HomeMy WebLinkAbout2016-02-03; Planning Commission; ; PUD 15-19/SDP 15-21/CDP 15-41/MS 15-14 – 3450 GARFIELD STREET
The City of Carlsbad Planning Division
A REPORT TO THE PLANNING COMMISSION
Item No.
Application complete date: October 20, 2015
P.C. AGENDA OF: February 3, 2016 Project Planner: Chris Garcia
Project Engineer: Tecla Levy
SUBJECT: PUD 15-19/SDP 15-21/CDP 15-41/MS 15-14 – 3450 GARFIELD STREET – Request for
approval of a Planned Development Permit, Site Development Plan, Coastal
Development Permit, and Tentative Parcel Map to demolish an existing single-family
home and to allow for the development of a three-unit multiple-family residential air-
space condominium project on a 0.15 acre infill site located at 3450 Garfield Street,
within the Mello II Segment of the Local Coastal Program and Local Facilities
Management Zone 1. The project site is not within the appealable area of the California
Coastal Commission. The City Planner has determined that this project is exempt from
the requirements of the California Environmental Quality Act (CEQA) pursuant to
Section 15332 “In-Fill Development Projects” of the State CEQA Guidelines and will not
have any adverse significant impact on the environment.
I. RECOMMENDATION
That the Planning Commission ADOPT Planning Commission Resolution No. 7147 APPROVING Planned
Development Permit (PUD 15-19), Site Development Plan (SDP 15-21), Coastal Development Permit
(CDP 15-41), and Tentative Parcel Map (MS 15-14), based upon the findings and subject to the
conditions contained therein.
II. PROJECT DESCRIPTION AND BACKGROUND
The applicant proposes to demolish an existing single-family home and to develop a three-unit multiple-
family residential air-space condominium project on a 0.15 acre infill site within the Mello II Segment of
the Local Coastal Program and the Beach Area Overlay Zone (BAOZ). More specifically, the site is
located at 3450 Garfield Street on the east side of the street. The development of the proposed
condominium project requires the processing and approval of a Planned Development Permit, Site
Development Plan, Coastal Development Permit and Tentative Parcel Map. The subdivision is
considered minor and requires a parcel map (MS – minor subdivision) because it involves the division of
land into four or fewer condominiums.
Topographically, the site has a gentle slope downward from west to east with the west property line
elevation approximately 59 feet above mean sea level (MSL) and the east property line elevation
approximately 54 feet above MSL. The site is developed with one existing single-family home and does
not contain any sensitive vegetation.
The proposed project contains one, two-story building above a basement parking garage. The basement
garage includes two parking spaces per unit and one visitor parking space for a total of seven parking
spaces. The basement also includes storage areas for each unit. Access to the underground parking is
from a 12 foot wide driveway along the south side of the property. Two of the units are single level with
one unit occupying each of the two floors. The remaining unit is located on the east side of the building
and contains living area on both floors. Two of the homes have similar floor plans consisting of three
3
PUD 15-19/SDP 15-21/CDP 15-41/MS 15-14 – 3450 GARFIELD STREET
February 3, 2016
Page 2
bedrooms and approximately 2,000 square feet. The remaining two-level home also has three
bedrooms and is also approximately 2,000 square feet. The front entries of the homes are located on
the north side of the building and each unit includes patios or balconies and a roof deck area. The
underlying lot will be held in common interest between the three airspace condominiums. This
common area includes, but is not limited to, the guest parking area and landscaping.
The project is beach contemporary architecture. Primary building materials include cement plaster with
acrylic finish and sand finish texture, horizontal wood siding, and stone tile. Asphalt composite shingles
cover a 3:12 pitched roof over each unit and a painted metal railing or glass rail with metal cap is
included around the balconies and roof deck areas.
Table “A” below includes the General Plan designations, zoning and current land uses of the project site
and surrounding properties.
TABLE A
Location General Plan Designation Zoning Current Land Use
Site
R-23 Residential 15-23 du/ac
with a Growth Management
Control Point (GMCP) of 19
du/ac.
Multiple-Family Residential
(R-3) Zone with Beach Area
Overlay Zone (BAOZ)
One single-family home.
North R-23 Residential R-3 with BAOZ Single-family residential
South R-23 Residential R-3 with BAOZ Two-family residential
East R-23 Residential R-3 with BAOZ Multiple-family residential
West R-23 Residential R-3 with BAOZ Single-family residential/
Multiple-family residential
Table “B” below includes the project site’s gross and net acreage, the number of dwelling units allowed
by the General Plan’s Growth Management Control Point (GMCP) density and the proposed projects
number of dwelling units and density.
TABLE B
Gross Acres Net Acres DUs Allowed at GMCP
Density
DUs Proposed and
Project Density
0.15 acres 0.15 acres 2.9 units 3 units at 20 du/ac
In order to meet the City’s Inclusionary Housing requirements, the project is conditioned to pay an
affordable housing in-lieu fee on a per unit basis for two units, or three units if building permits for the
three-unit project have not been applied for within two years of demolishing the existing single-family
home on-site.
Project grading quantities are 863 cubic yards of cut and 863 cubic yards of export.
The project meets the City’s standards for planned developments and subdivisions, and as designed and
conditioned, is in compliance with the General Plan, Subdivision Ordinance, and relevant zoning
regulations of the Carlsbad Municipal Code (C.M.C).
PUD 15-19/SDP 15-21/CDP 15-41/MS 15-14 – 3450 GARFIELD STREET
February 3, 2016
Page 3
III. ANALYSIS
The project is subject to the following regulations:
A. R-23 Residential General Plan Land Use designation;
B. Multiple-Family Residential (R-3) Zone, Planned Development Regulations and Beach Area
Overlay Zone (BAOZ) (C.M.C. Chapters 21.16, 21.45 and 21.82);
C. Mello II Segment of the Local Coastal Program;
D. Subdivision Ordinance (C.M.C. Title 20);
E. Inclusionary Housing Ordinance (C.M.C. Chapter 21.85); and
F. Growth Management Ordinance (C.M.C. Chapter 21.90) and Zone 1 Local Facilities Management
Plan.
The recommendation for approval of this project was developed by analyzing the project’s consistency
with the applicable regulations and policies. The project’s compliance with each of the above
regulations is discussed in detail in the sections below.
A. General Plan R-23 Residential High Density Land Use Designation
The General Plan Land Use designation for the property is R-23 Residential (R-23). The R-23 designation
allows residential development at a density range of 15-23 dwelling units per acre with a Growth
Management Control Point (GMCP) of 19 dwelling units per acre. The project site has a net developable
acreage of 0.15 acres. The project’s proposed density of 20 du/ac is within the R-23 density range of 15-
23 du/ac and above the 15 du/ac that is used for the purpose of calculating the City’s compliance with
Government Code Section 65863. At the GMCP, 2.9 dwelling units, or 3 when rounded up per C.M.C.
Section 21.53.230(e), would be permitted on this 0.15 net developable acre property. Although the
project exceeds the GMCP for the R-23 General Plan Land Use designation by the fractional unit
allocation of 0.1 dwelling units, the General Plan Land Use Element allows the City to approve residential
development at a density that exceeds the GMCP for the applicable density range provided the
proposed residential development complies with certain findings as discussed below.
To exceed the GMCP, the project must be consistent with the following required General Plan findings:
1) that the project qualifies for and will receive an allocation of “excess” dwelling units, pursuant to City
Council Policy No. 43; 2) that there have been sufficient residential projects approved at densities below
the GMCP so the citywide and quadrant dwelling unit limits will not be exceeded as a result of the
proposed project; and, 3) all necessary public facilities required by the Citywide Facilities and
Improvements Plan will be constructed, or are guaranteed to be constructed, concurrently with the
need for them created by this development and in compliance with the adopted City standards. The
proposed project is consistent with the above required findings in that there have been sufficient
developments in the northwest quadrant that have developed at densities below the GMCP such that
the allocation of 0.1 dwelling units would not result in exceeding the quadrant limit, the project is
conditioned to pay the appropriate fees to comply with City’s Growth Management Program, and the
City’s public facilities plans will not be adversely impacted as the allocation of 0.1 units has already been
analyzed and anticipated within the northwest quadrant.
Furthermore, pursuant to City Council Policy No. 43 – Proposition E “Excess Dwelling” Unit Bank, in
approving a request for an allocation of excess dwelling units, the following three findings must also be
made:
PUD 15-19/SDP 15-21/CDP 15-41/MS 15-14 – 3450 GARFIELD STREET
February 3, 2016
Page 4
1) That the project location and density are compatible with existing adjacent residential
neighborhoods and/or nearby existing or planned uses;
2) That the project location and density are in accordance with the applicable provisions of the
General Plan and any other applicable planning document; and
3) That the project complies with the findings stated in the General Plan Land Use Element for
projects that exceed the GMCP for the applicable density range.
The proposed project is consistent with the above required findings for the allocation of excess dwelling
units in that: 1) the project is located within a Residential High General Plan Land Use designation (R-23
is equivalent to and replaced the Residential High General Plan Land Use Designation) and Multiple-
Family Residential (R-3) zone, which consists of single-family homes as well as attached multiple-family
residential condominiums and apartment buildings that are approved at a similar density (15-23 du/ac)
as the density of the proposed project (20 du/ac), 2) that the project’s location and density described
above are in accordance with the applicable provisions of the General Plan for the R-23 Residential Land
Use designation, and 3) that the project complies with the findings stated in the General Plan Land Use
Element for projects that exceed the growth management control point (19 du/ac) for the R-23
Residential Land Use designation as discussed above.
Lastly, the project complies with the Elements of the General Plan as outlined in Table “C” below:
TABLE C – GENERAL PLAN COMPLIANCE
ELEMENT
USE, CLASSIFICATION,
GOAL, OBJECTIVE OR
PROGRAM
PROPOSED USES & IMPROVEMENTS COMPLIANCE
Land Use &
Community
Design
Site is designated R-23
Residential, (R-23; 15-23
du/ac) with a GMCP of 19
du/ac. 2.9 dwelling units
(3 when rounded up)
could be constructed on
the site at the GMCP (0.15
acres x 19 du/ac).
The residential project density at 20
dwelling units per acre (3 DUs) is within the
R-23 Residential density range of 15-23
du/ac and above the R-23 Residential
minimum of 15 du/ac used for the purpose
of calculating the City’s compliance with
Government Code Section 65863.
However, the project is 0.1 dwelling units
above the GMCP and therefore 0.1 dwelling
units will be withdrawn from the City’s
excess dwelling unit bank consistent with
City Council Policy No. 43.
Yes
Housing Provisions for affordable
housing.
The project is conditioned to pay an in in-
lieu fee on a per unit basis for two units, or
three units if building permits for the three-
unit project have not been applied for
within two years of demolishing the
existing single-family home on-site.
Yes
Public Safety Reduce fire hazards to an
acceptable level.
The project site is located within a five
minute response time of Fire Station No. 1
and has been designed to comply with the
fire code, including provisions for an
automatic sprinkler system within each
dwelling unit.
Yes
PUD 15-19/SDP 15-21/CDP 15-41/MS 15-14 – 3450 GARFIELD STREET
February 3, 2016
Page 5
TABLE C – GENERAL PLAN COMPLIANCE (CONTINUED)
ELEMENT USE, CLASSIFICATION,
GOAL, OBJECTIVE OR
PROGRAM
PROPOSED USES & IMPROVEMENTS
COMPLIANCE
Open Space,
Conservation
& Recreation
Minimize the
environmental impacts to
sensitive resources within
the City.
Utilize Best Management
Practices for control of
storm water and to
protect water quality.
The project will not create any
environmental impacts to the previously
graded and developed site.
The project is conditioned to conform to all
NPDES requirements and has been
designed to include Low Impact Design
(LID) elements.
Yes
Noise Require that a "Noise"
Study be submitted with
all discretionary
applications for residential
projects of five or more
single-family dwelling
units or any multiple-
family dwelling units
located within or 500-feet
beyond the 60 dB(a) CNEL
noise contour lines as
shown on Map 2: Future
Noise Exposure Contour
Map.
A Noise Study (October 19, 2015) was
prepared by Dr. Penzes & Associates, to
address any potential noise impacts
occurring as a result of the project sites
close proximity to Carlsbad Boulevard and
the railroad tracks to the east. To achieve
the 45 dB(a) CNEL interior noise standard,
the noise study includes construction
design standards (window closed
conditioning and window design) to be
incorporated at the building construction
phase. The project has been conditioned to
incorporate these design standards into the
building design prior to the issuance of
building permits. The parapet wall around
the roof decks reduces the noise level to
below the 60 dB(a) exterior noise standard
for private recreation areas.
Yes
Mobility Construct roadway
improvements needed to
serve proposed
development.
All public facilities including curb, gutter
and sidewalk are conditioned to be built or
reconstructed along the property frontage
(Garfield Street).
Yes
B. Multiple-Family Residential (R-3) Zone, Planned Development Regulations, and Beach Area
Overlay Zone (BAOZ)
The proposed project is required to comply with all applicable land use and development standards of
the Carlsbad Municipal Code (C.M.C.) including the Multiple-Family Residential (R-3) Zone (C.M.C.
Chapter 21.16), Planned Developments (C.M.C. Chapter 21.45), and the Beach Area Overlay Zone
(BAOZ)(C.M.C. Chapter 21.82).
The three-unit multiple-family residential air-space condominium project meets or exceeds the
requirements of the R-3 Zone and the BAOZ as outlined in Table “D” below. The Planned Development
regulations provide most of the development standards with the exception of those listed in the table
below. The project complies with all applicable development standards for Planned Developments
(C.M.C Chapter 21.45). Please refer to Attachment No. 4 for an analysis of project compliance with
Tables C & E of the Planned Development regulations.
PUD 15-19/SDP 15-21/CDP 15-41/MS 15-14 – 3450 GARFIELD STREET
February 3, 2016
Page 6
Table D – BAOZ AND R-3 COMPLIANCE
BAOZ Standards Required Proposed Comply
Building Height 30 feet with minimum 3:12
roof pitch is provided or 24
feet if less than a 3:12 roof
pitch is provided
Roof Peak = 30″ w/ 3:12 roof pitch
Decks = <24 ft.
Yes
R-3 Standards Required Proposed Comply
Setbacks Interior Side: 5’ – 10% Lot
Width
Rear: 10’ – 20% Lot Width
Interior Side 5’
Rear: 10’ – 15’
Yes
Lot Coverage 60% 60% Yes
C. Local Coastal Program
The proposed site is located outside of the appeals area of the City’s Coastal Zone and lies within the
Mello II Segment of the Local Coastal Program.
The project site has an LCP Land Use designation of RH and Zoning of R-3, which are consistent with the
City’s General Plan and Zoning. The projects consistency with the R-23 Residential General Plan Land
Use designation is analyzed in Section “A,” Table “C” above.
The proposed project is consistent with the Mello II Segment of the Local Coastal Program which
contains land use policies for development and conservation of coastal land and water areas within its
boundaries. The policies of the Mello II Segment emphasize topics such as preservation of agriculture
and scenic resources, protection of environmentally sensitive resources, provision of shoreline access
and prevention of geologic instability and erosion.
The project is consistent with the coastal act policies as follows: a) no agricultural lands exist on the
project site, therefore no impacts to such will occur; b) the site does not contain or impact
environmentally sensitive habitats, water or marine resources; c) the site is geologically stable and the
proposed grading for the site has been limited to the area necessary to develop the site; d) the project
has been designed to reduce the amount of off-site runoff and has been conditioned to implement the
NPDES standards to ensure the quality of the water leaving the site; e) the project meets the parking
requirements for a three-unit multiple-family airspace condominium project; f) the project does not
preclude any recreational opportunities or shoreline access as the property is located on the east side of
Carlsbad Boulevard; and, g) the development of a three-unit multiple-family residential air-space
condominium will not obstruct views of the coastline as seen from public lands or public right-of-way.
Given the above, the project is consistent with the Mello II segment land use policies.
D. Subdivision Ordinance
The Land Development Engineering Division has reviewed the proposed Tentative Parcel Map and has
found that the subdivision complies with all applicable requirements of the Subdivision Map Act and the
City’s Subdivision Ordinance (Title 20) for Minor Subdivisions. The subdivision is considered minor
because it involves the division of land into four or fewer condominiums. The project has been
conditioned to install all infrastructure-related improvements and the necessary easements for these
improvements concurrent with the development.
PUD 15-19/SDP 15-21/CDP 15-41/MS 15-14 – 3450 GARFIELD STREET
February 3, 2016
Page 7
E. Inclusionary Housing Ordinance
For all residential development less than seven units, the inclusionary housing requirement may be
satisfied through the payment of an inclusionary housing in-lieu fee. However, pursuant to Carlsbad
Municipal Code Section 21.85.030D.3., the construction of a new residential structure which replaces a
residential structure that was destroyed or demolished within two years prior to the application for a
building permit for the new residential structure is exempt from affordable housing requirements,
provided that the number of residential units is not increased from the number of residential units of
the previously destroyed or demolished residential structure. The proposal to demolish one existing
single-family home and construct a three-unit residential condominium project has been conditioned to
pay the applicable housing in-lieu fee on a per unit basis for two units, or three units if building permits
for the three-unit project have not been applied for within two years of demolishing the existing single-
family home on-site.
F. Growth Management
The proposed project is located within Local Facilities Management Zone 1 in the northwest quadrant of
the City. The impacts on public facilities created by the project, and its compliance with the adopted
performance standards, are summarized in Table “F” below.
TABLE F – GROWTH MANAGEMENT COMPLIANCE
STANDARD IMPACTS COMPLIANCE
City Administration 10.43 sq. ft. Yes
Library 5.57 sq. ft. Yes
Waste Water Treatment 3 EDU Yes
Parks 0.021 acre Yes
Drainage .119 - .546 CFS Yes
Circulation 24 ADT (14 net increase) Yes
Fire Station No. 1 Yes
Open Space 0 acres N/A
Schools Carlsbad (E=.5124/M=.1698/HS = .2199) Yes
Sewer Collection System 3 EDU Yes
Water 1650 GPD Yes
The project proposes 3 dwelling units whereas the unit yield at the GMCP of the property is 2.9 dwelling
units. The proposed 3-unit project is 0.1 units above the Growth Management Control Point density for
this R-23 Residential designated property. Consistent with the General Plan and Policy No. 43, 0.1
dwelling units will be withdrawn from the City’s excess dwelling unit bank.
IV. ENVIRONMENTAL REVIEW
The City Planner has determined that the project belongs to a class of projects that the State Secretary
for Resources has found do not have a significant impact on the environment, and it is therefore
categorically exempt from the requirement for the preparation of environmental documents pursuant
to Section 15332 (In-Fill Development Projects) Class 32 Categorical Exemption of the State CEQA
Guidelines. The project is consistent with the General Plan as well as with the Zoning Ordinance, the
project site is within the city limits, is less than 5 acres in size, and is surrounded by urban uses; there is
no evidence that the site has value as habitat for endangered, rare, or threatened species; approval of
PUD 15-19/SDP 15-21/CDP 15-41/MS 15-14 – 3450 GARFIELD STREET
February 3, 2016
Page 8
the project will not result in significant effects relating to traffic, noise, air quality, or water quality; and
the site can be adequately served by all required utilities and public services. In making this
determination, the City Planner has found that the exceptions listed in Section 15300.2 of the state
CEQA Guidelines do not apply to this project. A Notice of Exemption will be filed by the City Planner
upon final project approval.
ATTACHMENTS:
1. Planning Commission Resolution No. 7147
2. Location Map
3. Disclosure Statement
4. Planned Development Tables C & E
5. City Council Policy No. 66 Compliance Table
6. Reduced Exhibits
7. Full Size Exhibits “A – O” dated February 3, 2016
G
A
R
F
I
E
L
D
S
T
C
A
R
L
S
B
A
D
B
L
JUNIPER AVLI
N
C
O
L
N
S
T
CHESTNUT AVWALNUT AVSYCAMORE AVMAPLE AVACACIA AVCHERRY AVVI
L
L
A
G
E
D
R
PUD 15-19 / SDP 15-21 / CDP 15-41 / MS 15-143450 Garfield Street
SITE MAP
JPALOMARAIRPORTRD
E
L
C
AMREALL A COSTA AV
C
A
R
L
S
B
A
D
B
LELCAMINOREAL MELR
O
S
E
DRAVIARAPY
RANCHOS ANTAFERDCOLLEGEBLSITE
PACIFICOCEAN
ATTACHMENT NO. 4
PLANNED DEVELOPMENTS (CMC SECTION 21.45.060)
TABLE C: GENERAL DEVELOPMENT STANDARDS
APPLICABLE TO ALL PLANNED DEVELOPMENTS
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
C.1 Density
Per the underlying General Plan designation. When two or more general plan land use designations exist within a planned development, the density may be transferred from one general plan designation to another with a general plan
amendment.
N/A
C.2 Arterial Setbacks
All dwelling units adjacent to any arterial road shown on the Circulation Element of the General Plan shall maintain the following minimum setbacks from the right-
of-way: Prime Arterial 50 Feet Major Arterial 40 Feet Secondary Arterial 30 Feet
Carlsbad Boulevard 20 Feet
N/A
Half (50%) of the required arterial setback area located closest to the arterial shall
be fully landscaped to enhance the street scene and buffer homes from traffic on adjacent arterials, and:
Shall contain a minimum of one 24” box tree for every 30 lineal feet of
street frontage; and
Shall be commonly owned and maintained
N/A
Project perimeter walls greater than 42 inches in height shall not be located in the required landscaped portion of the arterial setback, except noise attenuation walls that:
Are required by a noise study, and Due to topography, are necessary to be placed within the required landscaped portion of the arterial setback.
N/A
C.3
Permitted Intrusions into Setbacks/ Building Separation
Permitted intrusions into required building setbacks shall be the same as specified in Section 21.46.120 of this code. The same intrusions specified in Section
21.46.120 shall be permitted into required building separation.
Pursuant to C.M.C. Section 21.46.120 balconies and roof eaves are permitted to encroach up to two feet into the required setback. The proposed project
has balconies and eaves that project no more than the permitted two feet. Project complies.
C.4 Streets
Private
Minimum right-of-way width 56 feet
N/A
Minimum curb-to-curb width 34 feet
Minimum parkway width (curb adjacent) 5.5 feet, including curb
Minimum sidewalk width 5 feet (setback 6 inches from property line)
Public
Minimum right-of-way width 60 feet
N/A
Minimum curb-to-curb width 34 feet
Minimum parkway width (curb
adjacent) 7.5 feet, including curb
Minimum sidewalk width 5 feet (setback 6 inches from
property line)
Street Trees
within parkways
One-family dwellings and twin
homes on small-lots
A minimum of one street tree (24-inch box) per lot is required to be
planted in the parkway along all streets.
N/A
Condominium projects Street trees shall be spaced no further apart than 30 feet on center within the parkway.
One street tree is shown along the 50’ frontage on the conceptual landscape plan and shall be required with the final landscape plan.
Tree species should be selected to create a unified image for the street, provide an effective canopy, avoid sidewalk damage and minimize water consumption.
The street tree proposed is consistent with the city’s Landscape Manual.
PLANNED DEVELOPMENTS (CMC SECTION 21.45.060)
TABLE C: GENERAL DEVELOPMENT STANDARDS
APPLICABLE TO ALL PLANNED DEVELOPMENTS
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
C.5 Drive-
aisles
3 or fewer dwelling units
Minimum 12 feet wide when the drive-aisle is not required for emergency vehicle access, as determined by the Fire Chief. A 12 foot driveway is provided to the subgrade parking basement. If the drive-aisle is required for emergency vehicle access, it shall be a minimum of 20 feet wide. 4 or more dwelling units Minimum 20 feet wide. N/A
All projects
No parking shall be permitted within the minimum required width of a drive-aisle.
Project does not propose any parking within the 12 ft. wide driveway. Project
complies.
A minimum 24-foot vehicle back-up/maneuvering area shall be provided in front of garages, carports or uncovered parking spaces (this may include driveway area, drive-aisles, and streets).
Each parking space, including the visitor parking space includes a minimum 24 ft. vehicle back-up/maneuvering area behind each space. Project complies.
Additional width may be required for vehicle/emergency vehicle maneuvering area. N/A
Parkways and/or sidewalks may be required. N/A
No more than 24 dwelling units shall be located along a single-entry drive-aisle. N/A
All drive-aisles shall be enhanced with decorative pavement. Project driveway has been enhanced with decorative pervious pavers. Project complies.
C.6
Number of Visitor Parking
Spaces Required (1)
Projects with 10 units or fewer A .30 space per each unit. Project proposes three (3) units. At 0.30 spaces per unit, a three-unit requires .9 space or 1 space based on
rounding up to the nearest whole number. Project provides one (1) visitor parking space. Project complies.
Projects 11 units or more A .25 space per each unit.
When calculating the required number of visitor parking spaces, if the calculation results in a fractional parking space, the required number of visitor parking spaces shall always be rounded up to the nearest whole number.
C.7
Location of Visitor Parking
On Private/
Public Streets
On-street visitor parking is permitted on private/public streets, subject to the following:
The private/public street is a minimum 34-feet wide (curb-to-curb)
There are no restrictions that would prohibit on-street parking where
the visitor parking is proposed
The visitor parking spaces may be located:
o Along one or both sides of any private/public street(s) located
within the project boundary, and
o Along the abutting side and portion of any existing public/private street(s) that is contiguous to the project boundary
N/A
In parking bays along public/private streets within the project boundary, provided the parking bays are outside the minimum required street right-of-way width. N/A
When visitor parking is provided as on-street parallel parking, not less than 24 lineal feet per space, exclusive of driveway/drive-aisle entrances and aprons, shall be provided for each parking space,
except where parallel parking spaces are located immediately adjacent to driveway/drive-aisle aprons, then 20 lineal feet may be provided.
N/A
Within the Beach Area Overlay Zone, on-street parking shall not count toward meeting the visitor parking requirement.
Project is located within the BAOZ. All required visitor parking is being provided onsite. Project complies.
On
Drive-aisles
Visitor parking must be provided in parking bays that are located
outside the required minimum drive-aisle width.
Project proposes one (1) visitor parking space on-site provided in a parking
space that is located outside of the required minimum driveway width. Project complies.
On a Driveway
Outside the Beach Area Overlay
One required visitor parking space may be credited for each driveway in a project that has a depth of 40 feet or more. N/A
PLANNED DEVELOPMENTS (CMC SECTION 21.45.060)
TABLE C: GENERAL DEVELOPMENT STANDARDS
APPLICABLE TO ALL PLANNED DEVELOPMENTS
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
Zone For projects with 10 or fewer units, all required visitor
parking may be located within driveways (located in front of a unit’s garage), provided that all dwelling units in the project have driveways with a depth of 20 feet or more.
N/A
Within the Beach Area
Overlay Zone
One required visitor parking space may be credited for each driveway in a project that has a depth of 40 feet or
more.
N/A
If the streets within and/or adjacent to the project allow for on-street parking on both sides of the street, then visitor parking may be located in a driveway, subject to the following: All required visitor parking may be located within driveways (located in front of a unit’s garage), provided that all dwelling units in the project have
driveways with a depth of 20 feet or more.
If less than 100% of the driveways in a project have a depth of 20 feet or more, then a .25 visitor parking space will be credited for each driveway in a project that has a depth of 20 feet or more (calculations resulting in a fractional parking space credit shall
always be rounded down to the nearest whole number).
N/A
All projects
The minimum driveway depth required for visitor parking (20 feet or 40 feet) applies to driveways for front or side-loaded garages, and is measured from the property line, back of sidewalk, or from the edge of the drive-aisle,
whichever is closest to the structure.
N/A
Compact Parking
For projects of more than 25 units, up to 25% of visitor parking may be provided as compact spaces (8 feet by 15 feet). No overhang is permitted into any required setback area or over sidewalks less than 6 feet wide.
N/A
For all projects within the Beach Area Overlay Zone, up to 55% of the visitor parking may be provided as compact spaces (8 feet by 15 feet).
The visitor parking space is a standard space with a minimum dimension of 8.5 ft. x 20 ft. Project complies.
Distance from unit
Visitor parking spaces must be located no more than 300 feet as measured in a logical walking path from the entrance of the unit it could be considered to serve.
Distance from visitor parking spaces to the furthest unit is less than 300 ft. Project complies.
C.8 Screening of Parking
Areas
Open parking areas should be screened from adjacent residences and public rights-of-way by either a view-obscuring wall, landscaped berm, or landscaping,
except parking located within a driveway.
All parking spaces are located in a basement. No open parking areas
exist. Project complies.
PLANNED DEVELOPMENTS (CMC SECTION 21.45.060)
TABLE C: GENERAL DEVELOPMENT STANDARDS
APPLICABLE TO ALL PLANNED DEVELOPMENTS
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
C.9
Community
Recreational Space (1)
Community recreational space shall be provided for all projects of 11 or more dwelling units, as follows:
N/A Minimum community recreational space required
Project is NOT within R-23 general plan designation 200 square feet per unit
Project IS within R-23 general plan designation 150 square feet per unit
Projects with 11 to 25 dwelling units Community recreational space shall be provided as either (or both) passive or active recreation facilities. N/A
Projects with 26 or more dwelling units
Community recreational space shall be provided as both passive and active recreational facilities with a minimum of 75% of the area allocated for active facilities. N/A
Projects with 50 or more dwelling units
Community recreational space shall be provided as both
passive and active recreational facilities for a variety of age groups (a minimum of 75% of the area allocated for active facilities).
N/A
For projects consisting of one-family dwellings or twin homes on small-lots, at least 25% of the community recreation space must be provided as pocket parks.
Pocket park lots must have a minimum width of 50 feet and be located at strategic locations such as street intersections (especially “T-intersections”) and where open space vistas may be achieved.
N/A
All projects
(with 11 or more dwelling units)
Community recreational space shall be located and designed so as to be functional, usable, and easily accessible from the units it is intended to serve. N/A
Credit for indoor recreation facilities shall not exceed 25% of
the required community recreation area. N/A
Required community recreation areas shall not be located in
any required front yard and may not include any streets, drive-aisles, driveways, parking areas, storage areas, slopes of 5% or greater, or walkways (except those walkways that are clearly integral to the design of the recreation area).
N/A
Recreation Area Parking
In addition to required resident and visitor parking, recreation area parking shall be provided, as follows: 1
space for each 15 residential units, or fraction thereof, for units located more than 1,000 feet from a community recreation area.
N/A
The location of recreation area parking shall be subject to the same location requirements as for visitor parking, except that required recreation area parking shall not be located within a driveway(s).
N/A
Examples of recreation facilities include, but are not limited to, the following:
Active
Swimming pool area Children’s playground equipment Spa Courts (tennis, racquetball, volleyball, basketball)
Recreation rooms or buildings Horseshoe pits Pitch and putt Grassy play areas with a slope of less than 5% (minimum area of 5,000 square feet and a minimum dimension of 50 feet)
Any other facility deemed by the City Planner to satisfy the intent of providing active recreational facilities.
Passive
Benches Barbecues Community gardens Grassy play areas with a slope of less than 5%.
PLANNED DEVELOPMENTS (CMC SECTION 21.45.060)
TABLE C: GENERAL DEVELOPMENT STANDARDS
APPLICABLE TO ALL PLANNED DEVELOPMENTS
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
C.10 Lighting Lighting adequate for pedestrian and vehicular safety shall be provided.
The project is conditioned to complete a final landscape plan. Appropriate lighting for the two home project will be
evaluated with the final landscape plan. Project complies.
C.11 Reserved
C.12 Recreational Vehicle (RV) Storage (1)
Required for projects with 100 or more units, or a master or specific plan with 100 or more planned development units. Exception: RV storage is not required for projects located within the R-15 or R-23 land use designations.
N/A 20 square feet per unit, not to include area required for driveways and approaches. Developments located within master plans or residential specific plans may have this requirement met by the common RV storage area provided by the master plan or residential specific plan.
RV storage areas shall be designed to accommodate recreational vehicles of various sizes (i.e. motorhomes, campers, boats, personal watercraft, etc.). N/A
The storage of recreational vehicles shall be prohibited in the front yard setback and on any public or private streets or any other area visible to the public. A provision containing this restriction shall be included in the covenants, conditions
and restrictions for the project. All RV storage areas shall be screened from adjacent residences and public rights-of-way by a view-obscuring wall and landscaping.
N/A
C.13 Storage Space
480 cubic feet of separate storage space per unit. A storage unit at least 392 cubic feet is provided for each unit in the basement. Project complies. If all storage for each unit is located in one area, the space may be reduced to 392 cubic feet.
Required storage space shall be separately enclosed for each unit and be conveniently accessible to the outdoors. N/A
Required storage space may be designed as an enlargement of a covered parking structure provided it does not extend into the area of the required parking stall, and does not impede the ability to utilize the parking stall (for vehicle parking).
N/A
A garage (12’x20’ one-car, 20’x20’ two-car, or larger) satisfies the required storage space per unit. N/A
This requirement is in addition to closets and other indoor storage areas. N/A
(1) This standard does not apply to housing for senior citizens (see Chapter 21.84 of this code).
PLANNED DEVELOPMENTS (CMC SECTION 21.45.080)
TABLE E: CONDOMINIUM PROJECTS
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
E.1 Livable Neighborhood
Policy
Must comply with city council Policy 66, Principles for the Development of Livable Neighborhoods. SEE SEPARATE COMPLIANCE CHART
E.2 Architectural
Requirements
One-family and
two-family dwellings
Must comply with city council Policy 44, Neighborhood Architectural
Design Guidelines N/A
Multiple-family dwellings
There shall be at least three separate building planes on all building elevations. The minimum offset in planes shall be 18 inches and shall include, but not be limited to, building walls, windows, and roofs.
All building elevations provide at
least three separate building planes that include exterior walls, balconies and roofs. All building elevations shall incorporate a minimum of four complimentary design elements, including but not limited to:
A variety of roof planes;
Windows and doors recessed a minimum of 2 inches;
Decorative window or door frames;
Exposed roof rafter tails;
Dormers; Columns;
Arched elements;
Varied window shapes; Exterior wood elements;
Accent materials such as brick, stone, shingles, wood, or siding;
Knee braces; and Towers.
All building elevations incorporate a minimum of four complimentary design elements including exterior wood elements, varied window
shapes and accent materials including stone tile, plaster with acrylic finish and siding. Project complies.
E.3 Maximum Coverage 60% of total project net developable acreage. Proposed building coverage is 60% of the net lot area (0.15 acres). Project complies.
E.4
Maximum
Building Height
Same as required by the underlying zone, and not to exceed three stories (1)(7)
The project is located within the BAOZ, and therefore pursuant to Footnote #1 below, building height shall be subject to the requirements
of C.M.C. Chapter 21.82. Pursuant to C.M.C. Section 21.82.050, no residential structure shall exceed 30 ft. when providing a minimum 3:12
roof pitch, or 24 ft. when providing less than a 3:12 roof pitch. The project is proposing a building height of 30 ft. with a 3:12 roof pitch. Roof decks are less than or equal to
24 ft. in height. Project complies.
Projects
within the R-23 general plan designation (1)(7)
40 feet, if roof pitch is 3:12 or greater N/A. Project is located within the
BAOZ. Therefore, pursuant to Footnote #1 below, building height shall be subject to the requirements of C.M.C. Chapter 21.82. As discussed above, project complies.
35 feet, if roof pitch is less than 3:12
Building height shall not exceed three stories
PLANNED DEVELOPMENTS (CMC SECTION 21.45.080)
TABLE E: CONDOMINIUM PROJECTS
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
E.5
Minimum
Building Setbacks
From a
private or public street(2)(3)
Residential structure 10 feet
Garfield Street is a public street. The residential structure is setback
10 ft. as measured from the outside edge of the required street right-of-way width. The project proposes 10 ft. from Garfield Street. Project complies.
Direct entry garage 20 feet N/A
From a drive-aisle(4)
Residential structure (except
as specified below)
5 feet, fully landscaped (walkways providing access to dwelling entryways may be located within required
landscaped area)
N/A. Project is less than 25 units and located within the R-23 General
Plan designation (see section below for compliance).
Residential
structure –directly above a garage
0 feet when projecting over the front of a garage.
N/A. Project is less than 25 units
and located within the R-23 General Plan designation (see section below for compliance).
Garage
3 feet N/A. Project is less than 25 units and located within the R-23 General Plan designation (see section below
for compliance).
Garages facing directly onto a drive-aisle shall be equipped with an automatic garage door opener.
Projects of 25 units or less within the R-15
and R-23 general plan designations
0 feet (residential structure and garage) N/A
Garages facing directly onto a drive-aisle shall be equipped with an automatic garage door opener. N/A
Balconies/decks (unenclosed and
uncovered)
0 feet
N/A.
May cantilever over a drive-aisle, provided the balcony/deck complies with all other applicable requirements, such as: Setbacks from property lines
Building separation
Fire and Engineering Department requirements
From the perimeter property lines of the project site (not adjacent to a public/private street)
The building setback from an interior side or rear perimeter property line shall be the same as required by the underlying zone for an interior side or rear yard setback.
The underlying zone for the project is R-3. The required interior side yard setback for R-3 is 10% of the lot width or 5 ft. for this property.
The project has an interior side yard setback of 5”. The required rear yard setback for R-3 is double the interior side yard or 10 ft. for this
property. The project provides a rear yard setback of 10-15 ft along the east side. Project complies.
E.6 Minimum Building Separation 10 feet N/A
PLANNED DEVELOPMENTS (CMC SECTION 21.45.080)
TABLE E: CONDOMINIUM PROJECTS
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
E.7 Resident
Parking (6)
All dwelling types
If a project is located within the R-23 general plan designation, resident parking shall be provided as specified below, and may also
be provided as follows:
25% of the units in the project may include a tandem two-car garage (minimum 12 feet x 40 feet).
Calculations for this provision resulting in a fractional unit may be rounded up to the next whole number.
N/A
One-family and two-
family dwellings
2 spaces per unit, provided as either:
a two-car garage (minimum 20 feet x 20 feet), or
2 separate one-car garages (minimum 12 feet x 20 feet each) In the R-W Zone, the 2 required parking spaces may be provided as 1 covered space and 1 uncovered space (5)
N/A
Multiple-family dwellings
Studio and one-bedroom units
1.5 spaces per unit, 1 of which must be covered (5)
N/A When calculating the required number of parking spaces, if the calculation results in a fractional parking space, the required number of parking spaces shall always be rounded up to the nearest whole number.
Units with two or more bedrooms
2 spaces per unit, provided as either:
a one-car garage (12 feet x 20 feet) and 1 covered or uncovered space; or (5)
a two-car garage (minimum 20 feet x 20 feet), or
2 separate one-car garages (minimum 12 feet x 20 feet each)
In the R-W Zone and the Beach Area Overlay Zone, the 2 required parking spaces may be provided as 1 covered space and 1 uncovered
space (5)
Two parking spaces are provided per unit in a basement parking garage. Project complies.
Required parking may be provided within an enclosed parking garage
with multiple, open parking spaces, subject to the following:
Each parking space shall maintain a standard stall size of 8.5 feet
by 20 feet, exclusive of supporting columns; and
A backup distance of 24 feet shall be maintained in addition to a minimum 5 feet turning bump-out located at the end of any stall
series.
All parking in the basement parking garage has a minimum 8.5 ft. by 20
ft. dimension exclusive of supporting columns. Project complies.
Required resident parking spaces shall be located no more than 150
feet as measured in a logical walking path from the entrance of the units it could be considered to serve. N/A
PLANNED DEVELOPMENTS (CMC SECTION 21.45.080)
TABLE E: CONDOMINIUM PROJECTS
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
E.8
Private Recreational
Space
One-family, two-family, and
multiple-family dwellings
Required private recreational space shall be designed so as to be functional, usable, and easily accessible from the dwelling it is
intended to serve.
N/A Required private recreational space shall be located adjacent to the
unit the area is intended to serve.
Required private recreational space shall not be located within any
required front yard setback area, and may not include any driveways, parking areas, storage areas, or common walkways.
One-family and two-family dwellings
Minimum total area per unit
Projects not within the R-15 or R-
23 general plan designations 400 square feet
N/A Projects within the R-15 or R-23 general plan designations 200 square feet
May consist of more than one recreational space. N/A
May be provided at ground level and/or as a deck/balcony on a second/third floor or roof. N/A
If provided at ground level
Minimum dimension
Not within the R-15 or R-23 general plan designations 15 feet N/A Within the R-15 or R-23 general plan designations 10 feet
Shall not have a slope gradient greater than 5%. N/A
Attached solid patio covers and decks/balconies may project into a required private recreational
space, subject to the following:
The depth of the projection shall not exceed 6 feet (measured from the wall of the dwelling that
is contiguous to the patio/deck/balcony).
The length of the projection shall not be limited, except as required by any setback or lot coverage standards.
N/A
Open or lattice-top patio covers may be located within the required private recreation space
(provided the patio cover complies with all applicable standards, including the required setbacks).
N/A
If provided above ground level as a deck/ balcony or roof deck
Minimum dimension 6 feet N/A
Minimum area 60 square feet
Multiple-family dwellings
Minimum total area per unit (patio, porch, or balcony) 60 square feet Each unit has a porch, balcony and/or exclusive use roof deck area
at least 60 square feet with a minimum dimension of 6 ft. Project complies. Minimum dimension of patio, porch or balcony 6 feet
Projects of 11 or more units that are within the R-23 general plan designation may opt to provide an additional 75 square feet of community recreation space per unit (subject to the standards specified in Table C of this Chapter), in lieu of providing the per unit
private recreational space specified above.
N/A
(1) If a project is located within the Beach Area Overlay Zone, building height shall be subject to the requirements of Chapter 21.82 of this code.
(2) See Table C in Section 21.45.060 for required setbacks from an arterial street. (3) Building setbacks shall be measured from the outside edge of the required street right-of-way width, whichever is closest to the building. (4) Building setbacks shall be measured from one of the following (whichever is closest to the building): a) the outside edge of the required drive-aisle width; b) the back of sidewalk; or c) the nearest side of a parking bay located contiguous to a drive-aisle (excluding parking located
in a driveway in front of a unit’s garage). (5) Any uncovered required parking space in the R-W zone may be located within a required front yard setback and may be tandem. (6) This standard does not apply to housing for senior citizens (see Chapter 21.84 of this code). (7) Protrusions above the height limit shall be allowed pursuant to Section 21.46.020 of this code. Such protrusions include protective barriers for balconies and roof decks.
ATTACHMENT NO. 5
CITY COUNCIL POLICY 66 – LIVABLE NEIGHBORHOODS
Principle Compliance Comments
1 Building Facades, Front Entries, Porches
Facades create interest and character and should be varied
and articulated to provide visual interest to pedestrians.
Clearly identifiable front doors and porches enhance the
street scene and create opportunities for greater social
interaction within the neighborhood. Building entries and
windows should face the street. Front porches, bay
windows, courtyards and balconies are encouraged.
The west elevation architecture
facing Garfield Street provides
multiple material finishes, varied
window shapes, articulated building
planes and a patio/balcony.
Although the front entries are
located along the side, a clear
pedestrian pathway to the entry is
located from Garfield Street.
Project complies.
2 Garages
Homes should be designed to feature the residence as the
prominent part of the structure in relation to the street. A
variety of garage configurations should be used to improve
the street scene. This may include tandem garages, side-
loaded garages, front-loaded garages, alley-loaded garages
and recessed garages.
The three-unit residential
condominium building is the
prominent feature along Garfield
Street. All parking is located in a
basement level and not visible
from the street. Project complies.
3 Street Design
An interconnected, modified (grid) street pattern should be
incorporated into project designs when there are no
topographic or environmental constraints. Interconnected
streets provide pedestrians and automobiles many
alternative routes to follow, disperse traffic and reduce the
volume of cars on any one street in the neighborhood. Streets
should be designed to provide both vehicular and pedestrian
connectivity by minimizing the use of cul-de-sacs.
The street network should also be designed to create a
safer, more comfortable pedestrian and bicycling
environment. Local residential streets should have travel
and parking lanes, be sufficiently narrow to slow traffic,
provide adequate access for emergency and service vehicles
and emergency evacuation routes for residents and include
parkways with trees to form a pleasing canopy over the
street. Local residential streets are the public open space in
which children often play and around which neighborhoods
interact. Within this context, vehicular movement should be
additionally influenced through the use of City-accepted
designs for traffic calming measures.
The project is developing on an
existing multi-family residentially
zoned lot adjacent to an existing
public street (Garfield Street)
presently developed as part of an
existing interconnected modified
street pattern in the Beach Area
Overlay Zone. The existing street
design in this area, where already
improved, provides curb adjacent
parkways and sidewalks on Garfield
Street. A street tree will be
maintained or installed for the
project. Project complies.
CITY COUNCIL POLICY 66 – LIVABLE NEIGHBORHOODS (CONTINUED)
Principle Compliance Comments
4 Parkways
Street trees should be planted in the parkways along all
streets. Tree species should be selected to create a unified
image for the street, provide an effective canopy, avoid
sidewalk damage and minimize water consumption.
See Section 3 above.
5 Pedestrian Walkways
Pedestrian walkways should be located along or visible from
all streets. Walkways (sidewalks or trails) should provide
clear, comfortable and direct access to neighborhood
schools, parks/plazas and transit stops. Primary pedestrian
routes should be bordered by residential fronts, parks or
plazas. Where street connections are not feasible (at the
end of cul-de-sacs), pedestrian paths should also be
provided.
The project provides for pedestrian
circulation in the form of existing
sidewalks along its frontage with
Garfield Street. An existing
sidewalk is located on both sides of
the street. Project complies.
6 Centralized Community Recreation Areas
Park or plazas, which serve as neighborhood meeting places
and as recreational activity centers should be incorporated
into all planned unit developments. As frequently as
possible, these parks/plazas should be designed for both
active and passive uses for residents of all ages and should
be centrally located within the project. Parks and plazas
should be not be sited on residual parcels, used as buffers
from surrounding developments or to separate buildings
from streets.
The project consists of only three
dwellings and is not required to
provide community recreation
areas. Project complies.