HomeMy WebLinkAbout2015-08-05; Planning Commission; ; CT 14-05|PUD 14-08|CDP 14-27 - MAGNOLICA TOWNHOMES
The City of Carlsbad Planning Division
A REPORT TO THE PLANNING COMMISSION
Item No.
Application complete date: January 27, 2015
P.C. AGENDA OF: August 5, 2015 Project Planner: Christer Westman
Project Engineer: Steve Bobbett
SUBJECT: CT 14-05/PUD 14-08/CDP 14-27 – MAGNOLIA TOWNHOMES – Request for approval of
a Tentative Tract Map, Planned Development Permit, and Coastal Development Permit
to demolish existing single-family structures and develop a 16-unit multi-family
residential condominium project on a 0.68 acre infill site generally located on the south
side of Magnolia Avenue, west of Jefferson Street, within the Mello II segment of the
Local Coastal Program and in Local Facilities Management Zone 1. The project is not
within the appealable area of the California Coastal Commission. The City Planner has
determined that this project is exempt from the requirements of the California
Environmental Quality Act (CEQA) pursuant to Section 15332 “In-Fill Development
Projects” of the State CEQA Guidelines and will not have any adverse significant impact
on the environment.
I. RECOMMENDATION
That the Planning Commission ADOPT Planning Commission Resolution No. 7116 APPROVING a
Tentative Tract Map (CT 14-05), Planned Development Permit (PUD 14-08), and Coastal Development
Permit (CDP 14-27) based upon the findings and subject to the conditions contained therein.
II. PROJECT DESCRIPTION AND BACKGROUND
The applicant proposes to demolish the existing single-family residential structures on-site, including
homes and detached garages, and develop a 16-unit multi-family residential condominium project on a
0.68-acre infill site located on the south side of Magnolia Avenue, west of Jefferson Street. The
development of the proposed condominium project requires the processing and approval of a Tentative
Tract Map, Planned Development Permit, and Coastal Development Permit.
The site is comprised of two parcels that have been developed with single-family homes and detached
garages. Topographically, the lots slope down moderately from Magnolia Avenue to the southern rear
property lines by approximately 5 feet.
The condominium units are arranged in three buildings flanking a private driveway. The buildings are
two and three stories tall with living areas located on each floor and an attached two-car garage at
driveway grade for each unit. Building “A” is three stories and buildings “B” and “C” are two-stories.
The condominium units in building “A” are 1,565 square feet with three bedrooms and four bathrooms.
The condominium units in building “B” are 1,120 square feet with two bedrooms and two bathrooms.
The condominium units in building “C” are 1,092 square feet with two bedrooms and two bathrooms.
The two units adjacent to Magnolia Avenue have front doors and porches facing the street. The
remaining units in buildings “A” and “C” have side property line facing front doors and all of the units in
building “B” have front doors facing the drive-aisle. Private storage space will be located within each
two car garage. All of the units have direct access to a ground floor patio.
3
CT 14-05/PUD 14-08/CDP 14-27 – MAGNOLIA TOWNHOMES
August 5, 2015
Page 2
A private 24 foot wide decorative, porous pavement drive-aisle will provide access into the project from
Magnolia Avenue. All of the attached 20’ x 20’ resident garages are accessed from the private drive-
aisle. The four required visitor parking spaces are provided offsite along Magnolia Avenue in front of the
project and a single accessible parking space is provided onsite.
The architectural style for the project is an eclectic blend of Spanish elements. The building materials
include stucco, stone veneers, wood, and a decorative colored tile roof. The building colors and accent
trim consists of warm brown and beige/cream tones.
Table “A” below includes the General Plan designations, zoning, and current land uses of the project site
and surrounding properties.
TABLE A
Location General Plan
Designation Zoning Current Land Use
Site Residential R-30 (R-30) Residential Density-Multiple (RD-M) Single-Family
Residential
North Residential Medium
High (RMH) Residential Density-Multiple (RD-M) Single-Family
Residential
South Residential Medium
High (RMH) Residential Density-Multiple (RD-M) Single-Family
Residential
East Residential R-30 (R-30) Residential Density-Multiple (RD-M) Multi-Family Residential
West Residential R-30 (R-30) Residential Density-Multiple (RD-M) Multi-Family Residential
Table “B” below includes the project site’s gross and net acreage, the number of dwelling units allowed
by both the General Plan’s Growth Management Control Point (GMCP) and the Regional Housing Needs
Assessment (RHNA) Base density and the proposed projects number of dwelling units and density.
TABLE B
Gross Acres Net Acres DUs Allowed at GMPC
Density (25 du/ac)
DUs Proposed and
Project Density
0.68 acres 0.68 acres 17 units* 16 units at 23.53 du/ac
*The proposed 16-unit project at a density of 23.53 du/ac is within the Residential R-30 (R-30) density
range of 23 – 30 du/ac yet is under the GMCP of 25 du/ac; however, the project is consistent with the
minimum R-30 Density of 23 du/ac as required by the City’s General Plan. For further information, refer
to the General Plan Land Use designation discussion in the analysis Section “A” below.
In order to meet the City’s Inclusionary Housing requirement, the applicant will need to enter into an
affordable housing agreement to purchase two housing credits prior to final map approval or an
alternative inclusionary housing solution will need to be authorized by the City Council prior to final map
approval.
Grading quantities include 754 cubic yards of cut, 330 cubic yards of fill, and 424 cubic yards of export.
Retaining walls, ranging up to three feet in height will extend along the south and west property lines to
accommodate the project. The Preliminary Geotechnical Investigation prepared for the project,
(September 10, 2014, Strata-Tech, Inc.) concludes that the development is considered feasible provided
the recommendations contained within the Geotechnical Investigation are implemented in the design
and construction which is a minimum 2-foot thick compacted fill blanket below the bottom of the
footings. The project has been conditioned accordingly.
CT 14-05/PUD 14-08/CDP 14-27 – MAGNOLIA TOWNHOMES
August 5, 2015
Page 3
The project meets the City’s standards for planned developments and subdivisions, and as designed and
conditioned, is in compliance with the General Plan, Subdivision Ordinance, and relevant zoning
regulations of the Carlsbad Municipal Code.
III. ANALYSIS
The project is subject to the following regulations:
A. Residential R-30 (R-30) General Plan Land Use designation;
B. Residential Density Multiple Zone (RD-M) and Planned Development regulations (Chapters
21.24, and 21.45 of the Carlsbad Municipal Code);
C. City Council Policy No. 66 (Principals for the Development of Livable Neighborhoods);
D. Subdivision Ordinance (Title 20 of the Carlsbad Municipal Code);
E. Inclusionary Housing Ordinance (Chapter 21.85 of the Zoning Ordinance);
F. Local Coastal Program; and
G. Growth Management Ordinance (Chapter 21.90 of the Zoning Ordinance) and Zone 6 Local
Facilities Management Plan.
The recommendation for approval of this project was developed by analyzing the project’s consistency
with the applicable regulations and policies. The project’s compliance with each of the above
regulations is discussed in detail in the sections below.
A. General Plan Residential R-30 (R-30) Land Use Designation
The General Plan Land Use designation for the property is Residential R-30 (R-30). The R-30 designation
allows for the development of two-family and multiple-family residential units within a density range of
23 – 30 dwelling units per acre with a Growth Management Control Point (GMCP) of 25 dwelling units
per acre. The project site has a net developable acreage of 0.68 acres. At the GMCP, 17 dwelling units
would be permitted on this 0.68 net developable acre property. Although the project is below the
GMCP for the R-30 General Plan Land Use designation by 1 dwelling unit, the General Plan Land Use
Element allows the City to approve residential development at a density that is below the GMCP for the
applicable density range provided that the proposed residential density (23.53 du/ac -16 dwelling units)
is within the R-30 density range of 23 – 30 du/ac. Consistent with Program 3.2 of the City’s certified
General Plan Housing Element, all of the dwelling units which were anticipated toward achieving the
City’s share of the regional housing needs that are not used by developers in approved projects will be
deposited in the City’s Excess Dwelling Unit Bank. The project will deposit one dwelling unit into the
bank and it will then be available for allocation to another project. Accordingly, there is no net loss of
residential unit capacity and there are adequate properties identified in the Housing Element allowing
residential development with a unit capacity, including second dwelling units, adequate to satisfy the
City’s share of the regional housing need.
The project complies with the Elements of the General Plan as outlined in Table C below:
CT 14-05/PUD 14-08/CDP 14-27 – MAGNOLIA TOWNHOMES
August 5, 2015
Page 4
TABLE C – GENERAL PLAN COMPLIANCE
ELEMENT
USE, CLASSIFICATION, GOAL,
OBJECTIVE OR PROGRAM
PROPOSED USES &
IMPROVEMENTS COMPLIANCE
Land Use
Site is designated for Residential R-
30 density, (R-30 – 23-30 du/ac)
with a GMPC 25 du/ac.; 17 dwellings
units could be constructed on the
site.
The 16 unit residential project
has a density of 23.53 dwelling
units per acre which is within
the R-30 density range of 23 –
30 du/ac.
Yes
Housing Provision of affordable housing. The project is conditioned to
enter into an affordable housing
agreement to purchase two (2)
housing credits prior to final
map approval.
Yes
Public Safety Reduce fire hazards to an
acceptable level.
The project meets the fire code.
The project is required to
provide an automatic sprinkler
system within each dwelling unit
and is located within a five
minute response time of Fire
Station No. 1.
Yes
Open Space &
Conservation
Minimize the environmental
impacts to sensitive resources
within the City.
Utilize Best Management Practices
for control of storm water and to
protect water quality.
The project will not have any
environmental impacts to the
previously developed site.
The project is conditioned to
conform to all NPDES
requirements and has been
designed to include Low Impact
Design (LID) elements.
Yes
Yes
Noise Comply with the residential exterior
noise standard of 60 dB(A) CNEL in
private recreation areas and interior
noise standard of 45 dB(A) CNEL.
The proposed project is not
located within an area of 65
dB(A) CNEL noise standard.
Measures are conditioned for
the project to comply with the
interior 45dB(A) CNEL noise
standard for residential uses.
Yes
Circulation Construct roadway improvements
needed to serve proposed
development.
All public facilities including
curb, gutter and sidewalk exist
along the property frontage
(Magnolia Avenue).
Yes
B. Residential Density-Multiple Zone (RD-M)/Planned Development Regulations
The proposed project is required to comply with all applicable use and development standards of the
Carlsbad Municipal Code (CMC) including the Residential Density-Multiple Zone (CMC Chapter 21.24)
and the Planned Development Regulations (CMC Chapter 21.45).
CT 14-05/PUD 14-08/CDP 14-27 – MAGNOLIA TOWNHOMES
August 5, 2015
Page 5
The RD-M zone allows for the development of multi-family residential housing and the Planned
Development (PD) Ordinance allows for the development of a condominium ownership project in the
RD-M zone. The PD Ordinance provides most of the development standards with the exception of those
standards included in Table D below for a 16-unit residential airspace condominium project. The project
complies with all applicable development standards of the PD Ordinance. Refer to Attachments No. 4
and 5 for an analysis of the project compliance with Tables C & E of the Planned Development
Ordinance. The proposed project, which consists of 3 buildings, two two-story and one three-story
structures with attached garages, and a maximum building height of 33 feet 9 inches with a roof pitch of
5:12, is compatible with the existing surrounding and proposed multi-family condominium and
apartment projects. All public facilities including curb, gutter and sidewalk have been constructed along
the property frontage. The building elevations have been designed to include elements currently found
in the neighborhood in order to blend into the surrounding development.
TABLE D – RD-M ZONE COMPLIANCE
RD-M Standards Required Provided
Setbacks Interior Side Yard: 5 feet
Rear: 10 feet minimum
Interior Side Yard: 5 feet
Rear: 10 feet
Minimum Lot Area 10,000 square feet .68 acre (29,621 square feet)
C. City Council Policy No. 66 (Livable Neighborhoods)
The project complies with City Council Policy No. 66 (Livable Neighborhoods). Refer to Attachment No.
6 for an analysis of project compliance with City Council Policy No. 66, Livable Neighborhoods.
D. Subdivision Ordinance
The project includes sixteen (16) residential air-space condominium units and is therefore subject to the
regulations of Chapter 20.16 of the Subdivision Ordinance. These subdivision regulations require the
project to include required street dedications and improvements (streets, sewer, water, and drainage)
to serve the proposed subdivision.
The Land Development Engineering Division has reviewed the proposed Tentative Map and has
concluded that the subdivision, as conditioned, complies with all the applicable requirements of the
Subdivision Map Act and the City’s Subdivision Ordinance. Magnolia Avenue is a publicly dedicated
roadway and no additional improvements or dedication of streets is required. All infrastructure
improvements, including street frontage, drainage, sewer, and water facilities exist. General utility and
access easements will be dedicated to allow for the construction of project drainage, sewer, and water
facilities on the final map.
No standards variances are needed to approve the project. Given the above, the proposed subdivision
would provide all necessary facilities and improvements without producing land conflicts; therefore, the
project is consistent with the Subdivision Ordinance.
E. Inclusionary Housing Ordinance
The proposed project involves the creation of sixteen residential units through a subdivision and,
therefore, must provide affordable housing to lower-income households as specified in the Inclusionary
Housing Ordinance (Chapter 21.85 of the Zoning Ordinance). For residential development of seven or
more units, not less than fifteen percent of the total units approved shall be constructed and restricted
CT 14-05/PUD 14-08/CDP 14-27 – MAGNOLIA TOWNHOMES
August 5, 2015
Page 6
both as to occupancy and affordability to lower-income households. This 16 unit project is therefore
responsible for providing two inclusionary units. Whenever reasonably possible, inclusionary units
should be built on the residential development project site. However, based on the project’s small size,
the Housing Policy Team is recommending support of the applicant entering into an affordable housing
agreement prior to final map approval to purchase two housing credits or an alternative solution will
need to be authorized to satisfy their inclusionary housing obligations prior to final map approval.
Therefore, the applicant has been conditioned to satisfy the inclusionary housing requirement for lower-
income households by entering into an Affordable Housing Agreement to purchase two (2) credits prior
to final map approval or an alternative solution will need to be authorized, subject to City Council
approval. By entering into the agreement prior to final map approval the project is providing its fair
share of housing affordable to lower income households and, therefore, is consistent with the
Inclusionary Housing Ordinance.
F. Local Coastal Program
The project site is located within the Mello II Segment of the Local Coastal Program, but is not within the
appealable jurisdiction of the California Coastal Commission. The site is also located within and subject
to the Coastal Resources Protection Overlay Zone. The project’s compliance with each of these
programs and ordinances is discussed below:
1. Mello II Segment of the Certified Local Coastal Program and all applicable policies.
The project is located in the Mello II Segment of the Local Coastal Program. One of the primary
requirements of the applicable coastal regulations pertains to the conversion of agricultural land to
urban use. The project site is not identified as a “Map X - Designated Coastal Agricultural Lands” and
therefore, is not required to be preserved nor is it subject to an agricultural conversion mitigation fee.
The project is further consistent with the policies of the Coastal Act in that, a) the site is geologically
stable; b) the project has been designed to reduce the amount of runoff off-site through the use of Low
Impact Development (LID) design features and has been conditioned to implement the National
Pollution Discharge Elimination System (NPDES) standards; c) the project does not preclude any
recreational opportunities or shoreline access as the property is not located adjacent to any waterways
or bodies of water; and d) the development does not obstruct views of the coastline as seen from public
lands or public rights-of-way.
2. Coastal Resource Protection Overlay Zone
The project is consistent with the provisions of the Coastal Resource Protection Overlay Zone (C.M.C.
Chapter 21.203) in that the project will adhere to the City’s Master Drainage Plan, Grading Ordinance,
Storm Water Ordinance, Standard Urban Storm Water Mitigation Plan (SUSMP) and Jurisdictional Urban
Runoff Management Program (JURMP) to avoid increased urban run-off, pollutants and soil erosion. No
development is proposed in areas of natural steep slopes (≥25% gradient) and no native vegetation is
located on the subject property. In addition, the site is not located in an area prone to landslides, or
susceptible to accelerated erosion, floods or liquefaction.
G. Growth Management
The proposed project is located within Local Facilities Management Zone 1 in the northwest quadrant of
the City. The impacts on public facilities created by the project, and its compliance with the adopted
performance standards, are summarized in Table E below.
CT 14-05/PUD 14-08/CDP 14-27 – MAGNOLIA TOWNHOMES
August 5, 2015
Page 7
TABLE E – GROWTH MANAGEMENT COMPLIANCE
STANDARD IMPACTS COMPLIANCE
City Administration 55.60 sq. ft. Yes
Library 29.66 sq. ft. Yes
Waste Water Treatment 16 EDU Yes
Parks .12 acre Yes
Drainage 2 CFS Yes
Circulation 128 ADT Yes
Fire Station No. 1 Yes
Open Space 0 acres N/A
Schools Carlsbad (E=2.73/M=1.34/HS = 1.17) Yes
Sewer Collection System 16 EDUs Yes
Water 4,000 GPD Yes
The project proposes 16 dwelling units whereas the maximum unit yield at the GMCP of the property is
17 dwelling units. The proposed 16-unit project is 1 unit below the Growth Management Control Point
density for this R-30 designated property. Consistent with the General Plan and Policy No. 43, 1 DU will
be deposited into the City’s excess dwelling unit bank.
IV. ENVIRONMENTAL REVIEW
The City Planner has determined that the project belongs to a class of projects that the State Secretary
for Resources has found do not have a significant impact on the environment, and it is therefore
categorically exempt from the requirement for the preparation of environmental documents pursuant
to Section 15332 (In-Fill Development Projects) Class 32 Categorical Exemption of the State CEQA
Guidelines. The project is consistent with the General Plan as well as with the Zoning Ordinance, the
project site is within the City limits, is less than 5 acres in size, and is surrounded by urban uses; there is
no evidence that the site has value as habitat for endangered, rare, or threatened species; approval of
the project will not result in significant effects relating to traffic, noise, air quality, or water quality; and
the site can be adequately served by all required utilities and public services. In making this
determination, the City Planner has found that the exceptions listed in Section 15300.2 of the state
CEQA Guidelines do not apply to this project. A Notice of Exemption will be filed by the City Planner
upon final project approval.
ATTACHMENTS:
1. Planning Commission Resolution No. 7116
2. Location Map
3. Disclosure Statement
4. Planned Development Compliance Table C
5. Planned Development Compliance Table E
6. City Council Policy No. 66
7. Letter dated July 9, 2015 from John Bailey
8. Letter dated July 14, 2015 from John Bailey
9. Reduced Exhibits
10. Full Size Exhibits “A – J” dated August 5, 2015
MAGNOLIA AV
J
E
F
F
E
R
S
O
N
S
T
ANCHOR WY
MAGNOLIA TOWNHOMESCT 14-05/PUD 14-08/CDP 14-27
SITE MAP
J
SITE
EL
CAMINO
R
E
A
LLA COSTA AV
A L G A R D
C
A
R
L
S
B
A
D
B
L
ATTACHMENT NO. 4
PLANNED DEVELOPMENTS (CMC SECTION 21.45.060)
TABLE C: GENERAL DEVELOPMENT STANDARDS
APPLICABLE TO ALL PLANNED DEVELOPMENTS
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
C.1 Density
Per the underlying General Plan designation. When two or more general plan land use designations exist within a planned development, the density may be transferred from one general plan designation to another with a general plan amendment.
The R-30 General Plan Land Use designation has a density range of 23-30 dwelling units per acre. The project density is 23.53 du/ac.
C.2 Arterial Setbacks
All dwelling units adjacent to any arterial road shown on the Circulation Element of the General Plan shall maintain the following minimum setbacks from the right-of-way:
Prime Arterial 50 Feet Major Arterial 40 Feet Secondary Arterial 30 Feet Carlsbad Boulevard 20 Feet
N/A
Half (50%) of the required arterial setback area located closest to the arterial shall be fully landscaped to enhance the street scene and buffer homes from traffic on adjacent arterials, and:
Shall contain a minimum of one 24” box tree for every 30 lineal feet of street frontage; and Shall be commonly owned and maintained
N/A
Project perimeter walls greater than 42 inches in height shall not be located in the required landscaped portion of the arterial setback, except noise attenuation walls that: Are required by a noise study, and
Due to topography, are necessary to be placed within the required
landscaped portion of the arterial setback.
N/A
C.3
Permitted
Intrusions into Setbacks/ Building Separation
Permitted intrusions into required building setbacks shall be the same as specified in Section 21.46.120 of this code. The same intrusions specified in Section 21.46.120 shall be permitted into required building separation.
An 18” built-out window surround is included at the master bedroom windows on the second floor of building “B”
C.4 Streets
Private
Minimum right-of-way width 56 feet
N/A
Minimum curb-to-curb width 34 feet
Minimum parkway width (curb
adjacent) 5.5 feet, including curb
Minimum sidewalk width 5 feet (setback 6 inches from property line)
Public
Minimum right-of-way width 60 feet
N/A
Minimum curb-to-curb width 34 feet
Minimum parkway width (curb adjacent) 7.5 feet, including curb
Minimum sidewalk width 5 feet (setback 6 inches from property line)
Street Trees
within parkways
One-family dwellings and twin homes on small-lots
A minimum of one street tree (24-inch box) per lot is required to be planted in the parkway along all streets. N/A
Condominium projects Street trees shall be spaced no further apart than 30 feet on center within the parkway. N/A
Tree species should be selected to create a unified image for the street, provide an effective canopy, avoid sidewalk damage and minimize water consumption. N/A
ATTACHMENT NO. 4
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
C.5 Drive-aisles
3 or fewer
dwelling units
Minimum 12 feet wide when the drive-aisle is not required for emergency vehicle access, as determined by the Fire Chief. N/A If the drive-aisle is required for emergency vehicle access, it shall be a
minimum of 20 feet wide.
4 or more
dwelling units Minimum 20 feet wide. 21 foot width provided
All projects
No parking shall be permitted within the minimum required width of a drive-aisle.
Resident parking is provided in enclosed garages and guest parking is provided on-street
A minimum 24-foot vehicle back-up/maneuvering area shall be provided in front of garages, carports or uncovered parking spaces (this may include driveway area, drive-aisles, and streets).
Buildings are setback from the 21 foot wide drive aisle to provide a minimum 24 foot depth for garage access.
Additional width may be required for vehicle/emergency vehicle maneuvering area. N/A
Parkways and/or sidewalks may be required. N/A
No more than 24 dwelling units shall be located along a single-entry drive-aisle. 16 dwelling units are proposed
All drive-aisles shall be enhanced with decorative pavement. A ten foot width of permeable pavers provides a decorative enhancement.
C.6
Number of Visitor
Parking Spaces Required (1)
Projects with 10 units or fewer A .30 space per each unit. Four guest parking spaces are required. Four parallel on-street
parking spaces with a length of 24 feet are provided plus one on-site space is provided.
Projects 11 units or more A .25 space per each unit.
When calculating the required number of visitor parking spaces, if the calculation
results in a fractional parking space, the required number of visitor parking spaces shall always be rounded up to the nearest whole number.
ATTACHMENT NO. 4
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
C.7
Location of Visitor Parking
On Private/ Public Streets
On-street visitor parking is permitted on private/public streets, subject to the following:
The private/public street is a minimum 34-feet wide (curb-to-curb)
There are no restrictions that would prohibit on-street parking where the visitor parking is proposed The visitor parking spaces may be located:
o Along one or both sides of any private/public street(s) located within the project boundary, and
o Along the abutting side and portion of any existing public/private street(s) that is contiguous to the project boundary
Four parallel on-street parking
spaces with a length of 24 feet are provided
In parking bays along public/private streets within the project boundary,
provided the parking bays are outside the minimum required street right-of-way width.
One on-site guest parking space is provided in a parking bay.
When visitor parking is provided as on-street parallel parking, not less than 24 lineal feet per space, exclusive of driveway/drive-aisle entrances and
aprons, shall be provided for each parking space, except where parallel parking spaces are located immediately adjacent to driveway/drive-aisle aprons, then 20 lineal feet may be provided.
Four parallel on-street parking spaces with a length of 24 feet are provided
Within the Beach Area Overlay Zone, on-street parking shall not count toward meeting the visitor parking requirement.
N/A
On Drive-aisles Visitor parking must be provided in parking bays that are located outside the required minimum drive-aisle width.
One on-site guest parking space is provided in a parking bay
On a Driveway
Outside the Beach Area
Overlay Zone
One required visitor parking space may be credited for each driveway in a project that has a depth of 40 feet or more.
N/A
For projects with 10 or fewer units, all required visitor parking may be located within driveways (located in front of a unit’s garage), provided that all dwelling units in the project have driveways with a depth of 20 feet or more.
N/A
Within the Beach Area Overlay Zone
One required visitor parking space may be credited for each driveway in a project that has a depth of 40 feet or more. N/A
If the streets within and/or adjacent to the project allow for on-
street parking on both sides of the street, then visitor parking may be located in a driveway, subject to the following:
All required visitor parking may be located within driveways
(located in front of a unit’s garage), provided that all dwelling units in the project have driveways with a depth of 20 feet or more.
If less than 100% of the driveways in a project have a depth of 20 feet or more, then a .25 visitor parking space will be credited for each driveway in a project that has a
depth of 20 feet or more (calculations resulting in a fractional parking space credit shall always be rounded down to the nearest whole number).
N/A
All
projects
The minimum driveway depth required for visitor parking (20 feet or 40 feet) applies to driveways for front or side-loaded garages, and is measured from the property line, back of
sidewalk, or from the edge of the drive-aisle, whichever is closest to the structure.
N/A
Compact Parking
For projects of more than 25 units, up to 25% of visitor parking may be
provided as compact spaces (8 feet by 15 feet). No overhang is permitted into any required setback area or over sidewalks less than 6 feet wide.
N/A
For all projects within the Beach Area Overlay Zone, up to 55% of the
visitor parking may be provided as compact spaces (8 feet by 15 feet). N/A
Distance
from unit
Visitor parking spaces must be located no more than 300 feet as
measured in a logical walking path from the entrance of the unit it could be considered to serve.
All of the dwelling units are within
300 feet of the guest parking spaces.
ATTACHMENT NO. 4
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
C.8 Screening of Parking
Areas
Open parking areas should be screened from adjacent residences and public rights-of-way by either a view-obscuring wall, landscaped berm, or landscaping, except parking
located within a driveway.
N/A
C.9 Community Recreational Space (1)
Community recreational space shall be provided for all projects of 11 or more dwelling units, as follows: 150 square feet per unit is required for projects in the R-30 land use designation. 2,400 square feet is required and 2,500 square feet is
provided cumulatively in three separate areas onsite
Minimum community recreational space required
Project is NOT within RH general plan designation 200 square feet per unit
Project IS within RH general plan designation 150 square feet per unit
Projects with 11 to 25 dwelling units Community recreational space shall be provided as either (or both) passive or active recreation facilities. Passive is provided
Projects with 26 or more dwelling units
Community recreational space shall be provided as both passive and active recreational facilities with a minimum of 75% of the area allocated for active facilities. N/A
Projects with 50 or more dwelling units
Community recreational space shall be provided as both passive and active recreational facilities for a variety of age groups (a minimum of 75% of the area allocated for active facilities). N/A
For projects consisting of one-family dwellings or twin homes on small-lots, at least 25% of the community recreation space must be provided as pocket parks.
Pocket park lots must have a minimum width of 50 feet and be located at strategic locations such as street intersections (especially “T-intersections”) and where open space vistas may be achieved.
N/A
All projects (with 11 or more
dwelling units)
Community recreational space shall be located and designed so as to be functional, usable, and easily accessible from the units it is intended to serve.
All community areas are easily accessible.
Credit for indoor recreation facilities shall not exceed 25% of the required community recreation area. N/A
Required community recreation areas shall not be located in any required front yard and may not include any streets, drive-aisles, driveways, parking areas, storage areas, slopes of 5% or greater, or walkways (except those walkways that are clearly integral to the design of the recreation area).
Complies
Recreation Area
Parking
In addition to required resident and visitor parking, recreation area parking shall be provided, as follows: 1 space for each 15 residential units, or fraction thereof, for units located more than
1,000 feet from a community recreation area.
N/A
The location of recreation area parking shall be subject to the
same location requirements as for visitor parking, except that required recreation area parking shall not be located within a driveway(s).
N/A
Examples of recreation facilities include, but are not limited to, the following:
Active
Swimming pool area
Children’s playground equipment Spa Courts (tennis, racquetball, volleyball, basketball) Recreation rooms or buildings
Horseshoe pits Pitch and putt Grassy play areas with a slope of less than 5% (minimum area of 5,000 square feet and a minimum dimension of 50 feet) Any other facility deemed by the City Planner to satisfy the intent of providing active recreational
facilities.
ATTACHMENT NO. 4
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
Passive
Benches
Barbecues Community gardens Grassy play areas with a slope of less than 5%.
C.10 Lighting Lighting adequate for pedestrian and vehicular safety shall be provided. Complies
C.11 Reserved
C.12 Recreational Vehicle (RV) Storage (1)
Required for projects with 100 or more units, or a master or specific plan with 100 or more planned development units. Exception: RV storage is not required for projects located within the RMH or RH land use designations.
N/A 20 square feet per unit, not to include area required for driveways and approaches.
Developments located within master plans or residential specific plans may have this
requirement met by the common RV storage area provided by the master plan or residential specific plan.
RV storage areas shall be designed to accommodate recreational vehicles of various sizes (i.e. motorhomes, campers, boats, personal watercraft, etc.). N/A
The storage of recreational vehicles shall be prohibited in the front yard setback and on any public or private streets or any other area visible to the public. A provision containing this restriction shall be included in the covenants, conditions and restrictions for the project. All RV storage areas shall be screened from adjacent residences and public rights-of-way by a view-obscuring wall and landscaping.
N/A
C.13 Storage Space
480 cubic feet of separate storage space per unit. Complies If all storage for each unit is located in one area, the space may be reduced to 392 cubic feet.
Required storage space shall be separately enclosed for each unit and be conveniently accessible to the outdoors. Complies
Required storage space may be designed as an enlargement of a covered parking structure provided it does not extend into the area of the required parking stall, and does not impede the ability to utilize the parking stall (for vehicle parking). Complies
A garage (12’x20’ one-car, 20’x20’ two-car, or larger) satisfies the required storage space per unit.
A garage with minimum interior dimensions of 20 ft. X 20 ft. are
provided.
This requirement is in addition to closets and other indoor storage areas. Complies
(1) This standard does not apply to housing for senior citizens (see Chapter 21.84 of this code).
ATTACHMENT NO. 5
PLANNED DEVELOPMENTS (CMC SECTION 21.45.080)
TABLE E: CONDOMINIUM PROJECTS
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
E.1 Livable Neighborhood Policy
Must comply with city council Policy 66, Principles for the Development of Livable Neighborhoods. SEE SEPARATE COMPLIANCE CHART
E.2 Architectural Requirements
One-family and two-family dwellings
Must comply with city council Policy 44, Neighborhood Architectural Design Guidelines SEE SEPARATE COMPLIANCE CHART
Multiple-family dwellings
There shall be at least three separate building planes on all building elevations. The minimum offset in planes shall be 18 inches and shall include, but not be limited to, building walls, windows, and roofs. Complies
All building elevations shall incorporate a minimum of four complimentary design elements, including but not limited to:
A variety of roof planes;
Windows and doors recessed a minimum of 2 inches;
Decorative window or door frames;
Exposed roof rafter tails;
Dormers;
Columns; Arched elements;
Varied window shapes;
Exterior wood elements; Accent materials such as brick, stone, shingles, wood, or siding;
Knee braces; and
Towers.
A variety of roof planes;
Windows and doors recessed a minimum of 2 inches;
Decorative window or door frames;
Exposed roof rafter tails;
Varied window shapes;
Exterior wood elements; Stone accent materials
E.3 Maximum Coverage 60% of total project net developable acreage. 42%
E.4 Maximum Building Height
Same as required by the underlying zone, and not to exceed three stories (1)(7)
Projects within the RH
general plan designation (1)(7)
40 feet, if roof pitch is 3:12 or greater
33 feet 9 inches maximum height 5:12 roof pitch 35 feet, if roof pitch is less than 3:12
Building height shall not exceed three stories
E.5 Minimum Building Setbacks
From a private or
public street(2)(3)
Residential structure 10 feet
N/A Direct entry garage 20 feet
From a drive-aisle(4)
Residential structure (except as specified below)
5 feet, fully landscaped (walkways providing access to dwelling entryways may be located within required landscaped area) See below for residential over garage
Residential structure –directly above a
garage
0 feet when projecting over the front of a garage. Complies
Garage
3 feet See below for projects within the R-
30 and fewer than 25 units Garages facing directly onto a drive-aisle shall be equipped with an automatic garage door opener.
Projects of 25 units or less within the RMH
and RH general plan designations
0 feet (residential structure and garage) Complies
Garages facing directly onto a drive-aisle shall be equipped with an automatic garage door opener. Complies
Balconies/decks (unenclosed and
uncovered)
0 feet
N/A
May cantilever over a drive-aisle, provided the balcony/deck complies with all other applicable requirements, such as:
Setbacks from property lines
Building separation
Fire and Engineering Department requirements
From the perimeter property lines of the project site (not adjacent to a public/private street)
The building setback from an interior side or rear perimeter property line shall be the same as required by the underlying zone for an interior side or rear yard setback.
Five feet minimum side yard setback required and provided. Minimum 10 foot rear yard setback required and provided.
ATTACHMENT NO. 5
REF
NO
SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
E.6 Minimum Building Separation 10 feet 15 feet minimum between Building “A” and Building “B”
E.7 Resident
Parking (6)
All dwelling types
If a project is located within the RH general plan designation, resident parking shall be provided as specified below, and may also be provided as follows:
25% of the units in the project may include a tandem two-car garage (minimum 12 feet x 40 feet). Calculations for this provision resulting in a fractional unit may be rounded up to the next whole number.
N/A
One-family and two-
family dwellings
2 spaces per unit, provided as either:
a two-car garage (minimum 20 feet x 20 feet), or
2 separate one-car garages (minimum 12 feet x 20 feet each) In the R-W Zone, the 2 required parking spaces may be provided as 1 covered space and 1 uncovered space (5)
N/A
Multiple-family dwellings
Studio and one-bedroom units
1.5 spaces per unit, 1 of which must be covered (5)
N/A When calculating the required number of parking
spaces, if the calculation results in a fractional parking space, the required number of parking spaces shall always be rounded up to the nearest whole number.
Units with two or more bedrooms
2 spaces per unit, provided as either:
a one-car garage (12 feet x 20 feet) and 1 covered
or uncovered space; or (5)
a two-car garage (minimum 20 feet x 20 feet), or
2 separate one-car garages (minimum 12 feet x 20 feet each) In the R-W Zone and the Beach Area Overlay Zone, the 2 required parking spaces may be provided as 1 covered space and 1 uncovered
space (5)
All resident parking is provided in an enclosed two-car garage.
Required parking may be provided within an enclosed parking garage with multiple, open parking spaces, subject to the following:
Each parking space shall maintain a standard stall size of 8.5 feet by 20 feet, exclusive of supporting columns; and
A backup distance of 24 feet shall be maintained in addition to a minimum 5 feet turning bump-out located at the end of any stall series.
N/A
Required resident parking spaces shall be located no more than 150
feet as measured in a logical walking path from the entrance of the units it could be considered to serve.
All resident parking is attached to its
respective dwelling unit
ATTACHMENT NO. 5
REF
NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT
E.8
Private Recreational Space
One-family, two-family, and multiple-
family dwellings
Required private recreational space shall be designed so as to be functional,
usable, and easily accessible from the dwelling it is intended to serve. Complies
Required private recreational space shall be located adjacent to the unit the area is intended to serve. Complies
Required private recreational space shall not be located within any required
front yard setback area, and may not include any driveways, parking areas, storage areas, or common walkways. Complies
One-family
and two-family dwellings
Minimum total area per unit
Projects not within the RMH or RH general plan designations 400 square feet
N/A Projects within the RMH or RH general plan designations 200 square feet
May consist of more than one recreational space. N/A
May be provided at ground level and/or as a deck/balcony on a second/third floor or roof. N/A
If provided at ground level
Minimum dimension
Not within the RMH or RH general plan designations 15 feet N/A Within the RMH or RH general plan designations 10 feet
Shall not have a slope gradient greater than 5%. N/A
Attached solid patio covers and decks/balconies may project into a required private recreational space, subject to the following:
The depth of the projection shall not exceed 6 feet (measured from the wall of the dwelling that is contiguous to the patio/deck/balcony). The length of the projection shall not be limited, except as required by any setback or lot coverage standards.
N/A
Open or lattice-top patio covers may be located within the required private recreation space (provided the patio cover
complies with all applicable standards, including the required setbacks).
N/A
If provided above ground level as a deck/ balcony or roof deck
Minimum dimension 6 feet
N/A
Minimum area 60 square feet
Multiple-family dwellings
Minimum total area per unit (patio, porch, or balcony) 60 square feet Complies
Minimum dimension of patio, porch or balcony 6 feet Complies
Projects of 11 or more units that are within the RH general plan designation may opt to provide an additional 75 square feet of community recreation
space per unit (subject to the standards specified in Table C of this Chapter), in lieu of providing the per unit private recreational space specified above.
N/A
(1) If a project is located within the Beach Area Overlay Zone, building height shall be subject to the requirements of Chapter 21.82 of this code. (2) See Table C in Section 21.45.060 for required setbacks from an arterial street. (3) Building setbacks shall be measured from the outside edge of the required street right-of-way width, whichever is
closest to the building.
(4) Building setbacks shall be measured from one of the following (whichever is closest to the building): a) the outside edge of the required drive-aisle width; b) the back of sidewalk; or c) the nearest side of a parking bay located contiguous to a drive-aisle (excluding parking located in a driveway in front of a unit’s garage). (5) Any uncovered required parking space in the R-W zone may be located within a required front yard setback and may
be tandem. (6) This standard does not apply to housing for senior citizens (see Chapter 21.84 of this code). (7) Protrusions above the height limit shall be allowed pursuant to Section 21.46.020 of this code. Such protrusions include protective barriers for balconies and roof decks.
ATTACHMENT NO. 6
CITY COUNCIL POLICY 66 – LIVABLE NEIGHBORHOODS
Principle Compliance Comments
1 Building Facades, Front Entries, Porches
Facades create interest and character and should be varied and
articulated to provide visual interest to pedestrians. Clearly
identifiable front doors and porches enhance the street scene
and create opportunities for greater social interaction within the
neighborhood. Building entries and windows should face the
street. Front porches, bay windows, courtyards and balconies
are encouraged.
The project was designed with a focus on
the elevations facing Magnolia Avenue.
Front doors and porches face the street.
Varied building planes on these building
elevations create visual interest.
2 Garages
Homes should be designed to feature the residence as the
prominent part of the structure in relation to the street. A
variety of garage configurations should be used to improve the
street scene. This may include tandem garages, side-loaded
garages, front-loaded garages, alley-loaded garages and recessed
garages.
Garages are “side-loaded” and do not
therefore dominate the street scape.
3 Street Design
An interconnected, modified (grid) street pattern should be
incorporated into project designs when there are no topographic
or environmental constraints. Interconnected streets provide
pedestrians and automobiles many alternative routes to follow,
disperse traffic and reduce the volume of cars on any one street
in the neighborhood. Streets should be designed to provide both
vehicular and pedestrian connectivity by minimizing the use of
cul-de-sacs.
The street network should also be designed to create a safer,
more comfortable pedestrian and bicycling environment. Local
residential streets should have travel and parking lanes, be
sufficiently narrow to slow traffic, provide adequate access for
emergency and service vehicles and emergency evacuation
routes for residents and include parkways with trees to form a
pleasing canopy over the street. Local residential streets are the
public open space in which children often play and around which
neighborhoods interact. Within this context, vehicular
movement should be additionally influenced through the use of
City-accepted designs for traffic calming measures.
N/A
4 Parkways
Street trees should be planted in the parkways along all streets.
Tree species should be selected to create a unified image for the
street, provide an effective canopy, avoid sidewalk damage and
minimize water consumption.
Magnolia Street has curb adjacent
sidewalks. The parkway adjacent to the
sidewalk will be landscaped and
maintained by the project.
ATTACHMENT NO. 6
Principle Compliance Comments
5 Pedestrian Walkways
Pedestrian walkways should be located along or visible from all
streets. Walkways (sidewalks or trails) should provide clear,
comfortable and direct access to neighborhood schools,
parks/plazas and transit stops. Primary pedestrian routes should
be bordered by residential fronts, parks or plazas. Where street
connections are not feasible (at the end of cul-de-sacs),
pedestrian paths should also be provided.
Public sidewalks are provided adjacent
to Magnolia Avenue and on-site
pedestrian paths are provided for access
into the site and to individual units.
6 Centralized Community Recreation Areas
Park or plazas, which serve as neighborhood meeting places and
as recreational activity centers should be incorporated into all
planned unit developments. As frequently as possible, these
parks/plazas should be designed for both active and passive uses
for residents of all ages and should be centrally located within
the project. Parks and plazas should be not be sited on residual
parcels, used as buffers from surrounding developments or to
separate buildings from streets.
2,500 square feet of centralized
community recreation is provided onsite.
Planning Commission
Planning Division
lAW OFFICES
HALL & BAILEY
25014 Las Brisas Road South, Suite B
Murrieta, California 92562
Telephone: (951) 304-7566
Facsimile: (951) 304-7571
< July 9, 2015
ATTACHMENT NO. 7
City of Carlsbad
JUL l 3 2015
PlanninG Division
1635 Faraday Avenue
Carlsbad, California 92008 Via u.s. mail
Traffic Safety Commission
City of Carlsbad
Attn: John Kim
Via email at
John.Kim@Car1sbadca.gov
Re: Project Reference: CT 14-05 Magnolia Townhomes
749 and 763 Magnolia Avenue, Carlsbad, California
Dear Mr. Kim and Commission:
My wife and I own a home across the street from the above-
referenced project. It is our understanding that the project calls
for the construction of 16 townhouses on the properties located at
749 and 763 Magnolia Avenue, Carlsbad, California (the •Project") .
From my communications with Christer Westman, Sr. Planner, it
is my understanding that the Project calls for attached two-car
garages for each of the 16 townhouses, and one guest (handicapped
accessible) parking space located on-site, together with enough
street frontage on Magnolia to allegedly accommodate four
additional parking spaces needed for the Project.
The purpose of this correspondence is to express our concern
about the parking allocated for this Project. Although Mr. Westman
has indicated that the Project is Code compliant for the spaces
allocated, it is our concern that this Project will impose a
significant and heavy burden on the street parking.
Over the past approximately five years, the street parking in
the area has become more and more congested. There is not
sufficient street parking available for the existing residences on
Magnolia Avenue.
<
Planning Commission
Planning Division
lAW OFFICES
HALL & BAILEY
25014 Las Brisas Road South, Suite B
Murrieta, California 92562
Telephone: (951) 304-7566
Facsimile: (951) 304-7571
July 14, 2015
ATTACHMENT NO.8
City of Carlsbad
JUL 1 7 2015
Planning Division
1635 Faraday Avenue
Carlsbad, California 92008 Via U.S. mail
Traffic Safety Commission
City of Carlsbad
Attn: John Kim
Via email at
John.Kim@Carlsbadca.gov
Re: Project Reference: CT 14-05 Magnolia Townhomes
749 and 763 Magnolia Avenue, Carlsbad, California
Planning Commission Meeting: August 5, 2015
Dear Mr. Kim and Commission:
On July 14, 2015, I had a telephone conversation with Tony
Sfreddo, who I understand to be the contact for the owner/developer
of the above Project.
During our conversation, Mr. Sfreddo indicated to me that he
could not place an additional four parking spaces on the Project
site. Mr. Sfreddo stated that, at the most, he could possibly add
one more parking space onto the Project site, only if the City
would waive the landscaping requirements.
Mr. Sfreddo also stated that he initially proposed the Project
to the City as a 14-unit Project, but was informed that there
needed to be at least 17 to 19 units on the site. After working
with the City further, it was ultimately agreed that 16 units would
be sufficient for this new Project development. I would think that
if the site was reduced to 14 units, all visitor parking could be
placed on the Project site.
Mr. Sfreddo also indicated to me that his current "footprint"
for all the buildings on the Project covers approximately 42% of
the total Project site, and he is allowed up to 60%.
Notwithstanding the smaller "footprint," Mr. Sfreddo made it clear
to me that he could not accommodate any additional parking spaces
on the Project site, except for possibly one as indicated above.
A-1.1Conceptual Site Plan
Magnolia Townhomes749 Magnolia Ave
Carlsbad, CA
16-unit
Condominium
7/10/15
BEGOVICH + HAUG ARCHITECTS
begovich-haug.com
562-988-1174
DS PRODUCTS, INC.
scale: 3/32"=1'-0"
Lots 5 & 26
Property line dimensions based on Owner parcel map
Architect assumes no responsibility for its accuracy
0 5 10 20 ft.
An accessible (4ft. wide) path of travel connecting at least one
accessible entrance of each covered multifamily dwelling unit with
exterior spaces & facilities that serve the dwelling unit
Path shall meet the following:
1. max 5% slope in direction of travel
2. max 2% cross slope
3. max 2% at change of direction, loading aisles & landings
Community recreation area
Plan 1 (2-bed rm): 5-units @1,092 sq.ft. = 5,460 sq.ft.
Unit Floor Area:
Plan 2 (2-bed rm): 4-units @1,120 sq.ft. = 4,480 sq.ft.
Plan 3 (3-bed rm): 7-units @1,565 sq.ft. = 10,955 sq.ft.
Total living area: 16-units 20,895 sq.ft.
Maximum Lot Coverage Allowed:
Lot coverage Proposed:
17,827 sq.ft. = 60%
12,425 sq.ft. = 42%
General Plan: Existing RMH & Proposed R-30, Existing 8-15 units/ac & Proposed 23-30 units/ac
Growth Management Control Point of Existing 12 units/ac & Proposed 25 units/ac
Zoning: RD-M Residential Density-Multiple
Site Area: 29,712 sq.ft. (.68 acre)
Density Allowed: 23-30 units/acre
Density Proposed: 23.5 units/acre (16-units)
Private Patio Area Required: 60 sf/unit (min)
Private Patio Area Proposed: 105-335 sf/unit (min)
Community Rec. Space Required: 200 sf/unit = 3,200 sq.ft.
Community Rec. Space Proposed: 226 sf/unit = 3,617 sq.ft.
0.25 guest spaces/unit
Total spaces required
Parking required:
2.0 spaces/2-bdrm unit x 9 = 24.0 spaces
= 4.0 spaces
= 36.0 spaces
owner/developer:
DS PRODUCTS, INC.
24 AMBERLEAF
IRVINE, CA 92614
951.801.0888
architect:
BEGOVICH+HAUG ARCHITECTS
3450 E. SPRING ST. #118
LONG BEACH, CA 90806
562.988.1174
civil engineer:
DMS CONSULTANTS
12377 LEWIS ST. #101
GARDEN GROVE, CA 92840
714.740.8840
landscape design:
GARCIA LANDSCAPE
1918 KEMPER AVE
SANTA ANA, CA 92705
714.538.6000
general information
project data
Coastal Development Permit
application types
Planned Development Permit
Tentative Tract Map Legal Description: That portion of Tract No.231, Thum Lands in the City of Carlsbad, County of
San Diego, State of CA, according to map thereof #1681, filed in the office of the County Recorder
of San Diego County, December 9, 1915, described as follows:
Beginning at the Northeast corner of said Tract 231, said point being also the intersection of the
Southerly line of Magnolia Ave with the Westerly line of Jefferson St., thence North 89 deg. 26'
West along the Southerly line of Magnolia Ave, a distance of 157.59 ft. to the True Point of
Beginning; thence South 28 deg. 39' East 275.93 ft.; thence South 61 deg. 21' West 65.00 ft.;
thence North 28 deg. 39' West 312.38 ft.; to the Southerly line of Magnolia Ave; thence South
89 deg. 26' East; along Magnolia Ave 74.47 ft.; to the True Point of Beginning.
APN: 204-280-26-00
Proposed Land Use: 16-Townhome Condominium units
Landscape Area: 7,408 sq.ft. (25%)
Sewer/Water: Carlsbad Municipal Water District
School: Carlsbad Unified School District
Building A: 10,955 sq.ft. (living) + 2,800 sq.ft. (garage) = 13,755 sq.ft.
Building Floor Area:
Building B: 4,480 sq.ft. (living) + 1,808 sq.ft. (garage) = 6,288 sq.ft.
Building C: 5,460 sq.ft. (living) + 2,100 sq.ft. (garage) = 7,560 sq.ft.
Total building area: 27,603 sq.ft.
Fire sprinklers: All units require sprinklers designed to NFPA 13 standards
2.0 garage spaces/unit = 32.0 spaces
on-site open spaces = 1.0 spaces
Parking provided:
Total spaces provided = 37.0 spaces
on-street open spaces = 4.0 spaces
2.0 spaces/3-bdrm unit x 7 = 14.0 spaces
5 FWY
Jefferson St.
Garfield St.Tamarack Averailroad tracks
PROJECT
SITE
northHibiscus CircleMagnolia Avevicinity map (nts)Anchor Wayrevision#1: 12/19/201412'-0"17'-0"2'5'-0"19'-0"5'-0"19'-0"5'-0"7'-1"18'-0"18'-4"30'-0"24'-0"25'-6"25'-6"fire dept.access drive20' wideopen to sky20'-0"9'-0"6'-10"4'13'-11"24'-0"35'-0"5'-6"24'-6"6'-0"7'-6"10'-6"39'-4"19'-6"9'-0"8'-0"103'-8"28'-6 1
2"
147'-6"36'-4"36'-4"18"13'-6"12'-0"36'-4"13'-6"7'-6"36'-4"12'-0"18"24'-0"22'-6"39'-4"18"39'-4"19'-3"6'-0"6'-0"12'-3"25'-6"fire dept.access drive20' wideopen to sky20'-0"6'-0"13'-3"14'-11"98'-11"10'-0"24'-0"3'-3"5'-0"19'-0"5'-0"19'-0"5'-0"11'-9"6'-6"4'-6"18'-0"
2-car garage
20'x20'
2-car garage
20'x20'
2-car garage
20'x20'
2-car garage
20'x20'
2-car garage
20'x20'
2-car garage
20'x20'
2-car garage
20'x20'
2-car garage
20'x20'
2-car garage
20'x20'2-car garage
20'x20'
2-car garage
20'x20'
Unit #3
Plan 3:3-bdr
1,565 sf
Unit #4
Plan 3:3-bdr
1,565 sf
Unit #2
Plan 3:3-bdr
1,565 sf
Unit #5
Plan 3:3-bdr
1,565 sf
Unit #1
Plan 3:3-bdr
1,565 sf
Unit #6
Plan 3:3-bdr
1,565 sf
Unit #7
Plan 3:3-bdr
1,565 sf
Unit #8
Plan 2:2-bdr
1,120 sf
Unit #11
Plan 2:2-bdr
1,120 sf
Unit #9
Plan 2:2-bdr
1,120 sf
Unit #10
Plan 2:2-bdr
1,120 sf
property line 312.30' N28°39'00"W property line 65.00' N61°19'45"Eproperty line 151.70' S88°26'00"EMagnolia Ave10' min.setback linelandscape
2
3 10' min.setback lineproperty line 138.45' N28°39'00"W
2-car garage
20'x20'
2-car garage
20'x20'
2-car garage
20'x20'
2-car garage
20'x20'
2-car garage
20'x20'
Unit #12
Plan 1:2-bdr
1,092 sf
Unit #15
Plan 1:2-bdr
1,092 sf
Unit #16
Plan 1:2-bdr
1,092 sf
Unit #13
Plan 1:2-bdr
1,092 sf
Unit #14
Plan 1:2-bdr
1,092 sf
2nd floor
projection
4
5
Bldg. A
3-story
Bldg. B
2-story
Bldg. C
2-story
1
van
accessible
loading
aisle
accessible
parking stall
9'x19'
refuse bin
enclosure
6' high blk.
wall w/gates
fire dept.
turnaround
no parking
HCD accessible
adaptable unit
4' conc. walk 4' conc. walk
2nd floor
arch.
projection
private
patio
135 sf
private
patio
135 sf
private
patio
135 sf
private
patio
335 sf2nd floor
arch.projection
2nd floor
arch.projection
driveway w/
eco-stone
pavers
new 6' high
block wall
new 6' high
block wall
new 6' high
block wall
new 6' high
block wall
new 6' high
block wallproperty line 67.41' N61°19'45"Eprivate
patio
105 sf
private
patio
105 sf
private
patio
105 sf
private
patio
105 sf
private
patio
105 sf
4' conc. walk
4' conc. walk
2nd floor
projection
driveway w/
eco-stone
pavers
new 6' high
block wall
private
patio
105 sf
private
patio
105 sf
private
patio
105 sf
private
patio
105 sf
private
patio
105 sf community
rec. area
2,870 sq.ft.
passive grassy
play area
private
patio
105 sf
private
patio
105 sf
4' conc. walk
2nd floor
projection
HCD accessible
adaptable unit
community
rec. area
280 sq.ft.
passive
grassy
play area
community
rec. area
467 sq.ft.
passive
grassy
play area
4' conc. walk
4' con
c
.
w
a
l
k4' conc. walk4' conc. walkpassive grassy
play area
entry
porch
entry
porch
entry
porch entry
porch
entry
porch
entry
porch
entry
porch
entry
porch
entry
porchentry
porch
2nd floor
projection
planter planter planter
planter
planterplanter2nd floor
projection
planter
planter planter
2nd floor
projection
2nd floor
projection
2nd floor
arch.
projection
2nd floor
projection
entry
porch
entry
porch entry
porch
4' conc. walk
3rd floor
projection
planter
property line 99.80' N28°39'00"W
recycl
e
bin
trash
bin
A-1.2Roof Plans (rev)
Magnolia Townhomes749 Magnolia Ave!
Carlsbad, CA
16-unit!
Condominium
12/18/14
BEGOVICH + HAUG ARCHITECTS
begovich-haug.com
562-988-1174
DS PRODUCTS, INC.
scale: 1/8"=1'-0"0 5 revision#1: 12/19/2014valley flshgridge
valley flshg5:12!slope5:12!sloperidge5:12!
slope
ridgeridge
hipvalley flshgridgevalley flshg5:12!
slope
5:12!
slope
5:12!slope5:12!slope5:12!slope5:12!
slope
5:12!
slope
ridge
ridge ridge
valley flshgvalley flshgvalley flshg5:12!slope5:12!slope5:12!slope5:12!sloperidgeridgeridgeridge5:12!
slope
5:12!
slope
5:12!
slope
5:12!
slope
ridgeridgeridgeridgehiphipvalley flshgvalley flshgvalley flshgvalley flshgridgeridgeridgeridgevalley flshgvalley flshgvalley flshgvalley flshg5:12!
slope
5:12!
slope
5:12!
slope
5:12!
slope
5:12!
slope
5:12!
slope
5:12!slope5:12!slope5:12!slope5:12!slope5:12!slope5:12!slope5:12!slope5:12!slope5:12!
slope
5:12!
slope
5:12!
slope
5:12!
slope5:12!
slope
5:12!
slope
5:12!
slope
5:12!
slope
ridge ridgeridgeridge
valley flshgvalley flshgvalley flshgvalley flshgvalley flshgvalley flshg5:12!slope5:12!slope5:12!slope5:12!sloperidgeridgeBldg. C: Roof planridgeridge5:12!slopehipvalley flshg5:12!slope5:12!sloperidge
5:12!
slopehip5:12!slope10 ft.
ridge ridgeridge ridgevalley flshgvalley flshgvalley flshgvalley flshgvalley flshgvalley flshgvalley flshgvalley flshgvalley flshgvalley flshgvalley flshgvalley flshgvalley flshgvalley flshgvalley flshgvalley flshgridgeridgeridgeridgeridgeridgeridgeridge ridge5:12!slope5:12!slope5:12!slope5:12!slope5:12!slope5:12!slope5:12!slope5:12!slope5:12!slope5:12!slope5:12!slope5:12!
slope
5:12!
slope
5:12!
slope
5:12!
slope
5:12!
slope
5:12!
slope
5:12!
slope
5:12!
slope
5:12!
slope
5:12!
slope
5:12!
slope
5:12!
slope
ridgeridge5:12!
slope
5:12!
slope
5:12!
slope
5:12!
slope
Bldg. B: Roof plan
Bldg. A: Roof plan 5:12!slope5:12!slopevalleyhip5:12!
sloperidge5:12!
slope
5:12!
slope5:12!slope5:12!
slope
5:12!slope5:12!slope
5:12!
slope
5:12!slope
5:12!
slope
5:12!slope5:12!slope
ridgeridge
ridgehip
hipvalleyridge valleyvalleyvalleyvalleyridgevalleyhip5:12!slope5:12!slopevalleyhip5:12!
slope ridge5:12!
slope
5:12!
slope 5:12!slope5:12!
slope5:12!slope5:12!
slope
5:12!
slope
5:12!
slope
5:12!slope
5:12!slope5:12!
slope
ridgeridge
ridgehip
hipvalleyridgevalleyvalleyvalley
valleyridgevalleyhip5:12!slope5:12!slopevalleyhip5:12!
slope ridge5:12!
slope
5:12!
slope 5:12!slope5:12!
slope
5:12!slope5:12!
slope
5:12!
slope
5:12!
slope
5:12!slope
5:12!slope5:12!
slope
ridgeridge
ridgehip
hipvalleyridgevalleyvalleyvalley
valleyridgevalleyhip5:12!slope5:12!slopevalleyhip5:12!
sloperidge5:12!slope
5:12!
slope5:12!slope5:12!
slope
5:12!slope5:12!slope
5:12!
slope
5:12!slope
5:12!
slope
5:12!slope5:12!slope
ridgeridge
ridgehip
hipvalleyridge valleyvalleyvalleyvalleyridgevalleyhip5:12!slope5:12!slopevalley5:12!
slope ridge5:12!
slope
5:12!
slope 5:12!slope5:12!slope5:12!
slope
5:12!slope
5:12!
slope
5:12!slope5:12!slope
ridgeridge
ridgehip
hipvalleyvalleyvalleyvalleyridgevalleyhip5:12!slope5:12!slopevalleyhip5:12!
slope ridge5:12!
slope
5:12!
slope 5:12!slope5:12!
slope
5:12!slope5:12!slope
5:12!
slope
5:12!slope
5:12!
slope
5:12!slope5:12!slope
ridgeridge
ridgehip
hipvalleyridgevalleyvalleyvalley
valleyridgevalleyhip5:12!slope5:12!slopevalleyhip5:12!
sloperidge5:12!
slope
5:12!
slope5:12!slope5:12!
slope
5:12!slope5:12!
slope
5:12!
slope
5:12!
slope
5:12!slope
5:12!slope5:12!
slope
ridgeridge
ridgehip
hipvalleyridge valleyvalleyvalleyvalleyridgevalleyhipridgevalley5:12!slope
5:12!slope
A-2.1Bldg. A Floor Plans
Magnolia Townhomes749 Magnolia Ave!
Carlsbad, CA
16-unit!
Condominium
12/19/14
BEGOVICH + HAUG ARCHITECTS
begovich-haug.com
562-988-1174
DS PRODUCTS, INC.
scale: 3/16"=1'-0"0 5 10 ft.revision#1: 12/19/2014
twh
twh twh
twh
twhtwh
twh 1'-6"21'-0"1"21'-0"1"21'-0"1"21'-0"1"21'-0"1"21'-0"1"21'-0"
147'-6"
21'-0"1"21'-0"1"21'-0"1"21'-0"1"21'-0"1"21'-0"1"21'-0"
147'-6"5'-0"1'-6"5'-4"31'-0"1'-6"37'-10"1'-6"34'-0"1'-6"39'-4"34'-10"2'-4"1'-6"1'-6"5'-0"12"12'-6"13'-2"8'-4"3'-0"5'-4"4'-2"25'-4"1'-6"1'-6"1'-6"5'-0"4'-6"7'-0"14'-0"1"13'-6"7"4'-2"7"4'-5"7"4'-2"7"13'-6"1"13'-6"7"4'-2"7"4'-5"7"4'-2"7"13'-6"1"13'-6"7"4'-2"7"4'-5"7"4'-2"7"13'-6"12"34'-10"3'-0"5'-4"4'-2"25'-4"5'-0"4'-6"7'-0"14'-0"1"13'-6"7"4'-2"7"4'-5"7"4'-2"7"13'-6"1"13'-6"7"4'-2"7"4'-5"7"4'-2"7"13'-6"1"13'-6"7"4'-2"7"4'-5"7"4'-2"7"13'-6"12"
up
up
up
up
bath
bath
bath bath
bath
bath
bath
den/office!
10'0"x11'0"
den/office!
10'0"x11'0"den/office!
10'0"x11'0"
den/office!
10'0"x11'0"
den/office!
10'0"x11'0"den/office!
10'0"x11'0"
den/office!
10'0"x11'0"
2-car garage!
20'0"x20"0"
2-car garage!
20'0"x20"0"2-car garage!
20'0"x20"0"
2-car garage!
20'0"x20"0"
2-car garage!
20'0"x20"0"2-car garage!
20'0"x20"0"
2-car garage!
20'0"x20"0"
closet
closet
closet closet
closet
closet
closet
unit #7!
plan 3
unit #4!
plan 3unit #3!
plan 3
unit #6!
plan 3
unit #5!
plan 3unit #2!
plan 3
unit #1!
plan 3 up
up
up up
up
up
up
Second Floor Plan
First Floor Plan
linen
linen
linen linen
linen
linen
linen
dw
dw
dw dw
dw
dw
dw
refrigrefrigrefrigrefrigrefrigrefrigrefrigpantrypantrypantrypantrypantrypantrypantrydndn
dndn
dndn
dn
up
up
up up
up
up
up
dn
dn
dn dn
dn
dn
dn
linen
linen
linen linen
linen
linen
linen
kitchen!
9'9"x11'6"
kitchen!
9'9"x11'6"kitchen!
9'9"x11'6"
kitchen!
9'9"x11'6"
kitchen!
9'9"x11'6"kitchen!
9'9"x11'6"
kitchen!
9'9"x11'6"
dining!
9'6"x11'0"
dining!
9'6"x11'0"dining!
9'6"x11'0"
dining!
9'6"x11'0"
dining!
9'6"x11'0"dining!
9'6"x11'0"
dining!
9'6"x11'0"
living!
13'4"x14'0"
living!
13'4"x14'0"living!
13'4"x14'0"
living!
13'4"x14'0"
living!
13'4"x14'0"living!
13'4"x14'0"
living!
13'4"x14'0"
bedroom 3!
10'2"x12'0"
bedroom 3!
10'2"x12'0"bedroom 3!
10'2"x12'0"
bedroom 3!
10'2"x12'0"
bedroom 3!
10'2"x12'0"bedroom 3!
10'2"x12'0"
bedroom 3!
10'2"x12'0"
bath
bath
bath bath
bath
bath
bath
entry
entry
entry entry
entry
entry
entry
unit #7!
plan 3
unit #4!
plan 3unit #3!
plan 3
unit #6!
plan 3
unit #5!
plan 3unit #2!
plan 3
unit #1!
plan 3
range!
micro
range!
micro
range!
micro
range!
micro
range!
micro
range!
micro
range!
micro
entry!
porch
entry!
porchentry!
porch
entry!
porch
dndn
entry!
porch dndn
entry!
porch
entry!
porch
dndn
up
up
up
A-2.2Bldg. A Floor Plans
Magnolia Townhomes749 Magnolia Ave!
Carlsbad, CA
16-unit!
Condominium
12/19/14
BEGOVICH + HAUG ARCHITECTS
begovich-haug.com
562-988-1174
DS PRODUCTS, INC.
scale: 3/16"=1'-0"0 5 10 ft.revision#1: 12/19/2014
attic!
fau
attic!
fau
attic!
fau
attic!
fau
attic!
fau
attic!
fau
attic!
fau
14'-0"14'-0"14'-0"14'-1"14'-1"14'-1"7'-0"14'-0"14'-0"14'-0"14'-0"2'-4"23'-4"37'-10"147'-6"8'-4"1'-4"31'-2"2'-4"1'-8"21'-0"1"21'-0"1"21'-0"1"21'-0"1"21'-0"1"21'-0"1"21'-0"12"3'-10"1'-4"dn
dn
dn dn
dn
dn
dn
linen
linen
linen linen
linen
linen
linen
m.bedroom!
12'8"x13'4"
m.bedroom!
12'8"x13'4"m.bedroom!
12'8"x13'4"
m.bedroom!
12'8"x13'4"
m.bedroom!
12'8"x13'4"m.bedroom!
12'8"x13'4"
m.bedroom!
12'8"x13'4"
bedroom 2!
10'2"x11'6"
bedroom 2!
10'2"x11'6"bedroom 2!
10'2"x11'6"
bedroom 2!
10'2"x11'6"
bedroom 2!
10'2"x11'6"bedroom 2!
10'2"x11'6"
bedroom 2!
11'6"x11'6"
bath
bath
bath bath
bath
bath
bath
unit #7!
plan 3
unit #4!
plan 3unit #3!
plan 3
unit #6!
plan 3
unit #5!
plan 3unit #2!
plan 3
unit #1!
plan 3
m.bath
m.bath
m.bath m.bath
m.bath
m.bath
m.bath washer
washer
washer washer
washer
washer
washer
dryer
dryer
dryer dryer
dryer
dryer
dryer
Third Floor Plan
A-2.3Bldg. A Elevations
Magnolia Townhomes749 Magnolia Ave!
Carlsbad, CA
16-unit!
Condominium
12/19/14
BEGOVICH + HAUG ARCHITECTS
begovich-haug.com
562-988-1174
DS PRODUCTS, INC.
scale: 3/16"=1'-0"0 5 10 ft.revision#1: 12/19/20146"8'-1"9'-1"8'-7"top of slab
top plate
top plate
2nd floor
finish grade
top plate
3rd floor 6"8'-1"9'-1"8'-7"top of slab
top plate
top plate
2nd floor
top plate
3rd floor
finish grade6"8'-1"9'-1"8'-7"top of slab
top plate
top plate
2nd floor
top plate
3rd floor
finish grade 6"8'-1"9'-1"8'-7"top of slab
top plate
top plate
2nd floor
top plate
3rd floor
finish grade6"8'-1"9'-1"8'-7"top of slab
top plate
top plate
2nd floor
top plate
3rd floor
finish grade 33'-9"roof peak
3'-8"8'-4"15'-2" plt. ht.plaster foam!
trim w/keystonevynil slider doors!
w/temp. glass
Sideyard!
(West)!
Elevation
42" high!
wood!
guardrail
stone!
veneer
exterior!
plaster
2x6 wood!
rafters
4'0" high!
plaster!
patio wall
mission style!
conc. roofing
vinyl window!
w/plaster!
foam trim
deco. plaster!
plant-shelf
vinyl window!
w/plaster!
foam trim
6x6!
wood!
post
mission style!
conc. roofing
2x6 wood!
rafters
entry!
steps
deco.!
wood!
corbel
roll-up!
garage!
door
vinyl window!
w/plaster!
foam trim
plaster!
foam trim
deco. plaster!
plant-shelf
painted!
downspout
4'0" high!
plaster!
patio wall
stone!
veneer
exterior!
plaster
2x6 wood!
rafters
mission style!
conc. roofing
vinyl window!
w/plaster!
foam trim
plaster foam trim
stone veneer
exterior plaster
2x6 wood!
rafters
mission style!
conc. roofing
vinyl window!
w/plaster!
foam trim
plaster foam trim
deco.!
wood!
corbel
vinyl window!
w/plaster!
foam trim
stone veneer
exterior!
plaster
2x6 wood!
rafters
mission style!
conc. roofing
vinyl window w/!
plaster foam trim
plaster foam trim
Driveway!
(East)!
Elevation
Magnolia Ave!
(North)!
Elevation
End!
(South)!
Elevation
42" high!
wood!
guardrail
entry!
steps
deco. entry door
4'0" high!
plaster!
patio wall
2x6 wood!
rafters
mission style!
conc. roofing
6x6 wood post
mission style!
conc. roofing
deco!
entry door
entry!
steps plaster!
foam!
trim
stone!
veneer
stone!
veneer
A-3.1Bldg. B Floor Plans
Magnolia Townhomes749 Magnolia Ave!
Carlsbad, CA
16-unit!
Condominium
BEGOVICH + HAUG ARCHITECTS
begovich-haug.com
562-988-1174
DS PRODUCTS, INC.
scale: 3/16"=1'-0"0 5 10 ft.
4/10/14
revision#1: 12/19/2014
attic!
fau
attic!
fau
attic!
fau
attic!
fau
twh twhtwhtwh
24'-8"1"24'-8"1"24'-8"1"24'-8"
98'-11"1'-6"1'-4"25'-2"8'-6"3'-0"35'-0"24'-8"1"24'-8"1"24'-8"1"24'-8"
98'-11"25'-2"8'-6"39'-6"2'-10"3'-0"12"12"
4'-0"4'-0"6'-0"6'-0"6'-0"6'-0"14'-8"14'-8"14'-8"14'-8"2'-0 1
2"4'-0"2'-0 1
2"
4'-0"20'-8"1"20'-8"8'-1"20'-8"1"20'-8"4'-0"
2'-0 1
2"4'-0"2'-0 1
2"
kitchen!
9'6"x12'0"
kitchen!
9'6"x12'0"
kitchen!
9'6"x12'0"
kitchen!
9'6"x12'0"
dining!
10'0"x11'0"
dining!
10'0"x11'0"
dining!
10'0"x11'0"
dining!
10'0"x11'0"
living!
13'0"x14'0"
living!
13'0"x14'0"
living!
13'0"x14'0"
living!
13'0"x14'0"
m.bedroom!
12'0"x12'6"
m.bedroom!
12'0"x12'6"
m.bedroom!
12'0"x12'6"
m.bedroom!
12'0"x12'6"
bath bathbath bath
deck!
5'0"x6'0"
deck!
5'0"x6'0"
refrigrefrig refrigrefrigpantrypantry pantrypantry
dwdw dwdw
entry!
porch
entry!
porch
entry!
porch
linen linenlinen linen
entry entryentry entry
unit #10!
plan 2
unit #9!
plan 2
unit #11!
plan 2
unit #8!
plan 2
deck!
5'0"x6'0"
deck!
5'0"x6'0"
range!
micro
range!
micro
range!
micro
range!
micro
dn dndn
dndn dndn
upup upup
bathbathbathbathbedroom 2!
11'6"x12'0"
bedroom 2!
11'6"x12'0"
bedroom 2!
11'6"x12'0"
bedroom 2!
11'6"x12'0"washerwasherwasherwasher
dryerdryerdryerdryer
2-car garage!
20'0"x20"0"!
452 sf
2-car garage!
20'0"x20"0"!
452 sf
2-car garage!
20'0"x20"0"!
452 sf
2-car garage!
20'0"x20"0"!
452 sf
linenlinenlinenlinen
storage storagestoragestorage
unit #10!
plan 2
unit #9!
plan 2
unit #11!
plan 2
unit #8!
plan 2
stair!
above
stair!
above
stair!
above
stair!
above
upup upup
up up
Second Floor Plan
First Floor Plan
up
A-3.2Bldg. B Elevations
Magnolia Townhomes749 Magnolia Ave!
Carlsbad, CA
16-unit!
Condominium
BEGOVICH + HAUG ARCHITECTS
begovich-haug.com
562-988-1174
DS PRODUCTS, INC.
scale: 3/16"=1'-0"0 5 10 ft.revision#1: 12/19/2014
4/10/14
deco. door!
w/transom!
window
exterior!
plasterexterior!
plaster
2x6 wood!
rafters2x6 wood!
rafters
mission style!
conc. roofingmission style!
conc. roofing
vinyl window!
w/plaster!
foam trim
wood!guardrailwood!
guardrail
stone!
veneer
plaster!
foam trim
Rear yard (Southeast) Elevation Side (Northwest) Elevation
Sideyard (Southwest) Elevation
exterior!
plaster
2x6 wood!
rafters
french door!
w/plaster!
foam trim
inset!
vinyl!
window
painted!
downspout
exterior!
plasterexterior!
plaster
2x6 wood!
rafters
2x6 wood!
rafters
roll-up!
garage!
door
vinyl slider!
w/plaster!
foam trim
stone!
veneer
stone!
veneer
plaster!
foam trim
mission!
style!
conc.!
roofing
inset!
vinyl!
window
wrought iron!
rail@deco.!
plaster!
plant-shelf
painted!
downspout
Driveway Elevation
42" high!
wood!
guardrail
6' high!
plaster wall
deco plaster!
foam corbel
entry stairs!
w/wood!
guardrail
vinyl window!
w/plaster!
foam trim
stone!
veneer
plaster!
foam trim
6' high!
plaster wall
deco plaster!
foam corbel
entry stairs!
w/wood!
guardrail
deco plaster!
foam corbel
vinyl window!
w/plaster!
foam trim
covered entry!
deck w/stairs
42" high!
wood!
guardrail
plaster!
foam trim
mission!
style!
conc.!
roofing
deco plaster!
foam corbel
mission!
style!
conc.!
roofing
A-4.1Bldg. C Floor Plans
Magnolia Townhomes749 Magnolia Ave!
Carlsbad, CA
16-unit!
Condominium
12/18/14
BEGOVICH + HAUG ARCHITECTS
begovich-haug.com
562-988-1174
DS PRODUCTS, INC.
scale: 3/16"=1'-0"0 5 10 ft.revision#1: 12/19/2014
attic!
fau
attic!
fau attic!
fau
attic!
fau
attic!
fau
twh
twhtwh
twh
twh
20'-8"1"20'-8"1"20'-8"1"20'-8"1"20'-8"2'-6"39'-4"1'-4"20'-8"1"20'-8"1"20'-8"1"20'-8"1"20'-8"
103'-8"2'-6"37'-8"3'-0"43'-2"15'-6"15'-6"10'-5"10'-5"15'-6"15'-6"15'-6"
103'-8"
5'-2"15'-6"1"15'-6"2'-10"4'-9"2'-10"15'-6"1"15'-6"2'-10"4'-9"2'-10"15'-6"
5'-2"
upupup
up up
dn.dn.dn.
dn.
dn.
refrefref
ref ref
dwdwdw
dw dw
living!
11'10"x14'10"
living!
11'10"x14'10"
living!
11'10"x14'10"
living!
11'10"x14'10"
living!
11'10"x14'10"
dining!
10'0"x9'4"
dining!
10'0"x9'4"
dining!
10'0"x9'4"
dining!
10'0"x9'4"
dining!
10'0"x9'4"
m.bedroom!
13'2"x12'0"
m.bedroom!
13'2"x12'0"
m.bedroom!
13'2"x12'0"
m.bedroom!
13'2"x12'0"
m.bedroom!
13'2"x12'0"
bath
bath
bath
bath bath
entryentryentry
entry entry
m.clstm.clst m.clst
m.clst m.clst
entry!
porch
entry!
porch entry!
porch
kitchen!
10'0"x8'2"
kitchen!
10'0"x8'2"
kitchen!
10'0"x8'2"
kitchen!
10'0"x8'2"
kitchen!
10'0"x8'2"
upupup
up up
bedrm 2!
12'6"x10'6"
bedrm 2!
12'6"x10'6"bedrm 2!
12'6"x10'6"
bedrm 2!
12'6"x10'6"bedrm 2!
12'6"x10'6"
bathbathbath
bath bath closetclosetcloset
closet closet
2-car garage !
20'0"x 20'0"
2-car garage !
20'0"x 20'0"
2-car garage !
20'0"x 20'0"
2-car garage !
20'0"x 20'0"
2-car garage !
20'0"x 20'0"
up
dryerdryerdryer
dryer dryer
washerwasherwasher
washer washer
range!
micro
range!
micro
range!
micro
range!
micro
range!
micro
HCD accessible!
adaptable unit
HCD accessible!
adaptable unit
unit #16!
plan 1
unit #12!
plan 1 unit #15!
plan 1
unit #13!
plan 1 unit #14!
plan 1
unit #16!
plan 1
unit #12!
plan 1
unit #15!
plan 1
unit #13!
plan 1
unit #14!
plan 1
HCD accessible!
adaptable unit
dn.
Second Floor Plan
First Floor Plan
up
HCD accessible!
adaptable unit
up
A-4.2Bldg. C Elevations
Magnolia Townhomes749 Magnolia Ave!
Carlsbad, CA
16-unit!
Condominium
BEGOVICH + HAUG ARCHITECTS
begovich-haug.com
562-988-1174
DS PRODUCTS, INC.
scale: 3/16"=1'-0"0 5 10 ft.revision#1: 12/19/2014
12/18/1
4
2x6 wood!
rafter
2x6 wood!
rafter
plaster!
foam!
plant-on
deco plaster!
foam corbel
deco plaster!
foam corbel
exterior!
plaster exterior!
plaster
4" plaster!
foam trim
4" plaster!
foam trim
stone!
veneer
stone!
veneer
mission style!
conc. roofing
mission style!
conc. roofing
plaster!
chimney
exterior!
plaster
2x6 wood!
rafters
roll-up!
garage!
door
vinyl window!
w/plaster!
foam trim
plaster!
foam trim
mission style!
conc. roofing
deco. plaster!
plant-shelf
painted!
downspout
Driveway (West) Elevation
mission style!
conc. roofing
deco. door!
w/transom!
window
plaster!
foam trim
vynil french doors!
w/temp. glass
Sideyard (East) Elevation
42" high!
wood!
guardrail
entry stairs!
w/wood!
guardrail
exterior!
plaster
2x6 wood!
rafters
mission style!
conc. roofing
vinyl window!
w/plaster!
foam trim
deco. plaster!
plant-shelf
vinyl window!
w/plaster!
foam trim
vinyl window!
w/plaster!
foam trim
4'6" high!
plaster!
patio wall
4'6" high!
plaster!
patio wall
Rear yard (South) Elevation Magnolia Ave (North) Elevation
covered entry!
porch w/stairs
vinyl window!
inset
covered entry!
deck w/stairs
deco plaster!
foam corbel
4'6" high!
plaster!
patio wall
deco. plaster!
plant-shelf
4" plaster!
foam trim
stone!
veneer
stone!
veneer
42" high!
wood!
guardrail
6x6!
wood!
post
6x6!
wood!
post
stone!
veneer8'-1"8'-1"9'-1"9'-1"top of slab top of slab
finish grade finish grade
top plate top plate
top plate top plate
2nd floor 2nd floor
6"6"6"8'-1"9'-1"top of slab
top plate
top plate
2nd floor
finish grade6"8'-1"9'-1"top of slab
top plate
top plate
2nd floor
finish grade 5'-6"entry!
landing9'-6"max building htfinish grade25'-6"roof peak
111CT 14-05XXXX0'2'4'6'8'10'20'30'40'50'SCALE: 1" = 10'-0"SITESITECONCEPTUAL LANDSCAPE PLAN3112