Loading...
HomeMy WebLinkAboutBergelectric Corporation; 2019-03-27; PWM19-730GSRECORDED REQUESTED BY CITY OF CARLSBAD AND WHEN RECORDED PLEASE MAIL TO: City Clerk City of Carlsbad 1200 Carlsbad Village Drive Carlsbad, California 92008 DOC# 2019-0234554 111111111111 lllll 1111111111111111111111111111111111111111111111111 IIII Jun17,2019 11:12AM OFFICIAL RECORDS Ernest J Dronen burg, Jr., SAN DIEGO COUNTY RECORDER FEES $0 00 (SB2 Atkins $0 00) PAGES 1 Space above this line for Recorder's use. PARCEL NO: NOTICE OF COMPLETION Notice is hereby given that: 209-050-26-00 1. The undersigned is owner of the interest or estate stated bel°"~ i~hS,p~operty hereinafter described. 2. The full names of the undersigned are City of Carlsbad, a municipalGor-ron... +. ::.,, · 3. The full address of the undersigned is 1200 Carlsbad Village Drive, Carlsbad, California 92008. 4. The nature of the title of the undersigned is: In fee. 5. A work or improvement on the property hereinafter described was completed on June 4, 2019. 6. The name of the contractor for such work or improvement is Berg Electric Corp. 7. The property on which said work or improvement was completed is in the City of Carlsbad, County of San Diego, State of California, and is described as follows: Project No. PWM19-730GS, Project Name: Mobile Command Center Electric Panel. 8. The street address of said property is 2540 Orion Way, Carlsbad, CA 92010, in the City of Carlsbad. VERIFICATION OF CITY CLERK I, the undersigned, say: I am the City Clerk of the City of Carlsbad, 1200 Carlsbad Village Drive, Carlsbad, California, 92008; the City Manager of said City on JV n e / a 2o_Jj_, accepted the above described work as completed and ordered that a Notice of Completion be filed. I declare under penalty of perjury that the foregoing is true and correct. Executed on Jllrie 15 , 20___!_1, at Carlsbad, California. Hect~r G0 rt1e 2 __LJ.&,,.~~~=+--J-4:.µ~ ci-l'-1 c 1e 1J.t ~ d( BARBARA ENGLESON V City Clerk Q:IPublic Works\General Services\Agreements & Contracts\Berg Electric\Mobile Command Center Electric Panel -PWM19-730GSINOC\2.NOC -Mobile Command Center Electric Panel -PWM19-730GS.docx CITY OF CARLSBAD ACCEPTANCE OF PUBLIC IMPROVEMENTS COMPLETION OF PUBLIC IMPROVEMENTS Berg Electric Corp. has completed the contract work required for PWM19-730GS -Mobile Command Center Electric Panel. City forces have inspected the work and found it to be satisfactory. The work consisted of: IMPROVEMENTS VALUE Provide Electrical Shore Power service to MCC $18,840 stationed at Fire Station #5. CERTIFICATION OF COMPLETION OF IMPROVEMENTS John M~~~~1anager Date CITY MANAGER'S ACCEPTANCE OF PUBLIC IMPROVEMENTS The construction of the above described contract is deemed complete and hereby accepted. The City Clerk is hereby authorized to record the Notice of Completion and release the bonds in accordance with State Law and City Ordinances. The City of Carlsbad is hereby directed to commence maintaining the above described improvements. ~ ScottCha Date APPROVED AS TO FORM: CELIA BREWER, City Attorney By CJ~ Deputy City Attorney Q.\Public Works\General Services\Agreements & Contracts\Berg Electnc\Mobile Command Center Electric Panel -PWM19-730GS\NOCl3 API -Mobile Command Center Electric Panel -PWM19-730GS.docx PWM19-730GS Mobile Command Center Electric Panel Page 1 of 11 City Attorney Approved 9/27/16 CITY OF CARLSBAD MINOR PUBLIC WORKS CONTRACT MOBILE COMMAND CENTER ELECTRIC PANEL This agreement is made on the ______________ day of _________________________, 2019, by the City of Carlsbad, California, a municipal corporation, (hereinafter called "City"), and Bergelectric Corporation, a California corporation whose principal place of business is 650 Opper Street, Escondido, CA 92029 (hereinafter called "Contractor"). City and Contractor agree as follows: DESCRIPTION OF WORK. Contractor shall perform all work specified in the Contract documents for the project described by these Contract Documents (hereinafter called "Project"). PROVISIONS OF LABOR AND MATERIALS. Contractor shall provide all labor, materials, tools, equipment, and personnel to perform the work specified by the Contract Documents unless excepted elsewhere in this Contract. CONTRACT DOCUMENTS. The Contract Documents consist of this Contract, exhibits to this Contract, Contractor's Proposal, the Plans and Specifications, the General Provisions, addendum(s) to said Plans and Specifications, and all proper amendments and changes made thereto in accordance with this Contract or the Plans and Specifications, all of which are incorporated herein by this reference. When in conflict, this Contract will supersede terms and conditions in the Contractor’s proposal. LABOR. Contractor will employ only skilled workers and abide by all State laws and City of Carlsbad Ordinances governing labor. GUARANTEE. Contractor guarantees all labor and materials furnished and agrees to complete the Project in accordance with directions and subject to inspection approval and acceptance by: Ron Haugland (City Project Manager) WAGE RATES. The general prevailing rate of wages for each craft or type of worker needed to execute the Contract shall be those as determined by the Director of Industrial Relations pursuant to Sections 1770, 1773 and 1773.1 of the Labor Code. Pursuant to Section 1773.2 of the Labor Code, a current copy of the applicable wage rates is on file in the Office of the City Engineer. Contractor shall not pay less than the said specified prevailing rates of wages to all workers employed by him or her in execution of the Contract. Contractor shall be responsible for insuring compliance with provisions of section 1777.5 of the Labor Code and section 4100 et seq. of the Public Contracts Code, "Subletting and Subcontracting Fair Practices Act." The City Engineer is the City's "duly authorized officer" for the purposes of section 4107 and 4107.5. The provisions of Part 7, Chapter 1, of the Labor Code commencing with section 1720 shall apply to the Contract for work. A contractor or subcontractor shall not be qualified to bid on, be listed in a bid proposal, subject to the requirements of Section 4104 of the Public Contract Code, or engage in the performance of any contract for public work, unless currently registered and qualified to perform public work pursuant to Section 1725.5. This project is subject to compliance monitoring and enforcement by the Department of Industrial Relations. Contractor and any subcontractors shall comply with Section 1776 of the California Labor Code, which generally requires keeping accurate payroll records, verifying and certifying payroll records, and making them available for inspection. Contractor shall require any subcontractors to comply with Section 1776. DocuSign Envelope ID: 978C6515-20FA-44DE-8D52-ABDC51857691 27th March PWM19-730GS Mobile Command Center Electric Panel Page 2 of 11 City Attorney Approved 9/27/16 FALSE CLAIMS. Contractor hereby agrees that any contract claim submitted to the City must be asserted as part of the contract process as set forth in this agreement and not in anticipation of litigation or in conjunction with litigation. Contractor acknowledges that California Government Code sections 12650 et seq., the False Claims Act, provides for civil penalties where a person knowingly submits a false claim to a public entity. These provisions include false claims made with deliberate ignorance of the false information or in reckless disregard of the truth or falsity of the information. The provisions of Carlsbad Municipal Code sections 3.32.025, 3.32.026, 3.32.027 and 3.32.028 pertaining to false claims are incorporated herein by reference. Contractor hereby acknowledges that the filing of a false claim may subject the Contractor to an administrative debarment proceeding wherein the contractor may be prevented from further bidding on public contracts for a period of up to five years and that debarment by another jurisdiction is grounds for the City of Carlsbad to disqualify the Contractor or subcontractor from participating in contract bidding. Signature: ___________________________________ Print Name: ___________________________________ REQUIRED INSURANCE. The successful contractor shall provide to the City of Carlsbad, a Certification of Commercial General Liability and Property Damage Insurance and a Certificate of Workers’ Compensation Insurance indicating coverage in a form approved by the California Insurance Commission. The certificates shall indicate coverage during the period of the contract and must be furnished to the City prior to the start of work. The minimum limits of liability insurance are to be placed with California admitted insurers that have a current Best's Key Rating of not less than "A-:VII"; OR with a surplus line insurer on the State of California’s List of Approved Surplus Line Insurers (LASLI) with a rating in the latest Best’s Key Rating Guide of at least “A:X”; OR an alien non-admitted insurer listed by the National Association of Insurance Commissioners (NAIC) latest quarterly listings report. Commercial General Liability Insurance of Injuries including accidental death, to any one person in an amount not less than……..$1,000,000 Subject to the same limit for each person on account of one accident in an amount not less than ….…$1,000,000 Property damage insurance in an amount of not less than……..$1,000,000 Automobile Liability Insurance in the amount of $1,000,000 combined single limit per accident for bodily injury and property damage. In addition, the auto policy must cover any vehicle used in the performance of the contract, used onsite or offsite, whether owned, non-owned or hired, and whether scheduled or non- scheduled. The automobile insurance certificate must state the coverage is for “any auto” and cannot be limited in any manner. The above policies shall have non-cancellation clauses providing that thirty (30) days written notice shall be given to the City prior to such cancellation. The policies shall name the City of Carlsbad as an additional insured. The full limits available to the named insured shall also be available and applicable to the City as an additional insured. WORKERS’ COMPENSATION AND EMPLOYER’S LIABILITY. Workers’ Compensation limits as required by the California Labor Code. Workers’ Compensation will not be required if Contractor has no employees and provides, to City’s satisfaction, a declaration stating this. BUSINESS LICENSE. The Contractor and all subcontractors are required to have and maintain a valid City of Carlsbad Business License for the duration of the contract. DocuSign Envelope ID: 978C6515-20FA-44DE-8D52-ABDC51857691 Alan J. Mashburn, CEO, Secretary PWM19-730GS Mobile Command Center Electric Panel Page 3 of 11 City Attorney Approved 9/27/16 INDEMNITY. The Contractor shall assume the defense of, pay all expenses of defense, and indemnify and hold harmless the City, and its officers and employees, from all claims, loss, damage, injury and liability of every kind, nature and description, directly or indirectly arising from or in connection with the performance of the Contract or work; or from any failure or alleged failure of Contractor to comply with any applicable law, rules or regulations including those related to safety and health; and from any and all claims, loss, damages, injury and liability, howsoever the same may be caused, resulting directly or indirectly from the nature of the work covered by the Contract, except for loss or damage caused by the sole or active negligence or willful misconduct of the City. The expenses of defense include all costs and expenses including attorneys’ fees for litigation, arbitration, or other dispute resolution method. JURISDICTION. The Contractor agrees and hereby stipulates that the proper venue and jurisdiction for resolution of any disputes between the parties arising out of this agreement is San Diego County, California. Start Work: Contractor agrees to start within twenty (20) working days after receipt of Notice to Proceed. Completion: Contractor agrees to complete work within sixty (60) working days after receipt of Notice to Proceed. CONTRACTOR’S INFORMATION. Bergelectric Corporation 650 Opper Street (name of Contractor) 85046 (street address) Escondido, CA 92029 (Contractor’s license number) C-10, A,B,C-7 2/28/21 (city/state/zip) 760-746-1003 (license class. and exp. date) 1000000328 (telephone no.) 760-746-0675 (DIR registration number) 6/30/19 (fax no.) khendry@bergelectric.com (DIR registration exp. date) (e-mail address) /// /// /// /// /// /// /// DocuSign Envelope ID: 978C6515-20FA-44DE-8D52-ABDC51857691 PWM19-730GS Mobile Command Center Electric Panel Page 4 of 11 City Attorney Approved 9/27/16 AUTHORITY. The individuals executing this Agreement and the instruments referenced in it on behalf of Contractor each represent and warrant that they have the legal power, right and actual authority to bind Contractor to the terms and conditions of this Agreement. CONTRACTOR, BERGELECTRIC CORPORATION, a California corporation CITY OF CARLSBAD, a municipal corporation of the State of California By: By: (sign here) Paz Gomez, Public Works Director as authorized by the City Manager (print name/title) By: (sign here) (print name/title) If required by City, proper notarial acknowledgment of execution by Contractor must be attached. If a corporation, Agreement must be signed by one corporate officer from each of the following two groups: Group A Group B Chairman, President, or Vice-President Secretary, Assistant Secretary, CFO or Assistant Treasurer Otherwise, the corporation must attach a resolution certified by the secretary or assistant secretary under corporate seal empowering the officer(s) signing to bind the corporation. APPROVED AS TO FORM: CELIA A. BREWER, City Attorney BY: _____________________________ Deputy City Attorney DocuSign Envelope ID: 978C6515-20FA-44DE-8D52-ABDC51857691 Ron Wood, Executive Vice President Alan J. Mashburn, CEO, Secretary PWM19-730GS Mobile Command Center Electric Panel Page 5 of 11 City Attorney Approved 9/27/16 EXHIBIT A LISTING OF SUBCONTRACTORS BY GENERAL CONTRACTOR Set forth below is the full name and location of the place of business of each sub-contractor whom the Contractor proposes to subcontract portions of the Project in excess of one-half of one percent of the total bid, and the portion of the Project which will be done by each sub-contractor for each subcontract. NOTE: The Contractor understands that if it fails to specify a sub-contractor for any portion of the Project to be performed under the contract in excess of one-half of one percent of the bid, the contractor shall be deemed to have agreed to perform such portion, and that the Contractor shall not be permitted to sublet or subcontract that portion of the work, except in cases of public emergency or necessity, and then only after a finding, reduced in writing as a public record of the Awarding Authority, setting forth the facts constituting the emergency or necessity in accordance with the provisions of the Subletting and Subcontracting Fair Practices Act (Section 4100 et seq. of the California Public Contract Code). If no subcontractors are to be employed on the project, enter the word "NONE." SUBCONTRACTORS Portion of Project to be Subcontracted Business Name and Address DIR Registration No. License No., Classification & Expiration Date % of Total Contract Total % Subcontracted: _______________ The Contractor must perform no less than fifty percent (50%) of the work with its own forces DocuSign Envelope ID: 978C6515-20FA-44DE-8D52-ABDC51857691 Cable Pipe & Leak 3.7% 860181, C-36, 6/30/2019 1% Coring 478960, A, C-61, 9/30/2019 1000002917 GPR Scan 4.7% 1000010206 Casper Company PWM19-730GS Mobile Command Center Electric Panel Page 6 of 11 City Attorney Approved 9/27/16 EXHIBIT B Mobile Command Center Electric Panel Overview: Contractor to provide all materials, tools and labor to add a 200A breaker in existing switchgear, run conduit and conductors to feed a new 200A “Panel C”, and install 100A single phase SO cord drop to feed the Mobile Command Center (MCC). All work to conform to National and California Electrical Codes, and the plans included in Exhibit “C”. Scope of Work: 1) Install new 200A, 65KAIC circuit breaker in existing switchboard main switchgear per plans in Exhibit “C”. This is a reconditioned/tested breaker matching this older switchgear SO number. 2) Install feeder conduit and conductors from main switchgear to new Panel C location per plans in Exhibit “C”. All conduit to be installed immediately below netting. 3) Install new Panel C, 200A, 120/208V, 10Kaic, 3 Phase, 4-wire, per plans in Exhibit “C”. 4) Install 100A, 120/208V, Single Phase, 3-wire, branch circuit from new Panel C to proposed location for mobile command center hook up per plans in Exhibit “C”. 5) Includes SO Cord drop and 100A, 3-pole, 4-wire, connector. Notes: - Contractor shall submit a construction schedule to the City’s project manager within five (5) working days after the issuance of a Notice to Proceed. - Contractor to submit a written request for outage to make connections at main switch gear. Request shall be submitted to the City’s project manager no less than fourteen (14) days prior to the proposed outage date. - Contractor recognizes that the facility in which the proposed work to be done is a fully operational fire station. Consideration for the operations of the department shall be taken during the project duration. Contractor’s daily work schedules shall be coordinated with Fire Department staff to prevent disruptions of operations. Any delays in the project as a result of Fire Department operations shall be considered circumstances out of the control for both City and Contractor. Neither party will be held responsible for damages resulting in a delay of the project. JOB QUOTATION ITEM NO. UNIT QTY DESCRIPTION PRICE 1 LS 1 Fire Station #5 Panel C & Equipment Circuit for Mobile Command Center $18,840 TOTAL* $18,840 *Includes taxes, fees, expenses and all other costs. DocuSign Envelope ID: 978C6515-20FA-44DE-8D52-ABDC51857691 PWM19-730GS Mobile Command Center Electric Panel Page 7 of 11 City Attorney Approved 9/27/16 EXHIBIT C Engineering Design Documents for Fire Station #5 Panel Add DocuSign Envelope ID: 978C6515-20FA-44DE-8D52-ABDC51857691 ADDRESS: PROJECT:FIRE STATION NO. 5 PANEL ADD 2540 ORION WAY, CARLSBAD, CA 92121EEOR STAMP350 Pauma PlaceEscondido, CA 92029TEL: 760.658.6098Electrical Engineers, Inc.12-18-18PLAN CHECK01-24-19OWNER COMMENTST0.01TITLE SHEETSHEET INDEXPROJECT TEAMPROJECT DATAFIRE STATION NO. 5PANEL ADD2540 ORION WAY,CARLSBAD, CA 92121NO SCALET0.01 TITLE SHEETE0.01 COVER SHEETE3.01 FIRST FLOOR POWER PLANE8.01 SINGLE LINE DIAGRAMBRIAN BACARDICITY OF CARLSBAD405 OAK AVECARLSBAD, CA 92008TEL: 760.434.2944EMAIL:brian.bacardi@carlsbadca.govELECTRICALCONTRACTOR:(PERMIT HOLDER)NBUILDING CODES:2016 CALIFORNIA BUILDING CODE (CBC)2016 CALIFORNIA ELECTRICAL CODE (CEC)2016 CALIFORNIA MECHANICAL CODE (CMC)2016 CALIFORNIA PLUMBING CODE (CPC)2016 CALIFORNIA ENERGY CODE2016 CALIFORNIA FIRE CODE (CFC)2016 CALIFORNIA GREEN BUILDING STANDARDS CODE (CAL GREEN CODE)SCOPE OF WORKMARK THOMASMTA ELECTRICAL ENGINEERS350 PAUMA PLACEESCONDIDO, CA 92029TELEPHONE: 760-658-6098EMAIL: mark@mtaee.comELECTRICALENGINEER:BRIAN BACARDITELEPHONE: 760-434-2944CONTACT INFORMATION:FIRE HOUSEBUILDING USE:209-050-26-00APN #:DALE CHRISTIAN1748 WEST KATELLASTRUCTURALENGINEER:SITE MAPNO SCALEVICINITY MAP(APN# 209-050-26-00)NPROJECT CONSISTS OF INSTALLING ONE NEW 200AMP120/208V, 3 PHASE 4 WIRE PANEL IN THE APPARATUSFLOOR TO SERVE THE MOBILE STATION CHARGER.FARADAY AVENUEIMPALA DRIVEORION WAYEL CAMINO REALORION STREET PALMER WAYEL CAMINO REALRUTHERFORD ROADFARADAY AVENUESALK AVENUEPALOMAR AIRPORT ROADFARADAY AVENUEEL FUERTE STREETPRIESTLY DRIVEEL CAMINO REALORION WAYAREA OF WORKPWM19-730GSExhibit "C"DocuSign Envelope ID: 978C6515-20FA-44DE-8D52-ABDC51857691 ADDRESS: PROJECT:FIRE STATION NO. 5 PANEL ADD 2540 ORION WAY, CARLSBAD, CA 92121EEOR STAMP350 Pauma PlaceEscondido, CA 92029TEL: 760.658.6098Electrical Engineers, Inc.12-18-18PLAN CHECK01-24-19OWNER COMMENTS1. CONTRACTOR TO OBTAIN PERMISSION FOR ACCESS TO THE SITE FROM THEOWNER OR DESIGNATED OWNER REPRESENTATIVE TO VISIT THE SITE INCLUDINGALL AREAS OF WORK PRIOR TO BID. CONTRACTOR TO BE FAMILIARIZED WITHEXISTING CONDITIONS, VERIFY SAID CONDITIONS, DIMENSIONS, AND ROUTINGSPRIOR TO START OF CONSTRUCTION. REPORT ANY DISCREPANCIES TO OWNER /ARCHITECT / ENGINEER WITHIN 48 HOURS OF DISCREPANCIES FOUND.2. CONTRACTOR SHALL CONFIRM ACCURACY OF PANEL BOARD INFORMATIONPRIOR TO START OF WORK. REPORT ANY DISCREPANCIES TO OWNER /ARCHITECT / ENGINEER WITHIN 48 HOURS OF DISCREPANCIES FOUND.3. ALL WORK SHOWN IS NEW UNLESS OTHERWISE NOTED.4. ALL AREAS OUTSIDE THE SCOPE OF WORK SHALL BE PROTECTED IN PLACE ANDREMAIN INTACT, U.O.N.5. CONTRACTOR TO COORDINATE WITH OWNER ANY SHUTDOWN OF ELECTRICALEQUIPMENT WITH 7 DAYS NOTIFICATION. CONTRACTOR TO INCLUDE OFF HOURSIN PRICING FOR THIS WORK.6. ALL ELECTRICAL MATERIAL AND EQUIPMENT SHALL BE NEW BEARING A ULLISTING OR ACCEPTABLE NRTL LISTING FROM THE LOCAL AREA JURISDICTION.7. CONTRACTOR SHALL COMPLY WITH THE CURRENT VERSION OF THE CALIFORNIAELECTRICAL CODE 2016, STATE, LOCAL CODES, ORDINANCES, AND REGULATIONS.8. WORK SHALL BE PERFORMED IN A SAFE MANNER AND NOT DISTURB OR AFFECTEXISTING BUILDING UTILITIES, OCCUPANTS, OR FINISHES WITHOUT PRIOR NOTICEAND APPROVAL FROM OWNER.9. ALL CONDUIT RUN SHALL BE FIELD COORDINATED, LOCATE CONDUITS CLEAR OFOTHER TRADES, DOOR ACCESS, OR OTHER OBSTRUCTIONS. COORDINATECONDUIT RUNS WITH OTHER TRADES PRIOR TO COMMENCEMENT OF WORK.10. RUN ALL CONDUITS CONCEALED IN CEILING SPACES, U.O.N. TO BE SURFACEMOUNTED. ALL CONDUIT PATHWAYS MUST MAINTAIN 6 INCHES CLEAR OFSOURCES OF HEAT, SUPPORT CONDUITS FROM STRUCTURE.11. ALL BRANCH CIRCUITS TO BE PROVIDED WITH SEPARATE GREEN GROUNDINSULATED CONDUCTOR.12. ALL BRANCH CIRCUITS TO BE PROVIDED WITH SEPARATE WHITE NEUTRALINSULATED CONDUCTOR. SHARED NEUTRAL IS ACCEPTABLE IF COMMON HANDLETIE CIRCUIT BREAKER ARE UTILIZED TO SIMULTANEOUSLY DISCONNECT ALLUNGROUNDED CONDUCTORS PER NEC 210.4(B).13. PROVIDE IDENTIFICATION TAGS FOR ALL WIRING, INSTALL TAGS AT END OF RUNS,INTERMEDIATE PULL BOXES, JUNCTION BOXES, CABINETS, ETC.14. BRANCH CIRCUIT VOLTAGE DROP NOT TO EXCEED 3% FROM PANEL BOARDSOURCE.15. LABEL ALL CIRCUIT BREAKERS IN ALL ELECTRICAL DISTRIBUTION PANELS ANDSWITCHBOARDS. PROVIDE TYPE WRITTEN CIRCUIT DIRECTORY CARDS FOR ANYPANEL BOARD HAVING CIRCUIT MODIFICATIONS.16. PROVIDE P-TOUCH LABELS ON ALL NEW OUTLETS, RACKS, PLUG MOLD, ANDSWITCHES.17. ALL CONDUITS PENETRATING ELECTRICAL/MECHANICAL SPACES OF RATEDWALLS SHALL BE SEALED AND FIRE STOPPED.18. ALL ELECTRICAL PENETRATIONS INTO COOLER OR FREEZER UNITS SHALL BESEALED PER SECTION 300-7 OF THE NEC.19. ALL BRANCH CIRCUIT CONDUCTORS TO BE THHWN-2/THHN-2 INSULATION,COPPER MATERIAL.GENERAL PROJECT NOTESABBREVIATIONS AND DESCRIPTIONSA / AMPAMPEREABV ABOVEADA AMERICAN WITH DISABILITIES ACTAFAMPERE FRAME, AMPERE FUSEAFF / A.F.F. ABOVE FINISH FLOORAFG, A.F.G. ABOVE FINISH GRADEAWG AMERICAN WIRE GAUGEAIC / A.I.C. AMPERE INTERRUPTING CAPACITYASAMPERE SWITCHATAMPERE TRIPATS AUTOMATIC TRANSFER SWITCHAVG AVERAGEBKR BREAKERBLDG BUILDINGBRBRANCHCCONDUITCATV CABLE TELEVISIONCBCIRCUIT BREAKERCBC CALIFORNIA BUILDING CODECEC CALIFORNIA ELECTRIC CODECFC CALIFORNIA FIRE CODECIRC / CKT CIRCUITCLCENTER LINECLG CEILINGCO / C.O. CONDUIT ONLYCOMM COMMUNICATIONSCSFM CALIFORNIA STATE FIRE MARSHALLCTCONTROL TRANSFORMERCONN CONNECTEDCPT CONTROL POWER TRANSFORMERCTR CENTERDET DETAILDIST DISTRIBUTIONDPDISTRIBUTION PANEL(D)DEMOLISHDISC DISCONNECTDWG DRAWINGDIADIAMETERDIMDIMENSIONEMT ELECTRICAL METALLIC TUBINGEPEXPLOSION PROOFEMEMERGENCYEQP EQUIPMENT(E)EXISTINGELEC ELECTRICALEMS EMERGENCY MANAGEMENT CONTROL SYSTEMENTELECTRICAL NON-METALLIC TUBINGEPO / E.P.O EMERGENCY POWER OFFEFEXHAUST FANEGEQUIPMENT GROUNDEOL END OF LINE RESISTORFACP FIRE ALARM CONTROL PANELFLFLOORFATC FIRE ALARM TERMINAL CABINETFAFIRE ALARMFLAFULL LOAD AMPSFT / ' FEETFINFINISHG / GND GROUNDGFCI GROUND FAULT CIRCUIT INTERRUPTERGFP GROUND FAULT PROTECTIONGEC GROUNDING ELECTRODE CONDUCTORH / HGT HEIGHTHOA HAND OFF AUTOHPHORSEPOWERHACR HEATING AIR CONDITIONING REFRIGERATIONHVAC HEATING, VENTILATING AND AIR CONDITIONINGHIDHIGH INTENSITY DISCHARGEICINTERCOMIDFINTERMEDIATE DISTRIBUTION FRAMEIN / " INCHESIMC INTERMEDIATE METAL CONDUITIPINTERNET PROTOCOLIGISOLATED GROUNDJB / JBOX JUNCTION BOXKAIC KILOAMPERE INTERRUPTING CAPACITYKVKILOVOLTKVA KILOVOLT AMPEREKWKILOWATTKWHKILOWATT HOURLTG / LTS LIGHTINGLVLOW VOLTAGELFLINEAR FEETKCMIL / MCM THOUSAND CIRCULAR MILSMAX MAXIMUMMDFMAIN DISTRIBUTION FRAMEMECH MECHANICALMHMANHOLEMTD MOUNTEDMTG MOUNTINGMIN MINIMUMMOCP MAXIMUM OVERCURRENT CIRCUIT PROTECTIONMCA MINIMUM CIRCUIT AMPERESMCB MAIN CIRCUIT BREAKERMLO MAIN LUGS ONLYMMETERMVMERCURY VAPORMCC MOTOR CONTROL CENTERMFR MANUFACTURERNCNORMALLY CLOSEDNFPANATIONAL FIRE PROTECTION ASSOCIATIONNICNOT IN CONTRACTNONORMALLY OPENNO. / #NUMBERNEC NATIONAL ELECTRICAL CODENEMA NATIONAL ELECTRICAL MFR ASSOCIATIONNFNON-FUSEDNLNIGHT LIGHTNTS NOT TO SCALEOCON CENTEROFCI OWNER FURNISH, CONTRACTOR INSTALLEDPPOLEPBPULL BOXPFPOWER FACTORPAPUBLIC ADDRESSPH / øPHASEPNL PANELPRIMARY OVER 600 VOLTSPCPHOTOCELLPDU POWER DISTRIBUTION UNITPROVIDE FURNISH, INSTALL AND/OR CONNECTPTPOTENTIAL TRANSFORMERPVC POLYVINYL CHLORIDEREQD REQUIREDREQT(S) REQUIREMENT(S)RMROOMRMS ROOT MEAN SQUARERGS RIGID GALVANIZED STEEL CONDUITRECEPT RECEPTACLESHT SHEETSWSWITCHSWBD SWITCHBOARDSTC SIGNAL TERMINAL CABINETSCC SHORT CIRCUIT CURRENTSFD SMOKE FIRE DAMPERSECONDARY 600 VOLTS AND LESSSQSQUARETEL TELEPHONETYP TYPICALTCTIMECLOCKTEL/DAT TELEPHONE AND DATATVTELEVISIONTVSS TRANSIENT VOLTAGE SURGE SUPPRESSIONULUNDERWRITERS LABORATORIESUON / U.O.N. UNLESS OTHERWISE NOTEDUPS UNINTERRUPTIBLE POWER SUPPLYVVOLTAGEVAVOLT AMPERESVDVOLTAGE DROPVAVVARIABLE AIR VOLUMEWWATTAGE OR WIREWPWEATHERPROOFWAP WIRELESS ACCESS POINTXFMRTRANSFORMERX / (X) EXISTINGXL / (XL) EXISTING TO BE RELOCATEDXR / (XR) EXISTING TO BE REMOVEDXN / (XN) EXISTING NEW LOCATION%ZPERCENTAGE IMPEDANCEWTWEIGHTWHWATER HEATERVFDVARIABLE FREQUENCY DRIVEUGPS UNDERGROUND PULL SECTIONTEMPTEMPERATURE OR TEMPORARYSWGR METAL CLAD SWITCHGEARSPEC SPECIFICATIONSREC RECESSEDREFRIG REFRIGERATORQTY QUANTITYPWRPOWERN / NEUTNEUTRALLBS POUNDSKSKNEE SPACEHRHOUR OR HOME RUNHZHERTZGCGENERAL CONTRACTORGALV GALVANIZEDCUCOPPERCCTV CLOSED CIRCUIT TELEVISIONALALUMINUMACALTERNATING CURRENTA/CAIR CONDITIONINGDCDIRECT CURRENTEAEACHEXO DISCONNECT SWITCHECELECTRICAL CONTRACTOREDEXTRA-DUTYWRWEATHER RESISTANTCONTROL LEGENDSURFACE MOUNTED SPST SWITCH MOUNTED AT +48" AFF TO TOP OFBOX U.O.NFLUSH MOUNTED SINGLE POLE STANDARD TOGGLE SWITCHMOUNTED AT +48" AFF TO TOP OF BOX U.O.N. LETTERING INDICATESQUANTITY OF SWITCHES AND DEVICES TO BE CONTROLLED.XXD = DIMMING SWITCHK = KEYED SWITCHP = PILOT LIGHT SWITCHR = MOMENTARY CONTACT SWITCHT = TIMER SWITCH3 = THREE WAY SWITCHFLUSH INFRARED WALL OCCUPANCY SENSOR SINGLE BUTTONMOUNTED AT +48" AFF TO TOP OF BOX U.O.NOCFLUSH INFRARED WALL OCCUPANCY SENSOR DUAL BUTTONMOUNTED AT +48" AFF TO TOP OF BOX U.O.NOCabSURFACE INFRARED WALL OCCUPANCY SENSOR SINGLE BUTTONMOUNTED AT +48" AFF TO TOP OF BOX U.O.NSURFACE INFRARED WALL OCCUPANCY SENSOR DUAL BUTTONMOUNTED AT +48" AFF TO TOP OF BOX U.O.NabOCOCXXU = ULTRA SONIC OCCUPANCY SENSORDT = DUAL TECHNOLOGY OCCUPANCY SENSOROCCEILING MOUNTED INFRARED OCCUPANCY SENSOROCFLUSH MOUNTED OVERRIDE SWITCH STATION MOUNTED AT +48" AFFTO TOP OF BOX U.O.N. BUTTON CONFIGURATION AS NOTED PERFLOOR PLANSURFACE MOUNTED OVERRIDE SWITCH STATION MOUNTED AT +48"AFF TO TOP OF BOX U.O.N. BUTTON CONFIGURATION AS NOTED PERFLOOR PLANPHOTOCELL MOUNTED AND ORIENTATED AS NOTED ON FLOOR PLANOOPCDLCEILING MOUNTED DAY LIGHT SENSORSINGLE LINE LEGENDELECTRONIC METERING UNITCURRENT TRANSFORMERPOTENTIAL TRANSFORMERDRAWOUT CIRCUIT BREAKERAMP FRAMEAMP TRIPPOLE CONFIGURATIONELECTRONIC TRIP FUNCTIONSFUSETRANSFORMER100AF100AT3LSIGFUSED SWITCHAMP SWITCHAMP FUSEPOLE CONFIGURATION100AS100AF3CIRCUIT BREAKERAMP FRAMEAMP TRIPPOLE CONFIGURATIONELECTRONIC TRIP FUNCTIONS100AF100AT3LSIGGROUNDING ELECTRODEENCLOSED CIRCUIT BREAKERAMP FRAMEAMP TRIPPOLE CONFIGURATIONELECTRONIC TRIP FUNCTIONS100AF100AT3LSIGCNORMALLY OPEN CONTACTNORMALLY CLOSED CONTACTCOILSHUNT TRIPSTSOLID STATESSFEEDER TAGXXXXAUTOMATIC TRANSFER SWITCHPACKAGE ENGINE GENERATORPANEL BOARDPANELHL1TRANSIENT VOLTAGE SURGE SUPPRESSIONTVSSM+-+-STRINGER INVERTER+-PHOTOVOLTAIC PANEL (PV PANEL)FLUSH MOUNTED HALF HOT DUPLEX RECEPTACLE MOUNTED AT +15"AFF TO BOTTOM OF BOX U.O.NXXHALF SHADED WIRING INDICATES CONTROLLEDRECEPTACLE PER TITLE 24 SECTION 130.5(d)POWER LEGENDFLUSH MOUNTED DUPLEX RECEPTACLE MOUNTED AT +15" AFF TOBOTTOM OF BOX U.O.NFLUSH MOUNTED QUAD RECEPTACLE MOUNTING HEIGHT TOBOTTOM OF BOX PER ARCHITECT ELEVATIONSURFACED MOUNTED DUPLEX RECEPTACLE MOUNTED AT +15" AFFTO BOTTOM OF BOX U.O.NSURFACE MOUNTED QUAD RECEPTACLE MOUNTED AT +15" AFF TOBOTTOM OF BOX U.O.NFLUSH MOUNTED SINGLE RECEPTACLE MOUNTED AT +15" AFF TOBOTTOM OF BOX U.O.NSURFACE MOUNTED SINGLE RECEPTACLE MOUNTED AT +15" AFF TOBOTTOM OF BOX U.O.NCEILING MOUNTED DUPLEX RECEPTACLECEILING MOUNTED QUAD RECEPTACLEFLUSH FLOOR BOX WITH DUPLEX RECEPTACLEFLUSH FLOOR BOX WITH QUAD RECEPTACLEFLUSH FLOOR BOX WITH COMBINATION DUPLEX RECEPTACLE ANDDATA OUTLETFLUSH FLOOR BOX WITH COMBINATION QUAD RECEPTACLE ANDDATA OUTLETFIRE RATED POKE THRU WITH DUPLEX RECEPTACLEFIRE RATED POKE THRU WITH QUAD RECEPTACLEFIRE RATED POKE THRU WITH DUPLEX RECEPTACLE AND DATAOUTLETFIRE RATED POKE THRU WITH QUAD RECEPTACLE AND DATAOUTLETXXFLUSH MOUNTED SPECIAL NEMA CONFIGURATION RECEPTACLEMOUNTED AT +15" AFF TO BOTTOM OF BOX U.O.NSURFACE MOUNTED SPECIAL NEMA CONFIGURATION RECEPTACLEMOUNTED AT +15" AFF TO BOTTOM OF BOX U.O.NXX-XXXXX-XXXFLUSH MOUNTED JUNCTION BOX MOUNTED AT +15" AFF TO BOTTOMOF BOX U.O.NSURFACE MOUNTED JUNCTION BOX MOUNTED AT +15" AFF TOBOTTOM OF BOX U.O.NFLUSH FLOOR MOUNTED JUNCTION BOXCEILING MOUNTED JUNCTION BOXJJJJGFCIIGSHACGROUND FAULT CIRCUIT INTERRUPTERISOLATED GROUNDSURGE SUPPRESSORHORIZONTAL MOUNTEDMOUNT ABOVE COUNTER PERARCHITECT ELEVATIONPROVIDED WITH INTREGRAL USBPORTSRECEPTACLE CONTROLLED PER TITLE24 2013 SECTION 130.5(d)CLOCK TYPE====CEILING MOUNTED SPECIAL NEMA CONFIGURATION RECEPTACLEXX-XXXFLOOR MOUNTED SPECIAL NEMA CONFIGURATION RECEPTACLEXX-XXX==RC=CFLUSH MOUNTED DUPLEX RECEPTACLE MOUNTING HEIGHT TOBOTTOM OF BOX PER ARCHITECT ELEVATIONSURFACED MOUNTED DUPLEX RECEPTACLE MOUNTED AT COUNTERLEVEL PER ARCHITECT ELEVATIONSURFACE MOUNTED QUAD RECEPTACLE MOUNTING TO BOTTOM OFBOX PER ARCHITECT ELEVATIONFLUSH MOUNTED QUAD RECEPTACLE MOUNTED AT +15" AFF TOBOTTOM OF BOX U.O.N=USBRECEPTACLE POWER PACK MOUNTED IN ACCESSIBLE CEILINGSPACE FOR AUTOMATIC CONTROL OF RECEPTACLE DEVICERCMEQUIPMENT LEGENDHEAVY DUTY NON-FUSED DISCONNECTHEAVY DUTY FUSED DISCONNECTMOTOR STARTER, HOA, AUX CONTACTS, CPT, PILOT LIGHTSCOMBINATION MOTOR STARTER, HOA, AUX CONTACTS, CPT, PILOTLIGHTS, WITH FUSED DISCONNECT SWITCHMECHANICAL EQUIPMENT TAGMOTOR RATED SWITCHSURFACE MOUNTED PANEL BOARD OR ELECTRICAL CABINETDISTRIBUTION SWITCHBOARD OR PANEL BOARDLIGHT FIXTURE DESIGNATIONLIGHTING BRANCH CIRCUITRELAY DESIGNATION IN LIGHTINGCONTROL PANELFLUSH MOUNTED PANEL BOARD OR ELECTRICAL CABINETVARIABLE FREQUENCY DRIVE. CONFIRM INTEGRAL DISCONNECTINGMEANS WITH MECHANICALF1HL1-13(R1)AHU1FVFDTTRANSFORMEREMERGENCY POWER OFF BUTTONEPOSFDSMOKE FIRE DAMPERMOTORSIGNAL LEGENDFLUSH MOUNTED TELEVISION OUTLET MOUNTED AT +15" AFF TOBOTTOM OF BOX U.O.NWIRELESS ACCESS POINTFLUSH MOUNTED TELECOM OUTLET MOUNTED AT +15" AFF TOBOTTOM OF BOX U.O.N. PROVIDE 1"C. TO ACCESSIBLE CEILINGSPACE WITH PULL STRING, U.O.N.SURFACE MOUNTED TELECOM OUTLET MOUNTED AT +15" AFF TOBOTTOM OF BOX U.ON. PROVIDE 1"C. TO ACCESSIBLE CEILINGSPACE WITH PULL STRING, U.O.N.CEILING MOUNTED TELECOM OUTLETPUSH BUTTONBUZZERBELLWALL MOUNTED SPEAKERCEILING MOUNTED SPEAKERTVWAPFLUSH FLOOR BOX WITH TELECOM OUTLETFIRE RATED POKE THRU WITH TELECOM OUTLETBBSSFLUSH MOUNTED WALL PHONE OUTLET MOUNTED AT +44" AFF TOTOP OF BOX U.O.NWSECURITY LEGENDALARM CONTACTELECTRIC DOOR STRIKEDOOR CONTACTREMOTE DOOR RELEASEELECTRONIC LOCKVIBRATION DETECTORCARD READERKEYPADACRKPGLASS BREAKGBMOTION SENSORMSESDCDRDOOR BREACH ALARMPANIC BUTTON / DURESS ALARMREQUEST TO EXITREXELECTRONIC HOLD OPENEHOELECTRONIC PANIC HARDWAREEPHELECTRONIC MAGNETIC LOCKEMLFIXED POSITION VIDEO CAMERAELVDDAPBPAN, TILT, ZOOM VIDEO CAMERAPTZPHOTOVOLTAIC LEGENDDC TO AC STRING INVERTERPOTENTIAL INDUCED DEGRATION (PID) ENERGY BALANCER CABINETPHOTOVOLTAIC MODULE PANEL (PV PANEL)PIDPHOTOVOLTAIC ARRAY (PV ARRAY)STRING NUMBER DESIGNATIONINVERTER NUMBER DESIGNATIONS#.#WIRING LEGENDRACEWAY EXPOSEDRACEWAY TURNED UPRACEWAY TURNED DOWNRACEWAY CAPPED AND STUBBED.PROVIDE PERMANENT GROUNDMARKER FOR UNDERGROUND INSTALLATIONSBRANCH CIRCUIT RACEWAY CONCEALED IN WALL OR CEILINGBRANCH CIRCUIT RACEWAY CONCEALED IN FLOOR ORUNDERGROUNDBRANCH CIRCUIT RACEWAY HOME RUN BACK TO ELECTRICALEQUIPMENT AS NOTEDL1-1BRANCH CIRCUIT RACEWAY WITH 3#12, 1#12N, 1#12GND, 3/4"C.MAXIMUM THREE BRANCH CIRCUITS PER HOME RUN, U.O.N.BRANCH CIRCUIT RACEWAY WITH 3#10, 1#10N, 1#10GND, 3/4"C.MAXIMUM THREE BRANCH CIRCUITS PER HOME RUN, U.O.N.#10CABLE TRAYPOINT OF CONNECTION TO EQUIPMENTBRANCH CIRCUIT RACEWAY TO BE DEMOLISHSURFACE MOUNTED WIRE MOLD RACEWAY SYSTEM.X = 1, 2 OR 3 CHANNEL RACEWAYWMXE0.01COVER SHEETDocuSign Envelope ID: 978C6515-20FA-44DE-8D52-ABDC51857691 KEYNOTES1APPROXIMATE LOCATION OF EXISTING ELECTRICAL EQUIPMENT.APPROXIMATE LOCATION OF NEW PANEL BOARD.ROUTE EXPOSED CONDUIT TIGHT TO CEILING OVER APPARATUS FLOOR SPACE.PROVIDE 20"X20"X6" NEMA 1 PULL BOX WITH HINGED COVER PLATE. MOUNT PULL BOX HIGHNEAR THE CEILING ROOF LINE.PROVIDE SO CORD WITH STRAIN RELIEF MOUNTED HIGH TO CEILING FOR MOBILE COMMANDCENTER, SINGLE PHASE 100A CONNECTION FED FROM NEW PANEL 'C'.CORE DRILL THROUGH WALL HIGH NEAR THE CEILING ROOF LINE TO DROP FEED TO NEWPANEL 'C', AND FOR FEED FROM NEW PANEL 'C' TO THE NEW MOBILE COMMAND CENTERCONNECTION.PROVIDE 20"X20"X6" NEMA 1 PULL BOX WITH HINGED COVER PLATE. MOUNT PULL BOX HIGHNEAR THE CEILING ROOF LINE. RUN FEED FROM NEW PANEL 'C' TO THE MOBILE CENTERCONNECTION THROUGH BOX.GENERAL NOTES1.SEE SHEET E8.01 FOR SINGLE LINE DIAGRAM, CONDUIT, AND CONDUCTOR SIZING.2.CONTRACTOR TO MAINTAIN CIRCUITRY CONTINUITY TO EXISTING SPACE OUTSIDE THISSCOPE OF WORK.3.CONDUIT RACEWAY TO BE EMT WITH COMPRESSION FITTINGS.4.FEEDER CONDUCTORS TO BE THWN-2/THHN-2 INSULATION, COPPER MATERIALS.2BEMBMSACATS111EMA24#3/0, 1#4 GND., 2-1/2"C13434556767SCALE:1FIRST FLOOR POWER PLAN1/8" = 1'-0"ADDRESS: PROJECT:FIRE STATION NO. 5 PANEL ADD 2540 ORION WAY, CARLSBAD, CA 92121EEOR STAMP350 Pauma PlaceEscondido, CA 92029TEL: 760.658.6098Electrical Engineers, Inc.12-18-18PLAN CHECK01-24-19OWNER COMMENTSE3.01FIRST FLOOR POWER PLANDocuSign Envelope ID: 978C6515-20FA-44DE-8D52-ABDC51857691 KEYNOTESPROVIDE NEW CIRCUIT BREAKER IN SPACE CIRCUIT POSITION. NEW CIRCUIT BREAKER TOMATCH EXISTING MANUFACTURER AND AIC VALUES.CONTRACTOR TO PROVIDE BREAKER MOUNTING HARDWARE AS REQUIRED FOR ACOMPLETE AND OPERATIONAL SYSTEM.EXISTING GROUNDING ELECTRODE TO REMAIN.GENERAL NOTES1.ALL ELECTRICAL DEVICE SHOWN ARE EXISTING TO REMAIN, U.O.N.2.ALL ELECTRICAL CONDUIT AND CONDUCTORS ARE EXISTING TO REMAIN, U.O.N.3.NEW ABOVE GROUND CONDUIT RACEWAY TO BE EMT WITH COMPRESSION FITTINGSFOR INTERIOR APPLICATIONS AND COMPRESSION RAIN TIGHT FITTINGS FOR EXTERIORAPPLICATIONS.4.NEW FEEDER CONDUCTORS TO BE THWN-2/THHN-2 INSULATION, COPPER MATERIAL.1EXISTINGSDG&EPADMOUNTTRANSFORMERSDG&E EXISTING12KV CIRCUITEXISTING SDG&E CONDUIT ANDCONDUCTORSM800AUGPSEXISTING MAIN SWITCHBOARD 'MS'800A, 120/208V, 3Ø 4W, 65KAICEXISTING 400A ATSNELEXISTING GENERATOR80 KW300AS300 AF3PAFATP4004003EXISTINGGNAFATP2002003ASAFP8008003JJNAFATP2002003EXISTINGPANELBEXISTINGPANELAEXISTINGPANELEMBEXISTINGPANELEMAEXISTINGFEEDEREXISTINGFEEDEREXISTING FEEDERNEWPANELCNEW4#3/0, 1#4 GND.2-1/2"C.AFATP20020031323EXISTING3CKT#KVA LOADTRIP/POLESBREAKERCIRCUIT DESCRIPTIONROOMMOUNTINGFED FROMNOTEABCCOND.FEEDER RACEWAY AND CONDUCTORSNEUTRALBUS AMPSVOLTSAICMAIN BKRLUGSMSELECTRIC & TELEPHONE ROOMFLOOREXISTINGUTILITY100%800208Y/120V 3P 4WSTANDARD80065,000200/319.22-1/2"C,3#3/0,#3/0N,#4G19.219.21200/317.52-1/2"C,3#3/0,#3/0N,#4G17.517.52400/324.64"C,3#600kcmil,#1/0G24.624.63200/302-1/2"C,3#3/0,#3/0N,#4G8.338.334CONN. KVACALC. KVACONN. KVACALC. KVATOTAL CONNECTED KVA BY PHASEBALANCED THREE PHASE AMPSHEATINGCONTINUOUSNONCONTINUOUSKITCHEN EQUIPNONCOIN/DIVERSETOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTING(100%)(125%)(100%)61.469.769.7002010020100000000557(N/A)(N/A)0020100201PANEL APANEL BPANEL EMBPANEL CLUGSMAIN BKRAICCIRCUIT DESCRIPTIONLOADKVACKTBKRCKT#CKT#LOADBKRCKTCIRCUIT DESCRIPTIONKVAROOMMOUNTINGFED FROMNOTEVOLTSBUS AMPSNEUTRALPANEL:APPARATUS FLOORSURFACE208Y/120V 3P 4W20010,000200STANDARDNEWMS100%Ca20/1020/1012b20/1020/1043c20/1020/1065a20/1020/1078b20/1020/10109c20/1020/101211a20/1020/101314b20/1020/101615c20/1020/101817a20/1020/101920b20/1020/102221c20/1020/102423a20/1020/102526b20/1020/102827c20/1020/103029a20/1020/103132b20/1020/103433c20/1020/103635a20/1020/103738b100/216.720/204039c | |4241PHASE BALANCE PERCENT: PHASE APHASE BPHASE CBALANCED THREE PHASE AMPSCONN. KVACALC. KVACONN. KVACALC. KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGTOTAL KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)46.30%150%150%16.716.7000000000016.7000016.700(N/A)(N/A)SPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPAREMOBILE COMMAND CENTER HOOKUPSPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPAREVOLTAGE DROP SCHEDULEDEVICEFEEDERVOLTAGE DROPWIRE SIZELENGTHBRANCH CIRCUITMAX VOLTAGE DROPWIRE SIZETOTAL VOLTAGEDROPMS0%(2)#600kcmil---0%C0.43%#3/0127'--0.43%FAULT CURRENT SCHEDULEDEVICEFAULTAIC RATINGL-N VOLTSUTILITYFAULTFED FROMDEVICEFAULTFEEDERSIZEX / 1000'R / 1000'LENGTHTRANSFORMERKVAZ%XR RATIOFAULT ATPRIMARYTOTALMOTORFAULTDIRECTLY CONNECTEDMOTOR LOADKVAFAULTMS42,00065,000120V42,000(2)#600kcmil0.01950.0115C9,09110,000120V9,091MS42,000#3/00.0420.077127'ADDRESS: PROJECT:FIRE STATION NO. 5 PANEL ADD 2540 ORION WAY, CARLSBAD, CA 92121EEOR STAMP350 Pauma PlaceEscondido, CA 92029TEL: 760.658.6098Electrical Engineers, Inc.12-18-18PLAN CHECK01-24-19OWNER COMMENTSSCALE:NONE1SINGLE LINE DIAGRAME8.01SINGLE LINE DIAGRAMDocuSign Envelope ID: 978C6515-20FA-44DE-8D52-ABDC51857691