Loading...
HomeMy WebLinkAbout2017-04-05; Planning Commission; ; CT 15-04(A)/RP 15-06(A) (DEV15-028) – THE GRAND MADISON The City of Carlsbad Planning Division A REPORT TO THE PLANNING COMMISSION Item No. Application complete date: February 9, 2017 P.C. AGENDA OF: April 5, 2017 Project Planner: Shannon Werneke Project Engineer: Steve Bobbett SUBJECT: CT 15-04(A)/RP 15-06(A) (DEV 15-028) – THE GRAND MADISON – Request for approval of a Tentative Tract Map Amendment and Major Review Permit Amendment to modify a previously-approved four-story mixed use building to replace eight (8) professional office condominiums on the second and third floor with seven (7) additional residential condominiums. The resulting total number of residential condominiums proposed would be increased from four (4) to eleven (11). The 0.32-acre project site is addressed as 725 Grand Avenue, and located within Land Use District 1, Carlsbad Village Center, of the Village Review (VR) Zone and Local Facilities Management Zone 1. The project qualifies as a CEQA Guidelines Section 15332 (In-Fill Development Projects) Class 32 Categorical Exemption. I. RECOMMENDATION That the Planning Commission ADOPT Planning Commission Resolution No. 7237 APPROVING Tentative Tract Map Amendment CT 15-04(A) and Major Village Review Permit RP 15-06(A) based on the findings and subject to the conditions contained therein. II. PROJECT DESCRIPTION AND BACKGROUND Project Site/Setting: The 0.32-acre project site is comprised of one legal parcel located on the southeast corner of Grand Avenue and Madison Street, addressed as 725 Grand Avenue (APN 203-303-21). The subject property also abuts the Madison Street public alley to the east. The project site is located within Land Use District 1, Carlsbad Village Center, of the Village Master Plan, and is located outside of the coastal zone. Table 1 below identifies the General Plan designations, zoning and current land uses of the project site and surrounding properties. TABLE 1 – SURROUNDING LAND USES Location General Plan Zoning/Land Use District in Village Master Plan Current Land Use Site Village (V) Village Review (V-R)/ Land Use District 1 Dental office North Village (V) Village Review (V-R)/ Land Use District 1 Grand Avenue, private parking lot, Grand Avenue Bar and Grill South Village (V) Village Review (V-R)/ Land Use District 1 Blue Ocean restaurant East Village (V) Village Review (V-R)/ Land Use District 2 Madison Street alley, The Grand professional office building West Village (V) Village Review (V-R)/ Land Use District 1 Madison Street, Chase bank 3 CT 15-04(A)/RP 15-06(A) (DEV 15-028) – THE GRAND MADISON April 5, 2017 Page 2 Background: October 7, 2015, Planning Commission Resolution No. 7125 Planning Commission recommended approval of a Tentative Tract Map CT 15-04 and Major Review Permit RP 15-06 to demolish an existing 6,800 square foot (SF) dental office and construct in-place a 21,158 SF, four-story, 45-foot-tall (with architectural projection up to 60’), mixed use building, consisting of 4,600 SF of ground floor retail, eight (8) professional office condominiums located on the second and third floor, and four (4), two-bedroom/two-bath residential condominium units on the fourth floor, each with a rooftop deck. The project also included a request to purchase 23 in-lieu parking fees and the construction of an enclosed, at-grade parking garage with 20 parking spaces proposed to be accessed from the Madison Street public alley. November 17, 2015, City Council Resolution No. 2015-281 City Council approved Tentative Tract Map CT 15-04 and Major Review Permit RP 15-06 for the mixed use project. February 9, 2016, City Council Resolution No. 2016-023 City Council approved the request to purchase 23 in-lieu parking fees February 9, 2016 Grading Permit GR 16-04 issued for the demolition of the medical office building and the construction of the four-story mixed use building. September 23, 2016 Application submitted to amend CT 15-04 and RP 15-06. Although the grading permit remains valid, no work has occurred and the existing (vacant) medical office building remains onsite. The construction of the project has been put on hold in order to allow for the processing of the proposed amendments. Pursuant to the Section 21.54.125, the Planning Commission is the final decision-making authority for the subject amendments to the Tentative Tract Map and Review Permit. Project Proposal: The proposed project entails a request to amend the Tentative Tract Map and Major Review Permit to replace eight (8) professional office condominiums on the second and third floor of the four-story mixed use building with seven (7) additional residential condominiums, bringing the total number of residential condominiums proposed to eleven (11). The applicant has indicated that the project is financially infeasible without the proposed modifications. The proposed density of the project, 34.4 dwelling units per acre, is just under the maximum allowable density of 35 dwelling units per acre allowed pursuant to the Village Master Plan. No changes are proposed to the footprint of the building or the ground floor retail area, which remains at 4,600 square feet. Table 2 below provides a unit summary outlining the size and unit type proposed on each of the three floors. TABLE 2 – UNIT SUMMARY Floor Level No. of Units No. of Bedrooms/Bathrooms Size 2 4 Two, 3 bed/2 bath Two, 1 bedroom+ den/1 bath 1,157 SF to 1,653 3 3 Two, 3 bed/2 bath One, 2 bed/1 bath 1,385 SF to 2,084 SF 4 4 Four, 2 bed/2 bath 1,258 SF to 1,484 SF CT 15-04(A)/RP 15-06(A) (DEV 15-028) – THE GRAND MADISON April 5, 2017 Page 3 As discussed above, the original project included approval for the purchase of 23 in-lieu parking fees through the Village Parking In-Lieu Fee Program. The change in use from professional office to residential results in an overall reduction in the required number of parking spaces which are approved to be purchased from 23 to 12 spaces. Because the number of spaces which require in-lieu parking fees is being modified, the project is conditioned to receive approval from the City Council for the purchase of 12 in- lieu parking fees. The proposal to construct 11 residential condominiums results in the requirement to construct two (2) inclusionary (i.e., affordable, rent-restricted) housing units. In-lieu of restricting two of the 11 units as inclusionary units, the applicant submitted a request to the city’s Housing Policy Team to purchase two affordable housing credits within the Tavarua senior affordable housing project. On February 23, 2017, the City’s Housing Policy Team recommended approval of the above-noted request. With exception to some exterior changes, the contemporary architectural theme of the proposed 45-foot- tall mixed use building remains largely the same when compared to what was originally reviewed by the Planning Commission and approved by the City Council. Permissible architectural projections include a 3’-6” projection for the parapets, as well as the guard rail/safety fence for the roof-top deck, a 9’ projection for the stairwell and a 15’ projection for the elevator shaft. The tallest projection, the elevator shaft, is proposed at a height of 60 feet. To address the proposed change in use from professional office to residential condominiums on the second and third floor, the applicant has made the following changes to the exterior of the building:  Removal of the large storefront element at the corner of Grand Avenue and Madison Street; replaced with a warmer composite wood, stucco and glazing treatments similar to the adjacent eastern portion of the building. This represents the largest change to the exterior of the building.  Addition of a natural stone base and cap to the entire perimeter of the building;  Addition of notches in the parapet cap to break up the length of the linear parapet. An additional notch at floors 2-4 has been added near the northeast corner of the building;  Pulled back the southwestern enclosed elevator lobby farther away from Madison Street and modified to an open lobby containing balconies similar to the residential unit balconies;  Reduced the height of the western parapet to the minimum guardrail height (42") required above the 45'-0" roof height;  Reduced the height of the decorative composite wood guardrail along Grand Avenue to the minimum guardrail height (42") required above the 45'-0" roof height;  Reduced the height of the elevator/stair penthouse to the minimum height required by the elevator manufacturer. All elevator equipment is located in the elevator equipment room on the first floor and not within the elevator penthouse. Pursuant to information provided by the applicant, the manufacturer recommendations require that the elevator contain a hoist beam located at 12'-7" above finish floor for elevator installation purposes. This hoist beam is required to be an 8" deep beam and requires a 4" gap between the roof framing and the beam. The elevator penthouse design minimum height includes the hoist beam height, beam depth, beam gap, roof framing and required roof slope; and  Refined the paint colors to compliment the proposed residential use. Aside from recreational and open space amenities in the form of roof decks (912 SF to – 1,295 SF) for each of the four residential units on the fourth floor, an interior landscaped courtyard is proposed on the second floor, which includes a large seating area, landscape planters and enhanced flooring. The third and fourth floors are oriented in the same configuration as the second floor and will overlook the planter and common area on the second floor. A 165-217 SF enclosed storage area is also proposed as an amenity for each of the residential units. CT 15-04(A)/RP 15-06(A) (DEV 15-028) – THE GRAND MADISON April 5, 2017 Page 4 III. ANALYSIS The proposed project is subject to the following ordinances, standards, and policies: A. Village (V) General Plan Land Use designation; B. Village Review (V-R) Zone (C.M.C. Chapter 21.35), Land Use District 1 - Carlsbad Village Center (Village Master Plan and Design Manual); C. Inclusionary Housing Ordinance (C.M.C. Chapter 21.85); D. Subdivision Ordinance (C.M.C. Title 20); and E. Growth Management Ordinance (C.M.C. Chapter 21.90), Local Facilities Management Plan Zone 1. The recommendation for approval of this project was developed by analyzing the project’s consistency with the applicable regulations and policies. The project’s compliance with each of the above regulations and policies is discussed in the sections below. A. Village (V) General Plan Land Use Designation The subject property, comprising one legal parcel, has a General Plan Land Use designation of Village (V). As discussed in the Village Master Plan, properties within the Village Area do not have an assigned residential density as it relates to Growth Management Plan compliance. Therefore, the minimum and maximum densities for residential development are established in the Village Master Plan. Table 3 below identifies the permissible density range for properties located within Land Use District 1. TABLE 3 – PROJECT DENSITY Gross Acres Net Acres Allowable Density Range Project Density 0.321 ac Same Density Range: 28-35 du/ac 28 du/ac = 9 units 35 du/ac = 11 units 11 units/0.32 ac = 34.4 du/ac As identified above, the project’s density of 34.4 dwelling units per acre falls slightly below the maximum allowable density of 35 dwelling units per acre and therefore complies with the allowed density for Land Use District 1. Pursuant to the Housing Element of the General Plan, because a Growth Management Control Point has not been established for residential development in the Village, all residential units approved in the Village must be withdrawn from the City’s Excess Dwelling Unit Bank. The City’s Excess Dwelling Unit Bank is implemented through City Council Policy No. 43. Pursuant to City Council Policy No. 43, an applicant for an allocation of dwelling units shall agree to provide the number of inclusionary units as required pursuant to C.M.C. Section 21.85.050. As discussed in Section C below, the applicant’s proposal to purchase the requisite two (2) affordable housing credits is supported by the city’s Housing Policy Team. In approving a request for an allocation of excess dwelling units, the project shall meet the findings identified in City Council Policy No. 43. Specifically, the project location and density shall be found to be compatible with adjacent land uses and applicable provisions of the General Plan and other applicable planning documents. As discussed in the attached Planning Commission Resolution No. 7237, the proposed project meets these findings. CT 15-04(A)/RP 15-06(A) (DEV 15-028) – THE GRAND MADISON April 5, 2017 Page 5 Table 5 below describes how the proposed project is consistent with the various elements of the Carlsbad General Plan. TABLE 5 – GENERAL PLAN COMPLIANCE ELEMENT GOAL/POLICY COMPLIANCE WITH GOAL/POLICY Land Use Goal 2-G.29 Maintain the Village as a center for residents and visitors with commercial, residential, dining, civic, cultural, and entertainment activities. Goal 2-G.30 Develop a distinct identity for the Village by encouraging a variety of uses and activities, such as a mix of residential, commercial office, restaurants and specialty retail shops, which traditionally locate in a pedestrian–oriented downtown area and attract visitors and residents from across the community by creating a lively, interesting social environment. Policy 2-P.70 Seek an increased presence of both residents and activity in the Village with new development, particularly residential, including residential as part of a mixed- use development, as well as commercial, entertainment and cultural uses that serve both residents and visitors. The proposed project provides a mix of residential and commercial/retail uses at an appropriate location within the Village (Carlsbad Village Center Land Use District No. 1). The mixed use building will contribute toward the enhancement of the Village center and will encourage greater residential support opportunities. With the increase in the number of residential units and commercial/retail opportunities in the core of the Village, the project assists with the creation of a lively, interesting social environment. The project reinforces the pedestrian- orientation desired for the downtown area by providing the new residents an opportunity to walk to shopping, recreation, and mass transit functions. Further, the project’s proximity to existing bus routes and mass transit (i.e., ¼ mile) will help to further the goal of providing new economic development near transportation corridors. Overall, the new residential units will enhance the Village as a place for living and working. Housing Goal 10-G.3 Sufficient new, affordable housing opportunities in all quadrants of the city to meet the needs of current lower and moderate income households and those with special needs, and a fair share proportion of future lower and moderate income households. Goal 10-P.15 Pursuant to the Inclusionary Housing Ordinance, require affordability for lower income households of a minimum of 15 percent of all residential ownership and qualifying rental projects. Policy 10-P.18 The City’s Housing Policy Team reviewed the proposed project and recommended the applicant purchase two inclusionary (i.e., rent and income-restricted) housing credits in the Tavarua Affordable Housing Project to fulfill the project’s affordable housing requirement. The project has been conditioned to require the approval of an Affordable Housing Agreement prior to recordation of the final map. In approving a request for an allocation of excess dwelling units, the project shall meet the findings identified in City Council Policy No. 43. Specifically, the project location and density shall be found to be compatible with adjacent land uses and the project is consistent with the General CT 15-04(A)/RP 15-06(A) (DEV 15-028) – THE GRAND MADISON April 5, 2017 Page 6 ELEMENT GOAL/POLICY COMPLIANCE WITH GOAL/POLICY Adhere to City Council Policy Statement 43 when considering allocation of “excess dwelling units” for the purpose of allowing development to exceed the Growth Management Control Point (GMCP) density, as discussed in Section 10.3 (Resources Available). With limited exceptions, the allocation of excess dwelling units will require provision of housing affordable to lower income households. Plan and any other applicable planning document. As discussed in the attached Planning Commission Resolution No. 7237, the proposed project meets these findings. Mobility Goal 3-G.1 Keep Carlsbad moving with livable streets that provide a safe, balanced, cost- effective, multi-modal transportation system (vehicles, pedestrians, bikes, transit), accommodating the mobility needs of all community members, including children the elderly and the disabled. Goal 3-G.3 Provide inviting streetscapes that encourage walking and promote livable streets. Policy 3-P.5 Require developers to construct or pay their fair share toward improvements for all travel modes consistent with the Mobility Element, the Growth Management Plan, and specific impacts associated with their development. The proposed project) will have a net gain of 18 average daily trips (ADTs); the net gain factors into account the demolition of the existing medical office building. The project is consistent with the city’s Growth Management Plan. In addition, the proposed project has been designed to meet all of the circulation requirements, which includes but is not limited to, curb, gutter and sidewalk, where appropriate, and improving the Madison Street Alley frontage. The project site is located approximately ¼ mile from the train/Coaster station which provides service throughout the day. The project’s close proximity to the transit stop will provide residents with the opportunity to commute to major job centers, thereby reducing vehicle miles traveled (VMTs) and the carbon footprint. Further, the mixed-use project supports walkability and mobility by locating the project near existing goods and services. Public Safety Policy 6-P.6 Enforce the requirements of Titles 18, 20, and 21 pertaining to drainage and flood control when reviewing applications for building permits and subdivisions. Policy 6-P.34 Enforce the Uniform Building and Fire codes, adopted by the city, to provide fire protection standards for all existing and proposed structures. The proposed structural improvements are required to be designed in conformance with all seismic design standards. In addition, the proposed project is consistent with all of the applicable fire safety requirements. Further, the project has been conditioned to develop and implement a program of “best management practices” for the elimination and reduction of pollutants which enter into and/or are transported within storm drainage facilities. CT 15-04(A)/RP 15-06(A) (DEV 15-028) – THE GRAND MADISON April 5, 2017 Page 7 ELEMENT GOAL/POLICY COMPLIANCE WITH GOAL/POLICY Policy 6-P.39 Ensure all new development complies with all applicable regulations regarding the provision of public utilities and facilities. Noise Goal 5-G.2 Ensure that new development is compatible with the noise environment, by continuing to use potential noise exposure as a criterion in land use planning. Policy 5.P.2 Require a noise study analysis be conducted for all discretionary development proposals located where projected noise exposure would be other than “normally acceptable.” The project site is located approximately ¼ mile east of the train station. The proposed project is consistent with the Noise Element of the General Plan in that the project has been conditioned to comply with the recommendations of the noise analysis report (Birdseye Planning Group, December, 2015) to ensure that the proposed building design adequately attenuates the noise levels for the new condominiums. The windows of each unit will need to be closed to meet a 45 dB(a) CNEL interior noise level. Therefore, mechanical ventilation is required. In addition, the project is conditioned to comply with the construction requirements of the aforementioned noise study. B. Village Review Zone (C.M.C. Chapter 21.35), Land Use District 1 – Carlsbad Village Center (Village Master Plan and Design Manual) The subject property is located within Land Use District 1 – Carlsbad Village Center of the Village Master Plan. Pursuant to the Village Master Plan, mixed-use (commercial retail, professional office and residential uses) is a permitted use. No variances or standards modifications are being requested for the project. The specific development standards for new development within Land Use District 1 and the project’s compliance with these standards are shown in Table 6 below: TABLE 6 – VILLAGE MASTER PLAN, LAND USE DISTRICT 1 (CARLSBAD VILLAGE CENTER) STANDARD REQUIRED/ALLOWED PROPOSED COMPLY Front Yard Setback (Grand Avenue) No minimum; 10’ maximum for the first at grade floor. Setback areas not occupied by a driveway shall be landscaped and/or contain semi-public amenities such as courtyard or outdoor seating areas. Ground floor: 1’-2” to 30’-5’ 3/8“(**) Upper floors: 2’-8” to 25’-2“ **The northwest corner of the building is setback from the southeast corner of Grand Avenue and Madison Street to allow for the incorporation of a plaza, landscape planter and seating area. These features enhance the project and will activate the street corner. Yes CT 15-04(A)/RP 15-06(A) (DEV 15-028) – THE GRAND MADISON April 5, 2017 Page 8 STANDARD REQUIRED/ALLOWED PROPOSED COMPLY Side Yard Setback (Madison Street and south property line/elevation) No minimum or maximum Ground Floor: West (Madison St.): 1’-2” to 30’-5“ South: 1’ Upper Floors: West (Madison St.): 1’-1” to 25’-3¼“ South: 1’ to 36’ Yes Rear Yard Setback (Madison St. Alley) No minimum or maximum Ground Floor: 4’ Upper Floors: 3’ to 11’-3/4” Yes Open Space: 20% = 2,802 SF 72.9% (10,222 SF) Yes Open space may be public or private and may be dedicated to landscaped planters, open space pockets and/or connections, roof gardens/patios, balconies, other patios and outdoor eating areas. Landscape/Planters: 2,326 SF Private Balconies: 2,067 SF Common patio: 1,505 SF Roof Deck: 4,324 SF Building Coverage: 100% 87.1% Yes Building Height: 45’ maximum Roof line: 45’ Yes Pursuant to C.M.C. 21.46.020, the following project-related architectural features are considered allowed protrusions above height limits and are therefore exempted from the maximum building height standard: parapet walls, tower elements, guardrail, and elevator/stair shafts. Parapet walls/decorative guardrail: 45’ to 48’ Elevator shaft: 60’ Stairwell: 54’ CT 15-04(A)/RP 15-06(A) (DEV 15-028) – THE GRAND MADISON April 5, 2017 Page 9 STANDARD REQUIRED/ALLOWED PROPOSED COMPLY Parking Commercial Retail: 1 space per 300 sq. ft. of net floor area. 3,680 SF ÷ 300 sq. ft. = 12 spaces **Can be provided onsite or satisfied via the Village Parking In-Lieu Fee Program. Multi-family Dwellings (outside coastal zone): -2 spaces per two-bedrooms or more -1 space per one-bedroom units -For condominiums, at least one space must be covered. -Residential development must provide its parking onsite. Guest: No guest parking required for properties located outside of coastal zone Proposed project: 2, one-bedroom units 5, two-bedroom units 4, three-bedroom units 1 space x 2 units = 2 spaces 2 spaces x 9 units = 18 spaces Total Spaces Required: 12 + 20 = 32 spaces 20 spaces must be provided onsite for the residential units; at least one space per residential unit is required to be covered. 20 spaces provided in an enclosed, at- grade garage for the residential units. The balance of the required parking, 12 parking spaces, will be provided through the participation in the Village Parking In-Lieu Fee Program. Findings of support are discussed below and Planning Commission Resolution No. 7237. Yes Compact Parking A maximum 40% of the total number of parking spaces provided on-site may be constructed to meet the requirements of a small or compact vehicle. 40% x 20 spaces = 8 spaces 8 compact spaces proposed Yes CT 15-04(A)/RP 15-06(A) (DEV 15-028) – THE GRAND MADISON April 5, 2017 Page 10 As discussed in Table 6 above, the project proposes to satisfy a portion of its parking requirement to provide 12 parking spaces off-site through participation in the Village Parking In-Lieu Fee Program. The fees collected from the Village Parking In-Lieu Fee Program are deposited into an earmarked, interest- bearing fund to be used for construction of new, or maintenance of existing, public parking facilities within the Village Area. The current fee is $11,240 per required parking space to be provided off-site. The project site is located within Parking Zone 1 of the Village, which allows the developer to make an in- lieu fee payment for up to 100% of the on-site parking requirement if the property is located within 600 feet of an existing parking facility. The site is located within 300 feet of two (2) existing public parking lots which combined have a total of 110 parking spaces. As a condition of project approval, the applicant shall be required to enter into an agreement to pay the parking in-lieu fee prior to the issuance of building permits for the project. In order to participate in the Parking In-lieu Fee program, the appropriate decision-maker (City Council) must find that: 1. The proposed project is consistent with the goals and objectives of the Village Master Plan and Design Manual; 2. The proposed use is consistent with the land use district in which the property is located; 3. Adequate parking is available within the Village to accommodate the project’s parking demands; and 4. The In-Lieu Fee Program has not been suspended or terminated by the City Council. Justification for the above referenced findings is as follows: 1. The project is consistent with Village Review Master Plan and Design Manual in that the project assists in satisfying the goals and objectives through the following actions; 1) the mixed-use project stimulates property improvements and new development in the Village by constructing a new permitted mixed-use building in an area with a mix of dated buildings and increasing the intensity of development within the Village; 2) it establishes Carlsbad Village as a quality shopping, working and living environment by providing new employment opportunities; increasing the number, quality, diversity and affordability of housing units within the Village; and reinforcing pedestrian retail continuity within the Village commercial areas; and 3) improves the physical appearance of the Village Area by redeveloping an underutilized site along Grand Avenue and Madison Street with a new attractive building that adheres to the land use regulations and design guidelines set forth for the area. 2. The proposed use is consistent with the goals and objectives set forth for Land Use District 1 of the Village Master Plan and Design Manual in that the mixed-use development not only provides mutually supportive uses in the form of residential, professional office and commercial retail uses along Grand Avenue and Madison Street, but reinforces the pedestrian-orientation desired for the downtown area by providing new residents and employees an opportunity to walk to local shopping, dining, recreation, and mass transit functions; furthermore, its close proximity to existing bus routes and mass transit help to further the goal of providing new economic and residential development near transportation corridors; and lastly, it will contribute to the revitalization of the Village area in the form of a new building in the core of the Village; new commercial lease space, new employment opportunities and new consumers. 3. Adequate parking is available within the Village to accommodate the project's parking demands. Pursuant to the most recent Kimley Horn parking study dated November, 2016, the highest occupancy for all public parking lots combined in the Village was 62% at 1:00 P.M. in May on a weekend. This utilization ratio allows for continued implementation of the parking in-lieu fee program in that it is less than the 85% threshold for maximum utilization set by the City Council. CT 15-04(A)/RP 15-06(A) (DEV 15-028) – THE GRAND MADISON April 5, 2017 Page 11 4. The In-Lieu Fee Program has not been suspended or terminated by the City Council. Based on these findings, it is staff’s recommendation that the proposed project warrants granting participation in the Parking In-Lieu Fee Program for a maximum of 12 parking spaces. If the City Council grants participation in the Parking In-Lieu Fee Program the project will satisfy its parking requirement as set forth in the Village Master Plan. C. Inclusionary Housing For all residential development comprising seven (7) or more units, not less than 15% of the total units approved shall be constructed and restricted both as to occupancy and affordability to lower-income households. The proposal to construct 11 residential condominiums results in the requirement to construct two (2) inclusionary (i.e., affordable, rent-restricted) housing units. In-lieu of restricting two of the 11 units as inclusionary units, the applicant submitted a request to the city’s Housing Policy Team to purchase two affordable housing credits within the Tavarua senior affordable housing project. On February 23, 2017, the City’s Housing Policy Team recommended approval of the above-noted request. The two affordable housing credits are available for purchase from the Tavarua Affordable Housing project. As required by CMC Chapter 21.85, the project is conditioned to require the approval of an Affordable Housing Agreement by the City Council prior to recordation of the final map. D. Subdivision Ordinance The proposed project consists of the development of a four (4) story mixed use condominium project. Specifically, one (1) ground floor commercial unit, and 11 residential condominium units are proposed. As conditioned, the design of the proposed tentative tract map and the improvements are consistent with and satisfy the requirements of the General Plan, Village Master Plan, Titles 20 and 21 of the Carlsbad Municipal Code, and the State Subdivision Map Act. In addition, the design of the subdivision and the required improvements will not conflict with easements of record or easements established by court judgment, or acquired by the public at large, for access through or use of property within the proposed subdivision. All easements have been identified and none are affected by the proposed subdivision. E. Growth Management The proposed project is located within Local Facilities Management Zone 1 in the northwest quadrant of the city. The impacts on public facilities created by the project, and its compliance with the adopted performance standards, are summarized in Table 7 below. TABLE 7 – GROWTH MANAGEMENT COMPLIANCE STANDARD IMPACTS COMPLIANCE City Administration 38.25 sq. ft. Yes Library 20.40 sq. ft. Yes Waste Water Treatment 11 EDU Yes Parks 0.08 acres Yes Drainage 1.22 CFS/Basin A (Grand Avenue) 0.37 CFS/Basin B (Madison Street) Yes Circulation Existing: 272 ADT Proposed: 290 ADT Net increase: 18 ADT Yes CT 15-04(A)/RP 15-06(A) (DEV 15-028) – THE GRAND MADISON April 5, 2017 Page 12 STANDARD IMPACTS COMPLIANCE Fire Station 1 Yes Open Space N/A N/A Schools (Carlsbad) Elementary = 1.8788 student Middle = 0.9251 student High School = 0.8063 student Yes Sewer Collection System 2,983 GPD Yes Water 3,808 GPD Yes Properties located within the boundaries of the Village Master Plan do not have a Growth Management Control Point or an allocation for dwelling units. Pursuant to the Village Master Plan, based upon the gross 0.32 acres on the site, up to 11 residential dwelling unit may be built. Therefore, as 11 residential dwelling units are proposed, a total of 11 residential dwelling units are proposed to be deducted from the City’s Excess Dwelling Unit Bank. Pursuant to Planning Commission Resolution No. 7237, the allocation from the Excess Dwelling Unit Bank can be supported. IV. ENVIRONMENTAL REVIEW The City Planner has determined that the project belongs to a class of projects that the State Secretary for Resources has found not to have a significant impact on the environment, and it is therefore categorically exempt from the requirement for the preparation of environmental documents pursuant to Section 15332 (In-Fill Development Projects) Class 32 Categorical Exemption of the State CEQA Guidelines. The project is consistent with the General Plan, the Village Master Plan, and the Zoning Ordinance; the project site is within the City limits, is less than 5 acres in size, and is surrounded by urban uses; there is no evidence that the site has value as habitat for endangered, rare, or threatened species; approval of the project will not result in significant effects relating to traffic, noise, air quality, or water quality; and the site can be adequately served by all required utilities and public services. In making this determination, the City Planner has found that the exceptions listed in Section 15300.2 of the state CEQA Guidelines do not apply to this project. A Notice of Exemption will be filed by the City Planner upon final project approval. The mixed use project is not subject to Climate Action Plan measures because the project is below the screening threshold listed in the city’s Climate Action Plan (Section 5.3). ATTACHMENTS: 1. Planning Commission Resolution No. 7237 2. Location Map 3. Disclosure Statement 4. Correspondence from Imagine Carlsbad, dated March 9, 2017 5. Reduced Exhibits 6. Full Size Exhibits “A – T” dated April 5, 2017 GRAND AVCARLSBAD VILLAGE DROAK AVH O P E A V W A S H I N G T O N S T PINE AVST A T E S T M A D I S O N S T HOME AVJE F F E R S O N S TBEECH AVARBUCKLE PLR O O S E V E L T S T H A R D I N G S T CT 15-04(A) / RP 15-06(A)Grand Madison SITE MAP JPALOMARAIRPORTRD E L C AMREALL A COS TA AV C A R L S B A D B LCARLSBADVILLAGEDREL C AMINOREAL MELRO S E DRAVIARAPY RANCHOS ANTAFERDC OLLE GEBL!"^ SITE ~ .. (_City of Carlsbad DISCLOSURE STATEMENT P-1(A) Development Services Planning Division 1635 Faraday Avenue (760}602·4610 www.carlsb;dta.&ov Applicant's statement or disclosure of certain ownership interests on all applications Which will require discretionary action on the part of the City Council or any appointed Board, Commission or Committee. The following information MUST be disclosed at the time of application submittal. Your project cannot be reviewed until this information is completed. Please print. N~~-. . Person.is defln.ed a~ "Any lndlvldt.ia.l, firm, co-partner~hip, join_( venture. assocl;~!ion, social club, fraterna.l or,Qan~atioo,.cbrppratlon; estate, trust, ·receiver, syndicate, in this and ar:~y other cQunty,,clty an!1 cour:tl)i.' cily. mU~p;il(ty, illsl.f,lct or qlb~r poljtii:al su~diV1sJon or al)y .otl,ler. group or combl{lallQtl aclln~ as a.u.nft.. ~ · ~ge~ · m;y~~~n this docum~nti haw:e';e~:· ~~~ legal ·n~~~:=a:n~ ~~fi~ o'f ihe $P;tic~~·~nd p~perty. ~rter must be'pio~id\'!(1 below. . • . 1. APPLICANT (Not the applicant's agent) Provide the COMPLETE. LEGAL names and addresses of ill persons having a financial interest in the application. If the applicant includes a corporation or partnership, inClude the names, titles, addresses of all individuals owning more than 10% of the shares. IF NO INDIVIDUALS OWN MORE 111AN 10% OF THE SHARES, PLEASE INDICATE NON-APPLICABLE (N/A) IN THE SPACE BELOW. If a publicly-owned corporation, include the names, titles, and addresses of the corporate officers. (A separate page may be attached if necessary.) Person Corp/Part __________ _ Tille __________ _ Title. ____________ _ Address. _________ _ Adaress ___________ _ 2. OWNER (Not the owner's agent) P·1(A) Provide the COMPLETE. LEGAL names and addresses of ALL persons having any ownership interest in the property involved. Also, provide the nature of the legal ownership (I.e., partnership, tenants in common, non-profit, corporation, etc.). If the ownership Includes a corporation or partnership, include the names, titles, addresses of all individuals owning more than 10% of the shares. IF NO INDIVIDUALS OWN MORE THAN-1 0% OF THE .SHARES, Pl. EASE :INDIGA:Y:E .NQN-ARPLIGABLE (N/A) IN. THE 'SPACE BELOW. If a publicly~owned corooration, include the names, titles, and addresses of the corporate officers. (A separate page may be attached if necessary.) Person Patrick McGuire Corp/Part Patrick Smith LLC Title Manager Title_M_a_n_a~g;...e_r _________ _ Address PO eox 2.466, Car1sbad, CA. 92018 AddressPO Box 2466, Carlsbad; CA, 92018 Page 1 of 2 Revised 01110 3. NON-PROFIT ORGANIZATION OR TRUST If any person Identified pursuant to (1) or (2) above is a nonprofit organization or a trust, list the names and addresses of A!:£! person serving as an officer or director of the non- profit organization or as trustee or beneficiary of the. Nol"l Profrtffrust. ______ _ Non ProfrVTrust. ________ _ Title,_ _________ _ Title. ____________ _ Address. _________ _ Address ___________ _ 4. Have you had more than $500 worth of business transacted with any member of City staff, Boards. Commissions. Committees .and/or Council witbifl the past twelve (12) months? [ZJ Yes 0 No If yes, please indicate person(s}:_M_a_rk_P_a_ck_a_rd _____ _ NOTE: At1ach additional sheets if necessary. I certify tha,t all the above information is true and correct to the best of my knowledge. S?.~~~ qf.s.::/~'v Signature of applicanVdate ~~~~ 't'\\!G~~ Print or type name of 'OWi'l·ar Print 'Of type name of applicant Signature of owner/applicant's agent If applicable/date Print or type name of owner/applicant's agent P-1(A) Paga 2 of2 Revised 07/10 Memo TO: Carlsbad Planning Commissioners FROM. Imagine Carlsbad - Robert Wilkinson DATE March 9, 2017 RE: Re- Development Proposal for the Grand Madison in the Village The “Grand Madison” (GM) yes its back, unfortunately however it is not back in an attempt to get it right this time! This re-development project continues to propose a flawed development plan. Flawed to the point that we are asking you to vote no and give the applicant direction on what you would approve in a future application. This critic is the second we are providing to you for this hearing (please see 800 Grand) so I will try not to duplicate too many statements on the Village in general. That said, I will stress once more that we are requesting you to show leadership acting as our “Town Planner” in this time between old and new master plans. We now have the “Carlsbad Loft”(CL) a project most of us supported, as an example of what can be achieved in a mixed use development even in a “contemporary” styled building. Critic - Requests that should be made of the GM to receive approval; It needs to make a real response to be a transit oriented development (TOD). That it is within easy walking distance from our rail service. It should do this by placing the other form of transportation in the basement (sub street level). Since the property is a bit too small to efficiently use a auto ramp and since it has alley access, allowing for queuing it should use an auto lift. We believe auto lifts are an appropriate tool for TOD. In the fully approved CL street edge retail space provides double height ceilings in all the store front areas along CVD, GM does non of that. The CL’s building facade then steppes back along the street edge on the third and fourth levels, again the GM makes no attempt to do so even though it has a large area of its total building envelope unused on its southern area. This time the GM is making the pitch so typical for a mixed use project attempting to maximize the residential portion to the detriment of the other uses in the mix, street edge commercial. Yes again, it is town planning controlled by real estate speculation instead of sound principles that will produce a vibrant Downtown Village. Instead of this we ask for full depth commercial space on the street level 50-60ft then one or two levels of office space (original version of the GM) then residential use on top. Not what this project is proposing in this application. Then there is the “elephant in the room” I will try not to use the subjective tern “ugly” in my crit, The applicant has attempted to tone down the over the top version of contemporary styling in the original proposal however it continues to be a mess that lacks any attempt at warmth, creativity or character that is desired in the Village by our community . Page1of2 I believe all we need to do is to ask ourselves would be attracted to this building to see what is in side due to its appearance? It is our hope that even though none of you have any formal training in design you have now been at this long enough to answer the question of attraction. Yes you are out there on your own as the planning staff has owned up to the fact that they are not architects nor are they designers and have reached out to get professional help on this issue in the MP. As you consider all this, please remember we have all referred to the Village as a jewel a “diamond in the rough” and with each project we approve we chip away to reveal its luster. Approving this project would mean we do have not have a good hold of the hammer and chisel. The property sits at a prime location with the Village Core, on one of its main streets, Grand Ave, on a corner site with alley access. It would be the largest building on this important thoroughfare. A public right of way we hope to turn into the “Promenade” a pedestrian ramble that is in the draft MP. We have continued to pitch this linear open space at the City pushing for a demonstration project on two blocks between Roosevelt and Jefferson streets. The Village Association supports this action and hopes to move its Farmers Market, ever shrinking on State Street to the demonstration area on Grand. Meaning this weekly activity will take place directly in front of the GM, so everyone will have a up close pedestrian exposure to it. What will be their reaction yum or yuk? Thank you for your consideration of this input from the community. Page2of2 ...... -... --:f. ::~~;: ..... ... ---= :!:i::,e:' .. .... _ .... ::. ==== ... ..._ __ , __ .... -...... .. ~-lUlL ... __ .. -- THE GRAND MADISON MIXFD USE DEVILOPFMENT ---........ -- ------ :.-.u-.-...-.,. .. JIID. --"'='.::.-= ............ ...__ -·-.-...-...-..-----..--.-------·--..,.,.,_,., __ ----..---. --~----,_. ......... ._ ... __ ---------..... .-.. -- -·-------=----... " ---·--a • ------------------ ------!!!10!•• -· WIHI--=--=== • ___ ........ _ _.,. --- ---·-....... ............ _ .. ___ , ... ~ .. -.., ................ ,_...._.. ...... ...... " ·-~-··~.,.,.._:11_•_.,._. --WDIII-~ .... ------.............. ,., ............ ..,_ ... _,., ...... ----··-----.... .... ----·----... .... --------....... ,.,. ..... _ .__.,.... ............... ...... , ... ~ .... ---... --............... ~ .... -IIIJ.MI_II.M _,.__ ......... ... -·--. ........ ,., __ ....... -·"---. -----... ~ .. ~~--~~-=::.-··-......... ., . ..._ . ._._-.~ -rr.=~··---.... ....... __,. .... -~~~-----.._. ___ _ ---· -~-. ........ , .. ........ -~--·· ... ,., ..... _...u .._.IWIU_f*"_...U --- ---.... ._ ... _-. ... . .. ~ .. ... .... ... ... , .. ... ... ..,._,. ____ 'lllllllrtw..-...:tiiM-. ,.._ ... .u.._ ..... .......,._ ---......... ---.~~~-..,...----···· ____ ..._ c • ----·----... ·---·---.... ,.,_,.. ... ._ ......... _ ..... _.,..,,...._..._,..._,...,. ..... .-.......... .__ ............. . ... ........ _,... .................. ..... ,...,..._, ..,.. ............ __. ..... ,..,...,..,_ --_,.._ --------·-......... ---..-. _,_ ---~---.... --~----....... -------------- ..... _ .... ..... "'C ....... ...... "'C ..... _ .. _ •• ,., .... A._..._.,.__,. __ .'MIOII. -.. ·-·~-.............. __ ..... ~~~~~.--·~· .. ·~--· -· --- ---gjiiG .._...""" ......... -.--.. -..,.........._ _ _. gp:iu. APPROVED tiEll'nmAlftOft!D'JDirAm'lllfllllllllrll: JLIIMJIUL~liO-IatuaJUII" !fa._C.JUJIDD~ -.umll....___ Ill MAA Aocbitul1 IIIJIIII~nln,.ll!dU ~~:~~::::,I•T·III::;:;!,.:!~: ..,....._,...,_,._ --~---"" "" -t~---1 ..... ,__,....., ·~""'" ...... A,..-.....,... ·~--.... . .,.... ...... ~ --Tm.E Sl-fET --A0.1 .......... --_, .. ---::.::::.'1'.-=.--------.............. _. .................. -----··-................... . r ~<9 \ 1 1 l llj DETAIL FI.IM THROUGH PLNmRAT FL.OOR IE'IELS ""'"''"'""' SITE PIAN DETAIL FLOW THROUGH PlANTER AT GRADE '"""""" If "' APPROVED tiEll'nmAlftOft!D'JDirAm'lllfllllllllrll: JLIIMJIUL~liO....,.__IatuaJUII" !fa._C.JUJIDD~ -.mnl....___ ..,....._,...,_,._ --~---... "' -t~---1 ..... ,.__,....., ·~""'" ...... A,..-.....,... ·~--.... . .,.... ...... ~ -- --A1.1 REDUCED 5f1f PlAN APPROVED tiEll'nmAlftOft!D'JDirAm'lllfllllllllrll: JLIIMJIUL~liO....,.__IatuaJUII" !fa._C.JUJIDD~ -.mnl....___ ..___. ---- Ill MAA Arcbitul1 IIIJIIII~nln,.ll!dU ~~:~~::::,I•T·III::;:;!,.:!~: ..,....._,...,_,._ --~---...... -t~---1 ..... ,.__,....., ·~""'" ...... A,..-.....,... ·~--.... . .,.... ...... ~ --RBJIJaD SITE PIAN --A1.2 ~IALRI:TAIL 9,600 S.F. NfT • 4/JOO S.F. 6R056 • 11/M~ ~lllr.cl1611U:1Vlll 11-0' Ol!ll.lllt- -~---'-'"' _ .... -- I~ " 2 • .. .. "' lftJ/liH ... -' ~~~: ............. 1...,. • Ill IIAA Arcniltcl1 IIIJIIII~nln,.ll!dU ~~:~~::::,I•T·III::;:;!,.:!~: ..,....._,...,_,._ --~--­.......... -t~---1 ..... _III.JIIIa!IDIK.Z.,..... ·~""'" ...... A,..-.....,... ·~--.... . .,.... ...... ~ --RitST R.OOR PIAN --A2.1 l l'lMII:Il a t:l a ~ + -----11-.L.· / t ~'4 ~y ._. ..... ....,.. ---==-=---- GOI+'ON NlUt SECOND R.OOR. PIAN Ill MAA Arcbitul1 IIIJIIII~nln,lll!dU holltU, hllrl<ll~ I lUI UII•U1•!1TI ~, ..... ..,., .. z 0 V) ~~ "5 ~~ I ~;!! t.J w ~ ..,....._,...,_,._ --~--­...... -t~---1 ..... _III.JIIIa!IDIK.Z.,..... ·~""'" ...... A,..-.....,... ·~--.... . .,.... ...... ~ --SECOND flOOR PlAN --A21 ~ OPEN TO eeLOVi .,____,.,. ... _ ~ ......................... !JiaU'.--~..- ~ !VIIIIRIEIJIII ..... _ .. Ill'~ -- . "' ., .. ... --I IC.OU!o W • 1"0' Ill MAA Arcbitul1 ..,....._,...,_,._ --~--­...... -t~---1 ..... _III.JIIIa!IDIK.Z.,..... ·~""'" ...... A,..-.....,... ·~--.... ..,.... ...... ~ --Tl-IRD flOOR PlAN --A23 _____ , __ ... fWRTH R.00R PIAN A2.4 OPEN TO BEI..O~ • • IIJ ,.. ,.-- Ill MAA Arcbitul1 IIIJIIII~nln,.ll!dU ~~:~~::::,I•T·III::;:;!,.:!~: ..,....._,...,_,._ --~----t~---1 ..... ,.__,....., ·~""'" ...... A,..-.....,... ·~--.... . .,.... ...... ~ --lOOf PIAN --A2.5 A.--....-------... .. o~~~o.....-..-....... ~----- G:J-....... ... [!]...--... -..- [!] ........ ®lt'eH:.., Cl --®___ D .,.,.'IllS-___ _ ®-~·-..... c=J ®=--=--=·---CJ ®~-==!'..-=..-:.~.. C] (!)~-=-~~--c:::::l ®~-==~~,..... ~ ®~-=--Cl (!);::,.'='~==-CJ 0llliCII"~ Cl ®===--=--c::J !l'!t'Jk==:o:.or..=r:r..=n... ·-----··-~~-----. ... =====-=-·------~-----· ... ._.. ..... _ . ...,_. ....... ~--------.....-.... ----i -1[ --=--~-:~._--+i--,-, ...... r -----..,-r--1 -~~.,....1(1 1 1~~~;-n 11 --"'""-i f.----. ----~~-'-"~ I 1-----H--t----------- a ! I I Ill 1 I~ II I II I~ II I I~ ~~j ~ --------·----~=~~===:!r~~~JC~=l·:::::t::t _____ ------ · ... ..! ri I Ill -· 11 ; I i --~~---~~---~ r= '~H ~H lh I:;;~ I I -==--I I -=::.-I I -=::.-I ... ., .. , JJL•uLlL JJ ~iXUH~wuBU¥~u~UON~~---------------------------------------------~-~ .. I ·-------------------------~ ID ----------------.... $1CiN..i':'llr•tl.fl' .~~ ~ ·-~~ --~~=~ \!=~==~~=;:r:=-:;K=p..-===_= __ =_~==---~--~~~ •---..-~---.ffilllfll 1111111 I I I Jl I L I I ,_~ .. lU I I I I ~~~~~~~~~=~~l~l~=t==;:t--_ oo-------=t---HIIIIIII lmln II I I I -~--1-I I I B ----I l WM ~r 1m1 ;; : : : ---·~~~~~~~~~~[;;;~~~--~~- 7--~ ~~cr~ yl ~r--__ c I I I ~ U J ~ -r.r-----Cl~-:_;;-~-~~· ----~~f-o~~~~~~-~--~~~-~:~-~-~~·;E·'-~--~~. ]t·b~·~-~~;:l~~LSH~~U~~!lht"t~Hd:ll .. ~~J. 0----~ / I ~-=~~----------------~ ~~--------------------------------___J ~weoc~~BEV-~u~DON~~------------------------------~-~ .. I IGAI-E: ...... tl.{l' Ill MAA Arcbitul1 IIIJIIII~nln,.ll!dU ~~:~~::::,I•T·III::;:;!,.:!~: ..,......_,...,_,._ --~--­........ -t~---1 ..... _III.JIIIaiiDIK.Z.,..... ·~"""" ...... A,..-.....,... ·~--.... . .,.... ...... ~ --BULDINC BfVAOONS --A3.1 A. ............ ___ ltr ___ ....... ._ .... ..._._ __ A.'UP.,1W .. ___. ..... ...... ~ ............. . [!]-...-... - [!] .............. ,_ [!]-- CDl()l SOIB'JUU ®=~·-...... ®--'II&IA·---®:all'llliM~-- <!'.l--~-­®laii'IJ='~-- ®=.o-=c.-===-.:.==-011t..W ...... _ 0111111r~ ®lall&".&r:..- ·-- ~ ~ ~~..,__.... ..... -.:~ ..... --IIIJU!Ie ._.MI!I'TIIIIIIII-. ztfr-----: _!J -----=-=-----~---------·-----------------------til [ t=f - -~ HU tt I ~ I Hll 'H' I II I I I tt I I Ill I l II I I I I II I I I _ _1 I I I I I h I II - • ----~IH~1 tt II Ill I H~1111 I I I II I I I I I II I I I I I I I I I II I ·-·· ---- II I II • IJ-=-.1 ~II tt 1111 I ~II II I I I T I --~ ± ± ± i ± -I-!T -----! ' Te ! I ~~ 11 ~ H ~ J-,i~i' ~' I 171 ' ' :f.:u I ' I I ' ~ I I ~~~~~JJi~~llllt~~~~~~~~~-------------------------------------------------------------------------~~ • ~n,r---1--~;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;~ IKI!Io.....---.~-... -.J..Iml'•UIIEM.E•~-.er .,...__Hum.-. BC.N..e:t8'•,'G" -&UT~-~--~~DON~~---------------------------------------------~~ ~ti11'•1'G" Ill MAA Arcbitul1 IIIJIIII~nln,.ll!dU ~~:~~::::,I•T·III::;:;!,.:!~: ..,......_,...,_,._ --~--­............ -t~---1 ..... _III.JIIIaiiDIK.Z.,..... ·~"""" ...... A,..-.....,... ·~--.... . .,.... ...... ~ --BULDINC BfVAOONS --A3.2 CONDOMINIUMNai11: !HfS IS A MAP OF A COhfXlM/1<J/1JM PRQ..ECT AS DEF'fNEI) IN SECT/00 21!'!i GF ME 0'\-IL COD£ rF rHE 5TMF OF CAiJFORNU. ~ IS FJI..ED PUR!>UANT TO THE SVBO/V!Slor/ MAP ~CI': THE: ~R Of CONOOMIMVM wrs IS 12; n ~ENTIAL I.NTS ANO I COMME!rC/AL WT. PR<:IPE'RTY 80UMJARY EXJS'TWG .JM:xlD rovr::£ nMSlfW ftQOff CUVArlOV EXISIWC SPOT flEVArnl'l PROPOSED FLOW PAm PROPOSED ASPJ.MLT CONCRC.TE PRCIPOSEl) SroRM ORMI PfPt PROP(JS£[) SroRI.I Di?AIN 80X EXJSnNC ~-H£110 U71UTY EXJ<;l1NC WATER tlltE DJS'llff{j2~~ DIJS'IINC S1DRM !NAW PROPOS£D SroRM DRAIN fXJS71NC .SC:IID! lttMii(){£ EX1S!ING FIR£ HJVRA.'.ll EXJSnNC ~IFR'ME~ PROPQSE[) WATER SERLIIT ,t, MEIER PROPOSED SCH£:&:' UIID?AL PROPOS£D IRRIG>I.TICW PROPQSED CAS LINE Pfl!~ntfe:sun"cr D.Rr..SB.AD MUNIGPAI.. WATm O!SrR!Ct STAAI0.4Ril DRA~NG CITY CF CARLSBAD ST.ANDAROOR'A~ ---~ IZZ/;/Z//1 0 .-fo ,,J)J;. ..---1z-' t" --DH-- --<V>-- --<S)-- --e:::m-- --00-- ,. ... C.M.W.D.S.D. r1fE Af>Pf?O\.£D GR..MX/JC Pl.A'<IS III'J.L 8£ 1?:£\otEIIED FOR ~ANC£ ~m WS S1TE: PU.N. CONSTFWCTION CHIWGES IWA /"' BE R!:.QI.lfl?ro BY mE C!rY [NG!NfiR TO CCNfOI?M TO CURRENT ENCIPE~ STANDARDS .t.ND Pt:XJCI'ES, IF SICMF/CANf_ S/ '/'E" AND 8l.R_{')IN() M(){){fiCA TIONS ARC Pf?OPOSFJ). zo· ALLEY ... C/L TENTATIVE MAP FOR CONDOMINIUM PURPOSES THE GRAND MADISON '""" JO" ,. SHBEI' INDEX !>HffT I· 'fm_E SH£E'f; I(£Y MA.P k NOTE<; SHff:T 2; I ST f1..00R Pf.JW SHff:T .1: 2NlJ FLOOR PI.AN SHffT 4: JRO Fl.OOR PLAN SHfET 5; 4111 fLOOR PLAN SHEET 15; SirE PI.AIV SHEET ~ JroOF DRAJNJ.GE II-DMA. EXHIBIT NO~· THIS !S A IDVT,A,l'll£ MAP tF A r:aNDDMJNIUM PRO.ECT AS lJ£F'1i<J@ IN 5£CTIOO 41:25 OF "n£ O'WL c:oDE lJF 'f1£ StA'IE OF CAL/F"ORMA. m£ f'f?O.JECr CCWT~S A MAXIMUM OF 13 AII?SPAC£. UNIT'S. APPROI'BD MADISON STREET GRAND AVENUE rMS fS rH£ APPff(}\£J} 7ENTAT1'1£" MAP/S'IE PlAN FOR PRO.E.Cr NO. __ P£R COMXriON NO. __ OF PUNNtNC COMM!SS1CW Raa..UOON ""-- LEIJALDE$CRJPTI0N CT15-04(A) RP 15-06(A) l.Oi'S fl. 14. 15 AND 16 IN BLOCK 451 OF CAf?L5BAO ro'MIIS'l'F. W Nf£ ClrY II CARlSBAD, COJNrY OF SAN DIEGO. STAlE OF CAJ..JFORMA. ACCORD//1/G ro 'f1£ IWAP mEREOF NO. .5.J5. FII..£D IN mE tFFJCf:. OF mE COON TY R£caN)ER CF SAN DtE:.GG COCWTY, .WA I' ~ 1888. ~ HER£81' CERnFY JNAT !IE A~ rn£ f¥COIK) OI.INEI?S CF "f1.IE PRCJF£RTY Sli()'M>/ CW 7Hf. IDITA71\£ StJOOHfSON lr!AP AND mAT SAIO MAP SJ-10~ Ail. OW? CONI"/GVOOS 0~/P IN MilCH ~ HA'>£ AffY OC£D OR TRUST" /Nmi'E3"T. ~ (Ao{{)ERSTAMJ mAT OUR PRCPERrY IS CONS!XR£0 CONnWOUS Et.£1'.' IF IT IS S£PAJ?ATED 8Y RQI.DS. STRffl"5". Urll.lrY £ASDIE)ITS. OR RAII.RW.D RIG'H75-llF-W.(Y. OIWER: PAJRfCK S.Wn-1. U..C. A CAU1'T)RM.A UM!TEJJ UAB!UTY COMPANY 260SI ClfXA~ SI"Rffr CARLSBAD. CA. 92008 BNG1NEBR OF WORK ~ Ka8 ENGINEERING, INC. aiJ-··-·- mol lfflliCfl Gallo" Ccurt, Sa1"1t 100 SaR m~gc, GA ~211! (~1!1) 211&-55ru Fo~:: (~1!1) 211&-55&.4- /1:4MAL S~S; RCE 48592 OA rE PROJECT INFfJRMA110N Sr1?'a:T AOORESS: 725 GRANO A 1-E'VUf: CARI..S(JAD, CA A5.'.i£3'50R''5 PAR'Cft ~S;; AP/'i. 20-'-XJJ-21 SffE" AQi'r"AG(;· GR~S$ A~Ar;:[.· 0.12 ACRB (H. Ill+ 51') EI<ISNNG 20NE~ IJIJ..AGE R£WEW (\-R) CENERM Pt.IW.· \o!"l..l.Ac;£ (V) MJMB£R OF LOTS; I WT WJWMf.IM LOT :ili:C 7,!i00 ST ~ffiAa:'S.O U.ND U5E Dl!iri?ICT" I -CARl~ Wl.l.AGE" COlTER 8UtUJI/II(; AR£4: 12.211 S.F. 87. !% tor CO'>ER.AGE RDJEIJ/AL QUAN"Ji71ES· 52'!'l C. 't' A\<ERI.OC DAILY TRAFF"tC: ~DENTIAL· II ADt,ll.Hr X 11 I..Nrs-INI ADT COMMERCIA£ (RFIAiL): 40 ADT/HXJO SF -~":a: :n~7 CRass S.F. IDTA£ ADT"-290 ADT S£1'.E"R: CITY CF CARt.SBAD (13 Ef)I.)'S tl220 GAL PER UllllT) (roU) • Rf"SrocrmAL: 220 GPD X II 00 X (1£00 PU? 00} • 2..420 GPO CCIMMEROAL (!?FlAIL): 1 EDU / 1800 • 4,600 SF / 1,800 • 2.~ X 220 GPO • t;!IJ GPO rorAL GPtJ-Z.OB4 CPO ~ID'?; CARt.SBAD MUN/DPAL IWITER DiSrRICI ~TD!'US-t!Gl': R[SIDENnAL.: .25() GPO X r1-2, 7SO GPD cr:;t,fMERG/A£; 0.2.3 CPD/SF" K 4.!100 SF .. 1,058 GPO IDTA£ GPO -4 • .395 GPO • 3;408 {;Pf) / 1,4-«J .. .2.~4 GPM SCHQC(; GARt.S!l'AD IJMF1£D SCHoa DfS"IRtCT GAS .t fl.ECJRIC: SAN DIEOO ~5 .t fl..fCI"RIC COWAN 'I 7R£?H(]fo,E PACIRC BEU ffiH1HONE COMPANY ARE; CARLSBAD FIRE PRarH:710N DfSTRrr;r CON51"/?AIN75 /NroRMANON; NO CONSrRAlN7"S O:!ST Off miS ffiOPU?TY DRAiNAGE DISTRICT: A (/11. W. ~T,I COSTAL :!.ONf:.· NO B£AC!1 G'ooERLA'r. NO fJL/fUJfl'l(; HEJCHT"; ~· MAX PAffl'JNG: Off-51~; 23 SPACZ"S 1 ffAMJK:APPED SPA« NOTE:.: 0\W£1? ro MAX£ .ARRANGOI£N77> 1'.!1"11" mE arr ro COMPt.Y Ill~ ~Al. PA~Nr; ~r:>; \.!"A \8UAfiO!" PA/fK/MJ 11'1-C.Z:V f"rr PROGRAM l<lf./EH£ APR.iCA£££ SHEEI'10F7 SCALE· 1" 20' TENTATIVE MAP FOR CONDOMINIUM PURPOSES THE GRAND MADISON r------------N55\b51'36-"E -19%1'----, ' 13\'-i2"-11-c 10.0-o~<;-e-c -,-"---6-;;;-sz-- ' ' _o " 00VERED PARKIN6 .20 SPAGES " ' ' ' ' ' ' ' ' " ' " ' " ' 4 I II "' "' ---·------ FIRST FLOOR -C.OMHERGIAL 7HI5 15 mE AFPROffl> rfNCAITVE MAP/5170 PLAN FC>? PRO.ECT NO. __ PER CDND/ITOi'/ Nrl __ OF PLAm;:: COOMISSION R£Sf!WnON CT15-04(A) RP 15-06(A) SHEBT20F7 50ALE.1" 20' TENTATIVE MAP FOR CONDOMINIUM PURPOSES THE GRAND MADISON ,------------N55~51'56"E-t34.8>f!----, ,----------, ,------------'-------~ ___ l __ · ____ , ____ ,_ ' ~' ()I ~I "'' 8' 1<1ortf ' .,.,._ fl..Airm< 5TAif<~ -I L -------------__ · -------____ ·_---__ J_J N55~51'55"E 15'1.88' SECOND FLOOR-RESIDENTIAL flf!S IS fifE APPIWLm IE'ITAlli'E MAP/SirE PUN FOf/ PRO.EGr NO. __ PER IXWIJI71011 NO. __ OF PU.~ CGMM/S!!10N fi£SOLUITON PLANNING DIWSION VATf EN(;I!!ffiliNG DI~S/011 DAlE CF15-04(A) RP 15-06(A) SHEET30F7 SCJ\LE01" 20' TENTATIVE MAP FOR CONDOMINIUM PURPOSES THE GRAND MADISON THIRD FLOOR -RESIDENTIAL """OVBD lJ-IIS IS lHE APPfWIFIJ JEIITA~,-MAP;SIJF PLAN FUR PRO.ECC NO __ PER fXJIIDmOO NO __ DF PLANNING C<J.\!MISSJD/1 1/ESDWllO/I !/0, __ CT15-04(A) RP 15-06(A) SHEET40F7 SC'"-E. 1" 20" IBNTATIVE MAP FOR CONDOMINIUM PURPOSES THE GRAND MADISON N55lb51'36"E IS'1.8l' ,--------;-------------------------~~ L ____ _ :: I " " " " " ~- ' I fOURTH flOOR -RESIDENTIAL THIS IS fHE A""'Olffi roNCA~i£ MAf'/SITO I'!.AN fOI? I'RO.!fCT NO. __ PER CONDWON NO. __ OF PLA"':: COMMI5510N f?£50WnON CT15-04(A) RP 15-06(A) SHBET50F7 TENTATIVE MAP FOR CONDOMINIUM PURPOSES THE GRAND MADISON SITE PLAN CT15-04(A) RP 15-06(A) CATCH BASIN RECONSTRUCTION . -~~~ ...... ~ .. IECIIClOOO lnRAIIIIAC::FDITCH/lRANS TO 0-25 •---a~t~Cm~~.-r~~~ lf .... ~m. --oUfHI1C!'MMIINII-cr ..... am•.,_.~--. ----·1'11111. ::=-..:.~--..~ I ·-· U M •• N ' A •.wlr N 4 e:.•t.... .. i ........ SCALE' 1" = 10' TENTATIVE MAP FOR CONDOMINIUM PURPOSES THE GRAND MADISON LEGEND DMA I -ROOF AREAS DF!AINIIJC ro 4711 FLOOR PLANTER DMA 2 -47/f FLOOR AREAS DRAINING IV :JRD FWOR Pi..ANfFR DMA 3-211[) FWOR AREAS IJI?AINING ro 1ST FLOOR PLMml ROOF DRAINAGE & DMA EXHIBIT • ENQ""'RING SOIL"" >Hill Pfl[)\<OE A "INIMU" SLIST~NEDINRLTllATI(I'>JRATECJ"S'jHR. MI<SHAll BESI<NDYUliW TIJP SOLCON~SllNGCJ"50l!SAND, JMI'tANTINGSCil,,O.SHREOOEilHAR!l"'OOMULOH. LEGEND ilMA I -f/QDF AREAS DRAINIIJG m 471f FLOOR PLANID? ilMA 2 -47/f FLOOR AREAS DRAINING IV :JRD FWOR PLANfFR DMA 3-211[) FWOR AREAS DRAINING 7D 1ST FLOOR PLMml 8QW JHR I e "JER NQJE THERMALOESIGN.,ll8EINACOOR<1\N<£ \\OTH~TMENTCONT1<C'-8"P'SI<NDDURING ~NALDE!lGN,THECURIDJTI>PPR0'£0 STIJRI.j WATER "ANAGE.El>JT PLAN \11ll8E AMENOEOTOREFLECTSAME APPROVED THIS IS THE APPROVED IDJTAT!VE "AP/SITE P""" FO" PROJECT NO. __ PER OON~TlON ""--<>' PLAN~~G GOMMISSim REsruJTlm CT15-04(A) RP 15-06(A) SHEET70F7 1947 1947 HV1 453 1FT O/S BLDG 454 1FT O/S BLDG 455 1FT O/S BLDG 456 1FT O/S BLDG 457 1FT O/S BLDG CN 628 tc dw 629 eob1 630 eob2 b 631 eob2 632 eob2 637 fl 639 eoc3 640 eoc3 641 fl 642 fl 643 eoc3 e 644 fl dw 645 fl dw 646 tc dw 647 ac 648 ac 649 ac SET CL 50 50 OB S . OBS. OBS . Obsc u r e d Are a OBS . 49.4 47.8 50.2 52.750.5 52.2 52.1 51.7 51.6 52.2 52.2 51.9 51.7 49.3 49.2 48.4 51.750.5 Conc.Asph.Conc.1-2 PARKING STALL LIFT 3-4 PARKING STALL LIFT UP STAIR 2 TRASH RECYCLE UP STAIR 1 COMMERCIAL RETAIL 24 SPACESCOVERED PARKING LOBBY CCCCCCCC ELEC. PLAZA ELEV.ELEV. ELEV.EQUIP. 5-6 PARKING STALL LIFT 7-8 PARKING STALL LIFT C 6,308 SF PLANTER S-2 OCC.TYPE 111B CONSTRUCTION LINE OF BUILDINGWALL ABOVE PLT SEAT PLANT 20" tall SEATSEAT2.0%2.0% 0.79%2.0% 49.34 FF 50.67 FF 8.00%2.0%1.0%1.0% 1.0 % 51.60 GF 1.32% 2.0% FLOW THROUGH PLANTER 36"X36" CATCH BASIN WITH PEDESTRIAN GRATE49.02 TG46.0 IE OUT 8" HDPE @ 0.8% 12" HDPE @ 1.0% 18" RCP @25'15'LIMITS OF IMPROVEMENTS 0.5%0.5%\p t0;1.5%24'EXISTING 3 - PARALLEL PARKING SPACES REMOVE EXIST. DRIVEWAY AND CONSTRUCT CURB, GUTTER &SIDEWALK5.5'2.0%2.0% GRADE BREAK W EXISTING WATER SERVICE 2.0% S EXISTING SEWER SERVICE I PROPOSED IRRIGATION SERVICE 17.5' 10' LIMITS OF IMPROVEMENTS19.5'9' REMOVE EXIST. DRIVEWAY AND CONSTRUCT CURB, GUTTER & SIDEWALK PROPOSED 4 PARKING SPACES EXIST. 8" VC SEWER PER DWG 118-9EXIST. 12" STEEL WATER PER DWG 146-9FUTURE 36" RCP SD PER DWG 457-4HEXIST. 12" STEEL WATER PERFUTURE 36" RCP SD PER DWG 457-4HEXIST. 10" ACP WATER PER DWG 445 3" SIDEWALK UNDER DRAIN~EXIST. 8" HDPE STORM DRAIN LIMITS OF IMPROVEMENTS 5'2.95% LIMITS OF IMPROVEMENTS 4" HDPE @ 2.0% MIN. CROSS FALL VARIES ~ SEE ARCHITECT'S PLUMBING PLAN FOR STORM DRAIN ROUTING TO UPPER FLOORS TO FLOW THROUGH PLANTERS 1.7 % 1.7% 4' MAX. MAX. MAX. MAX. EXIST. CURB & GUTTER TO REMAIN EXIST. CURB & GUTTER TO REMAIN EXISTING WATER SERVICE EXIST. CURB & GUTTER TO REMAIN REMOVE EXIST. SIDEWALK & RECONSTRUCT1'1' PL PL PL PL N55°57'48"E 140.01' N55°57'26"E 140.03'N34°02'00"W 100.08'N34°01'30"W 100.10'REMOVE EXIST. SIDEWALK & RECONSTRUCT1'1' REPLACE ASPHALT CONCRETE IN-KIND ~ STATUS OF EXISTINGSDG&E TRANSFORMER TO BE DETERMINED 8.0'(TYP.)15'(TYP.)20'(TYP.)8.5'(TYP.) 9.0'8.0'24'(TYP.)9.25'(TYP.) 18.5'(TYP.)2.44%2.47%2.0%0.75%8.0%0.75% 7.64% 2.50% (2.11%) (2.51%) (2.44%) 4.8%1.00%52 .89 FS2.00%2.17% 3.33%2.78%2.0%5.4%5.9%1 STEP 1 STEP (1.82%) 1.78% 1.15% 1.00% 6.97% 2.14%1.85% 4.13% (3.16%)0.50%0.50%0.89%1.96%1.8%4.44% 1.08%0.89%3.03%) TYPE G-1TG 51.53IE IN. 45.4IE OUT 45.1 CONNECT TO FUTURE 36" RCP STORM DRAIN, CONC LUG PER D-63 IE 43.6 ~ 36" RCPIE IN 44.4 ~ 18" RCP LIMITS OF IMPROVEMENTS 4' WIDE PCCDRAIN PERTHIS SHEET4.1%2.6%\pt0;1.5%\pt0;2.0%\pt0;2.0%2.0%\p t0;2.0%\pt0;VARIES 2.0%2.0%2.0%1 STEP RECONSTRUCT CURB AND GUTTER. ADJUST EXIST. CURB INLET TO GRADE. 3' X 4' TREE PLANTER (TYPICAL)FREPLACE ASPHALT CONCRETE IN-KIND EXIST. CATCH BASIN (1.41%)1.00% PROPOSED LOCATIONS OF ELECTRICAL METERS PROPOSED LOCATIONS OF WATER METERS, WATER SUB-METERS AND GAS METERS GRAND AVE.MADISON ST.FDDCV4'X6"TRANS THE TWO EXISTING LANDSCAPE ISLANDS LOCATED WITHIN THE PUBLIC ROW ARE TO REMAIN. ALL PLANT MATERIALS AND FEATURES SUCH AS DECORATIVE BOULDERS ARE TO BE PROTECTED IN PLACE THROUGHOUT THE CONSTRUCTION OF THE PROPOSED PROJECT. TWO (2) SYAGRUS ROMANZOFFIANUM - QUEEN PALM, 16" CALIPER, TREES TO BE REMOVEDTHREE (3) PODOCARPUS GRACILIOR - FERN PINE, SEE TREE LOCATION FOR CALIPER SIZE. TREES TO REMAIN AND BE PROTECTED IN PLACE DURING CONSTRUCTION (14") (14") (18") PROPERTY LINE, TYPICAL PROPERTY LINE, TYPICAL 25'-0"TWO (2) METROSIDEROS EXCELSUS - NEW ZEALAND CHRISTMAS TREES, MULTI TRUNK WITH LARGEST TRUNK BEING 8" CALIPER, TREES TO REMAIN AND BE PROTECTED IN PLACE DURING CONSTRUCTION SEATING BUILT INTO ADJACENT RAISED PLANTER, SEE ARCHITECT'S PLANS ENHANCED PAVING TYPICAL, SEE ARCHITECT'S PLANS LINE OF SITE LIMIT LINE PER CITY OF CARLSBAD'S LANDSCAPE MANUAL 25'-0"THE THREE PROPOSED PLANTERS LOCATED WITHIN THE PUBLIC R.O.W. WILL BE IMPROVED AND MAINTAINED BY THE PROPERTY OWNER. FLOW THROUGH RAISED PLANTER TO FILTER SECOND FLOOR AND ON GRADE SITE RUNOFF REVISIONS DATE 1 2 3 4 SHEET: OF SHEETS4 PROJECT NO. :15-004 ISSUED FOR DATE DRAWN BY: CHECKED BY: JSS SCALE:PER PLAN DATE:04-25-15THE GRAND MADISON 725 GRAND AVENUECARLSBAD, CALIFORNIA SHEET TITLE JSS PROJECT STAMP CITY SUBMITTALPRELIMINARY - 1st 5/1/15 PLOT DATE:CITY SUBMITTALPRELIMINARY - 2nd 6/17/15 CITY SUBMITTALPRELIMINARY - 3nd 7/24/15 CITY SUBMITTALPRELIMINARY - 4th 9/14/15 9/29/15 9/28/152015-07-29_The Grand Madison_SD-DD.vwxL-1 CONCEPTUALLANDSCAPE PLANSITE/FIRST FLOOR north100 5 10 20 40 SCALE: 1"=10'-0"FEET SITE/FIRST FLOOR PLAN PLANTING LEGEND SYMBOL BOTANICAL NAME COMMON NAME QUANTITY SIZE SPACING WUCOLS TREES - Small Scale Accent METROSIDEROS EXCELSIA NEW ZEALAND CHRISTMAS TREE 3 24" BOX STD.M RHUS LANCEA AFRICAN SUMAC 2 15 GAL.L PALM OR PALM LIKE PLANTS PHOENIX ROEBELENII PIGMY DATE PALM 5 15 GAL.M ZAMIA FURPURACEA CARDBOARD PALM 16 10 GAL.M SHRUBS - High Screening BAMBUSA MULTIPLEX 'GOLDEN GODDESS' GOLDEN GODDESS BAMBOO 15 GAL.4' O.C.M SHRUBS - Low Level Accent JASMINUM ANGULARE SOUTH AFRICAN JASMINE 5 GAL.4' O.C M NANDINA DOMESTICA 'HARBOR DWARF' DWARF HEAVENLY BAMBOO 5 GAL.3' O.C.L LANTANA X 'NEW GOLD' NEW GOLD LANTANA 5 GAL.3' O.C.L SHRUBS - Espalier Form MAGNOLIA GRANDIFLORA 'LITTLE GEM' LITTLE GEM MAGNOLIA 15 GAL ESP.6' O.C.M MAGNOLIA GRANDIFLORA 'LITTLE GEM' LITTLE GEM MAGNOLIA 15 GAL ESP.6' O.C.M FLOWERING PERENNIALS AGAPANTHUS 'GOLD STRIKE' GOLD STRIKE AGAPANTHUS 1 GAL.2' O.C.M TRADESCANTIA PALLIDA PURPLE HEART 1 GAL.2' O.C.M BEGONIA RICHMONDENSIS RICHMONDENSIS BEGONIA 1 GAL.2' O.C.M HEMEROCALLIS 'BITSY' DAYLILY 1 GAL.18" O.C.M SUCCULENTS AND CACTI PEDILATHUS MACROCARPUS DESERT PENCIL BUSH 5 GAL.3' O.C.L GRASSES - Large & Small Scale CAREX DIVULSA BERKELEY SEDGE 2" LINERS 18" O.C.M LOMARDIA LONGIFOLIA BREEZE DWARF MAT RUSH 1 GAL.3' O.C.M PENNISETUM SPATHEOLATUM RYE PUFFS 1 GAL.3' O.C.MACORNUS GRAMINEUS 'OGON' YELLOW LEAVED CALAMUS 1 GAL.18" O.C.H VINES BIGNONIA CAPREOLATA 'TANGERINE BEAUTY' CROSS VINE 5 GAL.6' O.C.M THUNBERGIA GREGGORII ORANGE CLOCK VINE 5 GAL.6' O.C.M GROUND COVER - Inorganic 2" - 4" DIAMETER RIVER ROCK COBBLE VL (COLOR TO BE DETERMINED) NOTE:THIS LEGEND DEFINES PLANT SELECTIONS AND QUANTITIES FOR THE ENTIRE PROJECTAND NOT ON A FLOOR BY FLOOR BASIS. LANDSCAPE MAINTENANCE RESPONSIBILITIES1.THE PROPERTY OWNER WILL BE RESPONSIBLE FOR MAINTAINING ALL LANDSCAPED AREAS THAT LIE WITHIN THE LIMITS OF THE SITE’S PROPERTY LINES AND THE 3 TREE WELLS LOCATED WITHIN THE R.O.W. ALONG GRAND AVENUE. THE CITY OF CARLSBAD WILL BE RESPONSIBLE FOR THE MAINTENANCE OFTHE THE TWO EXISTING PLANTERS AND SMALL EXPANSION AREA WITHIN ONE OF THESE PLANTERS THAT ARE LOCATED ALONG MADISON STREET AND GRAND AVENUE. STATEMENT OF UNDERSTANDING AND COMPLIANCE"I AM FAMILIAR WITH THE REQUIREMENTS FOR THE LANDSCAPE AND IRRIGATION PLANS CONTAINED IN THE CITY OF CARLSBAD'S LANDSCAPE MANUAL AND WATER EFFICIENT LANDSCAPE REGULATIONS. I HAVE PREPARED THIS PLAN IN COMPLIANCE WITH THOSE REGULATIONS AND THE LANDSCAPE MANUAL AND AGREE TO COMPLY WITH ALL REQUIREMENTS WHEN SUBMITTING CONSTRUCTION DOCUMENTS. I CERTIFY THAT THE PLAN IMPLEMENTS THOSE REGULATIONS TO PROVIDE EFFICIENT USE OF WATER." BY: DATE: 7/2415PREPARER: JEFFREY S. SMITH, PLA 2994 DAEDALUS DESIGN GROUP2725 JEFFERSON STREET, SUITE 15BCARLSBAD, CALIFORNIA 92008(760) 720-9337 REVISIONS DATE 1 2 3 4 SHEET: OF SHEETS4 PROJECT NO. :15-004 ISSUED FOR DATE DRAWN BY: CHECKED BY: JSS SCALE:PER PLAN DATE:04-25-15THE GRAND MADISON 725 GRAND AVENUECARLSBAD, CALIFORNIA SHEET TITLE JSS PROJECT STAMP CITY SUBMITTALPRELIMINARY - 1st 5/1/15 PLOT DATE:CITY SUBMITTALPRELIMINARY - 2nd 6/17/15 CITY SUBMITTALPRELIMINARY - 3nd 7/24/15 CITY SUBMITTALPRELIMINARY - 4th 9/14/15 9/29/15 9/28/152015-07-29_The Grand Madison_SD-DD.vwxL-2 CONCEPTUALLANDSCAPE PLANSECOND + THIRD FLOORS north100 5 10 20 40 SCALE: 1"=10'-0"FEET PLANTING LEGENDSYMBOLBOTANICAL NAME COMMON NAME QUANTITY SIZE SPACING WUCOLS TREES - Small Scale Accent METROSIDEROS EXCELSIA NEW ZEALAND CHRISTMAS TREE 3 24" BOX STD.M RHUS LANCEA AFRICAN SUMAC 2 15 GAL.L PALM OR PALM LIKE PLANTS PHOENIX ROEBELENII PIGMY DATE PALM 5 15 GAL.M ZAMIA FURPURACEA CARDBOARD PALM 16 10 GAL.M SHRUBS - High Screening BAMBUSA MULTIPLEX 'GOLDEN GODDESS' GOLDEN GODDESS BAMBOO 15 GAL.4' O.C.M SHRUBS - Low Level Accent JASMINUM ANGULARE SOUTH AFRICAN JASMINE 5 GAL.4' O.C M NANDINA DOMESTICA 'HARBOR DWARF' DWARF HEAVENLY BAMBOO 5 GAL.3' O.C.L LANTANA X 'NEW GOLD' NEW GOLD LANTANA 5 GAL.3' O.C.L SHRUBS - Espalier Form MAGNOLIA GRANDIFLORA 'LITTLE GEM' LITTLE GEM MAGNOLIA 15 GAL ESP.6' O.C.M FLOWERING PERENNIALS AGAPANTHUS 'GOLD STRIKE' GOLD STRIKE AGAPANTHUS 1 GAL.2' O.C.M TRADESCANTIA PALLIDA PURPLE HEART 1 GAL.2' O.C.M BEGONIA RICHMONDENSIS RICHMONDENSIS BEGONIA 1 GAL.2' O.C.M HEMEROCALLIS 'BITSY' DAYLILY 1 GAL.18" O.C.M SUCCULENTS AND CACTI PEDILATHUS MACROCARPUS DESERT PENCIL BUSH 5 GAL.3' O.C.L GRASSES - Large & Small Scale CAREX DIVULSA BERKELEY SEDGE 2" LINERS 18" O.C.M LOMARDIA LONGIFOLIA BREEZE DWARF MAT RUSH 1 GAL.3' O.C.M PENNISETUM SPATHEOLATUM RYE PUFFS 1 GAL.3' O.C.MACORNUS GRAMINEUS 'OGON' YELLOW LEAVED CALAMUS 1 GAL.18" O.C.H VINES BIGNONIA CAPREOLATA 'TANGERINE BEAUTY' CROSS VINE 5 GAL.6' O.C.M THUNBERGIA GREGGORII ORANGE CLOCK VINE 5 GAL.6' O.C.M GROUND COVER - Inorganic 2" - 4" DIAMETER RIVER ROCK COBBLE VL (COLOR TO BE DETERMINED) NOTE:THIS LEGEND DEFINES PLANT SELECTIONS AND QUANTITIES FOR THE ENTIRE PROJECTAND NOT ON A FLOOR BY FLOOR BASIS. STAIR 2 DN STAIR 1 ELEV.ELEV. DN UP COMMON AREA STAIR 2 UP OFFICE4,064 S.F. NET PLANTER PLANTER WALKWAY WOMEN MEN POTENTIAL FUTURE DEMISING WALL POTENTIALFUTUREDEMISINGWALL DECK 5,080 S.F. GROSS DECK DECK SEATSEAT SEAT916 S.F.130 S.F. 105 S.F. UNUSEDAREA FLOW THROUGH RAISED PLANTERS TO FILER STORMWATER RUNOFF FROM THIRD FLOOR FLOW THROUGH RAISED PLANTERS TO FILTER STORMWATER RUNOFF FROM THIRD FLOOR SECOND FLOOR DN STAIR 1 ELEV.ELEV. UP DN PLANTERPLANTER OPEN TO BELOW STAIR 2 UP WALKWAY DECK PLANTER BELOW STAIRROOFBELOW POTENTIAL FUTURE DEMISING WALL POTENTIALFUTUREDEMISINGWALL DECKDECK DECK DECK OPENTOBELOW 130 S.F. 126 S.F. 126 S.F. 128 S.F. 105 S.F. OFFICE4,064 S.F. NET5,080 S.F. GROSS FLOW THROUGH RAISED PLANTERS TO FILTER STORMWATER RUNOFF FROM ROOF LEVEL THIRD FLOOR REVISIONS DATE 1 2 3 4 SHEET: OF SHEETS4 PROJECT NO. :15-004 ISSUED FOR DATE DRAWN BY: CHECKED BY: JSS SCALE:PER PLAN DATE:04-25-15THE GRAND MADISON 725 GRAND AVENUECARLSBAD, CALIFORNIA SHEET TITLE JSS PROJECT STAMP CITY SUBMITTALPRELIMINARY - 1st 5/1/15 PLOT DATE:CITY SUBMITTALPRELIMINARY - 2nd 6/17/15 CITY SUBMITTALPRELIMINARY - 3nd 7/24/15 CITY SUBMITTALPRELIMINARY - 4th 9/14/15 9/29/15 9/28/152015-07-29_The Grand Madison_SD-DD.vwxL-3 CONCEPTUALLANDSCAPE PLANFOURTH FLOOR north100 5 10 20 40 SCALE: 1"=10'-0"FEET PLANTING LEGENDSYMBOLBOTANICAL NAME COMMON NAME QUANTITY SIZE SPACING WUCOLS TREES - Small Scale Accent METROSIDEROS EXCELSIA NEW ZEALAND CHRISTMAS TREE 3 24" BOX STD.M RHUS LANCEA AFRICAN SUMAC 2 15 GAL.L PALM OR PALM LIKE PLANTS PHOENIX ROEBELENII PIGMY DATE PALM 5 15 GAL.M ZAMIA FURPURACEA CARDBOARD PALM 16 10 GAL.M SHRUBS - High Screening BAMBUSA MULTIPLEX 'GOLDEN GODDESS' GOLDEN GODDESS BAMBOO 15 GAL.4' O.C.M SHRUBS - Low Level Accent JASMINUM ANGULARE SOUTH AFRICAN JASMINE 5 GAL.4' O.C M NANDINA DOMESTICA 'HARBOR DWARF' DWARF HEAVENLY BAMBOO 5 GAL.3' O.C.L LANTANA X 'NEW GOLD' NEW GOLD LANTANA 5 GAL.3' O.C.L SHRUBS - Espalier Form MAGNOLIA GRANDIFLORA 'LITTLE GEM' LITTLE GEM MAGNOLIA 15 GAL ESP.6' O.C.M FLOWERING PERENNIALS AGAPANTHUS 'GOLD STRIKE' GOLD STRIKE AGAPANTHUS 1 GAL.2' O.C.M TRADESCANTIA PALLIDA PURPLE HEART 1 GAL.2' O.C.M BEGONIA RICHMONDENSIS RICHMONDENSIS BEGONIA 1 GAL.2' O.C.M HEMEROCALLIS 'BITSY' DAYLILY 1 GAL.18" O.C.M SUCCULENTS AND CACTI PEDILATHUS MACROCARPUS DESERT PENCIL BUSH 5 GAL.3' O.C.L GRASSES - Large & Small Scale CAREX DIVULSA BERKELEY SEDGE 2" LINERS 18" O.C.M LOMARDIA LONGIFOLIA BREEZE DWARF MAT RUSH 1 GAL.3' O.C.M PENNISETUM SPATHEOLATUM RYE PUFFS 1 GAL.3' O.C.MACORNUS GRAMINEUS 'OGON' YELLOW LEAVED CALAMUS 1 GAL.18" O.C.H VINES BIGNONIA CAPREOLATA 'TANGERINE BEAUTY' CROSS VINE 5 GAL.6' O.C.M THUNBERGIA GREGGORII ORANGE CLOCK VINE 5 GAL.6' O.C.M GROUND COVER - Inorganic 2" - 4" DIAMETER RIVER ROCK COBBLE VL (COLOR TO BE DETERMINED) NOTE:THIS LEGEND DEFINES PLANT SELECTIONS AND QUANTITIES FOR THE ENTIRE PROJECTAND NOT ON A FLOOR BY FLOOR BASIS. DN STAIR 1 ELEV. UP CONDO UNIT A PLANTERSTAIR 2 2 BEDROOM OPEN TO BELOW PLANTER CONDO UNIT B UP CONDO UNIT DCONDO UNIT C DN WALKWAYW/D BATH 2 CL F KITCHEN DINING LIVING BEDRM 2 BEDRM 1 BATH 1 W/D F CL CL CL W/D F 1,425 S.F. 2 BEDROOM 1,258 S.F.1,446 S.F.2 BEDROOM 2 BEDROOM1,464 S.F.W/D F BEDRM 2 BEDRM 2BEDRM 1 BEDRM 2 BEDRM 1 BEDRM 1 BATH 1 CL CL CL CL CLCL CL KITCHEN KITCHEN KITCHEN LIVING LIVING LIVINGDININGDININGDINING BATH 1 BATH 1 BATH 2 BATH 2 BATH 2 PLANTER BELOW STAIRROOFBELOW DECK STORAGE STORAGE STORAGE STORAGE 217 S.F. DECK DECK DECKDECK Art. 383 Art. 383 130 S.F.126 S.F.126 S.F.128 S.F. 105 S.F. OPENTOBELOW FLOW THROUGH RAISED PLANTERS TO FILTER STORMWATER RUNOFF FROM ROOF LEVEL FOURTH FLOOR REVISIONS DATE 1 2 3 4 SHEET: OF SHEETS4 PROJECT NO. :15-004 ISSUED FOR DATE DRAWN BY: CHECKED BY: JSS SCALE:PER PLAN DATE:04-25-15THE GRAND MADISON 725 GRAND AVENUECARLSBAD, CALIFORNIA SHEET TITLE JSS PROJECT STAMP CITY SUBMITTALPRELIMINARY - 1st 5/1/15 PLOT DATE:CITY SUBMITTALPRELIMINARY - 2nd 6/17/15 CITY SUBMITTALPRELIMINARY - 3nd 7/24/15 CITY SUBMITTALPRELIMINARY - 4th 9/14/15 9/29/15 9/28/152015-07-29_The Grand Madison_SD-DD.vwxL-4 CONCEPTUALWATERCONSERVATION PLAN SCALE: 1" = 20'-0"FEET 20 0 10 20 40 80 north MAXIMUM APPLIED WATER ALLOWANCE (MAWA) CALCULATION:MAWA =MAXIMUM APPLIED WATER ALLOWANCE (GALLONS PER YEAR)ETO =REFERENCE EVAPOTRANSPIRATION (INCHES PER YEAR)0.7 =ET ADJUSTMENT FACTOR (ETAF)LA =LANDSCAPED AREA INCLUDES SPECIAL LANDSCAPE AREA (SQ. FT.)0.62=CONVERSION FACTOR (TO GALLONS PER SQUARE FOOT)SLA=PORTION OF THE LANDSCAPE AREA IDENTIFIED AS SPECIAL LANDSCAPE AREA (SQ. FT.)0.3 =THE ADDITIONAL ET ADJUSTMENT FACTOR FOR SPECIAL LANDSCAPE AREA (1.0 – 0.7 = 0.3)MAWA = (ETO) (0.62) [(0.7 x LA) + (0.3 x SLA)]= (42.9) (0.62) X [(0.7 X 2,222)]= (26.6)x(1,555) MAXIMUM APPLIED WATER ALLOWANCE = 41,363 GALLONS PER YEAR ESTIMATED TOTAL WATER USE (ETWU) CALCULATION: ETWU =ESTIMATED TOTAL WATER USE PER YEAR (GALLONS PER YEAR)ETO = REFERENCE EVAPOTRANSPIRATION (INCHES PER YEAR)PF = PLANT FACTOR FROM WUCOLSHA = HYDROZONE AREA [HIGH, MEDIUM, AND LOW WATER USE AREAS] (SQ. FT.)SLA = SPECIAL LANDSCAPE AREA (SQ. FT.)0.62 = CONVERSION FACTOR (TO GALLONS PER SQUARE FOOT)IE =IRRIGATION EFFICIENCY (MINIMUM 0.71) ETWU = (ETO) (0.62) [(PF x HA) / IE) + SLA] ETWU FOR HWU ZONE = (42.9) (0.62) [(.80 X 46) / .90] = 26.6 X [37/ .90] = 26.6 X 41 = 1,090 GPY ETWU FOR MWU ZONE = (42.9) (0.62) [(.50 X 1,761) / .90] = 26.6 X [880 /.90] = 26.6 X 978 = 26,015 GPY ETWU FOR LWU ZONE = (42.9) (0.62) [(.30 X 280) / .90] = 26.6 X [124 / .90] = 26.6 X 138 = 3,680 GPY ESTIMATED TOTAL WATER USE = 30,785 GALLONS PER YEAR WATER USE SUMMARY:THE TOTAL ETWU FOR ALL HYDROZONES IS 10,578 GALLONS LESS THAN THE MAWA, SO THE PROPOSED LANDSCAPE AND IRRIGATION DESIGN FOR THIS PROJECT SATISFIES THE STATE MODEL WATER EFFICIENT LANDSCAPE ORDINANCE. HIGH WATER USE !46 S.F. !.80 PLANT FACTOR (PF) MEDIUM WATER USE !1,761 S.F. !.50 PLANT FACTOR (PF) LOW WATER USE !415 S.F. !.30 PLANT FACTOR (PF) VERY LOW WATER USE !0 S.F. !.10 PLANT FACTOR (PF) SYMBOL DESCRIPTION WATER USE HYDROZONE DATA HWU MWU LWU VLWU NOTE:ALL ON GRADE AND RAISED PLANTER BEDS WILL BE IRRIGATED WITH A SUBSURFACE DRIP IRRIGATION SYSTEM STAIR 2 DN STAIR 1 ELEV.ELEV. DN UP COMMON AREA STAIR 2 UP OFFICE4,064 S.F. NET PLANTER PLANTER WALKWAY WOMEN MEN POTENTIAL FUTURE DEMISING WALL POTENTIALFUTUREDEMISINGWALL DECK5,080 S.F. GROSS DECK DECK SEATSEAT SEAT916 S.F.130 S.F. 105 S.F. UNUSEDAREA MWUMWUMWU LWU LWU LWU LWU SECOND FLOOR DN STAIR 1 ELEV.ELEV. UP DN PLANTERPLANTER OPEN TO BELOW STAIR 2 UP WALKWAY DECK PLANTER BELOW STAIRROOFBELOW POTENTIAL FUTURE DEMISING WALL POTENTIALFUTUREDEMISINGWALL DECKDECK DECK DECK OPENTOBELOW 130 S.F. 126 S.F. 126 S.F. 128 S.F. 105 S.F. OFFICE4,064 S.F. NET5,080 S.F. GROSS MWUMWUMWU MWU MWU THIRD FLOOR DN STAIR 1 ELEV. UP CONDO UNIT A PLANTER STAIR 2 2 BEDROOM OPEN TO BELOW PLANTER CONDO UNIT B UP CONDO UNIT D CONDO UNIT C DN WALKWAYW/D BATH 2 CL F KITCHEN DINING LIVING BEDRM 2 BEDRM 1 BATH 1 W/D F CL CL CL W/D F 1,425 S.F. 2 BEDROOM 1,258 S.F. 1,446 S.F. 2 BEDROOM 2 BEDROOM1,464 S.F. W/D F BEDRM 2 BEDRM 2BEDRM 1 BEDRM 2 BEDRM 1 BEDRM 1 BATH 1 CL CL CL CL CLCL CL KITCHEN KITCHEN KITCHEN LIVING LIVING LIVING DINING DINING DINING BATH 1 BATH 1 BATH 2 BATH 2 BATH 2 PLANTER BELOW STAIRROOFBELOW DECK STORAGE STORAGE STORAGE STORAGE 217 S.F. DECK DECK DECK DECK Art. 383 Art. 383 130 S.F. 126 S.F. 126 S.F. 128 S.F. 105 S.F. OPENTOBELOW MWU MWU MWU FOURTH FLOOR WATER CONSERVATION PRINCIPALS TO BE IMPLEMENTED WITHIN THIS PROJECT 1.GOOD PLANTING DESIGN BASED ON THE SELECTION OF A BALANCED PALLET OF LOW AND MEDIUM WATER CONSUMING PLANTS AND MINIMAL USE OF HIGH WATER CONSUMING PLANT SPECIES. ARRANGMENT OF THESE PLANTS INTO LIKE WATER USE ZONES. 2.THOROUGH SOIL PREPARATION BY INCORPORATING PROCESSED ORGANICS NTO THE EXISTING SITE SOIL. THIS WILL INCREASE THE SOIL'S WATER HOLDING CAPACITIES AND ALSO ENCOURAGE HIGHER LEVELS OFMICROBIC ACTIVITY IN THE SOIL. HIGHER LEVELS OF MICROBIC ACTIVITY PROMOTE GOOD PLANT HEALTH AND GROWTH THUS LIMITING THE USE OF CHEMICAL FERTILIZERS. 3.LIMIT THE USE OF ORNAMENTAL TURF AREAS. NO ORNAMENTAL TURF WILL BE A PART OF THIS PROJECT. 4.SELECTION OF LOW WATER DEMAND PLANTS (PLEASE REVIEW PLANT LEGEND). 5.INCORPORATION OF EFFECTIVE AND EFFICIENT IRRIGATION DESIGN CONCEPTS, I.E. CIRCUIT ZONES BASED UPON SUN / SHADE EXPOSURE AND SLOPE VS LEVEL PLANTING AREAS, GROUP TREES, SHRUBS, AND GROUND COVERS SEPARATELY FROM LAWNS, USE OF SUBSURFACE DRIP AND MICROSPRAY IRRIGATION WATER DELIVERY HARDWARE, SPECIFICATION OF WEATHER BASED IRRIGATION CONTROLLER WITH THE ABILITY TO MANAGE MULTIPLE PROGRAMS, INCORPORATE ANTI DRAIN CHECK VALVES TO ELIMINATE LOW HEAD DRAINAGE AND USE OF A FLOW SENSOR/MASTER VALVE CONFIGURATION PROGRAMMED TO DETECT LINE AND SPRINKLER BREAKS AND TO SHUT THE SYSTEM DOWN WHEN BREAK ARE DETECTED. 6.INCORPORATION OF SHREDDED WOOD MULCH APPLIED TO THE SURFACE OF ALL SHRUB AND GROUND COVER AREAS IN ORDER TO REDUCE SOIL MOISTURE EVAPORATION AND TO IMPROVE SOIL STRUCTURE BY THE DECOMPOSITION OF THE ORGANIC MULCH OVER TIME. 7.PROPER LANDSCAPE MAINTENANCE AND MANAGEMENT. THIS WILL BE ACCOMPLISHED BY HIRING A PROVEN LANDSCAPE MAINTENANCE CONTRACTOR KNOWLEGABLE IN THE PRACTICE OF GOOD XERISCAPE PRINCIPALS. THIS CONTRACTOR WILL PROVIDE AN ONGOING EVALUATION AND ADJUSTMENT PROGRAM TO INSURE THEABOVE MENTIONED PRINCIPALS ARE WORKING TO THEIR UTMOST EFFICIENCY OVER THE LIFE OF THIS LANDSCAPE. ACCOMMODATIONS FOR RECLAIMED WATER 1.ALL PLANTED AREAS REPRESENTED IN A HATCH PATTERN ON THIS SHEET ARE TO BE IRRIGATED WITH POTABLE WATER AT THIS TIME, HOWEVER THE NEW IRRIGATION SYSTEM WILL BE DESIGNED TO ACCOMMODATE THE USE OF RECLAIMED WATER IN THE FUTURE SHOULD IT BECOME AVAILABLE. LANDSCAPE MAINTENANCE RESPONSIBILITIES 1.THE PROPERTY OWNER WILL BE RESPONSIBLE FOR MAINTAINING ALL LANDSCAPED AREAS THAT LIE WITHIN THE LIMITS OF THE SITE’S PROPERTY LINES AND THE 3 TREE WELLS LOCATED WITHIN THE R.O.W. ALONG GRAND AVENUE. THE CITY OF CARLSBAD WILL BE RESPONSIBLE FOR THE MAINTENANCE OFTHE THE TWO EXISTING PLANTERS AND SMALL EXPANSION AREA WITHIN ONE OF THESE PLANTERS THAT ARE LOCATED ALONG MADISON STREET AND GRAND AVENUE. 355 462CK TO 1947463CK TO 19471947FD PK HV1 4531FT O/S BLDG4541FT O/S BLDG4551FT O/S BLDG 4561FT O/S BLDG 4571FT O/S BLDG 459FD CN 645fl dw646tc dw 647ac 648 ac 649ac 81SET CL 50 50 OBS.OBS. Obscu r e d Area 49.4 50.2 52.750.5 52.2 51.7 51.6 52.2 52.2 49.3 49.2 48.4 51.7 Conc.Asph.Asph.1-2PARKING STALL LIFT 3-4 PARKING STALL LIFT UP STAIR 2 TRASH RECYCLEUP STAIR 1 COMMERCIAL RETAIL 24 SPACESCOVERED PARKING LOBBY 9 C10C11C12C13C14C15C16C 22212018 ELEC. PLAZA ELEV.ELEV.ELEV.EQUIP. 5-6 PARKING STALL LIFT 7-8 PARKING STALL LIFT 17C 19 23 24 6,308 SF PLANTER S-2 OCC.TYPE 111B CONSTRUCTION LINE OF BUILDINGWALL ABOVE PLT SEAT PLANT 20" tallSEATSEAT 2.0%2.0% 0.79%2.0% 49.34 FF 50.67 FF 8.00%2.0%1.0%1.0% 1.0% 51.60 GF 1.32% 2.0% FLOW THROUGH PLANTER 36"X36" CATCH BASIN WITH PEDESTRIAN GRATE49.02 TG46.0 IE OUT 8" HDPE @ 0.8% 12" HDPE @ 1.0%25'15'LIMITS OF IMPROVEMENTS 0.5%0.5%\pt0;1.5%24'EXISTING 3 - PARALLEL PARKING SPACES REMOVE EXIST. DRIVEWAY AND CONSTRUCT CURB, GUTTER &SIDEWALK5.5'2.0%2.0%GRADE BREAK W EXISTING WATER SERVICE2.0% S EXISTING SEWER SERVICE I PROPOSED IRRIGATION SERVICE 17.5' 10' LIMITS OF IMPROVEMENTS19.5'9' REMOVE EXIST. DRIVEWAY AND CONSTRUCT CURB, GUTTER & SIDEWALK PROPOSED 4 PARKING SPACES EXIST. 12" ST EEL W ATER PER DWG 146 -9 FUTURE 36" RCP SD PER DWG 457-4HEXIST. 12" STEEL WATER PEREXIST. 10" VC SEWER PER DWG 118-9 3" SIDEWALK UNDER DRAIN~EXIST. 8" HDPE STORM DRAIN LIMITS OF IMPROVEMENTS 5'2.95% 4" HDPE @ 2.0% MIN. CROSS FALL VARIES~ SEE ARCHITECT'S PLUMBING PLAN FOR STORM DRAIN ROUTING TO UPPER FLOORS TO FLOW THROUGH PLANTERS 1.7% 1.7% 4' MAX. MAX. MAX. MAX. EXIST. CURB & GUTTER TO REMAIN EXIST. CURB & GUTTER TO REMAIN EXISTING WATER SERVICE EXIST. CURB & GUTTER TO REMAINREMOVE EXIST. SIDEWALK & RECONSTRUCT1'1'PL PL PL PL N55°57'48"E 140.01' N55°57'26"E 140.03'N34°02 '0 0"W 10 0. 08 'N34°0 1 '30 "W 100.10 'REMOVE EX IST . SID EW ALK & RECONSTRUCT 1' 1' ~ STATUS OF EXISTINGSDG&E TRANSFORMER TO BE DETERMINED 8.0'(TYP.) 15' (TYP. )20'(TYP .) 8.5'(TYP.)9.0'8.0'24' (TYP . )9.25' (TY P. ) 18.5'(TYP.) 2.44%2.0%0.75% 8.0%0.75% 7.64% 4.8%1.00%52.89 FS 2.00% 2.17% 3.33%2.78%2.0%5.4%5.9%1 STEP 1 STEP 1.78% 1.15% 1.00% 6.97% 2.14%0.50%0.50%1.96%4.44% 1.08%4.1%2.6%\pt0;1.5%\pt0;2.0%\pt0;2.0%2.0%\pt0;2.0%\pt0;VARIES2.0%2.0%2.0% 1 STEP RECONSTRUCT CURB AND GUTTER. ADJUST EXIST. CURB INLET TO GRADE.3' X 4' TREE PLANTER (TYPICAL)FREPLACE ASPHALT CONCRETE IN-KIND EXIST. CATCH BASIN (1.41%)1.00% PROPOSED LOCATIONS OF ELECTRICAL METERS PROPOSED LOCATIONS OF WATER METERS, WATER SUB-METERS AND GAS METERS GRAND AVE.MADISON ST.FDDCV4'X6"TRANS MWU MWU MWU MWU HWU MWU MWU MWU MWU MWU MWU SITE / FIRST FLOOR PLAN