Loading...
HomeMy WebLinkAbout1982-09-21; City Council; 7164; ZC/CT/CP Daon CorpCARLSBAD - AGENDILL AR* 7 /A. </ MTC3. 9/21/82 DEPT. LUP TITLE' Zone change from R-l-10,000 to RDI1 and " a 490 unit Tentative Tract Map and Condominium Permit; south side of Corte de la Vista, east of Alicante Road. ZC-262/CT 82-15/CP-212 - DAON CORP. DEPT. HD.IiU^ CITY ATT\QEzB- HITY MGR ^^-— _._ — kj. — oI O oo RECOMMENDED ACTION: Both the Planning Staff and Planning Commission recommend that this application be APPROVED and that the City Attorney be directed to prepare documents APPROVING ZC-262/CT 82-15/CP-212, per Planning Commission Resolution Nos. 2013 and 2014. ITEM EXPLANATION; This item consists of two applications: 1) A zone change from R-1-10,000 to RDM on the easterly portion of the property, and 2) A 490 unit Tentative Tract Map and Condominium Permit. The Planning Commission found the project to be consistent with the General Plan and determined that it met all design criteria and development standards of the Planned Development Ordinance. Two issues were discussed during the public hearing: 1) grading impacts and 2) visual impacts. The Commission found that these impacts were satisfactorily mitigated by the design of the project and the conditions of approval. One commissioner questioned the calculation of the project's building height. Upon further review, staff has found that the project meets the 35' height limit of the zoning ordinance. Through staff review and Planning Commission hearing, all issues on this matter have been satisfactorily resolved. ENVIRONMENTAL REVIEW The Land Use Planning Manager has determined that this project will not cause any significant environmental impacts and, therefore, has issued a Conditional Negative Declaration, dated August 9, 1982, which was approved by the Planning Commission on August 25, 1982. A copy of the environmental documents is on file in the Land Use Planning Division office. FISCAL IMPACT The applicant will provide all required public improvements to the project. Also, the applicant has agreed to pay a public facilities fee to offset the costs of providing all other public services. EXHIBITS A) PC Resolution Nos. 2013 and 2014 B) Staff Report dated August 25, 1982, with attachments 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 PLANNING COMMISSION RESOLUTION NO. 2013 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF CARLSBAD, CALIFORNIA, RECOMMENDING APPROVAL OF A 40 LOT TENTATIVE TRACT MAP AND A 490 UNIT CONDOMINIUM PERMIT ON PROPERTY GENERALLY LOCATED ON THE SOUTH SIDE OF CORTE DE LA VISTA, EAST OF ALICANTE ROAD. APPLICANT: DAON CORPORATION CASE NO.: CT 82-15/CP-212 WHEREAS, a verified application for certain property to wit; Parcel 2 of Parcel Map 11722 in the city of Carlsbad according to Document No. 81-322184 recorded on October 9, 1981. WHEREAS, said verified application constitutes a request as provided by Title 21 of the Carlsbad Municipal Code; and WHEREAS, the Planning Commission did, on the 25th day of August, 1982, hold a duly noticed public hearing as prescribed by law to consider said request; and WHEREAS, at said public hearing, upon hearing and considering all testimony and arguments, if any, of all persons desiring to be heard, said Commission considered all factors relating to the Tentative Tract Map and Condominium Permit. NOW THEREFORE, BE IT HEREBY RESOLVED by the Planning Commission as follows: A) That the above recitations are true and correct. B) That based on the evidence presented at the public hearing, the Commission recommends APPROVAL of CT 82-15/CP-212, based on the following findings and subject to the following conditions: Findings 1) The project is consistent with the city's General Plan since the proposed density of 12.5 du's/acre is within the density range of 10-20 du's/acre specified for the site as indicated on the Land Use Element of the General Plan. 2) The site is physically suitable for the type and density of the development since the site is adequate in size and shape to accommodate residential development at the density proposed. 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 3) The project is consistent with all city public facility policies and ordinances since: a) The Planning Commission has, by inclusion of an appropriate condition to this project, insured that the .final map will not be approved unless the City Council finds that sewer service is available to serve the project. In addition, the Planning Commission has added a condition that a note, shall be placed on the final map that building permits may not be issued for the project unless the City Engineer determines that sewer service is available, and building cannot occur within the project unless sewer service remains.available, the Planning Commission is satisfied that the requirements of the public facilities element of the General Plan have been met insofar as they apply to sewer service for this project. b) Park-in-lieu fees are required as a condition of approval. c) All necessary public improvements have been provided or will be required as conditions of approval. d) The applicant has agreed and is required by the inclusion of an appropriate condition to pay a public facilities fee. Performance of that contract and payment of the fee will enable this body to find that public facilities will be available concurrent with need as required by the General Plan. e) School fees will be paid to ensure the availability of school facilities. f) Assurances have been given that adequate sewer for the project will be provided by the Leucadia County Water District. 4) The proposed project is compatible with the surrounding existing and future land uses since surrounding properties are designated for residential development on the General Plan. 5) A Conditional Negative Declaration has been issued by the Land Use Planning Manager on August 9, 1982 and approved by the Planning Commission on August 25, 1982. 6) This project complies with the Planned Development Ordinance and is consistent with the Design Guidelines Manual. Conditions: 1) Approval is granted for CT 82-15/CP-212, as shown on Exhibit(s) "A" through "0", dated August 5, 1982, and Exhibit "P", dated June 25, 1982, incorporated by reference and on file in the Lan< Use Planning Office. Development shall occur substantially as shown unless otherwise noted in these conditions. PC RESO NO. 2013 -2- 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 2) This project is approved upon the express condition that the final map shall not be approved unless the City Council finds as of the time of such approval that sewer service is available to serve the subdivision. 3) This project is approved upon the express condition that building permits will not be issued for development of the subject property unless the City Engineer determines that sewer facilities are available at the time of application for such sewer permits and will continue to be available until time of occupancy. This note shall be placed on the final map. 4) This project is approved upon the express condition that the applicant shall pay a public facilities fee as required by City Council Policy No. 17, dated April 2, 1982, on file with the City Clerk and incorporated herein by reference, and according to the agreement executed by the applicant for payment of said fee a copy of that agreement dated June 21, 1982, is on file with the City Clerk and incorporated herein by reference. If said fee is not paid as promised, this application will not be consistent with the General Plan and approval for this project shall be void. 5) The applicant shall pay park-in-lieu fees to the city, prior to the approval of the final map as required by Chapter 20.44 of the Carlsbad Municipal Code. 6) Approval of this request shall not excuse compliance with all sections of the Zoning Ordinance and all other applicable city ordinances in effect at time of building permit issuance. Land Use Planning Office 7) The applicant shall prepare a reproducible mylar of the final site plan incorporating the conditions contained herein. Said site plan shall be submitted to and approved by the Land Use Planning Manager prior to the issuance of building permits. 8) The applicant shall establish a homeowner's association and corresponding covenants, conditions and restrictions. Said CC&R's shall be submitted to and approved by the Land Use Planning Office prior to final map approval. 9) The applicant shall prepare a detailed landscape and irrigation plan which shall be submitted to and approved by the Land Use Planning Manager prior to the issuance of building permits. Said landscape plan shall indicate special treatment within and between the buildings contained within the hillside units and along Corte de la Vista to screen the parking structures from this street. 10) All landscaped areas shall be maintained in a healthy and thriving condition, free from weeds, trash, and debris. PC RESO NO. 2013 -3- 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 11) A detailed plan of the private recreation areas of the trails and split level units shall be submitted to and approved by the Land Use Planning Manager prior to the recordation of the final map. 12) The garage structures for the Trails Units shall be set back a minimum of 5' from the private driveways. 13) Any signs proposed for this development shall be designed in conformance with the city's Sign Ordinance and shall require review and approval of the Land Use Planning Office prior to installation of such signs. 14) All roof appurtenances, including air conditioners, shall be architecturally integrated and shielded from view and the sound buffered from adjacent properties and streets to the satisfaction of the Land Use Planning Manager and Building and Planning Director. 15) The applicant shall submit a street name list consistent with the city's street name policy subject to the Land Use Planning Manager's approval prior to final map approval. 16) The project shall provide bus stop facilities at locations subject to the satisfaction of the North County Transit Dis- trict. Said facilities shall at a minimum include a bench, free from advertising and a pole for the bus stop sign. The bench and pole shall be designed in a manner so as to not detract from the basic architectural theme of the project and said design shall be subject to the approval of the Land Use Planning Manager and North County Transit District. 17) Approval of Tentative Tract No. CT 82-15/CP-212 is granted subject to approval of Zone Change 262. 18) Approval of this tentative tract map shall expire twenty-four months from the date of City Council approval unless a final map . is recorded. An extension may be requested by the applicant. Said extension shall be approved or denied at the discretion of the City Council. In approving an extension, the City Council may impose new conditions and may revise existing conditions. 19) Notification shall be given to the residents in the project located adjacent to the off-site grading disposal site prior to the start of hauling operations. This notice shall be given at least 30 days prior to the start of operations and shall contain the name of a contact person to contact in case of complaints or violation of off-site grading conditions. 120) All grading equipment shall be maintained in top operating condition with adequate mufflers to mitigate noise impacts. -4-PC RESO NO. 2013 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 21) The off-site grading operation shall not be conducted during Santa Ana conditions or conditions of high winds from an easterly direction from the site toward existing residences. 22) The grading operation shall not be conducted on weekends or holidays. 23) The City Engineer and/or the Land Use Planning Manager shall have the authority to shut down the off-site grading operation should the grading contractor not fulfill any of the conditions contained herein. The applicant shall have the grading contractor sign an acknowledgement of the conditions. During any time that the operation is shut down pursuant to this condition, the applicant shall do whatever erosion control mechanisms are deemed necessary by the City Engineer. Engineering Department 24) The developer shall obtain a grading permit prior to the com- mencement of any clearing or grading of the site. 25) The grading for this project is defined as "controlled grading" by Section 11.06.170(a) of the Carlsbad Municipal Code. Grading shall be performed under the observation of a civil engineer whose responsibility it shall be to coordinate site inspection and testing to insure compliance of the work with the approved grading plan, submit required reports to the City Engineer and verify compliance with Chapter 11.06 of the Carlsbad Municipal Code. 26) Upon completion of grading, the developer shall insure that an "as-graded" geologic plan shall be submitted to the City Engineer. The plan shall clearly show all the geology as exposed by the grading operation, all geologic corrective measures as actually constructed and must be based on a contour map which represents both the pre and post site grading. This plan shall be signed by both the soils engineer and the engineering geologist. The plan shall be prepared on a mylar or similar drafting film and shall become a permanent record. 27) No Grading shall occur outside the limits of the subdivision unless a letter of permission is obtained from the owners of the affected properties. 28) Additional drainage easements and drainage structures shall be provided or installed as may be required by the County Department of Sanitation and Flood Control or the City Engi- neer. 29) All land and/or easements required by this project shall be granted to the city, without cost to the city, free and clear of all liens and encumberances. -5-PC RESO NO. 2013 i 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 30) 31) 32) 33) 34) 35) 36) 37) 38) 39) 40) Except as shown on the tentative tract map (Exhibit 'A')/ direct access rights for all lots abutting Alicante Road and Corte de la Vista shall be waived on the final map. The developer shall install street lights along all public and private street frontages in conformance with City of Carlsbad Standards (La Costa Standards). The developer shall install street. trees at the equivalent of 40-foot intervals along all public street frontages in. conformance with City of Carlsbad Standards. The trees shall be of a variety selected from the approved Street Tree List. The developer shall install sidewalks along all public street frontages in conformance with City of Carlsbad Standards prior to occupancy of any buildings. The developer shall install a wheelchair ramp at the public street corner abutting the subdivision in conformance with City of Carlsbad Standards prior to occupancy of any buildings. The developer shall comply with all the rules, regulations and design requirements of the respective sewer and water agencies regarding services to the project. The design of all private streets and drainage systems shall be approved by the City Engineer prior to approval of the final map. The structural section of all private streets shall conform to City of Carlsbad Standards based on R-value tests. All private streets and drainage systems shall be inspected by the city and the standard improvement plan check and inspection fees shall be paid prior to approval of the final map. All private streets and drainage systems shall be maintained by the homeowner's association in perpetuity. This responsibility shall be clearly stated in the CC&R's. All concrete terrace drains shall be maintained by the home- owner's association (if on commonly owned property) or the individual property owner (if on an individually owned lot) in perpetuity. An appropriately worded statement clearly identifying the responsibility shall be placed in the CC&R's. The developer shall insure that there is stringent dust control at all times and that the adjacent public streets are cleaned of dirt and debris daily during all phases of the grading and construction activities. The developer shall install and maintain a temporary irrigation system on the off-site fill area until such time as the city Engineer has determined that the hydroseed landscaping has been established. PC RESO NO. 2013 -6- 41) The developer shall post a cash bond with the City to ensure the replacement and/or repair of the public street section at the locations where the off-site grading haul road crosses public streets. 42) The developer shall conduct the grading haul operations only between the hours of 7:30 AM and 4:00 PM and shall provide adequate flagman control at all times at the haul route crossings of public streets. 43) The off-site grading operation shall be accomplished in one operation. No grading shall be allowed during weekends or holidays, during Santa Anas or conditions of high winds or during the rainy season (Nov. 16 to April 15). 8 44) After the grading operations are complete all off-site grading areas and haul routes shall be restored as near as possible to the existing conditions. 10 11 12 grading permit. 13 46) Prior to the approval of the final map the developer shall 14 15 City Engineer and the Land Use Planning Manager. 16 47) Prior to the approval of the final map the developer shall 17 18 20 21 22 23 24 25 45) Prior to the start of the off-site filling operation the developer shall install a temporary desiltation basin at the low end of the drainage course adjacent to the proposed fill site. The developer shall enter into the city's standard secured maintenance agreement prior to the issuance of a submit a detailed parking layout for the City Engineer's review and approval. Should the layout be found deficient the developer shall modify the design to the satisfaction of the provide for the installation of the North half of Alga Road from Alicante Road to El Camino Real. The road shall be constructed prior to occupancy of the one hundred and first unit of the project. 19 48) Water shall be provided by the City of Carlsbad unless some other arrangement is approved by the City Council. Fire Department 49) Additional public and/or on-site fire hydrants are required. 50) Submit two (2) copies of a site plan showing locations of existing and proposed fire hydrants and on-site roads and drives. 51) An all weather access road shall be maintained throughout construction. 26 27 28 PC RESO NO. 2013 -7- 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 26 27 28 w ^ 52) All required fire hydrants, water mains and appurtenances shall be operational prior to combustible building materials being located on the project site. 53) Any proposed security gate systems shall be provided with "Knox" key operated override switch, as specified by the Fire Department. 54) All private driveways shall be kept clear of parked vehicles at all times, and shall have posted "No Parking/Fire Lane. Tow Away Zone" pursuant to Section 17.04.040, Carlsbad Municipal Code. 55) All fire alarm systems, fire hydrants, extinguishing systems, automatic sprinklers, and other systems pertinent to the project shall be submitted to the Fire Department for approval prior to construction. 56) The developer shall provide a system of addressing or building identification as approved by the Fire Chief. Parks and Recreation 57) Street trees to be planted 12 feet back from curb and species to be approved by the Parks and Recreation Department. 58) Open space area to be hydroseeded with native drought tolerant seed mix and prepared before seeding. 59) Detailed landscape and irrigation plan is required for Parks and Recreation Department approval. PASSED, APPROVED AND ADOPTED at a regular meeting of the Planning Commission of the city of Carlsbad, California, held on the 25th day of August, 1982, by the following vote, to wit: AYES: Commissioners Marcus, Friestedt, Jose NOES: Commissioners Rombotis, Rawlins ABSENT: Chairman Farrow, Commissioner Schlehuber ABSTAIN: None MARY MARCUS, Pro Tern, Chairman CARLSBAD PLANNING COMMISSION ATTEST: Secretary CARLSBAD PLANNING COMMISSION PC RESO NO. 2013 •8- 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 24 26 27 28 PLANNING COMMISSION RESOLUTION NO. 2014 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF CARLSBAD, CALIFORNIA, RECOMMENDING APPROVAL OF A ZONE CHANGE FROM R~1-10,OOQ TO RD-M ON PROPERTY GENERALLY LOCATED ON THE SOUTH SIDE OF CORTE DE LA VISTA EAST OF ALICANTE ROAD. APPLICANT: DAON CORPORATION CASE NO; ZC-262 WHEREAS, a verified application for certain property, to wit: Parcel 2 of Parcel Map 11722 in the city of Carlsbad according to Document No. 81-322184 recorded on October 9, 1981 las been filed with the city of Carlsbad, and referred to the Planning Commission; and WHEREAS, the Planning Commission did on the 25th day of August, 1982, hold a duly noticed public hearing as prescribed by law to consider said request; and WHEREAS, at said public hearing, upon hearing and considering all testimony and arguments, if any, of all persons desiring to be heard, said Commission considered all factors relating to the Zone Change; and NOW, THEREFORE, BE IT HEREBY RESOLVED by the Planning Commission as follows: A) That the foregoing recitations are true and correct. B) That based on the evidence presented at the public hearing, the Commission recommends APPROVAL of ZC-262, based on the following findings and subject to the following conditions: Findings: 1) The proposed zone change to RD-M is consistent with the General Plan designation of RMH (10-20 du's/acre). 2) Uses allowed in the RD-M zone are compatible with surrounding properties since the property to the west and east has been designated for residential purposes at a similar density and the La Costa Golf Course is located to the south. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 v ,.< 3) The applicant has agreed and is required by the inclusion of an appropriate condition to pay a public facilities fee. Per- formance of that contract and payment of the fee will enable this body to find that public facilities will be available concurrent with need as required by the General Plan. 4) The proposed change of zone is consistent with all other elements of the General Plan. 5) A Conditional Negative Declaration has been issued by the Land Use Planning Manager on August 9, 1982, and approved by the Planning Commission on August 25, 1982. Conditions 1) Approval is granted for ZC-262, as shown on Exhibit "X", dated August 25, 1982, incorporated by reference and on file in the Land Use Planning Office. 2) This project is approved upon the express condition that the applicant shall pay a public facilities fee as required by City Council Policy No. 17, dated August 2, 1982, on file with the City Clerk and incorporated herein by reference, and according to the agreement executed by the applicant for payment of said fee a copy of that agreement dated June 21, 1982, is on file with the City Clerk and incorporated herein by reference. If said fee is not paid as promised, this application will not be consistent with the General Plan and approval of this project shall be void. PASSED, APPROVED AND ADOPTED at a regular meeting of the Planning Commission of the city of Carlsbad, California, held on the 25th day of August, 1982, by the following vote, to wit: AYES: Commissioners Marcus, Jose, Friestedt NOES:Commissioners Rombotis, Rawlins ABSENT: Chairman Farrow, Commissioner Schlehuber ABSTAIN: None MARY MARCUS, Pro Tern, Chairman CARLSBAD PLANNING COMMISSION ATTEST: MICHAEL J Secretary CARLSBAD PLANNING COMMISSION PC RESO NO. 2014 -2- f APPLICAZ M SUBMITTAL DATE: 1982 STAFF REPORT DATE: August 25, 1982 TO: Planning Commission PROM: Land Use Planning Office • SUBJECT: ZC-262/CT 82-15/CP-212, DAON (ALICANTE HILLS CROSSROADS) -~A Zone Change from R-1-10,000 to RD-M and a 40 lot, 490 unit Tentative Tract Map and Condominium Permit, located on the south side of Corte De La Vista (Alfil Way) east of Alicante Road in La Costa. I. PROJECT DESCRIPTION The applicant is requesting approval of: 1) A zone change from R~1-10,000 to RD-M on a portion of the site; 2) A 40 lot tentative tract map; and 3) A 490 unit condominium permit. The site is located between Corte De La Vista (Alfil Way) and the La Costa Golf Course east of Alicante Road. The property contains 39.2 acres and the project's density would be 12.5 dwelling units per acre which is at the lower end of the General Plan land use range of 10-20 du's/acre designated for this site. The project would be built in four phases moving easterly from Alicante Road. Three unit types are' proposed; 324 hillside units which will be constructed in four large building clusters along the frontage of Corte De La Vista, 134 trails unit which will be placed in four-plex structure running along the edge of the golf course, and 32 split level units which will be located in the middle of the project between the hillside and the trails unit. The project will take access off of Alicante Road at one location and off Corte De La Vista at six locations. Internal circulation will be provided by a combination of private streets and driveways. One of the private streets, Street "A", would provide a continuous through access within the project from Alicante Road to Corte De La Vista. II. ANALYSIS Planning Issues - ZC-262 1) Are the uses allowed in the requested zone consistent with the General Plan and compatible with surrounding land uses and zoning? 52) Will fens-Mouses allowed in the requested zone adversely impact traffic in this vicinity? Discussion Last year, the City Council approved a General Plan Amendment for the subject property (GPA-58(I)) which changed the land use des- ignation from RLM (0-4 du's/acre) to RMH (10-20 du's/acre). The determination at that time was that Corte De La Vista should be the dividing line between higher density development along the golf course and lower density to the north. The requested RDM zone would be consistent with this new designation. Also, a portion of the property, 7 acres on the most westerly portion, is already zoned RDM. Surrounding zoning consist of RDM to the west and northwest, PC to the south and east and R~1-10,000 to the north. Staff's only concern with the zone change involved impacts on traffic and circulation on the surrounding street system. However, a traffic study was prepared which indicated that even with the additional traffic generated by the project, surrounding streets would still be substantially below maximum capacity levels. The study did indicate that the signalization of Alicante and Alga Roads may be warranted at the time the project is completely built out. In summary, staff believes that the zone change is consistent with the General Plan and will be compatible with surrounding zoning and that the required findings for approval of a zone change can be made. Therefore, staff is recommending approval of ZC-262. Planning Issues - CT 82-15/CP-212 . 1) Visual impacts 2) Grading impacts Discussion As proposed, the project meets all of the development and design standards of the Planned Development Ordinance for a condominium project. Both private recreation facilities (balconies and patios) and common recreational facilities will be provided. The common area consists of three active recreation areas dispersed throughout the project. These are well located with respect to the units. Also, all parking, storage, setbacks and other development standards are being met. The internal road system has been designed to provide good circulation while still allowing for some large areas for open space to break-up the dominance of the street system. Staff's primary concern, with respect to the design of the project, involve visual impacts and off site grading impacts. As previously mentioned, the project consists of three unit types. The hillside units are contained in four large building clusters fronting on Corte De La Vista. Each building cluster will be 13 stepped-up the hillside with three, lower levels and three upper levels. Parking will be provided in garages below the units on the lower level and in a two-story parking deck in front of the upper level off of Corte De La Vista. Although each building cluster will be broken-up by stairways, they will appear from a distance as one large massive building. In order to address this concern, the applicant has offset the lower level (3 floors) and the upper level (3 floors) by increasing the separation between the levels and providing dense landscaping between the two levels. Exhibits will be available at the meeting to demonstrate the building separation and landscape treatment. Staff believes that these measures have helped to break-up the massive appearance of the hillside units to an acceptable level. The only other staff concern involves the amount of dirt that will have be exported from the site. The entire site has been previously graded for individual lot development. In order to make the site suitable for one consolidated project, a signif- icant amount of cut grading will have to occur and be exported off-site. Originally the applicant proposed 700,00(H cubic yards of grading. Through redesign, this has been reduced substan- tially, however, 390,000 cubic yards-must be exported off-site. Approximately 80,000 cubic yards is proposed to be exported to Alicante Hills (CT 81-29), an approved tentative map on the north side of Corte De La Vista, and 310,000 cubic yards is proposed to be exported to Alga Hills, 1400 feet to the northwest. The earth moving operation would occur solely on Daon Corporation property but would cross three public streets (See attached Exhibit '0'). The disposal site is vacant and a portion of it has been pre- viously graded to obtain the fill material that was placed on the subject property. It is adjacent to an existing condominium project, however, it was selected because it was previously dis- turbed and it is located close to the subject property. This has reduced the impacts of exporting this much dirt to a location a greater distance from the property. Also, staff has recommended a number of conditions which would help mitigate the impacts of the off-site grading operation. These are contained in the environmental documents for the project and have also been incor- porated into the conditions of approval. With the mitigating measures being incorporated into the project regarding visual and grading impacts, staff feels that the pro- ject complies with the development standards and design criteria of the Planned Development Ordinance and is, therefore, recommending approval of the project. III. ENVIRONMENTAL REVIEW The Land Use Planning Manager has determined that based upon mitigating measures being incorporated into the project, this project will not have a significant effect upon the environment and, therefore, a Conditional Negative Declaration was issued on August 9, 1982. r c V IV. RECOMMENDATION It is recommended that the Planning Commission APPROVE the Con- ditional Negative Declaration issued by the Land Use Planning Manager and ADOPT Resolution Nos. 2013 and 2014, recommending APPROVAL of ZC-262/CT 82-15/CP-212 to the City Council based on the findings and subject to the conditions contained therein. * ATTACHMENTS * 1 PC Resolution Nos. 2013 & 2014 2. Location Map 3. Background Data Sheet 4. Traffic Report from Weston Pringle and Associates, dated June 23, 1982. 5. Disclosure Form 6. Environmental Documents 7. Exhibit "A" - "O", dated August 5, 1982 8. Exhibit "P", dated June 25, 1982 MJH/ar 8/13/82 -4- •LOGCmON. ML ZC-262 APPLICANT ALICANTE HILLS' SIT! VICINITY MAP r <cjr~-~^ ' ^ BACKGROUND DATA SHEET CASE NO: ZC-262/CT 82-15/CP-212 APPLICANT: DAON (ALICANTE HILLS) REQUEST AND LOCATION: Zone change from R-1-10fOOO to RD-M and a 40 lot/490 unit tentative tract map and condominium permit; s/s of Corte de la Vista LEGAL DESCRIPTION: Parcel 2 of Parcel Map 11722 in the City of Carlsbad according to Document No. 81-322184; October 9, 1981 APN; Acres 39.2 Proposed No. of Lots/Units 40 lots/490 units GENERAL PLAN AND ZONING Land Use Designation RMH Density Allowed 10-20 Density Proposed 12.5 du's/Acre Existing Zone R-1-10,000 Proposed Zone RDM Surrounding Zoning and Land Use: Zoning Land Use Site R-1-10,000 & RDM Vacant North RDM Vacant - (approved condominium) South O-S ta Costa Golf Course East P-C Vacant . West RDM Vacant PUBLIC FACILITIES School District San Marcos Water Carlsbad Sewer Leucadia EDU's 490 Public Facilities Fee Agreement, dated ENVIRONMENTAL IMPACT ASSESSMENT X Negative Declaration, issued August 9, 1982 E.I.R. Certified, dated Other, 17 •\v; T »\ A TRAFFIC & TRANSPORTATION ENGINEERING June 23, 1982 Mr. John Brand Rick Engineering Company P.O. Box 1129 Carlsbad, CA 92008 RICK ENG, Date Received 1982 Dear Mr. Brand: This letter summarizes our review of traffic factors related to the proposed Alicante Hills Crossroads project in the La Costa area of the City of Carlsbad. The study is based upon information provided by you, discussions with City Staff and previous studies in the area. The project is located on the southeast corner of Alicante Road and Corte de la Vista (Alf11 Way). A total of 490 condominium units are proposed for the site. In addition to Corte de al Vista, vehicular access is proposed from Alicante Road by a street which parallels Corte de la Vista mid loops to intersect Corte tie la Vista easterly of llolero Struct. The.- site location and road system arc illustrated on Figure 1. EXISTING CONDITIONS • The site is currently undeveloped except for Corte de la Vista which is _constructed and terminates ea.stt-rly of Bolero Street. Construction of 38 single family detached dwelling units has been approved on the north side of Corte de la Vista. Alicante Road/El Fucrte Street is fully improved and loops from Alga Road southwest, of the site to A1j;a Road northwest of the site. CurrcMit daily traffic on Alicante Road at Alga Road is approximately 3300 vehi- cles. The intersection of Alga and Alicante Roads is a "T" intersection with a STOP sign for Alicante Road traffic. Partial development of residential areas . is completed along the Alicante Road/El Fuerte Street corridor. SUITE no • FULLERTOV CALIFORNIA 02031 •371 ?93i PROJECT LOCATION a TRIP DISTRIBUTION W NO SCALE WESTON PPvlNGie RND RSSOCI^TB -2- TRIP GENERATION . • . • In order to examine the traffic factors related to the project, it is necessary to estimate the number of trips that would be generated. Studies have been conducted by government agencies and consultants to determine trip generation characteristics at various land uses. The rates utilized in this study are listed in Table 1 and conform to rates previously utilized in the La Costa • area with some adjustment us requested by the CiLy Traffic Engineer. By applying the rates in Table I to the 490 dwelling units proposed for the site, an estimate of project trip generation is obtained. As indicated in Table 1, the project is estimated to generate 3,900 daily trip ends with 395 occurring during the PM peak hour. TRIP DISTRIBUTION AND ASSIGNMENT Geographic trip distribution patterns have been developed for previous projects in the La Costa area. These previous distributions were reviewed and modified to reflect the anticipated trip distribution for this project. -The project trip distribution is illustrated on Figure 1. By applying the distribution from Figure 1 to the estimated project traffic in Table 1, project traffic was assigned to the road system. Project traffic volumes anticipated on roads in the area are indicated on Figure 2. EXTERNAL TRAFFIC ANALYSIS . Project and project plus existing traffic volumes are indicated on Figure 2 for the external road system. Alicante Road is classified as a Secondary Arterial with a daily capacity of 5,000 to 20,000 vehicles. As indicated on Figure 2, the total daily traffic with the project is less than 6,000 which is well within the capacity of the road. Alga Road is classified as a Major Arterial with a daily of 20,000 to 40,000 vehicles. The anticipated project plus existing volume on Alga Road is less than 10,000 and also well within the capacity of the road. COPY LEGEND 2350 PROJECT (5650) EX/STING + PROJECT ff DAILY VOLUMES WPSTOKi OSIKIf.if PIOUP3E 2 PERIOD -3- Table 1 TRIP GENERATION RATE(1) TRIP ENDS(2) Daily 8.0 3900 PM Peak Hour ln 0.6 295 Out 0.2 100 (1) Trip Ends per Dwelling Unit "(2) Based upon 490 Dwelling Units -4- The need for signalization of Alga Road and Alicante Road was also examined. Warrants for the installation of traffic signals based upon estimated daily volumes have been developed by CalTrans and are listed in Table 2. As indi- cated in Table 2, the project traffic would result in the intersection satis- fying Warrant Number 1, "Minimum Vehicular Traffic". It is recommended that the intersection be signalized prior to full development of the project. Based upon the warrants in Table 2 and the daily volumes on Figure 2, no other intersections would warrant signalization as a result of the project. ON-SITE CIRCULATION The on-site circulation system is restricted by the topography of the site. This restriction results in Corte de la Vista and the parallel road providing internal circulation and access. Connections are planned between these two roads and they intersect east of Bolero Street; however, the grades and align- ments of these connections would not result in their being utilized as principal circulation facilities. These connections do provide routes for emergency vehicles nnd other on—site circulnLlou need:;. The on-site circulation system is illustrated on Figure 3 along with estimated daily and PM peak hour volumes at selected locations. In general, the internal road system is adequate to accommodate project traffic. There are some specific concern?; whcili art: reviewed in the IulJ.ow.iiig* paragraphs. The on-site collector road is proposed to be 26 feet in curb-to-curb width with no parking. This width is adequate to accommodate projected traffic and dis- courage on-street parking. As indicated on Figure 3, volumes increase from east to west on this road. An increase of approximately 50 percent occurs at the first northerly driveway on the collector road. It was recommended by City Staff that a 36 foot width be provided from this driveway westerly. This would allow a left turn pocket for eastbound traffic turning north. We concur with this recommendation to improve traffic operations and safety. 9-6 -6-SIGNALS AND LIGHTING TRAFFIC MANUAL Fiyure 9 1C TRAFFIC SIGNAL WARRANTS (Based on Estimated Average Daily Traffic — See Note 2) URBAN 1. Minimum Vehicular Soti sf i fd . ... RURAL x * Number of lanes for moving traffic on each approach Major Street Minor Street 1 1 2 or more . .7.000. . . V 1 . . 230Q 2 or more 2 or niore ..... . . 2. Interruption of Continuous Traffic Number of loncs for mo viny traffic on each approach Major Street Minor Slu-ct 1 1 2 or more 7000. . . 2 or more . , 1 3. Combination No one warrant satisf • fulfilled SOfc or more 1 .2800 .... 2 or more 2 ot more .... ... * led but following warrants 1 2 Minimum Requirements EADT Vehicles per day on mojoi street (total of both approaches) Urban Rural 8.000 5.600 9,600 6.720 9,600 6,720 8,000 5,600 Vehicles per day on major street (total of both approaches) Uilxm Ruiul • 12.000 8.400 14,400 10,030 14.400 10.030 12,000 8,400 2 Warrants Vchiclesptrdoy on higher— volume minor- street approach (one direction only) Urban Rural 2,400 1.680 2,400 1,680 3,200 2.240 3.200 2.240 Vehicles per day on higher- volume minor-street approach (one direction only) Urlxm Rurut 1.200 850 "1.200 850 1,600 1,120 1.600 1.120 2 Warrants NOTE: 1. Left turn movements from the major street may be included with minor street volumes if o st-porote signal phase is to be provided for the left-turn movement. 2. To be used only for NEW INTERSECTIONS or other locations where actual traffic volumes conoot be counted. IS-IC^C COPY I75O DAILY VOLUMES 135/45 PM PEAK IN / PM PEAK OUT ON-S/TZ CIRCULATION a VOLUMES 15'MINIMUM TANGENT TURN CHANNELIZATION WESTON PRINGli BND RSSQCiBTIS -*" The collector road has a relatively long tangent section which could result in speeding problems. Designs of this type generally result in complaints from adjacent residents of excessive speed. In order to mitigate this potential problem, it is recommended that median islands be placed along this section to reduce the travel way and speeds. The design of these islands should be * reviewed and approved by the City Engineer. A final concern is the lack of a tangent section on the collector road at its intersection.with Corte de la Vista. The normal tangent section cannot be provided due to topography and grading restrictions. Due to the minor traffic volumes on both Corte de la Vista and the collector at this point, the lack of a standard tangent is not felt to be a significant problem. It is recommended that a minimum of 15 feet of tangent be provided to increase the safety of this intersection. SUMMARY This study has examined the traffic factors related to the proposed Alicante Hills Crossroads project in the La Costa area of the City of Carlsbad. Esti- mates have been made of trip's to be generated by the project and their po- tential impact upon the road system evaluated. On-site circulation was also examined and recommendations developed to improve traffic operations and safety. In genera], the project was found to be acceptable from ;i traffic circulation and safety viewpoint, with the recommended mitigation measures. Principal findings of the study are the following: 1. The project would generate 3,900 daily trip ends with 395 occurring during the PM peak hour. ' . 2. The existing external road system has adequate capacity available to accommodate the development traffic. 3. On-site circulation provisions were found to be adequate with the recommended mitigation measures. -( ' MITIGATION MEASURES The following measures are recommended to mitigate potential traffic impacts from the development. 1. Signalization of the Alga Road/Alicante Road intersection would be warranted at the completion of this development . 2. The iiiLeruaJ collector road should have a 36 foot curb-to-curb width from Alicante Road to the first northerly driveway to allow separate left turn lanes. 3. Islands should be installed on the internal collector to reduce the travel way and speeds at selected locations and as approved by the City Engineer. 4. A minimum tangent of 15 feet should be provided on the collector road at its intersection with Corte de la Vista. * * * * * * ** * We trust that this report will be of assistance to you in the development of this project. If you have a'ny questions or require additional information, please contact us. Respectfully submitted, WESTON PRINGLE & ASSOCIATES Weston S. Pringle, P.E. Registered Professional Engineer State of California Numbers C16828 & TR 565 WSPrbas #1351 .' -that further informatiof' . required, you will be so ad/* .d. * iadte.^ .._^3*»_._ APPLICANT: DAON CORPORATION AGENT: MEMBERS Name (individual, partnership, joint venture, corporation, syndication) 1241 Elm Avenue, Carlsbad, Ca. 92008 • Business Address Telephone Number James L. Goff Name 1241 Elm Avenue, Carlsbad, Ca. 92008 Business Address 43^578 Telephone Number Name -(individual, partner, joint venture, corporation, syndication) Home Address Business Address Telephone Number Telephone Number Home Address Business Address Telephone Nuaber Telephone Number ; (Attach more sheets if necessary) declare under penalty of perjury that the information contained in this dis- closure is true and correct and that it will remain true and correct and may be- rolled upon as being true and correct until amended. BEST COPY DAON CORPORATION ^Applicant ALICANTE HILLS fD)f] /SvfNl !T 1 I I I1— |//—v\||\| U PROPOSED LAND USE RDM HILLSIDE UNITS 324 SPLIT LEVEL 32 TRAILS UNITS 137 NO. OF UNITS 493 UNITS AREA 39.2 AC DENSITY 12.6 UNITS/AC. 850,746 SF 1109 SPACES LAUNDRY FACILITIES IN UNIT STORAGE 480 CU. FT. (SEE PLANS) ROSS IKEMIRE / ARCHITECTS INC.12120 HILLCREITRO-tUITI 21>-D*LLA1, THAI 711 JO'll HI IJ1-O9TJ LFLJ==Ltl J=i 1= eie ti *o 100 DAON CORPORATION 1241 ELM AVENUE CARLSBAD, CALIF. RECK ENGINEERING 3088 PIO PICO DRIVE CARLSBAD, CALIF. ALICANTE HILLS ROSS IKEMIRE / ARCHITECTS INC.12110 HILLCmtt WJ •«urri 1K-OALLAI. T1XA1 7M30-I114I JJ3-097I RICK ENGINEERING 3088 PIO PICO DRIVE CARLSBAD, CALIF. DAON CORPORATION CARLSBAD. CALIF.1241 ELM AVENUE j 1514 SF ' I 1448 SF ' L 1409 SF - L 1188 SF = : TCMOIU T^ Zk ROSS IKEMIRE / ARCHITECTS INC.VrV •• luioHuciiuTn-iuniit-iiALLAt, nx*i riiu-ui4tm-oiTi STORAGE IX QAR«OE DAON CORPORATION 1241 ELM AVENUE CARLSBAD, CALIF. m 1348 SF- oi m o«m>gt ROSS IKEMIRE/ ARCHITECTS INC.lltKMUCmiTKO'KJinilCOALLU, TEUU 7I1U-I114) <U-O«ri DAON CORPORATION 1241 ELM AVENUE CARLSBAD, CALIF. RICK ENGINEERING 3088 PIO PICO DRIVE CARLSBAD, CALIF. r1 ^^J. uv;^c^k . .\ . •. ,•,-.-,-.•- x,y--v, , .-...s- "•• \! '$*'"':•4 i,"' *< •^f^^.-r. ss^J*' J^.^'*" - \^.,r^-^S*S~sf,f.fJ,-: '••'?.*"• - ^'*»^;'fi;:-2:z;:z:z.-• - •••• V''"V/X ••"••"*• -«./«.«. -, ', \ x \ v -. N s ^S-^TJ^'w*^ ,- .-.^ .- .,,; «ff- « '- '..-.• t- . rr .,ii. ii > 1 t V t T » s Fn ^ /- ^v^w^.^^C-•>'V'-'N^''.'>•';"•'••''';';*"'n£\ -;cx^$c^^X: -^;^: ^? "^ ^" ^fe^: ;-\ %-•: ^C< *>>-*N '\'^ ZC 262 EXHIBIT A