HomeMy WebLinkAbout2015-04-15; Planning Commission; ; CT 13-04|PUD 13-10|CDP 13-33 - GOLDEN SURF
The City of Carlsbad Planning Division
A REPORT TO THE PLANNING COMMISSION
Item No.
Application complete date: October 14, 2014
P.C. AGENDA OF: April 15, 2015 Project Planner: Jason Goff
Project Engineer: Steve Bobbett
SUBJECT: CT 13-04/PUD 13-10/CDP 13-33 – GOLDEN SURF – Request for approval of a Tentative
Tract Map, Planned Development Permit and Coastal Development Permit to allow for
1) the subdivision, grading and development of a 1.08 acre parcel currently developed
with an existing single-family home and second dwelling unit into three (3) lots and four
(4) airspace condominium units; and 2) construction of four (4) detached two-story
single-family condominium units (ranging from 2,213 square feet to 2,256 square feet)
with exclusive use areas and a common drive on proposed Lot 1; a 3,250 square foot
two-story single-family home on proposed Lot 2; and an existing single-family home
with second dwelling unit to remain on proposed Lot 3 on property located at 6798
Paseo Del Norte within the Zone 20 Specific Plan (SP 203), Mello II Segment of the Local
Coastal Program, and Local Facilities Management Plan 20. The project qualifies as a
CEQA Guidelines Section 15332 (In-Fill Development Projects) Class 32 Categorical
Exemption. This project is not located within the appealable area of the California
Coastal Commission.
I. RECOMMENDATION
That the Planning Commission ADOPT Planning Commission Resolution No. 7095 APPROVING Tentative
Tract Map (CT 13-04), Planned Development Permit (PUD 13-10), and Coastal Development Permit (CDP
13-33), based on the findings and subject to the conditions contained therein.
II. PROJECT DESCRIPTION AND BACKGROUND
The 1.08-acre infill site is located on the northeast corner of the intersection of Paseo Del Norte and
Camino De Las Ondas as shown on the attached location map (see Attachment No. 2). Primary access to
project site is off of Camino de Las Ondas, which is a fully improved street complete with curb, gutter
and sidewalk. The project site is presently developed with an existing one-story single-family home
(1,800 sq. ft.) and an attached second dwelling unit (638 sq. ft.) situated over a three-car garage. A
small orchard of various fruit trees exists on the property to the east and northeast of the existing
residence. Topographically, the site is located upon a gently to moderately inclined slope descending in
the northeasterly direction. The highest elevation of the property is at 175 feet above mean sea level
(AMSL) in the area of the existing residence. The lowest elevation of the property is in the northeast
corner at 158.5 ft. AMSL. The site is considered extensively disturbed, with onsite vegetation consisting
of non-native grassland, orchard, and developed/non-native vegetation. No native or wetland habitats
or natural drainage areas exist on the property or within the vicinity. An existing 6-foot tall solid
masonry wall covered with a dense green screen of vines separates the subject property from a single-
family neighborhood (“The Cove”) along the north and east property lines. Four (4) detached single-
family homes and Lands End Court adjoin the subject property along these two boundaries. Along a
portion of the north and west property lines, a 6-foot tall chain-link fence separates the subject property
from a row of five (5) two-story multi-family residential condominium units, which are part of the Alta
Mira residential condominium project.
3
CT 13-04/PUD 13-10/CDP 13-33 – GOLDEN SURF
April 15, 2015
Page 2
The project is proposing to subdivide the 1.08-acre infill site into three (3) separate lots and four (4)
airspace condominium units. Development of the site includes construction of four (4) detached two-
story single-family condominium units with exclusive use areas and a common drive on proposed Lot 1
(0.61 acres), and a 3,250 square foot two-story single-family home on proposed Lot 2 (0.16 acres). The
existing residence and second dwelling unit are proposed to remain on the newly proposed Lot 3 (0.31
acres).
The four airspace condominium units (Units 1-4) proposed on Lot 2 are plotted in a detached single-
family configuration with exclusive use areas. Each two-story home includes an attached two-car garage
and driveway accessed from a common motor court and driveway enhanced with pervious pavers in a
decorative pattern. Two (2) floor plans and two (2) different elevation styles (Plans A and B) are
proposed with design detailing and materials consistent with the Spanish and Santa Barbara
architectural styles. For variation, the Unit 3/Plan B offers an alternate elevation that includes a
stone veneer on a portion of the front elevation. Plans A and B each include four-bedrooms and
range in size from 2,213 square feet to 2,256 square feet. Plan A is 25’-6” in height, while Plan B is 25’-
7.” Except for the exclusive use area associated with each unit, the underlying lot will be held in
common interest divided between the four airspace single-family condominiums. The common area
primarily includes, but is not limited to, the private driveway and motor court, guest parking area,
retaining walls, fencing, landscaping, lighting and sidewalk. Primary building materials for all homes
consist of a stucco finish with foam accent trim and detailing; and concrete roof tiles over a 4:12 pitched
roof.
The detached single-family home proposed on Lot 2 is 3,250 sq. ft. in size and includes four (4)
bedrooms and an attached 2-car garage. The two-story home ranges in height from 25’-7” to 27’-11.”
The front elevation facing Camino de Las Ondas includes a double entry front door behind a large
covered porch; and a second floor balcony (174 sq. ft.) off of the master bedroom that will offer up
views of the ocean to the west. Primary building materials consist of a stucco finish with foam accent
trim and detailing; and concrete roof tiles over a 4:12 pitched roof.
Table A below includes the General Plan designations, zoning and current land uses of the project site
and surrounding properties.
TABLE A
Location General Plan Designation Zoning Current Land Use
Site
Residential Medium Density
(RM, 4-8 du/ac,
GMCP of 6 du/ac)
Planned Community
(P-C)
Single-family home w/ second
dwelling unit
North RM P-C Detached single-family and multi-
family condominiums
South RM P-C Multi-family condominiums
East RM P-C Detached single-family
West RM P-C Multi-family condominiums
CT 13-04/PUD 13-10/CDP 13-33 – GOLDEN SURF
April 15, 2015
Page 3
Table B below includes 1) the project site’s gross and net acreage; 2) the number of dwelling units
allowed by the General Plan’s Growth Management Control Point (GMCP) density; and 3) the number of
proposed dwelling units and overall project density.
TABLE B
Gross Acres Net Acres DUs Allowed
at GMCP Density DUs Proposed and Project Density
1.08 acres 1.08 acres 6.48 dwelling units
Five (5) single-family units are proposed, in addition
to the one (1) existing single-family home and
second dwelling unit for a total of 5.55 du/ac.*
*Second dwelling units are not counted towards overall project density pursuant to C.M.C. Section 21.10.030.E.
Project grading will require approximately 100 cubic yards (CY) of cut and 3,800 CY of fill. Fill is
proposed in the area of Lots 1 and 2 to create buildable pads, to achieve positive drainage towards
existing utilities in Camino de Las Ondas and to meet the existing sewer invert elevation serving the
property. To accommodate the proposed fill, retaining walls ranging from a 0.5 ft. up to 4 ft. in height
are proposed along the north and east property lines of proposed Lot 1; as well as the north and east
property lines of proposed Lot 2. Retaining walls, supporting between 1 ft. and 4 ft. of cut are proposed
along the west property line of Lot 1 and the north property line of proposed Lot 3.
In order to meet the City’s Inclusionary Housing requirements, the project is conditioned to pay an
affordable housing in-lieu fee on a per unit basis prior to final map approval.
A Tentative Tract Map (CT) is required to subdivide the property into three (3) lots and four (4) airspace
condominium units. A Planned Development Permit (PUD) is required pursuant to Section 21.38.150 of
the Carlsbad Municipal Code (C.M.C.) where a property is zoned P-C, is less than 100 acres in size, and
no Master Plan has been approved establishing underlying zoning or development standards. A Coastal
Development Permit (CDP), subject to the requirements of the Mello II Segment of the Local Coastal
Program, is required because the project site is located within the Coastal Zone.
III. ANALYSIS
The project is subject to the following plans, ordinances and standards:
A. Residential Medium Density (RM) General Plan Land Use designation;
B. Zone 20 Specific Plan (SP 203); Planned Community (P-C) Zone (C.M.C. Chapter 21.38) and
Planned Development Regulations (C.M.C. Chapter 21.45);
C. Mello II Segment of the Local Coastal Program, and the Coastal Resources Protection Overlay
Zone (C.M.C. Chapter 21.203);
D. Habitat Preservation and Management Requirements (C.M.C. Chapter 21.210)
E. Inclusionary Housing (C.M.C. Chapter 21.85);
F. Subdivision Ordinance (C.M.C. Title 20); and
G. Growth Management Ordinance (C.M.C. Chapter 21.90) and Zone 20 Local Facilities
Management Plan.
The recommendation for approval of this project was developed by analyzing the project’s consistency
with the applicable regulations and policies. The project’s compliance with each of the above
regulations is discussed in the sections below.
CT 13-04/PUD 13-10/CDP 13-33 – GOLDEN SURF
April 15, 2015
Page 4
A. General Plan
The General Plan Land Use designation for the project site is Residential Medium Density (RM). The RM
designation allows for medium density residential development at 4 to 8 du/ac with a GMCP of 6 du/ac;
which is used also for the purposes of calculating the city’s compliance with Government Code §65584.
The project site has a net developable acreage of 1.08 acres allowing for 6.48 dwelling units to be
developed at the GMCP. A total of 6 dwelling units with an overall density of 5.55 du/ac can be
accommodated, which is 0.48 units below the GMCP. Pursuant to Government Code §65863, the City
may not reduce the residential density on any parcel below that which was used by the California
Department of Housing and Community Development in determining compliance with Housing Element
law, unless the City makes findings that the reduction of residential density is consistent with the
adopted General Plan, including the Housing Element; and that the remaining sites identified in the
Housing Element are adequate to accommodate the city’s share of the regional housing need pursuant
to Government Code §65584.
The project is consistent with the City’s General Plan since the proposed density of 5.55 du/ac is within
the RM density range of 4 to 8 du/ac as specified for the site. The project’s proposed density of 5.55
du/ac is slightly below the GMCP density (6 du/ac) used for the purposes of calculating the city’s
compliance with Government Code §65584. However, consistent with Program 3.2 of the city’s
Certified Housing Element, all of the dwelling units which were anticipated toward achieving the city’s
share of the regional housing need that are not utilized by developers in approved projects are
deposited into the City’s Excess Dwelling Unit Bank. These excess dwelling units are available for
allocation to other projects. Accordingly, there is no net loss of residential unit capacity and there are
adequate properties identified in the Housing Element allowing residential development with a unit
capacity adequate to satisfy the city’s share of the regional housing need. Accordingly, 0.48 dwelling
units will be deposited into the city’s excess dwelling unit bank.
In addition to the above, the project also complies with the Elements of the General Plan as outlined in
Table C below:
TABLE C - GENERAL PLAN COMPLIANCE
ELEMENT USE, CLASSIFICATION, GOAL,
OBJECTIVE OR PROGRAM
PROPOSED USES &
IMPROVEMENTS COMPLIANCE
Land Use The site is designated for
Residential Medium (RM) density
(4-8 du/ac, with a GMCP of 6
du/ac).
6 dwellings units could be
constructed on the site at the
GMCP.
Five (5) single-family
dwelling units being
proposed, plus one (1)
existing single-family
dwelling unit for a total of
six (6) single-family
dwelling units.
The project’s density of
5.55 du/ac is within the RM
density range of 4-8 du/ac.
The project will deposit
0.48 dwelling units into the
City’s Excess Dwelling Unit
Bank.
Yes
CT 13-04/PUD 13-10/CDP 13-33 – GOLDEN SURF
April 15, 2015
Page 5
TABLE C - GENERAL PLAN COMPLIANCE (CONTINUED)
ELEMENT USE, CLASSIFICATION, GOAL,
OBJECTIVE OR PROGRAM
PROPOSED USES &
IMPROVEMENTS COMPLIANCE
Housing Provision of affordable housing. The project is conditioned
to pay an affordable
housing in-lieu fee on a per
unit basis (5 units total)
prior to final map.
Yes
Public Safety Reduce fire hazards to an
acceptable level
The project site is located
within a five minute
response time of Fire
Station No. 4 and has been
designed to comply with
the fire code, including
provisions for an automatic
sprinkler system within
each dwelling unit.
Yes
Open Space &
Conservation
Minimize the environmental
impacts to sensitive resources
within the City.
Utilize Best Management Practices
for control of storm water and to
protect water quality.
The project will not have
any environmental impacts
on the previously graded
and developed site that is
void of sensitive habitat.
The project is conditioned
to conform to all NPDES
requirements and has been
designed to include Low
Impact Design (LID)
elements.
Yes
Yes
Noise Comply with the residential
exterior noise standard of 60 dB(A)
CNEL and interior noise standard of
45 dB(A) CNEL.
Per a site specific Noise
Study prepared by ABC
Acoustics, Inc., dated July
21, 2014, the project will
comply with the exterior
noise standard of 60 dB(A)
and interior noise standard
of 45 dB(A) CNEL with no
mitigation required.
Yes
Circulation Construct roadway improvements
needed to serve proposed
development.
Curb, gutter and sidewalk
presently exist along
Camino de Las Ondas. No
new public roadway
improvements are
necessary except for two
curb cuts for connecting
project driveways at Lot 1
and 2.
Yes
CT 13-04/PUD 13-10/CDP 13-33 – GOLDEN SURF
April 15, 2015
Page 6
B. Zone 20 Specific Plan (SP 203) and Planned Development Regulations (Chapter 21.45 of the
Carlsbad Municipal Code)
The subject property is located within Planning Area B of the Zone 20 Specific Plan (SP 203). According
to SP 203, several properties within Planning Area B were zoned Planned Community (P-C) in the 1970’s;
where at the time, it was envisioned that a master plan would later be prepared. A master plan was not
prepared in the case of the existing developed property. It is important to note that the P-C zone in and
by itself does not establish any development standards, but instead relies on the preparation of a
master plan to establish development standards. Where no master plan is approved, C.M.C. Section
21.38.150 states that parcels zoned P-C with an area of less than 100 acres shall be developed pursuant
to the Planned Development Regulations (C.M.C. Chapter 21.45). The project includes a Planned
Development Permit (PUD 13-10) and is compliant with all applicable requirements and development
standards of the Planned Development Regulations as demonstrated in Staff Report Attachments No. 4-
6. Project compliance with all applicable requirements of City Council Policies No. 44 and 66, made
pursuant to Planned Development Table D and E are also demonstrated in Staff Report Attachments No.
7-8.
C. Conformance with the Coastal Development Regulations for the Mello II Segment of the Local
Coastal Program (CMC Chapter 21.201) and the Coastal Resources Protection Overlay Zone (CMC
Chapter 21.203).
The project site is located within the Mello II Segment of the Local Coastal Program, but is not within the
appealable jurisdiction of the California Coastal Commission. The site is also located within and subject
to the Coastal Resources Protection Overlay Zone. The project’s compliance with each of these
programs and ordinances is discussed below:
1. Mello II Segment of the Certified Local Coastal Program and all applicable policies.
The project is located in the Mello II Segment of the Local Coastal Program. The project site has a Local
Coastal Program Land Use designation of Residential Medium Density (RM) and is zoned Planned
Community (P-C) consistent with the City’s General Plan Land Use designation and Zoning for the site.
The RM Land Use designation allows development of single-family residences at a density of 4-8
dwelling units per acre with a Growth Management Control Point (GMCP) of 6 dwelling units per acre.
At the RM GMCP, 6.48 dwelling units would be permitted on this 1.08 acre (net developable) property.
One of the primary requirements of the applicable coastal regulations pertains to the conversion of
agricultural land to urban use. The project site is not identified as a “Map X - Designated Coastal
Agricultural Lands” and therefore, is not required to be preserved nor is it subject to an agricultural
conversion mitigation fee. The project is further consistent with the policies of the Coastal Act in that, a)
the site is geologically stable; b) the project has been designed to reduce the amount of runoff off-site
through the use of Low Impact Development (LID) design features and has been conditioned to
implement the National Pollution Discharge Elimination System (NPDES) standards; c) the project does
not preclude any recreational opportunities or shoreline access as the property is not located adjacent
to any waterways or bodies of water; and d) the development does not obstruct views of the coastline
as seen from public lands or public rights-of-way.
2. Coastal Resource Protection Overlay Zone
The project is consistent with the provisions of the Coastal Resource Protection Overlay Zone (C.M.C.
Chapter 21.203) in that the project will adhere to the City’s Master Drainage Plan, Grading Ordinance,
Storm Water Ordinance, Standard Urban Storm Water Mitigation Plan (SUSMP) and Jurisdictional Urban
CT 13-04/PUD 13-10/CDP 13-33 – GOLDEN SURF
April 15, 2015
Page 7
Runoff Management Program (JURMP) to avoid increased urban run-off, pollutants and soil erosion. No
development is proposed in areas of natural steep slopes (≥25% gradient) and no native vegetation is
located on the subject property. In addition, the site is not located in an area prone to landslides, or
susceptible to accelerated erosion, floods or liquefaction.
D. Habitat Preservation and Management
The City of Carlsbad’s Habitat Management Plan (HMP) identifies the 1.08-acre project site as a
“Development Area” and is not located adjacent to or near any Standards Area or Existing/Proposed
Hardline Preserve Areas. A biological investigation of the project site was prepared in accordance with
the HMP. The site was identified as being extensively disturbed, supporting 0.44-acres of Annual (non-
native) Grassland (HMP Group-E Habitat), 0.27-acres of Orchard (HMP Group-F Habitat), and 0.37-acres
of Developed/Non-native Vegetation. No native or wetland habitats or natural drainage areas were
observed on the project site or within the vicinity. Impacts to HMP Group-E Habitat are required to be
mitigated at 0.5:1. Therefore, the impacts to 0.44-acres of Annual (non-native) Grassland will require
0.22-acres of mitigation. HMP Group-E and Group-F habitats can be mitigated through payment of an
in-lieu fee on a per acre basis. Pursuant to the HMP, the project has been conditioned to pay habitat in-
lieu fees for impacts to 0.22-acres of Group-E habitat and 0.27-acres of Group-F habitat. No mitigation
is required for impacts to the areas consisting of existing developed or non-native vegetation.
E. Inclusionary Housing
For all residential development of less than seven (7) units, the inclusionary housing requirement may
be satisfied through the payment of an inclusionary housing in-lieu fee. The proposal to construct four
(4) detached single-family condominium units with exclusive use areas on Lot 1 and one (1) single-family
home on Lot 2 has been conditioned to pay the applicable housing in-lieu fees for a total of five (5) units
prior to final map approval.
F. Subdivision Ordinance
The project includes three (3) lots, one of which will include four (4) airspace condominium units and is
therefore subject to the regulations of Chapter 20.16 of the Subdivision Ordinance. These subdivision
regulations require the project to include required street dedications and improvements (streets, sewer,
water, and drainage) to serve the proposed subdivision.
The Land Development Engineering Division has reviewed the proposed Tentative Tract Map and has
concluded that the subdivision, as conditioned, complies with all applicable requirements of the
Subdivision Map Act and the City’s Subdivision Ordinance. The project fronts on Camino de Las Ondas,
which is a fully improved street, complete with curb, gutter and sidewalk. No additional frontage
improvements will be required at this time other than two (2) curb cuts for vehicular access and a
drainage connection. General utility and access easements will be dedicated on the final map to allow
for the construction of project drainage, sewer, and water facilities.
No standards variances are needed to approve the project. Given the above, the proposed subdivision
would provide all necessary facilities and improvements without producing land conflicts; therefore, the
project is consistent with the Subdivision Ordinance.
CT 13-04/PUD 13-10/CDP 13-33 – GOLDEN SURF
April 15, 2015
Page 8
G. Growth Management Ordinance
The proposed project is located within Local Facilities Management Zone 20 in the southwest quadrant
of the City. The impacts on public facilities created by the project, and its compliance with the adopted
performance standards, are summarized in Table “E” below.
TABLE E – GROWTH MANAGEMENT COMPLIANCE
STANDARD IMPACTS COMPLIANCE
City Administration 17.38 sq. ft. Yes
Library 9.27 sq. ft. Yes
Waste Water Treatment 5 EDU Yes
Parks 0.03 acre Yes
Drainage 2 CFS / Drainage Basin “C/D” Yes
Circulation 50 ADT Yes
Fire Station No. 4 Yes
Open Space 0 acres NA
Schools Carlsbad (E= 1.7/ M= 0.592/ HS = 0.516) Yes
Sewer Collection System 5 EDU Yes
Water 2,750 GPD Yes
The unit yield of the property at the RM GMCP (6 du/ac) is 6.48 dwelling units and 6 units are proposed
(5 proposed, plus 1 existing). The proposed project is 0.48 units below the GMCP for RM properties.
These units will be deposited in the City’s Excess Dwelling Unit Bank.
IV. ENVIRONMENTAL REVIEW
The City Planner has determined that the project belongs to a class of projects that the State Secretary
for Resources has found do not have a significant impact on the environment, and it is therefore
categorically exempt from the requirement for the preparation of environmental documents pursuant
to Section 15332 (In-Fill Development Projects) Class 32 Categorical Exemption of the State CEQA
Guidelines. The project is consistent with the General Plan and the Zoning Ordinance; the project site is
within the City limits, is less than 5 acres in size, and is surrounded by urban uses; there is no evidence
that the site has value as habitat for endangered, rare, or threatened species; approval of the project
will not result in significant effects relating to traffic, noise, air quality, or water quality; and the site can
be adequately served by all required utilities and public services. In making this determination, the City
Planner has found that the exceptions listed in Section 15300.2 of the state CEQA Guidelines do not
apply to this project. A Notice of Exemption will be filed by the City Planner upon final project approval.
ATTACHMENTS:
1. Planning Commission Resolution No. 7095
2. Location Map
3. Disclosure Statement
4. Planned Development Compliance Table C
5. Planned Development Compliance Table D
6. Planned Development Compliance Table E
7. City Council Policy 44 Compliance Table
8. City Council Policy 66 Compliance Table
9. Reduced Exhibits
10. Full Size Exhibits “A – Y” dated April 15, 2015
CAMINO DE LAS ONDASPASEO DEL NORTEMONTIA CTRUSSELIACTE L D E R C T
NEPETA WYHEATHCTLIGHTHOUSE RD
SEASCAPE DRSHE
A
R
WA
T
E
RDRLANDS END CT
SEAHORSE CT
MELALEUCA AVWHITESAIL STWATERCOUR
S
E
D
RZI
N
N
I
A
C
T
FUCHSIA LN
CT 13-04 / PUD 13-10 / CDP 13-33Golden Surf
SITE MAP
J
SITE
EL
CAMINO
R
E
A
LLA COSTA AV
A L G A R D
C
A
R
L
S
B
A
D
B
L
«~» ~ CITY OF
DISCLOSURE
STATEMENT
P-1(A)
Development Services Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.gov CARLSBAD
Applicant's statement or disclosure of certain ownership interests on all applications which will
require discretionary action on the part of the City Council or any appointed Board, Commission
or Committee.
The following information MUST be disclosed at the time of application submittal. Your project
cannot be reviewed until this information is completed. Please print.
~~~t~~\~'"a~~~"~~!~~,:;~~~~-in~i~r~u{~~triil~C~~R~&H~r,~~J~;J§r~t';¥~~~u~i,l~~~~qi~t~~n. ~sf~~~t~~~~~J~~f~~~~~ .()<fl<l,ni;z;~!i.9q1~?m9r~.ti.'l!J·'·e~t"\t'i?~~t!!~t1r!l,c.~iy§~' ~YI)1Ji~afe,;)fl.W!s.?~lJ1.~r'JY:;~to~r{¢9ynty,,pity ~nd'~9.~rity,• city·ygni~;g~li~,;.B;1lf)~r~~gt~~~~~~i~i~:~!,~;~~lvisi~g~rrjy~'~!~.j;'~f~}~'(~·~o~p[~~tigp:~~in~"\s;;;nit~ •..• A9~r1t~?m~~.~sfJrff~;l;,,~~~uJ~~t~JKt~~.~~r:;:i~e.•IE)~~~··t1a~~l~h9·~~\\t~~tf~~iapRI~6a~t a,n<J;;r~P.~~.o~il~r rrius(ge f.lr(l'JiclticJU2E;lli:lw.. . ) ''''i'" · · ··; ~\.\• .. .. . ..
1. APPLICANT (Not the applicant's agent)
Provide the COMPLETE. LEGAL names and addresses of ALL persons having a
financial interest in the application. If the applicant includes a corporation or partnership,
include the names, titles, addresses of all individuals owning more than 10% of the
shares. IF NO INDIVIDUALS OWN MORE THAN 10% OF THE SHARES, PLEASE
INDICATE NON-APPLICABLE (N/A) IN THE SPACE BELOW. If a publicly-owned
corporation, include the names, titles, and addresses of the corporate officers. (A
separate)38ge may be attached if necessary.)
Person fS___~ j2~,.J Corp/Part __________ _
Title ~ ~ C/fA.);JertL. Title--=~--.,.-=--.,..-,------
Address£0, t-11')1 f;Jo, ~~ f:i!Jre~'Z-o/8-0.t:JIO
I
2. OWNER (Not the owner's agent)
P·1(A)
Provide the COMPLETE. LEGAL names and addresses of ALL persons having any
ownership interest in the property involved. Also, provide the nature of the legal
ownership (i.e., partnership, tenants in common, non-profit, corporation, etc.). If the
ownership includes a corporation or partnership, include the names, titles, addresses of
all individuals owning more than 10% of the shares. IF NO INDIVIDUALS OWN MORE
THAN 10% OF THE SHARES, PLEASE INDICATE NON-APPLICABLE (N/A) IN THE
SPACE BELOW. If a publicly-owned corporation, include the names, titles, and
addresses of the corporate officers. (A separate page may be attached if necessa~.)
·· rr~
Person br'-""""' \4e.,k VJAoV.Vej Corp/Part ___________ _
Title f('U)th ~ f--Title ___________ _
Address (.., 'l-~ K Pc..~ \\e.,\ 10~.£:Jd7ess ________ _
~b ~c). C/1 77JJ] 1
'
Page 1 of 2 Revised 07/10
ATTACHMENT 4
PLANNED DEVELOPMENTS (CMC SECTION 21.45.060)
TABLE C: GENERAL DEVELOPMENT STANDARDS
(APPLIES TO LOTS 1 AND 2)
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
C.1 Density
Per the underlying General Plan designation. When two or more general plan land use
designations exist within a planned development, the density may be transferred from
one general plan designation to another with a general plan amendment.
NA.
C.2 Arterial
Setbacks
All dwelling units adjacent to any arterial road shown on the Circulation Element of the
General Plan shall maintain the following minimum setbacks from the right-of-way:
Prime Arterial 50 Feet
Major Arterial 40 Feet
Secondary Arterial 30 Feet
Carlsbad Boulevard 20 Feet
NA.
Half (50%) of the required arterial setback area located closest to the arterial shall be
fully landscaped to enhance the street scene and buffer homes from traffic on adjacent
arterials, and:
Shall contain a minimum of one 24” box tree for every 30 lineal feet of street
frontage; and
Shall be commonly owned and maintained
NA.
Project perimeter walls greater than 42 inches in height shall not be located in
the required landscaped portion of the arterial setback, except noise
attenuation walls that:
Are required by a noise study, and
Due to topography, are necessary to be placed within the required
landscaped portion of the arterial setback.
NA.
C.3
Permitted
Intrusions
into
Setbacks/
Building
Separation
Permitted intrusions into required building setbacks shall be the same as specified in
Section 21.46.120 of this code. The same intrusions specified in Section 21.46.120 shall
be permitted into required building separation.
Project Complies. All intrusions (i.e.,
roof eaves and balconies) into the
required setbacks and building
separation meet Section 21.46.120.
C.4 Streets
Private
Minimum right-of-way width 56 feet
NA. Project is not proposing a private
street.
Minimum curb-to-curb width 34 feet
Minimum parkway width (curb
adjacent) 5.5 feet, including curb
Minimum sidewalk width 5 feet (setback 6 inches from property
line)
Public
Minimum right-of-way width 60 feet
NA. Project is not proposing a public
street.
Minimum curb-to-curb width 34 feet
Minimum parkway width (curb
adjacent) 7.5 feet, including curb
Minimum sidewalk width 5 feet (setback 6 inches from property
line)
Street Trees
within
parkways
One-family dwellings and twin
homes on small-lots
A minimum of one street tree (24-inch
box) per lot is required to be planted in
the parkway along all streets.
NA.
Condominium projects
Street trees shall be spaced no further
apart than 30 feet on center within the
parkway.
NA.
Tree species should be selected to create a unified image for the street,
provide an effective canopy, avoid sidewalk damage and minimize water
consumption.
NA.
PLANNED DEVELOPMENTS (CMC SECTION 21.45.060)
TABLE C: GENERAL DEVELOPMENT STANDARDS
(APPLIES TO LOTS 1 AND 2)
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
C.5 Drive-aisles
3 or fewer
dwelling
units
Minimum 12 feet wide when the drive-aisle is not required for
emergency vehicle access, as determined by the Fire Chief. NA. If the drive-aisle is required for emergency vehicle access, it shall be a
minimum of 20 feet wide.
4 or more
dwelling
units
Minimum 20 feet wide.
Project complies. Access to the four (4)
detached single-family condominium
units proposed on Lot 1 includes a 20 ft.
wide private drive-aisle connecting to
Camino de Las Ondas. The private drive-
aisle meets the minimum 20 ft. width
requirement.
All projects
No parking shall be permitted within the minimum required width of a
drive-aisle.
Project complies. No parking is proposed
within the minimum required width of
the proposed private drive-aisle.
A minimum 24-foot vehicle back-up/maneuvering area shall be
provided in front of garages, carports or uncovered parking spaces (this
may include driveway area, drive-aisles, and streets).
Project complies. A minimum 24-foot
vehicle back-up/maneuvering area is
provided in front of the proposed
garages and guest parking spaces.
Additional width may be required for vehicle/emergency vehicle
maneuvering area. NA.
Parkways and/or sidewalks may be required.
Project complies. The private drive-aisle
serving the four (4) detached single-
family condominium units proposed on
Lot 1 includes a sidewalk along the west
side of the drive-aisle connecting with
Camino de Las Ondas.
No more than 24 dwelling units shall be located along a single-entry
drive-aisle.
Project complies. Less than 24 dwelling
units are proposed adjacent to the
private drive-aisle that is included as part
of Lot 1.
All drive-aisles shall be enhanced with decorative pavement.
Project complies. The private drive-aisle
serving the four (4) detached single-
family condominium units proposed on
Lot 1 is enhanced with decorative
permeable pavers.
C.6
Number
of Visitor
Parking
Spaces
Required
(1)
Projects with 10 units or fewer A .30 space per each unit. Project complies. The project is
proposing five (5) dwelling units total (4
units on Lot 1 and 1 unit on Lot 2). A five
(5) unit project requires two (2) visitor
parking spaces (5 x 0.30 = 1.5 = 2). Lot 1
provides three (3) visitor parking spaces
located off of the interior motor court.
Lot 2, with the custom single-family
homes, has capacity to accommodate its
visitor parking within a 30 ft. long
driveway (see Section C.7 below).
Projects 11 units or more A .25 space per each unit.
When calculating the required number of visitor parking spaces, if the calculation
results in a fractional parking space, the required number of visitor parking spaces
shall always be rounded up to the nearest whole number.
PLANNED DEVELOPMENTS (CMC SECTION 21.45.060)
TABLE C: GENERAL DEVELOPMENT STANDARDS
(APPLIES TO LOTS 1 AND 2)
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
C.7
Location
of
Visitor
Parking
On Private/
Public
Streets
On-street visitor parking is permitted on private/public streets, subject
to the following:
The private/public street is a minimum 34-feet wide (curb-to-curb)
There are no restrictions that would prohibit on-street parking where
the visitor parking is proposed
The visitor parking spaces may be located:
o Along one or both sides of any private/public street(s) located
within the project boundary, and
o Along the abutting side and portion of any existing public/private
street(s) that is contiguous to the project boundary
NA.
In parking bays along public/private streets within the project
boundary, provided the parking bays are outside the minimum
required street right-of-way width.
NA.
When visitor parking is provided as on-street parallel parking, not less
than 24 lineal feet per space, exclusive of driveway/drive-aisle
entrances and aprons, shall be provided for each parking space, except
where parallel parking spaces are located immediately adjacent to
driveway/drive-aisle aprons, then 20 lineal feet may be provided.
NA.
Within the Beach Area Overlay Zone, on-street parking shall not count
toward meeting the visitor parking requirement. NA.
On
Drive-aisles
Visitor parking must be provided in parking bays that are located
outside the required minimum drive-aisle width.
Project complies. The three (3) visitor
parking spaces proposed on Lot 1 are
located within parking bays outside of
the minimum drive-aisle width.
On a
Driveway
Outside the
Beach Area
Overlay
Zone
One required visitor parking space may be credited for
each driveway in a project that has a depth of 40 feet or
more.
NA.
For projects with 10 or fewer units, all required visitor
parking may be located within driveways (located in front
of a unit’s garage), provided that all dwelling units in the
project have driveways with a depth of 20 feet or more.
NA.
Within the
Beach Area
Overlay
Zone
One required visitor parking space may be credited for
each driveway in a project that has a depth of 40 feet or
more.
NA.
If the streets within and/or adjacent to the project allow
for on-street parking on both sides of the street, then
visitor parking may be located in a driveway, subject to the
following:
All required visitor parking may be located within
driveways (located in front of a unit’s garage), provided
that all dwelling units in the project have driveways with
a depth of 20 feet or more.
If less than 100% of the driveways in a project have a
depth of 20 feet or more, then a .25 visitor parking space
will be credited for each driveway in a project that has a
depth of 20 feet or more (calculations resulting in a
fractional parking space credit shall always be rounded
down to the nearest whole number).
NA.
All
projects
The minimum driveway depth required for visitor parking
(20 feet or 40 feet) applies to driveways for front or side-
loaded garages, and is measured from the property line,
back of sidewalk, or from the edge of the drive-aisle,
whichever is closest to the structure.
Project complies. The custom single-
family home proposed on Lot 2 includes
a 30 ft. long driveway, which can
accommodate visitor parking. This
dimension is measured from the
property line to the garage face.
PLANNED DEVELOPMENTS (CMC SECTION 21.45.060)
TABLE C: GENERAL DEVELOPMENT STANDARDS
(APPLIES TO LOTS 1 AND 2)
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
Compact
Parking
For projects of more than 25 units, up to 25% of visitor parking may be
provided as compact spaces (8 feet by 15 feet). No overhang is
permitted into any required setback area or over sidewalks less than 6
feet wide.
NA.
For all projects within the Beach Area Overlay Zone, up to 55% of the
visitor parking may be provided as compact spaces (8 feet by 15 feet). NA.
Distance
from unit
Visitor parking spaces must be located no more than 300 feet as
measured in a logical walking path from the entrance of the unit it
could be considered to serve.
Project complies. Visitor parking is
located closer than 300 ft.
C.8
Screening
of Parking
Areas
Open parking areas should be screened from adjacent residences and public rights-
of-way by either a view-obscuring wall, landscaped berm, or landscaping, except
parking located within a driveway.
Project complies. Visitor parking on Lot
1, is appropriately screened with
landscaping; and its distance,
approximately 120 ft. from Camino de
Las Ondas, is such that the visitor parking
bays will not be visible to the public right-
of-way. This requirement is not
applicable to Lot 2 where visitor parking
is accommodated within the driveway of
the proposed home.
C.9
Community
Recreational
Space (1)
Community recreational space shall be provided for all projects of 11 or more
dwelling units, as follows:
NA. Minimum community
recreational space
required
Project is NOT within RH
general plan designation 200 square feet per unit
Project IS within RH general
plan designation 150 square feet per unit
Projects with 11 to
25 dwelling units
Community recreational space shall be provided as either (or
both) passive or active recreation facilities. NA.
Projects with 26 or
more dwelling
units
Community recreational space shall be provided as both
passive and active recreational facilities with a minimum of
75% of the area allocated for active facilities.
NA.
Projects with 50 or
more dwelling units
Community recreational space shall be provided as both
passive and active recreational facilities for a variety of age
groups (a minimum of 75% of the area allocated for active
facilities).
NA.
For projects consisting of one-family dwellings or twin homes
on small-lots, at least 25% of the community recreation space
must be provided as pocket parks.
Pocket park lots must have a minimum width of 50 feet
and be located at strategic locations such as street
intersections (especially “T-intersections”) and where
open space vistas may be achieved.
NA.
All projects
(with 11 or more
dwelling units)
Community recreational space shall be located and designed
so as to be functional, usable, and easily accessible from the
units it is intended to serve.
NA.
Credit for indoor recreation facilities shall not exceed 25% of
the required community recreation area. NA.
Required community recreation areas shall not be located in
any required front yard and may not include any streets,
drive-aisles, driveways, parking areas, storage areas, slopes
of 5% or greater, or walkways (except those walkways that
are clearly integral to the design of the recreation area).
NA.
Recreation Area
Parking
In addition to required resident and visitor parking,
recreation area parking shall be provided, as follows: 1 space
for each 15 residential units, or fraction thereof, for units
NA.
PLANNED DEVELOPMENTS (CMC SECTION 21.45.060)
TABLE C: GENERAL DEVELOPMENT STANDARDS
(APPLIES TO LOTS 1 AND 2)
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
located more than 1,000 feet from a community recreation
area.
The location of recreation area parking shall be subject to the
same location requirements as for visitor parking, except that
required recreation area parking shall not be located within a
driveway(s).
NA.
Examples of recreation facilities include, but are not limited to, the following:
Active
Swimming pool area
Children’s playground equipment
Spa
Courts (tennis, racquetball, volleyball, basketball)
Recreation rooms or buildings
Horseshoe pits
Pitch and putt
Grassy play areas with a slope of less than 5% (minimum area of 5,000 square feet and a minimum
dimension of 50 feet)
Any other facility deemed by the City Planner to satisfy the intent of providing active recreational facilities.
Passive
Benches
Barbecues
Community gardens
Grassy play areas with a slope of less than 5%.
C.10 Lighting Lighting adequate for pedestrian and vehicular safety shall be provided.
Project complies. Pedestrian scaled path
lighting is proposed along the sidewalk
and private drive-aisle leading from
Camino de Las Ondas back to the four (4)
detached single-family condominium
units.
C.11 Reserved
C.12
Recreational
Vehicle (RV)
Storage (1)
Required for projects with 100 or more units, or a master or specific plan with 100
or more planned development units. Exception: RV storage is not required for
projects located within the RMH or RH land use designations.
NA. 20 square feet per unit, not to include area required for driveways and approaches.
Developments located within master plans or residential specific plans may have
this requirement met by the common RV storage area provided by the master plan
or residential specific plan.
RV storage areas shall be designed to accommodate recreational vehicles of various
sizes (i.e. motorhomes, campers, boats, personal watercraft, etc.). NA.
The storage of recreational vehicles shall be prohibited in the front yard setback
and on any public or private streets or any other area visible to the public. A
provision containing this restriction shall be included in the covenants, conditions
and restrictions for the project. All RV storage areas shall be screened from
adjacent residences and public rights-of-way by a view-obscuring wall and
landscaping.
NA.
PLANNED DEVELOPMENTS (CMC SECTION 21.45.060)
TABLE C: GENERAL DEVELOPMENT STANDARDS
(APPLIES TO LOTS 1 AND 2)
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
C.13 Storage
Space
480 cubic feet of separate storage space per unit. Project complies. Each of the four (4)
detached single-family condominium
units proposed on Lot 1 and the custom
single-family home proposed on Lot 2
include a two-car garage (20 ft. x 20 ft.
minimum interior space), which satisfies
the storage space requirement.
If all storage for each unit is located in one area, the space may be reduced to 392
cubic feet.
Required storage space shall be separately enclosed for each unit and be
conveniently accessible to the outdoors. Project complies.
Required storage space may be designed as an enlargement of a covered parking
structure provided it does not extend into the area of the required parking stall,
and does not impede the ability to utilize the parking stall (for vehicle parking).
Project complies.
A garage (12’x20’ one-car, 20’x20’ two-car, or larger) satisfies the required storage
space per unit. Project complies.
This requirement is in addition to closets and other indoor storage areas. Project complies.
(1) This standard does not apply to housing for senior citizens (see Chapter 21.84 of this code).
ATTACHMENT 5
PLANNED DEVELOPMENTS (CMC SECTION 21.45.070)
TABLE D: ONE-FAMILY DWELLINGS AND TWIN-HOMES ON SMALL LOTS
(APPLIES TO LOT 2 – CUSTOM SINGLE-FAMILY HOME)
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
D.1
Livable
Neighbor-
hood Policy
Must comply with city council Policy 66, Principles for the Development of Livable
Neighborhoods. SEE SEPARATE COMPLIANCE CHART
D.2 Architectural
Requirements
Must comply with city council Policy 44, Neighborhood Architectural Design
Guidelines. NA to one (1) custom single-family home.
D.3 Minimum Lot
Area
One-family
dwellings 5,000 square feet (one dwelling per lot)
Project complies. The custom single-
family home proposed on Lot 2 is
situated on a lot greater than 5,000 sq. ft.
(7,123 sq. ft. proposed).
Twin-homes 3,750 square feet (one dwelling per lot) NA
Exception
3,500 square feet (one-family or twin-home - one dwelling per lot)
when either:
1. The project site contains sensitive biological resources as identified
in the Carlsbad habitat management plan; or
2. The site has a general plan designation of RMH and unique
circumstances such as one of the following exists:
a. The project is for lower income or senior citizen housing;
b. The site is located west of Interstate 5;
c. The dwelling units are designed with alley-loaded garages; or
d. The site is either located contiguous to a Circulation Element
roadway or within 1200 feet of a commuter rail/transit center,
commercial center or employment center.
NA
D.4 Maximum Lot
Coverage
1 story
homes 60% of the net pad area NA
Homes
with 2 or
more
stories
45% of the net pad area for all lots in a project, if the minimum lot
area in the project is 5,000 square feet or greater.
Project complies. The custom single-
family home proposed on Lot 2 has a lot
coverage that is less than 45% (34.6%
proposed).
50% of the net pad area for all lots in a project, if the minimum lot area
in the project is less than 5,000 square feet. NA
Porches with no livable space above the porch, and porte-cocheres no more than 20
feet in width and 6 feet in depth are exempt from lot coverage requirements.
D.5
Minimum
Lot Width
(1)
One-family dwellings on lots equal to
or greater than 5,000 square feet
50 feet (35 feet when a lot is located on a
cul-de-sac, or the curved portion of a
sharply curved street/drive-aisle)
Project complies. Lot 2 proposes a lot
width equal to 71 ft.
One-family dwellings on lots less than
5,000 square feet
40 feet (35 feet when a lot is located on a
cul-de-sac, or the curved portion of a sharply
curved street/drive-aisle)
NA
Twin-homes 35 feet NA
D.6
Minimum
Street/Drive-
Aisle Frontage
Lots located on the curved portion of sharply curved streets/drive-aisles or cul-de-
sacs: 25 feet. NA
D.7
Minimum
Setback
from a Private
or Public
Street(2) (3)
Residential
structure 10 feet
Project complies. Camino de Las Ondas is
a public street. The site plan proposes a
setback ≥10 ft. to the face of the
proposed residential structure.
Direct entry
garage 20 feet
Project complies. Camino de Las Ondas is
a public street. The site plan proposes a
setback ≥20 ft. to the face of the
proposed garage.
PLANNED DEVELOPMENTS (CMC SECTION 21.45.070)
TABLE D: ONE-FAMILY DWELLINGS AND TWIN-HOMES ON SMALL LOTS
(APPLIES TO LOT 2 – CUSTOM SINGLE-FAMILY HOME)
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
D.8
Minimum
Setback
from a
Drive-
Aisle(4)
Residential
structure
5 feet, fully landscaped (walkways providing access to dwelling
entryways may be located within required landscaped area) NA
Garage
3 feet NA
Garages facing directly onto a drive-aisle shall be equipped with an
automatic garage door opener. NA
Projects of 25
units or less
within the
RMH and RH
general plan
designations
0 feet (residential structure and garage) NA
Garages facing directly onto a drive-aisle shall be equipped with an
automatic garage door opener. NA
D.9
Minimum
Interior
Side Yard
Setback
One-family
dwellings Option 1 Residential
structure
Each interior side yard setback shall be a minimum of 10%
of the lot width; provided that each side yard setback is
not less than 5 feet, and need not exceed 10 feet.
Project complies. The lot width for Lot 2
is 71 ft. 10% of 71 ft. = 7.1 ft. The
proposed custom single-family home is
setback greater than 7.1 ft. along both
the east and west sides.
Garage
Located on the front half of
the lot
Same as required for
residence.
Project complies. The garage is located
on the front half of the lot and is setback
greater than 7.1 ft. along the east side.
No living space is proposed above the
garage.
Located on the rear half of
the lot Need not exceed 5 feet NA
Any living space above a garage shall observe the same
interior side yard setback required for the residence.
NA. No living space is proposed above the
garage. Option 2 Residential
structure &
Garage
One interior side yard setback may be reduced to 0 feet
(zero lot line); provided the other side yard setback is a
minimum of 20% of the lot width, and need not exceed 20
feet.
NA
Twin-
homes
One side yard – 0 feet (the side yard where the dwellings on each lot
are attached).
The other side yard setback shall be a minimum of 20% of the lot
width, and need not exceed 20 feet.
NA
D.10
Minimum
Rear Yard
Setback
(where the
rear
property
line does
not front
on a street
or drive-
aisle)
Residential
structure
20% of lot width, provided the rear yard setback is not less than 10
feet, and need not exceed 20 feet.
Project complies. 20% of 71 ft. = 14.2 ft.
Project is proposing a rear yard setback
14.2 ft.
Garage
(located on the
rear half of the
lot)
5 feet from rear property line
NA Any living space above a garage shall observe the same rear yard
setback required for “residence”, above.
D.11
Maximum
Building
Height/
Number of
Stories
Same as required by the underlying zone, and not to exceed three stories (5)(8)
For underlying zoning, which this site
does not have, staff is applying the R-1
development standards as it relates to
this condition so as to be consistent with
the surrounding residential community.
The R-1 zone shall not exceed 30 ft. with
a 3:12 pitched roof or 24 ft. for less than
a 3:12 pitched roof. The height of the
custom single-family home is ≤30 ft. (27’-
11” at its highest point) with a 4:12 roof
pitch.
PLANNED DEVELOPMENTS (CMC SECTION 21.45.070)
TABLE D: ONE-FAMILY DWELLINGS AND TWIN-HOMES ON SMALL LOTS
(APPLIES TO LOT 2 – CUSTOM SINGLE-FAMILY HOME)
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
D.12
Private
Recreation
al Space
Minimum total area per unit 400 square feet (may consist of more
than one recreational space)
Project complies. The custom single-
family home has a rear yard private
recreational area of approximately 2,090
sq. ft.
Minimum dimension of recreational space 15 feet
Project complies. The 2,090 sq. ft. private
rear yard recreational space achieves the
minimum 15 ft. dimension.
Required private recreational space shall be located at ground level and designed so as
to be functional, usable, and easily accessible from the dwelling it is intended to serve,
and shall not have a slope gradient greater than 5%.
Project complies. The required private
recreational space is flat, functional,
usable, and easily accessible from the
dwelling.
Required private recreational space shall not be located within front yard setback
areas, and may not include any driveways, parking areas, storage areas, or walkways
(except those walkways that are clearly integral to the design of the recreation area).
Project complies. The required private
recreational space is not located within
the front yard setback area, and is free of
any driveways, parking areas, storage
areas, and walkways.
Open or lattice-top patio covers may be located within the required private recreation
space (provided the patio cover complies with all applicable standards, including the
required setbacks specified in Section 21.45.090).
Project complies. There are no open or
lattice-top patio covers proposed within
the required private recreational space.
Attached solid patio covers and decks/balconies may project into a required private
recreational space, subject to the following:
The depth of the projection shall not exceed 6 feet (measured from the wall of the
dwelling that is contiguous to the patio/deck/balcony).
The length of the projection shall not be limited, except as required by any setback
or lot coverage standards.
The patio cover/deck/balcony shall comply with all applicable standards, including
the required setbacks specified in Section 21.45.090.
Project complies. There are no attached
solid patio covers, decks or balconies
projecting into the required private
recreational space.
D.13 Resident
Parking
2 spaces per unit,
provided as
either:(6)
a two-car garage (minimum 20 feet x 20 feet), or Project complies. Project floor plans
propose a two car garage with a
minimum 20 ft. x 20 ft. interior
dimension. 2 separate one-car garages (minimum 12 feet x 20 feet each)
D.14
Garages for
3 or more
cars-in-a-
row
No more than 20% of the total project units may include garages with doors for 3 or
more cars-in-a-row that directly face the street, including garages constructed as 3
one-car garages located adjacent to each other, or constructed as a two-car garage
separated from a one-car garage with all garage doors directly parallel to the street.
NA
Garages that are recessed 20 feet or more back from the forward-most plane of the
house shall not be subject to the 20% 3-car garage limitation stated above. NA
Garages with doors for 3 or more cars in-a-row shall not be permitted on lots less
than 5,000 square feet in area. NA
D.15 Driveways Driveways for side-loaded garages must be enhanced with decorative pavement to
improve appearance. NA
(1) Lot width is measured 20’ behind the front property line.
(2) See Table C in Section 21.45.060 for required setbacks from an arterial street.
(3) Building setbacks shall be measured from one of the following (whichever is closest to the building): a) property line; or b) the outside edge of
the required street right-of-way width.
(4) Building setbacks shall be measured from one of the following (whichever is closest to the building): a) property line; b) the outside edge of the
required drive-aisle width; c) the back of sidewalk; or d) the nearest side of a parking bay located contiguous to a drive-aisle (excluding parking
located in a driveway in front of a unit’s garage)..
(5) If a project is located within the Beach Area Overlay Zone, building height shall be subject to the requirements of Chapter 21.82 of this code.
(6) The required resident parking within the R-W zone shall be 2 spaces/unit, 1 of which must be covered. Any uncovered required parking space
in the R-W zone may be located within a required front yard setback and may be tandem.
(7) Garage location standards do not apply to projects where all garages are alley loaded.
(8) Protrusions above the height limit shall be allowed pursuant to Section 21.46.020 of this code. Such protrusions include protective barriers for
balconies and roof decks.
ATTACHMENT 6
PLANNED DEVELOPMENTS (CMC SECTION 21.45.080)
TABLE E: CONDOMINIUM PROJECTS
(APPLIES TO LOT 1)
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
E.1
Livable
Neighborhood
Policy
Must comply with city council Policy 66, Principles for the Development of Livable
Neighborhoods. SEE SEPARATE COMPLIANCE CHART
E.2 Architectural
Requirements
One-family and
two-family
dwellings
Must comply with city council Policy 44, Neighborhood
Architectural Design Guidelines SEE SEPARATE COMPLIANCE CHART
Multiple-family
dwellings
There shall be at least three separate building planes on all
building elevations. The minimum offset in planes shall be 18
inches and shall include, but not be limited to, building walls,
windows, and roofs.
NA. The project proposes detached one-
family condominium units with exclusive
use areas.
All building elevations shall incorporate a minimum of four
complimentary design elements, including but not limited to:
A variety of roof planes;
Windows and doors recessed a minimum of 2 inches;
Decorative window or door frames;
Exposed roof rafter tails;
Dormers;
Columns;
Arched elements;
Varied window shapes;
Exterior wood elements;
Accent materials such as brick, stone, shingles, wood, or siding;
Knee braces; and
Towers.
NA. The project proposes detached one-
family condominium units with exclusive
use areas.
E.3 Maximum
Coverage 60% of total project net developable acreage.
Project complies. Total building
coverage for the four (4) proposed one-
family detached condominium units is
less than 60% (24.9%).
E.4
Maximum
Building
Height
Same as required by the underlying zone, and not to exceed three stories (1)(7)
For underlying zoning, which this site
does not have, staff is applying the R-1
development standards as it relates to
this condition so as to be consistent with
the surrounding residential community.
Building height in the R-1 zone shall not
exceed 30 ft. with a 3:12 pitched roof or
24 ft. for less than a 3:12 pitched roof.
Plan A proposes a building height of 25’-
6” with a 4:12 pitched roof. Plan B
proposes a building height of 25’-7” with
a 4:12 pitched roof. Both plans are two-
stories. Project complies.
Projects within
the RH general
plan designation
(1)(7)
40 feet, if roof pitch is 3:12 or greater
NA. Project site is designated RM. 35 feet, if roof pitch is less than 3:12
Building height shall not exceed three stories
PLANNED DEVELOPMENTS (CMC SECTION 21.45.080)
TABLE E: CONDOMINIUM PROJECTS
(APPLIES TO LOT 1)
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
E.5
Minimum
Building
Setbacks
From a
private or
public
street(2)(3)
Residential
structure 10 feet NA. The four (4) proposed detached
one-family condominium units with
exclusive use areas are accessed from a
drive-aisle.
Direct entry
garage 20 feet
From a drive-
aisle(4)
Residential
structure (except
as specified
below)
5 feet, fully landscaped (walkways providing
access to dwelling entryways may be located
within required landscaped area)
Project complies. The four (4) proposed
detached one-family condominium units
include fully landscaped residential
setbacks that range between 15.37 ft.
and 27.75 ft. as measured from the face
of the garage to the edge of motor court
located at the end of the drive-aisle
leading back from Camino de Las Ondas.
Residential
structure –directly
above a garage
0 feet when projecting over the front of a garage.
Project complies. No portion of the
second floor living space is projecting
over the front of the garage.
Garage
3 feet
Project complies. The four (4) proposed
detached one-family condominium units
include fully landscaped residential
setbacks that range between 15.37 ft.
and 27.75 ft. as measured from the face
of the garage to the edge of motor court
located at the end of the drive-aisle
leading back from Camino de Las Ondas.
Garages facing directly onto a drive-aisle shall be
equipped with an automatic garage door opener.
Project complies. The Plan A & B
exterior elevations include a note
indicating that the garages are equipped
with insulated roll-up garage doors and
automatic openers.
Projects of 25
units or less
within the RMH
and RH general
plan designations
0 feet (residential structure and garage) NA. Project site is designated RM.
Garages facing directly onto a drive-aisle shall be
equipped with an automatic garage door opener. NA. Project site is designated RM.
Balconies/decks
(unenclosed and
uncovered)
0 feet
Project complies. None of the proposed
balconies are cantilevered over the
drive-aisle.
May cantilever over a drive-aisle, provided the
balcony/deck complies with all other applicable
requirements, such as:
Setbacks from property lines
Building separation
Fire and Engineering Department
requirements
From the perimeter property
lines of the project site
(not adjacent to a
public/private street)
The building setback from an interior side or rear
perimeter property line shall be the same as
required by the underlying zone for an interior
side or rear yard setback.
For underlying zoning, which this site
does not have, staff is applying the R-1
development standards as it relates to
this condition so as to be consistent with
the surrounding residential community.
The proposed site plan is appropriately
showing a 10 ft. interior side yard and 20
ft. rear yard setback consistent with
Sections 21.10.070 and 21.10.080 of the
Carlsbad Municipal Code. Project
complies.
PLANNED DEVELOPMENTS (CMC SECTION 21.45.080)
TABLE E: CONDOMINIUM PROJECTS
(APPLIES TO LOT 1)
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
E.6
Minimum
Building
Separation
10 feet The project proposes a building
separation ≥10 ft. Project complies.
E.7 Resident
Parking (6)
All dwelling
types
If a project is located within the RH general plan designation,
resident parking shall be provided as specified below, and may also
be provided as follows:
25% of the units in the project may include a tandem two-car
garage (minimum 12 feet x 40 feet).
Calculations for this provision resulting in a fractional unit may
be rounded up to the next whole number.
NA. Project site is designated RM.
One-family
and two-
family
dwellings
2 spaces per unit, provided as either:
a two-car garage (minimum 20 feet x 20 feet), or
2 separate one-car garages (minimum 12 feet x 20 feet each)
In the R-W Zone, the 2 required parking spaces may be provided
as 1 covered space and 1 uncovered space (5)
Project complies. Each of the four (4)
one-family condominium units provides
a two (2) car garage with a minimum
interior dimension of 20 ft. by 20 ft.
Multiple-
family
dwellings
Studio and one-
bedroom units
1.5 spaces per unit, 1 of which must be covered (5)
NA. Project proposes detached one-
family condominiums, which include
attached two-car garages.
When calculating the required number of parking
spaces, if the calculation results in a fractional
parking space, the required number of parking
spaces shall always be rounded up to the nearest
whole number.
Units with two or
more bedrooms
2 spaces per unit, provided as either:
a one-car garage (12 feet x 20 feet) and 1
covered or uncovered space; or (5)
a two-car garage (minimum 20 feet x 20 feet),
or
2 separate one-car garages (minimum 12 feet x
20 feet each)
In the R-W Zone and the Beach Area Overlay
Zone, the 2 required parking spaces may be
provided as 1 covered space and 1 uncovered
space (5)
NA. Project proposes detached one-
family condominiums, which include
attached two-car garages.
Required parking may be provided within an enclosed parking
garage with multiple, open parking spaces, subject to the following:
Each parking space shall maintain a standard stall size of 8.5 feet
by 20 feet, exclusive of supporting columns; and
A backup distance of 24 feet shall be maintained in addition to a
minimum 5 feet turning bump-out located at the end of any stall
series.
NA. Project proposes detached one-
family condominiums, which include
attached two-car garages.
Required resident parking spaces shall be located no more than 150
feet as measured in a logical walking path from the entrance of the
units it could be considered to serve.
NA. Project proposes detached one-
family condominiums, which include
attached two-car garages.
PLANNED DEVELOPMENTS (CMC SECTION 21.45.080)
TABLE E: CONDOMINIUM PROJECTS
(APPLIES TO LOT 1)
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
E.8
Private
Recreational
Space
One-family,
two-family,
and
multiple-
family
dwellings
Required private recreational space shall be designed so as to be
functional, usable, and easily accessible from the dwelling it is
intended to serve.
Project complies. Private recreational
space, as required below, is designed to
be functional, usable and easily
accessible from the dwelling it is
intended to serve.
Required private recreational space shall be located adjacent to the
unit the area is intended to serve.
Project complies. Private recreational
space, as required below, is located
adjacent to the unit it is intended to
serve.
Required private recreational space shall not be located within any
required front yard setback area, and may not include any
driveways, parking areas, storage areas, or common walkways.
Project complies. Private recreational
space, as required below, is not located
within any required front yard setback
area; and does not include any
driveways, parking areas, storage areas
or common walkways.
One-family
and two-
family
dwellings
Minimum
total area per
unit
Projects not within the RMH or
RH general plan designations 400 square feet
Project complies. Each unit provides a
private recreational space, which ranges
in size from 556 sq. ft. to 794 sq. ft.
Projects within the RMH or RH
general plan designations 200 square feet NA. Project site is designated RM.
May consist of more than one recreational space. NA. Each unit provides all of its private
recreational space in one location.
May be provided at ground level and/or as a deck/balcony on a
second/third floor or roof.
Project complies. Each unit provides its
private recreational space at ground
level.
If provided at
ground level
Minimum
dimension
Not within the RMH
or RH general plan
designations
15 feet
Project complies. Each private
recreational space meets the minimum
15 ft. dimension.
Within the RMH or
RH general plan
designations
10 feet NA. Project site is designated RM.
Shall not have a slope gradient greater than 5%.
Project complies. The area of each
private recreational space is located on a
flat portion of the yard with a slope
gradient of less than 5%.
Attached solid patio covers and decks/balconies
may project into a required private recreational
space, subject to the following:
The depth of the projection shall not exceed 6
feet (measured from the wall of the dwelling
that is contiguous to the patio/deck/balcony).
The length of the projection shall not be limited,
except as required by any setback or lot coverage
standards.
Project complies. Both the Plan A and
Plan B homes include a balcony
extending off the master bedroom on
the second floor and projecting over the
private recreational space. The depth of
the projection is less than 6 ft.
Open or lattice-top patio covers may be located
within the required private recreation space
(provided the patio cover complies with all
applicable standards, including the required
setbacks).
Project complies. There are no open or
lattice-top patio covers proposed.
If provided
above ground
level as a
deck/balcony or
roof deck
Minimum dimension 6 feet
NA. Private recreational space is being
provided at ground level. Minimum area 60 square feet
PLANNED DEVELOPMENTS (CMC SECTION 21.45.080)
TABLE E: CONDOMINIUM PROJECTS
(APPLIES TO LOT 1)
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
Multiple-family
dwellings
Minimum total area per unit (patio, porch, or
balcony) 60 square feet
NA. Project proposes detached one-
family condominiums with exclusive use
areas.
Minimum dimension of patio, porch or balcony 6 feet
NA. Project proposes detached one-
family condominiums with exclusive use
areas.
Projects of 11 or more units that are within the RH general plan
designation may opt to provide an additional 75 square feet of
community recreation space per unit (subject to the standards
specified in Table C of this Chapter), in lieu of providing the per unit
private recreational space specified above.
NA. Project proposes detached one-
family condominiums with exclusive use
areas.
(1) If a project is located within the Beach Area Overlay Zone, building height shall be subject to the requirements of Chapter 21.82 of this code.
(2) See Table C in Section 21.45.060 for required setbacks from an arterial street.
(3) Building setbacks shall be measured from the outside edge of the required street right-of-way width, whichever is closest to the building.
(4) Building setbacks shall be measured from one of the following (whichever is closest to the building): a) the outside edge of the required drive-
aisle width; b) the back of sidewalk; or c) the nearest side of a parking bay located contiguous to a drive-aisle (excluding parking located in a
driveway in front of a unit’s garage).
(5) Any uncovered required parking space in the R-W zone may be located within a required front yard setback and may be tandem.
(6) This standard does not apply to housing for senior citizens (see Chapter 21.84 of this code).
(7) Protrusions above the height limit shall be allowed pursuant to Section 21.46.020 of this code. Such protrusions include protective barriers
for balconies and roof decks.
ATTACHMENT 7
CITY COUNCIL POLICY NO. 44 – NEIGHBORHOOD ARCHITECTURAL DESIGN GUIDELINES
(APPLIES TO LOT 1 – DETACHED SINGLE-FAMILY CONDOMINIUMS)
Architectural Guideline Compliance Comments
Floor Plans and Elevations
1 All residential projects shall be required to have a minimum number of
different floor plans, different front and corresponding matching rear
elevations with different color schemes as identified below:
2-4 dwelling units shall provide 1 floor plan and 2 different
elevations.
5-12 dwelling units shall provide 2 different floor plans and 2
different elevations.
13-20 dwelling units shall provide 2 different floor plans and 3
different elevations.
21+ dwelling units shall provide 3 different floor plans and 3
different elevations.
Project complies. Project
proposes two (2) floor plans and
two (2) different elevations (Plans
A and B). Plan B also offers an
alternate elevation between the
two units that includes a stone
veneer on a portion of the lower
floor and front porch support
column. This alternate Plan B
elevation is being proposed on
Unit 3.
2 Every house should have a coherent architectural style. All elevations of
a house, including front, side and rear, should have the same design
integrity of forms, details and materials.
Project complies. The project
proposes an architectural style
consistent with Spanish and Santa
Barbara architectural styles. Each
elevation incorporates forms,
detailing, and materials on all
elevations that supports the
styles of architecture proposed.
3 In addition to the previous requirements, design details should reinforce
and enhance the architectural form and style of every house and differ
from other elevations of the same floor plan. A minimum of 4
complimentary design details, including but not limited to those listed
below, shall be incorporated into each of the front, rear and street side
building façade(s) of the house.
Design Details
Project complies. A minimum of
four (4) complementary design
details are used to reinforce and
enhance the architectural form
and style of the proposed homes.
Balconies
Decorative eaves and fascia
Exposed roof rafter tails
Arched elements
Towers
Knee braces
Dormers
Columns
Exterior wood elements
Accent materials (i.e.; brick,
stone, shingles, wood or siding)
4 Floor plans in a project shall exhibit a variety of roof ridges and roof
heights within a neighborhood.
Project complies. Plans A and B
each exhibit a variety of roof
ridges and roof heights.
5-8 NA to projects of 2-4 homes.
CITY COUNCIL POLICY 44 – NEIGHBORHOOD ARCHITECTURAL DESIGN GUIDELINES CONTINUED
(APPLIES TO LOT 1 - DETACHED SINGLE-FAMILY CONDOMINIUMS)
Architectural Guideline Compliance Comments
Single Story Requirements
9 The remaining total number of homes shall comply with one of the
following guidelines:
The home shall have a single-story building edge with a depth of
not less than 8 feet and shall run the length of the building along
one side except for tower elements. The roof covering the single-
story element shall incorporate a separate roof plane and shall be
substantially lower than the roof for the two-story element.
Porches and porte-cochere elements shall qualify as a single-story
edge. Houses with courtyards that are a minimum of 15 feet wide
located along the side of the house and setback a minimum of 15
feet from the property line are not required to have a single-story
building edge.
The home shall have a single-story building edge with a depth of
not less than 5 feet and shall run the length of the building along
one side. The roof of the single-story element shall be
substantially lower than the roof for the two-story element of the
building.
The home shall have a single-story building edge with a depth of
not less than 3 feet for 40% of the perimeter of the building.
Project complies. Each plan
type provides a single-story
building edge with a minimum
depth of five (5) ft. along one
side.
Multiple Building Planes
10 For at least 66% of the homes in a project, there shall be at least 3
separate building planes on street side elevations of lots with 45 feet
of street frontage or less and 4 separate building planes on street side
elevations of lots with a street frontage greater than 45 feet.
Balconies and covered porches qualify as a building plane.
The minimum offset in planes shall be 18 inches and shall include, but
not be limited to, building walls, windows, porches and roofs. The
minimum depth between the faces of the forward-most plane and
the rear plane on the front elevation shall be 10 feet. A plane must
be a minimum of 30 sq. ft. to receive credit under this section.
Project complies. 66% of the 4
units = 2.64 units or 3 units
when rounded up. All four (4)
units proposed (Plans A and B)
include three (3) or more
building planes on the front
elevations facing the private
motor court area. Each plane
complies with the minimum 18-
inch offset and meets the
minimum 30 sq. ft.
requirement. Lastly, the
minimum 10 ft. depth between
the forward-most and rear
plane on the front elevation is
achieved.
CITY COUNCIL POLICY 44 – NEIGHBORHOOD ARCHITECTURAL DESIGN GUIDELINES CONTINUED
(APPLIES TO LOT 1 - DETACHED SINGLE-FAMILY CONDOMINIUMS)
Architectural Guideline Compliance Comments
Multiple Building Planes
11 Rear elevations shall adhere to the same criteria outlined in Number
10 above for front elevations except that the minimum depth
between front and back planes on the rear elevation shall be 4 feet.
Rear balconies qualify as a building plane.
Project complies. 66% of the 4
units = 2.64 units or 3 units
when rounded up. Plans A and
B proposed for Units 2, 3 and 4
include three (3) separate
building planes on their rear
elevations. Each plane complies
with the minimum 18-inch
offset and meets the minimum
30 sq. ft. requirement.
Furthermore, the minimum 4 ft.
depth between the forward-
most and rear plane on the rear
elevation is achieved; and a
balcony is included as one of the
required planes.
Windows/Doors
13 At least 66% of exterior openings (door/windows) on every home in
the project shall be recessed or projected a minimum of 2 inches and
shall be constructed with wood, vinyl or colored aluminum window
frames (no mill finishes).
Project complies. All of the
exterior openings are either
recessed or inset a minimum of
two (2) inches or trimmed with
a minimum 2-inch thick foam
trim. Window are constructed
of vinyl window frames with
decorative mullions.
14 Windows shall reinforce and enhance the architectural form and style
of the house through, the use of signature windows and varied
window shapes and sizes.
Project complies. All windows
have a decorative foam trim and
4-inch deep foam sill texture
coated to match the proposed
stucco.
Front Porches
15 Fifty percent (50%) of the homes shall be designed with a covered
front porch, open courtyard, or balcony (each with a minimum depth
of 6 feet and a minimum area of 60 square feet) located at the front
of the dwelling. The minimum depth for a covered front porch shall
be measured from the front facade of the home to the inside of any
supporting porch posts. The front and sides of porches shall be open
except for required and/or ornamental guardrails. A variety of roof
elements shall be provided over porches. Porches may not be
converted to living space.
Project complies. 50% of 4 units
= 2 units. The Plan B proposed
for Units 2 and 3 are designed
with a front porch with a
minimum depth of 6 feet and a
minimum area of 60 square feet
as measured from the front
facade of the home to the inside
of the supporting porch posts.
CITY COUNCIL POLICY 44 – NEIGHBORHOOD ARCHITECTURAL DESIGN GUIDELINES CONTINUED
(APPLIES TO LOT 1 - DETACHED SINGLE-FAMILY CONDOMINIUMS)
Architectural Guideline Compliance Comments
Front Entries
16 Seventy-five percent (75%) of the homes must have a front entry to
the home that is clearly visible from the street. Walkways from the
front door to the street are encouraged.
Project complies. All units have
a front entry that is clearly
visible to the interior motor
court and drive-aisle.
Chimneys
17 Chimneys and chimney caps shall be in scale with the size of the
home. No more than 2 chimneys shall be allowed for homes on lots
in planned developments having an area less than 7,500 square feet.
NA. None of the proposed units
include a chimney.
Garage Doors
18 Garage doors for 3 or 4 cars in a row that directly face the street
must have a minimum of an 18” plane change between the garage
doors after the 2 car garage door.
NA. None of the proposed units
include garages that
accommodate more than two
cars.
Note #1: Fractional units of .5 or greater shall be rounded up to the next whole number and located in a manner
to achieve the best project design as determined by the project planner. When a percentage of units are
described in the guidelines, the intent is to have that percentage spread throughout the entire project.
ATTACHMENT 8
CITY COUNCIL POLICY NO. 66 – LIVABLE NEIGHBORHOODS
(APPLIES TO LOTS 1 AND 2)
Principle Compliance Comments
1 Building Facades, Front Entries, Porches
Facades create interest and character and should be
varied and articulated to provide visual interest to
pedestrians. Clearly identifiable front doors and
porches enhance the street scene and create
opportunities for greater social interaction within the
neighborhood. Building entries and windows should
face the street. Front porches, bay windows,
courtyards and balconies are encouraged.
The proposed building facades create visual
interest and character, which are varied and
articulated to promote visual interest to
pedestrians and neighboring homes. Plans A and
B on Lot 1 along with the custom single-family
home on Lot 2 each include porches that face the
interior motor court area and the Camino de Las
Ondas street frontage, which are inviting and
help to provide an opportunity for social
interaction and visual interest within the
neighborhood. In addition to front porches, the
custom single-family home on Lot 2 includes a
large balcony overlooking the Camino de Las
Ondas street frontage.
2 Garages
Homes should be designed to feature the residence as
the prominent part of the structure in relation to the
street. A variety of garage configurations should be
used to improve the street scene. This may include
tandem garages, side-loaded garages, front-loaded
garages, alley-loaded garages and recessed garages.
The unique constraints of this small infill site limit
the project’s ability to produce a variety of
garage configurations as envisioned under this
guideline (i.e., side-loaded and/or alley loaded
garages). In addition, the narrowness and small
size of this infill project site combined with the
Planned Development regulations and minimum
private rear yard area requirements further
impede the design and development of tandem
or deeply recessed rear yard garage type
configurations. To ensure an improved street
scene for Lot 1, the proposed motor court, drive-
aisle and individual driveways have been
enhanced with decorative pavers, and dense
landscaping in the front yards of each unit. For
Lot 2, the custom single-family home proposes a
front-loaded recessed garage design that is
setback approximately 30 ft. from the back of
sidewalk along Camino de Las Ondas. The home
design incorporates features to insure that the
residence is the prominent part of the structure
in relation to this street (i.e., living room with
large windows, 2nd floor balcony, and front
porch).
CITY COUNCIL POLICY 66 – LIVABLE NEIGHBORHOODS
(APPLIES TO LOTS 1 AND 2)
Principle Compliance Comments
3 Street Design
An interconnected, modified (grid) street pattern
should be incorporated into project designs when
there are no topographic or environmental constraints.
Interconnected streets provide pedestrians and
automobiles many alternative routes to follow,
disperse traffic and reduce the volume of cars on any
one street in the neighborhood. Streets should be
designed to provide both vehicular and pedestrian
connectivity by minimizing the use of cul-de-sacs.
The street network should also be designed to create
a safer, more comfortable pedestrian and bicycling
environment. Local residential streets should have
travel and parking lanes, be sufficiently narrow to
slow traffic, provide adequate access for emergency
and service vehicles and emergency evacuation routes
for residents and include parkways with trees to form
a pleasing canopy over the street. Local residential
streets are the public open space in which children
often play and around which neighborhoods interact.
Within this context, vehicular movement should be
additionally influenced through the use of City-
accepted designs for traffic calming measures.
NA. The unique constraints of this small infill site
limit the project’s ability to provide an
interconnected, modified (grid) street pattern.
4 Parkways
Street trees should be planted in the parkways along
all streets. Tree species should be selected to create a
unified image for the street, provide an effective
canopy, avoid sidewalk damage and minimize water
consumption.
The project does not propose any public or
private streets. However, a private drive aisle is
proposed leading back to the four (4) single-
family residential condominium units. The drive-
aisle is tree lined with a soldier course of queen
palms on both sides, which creates a unified
image for the drive. These trees are spaced
approximately on 25 ft. centers and will provide
effective canopy and avoid sidewalk damage.
5 Pedestrian Walkways
Pedestrian walkways should be located along or
visible from all streets. Walkways (sidewalks or trails)
should provide clear, comfortable and direct access to
neighborhood schools, parks/plazas and transit stops.
Primary pedestrian routes should be bordered by
residential fronts, parks or plazas. Where street
connections are not feasible (at the end of cul-de-
sacs), pedestrian paths should also be provided.
The project provides a landscape enhanced
pedestrian walkway extending from the four (4)
single-family residential condominium units
proposed on Lot 1 to the public sidewalk along
Camino de Las Ondas. This walkway provides
clear, comfortable and direct access from these
units to the public sidewalk along Camino de Las
Ondas, which leads to neighborhood schools (i.e.,
Pacific Rim Elementary School), parks/plazas (i.e.,
Poinsettia Park) and transit stop locations along
Paseo del Norte. Lot 2, with the proposed
custom single-family home, is located directly
adjacent to Camino de Las Ondas with direct
access to the existing public sidewalk.
CITY COUNCIL POLICY 66 – LIVABLE NEIGHBORHOODS
(APPLIES TO LOTS 1 AND 2)
Principle Compliance Comments
6 Centralized Community Recreation Areas
Park or plazas, which serve as neighborhood meeting
places and as recreational activity centers should be
incorporated into all planned unit developments. As
frequently as possible, these parks/plazas should be
designed for both active and passive uses for
residents of all ages and should be centrally located
within the project. Parks and plazas should be not be
sited on residual parcels, used as buffers from
surrounding developments or to separate buildings
from streets.
NA. Community recreational space is required
for projects consisting of 11 or more units. This
five (5) unit project does not meet the threshold
to require a centralized community recreation
area. Private recreation areas are instead
accommodated through the private recreation
areas in the rear yard of the custom single-family
home proposed on Lot 2 and each of the
exclusive use areas associated with Units 1-4
proposed on Lot 1.
Owner:Golden Surf Holdings LLCFarzan Dehmoubed, Project Manager6798 Paseo Del NorteCarlsbad, Ca 92011Cell 760-688-9962 Fax 905-940-3997 Owners Agent:Karnak Planning & DesignRobert Richardson. PlannerPO Box 810Carlsbad, Ca 92018-0810760-434-8400, Fax 760-683-2269Existing Zoning:Zone SP-20Planned Community PC (No Master Plan approved)Coastal ZoneGeneral Plan:R-M 4-8 6 GMCP4-8 Units per acre GMC Point 6 Units per acreLot Size: 1.08 acresAPN Number: 214-531-51Legal Description: Lot 1 of Parcel Map 6136Project Address: 6798 Paseo Del NorteCarlsbad, Ca 92009Expected Processing:Tentative Subdivision Map CTPlanned Development PUDCoastal Development Permit CDPProcessed as One PhaseTotal Number of Lots: 3Density: 5.5 du/acOccupancy:R-1 All Living spaceS-2 GaragesType V non RatedComply w/ NFPA 13 Fire sprinkler systemCal Green Requirements per City of CarlsbadNo portion of the project is in the noise critical AreaAverage Daily Traffic (ADT)5 residential Units 5x 10= 50 ADTEarthwork:Cut100 cyFill3800 cyImport3700 cyExport0 cyRemedial500 cyRecreation Areas:Custom residence2090 sq.ft.Unit#1556 sq.ft.Unit#2794 sq.ft.Unit#3712 sq.ft.Unit#4560 sq.ft.Note:The developable area of the lot does not have any environmental sensitive lands per Section 21.53.230 of the CMC.CIVIL ENGINEERCHECKED BY:DRAWN BY:DRAWING FILE:PROJECT NO.:PROJECT ADDRESS:GOLDENSURFSpear & Associates, Inc.Josh Zeigler475 Production StreetSan Marcos, CA 92078(760) 736-2040 fax (760) 736-4866JOSH@SPEARINC.NETCLIENT:C1.0 Cover Sheet & DataAS1.0 Conceptual Site PlanAS1.1 Constraints Site PlanAS1.2 Existing Site Conditions & Utilities PlanA1.0 New Custom Home Floor PlansA1.1 New Custom Home Roof PlanA1.2 Custom Home ElevationsA2.0 Plan A Unit 1 Floor PlansA2.1 Plan A Unit 1 Roof PlansA2.2 Plan A Unit 4 Floor PlansA2.3 Plan A Unit 4 Roof PlansA2.4 Plan A Unit 1 ElevationsA2.5 Plan A Unit 4 ElevationsA3.0 Plan B Floor PlansA3.1 Plan B Roof PlansA3.2 Plan B Exterior ElevationsA3.3 Plan B Exterior Elevations (Alternate Lot #3)GEOSOILS INC.5741 PALMER WAYCARLSBAD, CA 92009PH: 760-438-3155 FAX:760-931-0915CONTACT: RYAN BOEHMERPROJECT INFORMATIONDavid MiertschinLandscape ArchitectDMLA34032 Alcazar Drive, Dana point, Ca 92629P/F (949) 388-3369email: david@dmlaonline.comCT 13-04PUD 13-10CDP 13-33DESCRIPTIONDATEPLANNER / DESIGNER:COPYRIGHT 2014SHEET NO.:SHEET TITLE:ACOUSTIC ENGINEERSHEET INDEXCONSULTANT INFORMATIONABC Acoustics, Inc.Sharo T. Savanvi990 Highland DriveSuite 212Solano Beach, Ca 92075email: sharo@abcacoustics.comJanuary 20,20156798 Paseo Del NorteCarlsbad, Ca 92011Golden Surf Holdings, LLC6798 Paseo Delk NorteCarlsbad, Ca 9201111LANDSCAPEL-1 Preliminary Landscape PlanL-2 Water Conservation PlanL-3 Existing Constraints Landscape PlanL-4 Conceptual Water & Maintenance PlansCIVIL ENGINEERING2013 CALIFORNIA BUILDING CODE (BASED ON 2012 IBC)2013 CALIFORNIA MECHANICAL CODE (BASED ON 2012 UMC)2013 CALIFORNIA PLUMBING CODE (BASED ON 2012 UPC)2013 CALIFORNIA ELECTRICAL CODE (BASED ON 2012 NEC)2013 CALIFORNIA FIRE CODE (BASED ON 2012 IFC)2013 CALIFORNIA ADA BUILDING CODE (BASED ON 2012 CBC TITLE 24)APPLICABLE CITY OF CARLSBAD CODES AND ORDINANCESGOVERNING CODESARCHITECTURALPLANNING & ARCHITECTURALKARNAK PLANNING & DESIGN2525 PIO PICO DRIVE, SUITE 102CARLSBAD, CA 92008PH: 760-434-8400CONTACT: ROBERT RICHARDSON, PLANNERLANDSCAPE ARCHITECTSOILS ENGINEER6798 PASEO DEL NORTE, CARLSBAD, CA 92011C1.0Cover & DataSheetPROJECT:Golden Surf ProjectSTAMP:C-1 Tentative Subdivision MapC-2 Preliminary Grading & Const. PlanC-3 Site SectionsC-4 Impervious Areas PlanCONSULTANT:2802 State Street, Suite C Carlsbad, CA 92008PHONE: 760.434.8400 FAX: 434.8493EMAIL: karnakarch@aol.comKarnak Planning & DesignProject DescriptionDevelop the existing residence and lot (1.08 acres) into three separate projectsThe lots will be broken down as follows:Density: Total Lot 1.08 acres 6du/1.08 acres = 5.55 du/acres Lot #1 Condominium Project of 4 unitsLot Size: 26,451 sq.ft. 0.61 acres Unit BreakdownPlan 1st 2nd Total Garage Balcony PorchesUnit #1A 934 1,279 2,213 544 65 42Unit #2B 1,097 1,159 2,256 504 40 83Unit #3B 1,097 1,159 2,256 504 40 83Unit #4A 934 1,279 2,213 544 40 42Total 8,938 2096 185 250 Lot Coverage: 24.92% ( 6,593 sq.ft.)Condominium Units to conform to Chapter 1 A section 1102 A of the 2013 CBC Multi-Story Condo UnitsLot #2 Custom ResidenceLot 7123 sq.ft. 0.16 acresResidenceFirst Floor 1865 sq.ft.Second Floor 1385 sq.ft.3250 sq.ft.2 Car Garage424 sq.ft.Balcony 174 sq.ft.Porches 178 sq.ft.Lot coveraged 34.6% (2467 sq.ft.) Setbacks ProposedFront: 29'-9"' at Garage 10' Front Living RoomSide: 7'-10"' (East side garage at 7'-10"' and west side at 8')Rear: +/- 22'-11"' NE Corner'Lot #3 Existing Residence to remainLot 13,598 sq.ft. 0.31 acresGarage 794 sq.ft.2nd Dwelling Unit 638 sq.ft.Occupany: R & S Type V non rated2nd dwelling Type V one hourLot Coverage3044 sq.ft. 32.3%SetbacksFront: Approximately 23'-6" Side: West side approxiately 15' and 10' east side Rear: 20'Water/Sewer District:City of CarlsbadProposed Sewer Generation: 5 EDUSchool District:Carlsbad Unfied School DistrictProposed Drainage (CFS): Q100 = 2.0 CFSMaster Drainage Basin: Basins C/DProposed Water Demand: All residences must have minimum 1" meters Fire DepartmentResidence 550 per x 5 = 2750 GPD
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSGARAGEGARAGE19'10'10'20'10'17'-2"18'-9"20'-11"18'15'-4"9'-11"10'10'10'8'-10"10'-3"10'9'-4"10'10'-6"16'-5"17'-6"28'-7"9'8'-6"8'-6"8'-6"1 5 '-2 "N00D32'19"W 115.95'74.98'N00D35'41"W 140.36'N89D00'16"W 149.99'N00D32'26"W 256.39'N88D59'20"W 225.11'CAMINO DE LAS ONDASPASEO DEL NORTELANDS END COURT10'LOT 3LOT 2LOT 1712 sq.ft.560 sq.ft.794 sq.ft.556 sq.ft.17.32'2090 sq.ft.27.75'15.37' 17.99'20'18'18'20'CHECKED BY:DRAWN BY:DRAWING FILE:PROJECT NO.:PROJECT ADDRESS:Conceptual Site Plan1"=20'NorthCLIENT:CT 13-04PUD 13-10CDP 13-33DESCRIPTIONDATEPLANNER / DESIGNER:COPYRIGHT 2014SHEET NO.:SHEET TITLE:ConceptualSite PlanAS1.0January 20,2015Guest Parking(3)6798 Paseo Del NorteCarlsbad, Ca 92011Golden Surf Holdings, LLC6798 Paseo Delk NorteCarlsbad, Ca 92011A1A1B2B2B3B3A4A4CustomResidencePROJECT INFORMATIONPROJECT:Golden Surf ProjectSTAMP:Owner:Golden Surf Holdings LLCFarzan Dehmoubed, Project Manager6798 Paseo Del NorteCarlsbad, Ca 92011Cell 760-688-9962 Fax 905-940-3997 Owners Agent:Karnak Planning & DesignRobert Richardson. PlannerPO Box 810Carlsbad, Ca 92018-0810760-434-8400, Fax 760-683-2269Existing Zoning:Zone SP-20Planned Community PC (No Master Plan approved)Coastal ZoneGeneral Plan:R-M 4-8 6 GMCP4-8 Units per acre GMC Point 6 Units per acreLot Size: 1.08 acresAPN Number: 214-531-51Legal Description: Lot 1 of Parcel Map 6136Project Address: 6798 Paseo Del NorteCarlsbad, Ca 92009Expected Processing:Tentative Subdivision Map CTPlanned Development PUDCoastal Development Permit CDPProcessed as One PhaseTotal Number of Lots: 3Density: 5.5 du/acOccupancy:R-1 All Living spaceS-2 GaragesType V non RatedComply w/ NFPA 13 Fire sprinkler systemCal Green Requirements per City of CarlsbadNo portion of the project is in the noise critical AreaAverage Daily Traffic (ADT)5 residential Units 5x 10= 50 ADTEarthwork:Cut100 cyFill3800 cyImport3700 cyExport0 cyRemedial500 cyRecreation Areas:Custom residence2090 sq.ft.Unit#1556 sq.ft.Unit#2794 sq.ft.Unit#3712 sq.ft.Unit#4560 sq.ft.Note:The developable area of the lot does not have any environmental sensitive lands per Section 21.53.230 of the CMC.CONSULTANT:Existing Residence &2nd Dwelling Unit2802 State Street, Suite C Carlsbad, CA 92008PHONE: 760.434.8400 FAX: 434.8493EMAIL: karnakarch@aol.comKarnak Planning & Design123HCADA Path of Travel2010 CALIFORNIA BUILDING CODE (BASED ON 1997 UBC)2010 CALIFORNIA MECHANICAL CODE (2009 UMC)2010 CALIFORNIA PLUMBING CODE (2009 UPC)2010 CALIFORNIA ELECTRICAL CODE (2008 NEC)2010 CALIFORNIA FIRE CODE2005 CALIFORNIA BUILDING CODE (TITLE 24)APPLICABLE CITY OF CARLSBAD CODES AND ORDINANCESGOVERNING CODESProject DescriptionDevelop the existing residence and lot (1.08 acres) into three separate projectsThe lots will be broken down as follows:Density: Total Lot 1.08 acres 6du/1.08 acres = 5.55 du/acres Lot #1 Condominium Project of 4 unitsLot Size: 26,451 sq.ft. 0.61 acres Unit BreakdownPlan 1st 2nd Total Garage Balcony PorchesUnit #1A 934 1,279 2,213 544 65 42Unit #2B 1,097 1,159 2,256 504 40 83Unit #3B 1,097 1,159 2,256 504 40 83Unit #4A 934 1,279 2,213 544 40 42Total 8,938 2096 185 250 Lot Coverage: 24.92% ( 6,593 sq.ft.)Condominium Units to conform to Chapter 1 A section 1102 A of the 2013 CBC Multi-Story Condo UnitsLot #2 Custom ResidenceLot 7123 sq.ft. 0.16 acresResidenceFirst Floor 1865 sq.ft.Second Floor 1385 sq.ft.3250 sq.ft.2 Car Garage424 sq.ft.Balcony 174 sq.ft.Porches 178 sq.ft.Lot coveraged 34.6% (2467 sq.ft.) Setbacks ProposedFront: 29'-9"' at Garage 10' Front Living RoomSide: 7'-10"' (East side garage at 7'-10"' and west side at 8')Rear: +/- 22'-11"' NE Corner'Lot #3 Existing Residence to remainLot 13,598 sq.ft. 0.31 acresGarage 794 sq.ft.2nd Dwelling Unit 638 sq.ft.Occupany: R & S Type V non rated2nd dwelling Type V one hourLot Coverage3044 sq.ft. 32.3%SetbacksFront: Approximately 23'-6" Side: West side approxiately 15' and 10' east side Rear: 20'Water/Sewer District:City of CarlsbadProposed Sewer Generation: 5 EDUSchool District:Carlsbad Unfied School DistrictProposed Drainage (CFS): Q100 = 2.0 CFSMaster Drainage Basin: Basins C/DProposed Water Demand: All residences must have minimum 1" meters Fire DepartmentResidence 550 per x 5 = 2750 GPD
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSGARAGEGARAGE19'10'10'20'10'17'- 2"18'- 9"20'- 11"18'15'- 4"9'-11"10'10'10'8'-10"10'-3"10'9'-4"10'10'-6"16'- 5"17'-6"28 '-7"9'8'-6"8'-6"8'-6"15 '-2 "N00D32'19"W 115.95'74.98'N00D35'41"W 140.36'N89D00'16"W 149.99'N00D32'26"W 256.39'N88D59'20"W 225.11'CAMINO DE LAS ONDASPASEO DEL NORTELANDS END COURT10'LOT 3LOT 2LOT 1712 sq.ft.560 sq.ft.794 sq.ft.556 sq.ft.17.32'2090 sq.ft.27.75'15.37' 17.99'20'18'18'20'CHECKED BY:DRAWN BY:DRAWING FILE:PROJECT NO.:PROJECT ADDRESS:CLIENT:CT 13-04PUD 13-10CDP 13-33DESCRIPTIONDATEPLANNER / DESIGNER:COPYRIGHT 2014SHEET NO.:SHEET TITLE:January 20,20156798 Paseo Del NorteCarlsbad, Ca 92011Golden Surf Holdings, LLC6798 Paseo Delk NorteCarlsbad, Ca 92011PROJECT:Golden Surf ProjectSTAMP:CONSULTANT:2802 State Street, Suite C Carlsbad, CA 92008PHONE: 760.434.8400 FAX: 434.8493EMAIL: karnakarch@aol.comKarnak Planning & DesignConstraints Site Plan1"=30'North100 ft. Limit of InfluenceConstraintsSite PlanAS1.1
CHECKED BY:DRAWN BY:DRAWING FILE:PROJECT NO.:PROJECT ADDRESS:CLIENT:CT 13-04PUD 13-10CDP 13-33DESCRIPTIONDATEPLANNER / DESIGNER:COPYRIGHT 2014SHEET NO.:SHEET TITLE:January 20,2015Existing Site Conditions & UtilitesNo ScaleNorth6798 Paseo Del NorteCarlsbad, Ca 92011Golden Surf Holdings, LLC6798 Paseo Delk NorteCarlsbad, Ca 92011AS1.2Existing SiteConditions & UtilitiesPROJECT:Golden Surf ProjectCrime Prevention ConditionsSTAMP:CONSULTANT:2802 State Street, Suite C Carlsbad, CA 92008PHONE: 760.434.8400 FAX: 434.8493EMAIL: karnakarch@aol.comKarnak Planning & Design
DN8'-3" x 16'-7"13'-6"5'-0"0'-5"12'-8"13'-0"8'-11"12'-8"8'-4"16'-11"8'-2"10'-7"21'-3"14'-7"BedroomOPEN BELOWBedroomBathMaster BathClosetMaster BedroomStairsLaundryMaster Bedroom Balcony174 sq.ft.F.F.E.= 185.0'UP19'-2"20'-5"8'-0"13'-2"21'-0"17'-10"8'-9"5'-0"19'-5"13'-6"15'-7"20'-2"20'-2"Back Porch53 sq.ft.FrontPorch71 sq.ft.DiningFFE 174.0'FFE 171.5'Living RoomEntryPdwrNookGreat RoomBedroom/DenBathroomKitchenDining Porch54 sq.ft.DrivewayGarageNorth1/4" = 1'-0"CHECKED BY:DRAWN BY:DRAWING FILE:PROJECT NO.:PROJECT ADDRESS:Custom Residence First Floor PlanCustom Residence Second Floor Plan1/4" = 1'-0"CLIENT:CT 13-04PUD 13-10CDP 13-33DESCRIPTIONDATEPLANNER / DESIGNER:COPYRIGHT 2014SHEET NO.:SHEET TITLE:January 20,2015A1.0First Floor 1865 sq.ft.Second Floor 1385 sq.ft.Total 3250 sq.ft.Garage 424 sq.ft.Balcony 174 sq.ft.PorchesFront 71 sq.ft.Side 54 sq. ft.Back 53 sq.ft.Lot Coverage:House 1865 sq.ft.Porches 178 sq.ft.Garage 424 sq.ft.Building coverage: 2467 sq.ft.Line of Floor aboveOccupancy: R, SType V non ratedNFPA 13 Fire sprinkler system6798 Paseo Del NorteCarlsbad, Ca 92011Golden Surf Holdings, LLC6798 Paseo Delk NorteCarlsbad, Ca 92011Custom ResidenceFloor PlansCustom ResidencePROJECT:Golden Surf ProjectSTAMP:CONSULTANT:2802 State Street, Suite C Carlsbad, CA 92008PHONE: 760.434.8400 FAX: 434.8493EMAIL: karnakarch@aol.comKarnak Planning & Design
4 : 124 : 124 : 124 : 124 : 124 : 124 : 124 : 124 : 124 : 124 : 124 : 124 : 124 : 124 : 124 : 12A1.1Custom ResidenceRoof PlansCHECKED BY:DRAWN BY:DRAWING FILE:PROJECT NO.:PROJECT ADDRESS:CLIENT:CT 13-04PUD 13-10CDP 13-33DESCRIPTIONDATEPLANNER / DESIGNER:COPYRIGHT 2014SHEET NO.:SHEET TITLE:January 20,20151/4" = 1'-0"Custom Residence First Floor Roof PlanCustom Residence Second Floor Roof Plan1/4" = 1'-0"6798 Paseo Del NorteCarlsbad, Ca 92011Golden Surf Holdings, LLC6798 Paseo Delk NorteCarlsbad, Ca 92011PROJECT:Golden Surf ProjectSTAMP:CONSULTANT:2802 State Street, Suite C Carlsbad, CA 92008PHONE: 760.434.8400 FAX: 434.8493EMAIL: karnakarch@aol.comKarnak Planning & DesignNote:All over hangs are 18" typical both floors.All Roof Slopes are 4:12 pitchDownspoutDownspouts 2x3 with strapping connected to a pvc collectorpipes and discharged to an approved drainage swale per theengineering design.4" PCV or Alum. Gutters
30'-0"18'-0"25'-7"25'-9"16'-9"25'-7"19'-1"27'-11"25'-7"30'-0"NotesCHECKED BY:DRAWN BY:DRAWING FILE:PROJECT NO.:PROJECT ADDRESS:CLIENT:1 Stucco - Spanish Lace Finish2 Wood Railing 42"high3 Concrete Tile Roof 4:12 Pitch Typical4 Foam Fascia Detailing5. Not used6 Not used7 2x12 Horizontal Foam Trim8 Stucco foam Fascia Detail w/ Aluminum 6" Gutter9 Finish Grade10 Roof Gutters11 Window Sill with Foam Molding and Trim12 Stucco column.13. 16' Insulated Roll Up Garage Door & Automatic Remote Control OpenerCT 13-04PUD 13-10CDP 13-33DESCRIPTIONDATEPLANNER / DESIGNER:COPYRIGHT 2014SHEET NO.:SHEET TITLE:January 20,2015Right Side Elevation3/16" = 1'-0"6798 Paseo Del NorteCarlsbad, Ca 920113/16" = 1'-0"Left Side ElevationGolden Surf Holdings, LLC6798 Paseo Delk NorteCarlsbad, Ca 92011Front Elevation3/16" = 1'-0"Rear Elevation3/16" = 1'-0"A1.2Custom ResidenceExterior ElevationsCustom Residence4444PROJECT:Golden Surf ProjectHeight LimitHeight Limit111111223333333388111144449988881111STAMP:4499448888881313111188881111447777887799CONSULTANT:2802 State Street, Suite C Carlsbad, CA 92008PHONE: 760.434.8400 FAX: 434.8493EMAIL: karnakarch@aol.comKarnak Planning & Design412 Typical121212121212
UP6060497'-9"16'-10"5'5'29'-4"27'-7"24'-1"20'-7"21'-6"30'28'-6"24'-7"53'-1"GARAGEFAMILYBATHFAMILYCLOSETFront Porch 42 sq.ft.Plane 1KitchenPlane 2Plane 3Plane 4DN5'13'14'-7"3'-5"13'-7"11'-3"13'-2"5'6'-1"12'-7"19'-8"10'-2"10'-1"5'-11"9'CLOSETBEDROOMOPEN BELOWSTUDYCLOSETMASTER BEDROOMBEDROOMBEDROOMBalcony 65 sq.ft.CHECKED BY:DRAWN BY:DRAWING FILE:PROJECT NO.:Plan AFloor PlansUnit 1PROJECT ADDRESS:Plan A First Floor Plan "Unit 1"CLIENT:1/4"=1'-0"Plan A Second Floor Plan "Unit 1"CT 13-04PUD 13-10CDP 13-33First Floor 934 sq.ft.Second Floor 1279 sq.ft.Total2213 sq.ft.Garage 544 sq.ft.Balcony 65 sq.ft.Front Porch 42 sq.ft.DESCRIPTIONDATEPLANNER / DESIGNER:COPYRIGHT 2014SHEET NO.:SHEET TITLE:January 20,2015A2.0Occupancy: R, SType V non ratedNFPA 130 Fire sprinkler system6798 Paseo Del NorteCarlsbad, Ca 92011Golden Surf Holdings, LLC6798 Paseo Delk NorteCarlsbad, Ca 920111/4"=1'-0"PROJECT:Golden Surf ProjectSTAMP:CONSULTANT:2802 State Street, Suite C Carlsbad, CA 92008PHONE: 760.434.8400 FAX: 434.8493EMAIL: karnakarch@aol.comKarnak Planning & DesignPlan AUnit 1
DN4 : 124 : 124 : 124 : 124 : 124 : 124 : 124 : 12UP4 : 124 : 124 : 124 : 124 : 12CHECKED BY:Plan ARoof PlansDRAWN BY:DRAWING FILE:PROJECT NO.:PROJECT ADDRESS:CLIENT:A2.1CT 13-04PUD 13-10CDP 13-33DESCRIPTIONDATEPLANNER / DESIGNER:COPYRIGHT 2014SHEET NO.:SHEET TITLE:January 20,20156798 Paseo Del NorteCarlsbad, Ca 920111/4" = 1'-0"Plan A First Floor Roof PlanPlan A Second Floor Roof Plan1/4" = 1'-0"Golden Surf Holdings, LLC6798 Paseo Delk NorteCarlsbad, Ca 92011PROJECT:Golden Surf ProjectSTAMP:CONSULTANT:2802 State Street, Suite C Carlsbad, CA 92008PHONE: 760.434.8400 FAX: 434.8493EMAIL: karnakarch@aol.comKarnak Planning & DesignPlan AUnit 1Note:All over hangs are 18" typical both floors.All Roofs are a 4:12 pitch.DownspoutDownspouts 2x3 with strapping connected to a pvc collectorpipes and discharged to an approved drainage swale per theengineering design.4" PCV or Alum. Gutters
UP6060497'-9"16'-10"5'5'29'-4"27'-7"24'-1"20'-7"21'-6"30'28'-6"24'-7"53'-1"GARAGEFAMILYBATHFAMILYCLOSETFront Porch 42 sq.ft.Plane 1KitchenPlane 2Plane 3Plane 4DN5'14'10'4'1'-8"14'-7"3'-5"13'-7"11'-3"13'-2"5'-3"6'-1"12'-10"19'-8"10'-2"10'-1"5'-11"9'CLOSETBEDROOMPlane 1Plane 2Plane 3OPEN BELOWSTUDYCLOSETMASTER BEDROOMBEDROOMBEDROOMBalcony 40 sq.ft.CHECKED BY:DRAWN BY:DRAWING FILE:PROJECT NO.:PROJECT ADDRESS:CLIENT:CT 13-04PUD 13-10CDP 13-33DESCRIPTIONDATEPLANNER / DESIGNER:COPYRIGHT 2014SHEET NO.:SHEET TITLE:January 20,2015Occupancy: R, SType V non ratedNFPA 130 Fire sprinkler systemPlan A First Floor Plan "Unit 4"1/4"=1'-0"6798 Paseo Del NorteCarlsbad, Ca 92011Plan A Second Floor Plan "Unit 4"First Floor 934 sq.ft.Second Floor 1279 sq.ft.Total2213 sq.ft.Garage 544 sq.ft.Balcony 40 sq.ft.Front Porch 42 sq.ft.1/4"=1'-0"A2.2Plan AFloor PlansUnit 4Golden Surf Holdings, LLC6798 Paseo Delk NorteCarlsbad, Ca 92011PROJECT:Golden Surf ProjectSTAMP:CONSULTANT:2802 State Street, Suite C Carlsbad, CA 92008PHONE: 760.434.8400 FAX: 434.8493EMAIL: karnakarch@aol.comKarnak Planning & DesignPlan AUnit 4
DN4 : 124 : 124 : 124 : 124 : 124 : 124 : 124 : 124 : 124 : 12UP4 : 124 : 124 : 124 : 124 : 12CHECKED BY:DRAWN BY:DRAWING FILE:PROJECT NO.:PROJECT ADDRESS:CLIENT:CT 13-04PUD 13-10CDP 13-33DESCRIPTIONDATEPLANNER / DESIGNER:COPYRIGHT 2014SHEET NO.:SHEET TITLE:January 20,20151/4" = 1'-0"6798 Paseo Del NorteCarlsbad, Ca 92011Plan A First Floor Roof PlanPlan A Second Floor Roof PlanGolden Surf Holdings, LLC6798 Paseo Delk NorteCarlsbad, Ca 92011Note:All over hangs are 18" typical both floors.All Roofs are 4:12 pitch1/4" = 1'-0"PROJECT:Golden Surf ProjectSTAMP:CONSULTANT:2802 State Street, Suite C Carlsbad, CA 92008PHONE: 760.434.8400 FAX: 434.8493EMAIL: karnakarch@aol.comKarnak Planning & DesignPlan AUnit 4A2.3Plan ARoof PlansDownspoutDownspouts 2x3 with strapping connected to a pvc collectorpipes and discharged to an approved drainage swale per theengineering design.4" PCV or Alum. Gutters
22'-8"25'-6"30'22'-8"25'-6"30'CHECKED BY:DRAWN BY:DRAWING FILE:PROJECT NO.:PROJECT ADDRESS:CLIENT:CT 13-04PUD 13-10CDP 13-33DESCRIPTIONDATEPLANNER / DESIGNER:COPYRIGHT 2014SHEET NO.:SHEET TITLE:January 20,20156798 Paseo Del NorteCarlsbad, Ca 92011Golden Surf Holdings, LLC6798 Paseo Delk NorteCarlsbad, Ca 92011PROJECT:Golden Surf ProjectSTAMP:CONSULTANT:2802 State Street, Suite C Carlsbad, CA 92008PHONE: 760.434.8400 FAX: 434.8493EMAIL: karnakarch@aol.comKarnak Planning & DesignNotes1 Stucco - Spanish Lace Finish2 Wood Railing 42"high3 Concrete Tile Roof 4:12 pitch Typical4 Foam Fascia Detailing6 Canvas Awning (optional)7 2x12 Horizontal Foam Trim8 Stucco foam Fascia Detail w/ Aluminum 6" Gutter9 Finish Grade10 Not used11 Window Sill with Foam Molding and Trim12 Stucco column.13. 16' Insulated Roll-up Garage Door & Automatic OpenerRight Side Elevation1/4" = 1'-0"1/4" = 1'-0"Left Side ElevationFront ElevationPlan A ExteriorElevations1/4" = 1'-0"Rear Elevation1/4" = 1'-0"A2.4Plan AUnit 1Height LimitHeight Limit412 Typical11112222223333333388888888889999111111111111444411111111121212121313887777
22'-8"25'-6"30'30'25'-6"22'-8"CHECKED BY:DRAWN BY:DRAWING FILE:PROJECT NO.:PROJECT ADDRESS:CLIENT:CT 13-04PUD 13-10CDP 13-33DESCRIPTIONDATEPLANNER / DESIGNER:COPYRIGHT 2014SHEET NO.:SHEET TITLE:January 20,20156798 Paseo Del NorteCarlsbad, Ca 92011Golden Surf Holdings, LLC6798 Paseo Delk NorteCarlsbad, Ca 92011Notes1 Stucco - Spanish Lace Finish2 Wood Railing 42"high3 Concrete Tile Roof 4:12 pitch Typical4 Foam Fascia Detailing6 Canvas Awning (optional)7 2x Horizontal Foam Trim8 Stucco foam Fascia Detail w/ Aluminum 6" Gutter9 Finish Grade10 Not used11 Window Sill with Foam Molding and Trim12 Stucco column.13. 16' Insulated Roll-up Garage Door & Automatic OpenerRight Side Elevation1/4" = 1'-0"1/4" = 1'-0"Left Side ElevationFront ElevationPlan A ExteriorElevations1/4" = 1'-0"Rear Elevation1/4" = 1'-0"A2.5Plan AUnit 4PROJECT:Golden Surf ProjectSTAMP:CONSULTANT:Height LimitHeight Limit2802 State Street, Suite C Carlsbad, CA 92008PHONE: 760.434.8400 FAX: 434.8493EMAIL: karnakarch@aol.comKarnak Planning & Design412 Typical111122223333333388888888889999111111111111444411111111121212121313887777
UPSB42B29DCB36RB36D/WDishwasher (control panel)B18RGas Range [29 1/2W]B30B12RSB42B29DCB36RB36Dishwasher (control panel)B18RGas Range [29 1/2W]B30B12R636346U381790W2736W2736DCW2436RW3036W3018W3918W1236R160806080
6040LS6040LS3040LS60683030LS4016LS2468466810980266850682668411802630LS6040LS6'-8"13'6'23'-10"20'-7"12'-6"19'-10"5'14'3'26'-10"29'-8"15'-8"6'34'21'-6"24'-5"30'-6"54'-11"BEDROOMBEDROOMBATHPlane 1Plane 3Plane 2Plan BGARAGEPlane 4Front Porch83 sq.ft.DNSB36SB42SB42SB42SB36SB42SB42SB42U321896W3436W33362630LS3030LS2630LS4040LS3030FX3030FX3030FX3030FX3030FX5040LS3268236849687068266826682 6 6 8
5036LS5068210742668266866684640LS7'1'-7"10'1'-6"4'14'-10"17'-3"13'13'10'-2"10'-2"OPEN BELOWMASTER BDRMCLOSETHALLBEDROOMBEDROOMCOURTCLOSETBATHPlane 1Plane 2Plane 3Balcony 40 sfMASTER BATHPlan B First Floor PlanCHECKED BY:DRAWN BY:DRAWING FILE:PROJECT NO.:PROJECT ADDRESS:1/4"=1'-0"Plan B Second Floor Plan1/4"=1'-0"CLIENT:First Floor 1097 sq.ft.Second Floor 1159 sq.ft.Total 2256 sq.ft.Garage 504 sq.ft.Balcony 40 sq.ft.Front Porch 75 sq.ft.CT 13-04PUD 13-10CDP 13-33DESCRIPTIONDATEPLANNER / DESIGNER:COPYRIGHT 2014SHEET NO.:SHEET TITLE:January 20,2015Occupancy: R, SType V non ratedNFPA 13 fire sprinkler system6798 Paseo Del NorteCarlsbad, Ca 92011Golden Surf Holdings, LLC6798 Paseo Delk NorteCarlsbad, Ca 92011A3.0Plan BFloor PlansPROJECT:Golden Surf ProjectSTAMP:CONSULTANT:2802 State Street, Suite C Carlsbad, CA 92008PHONE: 760.434.8400 FAX: 434.8493EMAIL: karnakarch@aol.comKarnak Planning & Design
UP4 : 124 : 124 : 124 : 124 : 12DN4 : 124 : 124 : 124 : 124 : 124 : 124 : 124 : 124 : 124 : 124 : 12CHECKED BY:DRAWN BY:DRAWING FILE:PROJECT NO.:PROJECT ADDRESS:CLIENT:CT 13-04PUD 13-10CDP 13-33DESCRIPTIONDATEPLANNER / DESIGNER:COPYRIGHT 2014SHEET NO.:SHEET TITLE:January 20,2015A3.16798 Paseo Del NorteCarlsbad, Ca 920111/4" = 1'-0"Plan B First Floor Roof PlanPlan B Second Floor Roof Plan1/4" = 1'-0"Golden Surf Holdings, LLC6798 Paseo Delk NorteCarlsbad, Ca 92011Plan BRoof PlansNote:All over hangs are 18" typical both floors.All Roofs are 4:12 pitch.PROJECT:Golden Surf ProjectSTAMP:CONSULTANT:2802 State Street, Suite C Carlsbad, CA 92008PHONE: 760.434.8400 FAX: 434.8493EMAIL: karnakarch@aol.comKarnak Planning & DesignDownspoutDownspouts 2x3 with strapping connected to a pvc collectorpipes and discharged to an approved drainage swale per theengineering design.4" PCV or Alum. Gutters
1 Stucco - Spanish Lace Finish2 Wood Railing 42"high3 Concrete Tile Roof 4:12 pitch typical4 Foam Fascia Detailing5. Not used6. Not used7 2x12 Horizontal Foam Trim8 Stucco foam Fascia Detail w/ Aluminum 6" Gutter9 Finish Grade4'30'25'-7"23'-6"CHECKED BY:DRAWN BY:DRAWING FILE:PROJECT NO.:PROJECT ADDRESS:CLIENT:CT 13-04PUD 13-10CDP 13-33DESCRIPTIONDATEPLANNER / DESIGNER:COPYRIGHT 2014SHEET NO.:SHEET TITLE:January 20,20156798 Paseo Del NorteCarlsbad, Ca 92011Golden Surf Holdings, LLC6798 Paseo Delk NorteCarlsbad, Ca 92011Notes10 Not used11 Window Sill with Foam Molding and Trim12 Stucco column.13. 16' Insulated Roll Up Garage Door & Automatic Remote control OpenerRight Side Elevation1/4" = 1'-0"1/4" = 1'-0"Left Side ElevationFront ElevationPlan B ExteriorElevations1/4" = 1'-0"Rear Elevation1/4" = 1'-0"A3.2Plan BPROJECT:Golden Surf ProjectSTAMP:111122333344778888CONSULTANT:991111121211881313111111111212888833332277111133992802 State Street, Suite C Carlsbad, CA 92008PHONE: 760.434.8400 FAX: 434.8493EMAIL: karnakarch@aol.comKarnak Planning & Design412 Typical1'-6"4'25'-7"23'-6"30'
1 Stucco - Spanish Lace Finish2 Wood Railing 42"high3 Concrete Tile Roof 4:12 Pitch typical4 Foam Fascia Detailing6 Not Used7 2x12 Horizontal Foam Trim8 Stucco foam Fascia Detail w/ Aluminum 6" Gutter9 Finish Grade4'30'25'-7"23'-6"CHECKED BY:DRAWN BY:DRAWING FILE:PROJECT NO.:PROJECT ADDRESS:CLIENT:CT 13-04PUD 13-10CDP 13-33DESCRIPTIONDATEPLANNER / DESIGNER:COPYRIGHT 2014SHEET NO.:SHEET TITLE:January 20,20156798 Paseo Del NorteCarlsbad, Ca 92011Golden Surf Holdings, LLC6798 Paseo Delk NorteCarlsbad, Ca 92011Notes10 Roof Gutters11 Window Sill with Foam Molding and Trim12 Stucco column.13. 16' Insulated Roll Up Garage Door & Automatic Remote control Opener14. Coronado Stone Veneer TypicalRight Side Elevation1/4" = 1'-0"1/4" = 1'-0"Left Side ElevationFront ElevationPlan B ExteriorElevations1/4" = 1'-0"Rear Elevation1/4" = 1'-0"A3.3Plan BAlternate ElevationLot #3PROJECT:Golden Surf ProjectSTAMP:CONSULTANT:141414141414141414142802 State Street, Suite C Carlsbad, CA 92008PHONE: 760.434.8400 FAX: 434.8493EMAIL: karnakarch@aol.comKarnak Planning & DesignSee A3.2 for all call outs exceptfor the stone veneer.412 Typical1'-6"4'25'-7"23'-6"30'
1/18/2015 5:57 PM C:\Users\Miertschin\Documents\AutoCAD LT 2002\_DMLA\_CLIENTS\_KAR\KAR_13.01 Golden Surf\Development\13-172BS- LANDSCAPE.dwgPLOT DATE:ALL IDEAS, DESIGNS, & ARRANGEMENTS REPRESENTED HEREON ARE THE PROPERTY OF SPEAR & ASSOCIATES CIVIL ENGINEERING & SHALL BE USED FOR THIS PROJECT ONLY EXCEPT WITH THE WRITTEN PERMISSION OF SAID ENGINEER. ANY CHANGE MADE BY PARTIES OTHER THAN SAID CIVIL ENGINEER SHALL RELIEVE CIVIL ENGINEER OF RESPONSIBILITY FOR THE FACILITY OR AFFECTED PORTION THEREOF. CONTRACTORS SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO THE START OF ANY WORK & SHALL REPORT ANY DISCREPANCY TO THE CIVIL ENGINEER.
ALL IDEAS, DESIGNS, & ARRANGEMENTS REPRESENTED HEREON ARE THE PROPERTY OF SPEAR & ASSOCIATES CIVIL ENGINEERING & SHALL BE USED FOR THIS PROJECT ONLY EXCEPT WITH THE WRITTEN PERMISSION OF SAID ENGINEER. ANY CHANGE MADE BY PARTIES OTHER THAN SAID CIVIL ENGINEER SHALL RELIEVE CIVIL ENGINEER OF RESPONSIBILITY FOR THE FACILITY OR AFFECTED PORTION THEREOF. CONTRACTORS SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO THE START OF ANY WORK & SHALL REPORT ANY DISCREPANCY TO THE CIVIL ENGINEER.1/18/2015 6:30 PM C:\Users\Miertschin\Documents\AutoCAD LT 2002\_DMLA\_CLIENTS\_KAR\KAR_13.01 Golden Surf\Development\13-172BS- LANDSCAPE.dwgPLOT DATE:····························
1/18/2015 5:58 PM C:\Users\Miertschin\Documents\AutoCAD LT 2002\_DMLA\_CLIENTS\_KAR\KAR_13.01 Golden Surf\Development\13-172BS- LANDSCAPE.dwgPLOT DATE:ALL IDEAS, DESIGNS, & ARRANGEMENTS REPRESENTED HEREON ARE THE PROPERTY OF SPEAR & ASSOCIATES CIVIL ENGINEERING & SHALL BE USED FOR THIS PROJECT ONLY EXCEPT WITH THE WRITTEN PERMISSION OF SAID ENGINEER. ANY CHANGE MADE BY PARTIES OTHER THAN SAID CIVIL ENGINEER SHALL RELIEVE CIVIL ENGINEER OF RESPONSIBILITY FOR THE FACILITY OR AFFECTED PORTION THEREOF. CONTRACTORS SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO THE START OF ANY WORK & SHALL REPORT ANY DISCREPANCY TO THE CIVIL ENGINEER.
1/18/2015 5:58 PM C:\Users\Miertschin\Documents\AutoCAD LT 2002\_DMLA\_CLIENTS\_KAR\KAR_13.01 Golden Surf\Development\13-172BS- LANDSCAPE.dwgPLOT DATE:ALL IDEAS, DESIGNS, & ARRANGEMENTS REPRESENTED HEREON ARE THE PROPERTY OF SPEAR & ASSOCIATES CIVIL ENGINEERING & SHALL BE USED FOR THIS PROJECT ONLY EXCEPT WITH THE WRITTEN PERMISSION OF SAID ENGINEER. ANY CHANGE MADE BY PARTIES OTHER THAN SAID CIVIL ENGINEER SHALL RELIEVE CIVIL ENGINEER OF RESPONSIBILITY FOR THE FACILITY OR AFFECTED PORTION THEREOF. CONTRACTORS SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO THE START OF ANY WORK & SHALL REPORT ANY DISCREPANCY TO THE CIVIL ENGINEER.