ORDINANCE NO. NS - 717
AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF
CARLSBAD, CALIFORNIA, AMENDING TITLE 18, CHAPTER
18.16.080, BY THE ADDITION OF SECTION 609.11 TO THE
CARLSBAD MUNICIPAL CODE TO AMEND BY REFERENCE THE
UNIFORM PLUMBING CODE, 2001 EDITION TO REQUIRE
INSTALLATION OF BYPASS TEE FOR RECYCLED WATER SHUT
DOWN TEST.
The City Council of the City of Carlsbad, California, does ordain as follows:
SECTION 1 : The City Council finds that unique circumstances require certain amendments to
the Uniform Plumbing Code. The amendments set forth in this ordinance are reasonably
necessary because of the local climate, which includes low rainfall and periods of drought. It
has become necessary to expand the use of recycled water throughout the city in order to
conserve potable water. Cross-connection testing is required by State law as well as by
California Regional Water Quality Control Board, San Diego Region Order Number 2001 -352,
which is the Master Reclamation Permit for the Carlsbad Municipal Water District.
SECTION 2: That Title 18, Chapter 18.16 of the Carlsbad Municipal Code is amended by
the addition of Section18.16.080 to read as follows:
18.1 6.80 Section 609.12 is added to the Uniform Plumbing Code to read:
On the effective date of this Ordinance, all new buildings where recycled water will be used for
irrigation shall install on the building supply pipe a bypass tee for recycled water cross-connection
shut down testing. The bypass tee shall be constructed of copper and the size shall match the
building supply pipe size approved for the building. The bypass tee shall be connected to the
building supply pipe above ground and before the pressure regulator at a point just before it
enters the building. Both end connections to the building supply pipe shall be made using a union.
A bronze full port straight ball valve with handle shall be installed on the inlet side of the bypass
tee for the building supply pipe, and sized to match the inlet tee. A bronze full port straight ball
valve with tee-head and padlock wing shall be installed on the side inlet tee, which shall be
threaded with a male hose thread adapter to match the building supply pipe size. The work shall
be in conformance with Engineering Standard Drawing W35. All shut down tests using the bypass
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
tee shall be conducted with a backflow prevention device to reduce potential for contamination of
the potable water system.
EFFECTIVE DATE: This ordinance shall be effective thirty (30) days after its adoption and
the City Clerk, City of Carlsbad, shall certify to the adoption of this ordinance and cause it to be
published at least once in a newspaper of general circulation in the City of Carlsbad within fifteen
(15) days after its adoption.
INTRODUCED AND FIRST READ at a regular meeting of the Carlsbad City Council held
on the 21st day of September, 2004; and thereafter
PASSED, APPROVED AND ADOPTED at a regular meeting of the Carlsbad City Council
held on the 12th day of October , 2004 by the following vote, to wit:
AYES: Council Members Lewis, Finnila, Kulchin, Hall, and Packard
ATTEST:
Karen R. Kundtz, Assistant City Clerk
APPROVED AS TO FORM AND LEGALITY
n
q11-
R. BALL, City Attorney
/O f 3. C, cf;