ORDINANCE NO. 8057
AN ORDINANCE OF THE CITY OF CARLSBAD ADOPTING 1970
EDITION OF UNIFORM PLUMBING CODE AND PROVIDING
PENALTIES FOR VIOLATION THEREOF.
The City Council of the City of Carlsbad, California, does
rdain as follows:
e
?e International Association of Plumbing and Mechanical Officials
5 hereby adopted by reference as the plumbing code of the City of
arlsbad except for the following changes, additions and amendments
hich shall supercede the provisions of said code:
The 1970 edition of the Uniform Plumbing Code copyrighted by
A. Section 1.1 is amended to read as follows:
"SECTION 1.1 - Administrative Authority and Assistants.
henever the term "Administrative Authority" is used in this code
t shall be construed to mean the Director of Building and Housing
r his authorized representatives".
B. SECTION 1.2 - ASSISTANTS. Whenever the term "Assistants"
s used in this code it shall be construed to mean deputy inspector
r other persons authorized to act for the Director of Building and
iousing" .
C. Section 1.3 is amended to read as follows:
"SECTION 1.3 - DEPARTMENT HAVING JURISDICTION. Unless other-
vise provided for by law, the office of adninistrative authority
hall be part of the Building and Housing Department".
D. The words "single family dwelling" as used in sub-para-
raph C of Section 1.10 are amended to read "single or two-family
welling. I'
E. The Schedule of Fees on page 6a is amended to read as
'ollows :
SCHEDULE OF FEES
'or issuing each permit $ 3.50
I
2
3
4
5
6
7
a
9
10
II
12
13
14
15
16
17
1E
14
2c
21
2'2
22
24
2E
2E
-27
2€
25
3c
31
3:
0 0
For each plumbing fixture or trap or set of fixtures on
one trap (including water, drainage piping and backflow
protection thereof)
For each building sewer and each trailer park sewer
Mobilhome Park drainage system, per lot or inlet
Rain Water Systems, per drain
For each cesspool
For each private sewage disposal system
For each water heater and or vent
For each gas piping system of one to five outlets
1.5
5.00
3.00
2.00
5.00
10.00
1.50
1.50
For each gas piping system of six or more, per outlet .30
For each industrial waste pre-treatment interceptor,
including its trap and vent, excepting kitchen type grease interceptors functioning as fixture traps 1.00
For installation, alteration or repair of water piping
and/or water treating equipment 1.50
For repair or alteration of drainage or vent piping 1.50
For each lawn sprinkler system on any one meter, including
backflow protection devices thereof 2.00
For vacuum breakers or backflow protective devices on tanks, vats, etc., or for instaliation on unprotected plumbing fixtures including necessary water piping, one ~~ to five 2.00
Over five, each .30
All reinspection fees 5.00
Failure to obtain permit prior to inspection 10.00
F. Section 1.15 is hereby added thereto to read as follows:
"SECTION 1.15 RE-INSPECTION. In the event work must be inspected
more than one time, a reinspection fee in the amount of $5.00 for
each reinspection shall be charged, and no further inspection of
the work shall be performed until the reinspection fee has been
paid.
G. Section 401 thereof is amended to read as follows:
"SECTION 401 - MATERIALS.
(a) Drainage pipes shall be cast iron, lead, copper,
brass, or other approved material bearing a smooth and uniform
bore.
1
2
3
4
5
8
9
10
11
12
13
14
15
16
17
1E
1s
2c
21
22
2:
24
2E
2c
2!
3(
3:
3
4
(b) Drainage fittings shall be of cast iron, lead, copper,
rass or other approved materials having a smooth interior waterway
f the same diameter of the piping served, and a11 such fittings
hall conform to the type of pipe used.
.. Add subsection (J) which reads:
An approved type cleanout fitting, acceptable to the adminis-
.rative authority, installed outside of a building at the lower
!nd of a building drain may extend 4 inches above grade or terminat
.n an approved concrete box installed approximately flush with the
:urrounding grade. A maximum extension of 24 inches will be allow-
:d on a single riser. For depths requiring a riser in excess of
!4 inches an approved two way, two riser cleanout shall be used.
1. Add Section 911 - Public toilet room Requirements to read:
Every toilet room for the use of the public at a public
jathering place or food handling establishments, stores, shops,
factories, canneries, or other commercial or industrial establish-
nents, or schools, shall have a tile, sealed cement or other
ipproved non absorbent floor and shall be equipped with a properly
installed floor drain.
T. Add subparagraph (e) to Section 1004 to read:
"no galvanized steel or galvanized wrought iron water piping
shall be installed or on the ground under any building or structure
K. Appendixs A,B.C.D.F. and G. are adopted as part of the plumbins
code of the City of Carlsbad.
L. Ordinance No. 8053 is hereby repealed.
M.
of a misdemeanor.
which any violation of this code occurs or continues, shall be
deemed to constitute a separate offense,
Any person who violates any provision hereof shall be guilty
Each separate day or any portion thereof during
This ordinance shall take effect and be in force on the
thirty-first day from and after its adoption.
1
1
1
a
1
7
1
1
1
:
# 6
I i
t 1
I
32 1
The City Clerk of the City of Carlsbad is hereby directed
o cause this ordinance to be published once in the Carlsbad
ournal, a newspaper published and of general circulation in
aid City of Carlsbad.
Introduced at a regular meeting of the City Council of
he City of Carlsbad, California heldNOVember 16th , 1971 and
hereafter PASSED, APPROVED, AND ADOPTED at a regular meeting of
aid City Council held Becember 7th , 1971, by the following vote
.o wit:
;YES: Cmn. Dunne, NcComas, Jardine, Castro and Lewis.
lOES : None.
iBSENT : None.
iTTEST :
U