Loading...
HomeMy WebLinkAbout2016-07-20; Planning Commission; ; CUP 16-02 - VERIZON CARLSBAD VILLAGEThe City of Carlsbad Planning Division A REPORT 1r0 THE PLANNING COMMISSION ltemNo. G) P.C. AGENDA OF: July 20, 2016 Application complete date: March 24, 2016 Project Planner: Austin Silva Project Engineer: Kyrenne Chua SUBJECT: CUP 16-02-VERIZON CARLSBAD VILLAGE-Request for approval of a Conditional Use Permit to allow for the installation, operation, and maintenance of a new unmanned Wireless Communication Facility (WCF) consisting of three sectors of four antennas (12 total), 12 Remote Radio Units (RRU), three surge protection units, two equipment cabinets, one stand-by generator, and one Global Positioning System (GPS) antenna mounted behind new radio frequency (RF) transparent screens on the roof of an existing office building located at 3150 Pio Pico Drive and in Local Facilities Management Zone 1. The City Planner has determined that the project belongs to a class of projects that the State Secretary of Resources has found not to have a significant impact on the environment, and is therefore categorically exempt from the requirement for the preparation of environmental documents pursuant to Section 15303-New Construction of Small Structures, of the State CEQA Guidelines. I. RECOMMENDATION That the Planning Commission ADOPT Planning Commission Resolution No. 7182 APPROVING CUP 16-02 for a period of 10 years, based on the findings and subject to the conditions contained therein. II. PROJECT DESCRIPTION AND BACKGROUND The proposed unmanned WCF consists of roof mounted telecommunication equipment cabinets, a roof mounted standby generator, 12 panel antennas, 12 RRU, three raycap surge protection units, and one GPS antenna. The panel antennas will be mounted on the roof behind a new RF transparent screen and will not be visible from the street or the surrounding properties. There is an existing roof screen on the roof to screen existing mechanical equipment that will be raised three feet and ten inches in order to screen the antennas and related equipment. The existing roof screen is constructed of wood and will be replaced with a new RF transparent material and textured with stucco and a cornice will be added to the top of the screen to integrate better with the architecture of the building. Other associated equipment will not be visible as the four RRU units will be mounted behind the antennas and the GPS antennas will be mounted to the equipment cabinet. There are no proposed ch<mges to the landscaping and no parking spaces will be removed to accommodate the new WCF. The facility is unmanned and operates 24 hours a day, seven days a week. Since the facility is unmanned, it will not generate any traffic. The facility will be connected to a central network operations center that monitors the facility's status. Routine maintenance occurs once every four to six weeks to ensure the equipment is operating within normal specifications. If an emergency arises, maintenance crews are dispatched to correct the situation. CUP 16-02-VERIZON CARLSBAD VILLAGE July 20, 2016 Page 2 Wireless carriers construct new WCF's in a specific area to achieve one ofthe following: • Provide signal coverage of sufficient strength to achieve consistent, sustainable, and reliable service to customers at a level sufficient for outdoor, in-vehicle, and in-building penetration with good voice and data quality during high demand periods. • Provide additional system capacity to ensure there is sufficient signal capacity to offset the contraction of signal experienced when nearby sites become overloaded and more enhanced voice and data serviCI~s are uses, thereby creating periodic gaps. With heavy use, this contraction of signal is intensified due to the unique properties of digital radio transmissions. In this case, the proposed site is a capacity site. Verizon's radio frequency (RF) engineers also observed that the existing/surrounding Verizon sites are becoming overloaded, and determined that an additional facility is needed in order to relieve network traffic congestion and ensure reliable levels of service. Table A below includes the General Plan designations, zoning and current land uses ofthe project site and surrounding properties. TABLE A-Zoning & General Plan Designations - location General Plan Designation Zoning Current Land Use Site Office Office Office building North Office Office Office building South Office Office Single-family residential East R-8 RD-M-Q Single-family residential West Transportation Corridor (T-C) Transportation Corridor (T-C) Interstate 5 Freeway Ill. ANALYSIS The proposed project is subject to the following ordinances, standards, and policies: A. Office (O) General Plan Land Use designation; B. Office (0) Zone (Chapter 21.27 of the Carlsbad Municipal Code); C. Conditional Use Permit regulations (Chapter 21.42 of the Carlsbad Municipal Code); D. Wireless Communication Facilities Policy (City Council Policy Statement No. 64); and E. Growth Management The recommendation for approval of this project was developed by analyzing the project's consistency with the applicable regulations and policies. The project's compliance with each of the above regulations is discussed in the sections below. A, Office (O) General Pllan land Use Designation The project site is designated Office (O) on the city's General Plan land Use Map. The proposed WCF is consistent with the 0 General Plan Land Use designation in that the 0 Land Use designation does not preclude the use of wireless communication facilities. The proposed use will serve the residential and business community and region as a whole, including emergency services. Therefore, the proposed WCF use is consistent with the 0 General Plan Land Use designation. CUP 16-02-VERIZON CARLSBAD VILLAGE July 20, 2016 Page 3 B. Office (O) Zone, Chapter 21.27 of the Carlsbad Municipal Code The proposed WCF is located on the rooftop of an existing office building within the Office Zone. Wireless communication facilities, such as the proposed project, are allowed in all zones including the Office Zone with approval of a CUP. The required CUP findings (discussed in Section C below) can be made for the proposed WCF as it is a desirable public convenience and is compatible with its surroundings. The 12 panel antennas will be mounted on the roof behind an RF transparent screen wall that integrates with the architecture of the office building. The maximum above ground height of the screen walls is 35 feet, which is the maximum height permitted in the Office zone. The WCF does not impact the setback requirements of the Office zone because the antennas and all associated equipment will be located on the roof of the existing building and no modifications to the building envelope are proposed. C. Conditional Use Permit Regulations, Chapter 21.42 of the Carlsbad Municipal Code The proposed project is a use which is allowed in the Office Zone (O) subject to the approval of a CUP. Chapter 21.42 of the Carlsbad Municipal Code requires that four findings be made in order to approve a CUP. All of these findings can be made for this project as discussed below. Conditional uses such as WCF possess unique and special characteristics that make it impractical to include them as permitted uses "by right" in any of the various zoning classifications (i.e. residential, commercial, office, industrial, and open space). The authority for the location and operation of these uses is subject to City Council Policy Statement No. 64 -Wireless Communication Facilities Policy (see discussion D below), Planning Commission review, and the issuance of a CUP. Staff has reviewed the proposed project and found that all of the necessary findings can be made to approve the CUP. The required findings and satisfaction of these findings are provided below. 1. That the requested use is necessary or desirable for the development of the community, and is in harmony with the various elements and objectives ofthe general plan, including, if applicable, the certified local coastal program, specific plan or master plan, in that the proposed WCF use is necessary and desirable for the development of the community because of the benefit and demand for digital communications and data transmiss:ions for businesses, individuals, public agencies and emergency service systems. The proposed use is consistent with the General Plan in that the Office Land Use designation does not preclude the provision of WCF uses, nor is it detrimental to existing permitted uses in the vicinity in that the WCF exhibits stealth design and only minor alterations to the existing site are proposed. 2. That the requested use is not detrimental to existing uses or to uses specifically permitted in the zone in which the proposed use is to be located in that the proposed WCF visual impacts will be minimized as the 12 panel antennas and all other associated equipment will be roof mounted on an existing office~ building and will be screened behind an RF transparent screen wall that will be finished with stucco and will have cornice at the top, which will integrate with the architecture of the building. There are no other changes proposed to the exterior of the building or to the landscapinig on-site. 3. That the site for the proposed conditional use is adequate in size and shape to accommodate the yards, setbacks, walls, fences, parking, loading facilities, buffer areas, landscaping and other development features prescribed in this code and required by the city planner, planning commission or city council, in order to integrate the use 'with other uses in the neighborhood in that the 12 panel antennas and all other associated equipment will be roof mounted on an CUP 16--02-VERIZON CARLSBAD VILLAGE July 20, 2016 Page 4 existing office building behind RF transparent screen walls that will be finished with stucco with a cornice at the top, which will integrate with the architecture of the building. Installing the Wireless Communication Facility on the roof does not require any modifications to the building envelope that would alter the setbacks for the existing office building nor does it require the removal of any parking spaces or changes to the site's landscaping. The RF transparent screen wall will have a ma>timum height of 35 feet, which complies with the allowed height of the Office (0) Zone. 4. That the street system serving the proposed use is adequate to properly handle all traffic generated by the proposed use in that the use generates very little traffic, requiring only routine monthly maintenance visits and occasional visits in response to operational problems. Pio Pico Drive and Pine Avenue will be used to access the site. The existing street system is adequate to property handle any traffic generated by the use. D. City Council Policy Statement No. 64-Wireless Communication Facilities Pursuant to Carlsbad Municipal Code Section 21.42.140(165)b, a WCF Conditional Use Permit application that does not comply with the preferred location and the stealth design review and approval guidelines of City Council Policy Statement No. 64 shall be conditionally approved or denied by the Planning Commission. The WCF project does not comply with the setback requirement as listed in Design Guideline B.2.a. of City Council Policy Statement No. 64. Specifically, a WCF should, be set back from the residential zone boundary a minimum distance equal to the above-ground height ofthe antenna. The top of the 6'9" tall antennas measure 35 feet from grade, which would require a 35 foot setback from the residentially zoned properties from the east and south. The antennas located closest to the east property line are setback 16 feet, and the antennas located closest to the south property line are setback 32 feet. However, there is no visual impact by locating the antennas closer to the property line than the required distance of 35 feet as the 12 panel antennas will be roof mounted on an existing office building and will be screened behind an RF transparent screen wall that will be finished with stucco and will have cornice at the top, which will integrate with the architecture of the building. Additionally, the proposed WCF facility meets the Federal Communications Commission standards for radio frequency (RF) compliance and will not expose people to harmful levels of RF. Verizon Wireless analyzed 11 other potential sites within the vicinity of the proposed location and determined they were not feasible for reasons such as zoning, structural integrity of rooftops, no interest from owners and antenna heights not being high enough to gain maximum coverage. The WCF has been designed using "stealth" design techniques to the extent feasible and is consistent with the Design Guidelines listed in City Council Policy Statement No. 64. Furthermore, the Office Zone is considered a preferred location for a wireless communication facility. E. Growth Management The proposed WCF is located in Local Facilities Management Plan Zone 1. Installation of the facility on the existing site and monthly facility maintenance visits will not result in increased public facilities demands; therefore, the proiPosal will not exceed performance standards for public facilities. CUP 16-02-VERIZON CARLSBAD VILLAGE July 20, 2016 Page 5 IV. ENVIRONMENTAL REVIEW The City Planner has determined that the project belongs to a class of projects that the State Secretary for Resources has found do not have a significant impact on the environment, and it is therefore categorically exempt from the requirement for the preparation of environmental documents pursuant to Section 15303 (New Construction of Small Structures) of the state CEQA Guidelines. Additionally, as Verizon Wireless must comply with FCC regulations, radio frequency emissions from the proposed facility are below levels established as acceptable by the FCC, and are therefore not considered a health hazard. In making this determination, the City Planner has found that the exceptions listed in Section 15300.2 of the state CEQA Guidelines do not apply to this project. ATIACHMENTS: 1. Planning Commission Resolution No. 7182 2. Location Map 3. Disclosure Statement 4. Reduced Exhibits 5. Exhibits "A"-"I" dated July 20, 2016 SITE MAP m c ::0 ~t-----1 )>.t-----1 '------1 f1 • N NOT TO SCALE Verizon Carlsbad Village CUP 16-02 r------------·; (cicyof Carlsbad DISCLOSURE STATEMENT P-1(A) Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov Applicant's statement or disclosure of certain ownership interests on all applications which will require discretionary action on the part of the City Council or any appointed Board, Commission or Committee. The following information MUST be disclosed at the time of application submittal. Your project cannot be reviewed until this information is completed. Please print. 1. APPLICANT (Not the applicant's agent) Provide the £.9MPLETE, LEGAL names and addresses of ALL persons having a financial interest: in the application. If the applicant includes a corporation or partnership, include the names, titles, addresses of all individuals owning more than 10% of the shares. IF NO INDIVIDUALS OWN MORE THAN 10% OF THE SHARES, PLEASE INDICATE NON-APPLICABLE (N/A) IN THE SPACE BELOW. If a publicly-owned corporation, include the names, titles, and addresses of the corporate officers. (A separate page may be attached if necessary.) Person Corp/Part Verizon Wireless Title Title. ____________ _ Address __________ _ Address 15505 Sand Canyon Drive, Irvine CA 92618 2. OWNER (Not the owner's agent) P-1(A) Provide the COMPLETE. LEGAL names and addresses of ALL persons having any ownership interest in the property involved. Also, provide the nature of the legal ownership (i.e., partnership, tenants in common, non-profit, corporation, etc.). If the ownership includes a corporation or partnership, include the names, titles, addresses of all individuals owning more than 10% of the shares. IF NO INDIVIDUALS OWN MORE THAN 10% OF THE SHARES, PLEASE INDICATE NON-APPLICABLE (N/A) IN THE SPACE BELOW. If a publicly-owned corporation, include the names, titles, and addresses of thE~ corporate officers. (A separate page may be attached if necessary.) Person Bill Larson Corp/Part Waters Edge Properties, LLC Title Owner Title Addres5 3150 Pia Pico Drive Carlsbad, CA 92008 ------------------ Address ____________ _ Page 1 of2 Revised 07/1 0 ,.. ! 3. NON-PROFIT ORGANIZATION OR TRUST If any person idEmtified pursuant to (1) or (2) above is a nonprofit organization or a trust, list the names and addresses of ANY person serving as an officer or director of the non- profit organization or as trustee or beneficiary of the. Non Profit/Trust. Non Profit/Trust. _________ _ Title Title ____________ _ Address __________ _ Address. ___________ _ 4. Have you had more than $500 worth of business transacted with any member of City staff, Boards, Commissions, Committees and/or Council within the past twelve (12) months? D Yes l.f I No If yes, please indicate person(s): __________ _ NOTE: Attach additional sheets if necessary. e above information is true and correct to the best of my knowledge. Signature of applicant/date Print or type name of owner Print or type name of applicant Signa ure of owner · pplicant's agent if applicable/date H iAf e-e ·~1J · P-1(A) Page 2 of2 Revised 07/10 • ver1zon I OVE~-o~EIGHT I CARLSBAD VILLAGE 3150 PIO PICO DRIVE CARLSBAD, CA 92008 VICINITY MAP THOMAS GUIDE PAGE: 11 OS -F'S ~ ADDRESS 3Hi0 PID PICO DRIVE CARLSBAD,. CA. ilOOII DIRECTIONS: (FROW VZW'somCEStN IRVINE): t. HEAD SOUlliWEST ON SAND CANYON AVE TOWARD IWIIWICI. PKWY 2, MERGE OHTO l-o405 S VIA THE IWIP TD SAN DIEGO J, MERGE ONTO 1-!5 s 4. TAKE THE CARLSBAD VILI.AGE DRIVE EXIT AND TURN LEfT, 5. TURN RIGHT ONTO PIO PICO DR. D£SnMAT10H WILL BE ON THE LEFT AFTER OAK AVE. SCALE CONSULTANT TEAM ARCHITECT: IIOOTHA:SUAREZARCIITECTURE,ttiC. 32liCARLSBAOVILL\GEDRIVE,S1JITED2 CARLSBAD, CA. 92008 (780}~1474 (780) -434-BSH (FAX) SURVEYOR: FLOYDSUR'I£YIHG 2P!e OLD TOWN FRONT ST, SUITE 205 TEMECULA. CA. 82580 (11!11)91U-8M7 LEASING/PLANNING: COREDEYEI.OPWENTSERVICES ROlWIA AWlNl 21411SATURNSTREET 11REA, CA 12821 (714) 382-11034 ramln\Ooo!11.ua.oom EARTHWORK QUANTITIES CUll 37C,'/', mL: J7C.'r. IWPORT: OC.Y. EXPORT: DC.'/', REMEDIAll OC.Y. PERMITS REQUIRED e PRELIWIHARY Rtvltw APPUCATlON PROJECT SUMMARY APPLICANT: VERIZON WIRELESS ISSOll SAND CAN'I'ON AVENUE IRVINE,CA12ll18 CONTACT; ROXANA .WINI PHONE:. (714) 312-8054 OWNER: WATERS EDGE PROPERTIES, U.C JI!IOPIOPICODRIVE CARI.SIIAO,CA.I2DOII SITECONTACT:BIU.I.ARSOH PHONE. (760) 703-7600 PROJECT DESCRIPTION: eiNSTAI..lATION OF 'IEJIIZOM WlltElE$5 TELECOWIIIUNtC.t.TIONS EQUIPWEKT CABINETS ON A MEW EQUIPMENT Pt.ATfORW ON ROOF or EXmlNO BIJa.DINO (WCE DESIGN) eiMSTAI..lATION or A 15kW' NATURAL GAS ENCLOSED STANDBY I>ENERATOR MOUNTED ON PROPOSED EOUIPMEKT PlATFORM ON ROOF or EXISTINO BUI.DIMO (WCE DESIGN) e INSTAI..lATION Or lliREE (3) YERilON WIIEIDS ANTENMA ~+~~~ii~~~~::(TO~~:fVE •:Jrc~~Jro~~~.M:l ~u~=~r:::, PER PROPOSEDAMTENIWi ·~~~u~~m:oEijtJ:b :C::~~ .. g=C:RGE SCREEN WAUS ·~~T~~r:o<~&u=:~ E/111 GPS eUSE Or AH EXIS'I'IMO El.ECTRICAL SERVICE INSIDE EXIS'I'ING ELECTRICAL ROOM e INSTAI..lATION Or A NEW TELCO !iEIMCE CONNECTION niOU AM EXISTING TELCO MAHHOI..E • NO LANDSCAPE OR IRRICATION IS PLANNED FOR THIS PROJECT PROJECT ADDRESS: 31GOPIOPICODRIVE CARLSBAD, CA 120011 ASSESSORS PARCEL NUt.iBER: EXISTING ZONING: R-P RESIDDmAL PROfESSIONAL TOTAL SITE AREA: !7·~~~ PROPOSED LEASE AREA: EQUIPMEKTPlAlFORM: MOTE: THERE ARE NO EX!STINO TEL£CQI,IIIIUNICATION rAC!UTIES ON THIS PROPERTY SHEET SCHEDULE T-1 TITLE SHEET AND PRO.ECT DATA A-D SITE PUN A-1 -...... A-2 EQUIPIIIENT PlATfORM PU.N A-3 ANTDIHAPI.ANS A-4 EXTERIOR ELEVATIONS A-5 EXTERIOR ELEVATIONS LS1 SITE SURVEY GENERAL INFORWATION LS2 SITE SURVEY GENERAL INFORMATION LEGAL DESCRIPTION FORADDIT10NAl.L.£lW..D£SCR!PTION!NFORIU.TIOHSEESHE£TLS1 ACCESSIBILITY DISCLAIMER THIS PROJECT IS AM UNOCCUPIED WIREI.ESS PCS ~~~~~w~ ~UJlu~~~.JreJg ~STATE ARCHITECf, IS EXEMPT FROIII DISABLED ACCESS REQUIREIIIEKTS. APPLICABLE CODES ALL WORK SHid..L COMPLY WITH lliE FCI.l.QWING APPI..ICAliLE COD£Sl C.WFllRM!A STATE BUILDING CODE, Tm.E 24. 2013 EDmON CALIFORNIA PLUMBING CODE, 2DI3 EDmON CALIFORNIA IIIECHANICAL CODE. 2D13 EDITION C.WFORNIA EI.EC'IRICAL CODE, 2013 EDITION C.WFORNIA FIRE CODE, 2013 EDITION C.WFORNIA ENERGY CODE, 2013 EDmDN IN lliE EVENT OF CONFUCT, THE IIIDST RE5TRICTIVE CODE SHALL PREVAIL CUP 16-02 Bg<filhz8- fl~CHITECTU~E :: II'ICORPORJITED (760)4l4•U74 ===··=== PREPARED FOR verizon" P.O. BOX 19707 IRVINE, CA 92623-9707 (949) 286-7000 ===··=== APPROVALS ~ ~ --·-__ ,_ PROJECT NAME CARLSBAD VILLAGE 3150 PIO PICO DRIVE CARLSBAD, CA 92008 SAN DIEGO COUNTY ===::=== 09/15/IS D8/ZZ/15 10/0Z/13 10/DS/15 11/:S0/15 12/D7/15 12/1D/15 D2/D1/1& D2/10/16 D3/DI/16 D'/D7/16 05/02/16 DRAWING DATES 9D%ZD(u) 1DD" ZD (~o) 1DD"ZDRE:\IISIDN1 1DD"ZDRE:\IISIDN2 1DD"ZDR!:VISION.3 1DD"ZDR!:VISION4 100"ZDR!:VISION5 1DO%ZDR!:V1SIDN6 IDD%ZDR!:VISIDN7 :gg~ ~g :g:~:g~ : !==· 1DO"ZDRE\IISIDN1D n ===::=== SHEET TITLE TITLE SHEET • PROJECT DATA ===::=== PROJECTS\VERIZDN\140Z!i ===··=== T-1 ENLARGED UTILITY PLAN ~UI"•1'4' ENLARGED \ITILITY PLAN NOTES: <\) EXISTING CORRIDOR <i> EXISTING m.co ROOM ~ EXISTING ElfClRICAL ROOW <3) EXISTING 400A. 120/208V, 311, 4W SWITCHGEAR (PCNER SOURCE) <§> EXISTI~ I.ANDI..ORD ldETEH NO. SOOE 11~74J2~ <i)' EXISTING BREAKER PANEL q) .go~ =t.l~~62~sr-~o:~EDLO=~N~ELESS <!> EXISTING WATER HEATER ~ EXISTING AT&T t.IPOE !.AND UNE J' ~ EXISTING AT&:T ldPOE !.AND UNE <15~ <0>-EXISTlt¥J DOOR (lYPJCAL) 4} EXISTING CONCRETE SIDEWALK ~ EXIST1N01.ANDSCAPEAREA ~ EXISTING CONCRETE BLOCK WALl. TO REWJN ~ ~ PROPOSED 17x.30 TELCO PUll BOX 4}:> PROPOSED -4"• TEt.CO COto.JIT ROUTING WOUN'TED TO EXtaOOR BUILDtNG WAlL UP TO ROOF LEVEl. 4) PROPOSED ELEClRICAL CONOUrT ROUTING 1.40UNTED TO OO'ERIOR BUILDING WALL UP TO ROOF LEVEl. cO> PROPOSED EI.ECTRICAL CONDUIT ROUTING MOUNl'fD 10 CflUNG FROt.l t.IETER TO EXT[R)OR WALL 0. ~~"< / _/ ' / / / / -~ ~~-/ ,/-\. o~-,/-\ SETBACK NOTES: G) FRONT YARD SETBACK .. 20'-0" ® SIDE YARD SETBACK • 10X Of LOT WIDlH {!) STREETSIDESEIBACK•10'-0" @RCARYARD~•2ml:OFLOT-.,Iml (NOT TO EXCEED 20'-oj CUP 16-02 0 RESIOENTW.. SETBACK -ABOVE GROUND HEIGHT OF FACIUTY I /_/ {> __ /-\\ .. , / oosnNG \ v. BUILDING \ I • M ~ / \ ' -\ ' \ " ---'--·--/ ' . ~'--· -"--\ \1-' \ ~PROPEJ<IY, UNE I '·· <>LROO""'~ .... '"'""'' GAMIAA SECTOR AZIMUTH tO' • / __ / / _./' //" / / / EXlS11NG PR~..o.Y {1YPICAL) \ ' \ r ~0(,2D8V, ':';,i""'on~' . ... $ I V CNP<'"-"'"'"""" ~ """' ' ' =~;::· EXISTING ASPI-W.T PAVED PARKING AAE'A NiD DRWEWAY PROPOSED VERIZDN WIRELESS EQUIPMENT ON A NEW RAISED STEEL PlATFORM ON ROOf OF EXISTING BUILDING (MCE DESIGN) • BEI"A SECTOR AZII.4\JTH24Q" SITE PLAN ICMII:1"·•~ \ _...;!' ,;»;ii' 0. ~~ /EX!snNOA/&I'""HOLE / /' /,/ ~~/'--~..f-m" UNE / . ~ / EXIS11NQUTIUJYPOLEfP20746 EXIS11NGELECrRICALTRANSF"ORMER f!l3B.l7066680 .. AlPHA SECTOR AZIMUTH 120" HOUDI'Y PARK APN: 2te-111-27-00 --TliE PROPERlY BOUNOARY UNES SHOWN ON TliiS DRAWING ~FO~~EFERENCE ONLY, A BOUNOARY SURVEY WAS NaT B&%lhz&- I'IRCHITECTU~E :: INCO~PO~I'ITED ===··=== PREPARED F'OR verizon" P.O. BOX 19707 IRVINE, CA 92623-9707 (949) 286-7000 ======== APPROVALS ~ ~ ~ ======== PROJECT NAME CARLSBAD VILLAGE 3150 PIO PICO DRIVE CARLSBAD, CA 92008 SAN DIEGO COUNTY ======== DRAWING OATES 09/HI/.15 90" ZD (u) 08/22./15 IOil"ZD(.e) 11}/02./1.5 100"ZDREVIStON1 10/t!S/15 100"Z0REVISION2 [II 11/lD/15 100"ZDREVISIONJ 12/07/15 10D"ZDREVISION4 12/10/15 1DO"ZDREVISION5 02/01/16 10D"ZDREVISION6 02/10/15 tDO"ZDREVISION7 Ol/01/1S ]gg: ig ~g:;:g~ : ~::: Ol/07/18 05/DZ/16 IOD"ZDREVISIDN10 n' ======== SHEET TITLE SITE PLAN ===··=== PROJECn.\VERIZON\14025 ======== A-0 • BET" SECTOR AZlt.lllnl240' \ _;t/~X\\: \ ~'< ADJN::EKTRESIDENTIAL \ • ;~. PROPERlY LNE ~"' (TYPioo.) \ ~j;.i. ~ \ . ., .... /#~ \ , )1(·\l> \ \ \ \ \ \ / V ~OO~SIO~ PROPERlYUNE (TYP<oo.) ~~uJta;rgR • ~ 0 ROOF PLAN ~ ~, PROPOSED VERIZON WlRELE5S EQUIPMENT ON A NEW RAISED STEEL f'I....IITroRN ON ROOf OF EXiSTING BUILDING (t.ICE DESIGN) .. 't':"~~: CUP 16-02 ROOF PLAN NarES: <$ PROPOSED unUTY CONDUIT RDlffiNG t.IOUNTEO TO EXJERIQR BUILDING WH.L FROW GRADE t.e.a.. TO ROOf' ~ ~NO~'ifct~o~~~o~·~o'lrrc~~ PREUWINAR'f UTILITIES ROUTE TO BE FIB.D VERFlED AND ADJUSTED Aec:ORO!NGLY DURING COMSTRucr!DN ~ PROPOSED COAX CABLE TR.IIY ON 4 lC 4 P'I/C SlEEPERS 0 4'-0" D.C. t.IAX., PREUt.IINMYCOAX~ROUTETOBEFIEI.DVERIFIEDANDADJUSTED ACCORDINGLY DURING COHSTRUCTION ¢-PROPOSED 'llW"-WAU<' PADS (TYPICAL) <V EXISTING WOOD NECHNiiOO.. EQUIPMENT SCREEN, ADO J'-10" SCREEN HEIGHT EXTENSION. REFINISH IN snJCCO TO W.TCH EXISl\NG BUILDING (TYPICAL) ¢' EXISTING WOOD SCREEN BRACE. ADD NEW BRACE TO EXISTING SLEEPER MOUNT f'OR NEW SCREEN HEIGifT ADDITION (TYPICAL) * EXISllNGSLEEPER(TYPICH..) EXIS11NG BUIUllNG EXlERIOR WAU. BELOW (SHOWN DASHED) EXISTING ARCHrmm.JRAI... CORNICE ~ EXISTING STRUr:TURAI... BEARING WALL BELOW (SHOWN DASHED) 4) EXISTlNG PARAPEJ"WALL ~ EXIS11NG BUILT-UP ROOf' ~ EXISTING ROOf MATS {SHOWN DASHED) ~ EXISTING ROOf~ (l'r'PICAI..) ~ EXISTING ROOF PI..AlfORM 4) EXISTING ROOF HVAC ~ EXISTING ROOF AIR CONOffiONER ~ EXISTING ROOF El.ECffiiCAI. 4) EXISTING SOLAR l\JBE ~EXISTINGSAlEl..LII"EOlSH 4> ElUSTING SIC'f LIGHT ~EXISTINGROOFACCESS!-IATCH <@> EXISTING CRICKET ~ EXISTING ROOF DAA!N {l'I'PICAL) 4? PROPOSED ARCtilfECTURAL FOAM CORNICE: DETAILED, TDCTURED N-10 FINISHED TO MATCH EXISTING (SHOWN DASHED) ~ EXISTING L.lGHT FIXTURE NOUNlED ON PARAPET TO BE RELOCA.lED (SHOWN DASHED) 4) ~~~~N9!:r ~ ~~:"~~~:RJf~T~ G 4'-o• D.C. MAX., PREJ..Jidlw.RY IJTIUTY ROUTE TO BE FJELD VERIFIED AND ADJUsr£0 ACCORDINGLY DURING CONSTRIJCllON SCREEN WAll. 8ECI1CN EXISnNG ROOF FRAMING -BOOTH g_ =bUAKfZ_ ~RCHITECTURE :: INCO~PORATEO === .. === PREPARED FOR verizon" P.O. BOX 19707 IRVINE, CA 92623-9707 (949) 286-7000 ===··=== APPROVALS ~ EE/IN ~ EE/OUT ===" ~ PROJECT NAME CARLSBAD VILLAGE 3150 PIO PICO DRIVE CARLSBAD, CA 92006 SAN DIEGO COUNTY === .. === DRAWING DATES 0'1/1$/15 90%ZO(.•) 0'1/22/15 100"ZD(sa} 10/02/15 100"ZDREVISION1 10/05/15 100"ZDREVISIDN2 11/JD/15 100"ZDREVISIDNJ 12/07/15 1001GZDREVISIDN4 tn 12/10/15 100"ZDREVISIONS 02/01/16 1DO"ZDREVISION6 02/10/16 100"ZDREVISION7 OJ/01/16 100" ZD REVISION II ~·• OJ/07/16 100"ZDREVISION9 •• 05/02/16 100"ZDREVISION10 •• ===··=== SHEET TITLE ROOF PLAN ===··=== PROJECTS\V£RIZON\14025 ===··=== A-1 \\ /~~I~P~~UNE -( (EQUAl. TO ABOVE GROUND HEIGHT OF FACIU1Y) \ \ \ \ ~ ~\ \ \~ \ \ \ \ ' \ \ \ ' \ ' \ \\ '' \\ \ ~\ ~\ \ EQUIPMENT PLATFORM PLAN ICM.I!:tw-1'-0" NOre SEE SHE'fT A-3 FOR Nffi:NNA. A: COAX CAI'!l.E SCHEDULE AND FOR AI..PHA & BETA SECTORS ~', c( \ / <~ o .. ~~' CUP 16-02 EQUIPMENT PLATFORM PLAN NOTES: ~ ~~~ ~::w:~~~ENT ~ ~ ~ ~= ~~:m:r:Jo00=Er10ts"': ~~~[ BE REQUIRED) ~ PRCPOSEDFUSED DISCONNECTSWITCHUNISTRliTMOUNTED TO ENCLOSURE WALL ~NOT USED <l> NOT USED ~ PROVIDE AND INSTALL (1) ClASS "..aQ" ARE EXTINGUISHER IN A WEAlHERPROOF CABINET MOUNTED TO GUARDRAIL ~PROVIDE AND INSTAI.LBATTERYACIOSPIU.KIT(S) CAPABLE OF NElJTRAIJZlNG A SPILL FROM THE lARGEST eATmf'l' -$> PROPOSED "BAR Gttt.TE" DECK ~ PROPOSED 42" HIGH GALVANIZED SIEn. GUARDRAIL ~ == ~::;:~~:::f" =~SECTION FOR ClfAA ~NTENANCE ACCESS TO GENERATOR 4) PROPOSED PAIR J'-8" 'MOE HNGED GUARDRAIL SEcnoNS FOR CLEAR MAIKTEM.'.NCE ACCESS TO EQUIPMENT CABINETS ~ PROPOSED OPENING IN BAR GRATE FOR CXWC Cf.BLE RCUTING 8EI..OW CABINET (SHOWN DASHED) ~ PROPOSED GALVHIIZED S1EEL STAIRS WITH GRATING 1'RE.ODS ~ PROI>OSEDCN..Vn.IIZEOSTEELI-W-IDRAIL 4) PROPOSED S1EEL BEAM FRAAIE BELOW {SHOWN DASHED} ~ PROPOSED STm. PIPE COWI.4N BELOW (SHOWN DASHED} (TYPICAL Of 6) ~ PROPOSED PITCH POCKET (BELOW SHOWN DASHED)(M"'CIL) <(s> PROPOSED Ullurf CONDUIT ROliTlNG ON 4 x 4 PVC SlEEPERS 4) EXISTING STRUCTURAL BEARING WALL. BELOW (SHOWN DASHED) ~ EXIS11NG PARAPET WALL ~ EXISTING BUILT-UP ROOf ~EXISTING ROOF' W.TS {SHOWN DASHED) ~ PROPOSED 'lRAF'-M.K' PADS (l'YPICA!..) ~ EXISTING WOOD FRAME MECHANICAL SCREEN WALL. OCTDil HElGHl" .:S'-10" (TYPICAL) REMOVE EXISTING CEDAR WOOD PANELS AND REPlACE W11H Sl1lCCO FINISH TO MATCH EXISTINQ BU!UliNG ~ EXISTING WOOD POST (IYP~ ~ EXISTINGSI..EEPER(lYPlCAL.) ~ PROPOSED AACHITECTURAL FONol CORNICE N!JI:NE (SHOWN DASHED) ~ EXISTING WOOD BRACE TO REI.INN (TYPICAL} ~ PROPOSED WOOO BRACE FOR NEW SCREEN HEIGHT EXTENSION (rn>ICAI...) 4) EXISTING ROOF AIR CONDITlONER TO BE REI..OCATtD (SiiOWN DASHED) ~ PROPOSED RElOCATION Of EXISTING ROOF AIR CONOmDNER (FIEl.D VERIFY AND COORDNA.TE WITH OWNER) ~ EXISTING ROOf OUTlET TO BE REI..OCATED (SHOWN DASHED) 4? rno~~~~~ro~TEISTI~R~~rn ~ EXIS11NG WOOO GATE, REBUILD TO N~ SCREEN EXTENSION HEIGHT. PAINT TO MATCH PROPOSED STUCCO FINISH ~ PROPOSED 7'-o~ HIGH RF TRANSPARENT SCREEN (TYPICAL). RfTRANSPARENTioiATERIALTOBEDErAILED,TtXT\JREDAND FINISHED TO !.lATCH PROPOSED STUCCO FINI9i .. PROPOSED 4 x 4 RF TRANSPARENT FIBERGLASS lUBE FRAAIING {SHOWN SHADED)(TYPICAL) ~ =~~~H~~A=N%W~NTm ON ~ PROPOSED "elENA~ mco EQUIPt.IENT MOUNTED ON NEW UNISTRUT 'H-FRAME' ATTACHED TO WALL 4} PROPOSED VERilON WIRELESS ANTENtoo loiOUNTED BEHIND NEW Rf TRANSPARENT SCREENS (TYPICAL) 4} PROPOSED VERilON WIRELESS RRU loiOUNT£0 BEHIND PROPOSED ANTENNA. (IYPICAL} ~ PROPOSED RAYCAP DC SURGE PROTECTION UNIT UNISTRUT loiOUNml TO SCREEN W,o\U. ~ PROPOSED COAX CABL£ TRAY ON 4 x 4 PVC SLEEPERS ~ PROPOSED CQf.X CABLE TRoW loiOUtn'ED TO SCREEN WALL {SHOWN DASHED) 4) EXISTING ROOF VENT (IYPICAL} 4:9 EXISTlNG ROOF PLATfORM ~ EXISTING ROOF HVAC ~ EXISTlNG ROOF AIR CONomoNER ~ EXISTING ROOF EI..Eat'RICAI.. 4} EXISTING ROOF OlfTl£l' ~PROPOSED UNISTRUT (S!iO\IIN D4SHED) ~ PROPOSED unUTY CONDUIT ROUliNG MOUNTED TO EXTERIOR BUilDING WAll. FROM GRADE LE.VEl TO ROOF B~lhz&- .<!RCHIT~CTUR~ :: lr!CORPORATED ===··=== PREPARED F'OR verizon"' P.O. BOX 19707 nMt.t~ c• 92623-9707 ...... (949).zas-=-iooo ===··=== APPROVALS OATE ~ DATE ~ '"' ~ EE/D1JT ~ PROJECT NA~E CARLSBAD VILLAGE 3150 PIO PICO DRIVE CARLSBAD, CA 92008 SAN DIEGO COUNTY ===::=== 09/1~/1~ 09/22/1S 10/02/15 10/05/15 11/30/15 12/07/15 12/10/15 02/01/16 02/10/1& 03/01/1& 03/07/'IB OS/02/16 DRAWING DATES 90XZD(u} 100XZD(•8) 1DDXZDREVISION1 1DDXZDREVIS10N:Z 100XZOREV1SION3 1DOXZDREV1SION4 IDDXZOREV1SIONS !'" 1DDXZOREVIS10N6 •• 100XZOREVIS10N7 11 1DOXZOREVISION8 11 \ODXZDREVISION9 •• \OOXZOREVISION\0 ,,: ===··=== SHEET TITLE EQUIPMENT PLATFORM PLAN ===··=== PROJECTS\VERIZON\1o«l2S ===::=== A-2 o~GH~ ~~IENNA PLAN 'B' ~ "~ ANTENNA AND COAXIAL CABLE SCHEDULE :1"""'"'1""""1""'""-'l:::r:.l "" IJ'l:.F<>"-~""" PER SECI'CIRI(+i..:::-5'}](+ I-3')1 ~~ --m·~~·.---o7.t'o ... cxwc ~SOUTHEAST I:I.!T CT N/A 72¥Lx1U:W17.1:D 4~0[ !50'--0" [ 8'-D' [ 7/8' ~ 72¥L&1UI W&7.1 D +4RET AI..PH'4 12.t'LIII.II'WI7.1'D CABLES ~ 12.9'L•11.9'Wx7.1'D 4-CXW< ~ 240" cr N/A =~:;:~::~:::~ !~/l!!'-D'/11'-D' I 7/B' BErM 12.t'LxiU'Wx7.1'D CABiS ~~ 72.1'Lx1U'W•7.1' 4CXWC etu.z NORTH Ia' cr N/A n.e:Lx\Ul:Wx7.1:D 4 ~,~~'-0'IB'-D'I7/B' w.3 7:1..11 L•IU W•7.1 D-+ 4 RET 12.t'L•11.i'WI7.1'D CABLES I<!~DISH T.B.D. 4'-fi'DWIEIER 4()'.,.,o-_LI/1> NOTE: SEE SHEU A-2 FOR ANI'£NNA PLAN AT tW.IW. SEClOR \ ~ cY 0 .// ) /./ / /'"/~ ,. ~ ~ 0 ~~IENNA PLAN 'A' ~~"' ANTENNA PLAN NOlES: ¢> :~~,J;~W.~~~R~~ FINISHED TO MATCH PROPOSED STUCCO FINISH <t> PROPOSED 4 x + RF TRANSPARENT FIBERC!.ASS TUBE FRAMING (SHOWN SHADED){m'IOO.) 4> PROPOSED 414 RFTRANSPAR£N1' FIBERGLASS TUB£ BRACE <$> PROPOSED W0C0 POST ~ PROPOSED4x12SLEEPER (SHOWN SIWlED) <§} =~~~~ENT~~~)IoiOUNTEDBEHIND <2> PROPOSED VERIZON W11ELESS RRU MOUNTED BEHIND PROPOSED ANTENNA (l'I'PICAL) ~ PROPOSED RAYCAP DC SURGE PRCr!ECT10N UNIT UNISTRVf I.IOUNTED TO SCREEN WALL <8> PROPOSEDCOAXCA81..ETRAYON4K4Pv'CSI..EEPERS ~ PROPOSED COAX CABLE TRAY MOUNTED TO SCREEN WALL (SHOWN DASHED) 4)> EXISllNG BUILDING EXTERIOR WALL BEI.CW (SHOWN twlHED) 4) EXISllNG ARCHITECTURAL CORNICE 4) EXI5nNG PAIW'EI" WALL. 4) EXISllNG BUILT-UP ROOF ~ EXISTlNGSTRUCTURALBEARINGWALLBELOW (sHOWN CASHED) 4) PROPOSED 'TRAF-WALK' PADS (TYPICAL) qp 5~E.~~F£~gj~G FINISH TO MATCH EXISllNG BUILDING 4) EX15nNG WOOD POST (T'1'PICAL) 4) EXISllNG SLEEPER (TYPICAL) ~ PROpOSED ARCHITECTURAL FtW1 CORNICE ABOVE (SHOWN DASHED) q) EXISllNC WOOD BRACE TO REMAIN ('TYPICAL) ~ PROPOSED W000 BRACE fOR NEW St:REEN HEIGHTEXT£NSION(1YPICN..) ~ EXISI1Na WOOD BRACE TO BE RDIOVED (SHOWN CASHED) ~ EXISllNG ROOFEl..EClRICAL ~EXISllNGSK'fUGHT 4) EXIS11NG ROOF AIR CONOrrlONER 4) EXISTING SIGN TO BE RE1o10VED AND RELOCATED. LANDLORD TO DEJERMit£ NEW LOCATION CUP 16-02 .. ANTENNAS AI-M AZit.llffi-1 120' ~/ ,. _./ / / / ,_.. \ 4) PROPOSED RAYCAP DC SllRGEPROTECTlON UNIT PIPE MOllNTEO TO UNISIRUT ~ PROPOSED lmUl'f CONDUIT ROUTING ON4x4PVCSLEEPERS ~ PROPOSED UNISTR1JT {SHOWN DASHED) Q) EXISllNG UGKTAXTURE t.IOUNTED ON PAIW'Er TO BE RELOCAlEO (COORDI~TE WITH OWNER) ~ EXISTING ROOF MA15 {SHOWN DASHED) 4} EXtsnNG ROOF PL.ATFORI.I ~EXISllNGSOI.ARTUBE ~EXlSllNGSA.TELUTEDISH -Boom g_ =CUAKEl_ I'I~CHITECTU~E :: INCORPORI'ITEO ======== PREPARED toR verizonJ P.O. BOX 19707 !RV!NE, CA. 92623-9707 (949) 286-7000 ===··=== APPROVALS DATE ~ DATE ~ EE/!N ~ DATE EE/OUT PROJECT NAME CARLSBAD VILLAGE 3150 PlO PICO DRIVE CARLSBAD, CA 92008 SAN DIEGO COUNTY ===··=== DRAWING DATES IJ9/15/15 91J"ZO(u) D9/22/15 \OO"ZD(sa) 10/02/15 \OD"ZDI!EV!SIONI 10/115/15 100"Z0REVISION2 11/30/15 100"ZDREVI510N3 12/07/15 10D"Z0REVISION4 12/10/IS :gg~ lg :i::l:g:: r ti:Z/D1/16 02/10/1& \OD"ZOREVISION7 u 03/01/1$ \OD"ZDREV\SION!I" D3/D7/16 IOO"ZDREVISION9 a• DS/D2/16 \OO"ZDREVISIONIO ••:. ===··=== SHEET TITLE ANTENNA PU\NS ===··=== PROJECTS\VERIZON\1.4025 ===::=== A-3 SOUTH ELEVATION IIW.!:W'oo1'G' WEST ELEVATION .,. ..... , .... ~ PROPOSED 4 X 4 RFTAANSPARENT FIBERGLASS TUBE FRAMING(rYPICAL) PROPOO£D UNISTRUT(NP,) CUP 16·02 B.EVATION NOTES: ~PROPOSEDRfTRNIISPARENTSCREEN. RFTRANSPAREHTSCREENMATERIALTO!AATCH PROPOSED STUCCO f\~\SH (SHOWN SHADED} ~ EXISllNG WOOD SCREEN, RDIOVE EXIsrlNG CEDAR WOOD PANElS AND REPLACE: WI1H SlUCCO FINISH TO MATCH EXISTING BUILDING <g:> EXISTING BRICK IJENEEI'( fiNISH ~EXISllNGsnJCCOFlNISH <€> EXtsllNG WINDOW (IYPIC.l.L) ~EXISTlNG~(rYPIC.l.L) <l> EXISTING WROUGHT IRON FENCE <!) EXISTING CONCREtE BLOCK WALL ~ ~~~~~ ~R~IS~:~ EXISTING BUILDING STliCCO ~~~=~~~ir~N 4} EXISTlNG SIGN TO BE REMOVED AND ~TED. I..N<IDLCRD TO OCTERidiNE NEW LOCATION 4}> EXISllNG DOWNSPOUT ~PROPOSED REI.OCATIONOI"EXISTING UGHT FIXTURE: t.IOUN'fED ON PNW'ET oq) EXISTJNG WOOii 1Rii.i io.i i"Oi' Cf O:lSTlt{G :.JECI-'A"l!C.~.L SCREEN TO BE REMOVED (SHOWN DASHED) 4} :o~~~~~~&o~~~~ ':Jl: AN COLOR TO MATCH EXIS11NG ARCHlTECTURAL CORNICE 4)> EXISTING MCHITEC'TURAL CORNICE ......,...samcN EXISTING ROOF '""""' ~L& 1HCHITECTURE :: INCO~PO~ATEO (760) ~H-HH ===··=== PREPARED F'OR verizonJ P.O. BOX 19707 IRVINE, CA 92623-9707 (949) 286-7000 ===··=== APPROVALS ~ DATE ~ c;m-- EE/OUT ~ PROJECT NAME CARLSBAD VILLAGE 3150 PIO PICO DRIVE CARLSBAD, CA 92008 SAN DIEGO COUNTY ===··=== 09/15/HI 09/22/15 10/02/15 10/05/15 11/30/15 12/07/15 12/10/15 02/01/1& 02/10/1& 03/01/1& 03/07/IB 05/02/1& DRAWING DATES 90"ZO(n) 100" ZD (u) IOOXZORE:VIStcN1 1t!CXZDR[\/ISION2 100"ZDR[\/ISION3 1DD"ZDR[\/ISIDN4 \OOXZOR[\/ISIDNS 100XZOR[\/1510NB 100XZ0R[IIISION7 ~gg: ~g =~l~lg~ : ~=; 1DDXZDRE:VISION1Dtoe: ===··=== SHEET TITLE EXTERIOR ELEVATIONS ===··=== PROJECIS\VERIZON\1-4025 ===n=== A-4 ~~!~~WJJ(U.Cilii\ NORTH ELEVATION 1115.-40' K-o" I 80.40' EAST ELEVATION IQN.I:W•NI' PROPOSED VERilON W!Ra..ESS ANTENNAS MOI..NTED BEHIND NEW RF TRANSPARENT SCREENS ON ROOF' OF EXISTING BUILDING ~ PROPOSED 4 x + RFTIWOSPARENT FlBERGI..ASSTUBE f'R.WING(TYPICAL) CUP 16-02 B.EVATION NOTES: <j;> PROPOSED RF l!WISPARENT SCREEN, RF 'JRANSPARENT SCREEN MATERIAL TO MA.1CH PROPOSED STUCCO flNISH (sHOWN SHADED} ~ EXIS'TlNG WOOD SCREEN, RENOVE EXISTING CEDAR WOOD PANElS AND REPLACE WITH SlUCCO FINISH TO W.TCH EXISTING BUILDING 4> EXIS'TlNG BRICK VENEER FIN$~ ~ EXtS'llNG STUCCO FINISH ~EXISTING WINDOW (tYP\Cf.L) ~ EXIS'TlNG DOOR (TYPICAI.J <2> EXISTING WROUGHT IRON FENCE ~ EXIS11NG CONI:aEJE BUlCI( WALl \9) b~~~~~R~s~:~ EXISTING BUILDING ST\JCCO ~ ~~~=~lSII~~~N ~ EXISllNG SIGN TO BE REMOVED AND RELOCAml. t.»lOLCRD TO oe:TERt.<IINE NEW LOCATION 4} EXISTlNG DOWNSPOUT 4) PROPOSED UTlUTY CONDUIT W:OUtmD TO WALL. PAINT TO W.TCH AO.IACfNT WAU. SURFACE COLOR (Y ~~G ~~ ~~ 1~~~~~l!:J:f~)I.IECHANICAL ~ ~~~~~N~~~~~~ ~ ~ COlOR TO W.TCH EXISTlNG ARCHrrEClURAL CORNICE 4) EXISTING MCHITECTURAL CORNICE ~ PROPOSEDWJ!IZONWIRELESSMANUAL 1RANSI'ER SWITCH AND G£NOOTOR RECEPTAClEt.IOUNTEDTOWAU... ~ EXISTlNQ WOOD GATE, REBUILD TO NEW SCREEN EX1ENSION HEIGHT. PAINT TO MATCH PROPOSED snJCCO FINISH """"""8ECT10H EXISllNG ROOF ""'""" ~J!hz& ll~CHITECTU~E :: INCOP.PO!IATED ======== PREPARED F'OR verizon" P.O. BOX 19707 IRVINE, CA 92623-9707 (9'49) Z88-700D ===··=== APPROVALS ~ ~ DATE ~ ~ DATE E£/OUT ===== OATE PROJECT NAME CARLSBAD VILLAGE 3150 P10 PlCO DRIVE CARLSBAD, CA 92008 SAN DIEGO COUNTY ======== 09/IS/HI 09/ZZ/15 10/0Z/15 10/05/15 11/JD/15 12/07/15 12/10/15 O:Z/01/18 OZ/10/16 OJ/01/16 03/07/18 05/0Z/16 DRAWING DATES 9D"Ztl(n) IOD"ZO{ .. ) 100"ZOREVI510N1 100"ZDREVISION:Z 100"ZDREVISIONJ l!lOXZDREVISION<I 1DOXZDREVISIOM5 \OOXZDREVISIOM6 \DO"ZDREV1510N7 \DO" ZD Rtv\5\0M & t" IODXZDREVIS\ON9 •• \OOXZOREVISION\0 ••: ===··=== SHEET TITLE EXTERIOR ELEVATIONS ===··=== PROJECTS\VERIZON\I<IO:ZS ======== A-5 OWNER'S NAME: WATERS EDGE PROPERTIES llC ASSESSOR'S PARCEL NUMBER(S) 20s-02o-Jo-oo BASIS OF BEARINGS: (NAD 83; Epoch 2010) THE BEARINGS SHOWN HEREON ARE BASED ON NAD 1983 CALIFORNIA STATE PLANE COORDINATE SYSTEM -ZONE 6. AS DETERMINED BY G.P.S, OBSERVATIONS, USING TRIMBLE 5700/5800 RECEIVERS AND TRIMBLE GEODETIC OFFICE 1.60 SOFTWARE. BASIS OF ELEVATIONS: NAVD 1988 ELEVATIONS ARE BASED ON GPS OBSERVATIONS FROM TWO NATIONAL GEODETIC SURVEY C.O.R.S. REFEREi-!CE STATiONS: 1) PLOS, ELEVATIOI-1 ~o~Uc?~o~~ A~Pcll~g· ELEVATION = 237.75' WITH GEOID 2012 FFMA FlOOD ZONE PES!GNAJJON· Notional Flood Insurance Program; County: Son Diego Effective Date: 5/16/2012 Mop/Panel: 05073C0762G The Flood Zone Designation for this site is: ALSO EXCEPTING FROM SAID LOT 3, THAT PORTION DESCRIBED AS FOLLOWS: BEGINNING AT THE INTERSECTlON OF lHE SOUlHWESTERLY LINE OF SAID LOT 3 WITH THE NORTHWESTERLY LINE OF LOT 4 IN BLOCK 79 OF CARLSBAD, ACCORDING TO MAP THEREOF NO. 365, fiLED IN lHE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, FEBRUARY 2, 1887; THENCE ALONG THE NORTHWESTERLY LINE OF SAID LOT 4, NORTH 55' 27' DO" FEET; THENCE AT RIGHT ANGLES, NORTH 34' 33' 00" WEST, 8.00 FEET; THENCE AT RIGHT ANGLES SOUTH 55" 27' DO" WEST, 47.00 FEET TO THE SOUTHWESTERLY LINE OF SAID LOT 3; THENCE ALONG SAID SOUT11WESTERL Y LINE, SOUT11 34' 33' 00" EAST, 8. DO FEET TO 1HE TRUE POINT OF B[GINNING PARCEL2: TilLE REPORT NOTES· NO EASEMENTS ARE LISTED ON SAID TITLE REPORT. ""'""y ,:-1-// 0/ // ' ' / \ }: I ;/ \ ., \ ' ' POKEY MAST APN:205-020-29-00 ., \ ~ \ \ \ \ I \ I \ I \ ' ' \ WATERS EDG-E PROPERTIES LLC APN:205-020-30-00 \ I ~\ ol "\ '6 a ?n\ I ' ' \ \ STJOHN APN:205-020-3t-OO I \ I \ / I ~// SCANLON APN:205-020-32-00 / / LEGEND These standard symbols will beloundinthedrowing. ~ ------BOUNDARY UNE -----CENTERLINE MISC. PROPERTY LINE ~liSC. TIE LINE RIGHT -OF -WAY LINE - - - - -EASEMENT LINE --X --FENCE LINE 4) Field survey completed on AUGUST 11, 2015. -BOOTH & =bUA.REZ_ 111\CHITECTUI\E :: PLANNING ~ VerJZROWIRELESS 15505 SAND CANYON AVENUE IRVIN.E,CA9261B BUILDING '0' 1ST. FLOOR ~~~~.~~~ ~·-~·~ DAF DATE REVISIONS I'.IB/15/15 SITE SURVEY ~ FLOYD SURVEYING 34005 GALLERON STREET TEMECULA, CA 92592 (949) 200-0526 EMAIL: lsll!tllaydsurvaylng.com SITE NAME CARLSBAD VILLAGE-VIKING SITE ADDRESS 3150 PIO PICO DRIVE CARLSBAD, CA 92008 SHEET TITLE SITE SURVEY GENERAL INFORMATION SHEET NUMBER LS1 I !\ I I ~~. \ I \':'!.. I' \t ~· \ I I I \ I \ I I \ I \ I I \ 6\ I I \ I I \ 1', 1\ % ~I RFPA iii7.i0 I \ I \ I I \ ' ' \ \ ~ 9065 -v+ N~~80.54 ~+ . / ' ,~. cy; " \,-' :,':; ~+ ~ 'C,'\ / '~~ ----,,)'"" STJOHN APN.205-020-3t-OO ' ' \ v ,\,·o. ""· . ~'?.>. ' \ SCANLON APN: 205-020-32-00 fl c c LEGEND These standard wdl befoundinthe -E --BOUNDARY LINE --CENTERLINE -----MiSC. PROPERTY LINE ---------MISC. TIE LINE -----RIGHT-OF-WAY LINE -EASEMENT LINE --FENCELINE LEGEND 4) Field survey completed or. AUGUST 11,2015. NOTES -Boom & =oumz_ ~1\CH ITECTU RE :: PL/1 f1NING "'""'" >I OOOT~ ''O"ITEOT •cO<., 0 '"''"· •nCHOT!Cf •oom "11. "'""'"c•. ,.o,. (>oo)"'""" ~ VerfZ9!JWIRELESS 15505 SAND CANYON AVENUE IRVINE,CA92618 BULLDit.lG '0'1ST. FLOOR DAF REVISIONS SITE SURVEY ~ FLOYD 34::0~ ~~E;O~~S~~T TEMECULA, CA 92592 (949) 200-0626 EMAil-: fsll!)floydsurveyTng.com SITE NAME CARLSBAD VILLAGE-VIKING SITE ADDRESS 3150 P\0 PICO DRIVE CARLSBAD, CA 92008 SHEET T1TLE SHEET NUMBER LS2