Loading...
HomeMy WebLinkAboutRP 16-01; VERIZON ARMY NAVY ATHLETIC FACILITY WCF; Planning Commission• ire ess OVERALL HEIGHT 81'-1" [81.1'] CARLSBAD STATE STREET 2600 CARLSBAD BOULEVARD CARLSBAD, CA 92008 VICINITY MAP THOMAS GUIDE PAGE: 1106 -D5 ADDRESS 2600 CARLSBAD BOULEVARD CARLSBAD, CA 92008 DIRECTIONS: {FROM vzw·s OFFICES IN IRVINE): HEAD SOUTH ON 1-5 TO THE CARLSBAD VILLAGE DRIVE EXIT; EXIT CARLSBAD VILLAGE DRIVE At~D HEAD WEST TO CARLSBAD BOULEVARD; TURN RIGHT ON CARLSBAD BOULEVARD AND HEAD NORTH TO BEECH AVENUE; TURN RIGHT ON BEECH AVENUE AND HEAD EAST. TURN INTO THE PARKING LOT ON YOUR LEFT HAND {NORTH) SIDE OF THE ROAD. SCALE THE DRAWING SCALES SHOWN IN THIS SET REPRESENT THE CORRECT SCALE ONLY WHEN THESE DRAWINGS ARE PRINTED IN A 24" x 36" FORMAT. IF THIS DRAWING SET IS NOT 24" x 36", THIS SET IS NOT TO SCALE. ALL DRAWINGS ARE SCHEMATIC. DO NOT SCALE DRAWINGS TO DETERMINE OR VERIFY ANY DIMENSIONS. DRAWINGS OF ANY SIZE SHALL NEVER BE SCALED FOR ANYTHING OTHER THAN GENERAL REFERENCE. ---------~------ CONSUL TANT TEAM ARCHITECT: BOOTH & SUAREZ ARCHITECTURE, INC. 325 CARLSBAD VILLAGE DRIVE, SUITE D2 CARLSBAD, CA 92008 (760) 434-8474 {760) 434-8596 (FAX) SURVEYOR: FLOYD SURVEYING 28936 OLD TOWN FRONT ST, SUITE 203 TEMECULA, CA 92590 (951) 964-8647 LEASING/PLANNING: PLANCOM, INC. RODNEY PHILHOWER .302 STATE PLACE ESCONDIDO, CA 92029 {619) 200-2260 PERMITS REQUIRED • CONDITIONAL USE PERMIT PROJECT SUMMARY APPLICANT: OWNER: VERIZON WIRELESS 15505 SAND CANYON AVENUE IRVINE, CA 92618 CONTACT: RODNEY PHILHOWER PHONE: (619) 200-2260 ARMY AND NAVY ACADEMY 2605 CARLSBAD BOULEVARD CARLSBAD, CA 92008 SITE CONTACT: COLONEL LAWRENCE SAUL UNITED STATES ARMY (RETIRED) PHONE: (760) 547-5197 PROJECT DESCRIPTION: • INSTALLATION OF ONE (1) VERIZON WIRELESS TELECOMMUNICATIONS EQUIPMENT CABINET INSIDE A NEW CHAIN LINK FENCE EQUIPMENT ENCLOSURE AT GRADE • INSTALLATION OF A 15kW ENCLOSED STANDBY GENERATOR WITH A 54 GALLON DIESEL TANK ON A CONCRETE PAD INSIDE PROPOSED EQUIPMENT ENCLOSURE AT GRADE • REPLACE EXISTING 81 '-1" HIGH LIGHT STANDARD WITH A NEW 81'-1' HIGH LIGHT STANDARD, RELOCATE EXISTING LIGHT FIXTURES AND BALLAST BOXES FROM EXISTING LIGHT STANDARD TO NEW LIGHT STANDARD • INSTALLATION OF THREE (3) VERIZON WIRELESS ANTENNA SECTORS, OF TWO (2) ANTENNAS EACH {TOTAL OF SIX (6) ANTENNAS) MOUNTED ON PROPOSED 81 '-1" HIGH LIGHT STANDARD • INSTALLATION OF TWO (2) VERIZON WIRELESS RRU UNITS PER SECTOR <TOTAL OF SIX {6) RRU'S) MOUNTED ON PROPOSED 81 -1" HIGH LIGHT STANDARD • INSTALLATION OF TWO (2) VERIZON WIRELESS RAYCAP DC SURGE PROTECTION UNITS MOUNTED ON PROPOSED 81'-1" HIGH LIGHT STANDARD • INSTALLATION OF ONE (1) VERIZON WIRELESS E/911 GPS ANTENNA MOUNTED TO PROPOSED LIGHT STANDARD • INSTALLATION OF NEW 100 AMP ELECTRICAL SERVICE FROM EXISTING ELECTRICAL SWITCHGEAR • INSTALLATION OF A NEW TELCO SERVICE CONNECTION FROM AN EXISTING TELCO VAULT • MINOR LANDSCAPE AND IRRIGATION IS PLANNED FOR THIS PROJECT (REMOVE 2 EXISTING TREES, REMOVE 10 EXISTING SHRUBS, RELOCATE 6 EXISTING IRRIGATION CONTROL VALVES & ASSOCIATED IRRIGATION LINES, AND PLANT 6 NEW CLIMBING VINES) PROJECT ADDRESS: 2600 CARLSBAD BOULEVARD CARLSBAD, CA 92008 ASSESSORS PARCEL NUMBER: 203-054-33-00 EXISTING ZONING: GENERAL PLAN LAND USE: EXISTING LAND USE: PROPOSED LAND USE: TOTAL SITE AREA: PROPOSED PROJECT AREA: EQUIPMENT ENCLOSURE: V-R, VILLAGE REVIEW V, VILLAGE EDUCATIONAL FACILITY NO CHANGE 220,641 S.F. = 5.07 ACRES 225 S.F. NOTE: THERE ARE NO EXISTING TELECOMMUNICATION FACILITIES ON THIS PROPERTY RP 16-01 / CDP 16-03 T-1 A-0 A-1 A-2 A-3 A-4 A-5 A-6 LS1 LS2 LS3 SHEET SCHEDULE TITLE SHEET AND PROJECT DATA SITE PLAN ENLARGED SITE PLAN ENLARGED UTILITY PLAN EQUIPMENT PLAN LIGHT STANDARD PLAN EXTERIOR ELEVATIONS LIGHT STANDARD ELEVATION & DETAILS TOPOGRAPHIC SURVEY TOPOGRAPHIC SURVEY TOPOG"<APHIC SURVEY LEGAL DESCRIPTION THAT CERTAIN UNNAMED PARCEL ON PARCEL MAP NO. 21046, IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, RECORDED IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY ON MAY 7, 2013. ACCESSIBILITY DISCLAIMER THIS PROJECT IS AN UNOCCUPIED WIRELESS PCS TELECOMMUNICATIONS FACILITY AND, ACCORDING TO WRITTEN INTERPRETATION FROM THE CALIFORNIA DEPARTMENT OF THE STATE ARCHITECT, IS EXEMPT FROM DISABLED ACCESS REQUIREMENTS. APPLICABLE CODES ALL WORK SHALL COMPLY WITH THE FOLLOWING APPLICABLE CODES: CALIFORNIA STATE BUILDING CODE, TITLE 24, 2013 EDITION CALIFORNIA PLUMBING CODE, 2013 EDITION CALIFORNIA MECHANICAL CODE, 2013 EDITION CALIFORNIA ELECTRICAL CODE, 2013 EDITION CALIFORNIA FIRE CODE, 2013 EDITION CALIFORNIA ENERGY CODE, 2013 EDITION IN THE EVENT OF CONFLICT, THE MOST RESTRICTIVE CODE SHALL PREVAIL CITY OF CARLSBAD PLANNINGCOMMliSlOJI Case Nam Exhibit No~ • A,. -•. K-. llate! '1 " I ARCHITECTURE .. .. INCORPORATED 325 CAMSllAD VILLAGE DRIVE, SUITE D2 CARLSBAD. CA 92008 (760) 434-8474 ======== :: ======== PREPARED FOR ■ ver1zon P.O. BOX 19707 IRVINE, CA 92623-9707 (949) 286-7000 ======== :: ======== APPROVALS A&C DATE RE DATE RF DATE INT DATE EE/IN DATE OPS DATE EE/OUT DATE ======== :: ======== PROJECT NAME CARLSBAD STATE STREET 2600 CARLSBAD BOULEVARD CARLSBAD, CA 92008 SAN DIEGO COUNTY ======== :: ======== DRAWING DATES 12/05/14 12/12/14 01/12/15 03/10/16 90% ZD (se) 100% ZD (se) 100% ZD REVISION 100% ZD REVISION 1 (ic) 2 (se) ======== :: ======== SHEET TITLE TITLE SHEET & PROJECT DATA ======== :: ======== PROJECTS\ VERIZON\ 14186 ======== :: ======== T-1 ARMY AND NAV'f ACADEMY I I \ I I I \ \ l l \ \ BETA SECTOR AZIMUTH 230" l I \ \ \ \ \ \ N 82"43'47" E 10.00' ,/ GAMMA SECTOR AZIMUTH 350" + / ,,,.,,.( , . -/,L,,_,_," I ,,,. I ,,,---I ,,,. I _ _,.,,,. \ ,,,.,,,. \ \ \ \ \ MAGEE PARK \ \ \ \ \ N 34'02'59" W 4.03' SEE SHEET A-2 FOR ENLARGED UllLTTY PLAN \ \ \ \ \ \ \ SITE PLAN SCALE: 1"•50'-0- \ .,..... ,,......_ ..... , , . \ ___ ,,. .,,.,,, \ v.,,, .,.,,,.,.. \ ,,...,. \ , . , . , . , . ,, \ ,,,,,, \ \ \ \ ) \ \ \ \, \ l I \ \ \ SEE SHEET A-1 FOR ~--i ENLARGED SITE PLAN \ \ \ \ \ \ \ PROPOSED VERIZON WIRELESS -----1 TELECOMMUNICATIONS EQUIPMENT INSIDE A NEW CHAIN LINK FENCE ENCLOSURE ON A CONCRETE PAD ,---EXISTING 81'-1" HIGH STADIUM LIGHT STANDARD TO BE REMOVED, RELOCATE LIGHT FIXTURES AND BALLAST BOXES TO NEW STADIUM LIGHT STANDARD PROPOSED VERIZON WIRELESS ANTENNAS ~----1 MOUNTED ON A NEW 81'-1" HIGH STADIUM LIGHT STANDARD INSIDE A PERFORATED RF TRANSPARENT CONCEALMENT RADOME ~ EXISTING~ ASPHALT PAVED PARKING AREA FOR TRANSIT + "" RESIDENTIAL CENTER + 7 "" ALPHA SECTOR AZIMUTH 110" + RP 16-01 / CDP 16-03 SITE PLAN NOTES: 0 ~ ~ 0 ~ 1> <i> 1> 0 ~ EXISTING EASEMENT FOR LINE OF PIPE EXISTING EASEMENT FOR CONSTRUCTION AND MAINTENANCE OF POLES AND CROSS-ARMS FOR THE TRANSMISSION OF ELECTRIC CURRENT EXISTING EASEMENT FOR PUBLIC ROAD (ABANDONED) EXISTING EASEMENT FOR ROAD (ABANDONED) EXISTING EASEMENT FOR PUBLIC UTILITIES EXISTING EASEMENT FOR PUBLIC STREET AND PUBLIC UTILITY EXISTING EASEMENT FOR ACCESS AND PUBLIC UTILITY EXISTING DRIVEWAY FOR INGRESS/EGRESS EXISTING ASPHALT PAVED PARKING AREA PROPOSED VERIZON WIRELESS 12' -o" WIDE NON-EXCLUSIVE TECHNICIAN PARKING AND ACCESS PATH OF TRAVEL (SHOWN HATCHED) EXISTING STAIRCASE TOWER PROPOSED VERIZON WIRELESS JOINT UTILITY TRENCH TO LEASE AREA, PRELIMINARY UTILITY ROUTE TO BE FIELD VERIFIED AND ADJUSTED ACCORDINGLY DURING CONSTRUCTION PROPOSED 2' -o· x 3' -o· TELCO PULL BOX @ 250' -o· o.c. OR AFTER (2) SWEEPS MAX. (TYPICAL) PROPOSED 17" x 30" ELECTRICAL PULL BOX @ 250' -0" O.C. OR AFTER (2) SWEEPS MAX. (TYPICAL) EXISTING DRIVEWAY EXISTING WROUGHT IRON GATE EXISTING CONTOUR LINES AT 1 '-0" INTERVALS (TYP.) EXISTING CRIB WALL EXISTING DIRT SERVICE ROAD EXISTING CHAIN LINK FENCE EXISTING RAILROAD EXISTING STADIUM LIGHT STANDARD EXISTING SCOREBOARD EXISTING ELECTRICAL PULL BOX EXISTING STORM DRAIN INLET EXISTING STORM DRAIN MANHOLE EXISTING IRRIGATION BOX EXISTING ±20' -0" HIGH CHAIN LINK FENCE EXISTING STADIUM BLEACHERS EXISTING TREE (TYP.) EXISTING SEWER MANHOLE FIELD VERIFY AND LOCATE EXISTING UNDERGROUND STORM DRAIN LINES. DEEPEN UTILITIES TRENCH AS REQUIRED IN FIELD WHERE CONDUITS NEED TO CROSS BELOW EXISTING STORM DRAIN LINES (TYPICAL) EXISTING FIRE HYDRANT PROPOSED 17x30 TELCO PULL BOX WITH T"'~FFIC RATED COVER AT PROPERTY LINE (PROPOSED TELCO MMP OPTION 2) TELCO ROUTE DIST: ±245'-o" PROPOSED UNDERGROUND TELCO CONDUIT ROUTE IN TRENCH FROM TELCO MMP TO EQUIPMENT LEASE AREA (TELCO OPTION 2), PRELIMINARY UTILITY ROUTE TO BE FIELD VERIFIED AND ADJUSTED ACCORDINGLY DURING CONSTRUCTION \ \ \ \ \ EASEMENlS: \ \ \ \ \ \ ' EASEMENTS SHOWN REFLECT PRELIMINARY RECORDS RESEARCH OF RECORDED PARCEL MAPS & PRELIMINARY TITLE REPORT. EASEMENTS ARE SUBJECT TO REVIEW OF FINAL TITLE REPORT. SEE SHEET LS1 FOR ADDITIONAL INFORMATION ON NON PLOTTABLE EASEMENTS BOUNDARY NOTE: THE PROPERTY BOUNDARY LINES SHOWN ON THIS DRAWING ARE FOR REFERENCE ONLY. A BOUNDARY SURVEY WAS NOT PERFORMED ARCHITECTURE •• •• INCORPORATED 325 CARLSBAD VILLAGE DRIVE. SUITE D2 CAIUSOIID. Ci'! 9'2008 (760) 434-8.<!174 .. ======== .. PREPARED FOR ■ ver1zo P.O. BOX 19707 IRVINE, CA 92623-9707 (949) 286-7000 .. ========= .. APPROVALS A&C DATE RE DATE RF DATE INT DATE EE/IN DATE OPS DATE EE/OUT DATE ======== == ======== PROJECT NAME CARLSBAD STATE STREET 2600 CARLSBAD BOULEVARD CARLSBAD, CA 92008 SAN DIEGO COUNTY ======== :: ======== 12/05/14 12/12/14 01/12/15 03/10/16 DRAWING DATES 90% ZD (se) 100% ZD (se) 1 00% ZD REVISION 1 00% ZD REVISION ======== :: ======== SHEET TITLE SITE PLAN ======== :: ======== PROJECTS\ VERIZON\ 14186 ======== :: ======== A-0 I I I I I I I I I I I I I I I I I I I I I I I I I I "-~ EXISTING EASEMENT FOR PUBLIC UTILITIES I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I EXISTl~G EASEMENT FOR PUBLIC ROAD (ABANDONED) :,,.,,-EXISTING EASEMENT FOR CONSTRUCTION ,.,-, AND MAINTENANCE OF POLES AND : CROSS-ARMS FOR THE TRANSMISSION : OF ELECTRIC CURRENT 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 I I I I I I I \ I \ -----.,,,.,.- / " -------- EXISTING BUILDING ENLARGED SITE PLAN SCAI E· P • 10'--0" \ \ \ \ \ \ \ \ \ \ \ SEE SHEET A-4 FOR LIGHT STANDARD PLAN SEE SHEET A-3 FOR ~--1 EQUIPMENT PLAN PROPOSED VERIZON WIRELESS ~-TELECOMMUNICATIONS EQUIPMENT INSIDE A NEW CHAIN LINK FENCE ENCLOSURE ON A CONCRETE PAD l \ GAMMA SECTOR AZIMUTH 350" -........ 0 N " ---- ~EXISTING~ ATHLETIC FIELD ".._ RP 16-01 / CDP 16-03 ENLARGED SITE PLAN NOTES: <1> PROPOSED VERIZON WIRELESS NON-EXCLUSIVE ACCESS PATH OF TRAVEL (SHOWN HATCHED) PROPOSED VERIZON WIRELESS JOINT UTILITY TRENCH TO LEASE AREA, PRELIMINARY UTILITY ROUTE TO BE FIELD VERIFIED AND ADJUSTED ACCORDINGLY DURING CONSTRUCTION PROPOSED VERIZON WIRELESS COAX CABLE TRENCH FROM EQUIPMENT LEASE AREA TO ANTENNA LEASE AREA (SHOWN DASHED), PRELIMINARY COAX CABLE ROUTE TO BE FIELD VERIFIED AND ADJUSTED ACCORDINGLY DURING CONSTRUCTION EXISTING CONTOUR LINES AT 1 '-0" INTERVALS (TYP.) EXISTING ROOF OVERHANG (SHOWN DASHED) EXISTING CONCRETE SIDEWALK EXISTING CONCRETE BLOCK RETAINING WALL EXISTING CRIB WALL EXISTING DIRT SERVICE ROAD EXISTING CHAIN LINK FENCE EXISTING RAILROAD EXISTING STORM DRAIN MANHOLE EXISTING IRRIGATION BOX EXISTING ±20'-0" HIGH CHAIN LINK FENCE EXISTING CONCRETE STRIP EXISTING TREE (TYP.) EXISTING SEWER MANHOLE FIELD VERIFY AND LOCATE EXISTING UNDERGROUND STORM DRAIN LINES. DEEPEN UTILITIES TRENCH AS REQUIRED IN FIELD WHERE CONDUITS NEED TO CROSS BELOW EXISTING STORM DRAIN LINES (TYPICAL) EXISTING CHAIN LINK GATE PROPOSED UNDERGROUND TELCO CONDUIT ROUTE IN TRENCH FROM TELCO MMP TO EQUIPMENT LEASE AREA (TELCO OPTION 2) EXISTING 81'-1" HIGH STADIUM LIGHT STANDARD TO BE REMOVED, RELOCATE LIGHT FIXTURES AND BALLAST BOXES TO NEW STADIUM LIGHT STANDARD ·\;/ .• .. "">\. ' .•\'./>~:?>~,. PROPOSED VERIZON WIRELESS ANTENNAS MOUNTED ON A NEW 81 '-1" HIGH STADIUM LIGHT STANDARD INSIDE A PERFORATED + "" RF TRANSPARENT CONCEALMENT RADOME + "" ALPHA SECTOR AZIMUTH 11 O" 8 ARCHITECTURE .. .. I NCO RPO RATED 325 CARLSBAD VILLAGE DRIVE. SUITE D2 C~RLSBAD. CA 92008 (760) 434-8474 ======== :: ======== PREPARED FOR ■ ver1zon P .0. BOX 19707 IRVINE, CA 92623-9707 (949) 286-7000 ======== :: ======== APPROVALS A&C DATE RE DATE RF DATE INT DATE EE/IN DATE OPS DATE EE/OUT DATE ======== :: ======== PROJECT NAME CARLSBAD STATE STREET 2600 CARLSBAD BOULEVARD CARLSBAD, CA 92008 SAN DIEGO COUNTY ======== :: ======== DRAWING DATES 12/05/14 12/12/14 01/12/15 03/10/16 90% ZD (se) 100% ZD (se) 100% ZD REVISION 1 (ic) 100% ZD REVISION 2 (se) ======== :: ======== SHEET TITLE ENLARGED SITE PLAN ======== :: ======== PROJECTS\ VERIZON\ 14186 ======== :: ======== A-1 \ ' \ \ \ ' \ ' \ ' \ ' \ ' \ EXISTING DUGOUT \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ ' \ ' \ \ \ \ \ ' \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ EXISTING CALIFORNIA PARKS & REC BUILDING \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ ~------\ \ 0 \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ " --~ EXISTING~ ATHLETIC FIELD \,._ \ \ \ \ \ \ \ ENLARGED UTILITY PLAN SCALE: 1" • 10'-V CJ 0 D ( '-, CJ CJ r;;··-.. _____________________________ 0 -,_ 0 ', ~-------------------- ~ EXISTING~ ASPHALT PAVED PARKING AREA FOR CALIFORNIA PARKS & REC RP 16-01 / CDP 16-03 9 19 \ 4 ' ' ' -;. .,. --------------------,,, \ --------------------'\\ -;. \ \\ \ \, \ \\ ---------------------- ----------------------,_ \\-;. \ .. \\ \ \ ', \<\ \ -;. \\\ 0 ',\ \. ___ _ ••, ----\ So "-,, __ A \,\\ \:\ \~\ '*-.., .. \ <74:>--', .... ______ ...... _ ENLARGED UTILITY PLAN NOTES: 0 ~ ~ ~ <t} q} ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ EXISTNG TELCO VAULT IN PARKWAY PLANTER (PROPOSED TELCO P.O,C.) TELCO ROUTE DIST: ±965' -0" PROPOSED 4"¢ TELCO CONDUIT IN AN UNDERGROUND TRENCH, PRELIMINARY UTILITY ROUTE TO BE FIELD VERIFIED AND ADJUSTED ACCORDINGLY DURING CONSTRUCTION PROPOSED 2' -0" x 3' -0" TELCO PULL BOX WITH TRAFFIC RATED COVER (AT PROPERTY LINE PROPOSED TELCO MMP) EXISTING CONCRETE BLOCK ELECTRICAL ENCLOSURE WITH CHAIN LINK GATES EXISTING ELECTRICAL SWITCHGEAR INSIDE ELECTRICAL ENCLOSURE AT GRADE (PROPOSED ELECTRICAL P.O.C.) ELECTRICAL ROUTE DIST: ±735'-0" PROPOSED VERIZON WIRELESS ELECTRICAL METER MOUNTED TO WALL PROPOSED VERIZON WIRELESS STEP-UP ELECTRICAL TRANSFORMER ON A CONCRETE PAD PROPOSED ELECTRICAL CONDUIT IN AN UNDERGROUND TRENCH, PRELIMINARY UTILITY ROUTE TO BE FIELD VERIFIED AND ADJUSTED ACCORDINGLY DURING CONSTRUCTION PROPOSED VERIZON WIRELESS JOINT UTILITY TRENCH TO LEASE AREA, PRELIMINARY UTILITY ROUTE TO BE FIELD VERIFIED AND ADJUSTED ACCORDINGLY DURING CONSTRUCTION EXISTING FIRE HYDRANT EXISTING STREET LIGHT ~ EXISTING DRIVEWAY EXISTING STREET LIGHT BOX ~ EXISTING STUCCO COLUMN EXISTING WATER METER BOX ~ EXISTING WROUGHT IRON GATE EXISTING UTILITY POLE #P28708J ff EXISTING WROUGHT IRON FENCE EXISTING MAILBOX ~ EXISTING CHAIN LINK FENCE EXISTNG LANDSCAPE PARKWAY ~ EXISTING STADIUM LIGHT EXISTING CONCRETE SIDEWALK ~ EXISTING PARKING LIGHT EXISTING CONCRETE CURB ~ EXISTING STORM DRAIN INLET EXISTING CONCRETE GUTTER ~ EXISTING IRRIGATION BOX (TYP.) EXISTNG SDG&E TRANSFORMER ~ EXISTING RETAINING WALL #D213281 CIR 781 ~ EXISTING TREE (TYP.) EXISTING BOLLARDS ~ EXISTING LANDSCAPE AREA EXISTING WALL ~ EXISTING CONTOUR LINES EXISTING ASPHALT PAVED AT 1 '-0" INTERVALS (TYP.) PARKING AREA ~RCHITECTURE ■■ ■■ INCORPORATED 325 CARLSBAD VILLAGE DRIVE. SUITE D2 CARLSBAD, CA 92008 (760) 434-8H4 ======== :: ======== PREPARED FOR verizon✓ P .0. BOX 19707 IRVINE, CA 92623-9707 (949) 286-7000 ======== :: ======== APPROVALS A&C DATE RE DATE RF DATE INT DATE EE/IN DATE OPS DATE EE/OUT DATE ======== :: ======== PROJECT NAME CARLSBAD STATE STREET 2600 CARLSBAD BOULEVARD CARLSBAD, CA 92008 SAN DIEGO COUNTY ======== :: ======== DRAWING DATES 12/05/14 12/12/14 01/12/15 03/10/16 90% ZD (se) 100% ZD (se) 100% ZD REVISION 100% ZD REVISION ======== :: ======== SHEET TITLE ENLARGED UTILITY PLAN ======== :: ======== PROJECTS\ VERIZON\ 14186 ======== :: ======== A-2 • 1 .,,. o. \ .,,. o, • EXISTING BUILDING 19 • 1· ,.....() EQUIPMENT PLAN SCALE: SIB" .1•.qo \ ' 5 \ . "\ . ' \\'-. " \" . \. ,,,,,o 1" . ' \ ' \.. 1" -, ~/ . \ \ \ \ ' ' ' ' ' ' ' ' ' ' , \/ + • RP 16-01 / CDP 16-03 EQUIPMENT PLAN NOTES: 0 ~ PROPOSED VERIZON WIRELESS EQUIPMENT INSIDE A NEW CHAIN LINK FENCE EQUIPMENT ENCLOSURE ON A CONCRETE PAD. PROPOSED VERIZON WIRELESS 15kW DC ENCLOSED STANDBY GENERATOR WITH A 54 GALLON DOUBLE WALL SUBBASE FUEL TANK ON A POURED-IN-PLACE CONCRETE PAD PROPOSED VERIZON WIRELIESS 'MACRO CELL EVOLUTION' OUTDOOR EQUIPMENT CABINET (TYPICAL OF 2). CABINET COMPONENTS: POWER PLANT, CWDM, FIBER DISTRIBUTION, RAYCAPS, BATTERIES-3 STRINGS, & AC-PANEL (EQUIP WITH A REVERSE SERVICE GENERATOR RECEPTACLE FOR STANDBY GENERATOR CONNECTION) <'.9 PROPOSED UNDERGROUND 4"0 ANTENNA CABLE CONDUIT ROUTING TO STUB UP BENEATH CABINETS (TYPICAL) 0 ~ <i> ~ ~ ~ <& ~ ~ ~ ~ ~ ~ ~ ~ ~ {} ~ ~ <& ~ ~ ~ ~ ~ ~ ~ <{) PROPOSED POURED-IN-PLACE CONCRETE PAD FOR VERIZON WIRELIESS EQUIPMENT PROPOSED RAISED CONCRETE PAD FOR VERIZON WIRELIESS CABINETS PROPOSED UNISTRUT H-FRAME PROPOSED FUSED DISCONNECT SWITCH UNISTRUT MOUNTED TO H-FRAME PROPOSED "SUN WEST" TELCO CABINET UNISTRUT MOUNTED TO H-FRAME PROPOSED "CIENA" TELCO EQUIPMENT UNISTRUT MOUNTED TO H-FRAME PROVIDE AND INSTALL (1) CLASS "ABC" FIRE EXTINGUISHER IN A WEATHERPROOF CABINET MOUNTED TO UNISTRUT PROVIDE AND INSTALL BATTERY ACID SPILL KIT(S) CAPABLE OF NEUTRALIZING A SPILL FROM THE LARGEST BATTERY PROPOSED OPENING FOR CONDUIT PENETRATION BELOW (SHOWN DASHED) CONCRETE SLOPED TO DRAIN. 1 % MIN. PROPOSED UNDERGROUND C0"1<. CABLE TRENCH (SHOWN DASHED) EXISTING LANDSCAPE AREA EXISTING TREE TO REMAIN EXISTING TREE TO BE REMOVED (SHOWN DASHED) (TYPICAL OF 2 TOTAL) EXISTING SHRUBS TO REMAIN (TYPICAL) EXISTING SHRUBS TO BE REMOVED (SHOWN DASHED) (TYPICAL OF 10 TOTAL) PROPOSED CLIMBING VINES -5 GAL. (TYPICAL OF 6) CREEPING FIG -FICUS PUMILA MATURE HEIGHT 15' x 1 O' SPREAD (SHOWN SHADED) EXISTING IRRIGATION CONTROL VALVE PROPOSED 6' -0" HIGH CHAIN LINK FENCE (FIELD VERIFY TO MATCH EXISTING CHAIN LINK FENCE HEIGHT PROPOSED 3' -o• WIDE CHAIN LINK GATE AND FRAME WITH LOCKABLE ACCESS AND VERIZON WIRELIESS SIGNAGE PROPOSED UNDERGROUND TELCO CONDUIT ROUTING IN TRENCH FROM TELCO P.O.C. TO EQUIPMENT ENCLOSURE PROPOSED UNDERGROUND ELECTRICAL CONDUIT ROUTING IN TRENCH FROM ELECTRICAL P.O.C. TO EQUIPMENT ENCLOSURE PROPOSED JOINT UTILITY TRENCH (ELECTRICAL AND TELCO) PROPOSED 2' -o· x 3' -o· TELCO PULL BOX WITH TRAFFIC RATED COVER PROPOSED 17" x 30" ELECTRICAL PULL BOX WITH TRAFFIC RATED COVER PROPOSED VERIZON WIRELIESS STEP-DOWN ELECTRICAL TRANSFORMER ON A CONCRETE PAD EXISTING IRRIGATION CONTROL VALVE TO BE RELOCATED (SHOWN DASHED) (TYPICAL OF 6) PROPOSED RELOCATION OF IRRIGATION CONTROL VALVE. PRELIMINARY LOCATION, TO BE FIELD VERIFIED AND ADJUSTED ACCORDINGLY DURING CONSTRUCTION (TYPICAL) EXISTING STORM DRAIN INLET EXISTING CONCRETE WALKWAY EXISTING BUILDING EXTERIOR WALL (TYPICAL) EXISTING WINDOW (TYPICAL) EXISTING ROOF OVERHANG ABOVE (SHOWN DASHED) EXISTING DOWNSPOUT EXISTING 6' -0" HIGH CHAIN LINK FENCE ON WALL (FIELD VERIFY) EXISTING RETAINING WALL EXISTING DIRT SERVICE ROAID DAYLIGHT END OF EXISTING UNDERGROUND DRAIN EXISTING SPLASH BLOCK GENERAL NOTE: ALL PROPOSED CABINETS, UTILITY EQUIPMENT AND H-FRAME EXPOSED SURFACES SHALL BE PAINTED WHITE TO MATCH EXISTING BUILDING ARCHITECTURE ■■ ■■ INCORPORATED 325 CARLSDAD ~IUAGE DRIVE. SUITE D2 CSRLSDAD. CS 92008 (760) 434-8474 ======== == ======== PREPARED FOR ■ ver1zon P.O. BOX 19707 IRVINE, CA 92623-9707 (949) 286-7000 ======== == ======== APPROVALS A&C DATE RE DATE RF DATE INT DATE EE/IN DATE OPS DATE EE/OUT DATE ========= -· ■■ PROJECT NAME CARLSBAD STATE STREET 2600 CARLSBAD BOULEVARD CARLSBAD, CA 92008 SAN DIEGO COUNTY ========= .. ■■ 12/05/14 12/12/14 01/12/15 03/10/16 DRAWING DATES 90% ZD (se) 100% ZD (se) 100% ZD REVISION 1 (ic) 100% ZD REVISION 2 {se) ========= .. ■■ SHEET TITLE EQUIPMENT PLAN ======== == ======== PROJECTS\ VERIZON\ 14186 ======== :: ======== A-3 ' \ \ \ \ \ \ \ . EXISTING BUILDING \ \ \ \ \ \ \ \ \ \ .\ \ . \ \ \ \ . \ \ \ . \ \ ' \ \ \ \ ' ' .\ \ \ . ' \ \ \ \ \ ' \ ' \ \ \ ' .\ \ \ \ \ ·-·-·~· .. \~·_J . . \ \ . \ . . . \ \ \ . \ \ \ \ \ \ \ \ \ \ \ \ --·\ --.... _ \ ---. \ . ---\ --\ --, ,,..,.,.,.,.,,.,,,..,.,.✓ / \ • ' 14 + • • + + /i 8 6 4 42.2' F.S. + + LIGHT STANDARD PLAN SCALE: Wlr' • 1'-0- RP 16-01 / CDP 16-03 LIGHT STANDARD PLAN NOTES: 0 %> 0 0 ~ ~ PROPOSED VERIZON WIRELESS 81'-1" HIGH x 24"¢ LIGHT STANDARD PROPOSED 36"¢ LIGHT STANDARD CONCRETE CAISSON FOOTING PROPOSED ( 4) 4"¢ CDAX CABLE CONDUITS PROPOSED CONCRETE PULL BOX WITH TRAFFIC LID PROPOSED UNDERGROUND COAX CABLE TRENCH (SHOWN DASHED) EXISTING 81'-1" HIGH x 16"¢ STADIUM LIGHT STANDARD TO BE REMOVED (SHOWN DASHED) 0 EXISTING BALLAST BOXES TO BE RELOCATED TO NEW STADIUM LJGHT STANDARD (SHOWN DASHED) ~ EXISTING LIGHT FIXTURES TO BE RELOCATED TO NEW STADIUM LJGHT STANDARD (SHOWN DASHED) EXISTING STORM DRAIN INLET PROPOSED TELCO CONDUIT ROUTING FROM TELCO P.0.C. TO EQUIPMENT ENCLOSURE PROPOSED ELECTRICAL CONDUIT ROUTING FROM ELECTRICAL P.O.C. TO EQUIPMENT ENCLOSURE PROPOSED JOINT UTILITY TRENCH (ELECTRICAL AND TELCO) EXISTING LANDSCAPE AREA EXISTING TREE TO REMAIN (TYPICAL) EXISTING CONCRETE WALKWAY EXISTING BUILDING EXTERIOR WALL (TYPICAL) EXISTING ROOF OVERHANG ABOVE (SHOWN DASHED) EXISTING DOWNSPOUT EXISTING CHAIN LINK FENCE EXISTING RETAINING WALL EXISTING DIRT SERVICE ROAD EXISTING CONTOUR LINES AT 1 '-0" INTERVALS EXISTING CRIB WALL EXISTING ±20'-0" HIGH CHAIN LINK FENCE EXISTING CONCRETE STRIP OUTLINE OF PROPOSED 4' -0"¢ RADOME ABOVE (SHOWN DASHED) FIELD VERIFY AND LOCATE EXISTING UNDERGROUND STORM DRAIN LINES. DEEPEN UTILITIES TRENCH AS REQUIRED IN FIELD WHERE CONDUITS NEED TO CROSS BELOW EXISTING STORM DRAIN LINES (TYPICAL) EXISTING CHAIN LINK GATE EXISTING IRRIGATION CONTROL VALVE ARCHITECTURE .. .. INCORPORATED 325 CARLSBAD VILLAGf DRIVf. SUITf DQ CARLSBAD. CA 9QOOB (760) 434-8474 ======== :: ======== PREPARED FOR ■ ver1zon P.O. BOX 19707 IRVINE, CA 92623-9707 (949) 286-7000 ======== :: ======== APPROVALS A&C DATE RE DATE RF DATE INT DATE EE/IN DATE OPS DATE EE/OUT DATE ======== :: ======== PROJECT NAME CARLSBAD STATE STREET 2600 CARLSBAD BOULEVARD CARLSBAD, CA 92008 SAN DIEGO COUNTY ======== :: ======== 12/05/14 12/12/14 01/12/15 03/10/16 DRAWING DATES 90% ZD (se) 100% ZD (se) 1 00% ZD REVISION 1 00% ZD REVISION ======== :: ======== SHEET TITLE LIGHT STANDARD PLAN ======== :: ======== PROJECTS\ VERIZON\ 14186 ======== :: ======== A-4 5 122.8' TOP OF LIGHT STANDARD -~~,--~__:_.:c:__=----==-c-'-'------'-~----~-------::~~=-n PROPOSED VERIZON WIRELESS ANTENNAS MOUNTED ON A ~--. NEW 81'-1" HIGH STADIUM LIGHT STANDARD o'-o" A.G.L. 1 41.7' F.G. 19 1 4 .J 0 ... ~ --OJ ~ ' -I . -OJ ~ .... I "' w I _J _J <( I>: w > ~ ' I>: O> :::, I .... u O> :::, co I>: .... rn ~ 11 •:1, ;:? ----CENTERLINE OF VERIZON -----iffil l~l WIRELESS ANTENNAS rill isl L!.i ltru r,~I ITT I 11 11 ' O> I . -co ,;,. i' ___ CENTEfLINE QF VER!ZON ____ t[) 1:f.': WIRELESS ANTENNAS (iii /ti Lill lii.J ~-PROPOSED VERIZON WIRELESS __...-:;;c~ RRU'S AND RAYCAPS MOUNTED 5 8 Ot· ON PROPOSED 81' -1 • HIGH STADIUM LIGHT STANDARD wi-i , 1 4 2 11 11 11 11 II~ IV - 11 11 EAST ELEVATION PROPOSED VERIZON WIRELESS ANTENNAS MOUNTED ON A .,,,,---a NEW 81'-1" HIGH STADIUM LIGHT STANDARD ...---PROPOSED VERIZON WIRELESS ---~ RRU'S AND RAYCAPS MOUNTED ON PROPOSED 81'-1" HIGH STADIUM LIGHT STANDARD PROPOSED VERIZON WIRELESS TELECOMMUNICATIONS EQUIPMENT INSIDE A NEW CHAIN LINK FENCE ENCLOSURE ON A CONCRETE PAD EXISTING BUILDING --~--,;----__ _J-----II----,----,;------ 11 II : II ll II II II 11 II II II --db.--~~-->---.d.l' II II :: II I ii Ii 11..---' __ ...... __ ....._ ____ _ ....iir--------· - EXISTING BUILDING r----~----~---J881 -~-08 ~----IBRI --~ 1881 ~-II II Ii II II II II II II 11 11 11 II II II II 11 ' ' 11 11 II II II U II i 11 11 II II II I II ! '--....11..--....:..-~....i..--....11. ____ ...... _____ ...... 10 EXISTING BUILDING --- 8 II II -~- NORTH ELEVATION SOUTH ELEVATION SCALE: 3132" • 1'-<I" PROPOSED VERIZON WIRELESS TELECOMMUNICATIONS EQUIPMENT INSIDE A NEW CHAIN LINK FENCE ENCLOSURE ON A CONCRETE PAD 6 5 19 4 2 RP 16-01 / CDP 16-03 ELEVATION NOTES: «> 0 ~ 0 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ==t=-= I I I I I I I I I I I I I I I I I I PROPOSED VERIZON WIRELESS 81 '-1" HIGH x 24"¢ LIGHT STANDARD PROPOSED 36"¢ LIGHT STANDARD CONCRETE CAISSON FOOTING EXISTING 81 '-1 • HIGH x 16"¢ STADIUM LIGHT STANDARD TO BE REMOVED (SHOWN DASHED) EXISTING BALLAST BOXES FROM REMOVED 81 '-1" HIGH STADIUM LIGHT STANDARD TO BE RELOCATED TO NEW STADIUM LIGHT STANDARD EXISTING LIGHT FIXTURES FROM REMOVED 81 '-1" HIGH STADIUM LIGHT STANDARD TO BE RELOCATED TO NEW STADIUM LIGHT stANDARD PROPOSED 6' -0" HIGH CHAIN LINK Fil:NCE (FIELD VERIFY TO MATCH EXISTING CHAIN LINK FENC~ HEIGHT PROPOSED VERIZON WIRELESS UTILl1Y CABINETS UNISTRUT MOUNTED TO H-FRAME PROPOSED VERIZON WIRELESS STEP-DOWN ELECTRICAL TRANSFORMER ON A CONCRETE PAD EXISTING BUILDING EXTERIOR WALL EXISTING WINDOW (1YPICAL) EXISTING ROOF OVERHANG EXISTING DOWNSPOUT EXISTING 6' -0" HIGH CHAIN LINK FENCE IN FOREGROUND (FIELD VERIFY)(SH0WN DASHED FOR CLARI1Y) EXISTING RETAINING WALL IN FOREGROUND (SHOWN DASHED FOR CLARl1Y) EXISTING CRIB WALL (IN FOREGROUND SHOWN DASHED FOR CLARl1Y) EXISTING ±20' -0" HIGH CHAIN LINK FENCE EXISTING CONCRETE STRIP EXISTING GRADE PROPOSED 4' -0"¢ RADOME PROPOSED 3' -0" WIDE CHAIN LINK GATE AND FRAME WITH LOCKABLE ACCESS AND VERIZON WIRELESS SIGNAGE GENERAL NOTE: ALL PROPOSED CABINETS, UTILl1Y EQUIPMENT AND H-FRAME EXPOSED SURFACES SHALL BE PAINTED WHITE TO MATCH EXISTING BUILDING PROPOSED VERIZON WIRELESS ANTENNAS MOUNTED ON A .-r-----1 NEW 81 '-1" HIGH STADIUM LIGHT STANDARD ~-PROPOSED VERIZON WIRELESS ---~ RRU'S AND RAYCAPS MOUNTED 1 ON PROPOSED 81 '-1" HIGH STADIUM LIGHT STANDARD ARCHITECTURE .. .. INCORPORATED 325 CARLSDAD VILLAGE DRIVE. SUITE D2 CARLSOAD. CA 92008 (760) 434-8n4 ======== :: ======== PREPARED FOR ■ ver1zon P .0. BOX 19707 IRVINE, CA 92623-9707 (949) 286-7000 ======== :: ======== APPROVALS A&C DATE RE DATE RF DATE INT DATE EE/IN DATE OPS DATE EE/OUT DATE ======== :: ======== PROJECT NAME CARLSBAD STATE STREET 2600 CARLSBAD BOULEVARD CARLSBAD, CA 92008 SAN DIEGO COUNTY ======== :: ======== DRAWING DATES 12/05/14 12/12/14 01/12/15 03/10/16 90% ZD (se) 100% ZD (se) 100% ZD REVISION 1 (ic) 100% ZD REVISION 2 (se) ======== :: ======== SHEET TITLE EXTERIOR ELEVATIONS ======== :: ======== PROJECTS\ VERIZON\ 14186 ======== :: ======== A-5 OUTLINE OF 4'-0" DIA. CONCEALMENT RADOME BELOW PROPOSED 1 0"¢ STEEL PIPE MAST LIGHT FIXTURE ___/····- ORIENTATION ABOVE (SHOWN DASHED) PROPOSED VERIZON WIRELESS GPS ANTENNA GPS ANTENNA MOUNT PLAN AT GPS ANTENNA PROPOSED 10"¢ -~ STEEL Pl PE MAST 3/8"¢ STAINLESS STEEL U-BOLT PROPOSED GPS COAX CABLE GPS ANTENNA MOUNT OUTLINE OF 4'-0" DIA. CONCEALMENT RADOME ANTENNAS G1 -G2 AZIMUTH 350" ANTENNAS 81-82 AZIMUTH 230" .. PROPOSED 10"¢ -----~ STEEL PIPE MAST PLAN AT ANTENNAS OUTLJNE OF 4'-0" DIA. CONCEALMENT RADOME PROPOSED 10"¢ STEEL PIPE MAST 260" ♦ 350" 170" PLAN AT RRU'S & RAYCAPS STAINLESS STEEL BANDING SCALE 1/2"=1 '-o" PROPOSED VERIZON WIRELESS GPS ANTENNA STAINLESS STEEL MOUNTING BRACKET STAINLESS STEEL BANDING 1 TOP OF PROPOSED CONCEALMENT RADOME SCALE 1"=1'-0" 2 PROPOSED VERIZON WIRELESS PANEL ANTENNA PROPOSED ANTENNA DOWNTILT BRACKET PROPOSED 2"¢ STD. STEEL PIPE ANTENNAS A1-A2 AZIMUTH 11 o· SCALE 1;2·=1 '-0" 3 PROPOSED VERIZON WIRELESS RRU UNIT GALV. STEEL MOUNTING PLATE ASSEMBLY (TYP.) • 80" SCALE 1 /2"=1 · -o" 4 ANTENNA AND COAXIAL CABLE SCHEDULE SECTOR ANTENNA ALPHA 1 ALPHA 2 BETA 1 BETA 2 GAMMA 1 GAMMA 2 DIRECTON AZIMUTH SOUTHEAST 11 er SOUTHWEST 230" NORTH 350" 1/8"¢ TYPICAL DOWNTILT SKEW SIZE ANGLE o· N/A 78" L X 18" W X 10" D o· N/A 78" L x 18" W x 10· D o· N/A 78" L x 18" W x 10" D o· N/A 78" L X 18" W X 10" D o· N/A 78" L x 18" w x 1 o" D o· N/A 78" L x 18" w x 1 o· D RADOME PERFORATED HOLE PATTERN SCALE 1 = 1 5 PROPOSED ANTENNA-+-- DOWNTILT BRACKET GALV. STEEL __ __...- MOUNTING PLATE ASSEMBLY (TYP.) PROPOSED ANTENNA DOWNTILT BRACKET PROPOSED 10"¢ __ _,,. STEEL Pl PE MAST \ TYPICAL ANTENNA MOUNT PROPOSED VERIZON WIREUESS RAYCAP DC SURGE PROTECTION UN IT PER PLAN GALV. STEEL -~~~---- MOUNTING PLATE ASSEMBLY (TYP.) PROPOSED--_...-- CONCEALMENT RADOME RRU & RAYCAP MOUNT / ! i ' • I ' PROPOSED VERIZON WIRELESS PANEL ANTENNA PER PLAN PROPOSED CONCEALMENT RADOME PROPOSED GALV. STEEL U-BOLTS PROPOSED RET '-----PROPOSED JUMPER CABLES SCALE 1 /2"=1 '-0" ~--PROPOSED 10"¢ STEEL PIPE MAST 6 PROPOSED RRU MOUNTING BRACKET PROPOSED VERIZON WIRELESS RRU ) UNIT PER PLAN '----le---PROPOSED JUMPER CABLES '-----PROPOSED HYBRID TRUNK CABLE SCALE 1 /2"=1 '-0" 7 RRU NUMBER REQUIREMENTS OF CABLES PER SECTOR PER SECTOR ( 4) 1 /2" COAX JUMPERS + (1) RRU (2) (1 x1) HYBRID JUMPERS + 1YPICAL PER (2) 8 MM RET CABLES ANTENNA PER (4) 1/2" COAX SECTOR, MODEL T.B.D. JUMPERS + (2) (1x1) HYBRID (Bl.ACK BOX SIZE: 32"H JUMPERS + X 22"W (2) 8 MM RET CABLES x 1 O"D, (4) 1/2" COAX 100 LBS.) JUMPERS + (2) (1x1) HYBRID JUMPERS + (2) 8 MM RET CABLES 8" X 16" X 3/8" THK. GALV. STEEL MOUNTING PLATE 3" X 10" X 1/2" -- THK. GALV. STEEL STANDOFF PLATE TYPICA~ 3/16• JUMPER LENGTl-l (+/-3') 20'-0" 15'-o" 20'-o" 15•-o· 20'-o" 15'-0" MOUNTING PLATE ASSEMBL PER PLAN PROPOSED LIGHT STANDARD ® POLE PLAN AT UPPER HANDH PER PLAN . " 1 1/2"¢ PVC --- CONDUIT FOR -i+-.J::~v GROUND PROPOSED LIGHT STANDARD CABLE CABLE SIZE LENGTl-l & QTY (+/-5') (2) (6x12) 21 o· -o· HYBRID TRUNK CABLES ..----PROPOSED 10"¢ STEEL Pl PE MAST • t') 0 • t') SCALE 1"=1'-0" 8 PROVIDE (2) 6" x 12" HAN DH OLES (4) 4"¢ SCHEDULE 40 PVC COAXIAL CABLE CONDUITS (BELOW) (2) 1 "¢ POWER CONDUIT TO LIGHT FIXTURES PROVIDE (2) 9" x 24" HANDHOLES T.B.D. 0 POLE PLAN AT LOWER HANDHOI..ES @ 3'-6" SECTION AT HANDHa.ES SCALE 1/2"=1 ·-o· 1 " THICK A36 STEEL SPLICE PLATE (GALV.) PROPOSED 10"¢ -~ STANDARD GALV. STEEL PIPE MAST PROPOSED LIGHT STANDARD I I I I I 1 1/2"¢ PVC CONDUIT FOR GROUND ~--(2) 1 "¢ POWER CONDUIT TO LIGHT FIXTURES (2) (6x12) HYBRID TRUNK CABLES 1 /2"¢ COAX CABLE FOR GPS 9 LIGHT STANDARD UPPPER PORTS SCALE 1"=1'-0" 10 " -I " -<Xl • 0) I 0) <D 10.75" POLE DIAMETER AT TOP--~ OF PROPOSED NEW 81 '-1" HIGH LIGHT STANDARD TOP OF VERIZON WIRELESS LIGHT STANDARD BOTTOM OF LIGHT FIXTURES (VERIFY HEIGHT P[R MANUFACTURER) ';,_ ~ • ,,, I " -<D • <Xl I "' "' TOP OF VERIZON WIRELESS RADOME CENTER OF VERIZON WIRELESS ANTENNAS I -' "' u PROPOSED 4'-0"¢ PERFORATED---"- RF TRANSPARENT CONCEALMENT !j;frljlll RADOME (SHOWN SHADED) SEE DETAIL~ -'k---lc ~ CENTER OF VERIZON WIRELESS ANTENNAS CENTER OF VERIZON WIRELESS RRU'S • <D .· T _ CENTER OF VERIZON ____ _::___:=Efc:, ~~F1fjF--' 1 WIRELESS RRU'S 'c, ' <Xl I " -"' CENTERLJNE OF HANDHOLES .. 1 :: --'l<---+,c,,,,.,,,.·,,,' .,,. •.•,,•,•, ...-V .,. _ _,.,_ ... -- PROVIDE (2) 6" x 12" --✓ HANDHOLES (TYPICAL) 24" POUE DIAMETER -----__.J_ BALLAST BOXES -----.._ PROVIDE (1) 5" x 8" -~ HANDHOLE (2) 9" x 24" HANDHOLES WITH COVER 't CENTERLJNE OF HANDHOLES __ _ ~ I EXISTING FINISH GRADE RP 16-01 / CDP 16-03 RELOCATE EXISTING LIGHT FIXTURES TO PROPOSED LIGHT STANDARD (7 TOTAL) PROPOSED GPS ANTENNA (TYP. OF 1) IF SECOND CABINET IS INSTALLED THEN A SPUTTER WILL BE REQUIRED PROPOSED VERIZON WIREUESS >--¾ ANTENNAS MOUNTED INSIDE NEW 48"¢ R.~DOME ON A NEW 81 '-1' HIGH LIGHT STANDARD. PROPOSED VERIZON WIRELESS RRU'S (TYPICAL OF 6 TOTAL) PROPOSED VERIZON WIREUESS RAYCAP DC SURGE PROTECTION (TYPICAL OF 2 TOTAL) • <O I ,,, UNIT • <Xl I ~ • 0 I .... N • N I ~ "' /!'!.·~~~ ----....1..---1 , ' ... =-=-=-=-=-=-=-=-=-=-=-::.=-=-=-=-=-:.::.=-=-=--=====::~===~:::'.._ _ _,l_ ..,__~,.__,, _ _..,.__.,_____--'<-------: ·11 __ 11-.,l.:1._ CONCRETE CAISSON ---< FOOTING AND REINFORCING PER MANUFACTURER \" 11. \ -,, '~ . ir-~ . C \ \\ ·~ , .. -.:I,"' \\ ' . \ .\\. 21' .·, 'Z, ..... __ ..... .', ' .... ---------. -. ======] ~ . ",.:.__ ..... :·:.-:. __ ======== . -. ------] •. • •-•: .: ---~-------.__~_,---~(4) 4"¢ SCHEDULE 40 PVC CONDUITS FOR COAXIAL CABLE ~-24" x 36" x 48" DEEP COAX CABLE PULL BOX WITH TRAFFIC RATED COVER ~----PROPOSED (4) 4"¢ CONDUITS FOR COAX CABLE (1) 1-1/2"¢ CONDUIT FOR GROUND LIGHT STANDARD & (2) 1 "¢ CONDUITS FOR POWER 11 RCH ITECTURE .. .. I NCORPORl1TED 325 CAMSDAD VILLAGE DRIVE. SUITE D2 CARLSOAD. CA 92008 (760) 434-8474 ======== :: ======== PREPARED FOR ■ ver1zon P.O. BOX 19707 IRVINE, CA 92623-9707 (949) 286-7000 ==== :: ==== APPROVALS A&C DATE RE DATE RF DATE INT DATE EE/IN DATE OPS DATE EE/OUT DATE ======== == ======== PROJECT NAME CARLSBAD STATE STREET 2600 CARLSBAD BOULEVARD CARLSBAD, CA 92008 SAN DIEGO COUNTY ======== :: ======== 12/05/14 12/12/14 01/12/15 03/10/16 DRAWING DATES 90% ZD (se} 100% ZD (se) 100% ZD REVISION 1 (ic} 100% ZD REVISION 2 (se) ======== :: ======== SHEET TITLE LIGHT STANDARD ELEVATION & DETAILS ======== :: ======== PROJECTS\ VERIZON\ 14186 ========== ======== A-6 OWNER'S NAME: ARMY AND NAVY ACADEMY ASSESSOR'S PARCEL NUMBER(S) 203-054-33-00 BASIS OF BEARINGS: (NAD 83; Epoch 2002) THE BEARINGS SHOWN HEREON ARE BASED ON NAD 1983 CALIFORNIA STATE PLANE COORDINATE SYSTEM -ZONE 6. AS DETERMINED BY G.P.S. OBSERVATIONS, USING TRIMBLE 5700/5800 RECEIVERS ANO TRIMBLE GEODETIC OFFICE 1.60 SOFTWARE. BASIS OF ELEVATIONS: NAVO 1988 ELEVATIONS ARE BASED ON GPS OBSERVATIONS FROM TWO NATIONAL GEODETIC SURVEY C.O.R.S. REFERENCE STATIONS: 1) PL05, ELEVATION = 44.85' AND 2) SI03, ELEVATION = 237.75' WITH GEOID 2012 CORRECTIONS APPLIED. SITE DATA FEMA FLOOD ZONE DESIGNATION: County: Son Diego Map/Panel: 06073C0761 G The Flood Zone Designation National Flood Insurance Program: Effective Date: 5/16/2012 for this site is: ZONE: X FEMA FLOOD ZONE INFORMATION THAT CERTAIN UNNAMED PARCEL ON PARCEL MAP NO. 21046, IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, RECORDED IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY ON MAY 7, 2013. PROPERTY LEGAL DESCRIPTION TITLE REPORT NOTES: THE FOLLOWING EASEMENTS EFFECT SAID PARCEL AND ARE SHOWN HEREON. SEE PRELIMINARY TITLE REPORT NO. 08022936 PREPARED BY COMMONWEALTH LAND TITLE COMPANY AND DATED JUNE 20, 2014 FOR OTHER DOCUMENTS (NON-EASEMENTS) EFFECTING SAID PROPERTY. ITEM #2 -Easement(s) for the purpose(s) shown below and rights incidental thereto, as delineated on or as offered for dedication on Mop/Plat: Mop No. 2037 Purpose: poles or other similar structures (AS SHOWN HEREON -ROW) ITEM #4 -Easement(s) for the purpose(s) shown below and rights incidental thereto, as granted in a document: Granted ta: Oceanside Mutual Water Company, o corporation Purpose: line of pipe Recorded: in Book 1823 Page 17 of Deeds (AS SHOWN HEREON) ITEM #5 -Easement(s) for the purpose(s) shown below and rights incidental thereto, as granted in a document: Granted to: San Diego Consolidated Gas & Electric Company Purpose: construction and maintenance of poles and cross-arms for the transmission of electric current Recorded: in Book 268 Page 231 of Official Records (AS SHOWN HEREON) ITEM #6 -Easement(s) for the purpose(s) shown below and rights incidental thereto, as granted in a document: Granted to: the State of California Purpose: public road Recording Date: May 4, 1934 Recording No: in Book 285 Page 461 of Official Records (AS SHOWN HEREON -ROW) ITEM #7 -Easement(s) for the purpose(s) shown below and rights incidental thereto as set forth in a document: Purpose: public highway Recorded: in Book 284 Page 38 of Official Records (AS SHOWN HEREON -ROW) ITEM #8 -Easement(s) for the purpose(s) shown below and rights incidental thereto, as granted in a document: Granted to: the County of San Diego Purpose: public road Recording Date: November 3, 1943 Recording No: as Instrument No. 72791 in Book 1586 Page 149 of Official Records (AS SHOWN HEREON) ITEM #10 -Easement(s) for the purpose(s) shown below and rights incidental thereto, as granted in a document: Granted to: County of Son Diego Purpose: road Recording Dote: January 16, 1947 Recording No: in Book 2334 Page 44 of Official Records (AS SHOWN HEREON) ITEM #11 -Easement(s) for the purpose(s) shown below and rights incidental thereto, as granted in a document: Granted to: San Diego Gas & Electric C0mpany Purpose: Public utilities Recording Date: October 19, 1948 Recording No: in Book 2985 Page 145 of Official Records (AS SHOWN HEREON) TITLE REPORT NOTES 11°55• I N 84'38'07" E 79.59' \ N 82'43'47" E 10.00' \ \ \ \ \ I \ \ \ LJGHTING FRAME-~--+==-TOP OF TOWER 70.8' AGL " • 0 0 71.3' AGL "~-+-~"~--UGHTING FRAME 68.4' AGL \ L=39.57' R=1050.00' .C,. =2'09'34" \ OF PTR SEE DETAIL SHEET LS3 \ \ I I I I / I \ \,,,,// _lJ \ < -\\ \ \ \ \ \ \ \ ARMY AND NAVY ACADEMY APN: 203-054-33-00 SEE ITEM #5 OF PTR \; \ VICINITY MAP SEE ITEM #19 OF PTR /\( / "' / / \:\ \ SEE ITEMS 8/10"' \ \ OF PTR v ~ 34·02•59~ \ \ \ 4.03' \ OVERALL SITE PLAN SEE ITEM /14 OF PTR SCALE: 80 1 "=80' LIGHTING FRAME------CC:=::--TOP OF TOWER 80.6' AGL 81.1' AGL --+-~--LIGHTING FRAME 78.2' AGL .+..----TOP OF TELEPHONE CABINET 15.7' AGL BOTTOM OF TELEPHONE CABINET-----lll 1 O' AGL GROUND LEVEL= 50' SOUTHWEST LIGHTPOLE GROUND LEVEL= 41.7' LIGHT POLE DETAIL NORTHEAST LIGHTPOLE ··>. .-• c \~~:;Mfia• ~;;: - 40 0 80 TITLE REPORT NOTES CONTINUED: ITEM #12 -Easement(s) for the purpose(s) shown below and rights incidental thereto, as granted in a document: Granted to: San Diego Gas & Electric Company Purpose: Public utilities Recording Date: October 25, 1951 Recording No: in Book 4273 Page 11 of Official Records (AS SHOWN HEREON) ITEM #18 -Easement(s) for the purpose(s) shown below and rights incidental thereto, as delineated on or as offered for dedication on Mop/Plat: Parcel Map No. 21046 Purpose: public street and public utility (AS SHOWN HEREON) ITEM #19 -Easement(s) for the purpose(s) shown below and rights incidental thereto, as granted in a document: Granted to: City of Carlsbad Purpose: access and public utility Recording Date: June 7, 203 Recording No: 2013-0359780 of Official Records (AS SHOWN HEREON) END OF EASEMENTS **ALL PLOTTABLE EASEMENTS AS DESCRIBED IN SAID TITLE REPORT ARE SHOWN HEREON AND DO NOT CROSS THE PROPOSED LEASE AREA EXCEPT FOR ITEM #8/10 WHICH IS AN ABANDONED ROAD." "THE PROPOSED LEASE AREA (AS SHOWN HEREON) IS NOT SITUATED ON ANY PLOTTABLE EASEMENT SHOWN ON SAID TITLE REPORT." ASPH BC EC ELCB ELTR FNCP LP NG PS RFPA RTOP SDINL SW TC TRTP2 TW VG ---x LEGEND LEGEND These standard symbols will be found in the drawing. -e-BULLARD lii'iil IRRIGATION VALVE -J:)-LIGHT POLE LIGHT WALL FOUND MONUMENT STORM DRAIN INLET TREE PALM ASPHALT SURFACE BOTTOM OF CURB EDGE OF CONCRETE ELECTRICAL CABINET ELECTRICAL TRANSFORMER FENCE TOP LIGHT POLE TOP GROUND SPOT ELEVATION PAINT STRIPING ROOF PARAPET ROOF TOP STORMDRAIN INLET SIDEWALK TOP OF CURB TREE TOP PALM WALL TOP V-GUTTER BOUNDARY LINE CENTERLINE MISC. PROPERTY LINE MISC. TIE LINE RIGHT -OF-WAY LINE EASEMENT LINE FENCE LINE 1) This is not a boundary survey. This is a specialized topographic mop. The property lines and easements shown hereon are from record information as noted hereon. Floyd Surveying, Inc. translated the topographic survey to record information using the two found monuments shown hereon. No title research was performed by Floyd Surveying. 2) Any changes made to the information on this pion, without the written consent of Floyd Surveying relieves Floyd Surveying of any an~ all liability. 3) These drawings & specifications are the property & copyright of Floyd Surveying & shall not be used on any other work except by agreement with the Surveyor. Written dimensions shall take preference over scaled & shall be verified on the job site. Any discrepancy shall be brought to the notice of the Surveyor prior to commencement of any work. 4) Field survey completed on NOVEMBER 18, 2014. NOTES ARCHITECTURE .. .. PLANNING WILLll'li'i M. □OOTH. ARCHITECT J\O □ERT J_ SlJ1'11l.EZ. ARCHITECT P.O.0OX 465< C/11\LSBAD, CA 9'2018 (760) 434-tl474 • ver1··11i1111on •• ~1n1111mm11m111111111100001· WI REL ES s 15505 SAND CANYON AVENUE IRVINE, CA 92618 BUILDING 'D' 1ST. FLOOR PREPARED BY: DAF CHECKED BY: DAF APPROVED BY: DAF -IJ \'. 2. DATE REVISIONS 11/21/14 SITE SURVEY 3/06/16, BOUNDARY i ' FLOYD SURVEYING 34006 GALLERON STREET TEMECULA, CA 92592 OFFICE: (949) 200-0626 EMAIL: fsi@floydsurveying.com SITE NAME CARLSBAD STATE STREET SITE NUMBER SITE ADDRESS 2605 CARLSBAD BOULEVARD CARLSBAD, CA 92008 SHEET TITLE SITE SURVEY GENERAL INFORMATION SHEET NUMBER LS1 SEE LIGHTPOLE DETAIL ON SHEET LS1 SOUTHWEST RT□';;,_ FNCP3 55.43 \ S\,15 \ 51.17 Tl,/ 53.81 -- lllYXl @61 NG / 51.31 V X A -- ~ ""1 X ARMY AND NAVY ACADEMY APN: 203-054-33-00 S\,14 48.65 S\,15 48.64 ~ 48.42 NG 150.44 X X -- X X -- '------------~:SEE ITEMS 8/10 OF P1R "-- 47.86 FNCP4-GATE 55,02 p " '\. '&> ~ 48.15 '\. i X ~ 48.88 NG ~CP 4ITTl1l' 54.98 - ----~ , r LP 7 68.78 NG 149.69 \ ---x ---x 's---X ------,_ __ N 89"07'24" W 513.57" TC 53.29 BC 52.67 48.21 + " PS 48.34 " PS2 " 47.66 " " PS 48.39 p 48.45 " EC6 41.84 " " \ EC4 PC 50.94 " " PS 47.62 ~ VG2 47,50 SDINL 47.40 ELTR-D213281 --j.. 50.15 / BC8 42.22 43.79 43,38 C2 4 01 " / / DETAIL SITE PLAN 2.41 ASPH -'42.18 PS3 42.92 BC5 42.83 PS3 ~ / ,,-,+;;CP5-GA TE / 51.78 /-----------;?<; TC 47.46 "BC 46.94 " -- SEE ITEM #18 OF Pffi --r / / / \>----1s/ Se,'<' ,, ~ / SCALE: 10 5 0 10 1 "=10' -------------- 11°55• ASPH BC EC ELCB ELTR FNCP LP NG PS RFPA RTOP SDINL SW TC TRTP2 TW VG ---x LEGEND LEGEND These standard symbols will be found in the drawing. -e-BULLARD .;.;i IRRIGATION VALVE ~ LIGHT POLE A LIGHT WALL @ FOUND MONUMENT STORM DRAIN INLET TREE PALM ASPHALT SURFACE BOTTOM OF CURB EDGE OF CONCRETE ELECTRICAL CABINET ELECTRICAL TRANSFORMER FENCE TOP LIGHT POLE TOP GROUND SPOT ELEVATION PAINT STRIPING ROOF PARAPET ROOF TOP STORMDRAIN INLET SIDEWALK TOP OF CURB TREE TOP PALM WALL TOP V-GUTTER BOUNDARY LINE CENTERLINE MISC. PROPERTY LINE MISC. TIE LINE RIGHT-OF-WAY LINE EASEMENT LINE FENCE LINE 1) This is not a boundary survey. This is a specialized topographic map. The property lines and easements shown hereon are from record information as noted hereon. Floyd Surveying, Inc. translated the topographic survey to record information using the two found monuments shown hereon. No title research was performed by Floyd Surveying. 2) Any changes made to the information on this plan, without the written consent of Floyd Surveying relieves Floyd Surveying of any and all liability. 3) These drawings & specifications are the property & copyright of Floyd Surveying & shall not be used on any other work except by agreement with the Surveyor. Written dimensions shall take preference over scaled & shall be verified on the job site. Any discrepancy shall be brought to the notice of the Surveyor prior to commencement of any work. 4) Field survey completed on NOVEMBER 18, 2014. NOTES ~RCHITECTcRE ■■ ■■ PLAlNING WILLIAM M. BOO7 H. ARCHITECT f\O0ER";' J_ SUAREZ. f1fl.Cf-l:TECT ?.0. D0X 4651. CM\~$8AD. CA 9'2018 (760) 43L-8474 15505 SAND CANYON AVENUE IRVINE, CA 92618 BUILDING "D' 1ST. FLOOR PREPARED BY: DAF CHECKED BY: DAF APPROVED BY: DAF ./..I. \'. 2. DATE 11/21/14 3/06/16 REVISIONS SITE SURVEY BOUNDARY FLOYD SURVEYING 34006 GALLERON STREET TEMECULA, CA 92592 OFFICE: (949) 200-0626 EMAIL: fsi@floydsurveying.com ~ 1!17 ~~ '/§ David A. Floyd ~ . a..: - SITE NAME CARLSBAD STATE STREET SITE NUMBER SITE ADDRESS 2605 CARLSBAD BOULEVARD CARLSBAD, CA 92008 SHEET TITLE SITE SURVEY GENERAL INFORMATION SHEET NUMBER LS2 ) . /~SEE I1EM #11 // I OFPTR I I I I I I I I I I I I I I I I I I I I I I I I \ \ \ \ \ \ \ \ \ \ \ \ \ I I I I I I I I I I I 1I--~SEE I1EMS 8/10 OF PTR I I I I 1- 1 I \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ ·~ ~ NG ·. 74233 RT□P4 56.27 ARMY AND NA VY ACADEMY -RT□P :J4. APN: 203-054-33-00 RTOP3 54,78 RTDP20 .,. 60,17 RTDP20 . /, 60,21 · '\RTOP2 52.94 EC6 42.52 T'w7 ~ 43~; 1 ~ 42,50 S'w5 42.78 SEE I1EMS 8/10 OF PTR ' DETAIL SITE PLAN SEE LIGHT POLE DETAIL SHEET LS1 NORTHEAST SCALE: 10 1"=10' 5 + 0 10 trss· ASPH BC EC ELCB ELTR FNCP LP NG PS RFPA RTOP SDINL SW TC TRTP2 TW VG ---x LEGEND LEGEND These standard symbols will be found in the drawing. -e--BULLARD liii>l IRRIGATION VALVE * LIGHT POLE • LIGHT WALL @ FOUND MONUMENT STORM DRAIN INLET TREE PALM ASPHALT SURFACE BOTTOM OF CURB EDGE OF CONCRETE ELECTRICAL CABINET ELECTRICAL TRANSFORMER FENCE TOP LIGHT POLE TOP GROUND SPOT ELEVATION PAINT STRIPING ROOF PARAPET ROOF TOP STORMDRAIN INLET SIDEWALK TOP OF CURB TREE TOP PALM WALL TOP V-GUTTER BOUNDARY LINE CENTERLINE MISC. PROPERTY LINE MISC. TIE LINE RIGHT -OF-WAY LINE EASEMENT LINE FENCE LINE 1) This is not a boundary survey. This is a specialized topographic map. The property lines and easements shown hereon are from record information as noted hereon. Floyd Surveying, Inc. translated the topographic survey to record information using the two found monuments shown hereon. No title research was performed by Floyd Surveying. 2) Any changes made to the information on this plan, without the written consent of Floyd Surveying relieves Floyd Surveying of any and all liability. 3) These drawings & specifications are the property & copyright of Floyd Surveying & shall not be used on any other work except by agreement with the Surveyor. Written dimensions shall take preference over scaled & shall be verified on the job site. Any discrepancy shall be brought to the notice of the Surveyor prior to commencement of any work. 4) Field survey completed on NOVEMBER 18, 2014. NOTES ARCHITECTURE ■■ ■■ PLA~NING WILLIAM M_ GOOCH_ Ai'\C~ITECT RODE RT J su,nEz IIRCH,TECT ? 0 DO:< 4651. Ct'1RL5Dl1D. CA 9'2018 (760) 43~-8~7~ 'lllr ,1111111111, 11 ••'' 111 llfllilllllllillll 111 ll[Ullllillllllllllilll l~[tt!IUllllllillilllllilllllllll ■ ver1·1'111on ,1111llloom111111111111m111111111 W/ R ELES S 15505 SAND CANYON AVENUE IRVINE, CA 92618 BUILDING 'D' 1ST. FLOOR PREPARED BY: DAF CHECKED BY: DAF APPROVED BY: DAF -1-1- \'. 2. I DATE 11/21/14 3/06/16 REVISIONS SITE SURVEY BOUNDARY FLOYD SURVEYING 34006 GALLERON STREET TEMECULA, CA 92592 OFFICE: (949) 200-0626 EMAIL: fsi@floydsurveying.com SITE NAME CARLSBAD STATE STREET SITE NUMBER SITE ADDRESS 2605 CARLSBAD BOULEVARD CARLSBAD, CA 92008 SHEET TITLE SITE SURVEY GENERAL INFORMATION SHEET NUMBER LS3