HomeMy WebLinkAboutUS Filter Wastewater Group Inc; 2002-08-12; 3675 Part 5 of 5City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT 2) Internal Plunger: Stainless steel; Types 302,304 or 305. 3) Core Tube: Stainless steel; Types 302,304 or 305. 4) Plunger Spring: Stainless steel; Types 302, 304 or 305. 5) Cage Assembly: Stainless steel; Types 302,304 or 305. 6) Seats: PTFE. 7) Seals: PTFE. 8) Fasteners: Type 316 stainless steel. h. Manufacturers: 1) MAC, 6300 Series; 2) Or equal. 3. Designation: SV3. a. Description: Open-close valve for isolation service. b. Operating Conditions: Install where noted or shown. c. Design Requirements: 1) Enclosure: NEMA 4 rated. 2) Power Supply: 120 VAC, 60 Hz, single phase. 3) Coils: Class F. 4) Maximum Operating Pressure: 150 psig. d. End Connections: Socket fittings. e. Power Actuator: Solenoid actuated. f. Materials: 1) Body: PVC. 2) Seats: EPDM. 3) Seals: PTFE or EPDM. APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT 4) Fasteners: Type 316 stainless steel g. Manufacturers: 1) George Fischer, 199 Series; 2) Or equal. B. Butterfly Valves 1. Designation: BFV3 a. Description: Low pressure, general service process isolation valve in sizes up'to 12-inches. Valve shall be suitable for corrosive service conditions. b. Operating Conditions: Install where noted or shown. c. Design Requirements: 1) Body: Two piece design 2) Seats: Fully replaceable, covering all wetted portions of the valve body. Seats shall extend to the flange interface to provide sealing without the use of a gasket. Seats shall provide an internal seal with the disdshaft. 3) Disc and Stem: One-piece; investment cast; thin profile for improved cyclic service. 4) Maximum Operating Pressure: 150 psig. 5) Rated Operating Temperature: 73" F. d. End Connections: 1) Lugged, ANSI Class 150 standard drilling. 2) Wafer, for installation between ANSI Class 150 flanges. e. Actuator: Manual or power, as shown on the Drawings and Valve Schedules. f. Manual Actuators: 1) For 2-inch Valves: Lever actuator, 10-position with positive latching. 2) For Valves over 2-inches: Rotary manual actuator. IS100.Vnlver and Appurtcnaneer.dac 15100-13 APW 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT g. Materials: Body: Cast iron; ASTM A126 - Standard Specification for Gray Iron Castings for Valves, Flanges, and Pipe Fittings, Class B. Disc and Shaft: Stainless steel, Type 316; ASTM A351 - Standard Specification for Castings, Austenitic, Austenitic-Ferritic (Duplex) for Pressure-Containing Parts, Type CFSM. Seats: EPDM, food grade. Stem Seal: NBR or Buna-N. Stem Bushing: Nylon or acetal. Fasteners: Type 316 stainless steel. h. Manufacturers: 1) Keystone, Figure 990/920; 2) Bray, Series 20/21; 3) Ultraflo, Model 399/392. 2. Designation: BFV5 a. Description: Low pressure, general service process isolation valve in sizes up to 12-inches. Valve shall be suitable for corrosive service conditions in contact with chlorine solutions in excess of 50 ppm. b. Operating Conditions: Install where noted or shown. c. Design Requirements: Body: Two piece design. Seats: Fully replaceable, covering all wetted portions of the valve body. Seats shall extend to the flange interface to provide sealing without the use of a gasket. Seats shall provide an internal seal with the disc/shaft. Disc and Stem: One-piece; investment cast; thin profile for improved cyclic service. Maximum Operating Pressure: 150 psig. 15100-14 APRIL. 27,2001 City of Carlsbad MF EQUIPMENT PROCUREMENT Carlsbad Recycling Facility 5) Rated Operating Temperature: 73' F. d. End Connections: 1) Lugged, ANSI Class 150 standard drilling. 2) Wafer, for installation between ANSI Class 150 flanges. e. Actuator: Manual or power, as shown on the Drawings and Valve Schedules. f. Manual Actuators: 1) For 2-inch Valves: Lever actuator, IO-position with positive latching. 2) For Valves over 2-inches: Rotary manual actuator. g. Materials: 1) Body: Cast iron; ASTM A126 - Standard Specification for Gray Iron Castings for Valves, Flanges, and Pipe Fittings, Class B. 2) Disc and stem: PTFE molded over an investment cast stainless steel insert; 17-4 PH per ASTM A747 - Standard Specification for Steel Castings, Stainless, Precipitation Hardening, Type CB7Cu-1, heat treated. 3) Seats: PTFE faced EPDM, replaceable. 4) Seals: NBR or polyester. 5) Fasteners: Type 316 stainless steel. h. Manufacturers: 1) Keystone, Figure 990/920; 2) Bray, Series 20/21; 3) Ultraflo, Model 399/392. C. Ball Valves 1. Designation: BV2. a. Description: Three-piece stainless steel ball valve, in sizes up to 2-inches. 1SIOO.Vslwr and Appunensnser.doe 15100-15 APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT b. Operating Conditions: Install where noted or shown. c. Design Requirements: 1) Maximum Operating Pressure: 1000 psig. 2) Rated Operating Temperature: 200'F. d. End Connections: 1000 WOG, FNPT. e. Actuator: Manual, lever type, f. Materials: 1) Body: Stainless steel, Type 316; ASTM A276 - Standard Specification for Stainless Steel Bars and Shapes or ASTM A351 - Standard Specification for Castings, Austenitic, Austenitic-Femtic (Duplex) for Pressure-Containing Parts, Grade CF8M. 2) Ball: Type 316 stainless steel. 3) Stem: Type 316 stainless steel. 4) Seats: Reinforced PTFE. 5) Seals: Reinforced PTFE. g. Manufacturers: 1) Milwaukee; 2) Contromatics; 3) Or equal. 2. Designation: BV3. a. Description: Three-piece brass ball valve, in sizes up to 2-inches. b. Operating Conditions: Install where noted or shown. c. Design Requirements: 1) Maximum Operating Pressure: 600 psig. 2) Rated Operating Temperature: 200" F. 15100-16 APRIL 27,2001 City of carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCURFMEM d. End Connections: 600 WOG, conforming to MSS SP-110 - Ball Valves Threaded, Socket-Welding, Solder Joint, Grooved and Flared Ends. e. Actuator: Manual, lever type. f. Materials: 1) Body: Brass; ASTM B30 - Standard Specification for Copper Alloys in Ingot Form. 2) Ball: Hard Chrome plated brass ball, 3) Stem: Brass; ASTM B30 - Standard Specification for Copper Alloys ' in Ingot Form. 4) Seats: Glass reinforced Durafill. 5) Seals: PTFE. 6) Bolting: Type 316 stainless steel. g. Manufacturers: 1) Watts Series B-6000; 2) Or equal. D. Check Valves 1. Designation: BCV3. a. Description: Ball check valve integral to chemical injection quill; see equipment specification for requirements. 2. Designation: BCV4. a. Description: CPVC ball check valve in sizes up to 1 -inch. b. Operating Conditions: Install where noted or shown. c. Design Requirements: 1) Design Pressure: 150 psig. 2) Design Temperature: 73 "F. d. End Connections: Union pipe fittings. APW 27,2001 City of Carlsbad MF EQUIPMENT PROCUREMENT Carlsbad Recycling Facility e. Check Mechanism: Spring assisted ball. f. Materials: 1) Body: CPVC, normal impact class 23477-B, Type N, Grade 1, Schedule 80; ASTM Dl784 - Standard Specification for Rigid Poly(Viny1 Chloride) (PVC) Compounds and Chlorinated Poly(Viny1 Chloride) (CPVC) Compounds. 2) Ball: Same as body. 3) Spring: Type 316 stainless steel. 4) ' Seats: EPDM, food grade. 5) Seals: EPDM, food grade. g. Manufacturers: 1) Asahi/America Inc.; 2) &Equal. 3. Designation: DCV2. a. Description: Stainless steel diaphragm (disc) check valves in sizes up to 1- inch. b. Operating Conditions: Install where noted or shown. c. Design Requirements: 1) Design Pressure: 850 psig. 2) Design Temperature: 200 OF. d. End Connections: Wafer style for installation between ANSI Class 150 pipe flanges. e. Check Mechanism: Spring assisted disc. f. Materials: 1) Body: Martensitic stainless steel; ASTM A217 - Standard Specification for Steel Castings, Martensitic Stainless and Alloy, for Pressure- Containing Parts, Suitable for High-Temperature Service. I5loo.V.lw.ndAppurtcn.nccs.doc 15100-18 APRIL 27,2001 City of Carlsbad MF EQUIPMENT PROCUREMENT Carlsbad Recycling Facility 2) Disc: Stainless steel, Type 316; ASTM A167 - Standard Specification for Stainless and Heat-Resisting Chromium-Nickel Steel Plate, Sheet, and Strip. 3) Spring: Type 3 16 stainless steel. g. Manufacturers: 1) SpiraxlSarco, Model DCV2; 2) Or Equal. 4. Designation: SCV3. a. Description: Double-door, stainless steel wafer type check valve for general service in sizes up to 12-inches. b. Operating Conditions: Install where noted or shown. c. Design Requirements: 1) Maximum Operating Pressure: 275 psig. 2) Rated Operating Temperature: 150" F 3) Rated Valve Coefficient (CV): d. End Connections: Wafer style, to fit between ANSI Class 150 flanges. e. Check Mechanism: Dual spring-assisted swing plates. f. Materials: 1) Body: Type 316 stainless steel. 2) Plates: Type 316 stainless steel. 3) Shaft: Type 316 stainless steel. ISIW.V.lve*mdApp~nnnser.doe 15100-19 APRIL. 27,2001 city of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT 4) Seals: EPDM, full face, secured to the valve plates by Type 316 stainless steel clamp plates and fasteners; field replaceable. 5) Fasteners: Type 316 stainless steel. g. Manufacturers: 1) Techno, Model 505 1-3 16; 2) Mueller Steam Specialty, Model 72 Sure Check 1501b. ANSI; 3) Or equal. E. Diaphragm Valves 1. Designation: DPV5 a. b. C. d. e. f. Description: Chemical service, PVC weir type valve meeting MSS-SP-88 requirements. Operating Conditions: Install where noted or shown. Design Requirements: 1) Maximum Operating Pressure: 110 psig. 2) Rated Operating Temperature: 120' F End connections: Socket weld; or Flanged, flat face, ANSI Class 150 standard. Actuator: Manual handwheel, permanently lubricated, with clear stem cover and adjustable travel stop. Materials: Body: PVC. Bonnet: Polypropylene. Diaphragm: EPDM backed PTFE. Stem: Steel. Stem Bushing: Bronze. Compressor: Cast iron or PVDF. 15100-20 APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT 7) Tube Nut: Bronze or stainless steel. 8) Bonnet Seals: EPDM. 9) Bolting: Type 316 stainless steel. g. Manufacturers: 1) ITT Dia-Flo, Model 2436/2451; 2) ASAHYAmerica, Type 72lG 3) Or equal. F. Plug Valves 1. Designation: CTV4. a. Description: Hastelloy C eccentric plug valves for corrosive service conditions. b. Operating Conditions: Install where noted or shown. c. Design Requirements: 1) Maximum Operating Pressure: 275 psig. 2) Rated Operating Temperature: 150' F. d. End Connections: Flanged, ANSI Class 150. e. Actuator: Manual or power, as indicated on the Drawings or specified herein. f. Materials: 1) Body: Hastelloy C. 2) Packing: PTFE. 3) Plug Facing: Viton. 4) Bonnet: Hastelloy C. 5) Bolting: 18-8 stainless steel. g. Manufacturers: 15100.V.I~e1nndAppW~nssr.doc 15100-21 APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT 1) Dezurik, Model PEC; 2) Or equal. G. Gate Valves 1. Designation: GV2. a. Description: Bronze gate valves for process air service, in sizes up to 3- inches. b. Operating Conditions: Install where noted or shown. c. Design Requirements: 1) Maximum Operating Pressure: 300 psig. 2) Rated Operating Temperature: 150" F. d. End Connections: FNPT. e. Actuator: Manual, handwheel/chainwheel type. f. Materials: 1) Body: Bronze; ASTM B62 - Standard Specification for Composition Bronze or Ounce Metal Castings. 2) Wedge: Same as body. 3) Bonnet: Sameas body. 4) Stem: Silicon bronze; ASTM B584 - Standard Specification for Copper Alloy Sand Castings for General Applications and ASTM B875 - Standard Specification for Aluminum Diffusion Coating Applied by Pack Cementation Process. 5) Bonnet Ring and Gland: Brass; ASTM B16 - Standard Specification for Free-Cutting Brass Rod, Bar and Shapes for Use in Screw Machines. 6) Packing: Flexible graphite. 7) Handwheel: Ductile iron; ASTM A536 - Standard Specification for Ductile Iron Castings. 8) Bolting: Steel, zinc plated. ISIW.Vnlve0 and Appmnatxes.dw 1 5 100-22 APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT g. Manufacturers: 1) Walworth, Figure Wll; 2) Or equal. H. Air Relief Vavles 1. Designation: ARVl . a. Description: Pressure air release valves for the vacuum air removal system. b. Operating Conditions: Install where noted or shown. c. Design Requirements: 1) Operating Pressure: 10 psia. 2) Operating Temperature: 74 OF. d. End Connections: e. Materials: 1) Body: Cast iron. 2) Seat: Type 316 stainless steel. 3) Plunger: Type 316 stainless steel. 4) Fulcrum: Type 316 stainless steel. 5) Lever: Type 316 stainless steel. 6) Float: Type 316 stainless steel. 7) Fasteners: Type 3 16 stainless steel. f. Manufacturers: 1) Crispin Valves; 2) Or equal. I. Pressure Relief Valves 1. Designation: PRV4. 15100.V~lves and Appm-lemCCl.doc 15100-23 APRIL 27,2001 City of Carlsbad hfF EQUIPMENT PROCUREMENT Carlsbad Recycling Facility a. Description: Chemical injection line safety relief valve. Furnished by the chemical pump supplier-see equipment specification for requirements. 2. Designation: PRV5. a. Description: Pressure relief valves used in the compressed air system, b. Operating Conditions: Install where noted or shown. c. Design Requirements: 1) Design Operating Pressure: 150 psig. 2) Rated Operating Temperature: 450' F 3) Provide an external lever actuator for manual testing. 4) ASME code compliance required. d. End Connections: 1) Inlet: MNF'T. 2) Outlet: FNPT. e. Adjustable Range: 5 to 250 psig. f. Materials: 1) Body: Bronze. 2) Adjusting Nut and Stem: Bronze. 3) Spring: Steel, cadmium plated. g. Manufacturers: 1) McMaster-Cam, Series 4673K; 2) Or equal. 3. Designation: PRV6. a. Description: High capacity pressure relief valve for compressed air service. b. Operating Conditions: Install where noted or shown. 15100.VaI~ and Applmemneu.dos 1 5 100-24 APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQU~PMENT PROCUREMENT c. Design Requirements: 1) Design Operating Pressure: 150 psig. 2) Rated Operating Temperature: 400" F 3) Provide an external lever actuator for manual testing. 4) ASME code compliance required. d. End Connection: MNPT. e. Adjustable Range: 25 to 300 psig. f. Materials: 1) Body: Bronze. 2) Adjusting Nut and Stem: Bronze. 3) Spring: Steel, cadmium plated. g. Manufacturers: 1) F.C. Kingston Inc., Model 119C; 2) Or equal. J. Pressure RegulatingIControl Valves 1. Designation: BPR3. a. Description: Chemical injection line backpressure regulator. Furnished by the chemical pump supplier-see equipment specification for requirements. 2. Designation: PCV4. a. Description: General purpose regulators for compressed air service. b. Operating Conditions: Install where noted or shown. c. Design Requirements: 1) Maximum Inlet Pressure: 300 psig. 2) Maximum Operating Temperature: 175 OF. 15 1 00-25 APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT d. End Connections: FNPT. e. Adjustable Range: 5 to 125 psig. f. Materials: 1) Body: Aluminum. 2) Bonnet: Aluminum. 3) Bottom Plug: Aluminum. 4) Elastomers: Nitrile. g. Manufacturers: 1) Norgren, Type R17; 2) Or equal. 3. Designation: PCVS. a. b. C. d. e. f. Description: Relief type pilot regulator for pneumatic valve service. Operating Conditions: Install where noted or shown. Design Requirements: 1) Maximum Operating Pressure: 140 psig. 2) Maximum Operating Temperature: 120 OF. End Connections: FNPT. Adjustable Range: 5 to 100 psig. Materials: 1) Body: Aluminum. 2) Cover: Aluminum. 3) Piston: Aluminum. 4) Spring: Stainless steel. 5) Shaft: Stainless steel. 151W.Valves and Appwruncen.dos 15 100-26 APRIL 27,2001 city of Carlsbad MF EQUIPMENT PROCUREMENT Carlsbad Recycling Facility 6) Elastomers: NBR. g. Manufacturers: 1) SMC, Series VEX1; 2) Or equal. 4. Designation: PCV6. a. Description: Precision regulators for compressed air service. b. Operating Conditions: Install where noted or shown. c. Design Requirements: 1) Maximum Inlet Pressure: 145 psig. 2) Maximum Operating Temperature: 175 OF. d. End Connections: FNPT. e. Adjustable Range: 5 to 100 psig. f. Materials: 1) Body: Aluminum. 2) Bonnet: Aluminum. 3) Bottom Plug: Aluminum. 4) Elastomers: Nitrile. g. Manufacturers: 1) SMC, Series IR 200; 2) Or equal. 5. Designation: PCV7. a. Description: Dome loaded, pilot operated pressure regulating valve with internal bias spring for high capacity, compressed air service. b. Operating Conditions: Install where noted or shown. Is1W.V~Ives and App8mensnces.d.x 15100-27 APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT c. Design Requirements: 1) Maximum Inlet Pressure: 250 psig. 2) Maximum Operating Temperature: 175 "F. d. End Connections: ANSI flange. e. Adjustable Range: 20 to 200 psig. f. Materials: 1) Body: Cast iron. 2) Bonnet: Cast iron. 3) Diaphragm: Stainless steel, 17-4 PH, 3 ply. 4) Seat: Stainless steel. 5) Elastomers: Reinforced PTFE. g. Manufacturers: 1) Kaye & Mac Donald, Type IV; 2) Or equal. K. Automatic Drain Valves 1. Designation: ADVl . a. Description: Self-actuated automatic condensate drain valve for compressed air systems. b. Operating Conditions: Install where noted or shown. c. Design Requirements: 1) Capacity: 2 gallons per drain cycle at 100 psig. 2) Operating Pressure: 3 - 300 psig. 3) Operating Temperature: 35 - 120 OF. 4) Adjustable Timer Interval: 0.5 to 45 minutes. APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMEM 5) Adjustable Drain Cycle Time: 0.5 to 10 seconds. 6) Enclosure Rating: NEMA 4, minimum. d. End Connections: FNPT. e. Actuator: 1 15 VAC integral solenoid actuated. f. Materials: 1) Body: Forged brass. 2) Diaphragm: Viton. g. Manufacturers: 1) Deltech, Model ADV; 2) Or equal. L. Sample Valves 1. Designation: S1. a. Description: Two-piece I/4-inch PVC sample valve with hose fitting outlet. b. Operating Conditions: Install where noted or shown. c. Design Requirements: 1) Maximum Operating Pressure: 150 psig 2) Rated Operating Temperature: 70' F d. End Connections: 1) ValveBody: FNPTxFNPT 2) Inlet/Outlet Fittings: MNPT inlet with hose outlet, e. Actuator: Manual, graduated handle. f. Materials: 1) Body: PVC, Type I, Grade 1; ASTM Dl784 - Standard Specification for Rigid Poly(Viny1 Chloride) (PVC) Compounds and Chlorinated Poly(Viny1 Chloride) (CPVC) Compounds. 15100-29 APRIL 27.2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT 2) Ball: Same as body. 3) Stem: Same as body. 4) Seats: EPDM, replaceable. 5) Seals: EPDM. g. Manufacturers: 1) Hayward, Universal Stopcock; 2) Or equal. 2. Designation: S2. a. Description: Needle type stainless steel sample valve with hose fitting outlet. b. Operating Conditions: Install where noted or shown. c. Design Requirements: 1) Maximum Operating Pressure: 3,000 psig 2) Rated Operating Temperature: 200' F d. End Connections: MPT x hose. e. Actuator: Manual, graduated handle. f. Materials: 1) Body: Stainless steel, Type 316. 2) Ball: Same as body. 3) Stem: Same as body. 4) Seats: Kel-F. 5) Seals: PTFE. g. Manufacturers: 1) Parker CPI; 15100-30 APRIL 27,2001 City of carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT 2) Whitey, D Series; 3) Or equal. 2.04 INSTRUMENTATION AND CONTROLS A. Requirements 1. The MFEM shall coordinate with respective manufacturer’s of mechanical and electrical systems associated with the valves furnished to ensure all required functionality is incorporated and resolve any signal and control interface discrepancies. 2. Where required, the MFEM shall fiunish additional devices and interface components in accordance with requirements under Divisions 13 and 16. 2.05 SPARE PARTS A. Provide to the Engineer a list of all spare and replacement parts with individual prices and location where they are available. Prices shall remain in effect for a period of not less than one year after start-up and final acceptance. B. For additional spare parts requirements by system, see the detailed system specification sections following Section 11300. 2.06 SHOP PAINTING A. B. C. D. E. If not specified herein, coatings shall comply with the requirements of Section 09900. In case of a conflict, the requirements of this Section govern. If the manufacturer’s requirement is not to require finished coating on any interior surfaces, then manufacturer shall so state and no interior finish coating will be required, if acceptable to the Engineer. The exterior surface of various parts of valves, operators, floor-stands and miscellaneous piping shall be thoroughly cleaned of all scale, dirt, grease or other foreign matter and thereafter one shop coat of an approved rust-inhibiting primer shall be applied in accordance with the instructions of the paint manufacturer or other primer compatible with the finish coat provided. Unless otherwise noted, interior ferrous surfaces of all valves shall be given a fusion bonded epoxy coating per Section 09900. Ferrous surfaces obviously not to be painted shall be given a shop coat of grease or other suitable rust-resistant coating. Mounting surfaces shall be especially coated with a rust preventative. ISIOO.Vnlvcr and Appppuncmmer.dae 15100-31 APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT F. Special care shall be taken to protect uncoated items and plastic items, especially fkom environmental damage. 2.07 SPECIAL TOOLS A. Provide all special tools required for normal maintenance. Tools shall be packaged in a steel case, clearly and indelibly marked on the exterior to indicate equipment for which tools are intended. 2.08 LUBRICANTS A. Provide all lubricants required for equipment startup and initial operations. PART 3 - EXECUTION 3.01 A. B. C. D. E. DELIVERY AND INSTALLATION All valves and appurtenances shall be installed per these Specifications, the manufacturer's instructions and approved shop drawings in the locations shown, true to alignment and rigidly supported. Any damage to the above items shall be repaired to the satisfaction of the Engineer before they are installed. Install all brackets, extension rods, guides, the various types of operators and appurtenances as required. Before setting these items, the MFEM shall check all Drawings and figures which have a direct bearing on their location. The MFEM shall be responsible for the proper location of valves and appurtenances during the fabrication of all MFEM supplied items on which valves are installed. All materials shall be carefully inspected for defects in construction and materials. All debris and foreign material shall be cleaned out of openings, etc. All valve flange covers shall remain in place until connected piping is in place. All operating mechanisms shall be operated to check their proper functioning and all nuts and bolts checked for tightness. Valves and other equipment which do not operate easily, or are otherwise defective, shall be repaired or replaced at no additional cost to the District. Unless otherwise noted, joints for valves and appurtenances shall be made up utilizing the same procedures as specified under the applicable type connecting pipe joint and all valves and other items shall be installed in the proper position as recommended by the manufacturer. The MFEM shall be responsible for verifying manufacturers' torque requirements for all valves. In horizontal pipe runs centered less that 4'4" above the operating floor, orient valve stems as close to vertical as permitted by adjacent piping. IS1W.Vslwr and A~W~ncer.doc 1 s 1'00-32 APRIL 27,2001 city of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT F. G. H. 3.02 A. B. C. D. E. 3.03 A. 3.04 A. 3.05 A. In horizontal pipe runs centered between 4’6” and 6’4’’ above the operation floor, orient the valve stems as close to horizontal as permitted by adjacent piping. In vertical pipe runs, orient the valve stems in the most accessible position for operation from the operating floor. The Installation Contractor will install all loose shipped valves provided by the MFEM. COMMISSIONING See also Division 1. Take care not to over pressure valves or appurtenances during pipe testing. If any unit proves to be defective, it shall be replaced or repaired to the satisfaction of the Engineer. No testing shall be performed until the manufacturer’s service engineer has provided written certification that the installed equipment has been examined and found to be in complete accordance with the manufacturer’s requirements. Functional Test: Prior to plant startup, all items shall be inspected for proper alignment, quiet operation, proper connection and satisfactory performance. All units shall be operated continuously while connected to the attached piping for at least 48 hours, without vibration, jamming, leakage, or overheating and perform the specified function. The various pipe lines in which the valves and appurtenances are to be installed are specified to be field tested. During these tests any defective valve or appurtenance shall be adjusted, removed and replaced, or otherwise made acceptable to the Engineer. Various regulating valves, strainers, or other appurtenances shall be tested to demonstrate their conformance with the specified operational capabilities and any deficiencies shall be corrected or the device replaced or otherwise made acceptable to the Engineer. OPERATOR TRAINING The MFEM shall provide training of the District’s operations and maintenance personnel for the valves and appurtenances supplied as specified in Section 01 73 1. ACCEPTANCE TESTING Acceptance testing of valves and related appurtenances will be conducted as part of the overall system acceptance testing as specified in Section 01670. MANUFACTURER’S ASSISTANCE Field Services APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT 1. A factory trained field representative of valve and component manufacturers shall be present at the jobsite or other accepted location to certify proper installation and provide instruction to the District’s personnel. The representative may be a factory trained employee of the MFEM. ++ END OF SECTION ++ 15 100-34 APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility m EQUIPMENT PROCUREMENT SECTION 161 00 ELECTRICAL WORK PART 1 - GENERAL 1.01 DESCRIPTION A. Description of Work 1. MFEM shall provide all materials, equipment, and incidentals as specified, and required to furnish, calibrate, and place in operation the electrical work provided by the MFEM as part of any factory assembled equipment as required by the Procurement Documents. 2. These specifications identify the major elements of the electrical system. They are intended to clarify the principal features. 3. Grounding: Ground all equipment in conformance with the National Electrical Code. 1.02 QUALITY ASSURANCE A. Requirements of Regulatory Agencies: 1. Material and equipment shall be installed in accordance with the current standards and recommendations of the National Electrical Code, the National Electrical Safety Code and with local codes that apply. Where discrepancies arise between codes, the most restrictive regulation shall apply. 2. Tests by Independent Regulatory Agencies: Electrical material and equipment shall be new and shall bear the label of the Underwriters' Laboratories, Inc., or other nationally recognized, independent testing laboratory, wherever standards have been established and label service regularly applies. 3. Acceptable Manufacturers: a. Furnish equipment by the named manufacturers, or if stated as or equal equipment by other manufacturers. b. The named manufacturers have been specified to establish the standard of quality and performance of the equipment to be supplied. c. Obtain all equipment of a given type from the same manufacturer, 161W.ELECTRICAL WORK.wC 16100-1 APRIL 27.2001 City of Carlsbad MF EQUIPMENT PROCUREMENT Carlsbad Recycling Facility 4. Manufacturers' Responsibilities and Services: a. Design and manufacture the equipment in accordance with the applicable general design requirements and the detailed specifications herein. B. Reference Standards: Electrical material and equipment shall conform in all respects to the latest approved standards of the following: 1. 2. 3. 4. 5. 6. 7. 8. 9. National Electrical Manufacturers Association (NEMA). The American National Standards Institute (ANSI). The Institute of Electrical and Electronic Engineers (IEEE). Insulated Cable Engineers Association (ICEA). National Electrical Code (NEC). National Electrical Safety Code (NESC). National Fire Protection Association (NFPA). Instrumentation Society of America (ISA). Undenvriters"Laboratories, Inc. OJL) 1.03 SUBMITTALS A. Shop Drawings: Submit for approval the following: 1. Manufacturer's name and product designation or catalog number. 2. Electrical ratings. 3. Dimensioned plan, section, and elevations showing means for mounting, conduit connection, and grounding. 4. Materials and finish specification, including paints. 5. List of components including manufacturer's names and catalog numbers. 6. Internal wiring diagrams indicating all connections to components and numbered terminals for external connections, in accordance with ANSVNFPA 79 - Electronic Equipment. 7. Submit complete manuals in accordance with Section 01730, Operation and Maintenance Manuals, which include the following as a minimum: 161W.ELECTRICAL WORK.Doc 16100-2 APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT a. Copies of all approved Shop Drawings, test reports, maintenance data and schedules, and spare parts information. b. As-built wiring diagrams. 1.04 PRODUCT DELIVERY, STORAGE, AND HANDLING: 1. Delivery of products to site is prohibited until all product information and Shop Drawings have been approved. PART 2 - PRODUCTS 2.01 PROCESS SYSTEM DESIGN AND PERFORMANCE A. Service Conditions 1. Area Classification a. The work provided under this contract shall be considered to be in a Wet location. 2. The electrical and control systems shall be designed and constructed for continuous operation under the following temperature and humidity conditions: a. Indoor locations for equipment, control panels, and instruments. 1) Ambient Temperature: 20°F to 105°F. 2) Relative Humidity: 98 percent maximum 2.02 EQUIPMENT DESIGN AND FABRICATION A. General 1. Materials, equipment and incidentals in wet locations shall meet NEC and NEMA 4X requirements for wet locations. Enclosures shall be NEMA 4X 316 SS unless specified otherwise. Conduits shall be terminated at enclosures with watertight, threaded hubs. 2.03 EQUIPMENT AND COMPONENTS A. Raceway Systems 1. General: The types of raceways required include the following: a. PVC coated rigid steel for exposed conduit runs in Wet locations. 16IW.ELEClTUCAL WORK.wC 16100-3 APRIL 27,2001 City of Carlsbad MF EQUIPMENT PROCUREMENT Carlsbad Recycling Facility b. Flexible PVC coated steel core liquid tight conduit for exposed conduit runs less than 36-inches in Wet locations. c. Cable tray for 24 VACNDC circuit wiring within the membrane unit skid framework. B. PVC Coated Rigid Steel Conduit, Elbows, Fittings, Couplings, and Outlet Bodies: 1. Material: Rigid, heavy wall, mild steel, hot dip galvanized, smooth interior, tapered threads, carefully reamed ends, 3/4-inch NF'S minimum size with an interior factory coating of 2 mil thick polyvinyl chloride and exterior factory coating of 40 mil thick polyvinyl chloride. Fittings and Bodies to be gasketed and watertight. Gaskets to be of an approved type designed for the purpose. Improvised gaskets not acceptable. All units to be threaded type with five full threads. Material to conform to ANSI C80.4 and be listed by UL. The use of "LB" fittings shall be avoided and type "LBD" fittings applied wherever the use of fittings is unavoidable. 2. Color: Color of coating shall be the same on all conduit and fittings. 3. Manufacturer: Provide PVC coated rigid steel conduit and fittings of one of the following: a. Robroy Industries; b. Oca1 Blue; c. Or equal. C. Conduit Hubs 1. Material: Threaded conduit hub, vibration proof, weather proof with captive 0- ring seal, zinc metal with insulated throat. Hubs used on PVC coated conduit systems shall have a factory applied PVC coating. 2. Use: Provide for all conduit terminations to boxes, cabinets and other enclosures located in areas designated as wet locations. 3. Manufacturer: Provide material manufactured by Myers Electrical Products Company or equal. D. Flexible Conduit 161W.ELECrnCAL woRK.Doc 1 6 1 00-4 AF'RIL 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT 1. Material: Flexible galvanized steel core with smooth, abrasion resistant, liquid- tight, polyvinyl chloride cover. Continuous copper ground built in for sizes 3/4- inch through 1-1/4 inch. Material shall be UL listed. 2. Product and Manufacturer: Provide one of the following: a. Sealtite UA, as manufactured by Anaconda Metal Hose Division, Anaconda American Brass Company; b. Liquatite Type L.A., as manufactured by Electric-Flex Company; c. Or equal. E. Flexible Conduit Fittings 1. Material and Construction: Malleable iron with cadmium finish. Fittings shall adapt the conduit to standard threaded connections, shall have an inside diameter not less than that of the corresponding standard conduit size and shall be UL listed. 2. Manufacturer: Provide flexible conduit fittings of one of the following: a. Crouse Hinds Company; b. Appleton Electric Company; c. Or equal. F. Cable Tray 1. Type: Galvanized steel cable tray with wiring secured by commercial nylon ties. 2. Applicable Standards: Comply with NEMA VE 1 - Metal Cable Tray Systems and VE 2 - Metal Cable Tray Installation Guidelines. 3. Steel Tray: a. Construction: Fabricated of two side rails and bottom. b. Duty: Medium. c. Steel Sheet: ASTM A569 - Standard Specification for Steel, Carbon (0.15 Maximum, Percent), Hot-Rolled Sheet and Strip Commercial Quality. d. Bottom: Sheet perforated for ventilation, minimum 60 percent solid plane for support. 161W.ELECTRICAL WORKDOC 16 100-5 APRIL 27,2001 City of Carlsbad ?viF EQUIPMENT PROCUREMENT Carlsbad Recycling Facility e. Finish: Hot dip galvanized after fabrication; ASTM A123 - Standard Specification for Zinc (Hot-Galvanized) Coatings on Products Fabricated From Rolled, Pressed, and Forged Steel Shapes, Plates, Bars and Strips. 4. Fittings: Manufacturer's standard splice plates, elbows, risers, tees, crosses, Y, reducer plates, blind ends, barrier strips, radiused drop-outs, divider strips.with resilient PVC cap strip; ventilated. Each item plated or coated same as cable tray. 5. Cable Accessories: Manufacturer's standard [cable clamps and supports, cable ties, conduit clamps and brackets. 6. Attachment Accessories: Manufacturer's standard bolt and nut fasteners, clamps, J-bolts, hangers, and connectors. Each item electro-zinc plated or coated same as cable tray. 7. Manufacturer: Provide cable tray system of one of the following: a. GS Metals Corp., Globetray; b. West-Coast Engineering Works Pvt. Ltd.; c. Or equal. G. Wire and Cable 1. 600 Volt Cable: a. Insulated Cable In Raceways: Material: Single conductor copper cable conforming to ASTM B3 - Standard Specification for Soft or Annealed Copper Wire and B8 - Standard Specification for Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft, with flame-retardant, moisture and heat resistant cross-linked polyethylene or thermoplastic insulation rated 90 "C in dry locations and 75 "C in wet locations and listed by UL as Type XHHW or THHN/THWN. Application: Use XHHW for #4 and larger and THHN/THWN or XHHW for #6 and smaller. Wire Sizes: Not smaller than No. 12 AWG for power and lighting and No. 14 AWG for 120 volt control circuits. Stranding: All 600 volt cable shall be stranded except that solid cable, size 10 and smaller may be used for lighting and receptacle circuits. I61W.ELECTRICAL WORKDOC 161 00-6 APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT 5) Manufacturer: Provide cable of one of the following: a) Okonite; b) General; c) Or equal. 2. Cable Connectors, Solderless Type: a. For wire sizes up to #6 AWG, use compression type. b. For sizes #4 AWG and above, use either compression type or bolted type with silver-plated contact faces. c. Properly size connectors to fit fastening device and wire size, 3. Instrumentation Cable: a. Single Shielded Pair: 1) Tinned copper, stranded conductors, #16 AWG minimum, twisted with aluminum-polyester shield, stranded tinned 20 AWG copper drain wire and overall chrome vinyl jacket. Rated for 600 volts minimum. b. Multiple Shielded Triads: 1) Tinned copper, stranded conductors, #16 AWG minimum, twisted with individual aluminum-polyester shield, stranded tinned 20 AWG copper drain wire and overall shielding with chrome vinyl jacket. Rated for 600 volts minimum. 2) Manufacturer: Provide shielded cable of one of the following: a) Okonite Company; b) Belden Company; c) Or equal. H. Wiring Devices 1. Snap Switches: a. Switches for Non-Hazardous Locations: I61W.ELECTRICAL WOIKDOC 16 100-7 APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT Single pole AC toggle switch, quiet type, 120/277 volt AC, 20 ampere, Ivory, specification grade. a) Product and Manufacturer: Provide one of the following: (1) Cat. #1221-I, as manufactured by Harvey Hubbel (2) Cat. #1991-I, as manufactured by Arrow-Hart (3) Or equal. Incorporated; Incorporated; Single pole, 3-way AC toggle switch, quiet type, 120/277 volt AC, 20 ampere, Ivory, specification grade. a) Product and Manufacturer: Provide one of the following: (1) Cat. #1223-I, as manufactured by Harvey Hubbell (2) Cat. #1993-I, as manufactured by Arrow-Hart (3) Or equal. Incorporated; Incorporated; 2. Receptacles: a. Duplex grounding receptacle, two pole, three wire, 125 volt AC, 20 ampere. 1) Product and Manufacturer: Provide one of the following: a) Cat. #53CM62, as manufactured by Harvey Hubbell Incorporated; b) Cat. #5362-CR, as manufactured by Arrow-Hart Incorporated; c) Or equal. 3. Disconnect Switches: a. Safety Disconnect Switches: 1) Type: Fused or unfused as required, heavy-duty, single throw, quick- make, quick-break mechanism, visible blades in OFF position and safety handle. If fused type is required, furnish fuses as recommended by manufacturer of equipment being served. 2) Rating: Voltage, number of poles and short circuit rating as shown on the Drawings. Switch shall bear a UL label and shall be suitable 16IW.ELUTTrUCAL WORK.Doc 161 00-8 APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT for use as service entrance equipment, with solid neutral assembly and equipment ground kit. 3) Manufacturer: Provide disconnect switches of one of the following: a) Cutler Hammer; b) SquareD; c) Or equal. I. Grounding Systems 1. Bare Ground Cable: a. Material: Annealed, bare, stranded copper, No. 8 AWG minimum size. b. Manufacturer: Provide ground cable of one of the following: 1) Cablec Corporation; 2) General Cable Corporation; 3) Rome Cable Company; 4) Or equal. 2. Grounding Connectors: a. Material: Pressure connectors to be copper alloy castings, designed specifically for the items to be connected, and assembled with Durium or silicone bronze bolts, nuts, and washers. Welded connections to be by exothermic process utilizing molds, cartridges, and hardware designed specifically for the connection to be made. b. Manufacturer: Provide grounding connectors of one of the following: 1) Pressure Connectors: a) O.Z./Gedney, Division of General Signal Corporation; b) Burndy Corporation; c) Or equal. 2) Welded Connections: I61W.ELECTRICAL W0RK.DOC 16 100-9 APRIL. 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT a) Cadweld by Eric0 Products, Incorporated; b) Therm-0-Weld by Bumdy Corporation; c) Or equal. J. Control Equipment 1. Manual Motor Starters: a. Type: Lockable, toggle operated, horsepower rated with thermal overload protection. b. Nameplate identifying the equipment controlled. c. Product and Manufacturer: Provide one of the following: 1) Type MS, as manufactured by Westinghouse Electric Corporation; 2) Type CR101, as manufactured by General Electric Company; 3) Type 609T, as manufactured by Allen Bradley Company; 4) Or equal. 2. Control Stations: a. b. C. d. e. f. g. Type: Industrial, heavy duty, oiltight, round, 30.5 mm, NEMA 4X non- corrosive non-metallic construction with clearly marked legend plates. Lockout Stop: Maintained contact type with provisions for locking. Pushbuttons: Momentary or maintained types, NEMA A600 contact rating. Selector Switches: Rotary type with round or oval handles and positioning device to securely hold switch in selected position. Indicating Lights: Push-to-test, transformer type with LED cluster type lamps. Lens color green for running, red for stopped or ready and amber for failure. Nameplates identifying equipment controlled. Manufacturer: Provide control stations of one of the following: 1) Cutler-Hammer; I61W.ELECTRICAL WORK.LKJC 16100-10 APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT 2) Allen Bradley; 3) Or equal. 3. Combination Magnetic Motor Starters: a. Type: Individual enclosed type with the following features: Magnetic type circuit breaker (65 KAIC), 480 VAC, 3-phase, 60 Hz, with through the door lockable handle. NEMA rated starter, size 1 minimum. Solid state electronic overload protection. Fused 480-120VAC control power transformer. Heavy duty operator devices, in accordance with this Specification Section. Enclosure type suitable for location as defined in this Specification Section. Nameplate identifying the equipment controlled. Product and Manufacturer: Provide one of the following: a) Cutler HammerlWestinghouse; b) Or equal. PART 3 - EXECUTION 3.01 DELIVERY AND INSTALLATION A. General 1. Mount equipment so that sufficient access and working space is provided for safe operation and maintenance. 2. Securely fasten enclosures to surfaces on which they are mounted. Provide independent supports where no walls or other structural surface exists. 3. Install in conformance with the National Electrical Code and all local codes. 4. Transmitters and instruments which require periodic calibration shall be readily accessible. 161W.ELECTRICAL WOK.DOc 16100-11 APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility h4F EQUIPMENT PROCUREMENT B. Raceway Systems 1. supports: a. Rigidly support conduits by clamps, hangers or unistrut channels. b. Support single conduits by means of one-hole pipe clamps in combination with one-screw back plates, to raise conduits from the support surface. Support multiple runs of conduits on trapeze type hangers with steel horizontal members and threaded hanger rods, Kindorff or equal. Rods shall be not less than 3/8-inch diameter, and shall be cadmium coated. 2. Fastenings: Fasten raceway systems rigidly and neatly to supporting structures. 3. Exposed Conduit: a. Install parallel or pelpendicular to structural members. b. Wherever possible, run in groups. Provide galvanized conduit racks of suitable width, length and height and arranged to suit field conditions. Support every ten feet minimum. c. Install on structural members in protected locations. d. Locate clear of interferences. e. Install vertical runs plumb. Unsecured drop length not to exceed 12 feet. 4. Field Bends: No indentations. Diameter of conduit shall not vary more than 15 percent at any bend. 5. Joints: a. Apply conductive compound to all joints before assembly. b. Make up joints tight and ground thoroughly. c. Use standard tapered pipe threads for conduit and fittings. d. Cut conduit ends square and ream to prevent damage to wire and cable. e. Use full threaded couplings. Split couplings not permitted. f. Use strap wrenches and vises to install conduit. Replace conduit with wrench marks. I61W.ELECTIUCAL WORK.DoC 16100-12 APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility m EQUPMENT PROCUREMENT g. Apply zinc-rich paint to exposed threads and other areas of galvanized conduit system where the base metal is exposed. 6. Terminations: a. Install insulated bushings on conduits entering boxes or cabinets, except threaded hub types. b. Provide locknuts on both inside and outside of enclosure for grounding. c. Bushings not to be used in lieu of locknuts. 7. Moisture Protection: a. Plug or cap conduit ends at time of installation to prevent entrance of moisture or foreign materials. b. Avoid pockets or depressions in conduit runs. 8. Corrosion Protection: a. Dissimilar Metals: 1) Take every action to prevent the occurrence of electrolytic action between dissimilar metals. 2) Do not use copper products in connection with aluminum work, and do not use aluminum in locations subject to drainage of copper compounds on the bare aluminum. 3) Back paint aluminum in contact with masonry or concrete with two coats of aluminum-pigmented bituminous paint. b. PVC Coating: Field apply a 40 mil thick polyvinyl chloride coating to supports and fasteners for PVC coated conduit runs. 9. Flexible Conduit: a. Install at motors and equipment which are subject to vibration or require movement for maintenance purposes. Provide necessary reducer where equipment hmished cannot accept 3/4-inch size flexible conduit. Limit flexible conduit length to three feet maximum. 10. Pull and Junction Boxes: 16100-13 APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT a. Install pull boxes in runs containing more than three 90 degree bends, and where required to conform with the National Electrical Code. b. Size junction and pull boxes in accordance with the requirements of the National Electrical Code. c. Provide terminal blocks in junction boxes where cable terminations or splices are required. 1 1. Wire and Cables: a. 600 Volt Cable: 1) Install all cables complete with proper terminations at both ends. Check and comect for proper phase sequence and proper motor rotation. b. Pulling: 1) Use insulating types of pulling compounds containing no mineral oil. 2) Pulling tension shall be within the limits recommended by the wire and cable manufacturer. 3) Use a dynamometer where mechanical means are used. 4) Cut off section subject to mechanical means. 5) Bending Radius: Limit to 6 times cable overall diameter. 6) Slack Provide maximum slack at all terminal points. c. Splices: 1) Where possible, install cable continuous, without splice, from termination to termination. 2) Where required, splice in junction box using terminal boards. 3) Splices in conduits not allowed. d. Identification: Identify all conductors by circuit number and phase at each terminal or splice location. 'e. Identify and provide color coded power and control cables in accordance with the NEC, and ICEA standards. 16100.ELECTRICAL W0RK.DoC 16100-14 APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT 12. Instrumentation Cable: a. Install in conduit separate &om power cables unless otherwise noted. b. Ground shield on shielded cables at one end only. c. Terminate stranded conductors with pre-insulated crimp type spade or ring torque terminals properly sized to fit fastening device and wire size. d. Install and terminate vendor furnished cable in accordance with vendor equipment requirements. 13. Wiring Devices: a. Outlet Boxes: 1) Fasten boxes rigidly and neatly to supporting structures. 2) For units mounted on masonry or concrete walls, provide suitable 1/2-inch spacers to prevent mounting back of box directly against wall. 3) Leave no open conduit holes in boxes. Close unused openings with capped bushings. 4) Label each circuit in boxes and identify with durable tag. 14. Snap Switches: a. Install switches in outlet or device boxes in non-hazardous locations. b. Mount wall switches 4 feet 6 inches above finished floor unless otherwise noted. 15. Receptacles: a. Install receptacles in outlet or device boxes. b. Install receptacles with ground pole in the down position. 16. Grounding Systems: a. Equipment Grounding: b. Ground all electrical equipment in compliance with the National Electrical Code. 161W.ELECTRICAL WORKDOC 16100-15 APRIL 27,2001 City of Carlsbad MF EQUIPMENT PROCUREMENT Carlsbad Recycling Facility C. d. e. f. g. h. Equipment grounding conductors shall be stranded copper cable of adequate size installed in conduit where necessary for mechanical protection. Ground conductors, pulled into conduits with non-grounded conductors, shall be insulated. Color of insulation shall be green. Connect ground conductors to conduit with copper clamps, straps or with grounding bushings. Connect to piping by welding or brazing. Use copper bonding jumpers on all gasketed joints. Connect to equipment by means of lug compressed on cable end. Bolt lug to equipment frame using holes or terminals provided on equipment specifically for grounding. Do not use holddown bolts. Where grounding provisions are not included, drill suitable holes in locations designated by Owner Connect to motors by bolting directly to motor frames, not to sole plates or supporting structures. Scrape bolted surfaces clean and coat with a conductive oxide-resistant compound. 3.02 COMISSIONING A. Inspections: Accompany the normal installation tests with inspections to demonstrate to the satisfaction of the District the following: 1. Connections: All circuits are properly connected in accordance with the Drawings and applicable approved Shop Drawings. 2. Operation: All circuits and devices are operable. 3. Identification: All conductors are properly identified at each terminal. B. Testing: 1. 600 Volt Cable: a. Test each electrical circuit after permanent cables are in place to demonstrate that the circuit and connected equipment perform satisfactorily and that they are free from improper grounds and short circuits. b. Individually test 600 volt cables for insulation resistance between phases and from each phase to ground. Test after cables are installed and before they are put in service with a Megger whose rating is suitable for the tested 16I(IO.ELECTRICAL WORK.DOC 16100-16 APRIL 27,2001 City of Carlsbad MF EQUIPMENT PROCUREMENT Carlsbad Recycling Facility circuit. Tests shall meet with the applicable specifications of NEMA WC-7 - Cross-Linked-Thermosetting-Polyethylene-Insulated Wire and Cable for the Transmission and Distribution of Electrical Energy. c. The insulation resistance for any given conductor shall not be less than 1 megohm for 600 volt and less service. Any cable not meeting this value or which fails when tested under full load conditions shall be replaced with a new cable for the full length. 2. Instrumentation Cable: a. Test shielded instrumentation cable shields with an ohmmeter for continuity along the full length of the cable and for shield continuity to ground. b. Connect shielded instrumentation cables to a calibrated 4-20 milliamp DC signal transmitter and receiver. Test at 4, 12, and 20 milliamp transmitter settings. 3. Grounding System: a. Test the completed ground systems for continuity and for resistance to ground using an electrical ground resistance tester. 3.03 OPERATOR TRAINING A. General 1. Provide training on components of the system electrical facilities in accordance with Section 01 73 1. 3.04 ACCEPTANCE TESTING A. General 1. Provide testing services in accordance with Section 01670. B. Operation Tests 1. Operate all starters, circuit breakers and associated equipment to demonstrate suitability and compliance with Specifications and reference standards, except for short circuit interrupting rating or other inherent design features covered by shop tests. 2. Test all motors for direction of rotation and reverse connections if necessary. 161W.ELECTRICAL WOFXDOC 16100-17 APRIL 27,2001 City OfCarlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT 3. Check control circuits to determine that operation and sequence are correct and adjust limit switches, pressure switches, float switches, timers and other devices to give proper operation. 3.05 MANUFACTURERS ASSISTANCE A. Field Services 1. A factory trained field representative of component manufacturers shall be present at the jobsite or other accepted location to certify proper installation and provide instruction to the District’s personnel. The representative may be a factory trained employee of the MFEM. + + END OF SECTION + + 161W.ELECTRICALWORK.DOC 16100-18 APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT SECTION 16484 LOW VOLTAGE VARIABLE FREQUENCY DRIVES (6 PULSE) PART 1 - GENERAL 1.01 DESCRIPTION A. Scope: The h4FEM shall furnish all labor, materials, equipment, services, and incidentals required to provide variable frequency drives (VFDs) integrated with semiconductors for a 6 pulse arrangement with phase shifting transformer, complete and operational with controls and accessories as shown and specified. B. Coordination 1, All VFDs shall be furnished under Division 16, shall be of the same manufacturer and shall be furnished by a single supplier under Division 16. 2. The MFEM shall have sole and total responsibility for the satisfactory installation and operation of each entire system including driven equipment, motors, VFDs, and controls as specified by the Procurement Documents. 3. The MFEM shall submit an acceptance letter from both the driven equipment and motor manufacturers stating that the VFD will fully meet all starting and operating requirements of each driven equipment/motor combination. 4. The MFEM shall submit a letter from the VFD manufacturer stating that they have reviewed the driven equipment requirements and that the VFD will successfully meet all operating requirements in each instance. 1.02 QUALITY ASSURANCE A. Reference Standards: Comply with applicable provisions and recommendations of the following, except as otherwise shown or specified. 1. National Electric Code. 2. Standards of National Electrical Manufacturers Association. 3. Institute of Electrical and Electronic Engineers. 4. BEE 519,1992. B. Manufacturer's Qualifications: Manufacturer of the equipment specified herein shall have experience in providing similar type equipment and shall show evidence with his 16484.MW VOLTAGEVFDS (6PULSE).WC 16484-1 APRn 21,2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT submittal of at least five (5) installations where equipment of the same material and same application of the type specified herein have been in satisfactory operation for at least five (5) years. The list of installations shall include the name and telephone number of the Plant Superintendent at each of the five (5) qualifying installations. C. The manufacturer shall demonstrate in writing the quality assurance program in use to certify key components. In-house manufacture of key components is desirable, and will be considered in judging acceptance. 1.03 SUBMITTALS A. Shop Drawings: Submit for approval in accordance with the procedures specified in Section 01340, the following: 1. 2. 3. 4. 5. 6. 7. 8. 9. Manufacturer's literature, illustrations, specifications, and engineering data which indicate: performance, dimensions, materials, size, and weight. Fabrication, assembly, and installation drawings, and wiring diagrams. Schematic and wiring diagrams shall comply with ANSI/NFPA 79 - Electronic Equipment. Complete list of components and catalogue identification. List of in-house manufactured key components. Quality assurance program description. Complete schematic and wiring diagrams and description of functional operation. Complete calculations for estimated total hannonic current and voltage distortion, including peak transients at each motor terminals, based on the following data: a. Available fault current of 60,00OA, 480VAC, at the incoming terminals of the VFD. b. Feeder cable sizes and lengths (assume 120 feet of cable as sized per the NEC). Recommended spare parts list. Coordination compliance letters. B. Factory Test Reports 1. Each variable frequency drive shall be tested at the manufacturer's facility. 16484.LOW VOLTAGE VFDS (6 PULSE).DOC ~~~ 16484-2 APRIL 27,2001 City of carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT 2. The testing procedure shall be the manufacturer's standard procedure to assure maintenance free service. The Owner shall be given seven (7) days notice prior to start of factory testing so that the Owner, at his option, may witness the testing. a. All final assemblies shall be tested at full load with application of line-to- line bolted fault. The VFD shall trip electronically without device failure. b. After all tests have been performed, each VFD shall undergo a 40 hour burn-in test. The VFDs shall be burned in at 100 percent inductive or motor load for 40 hours without an unscheduled shutdown. c. After the bum-in cycle is complete, each VFD shall be put through a 30 minute cycling motor load test before inspection and shipping. d. Certification that all of the testing above has been performed shall be provided by the VFD manufacturer. 3. In addition to the manufacturer's standard tests, each VFD, including all instruments, selector controls, solid state components, systems, and internal and external equipment which are a part of the VFDs shall be assembled, tested, and thoroughly checked for proper operation of all functions and features. Dummy signals and loads shall be employed that will simulate actual signals and loads if they are a part of the final installation and are not included in this Section. 4. All equipment, devices, instrumentation, and personnel required to perform the tests shall be supplied by the manufacturer. Upon satisfactory completion of the test, the manufacturer shall submit four (4) certified copies of the test report to the District. Component failure during testing will require repeating any test associated with the failure or modified components to demonstrate proper operation. 5. If the test results indicate that any VFD unit does not conform to specified and/or guaranteed performance, the unit shall be modified and retested, at no additional cost to the District, until full compliance with specified and guaranteed performance can be demonstrated. The DistrictEngineer shall be permitted to witness the retest and shall be given 7 days notice of intent of the manufacturer to retest. 6. No equipment shall be shipped until the District has approved all test reports. C. Installation Instructions 1. The VFD manufacturer shall provide written instructions for proper drive and accessory component installation. 2. VFDs not integral to unit skid assemblies furnished by the MFEM will be installed by the Installation Contractor. 16484.WW VOLTAGE VFDS(6PULSE).WC 16484-3 APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT D. Operation and Maintenance Manuals: Submit complete manuals including: 1. Copies of all approved Shop Drawings with as-built wiring diagrams, test reports, maintenance data and schedules description of operation, and spare parts information. 2. Furnish operation and maintenance data in conformance with the requirements of Section 01730, Operation and Maintenance Manuals. 1.04 PRODUCT DELIVERY, STORAGE, AND HANDLING A. Deliver equipment to the site to ensure unintmpted progress of the Work. B. Unload, store, and handle equipment in accordance with manufacturer's recommendations and requirements of the Procurement Documents. C. Arrange storage in a manner to provide easy access for inspection. D. Store all equipment in covered storage off the ground. E. Store all electrical and electronic equipment, control panels, and like equipment and materials in heated buildings which have a concrete or wooden floor, a roof, and fully closed walls on all sides. Protect electrical and electronic equipment from contamination by dust, dirt, and moisture. Energize space heaters to temporary power during storage and construction. Maintain humidity at levels recommended by manufacturer for electric and electronic equipment. PART 2 - PRODUCTS 2.01 PROCESS SYSTEM DESIGN AND PERFORMANCE A. The MFEM shall furnish constant torque variable frequency drive units, AC pulse width modulated (PWM) inverter type, 460 volts, sine coded with carrier frequency adjustment, multi-converter 6 pulse arrangement with phase shifting transformer for harmonics attenuation, 3-phase, 60 Hertz input with output suitable for and coordinated with the driven equipment furnished. Controls shall be furnished as specified herein and as shown on the Procurement Drawings. B. Prototypes or newly introduced drive unit models are not acceptable. C. The drive shall be capable of operating under any combination of the following conditions without mechanical or electrical damage. 1. Ambient temperature 0 to 40 "C. 2. Relative humidity 0 to 95 percent non-condensing. IM84.LOW VOLTAGE VFDS (6 PULSE).WC 16484-4 APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMENT 3. Altitude of 100 feet above sea level. 4. Vibration 0 to 0.5G. 2.02 EQUIPMENT DESIGN AND FABRICATION A. Enclosures 1. For indoor locations, the VFDs shall be housed in NEMA 1, filtered, free- standing, floor-mounted cabinets. Conduit and cable entrances shall be from the top. 2. For outdoor locations, the VFDs shall be housed in NEMA 3R (minimum) enclosures, filtered, ventilated, free-standing, floor mounted cabinets. Conduit and cable entrances shall be from the bottom. 3. All VFD control panels shall be listed in accordance with UL 508 - Control Equipment. B. Drive System Requirements 1. Drive input will be 480-volt, three-phase, 60-Hz supply that is within f10 percent of nominal line voltage. Drive shall convert the input power to an adjustable frequency and voltage output. Output frequency and voltage of the dnve shall be adjustable to maintain a constant VMz ratio throughout the operating range. 2. The rectifier stage shall convert fixed-voltage, fixed-frequency, AC line power to fixed-DC voltage. The input power section shall utilize an input line reactor and a full wave bridge design incorporating diode rectifiers. Designs that incorporate silicon controlled rectifiers (SCRs) will not be allowed. 3. DC bus voltage shall be filtered. 4. Rectifier shall be insensitive to the phase rotation of the AC line and shall not cause a displacement power factor of less than 0.95 lagging under any speed or load condition. 5. The inverter shall change fixed DC voltage to variable frequency, variable AC voltage. The inverter section shall utilize Gate Turn-Off Thyristor power devices or transistors as required by the current rating of the motor. The drive shall be capable of operating into an open circuit without damage in order to facilitate startup/maintenance. 6. The drive efficiency shall be 98 percent at full speed, full load; exclusive of auxiliary loads. Drive efficiency shall be 95 percent at full speed, full load, inclusive of auxiliary loads. 16484.LOW VOLTAGE VFDS (6 PULSE).WC 16484-5 APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMEN? 7. The acceleration and deceleration ramp rates shall be adjustable from 1 to 60 seconds. 8. The overload trip shall be adjustable from 0 to 100 percent of rated output current. 9. The current limit shall be adjustable from 60 to 120 percent of rated output current to maximize starting torque on a variable torque load. 10. The voltage boost shall be adjustable from 100 to 400 percent of nominal V/Hz ratio at 1 Hz tapering to 100 percent at 20 Hz. 11. A nonadjustable instantaneous overcurrent trip shall be set to 250 percent of rated output current. 12. Protection of the drive shall be accomplished without the use of fast acting semiconductor output fuses. Subjecting the controller to any of the following conditions shall activate fuseless electronic protective circuits and eliminate component failure or the need for fuse replacement: a. Short circuit at AC drive output. b. Ground fault at AC drive output. c. Open circuit at AC drive output. d. Input undervoltage. e. DC bus overvoltage. f. Loss of input phase. g. AC line switching transients. h. Instantaneous overload. i. Sustained overload exceeding 100 percent of controller rated current. j. Overtemperature. C. Manufacturers 1. Allen Bradley; 2. ABB; 3. Cutler Hammer; 4. Robicon. 1~84.~0~ VOLTAGE vms (6 PULSE).^ 16484-6 APRIL 27,2001 city of Carlsbad rn EQUIPMENT PROCUREMENT Carlsbad Recycling Facility 2.03 EQUrPMENT AND COMPONENTS -NOT USED 2.04 INSTRUMENTATION AND CONTROLS A. Control Options and Operator Interface 1. All VFDs shall have the required control and indication functions wired to the unit door: a. Power ON-OFF switch. b. Manual speed control potentiometer. c. LOCAL-OFF-REMOTE (LOR) switch. 1) The controller shall accept an input signal of 4-20 mA dc as the speed reference signal when the controller is in the REMOTE mode of operation. 2) The manual speed control potentiometer shall adjust the drive frequency when the switch is in LOCAL mode. Provide an output speed signal of 4-20 mA dc. 2. Drive shall be factory set for manual reset after the first protective circuit trip for a malfunction (overcurrent, undervoltage, overvoltage or overtemperature) or an interruption of power. When set for automatic restart, the drive shall attempt to restart after an adjustable or fixed time delay. If the drive fails again a manual restart will be required. . ’ 3. Drive shall be capable of restarting into a motor coasting in the forward direction without component failure or tripping off line. 4. The AC drive shall include external fault reset capability. All the necessary logic to accept an external fault reset contact shall be included. 5. Front panel pilot lamps: a. Power ON light. b. Drive RUN power light. c. Drive FAIL light. 6. Meters: a. Analog or digital speed meter calibrated 0 to 100 percent of speed. IM84.LOW VOLTAGE VFDS (6 PULSQDOC 16484-7 APRIL 27.2001 City of Carlsbad MF EQUIPMENT PROCUREMENT Carlsbad Recycling Facility b. Analog or digital output volt meter calibrated 0 to 125 percent of voltage. c. Analog or digital output ammeter calibrated 0 to 150 percent of rated current. d. Elapsed time indicator monitors drive operating time from 0 to 9999 hours, nonresetable. 7. Alternate Display/Control Interface: Digital alphanumeric status and diagnostic display, showing real time: a. Output frequency. b. Output voltage. c. output current. d. Elapsed time. e. Fault conditions. 8. Drive fault conditions shall include the following: a. b. C. d. e. f. g. Bus shoot through. Instantaneous overcurrent. Ground fault. Overload. Overtemperature. Overvoltage. Drive lockout. 9. Faults shall be stored in nonvolatile memory. 10. Resetkcan push button shall be included for reviewing data and resetting the stored fault information. 11. Provision for remote emergency stop mushroom head pushbutton to open output contactor and stop drive. B. Signal Interface 1. Digital Input: lM84.WW VOLTAGE VFDS (6 PULSE).DK 16484-8 APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQUIPMENT PROCUREMEM a. Accept a remote RUN command closure input. b. Accept a remote SHUTDOWN command closure input. c. Accept a remote EMERGENCY STOP signal to shutdown the drive, open the output contactor, initiate a DRIVE FAULT condition, and provide pass through of an additional dry contact for remote use. 2. Digital Output: Furnish four discrete output dry contact closures rated S amps at 120 VAC: a. DRIVE READY. b. DRIVE RUNNING. c. DRIVE FAULT (with common fault closure for all fault conditions). d. REMOTE (drive in REMOTE mode). e. LOCAL (drive in LOCAL mode). 3. Analog Input: When LOCAL/OFF/REMOTE switch is in REMOTE, control drive speed from a remote 4 to 20 mA dc signal. Make provisions for adjustment of minimum and maximum motor speed which will result from this signal. Factory set this adjustment to comply with operating speed range designated in driven equipment specifications. Frequency resolution shall be 0.1 percent of base speed. 4. Analog Output: Furnish two 4 to 20 mA dc signals for actual frequency and actual load. 5. Relays a. Drive RUN and SHUTDOWN relays shall allow the drive to be remotely started via a 120 VAC input. b. Drive ON relay shall provide a dry contact closure for remote monitoring. c. Drive FAIL relay shall provide a dry contact closure for remote monitoring. 2.05 SPARE PARTS A. Furnish the following spare parts for each size and model of drive supplied: 1. One (1)-Main control board 2. One (1)-IGBT gating assembly 16484.LOW VOLTAGE VFDS (6 PULSE).DOC 16484-9 APRIL 27,2001 City of Carlsbad MF EQUIPMENT PROCUREMENT Carlsbad Recycling Facility 3. Three (3)-460 volt power fuses 4. Three (3)-460 volt control fuses 5. Three (3)-120 volt control fuses 6. Three (3)-120 volt power fuses 7. Three (3)-Inverter DC fuses 8. One (1)-Filter inductor 9. One (1)-Converter thyristor 10. One (1)-IGBT 11. One (1)-Bus clamp diode 12. One (1)-IGBT snubber diode 13. One (1)-Cooling fan 2.06 SHOP PAINTING A. Units shall receive manufacturer's standard finish paint system prior to shipment. B. Machined, polished, and non-ferrous surfaces shall be coated with corrosion prevention compound. PART 3 - EXECUTION 3.01 DELIVERY AND INSTALLATION A. Refer to Sections 01610 and 01611. 3.02 COMMISSIONING A. Test each assembled drive system for functional conformance, proper operation, and wiring. B. Perform tests for a minimum period of 4-hours at ambient temperature at full load with the normal power supply. C. Verify proper operation of all integrated controls, auxiliary contacts, and protective features and devices. D. Provide a certified test report for each drive. 16484.LOW VOLTAGE VTDS(6PULSE).DOC 16484-10 APRIL 27,2001 City of Carlsbad Carlsbad Recycling Facility MF EQuPMENT PROCUREMENT 3.03 OPERATOR TRAINING A. Provide training on components of the drive system in accordance with Section 01731. 3.04 ACCEPTANCE TESTING A. Acceptance testing of the drive systems will be conducted as part of the system performance tests, as specified in Section 01670. 3.05 MANUFACTURER'S ASSISTANCE A. The MFEM shall furnish the services of a qualified factory-trained representative who shall assist as.necessary in the installation of the equipment, check the installation before it is placed into operation, supervise initial operations, and instruct the plant operators in the care, operation and maintenance of the equipment. The representative may be a factory-trained employee of the MFEM. + + END OF SECTION + + 16484.LOW VOLTAGE VFDS (6 PULSE).WC 16484-11 ~ ~ ~_____~ APRIL 27,2001