 10XXAREA LABEL:EXIT SIGN - 90 MINUTE BACK UP BATTERY MUST BE PROVIDED PER CBC 1006.3.INTERNATIONAL SYMBOL OF ACCESS1RESTROOM SIGNAGE2TACTILE EXIT SIGN3MAXIMUM OCCUPANCY SIGNAGE4TACTILE EXIT ROUTE SIGN5ROOM IDENTIFICATION SIGN6
FFGGEE11HH33MEN'S RRWOMEN'S RRHALLSTORAGEELEC5203 SF1/10005.2WAREHOUSE1570 SF2.5/1000 3.9MANUFACTURINGOFFICEBOILER RMCOLD STORAGEBAR / TASTINGBREWING1168 SF2.5/1000 2.9MANUFACTURING1984 SF2.5/1000 5.0BAR / TASTING
AREA OF T.I.1234567891011121314151617181920212223242526272830293132333435363738394041424344464748495051526061626372737471 70 69 6859 58 57 5664 65 66 67YARROW DRIVECAMINO VIDA ROBLEEXISTING BUILDINGEXISTING BUILDINGEXISTING DRIVEWAYEXISTING PARKING / DRIVEWAYEXISTING DRIVEWAYEXISTING PARKING / DRIVEWAYEXISTING PARKING / DRIVEWAYEXISTING PARKING / DRIVEWAYEXISTING DRIVEWAYEXISTING LANDSCAPINGEXISTING LANDSCAPINGOPEN AREAOPEN AREAEXISTING LANDSCAPING45PROPERTY LINEPROPERTY LINEPROPERTY LINE53 54 55+/- 33' - 0"CHILLER YARD1t1iA1011SIM101A10.0111111Room name1011/A1011A101SIM1A101SIM?A101NameElevationEXTERIOR ELEVATIONINTERIOR ELEVATIONBUILDING SECTIONWALL SECTIONDETAIL CALLOUTDATUM LINESPOT ELEVATIONSLAB STEPNORTH ARROWDOOR TAG(SEE DOOR SCHEDULE)WINDOW TAG(SEE WINDOW SCHEDULE)WALL / FLOOR / ROOF TAG(SEE WALL / FLOOR / ROOF ASSEMBLIES)REVISION TAGKEYNOTEROOM TAGCEILING TAGCeiling Finish1'-0" A.F.F.
FFGGEE11HH33ALIGNE1E2E3E4E5E624' - 0"24' - 0"24' - 0"160' - 0"EXISTING WALLSPROPOSED WALLSWALLS TO BE DEMOLISHEDCOLD STORAGE - SELF SUPPORTING UNIT
FDFDFDFSFSFSFSA-1.42A-1.41FFGGEE11HH33BAR / TASTING01OFFICE02MEN'S RR03REF A1.4WOMEN'S RR04REF A1.4HALL06BOILER RM05COLD STORAGE08STORAGE09BREWING07KEG WASHERGRAIN CRACKERPALETTES W/ KEGSE1E221E33E4E5E6SEE DRAWINGS FROM PREMIER STAINLESS SYSTEMS FOR BREWING EQUIPMENT LAYOUT14' - 9 1/2"17' - 6"5' - 0"5' - 6"36' - 8"10' - 2"5' - 0"20' - 0"20' - 2 1/2"5' - 0 1/2"1' - 8"2' - 0"EXISTING ELECTRICAL PANEL18' - 5"4' - 0"2' - 6"9' - 0"37' - 10"80' - 8"ADA HEIGHT COUNTERCHILLER8' - 6"BOILER19' - 10"LINEAR FLOOR DRAINMOP SINK24' - 0"24' - 0"24' - 0"160' - 0"48' - 0"48' - 0"31' - 11 1/2"EXISTING ELECTRICAL PANEL & TRANSFORMER2' - 6 1/2"EXISTING ELECTRICAL PANEL & TRANSFORMER TO BE RELOCATEDELEC104WATER STORAGE TANKBLOW DOWN TANKWATER HEATERLOCAL SLAB REPLACEMENT TO CREATE SLOPE AROUND DRAINLINEAR FLOOR DRAINLOCAL SLAB REPLACEMENT TO CREATE SLOPE AROUND DRAIN4' - 0"4' - 0"4' - 0"4' - 0"52' - 2"29' - 0"20' - 0"19' - 0"22' - 0"GATE36" HIGH RAILING10' - 0"16' - 0"EXISTING WALLSPROPOSED WALLSWALLS TO BE DEMOLISHEDCOLD STORAGE - SELF SUPPORTING UNIT
FFGGEE11HH33CEILING GRIDS SHOWN IN GRAY ARE TO BE DEMOLISHEDCEILING GRIDS SHOWN IN GRAY ARE TO BE DEMOLISHEDTYPE-B FLUE VENT FROM BOILER TO ROOFEXISTING WALLSPROPOSED WALLSWALLS TO BE DEMOLISHEDCOLD STORAGE - SELF SUPPORTING UNITRECESSED FLUORESCENT - 2X4RECESSED FLUORESCENT - 2X2FLUORESCENT PENDANT - 2X4FLUORESCENT PENDANT - 8 FTSURFACE MOUNTED FLUORESCENTRECESSED FLUORESCENT - TO BE DEMOLISHED