Loading...
HomeMy WebLinkAbout2017-09-06; Planning Commission; ; CDP 2017-0016 (DEV2017-0050) – ALLEN ADDITION The City of CARLSBAD Planning Division A REPORT TO THE PLANNING COMMISSION Single Family Coastal Development Permit Item No. Application complete date: July 6, 2017 P.C. AGENDA OF: September 6, 2017 Project Planner: Paul Dan Project Engineer: Tecla Levy SUBJECT: CDP 2017-0016 (DEV2017-0050) – ALLEN ADDITION – Request for approval of a Coastal Development Permit to allow for the addition of 660 square feet of habitable space to an existing single-family residence within the Mello II Segment of the City’s Local Coastal Program located at 4809 Refugio Avenue within Local Facilities Management Zone 1. The project site is not within the appealable area of the California Coastal Commission. The City Planner has determined that the project belongs to a class of projects that the State Secretary for Resources has found do not have a significant impact on the environment, and it is therefore categorically exempt from the requirement for the preparation of environmental documents pursuant to Section 15301(e)(1) interior and exterior alterations and additions to an existing structure of the state CEQA Guidelines. I. RECOMMENDATION That the Planning Commission ADOPT Planning Commission Resolution No. 7264 APPROVING Coastal Development Permit CDP 2017-0016 based upon the findings and subject to the conditions contained therein. II. PROJECT DESCRIPTION AND BACKGROUND Project Site/Setting: The 0.19 acre (8,276 square feet) project site is located at 4809 Refugio Avenue as shown on the attached location map. The lot is developed with a single-family residence and associated hardscape and landscape improvements, and the topography on-site is relatively flat. The neighborhood is characterized by one- and two-story single-family residences, with two-car garages. The project would not require grading or the removal of native vegetation. No natural topographic features exist on the site. Table “A” below includes the General Plan designations, zoning and current land uses of the project site and surrounding properties. TABLE A Location General Plan Designation Zoning Current Land Use Site R-4 R-1-8000 Single-family residence North R-4 R-1-8000 Single-family residence South R-4 R-1-8000 Single-family residence East R-4 R-1-8000 Single-family residence West R-4 R-1-8000 Single-family residence Proposed Residential Construction: The project consists of an addition of 660 square feet of new habitable space to the existing 1,618 square foot residence and an expansion of the existing garage. The majority of the additions are located to the rear of the house and include expansion of the family room, a new bedroom and bathroom, and 68 square feet added to the garage. The additions are proposed to match the style and materials of the existing residence. The residence would remain one-story with no increase in height. 2 CDP 2017-0016 (DEV2017-0050) – ALLEN ADDITION September 6, 2017 Page 2 Proposed Grading: Estimated grading quantities include 0 cubic yards (cy) of cut and 0 cy of fill. A grading permit will not be required for this project. III. ANALYSIS The project is subject to the following regulations and requirements: A. R-4 Residential General Plan Land Use Designation; B. One-Family Residential (R-1) Zone (CMC Section 21.10); C. Coastal Development Regulations for the Mello II Segment of the Local Coastal Program (CMC Section 21.201) and the Coastal Resource Protection Overlay Zone (CMC Section 21.203); D. McClellan-Palomar Airport Land Use Compatibility Plan (ALUCP) – Airport Overflight Notification Area; E. Inclusionary Housing Ordinance (CMC Chapter 21.85); and F. Growth Management (CMC Chapter 21.90). The recommendation for approval of this project was developed by analyzing the project’s consistency with the applicable city regulations and policies. The project’s compliance with each of the above regulations is discussed in detail in the sections below. A. General Plan Land Use Designation The project site has a General Plan Land Use designation of R-4, which allows the development of one- family dwellings at a density of 0-4 dwelling units per acre with a Growth Management Control Point (GMCP) of 3.2 dwelling units per acre. The project has a net acreage of 0.19 and a density of 4.2 dwelling units per acre, which is above the GMCP and the range of the R-4 General Plan Land Use designation. However, one single-family residence is permitted to be constructed on a legal lot that existed as of October 28, 2004, pursuant to General Plan Residential Land Use Policy 2-P.7. Since a single-family dwelling already exists on the property, and the subject lot was legally created prior to October 28, 2004, by map no. 8177, the project is consistent with the R-4 General Plan Land Use designation. B. R-1 Residential Zone (CMC Section 21.10) The project is required to comply with all applicable regulations and development standards of the Carlsbad Municipal Code (CMC) including the One-Family Residential (R-1) zone. The proposed project meets or exceeds all applicable requirements of the R-1 zone (Shown in Table B below). TABLE B – R-1-8,000 ZONE DEVELOPMENT STANDARDS STANDARD REQUIRED/ALLOWED PROPOSED Front Yard Setback 20’ 22’ Side Yard Setback 7’-1” 7’-8” Rear Yard Setback 15’ 24’ Max Building Height 30’ with > 3:12 roof pitch 14’-10” Lot Coverage 40% maximum 34% Parking Two-car garage (20’X20’) Two-car garage CDP 2017-0016 (DEV2017-0050) – ALLEN ADDITION September 6, 2017 Page 3 C. Conformance with the Coastal Development Regulations for the Mello II Segment of the Local Coastal Program (CMC Chapter 21.201) and the Coastal Resource Overlay Zone (CMC Chapter 21. 203) The project site is located within the Mello II Segment of the Local Coastal Program and is not within the appeals jurisdiction. The site is also located within and subject to the Coastal Protection Resource Overlay Zone. The project’s compliance with each of these programs and ordinances is discussed below: 1. Mello II Segment of the Certified Local Coastal Program and all applicable policies The subject site has a Local Coastal Program (LCP) Land Use Plan designation of R-4 Residential, which allows for a density of 0 to 4 du/acre and 3.2 du/acre at the Growth Management Control Point (GMCP). At the R-4 GMCP, 0.6 dwelling units would be permitted on this 0.19 acre (net developable) property. However, one single-family residence is permitted to be constructed on a legal lot that existed as of October 28, 2004, pursuant to General Plan Residential Land Use Policy 2-P.7. The subject lot was legally created prior to October 28, 2004; therefore, the existing single-family residence and proposed additions are consistent with the R-4 LCP Land Use Plan designation. The project consists of additions to an existing single-family residence that include 660 square feet of habitable space and a 68 square foot garage addition in an area designated for residential development. The additions to the existing single-story residence will not obstruct views of the coastline as seen from public lands or the public right-of-way, or otherwise damage the visual beauty of the coastal zone. No agricultural uses currently exist on the previously developed site, nor are there any sensitive resources located on the developable portion of the site. The proposed additions are not located in an area of known geologic instability or flood hazard. Since the site does not have frontage along the coastline, no public opportunities for coastal shoreline access are available from the subject site. Furthermore, the residentially designated site is not suited for water-oriented recreation activities. 2. Coastal Resource Protection Overlay Zone The project is consistent with the provisions of the Coastal Resource Protection Overlay Zone (CMC Chapter 21.203 of the Zoning Ordinance) in that the project will adhere to the City’s Master Drainage Plan, Grading Ordinance, Storm Water Ordinance, BMP Design Manual and Jurisdictional Runoff Management Program (JRMP) to avoid increased urban run-off, pollutants and soil erosion. The subject property does not include steep slopes (equal to or greater than 25 percent gradient) or native vegetation. D. McClellan-Palomar Airport Land Use Compatibility Plan (ALUCP) – Airport Overflight Notification Area The project site is located within the McClellan-Palomar Airport Land Use Compatibility Plan (ALUCP), more specifically the Airport Overflight Notification Area. ALUCP Section 2.2.29 – Overflight Notification is designed to ensure that prospective buyers near an airport, particularly residential properties, are informed about the airport’s potential impact on the property. This notification does not restrict the height of structures, it simply discloses the existing conditions that may affect the property. ALUC Section 3.6.3 requires an overflight notification to be recorded on residential development. Since a notice has not been previously recorded, the applicant is conditioned to do so. CDP 2017-0016 (DEV2017-0050) – ALLEN ADDITION September 6, 2017 Page 4 E. Inclusionary Housing Ordinance (CMC Chapter 21.85) Pursuant to CMC Chapter 21.85.030.D.1, a project may be exempt from the inclusionary housing requirement if an existing residence is altered, improved, restored, repaired, expanded, or extended, provided that the number of units is not increased. Since there will not be an increase in the number of units on the property, the project is exempt from the inclusionary housing requirement. F. Growth Management The proposed project is located within Local Facilities Management Zone 1 in the Northwest Quadrant of the city. No impacts are associated with the project as the project consists of a remodel and additions to an existing residence and no new impacts will be generated. IV. ENVIRONMENTAL REVIEW This project is exempt from CEQA per the exemptions listed below: (1) Section 15301(e)(1) of CEQA exemptions (Class 3) exempts additions to existing structures that will not result in an increase of more than 50 percent of the floor area of the structure before the addition. A Notice of Exemption will be filed by the City Planner upon project approval. ATTACHMENTS: 1. Planning Commission Resolution No. 7264 2. Location Map 3. Disclosure Form 4. Reduced Exhibits 5. Exhibit(s) “A” – “I”, dated September 6, 2017 HILLSIDE DRREFUGIO AVNEBLINA DRSEVILLA WYVALENCIA AVCDP 2017-0016Allen Additions SITE MAP SITE EL CAMINO R E A LLA COSTA AV A L G A R D C A R L S B A D B L . .'..:~----------- (cityof Carlsbad · DISCLOSURE STATEMENT P-1(A) Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov Applicant's statement or disclosure of certain ownership interests on all applications which will require discretionary action on the part of the City Council or any appointed Board, Commission · or Committee. The following information MUST be disclosed at the time of application submittal. Your project cannot be reviewed until this information is completed. Please print. Note: Persbn is defined as "Any individual, firm, co-partnership, joint venture, association, social club, fraternal organization, corpon3tion, estate, trust, receiver, syndicate, in this and any other county1 city and county, city municipality, district or other political subdivision or any other group orqombination acting as a unit." Agents may sign this document; however, the legal name and entity of the applicant and property owner must b~ proyid~d bel9w~ 1. APPLICANT (Not the applicant's agent) Provide the COMPLETE, LEGAL names and addresses of ALL persons having a financial interest in the application. If the applicant includes a corporation or partnership. include the names, titles, addresses of all individuals owning more than 10% of the shares. IF NO INDIVIDUALS OWN MORE THAN 10% OF THE SHARES, PLEASE INDICATE NON-APPLICABLE (N/A) IN THE SPACE BELOW. If a publicly-owned corporation, include the names, titles, and addresses of the corporate officers. (A separate page may be-attached if necessary.) PersonJ@vfs t \Xlrn'e.l k A-He!Vl Corp/Part _________ _ Title___________ Title ____________ _ Address 4~69 }2.e~uJ~t) Aven.\.LQ..) Address __________ _ Cb(lS\..xi.df (_Ft 2. OWNER (Not the owner's agent) 9 "-~~ P-1 (A) Provide the COMPLETE, LEGAL names and addresses of ALL persons having any ownership interest in the property involved. Also, provide the nature of the legal ownership (i.e., partnership, tenants in common, non-profit, corporation, etc.). If the ownership includes a corporation or partnership, include the names, titles, addresses of all individuals owning more than 10% of the shares. IF NO INDIVIDUALS OWN MORE THAN 10% OF THE SHARES, PLEASE INDICATE NON-APPLICABLE (N/A) IN THE SPACE BELOW. If a publicly-owned corporation, include the names, titles, and addresses of the corporate officers. (A separate page may be attached if necessary.) Person ·1 (l)lVlJ ~ Din \{J lo ij { Le/4-1 Corp/Part ________ _ Title __________ _ Addr8ss 1~1, ~e:fu,:;l c .Ne· Co\f\$~ad , Cft qzoog Title -------------- Address ____________ _ Page 1 of 2 Revised 07 /1 O 3. NON-PROFIT ORGANIZATION OR TRUST If any person identified pursuant to (1) or (2) above is a nonprofit organizati.on or a trust, list the names and addresses of ANY person serving as an officer or director of the non- profit organization or as trustee or beneficiary of the. Non Profit/Trust________ Non Profit/Trust _________ _ Title __________ _ Title -------------- Address __________ _ Address ____________ _ 4. Have you had more than $500 worth of business transacted with any member of City staff, Boards, Commissions, Committees and/or Council within the past twelve (12) months? D Yes ~o If yes, please indicate person(s): ___________ _ NOTE: Attach additional sheets if necessary. I certify that all the above information i9 true and correct to the best of rriy knowledge. Print or type name of owner Print or type name of applicant Signature of owner/applicant's agent if applicable/date Print or type name of owner/applicant's agent P-1 (A) Page 2 of 2 Revised 07 /1 O (760) 724-4159 DRAWING NUMBER SCALE: DATE: OWNERS NAME CONTRACTOR:DRAWN BY: APN. OF OWNERS PHONE# RONS HOUSE PLANS 8 1/4"=1'0"RTL FRONT VIEW SCALE 1/4"=1'0" LEFT SIDE SCALE 1/4"=1'0" REAR VIEW SCALE 1/4"=1'0" 6'8" EXISTING NEW NEW AREA 6'8" EXISTINGNEW NEW AREA 2 (760) 415-3660DANIELLE ALLEN 2'6" MIN. CHIMNEY TO ROOF CLEARANCE FOR A 10"0" RADIUS ABOUT THE CHIMNEY, ALSO CHECK WITH MANUFACTURER TO SEE WHAT IS THE MIN. & MAX. OPERATING HEIGHT. SPARK ARRESTORS SHALL BE INSTALLED ON ALL CHIMNEYS. ELEVATION PLAN LEGEND STUCCO [ SEE OWNER FOR COLOR & TEXTURE ] SIDING [ SEE OWNER FOR COLOR & TEXTURE ] OR OR OR OR SHADED AREA BRICK OR ROCK VENEER ROOF COVERING SEE PLAN TILE [ SEE OWNER FOR COLOR] SHUTTERS SEE OWNER WINDOWS SEE PLAN EXTERIOR FINISH: STUCCO WITH METAL LATH OVER 15# FELT MIN. AS PER C.B.C. WITH A DRIP SCREED 2" BELOW THE MUD SILL AND A MINIMUM OF 8 INCHES ABOVE GRADE AND 2" ABOVE PAVEMENT SEE OWNER FOR TYPE AND COLOR, TEXTURE, ECT. GRADE D PAPER SHALL BE USED UNDER ALL EXTERIOR WALL COVERINGS AND TWO LAYERS OF GRADE D PAPER SHALL BE APPLIED OVER ALL WOOD BASE SHEATHING. STUCCO ALL NEW SOFFITS OHAGIN ROOF VENTS 95 SQ. IN. EACH= .65 SQ. FT. ICC#9650A OHAGIN ROOF VENTS 95 SQ. IN. EACH= .65 SQ. FT. ICC#9650A EXTERIOR FINISH: STUCCO WITH METAL LATH OVER 15# FELT MIN. AS PER C.B.C. WITH A DRIP SCREED 2" BELOW THE MUD SILL AND A MINIMUM OF 8 INCHES ABOVE GRADE AND 2" ABOVE PAVEMENT SEE OWNER FOR TYPE AND COLOR, TEXTURE, ECT. GRADE D PAPER SHALL BE USED UNDER ALL EXTERIOR WALL COVERINGS AND TWO LAYERS OF GRADE D PAPER SHALL BE APPLIED OVER ALL WOOD BASE SHEATHING. 12-27-16 ALL EXTERIOR FEATURES, STUCCO ,TRIM ,COLOR, ETC.. TO MATCH EXISTING HOUSE ANY VENTS REMOVED MUST BE REPLACED BY NEW VENTS OF EQUAL OR GRATER SIZE ONLY NEW VENTS SHOWN. ANY VENTS REMOVED MUST BE REPLACED BY NEW VENTS OF EQUAL OR GRATER SIZE 14'10" + OR- 14'10" + OR- ALL VENTS CAN BE SUBSTITUTED WITH A DIFFERENT STYLE OF VENT WITH THE SAME VENTING AREA ALL ATTIC VENTILATION OPENING SHALL BE COVERED WITH CORROSION-RESISTANT METAL MESH WITH MESH OPENING OF 1/8 INCH IN EACH DIMENSION TOTAL REQUIRED= TOTAL PROVIDED = NEW ROOF VENTS: VENTS PROVIDED VENTS REQUIRED NEW HOUSE AREA ÷ 150= QUNT. TYPE AREA 0' NEW GARAGE AREA ÷ 150= 0 14"X12"VENT[.94'EA.]= 14-1/2"X24" VENTS [2.13'] = 14-1/2"X30" VENTS [3.02'] = 14 "X36" VENTS (3.2') = OHAGIN ROOF VENTS 95 SQ. IN. EACH= .65 SQ. FT. ICC#9650A = 801.0 5.34' 5.34' 9 5.85' 5.85' SCOPE OF WORK: BUILD NEW 660.75 SQ.FT. HOUSE ADDITION AND 68.0 SQ.FT. GARAGE ADDITION AND ALL THE WORK ASSOCIATED WITH ACCOMPLISHING THESE TASKS OWNER : DANIELLE & TRAVIS ALLEN PHONE # : 760 415-3660 ADDRESS & SITE ADDRESS : 4809 REFUGIO AVE. CARLSBAD CALIF. APN # : 207-350-47-00 NEW HOUSE LIVING AREA=_____660.75SQ.FT.______________ NEW PORCHES =__0'___________ NEW GARAGE=___68.0' SQ. FT.______________ _________________________ * PLANS BY RON LINVILLE 804 PIER VIEW WY SUITE 207 OCEANSIDE, CA. 92054 *ALL WORK SHALL COMPLY WITH ALL CURRENT CODES AS ADAPOTED BY THE COUNTY AND STATE OCCUPANCY= FOR HOUSE R-3, FOR THE GARAGE U TYPE OF CONSTRUCTION= V-B THIS PROJECT WILL COMPLY WITH THE FOLLOWING BUILDING CODES AND ASSOCIATED CITY AMENDMENTS: 2016 CALIFORNIA RESIDENTIAL CODE (CRC) AND OR 2016 CALIFORNIA BUILDING CODE (CBC) AS APPLICABLE 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE ( CALGREEN ) 2016 CALIFORNIA ELECTRICAL CODE (CEC) 2016 CALIFORNIA MECHANICAL CODE (CMC) 2016 CALIFORNIA PLUMBING CODE (CPC) 2016 CALIFORNIA FIRE CODE (CFC) 2016 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS (CBEES) 6'8" EXISTINGNEW NEW AREA 14'10" + OR- PLOT PLAN ELEVATIONS EXISTING FLOOR PLAN TITLE 24 & ENERGY FOUNDATION PLAN ELECTRICAL PLAN CAL GREEN& NOTES & DETAILS 1 2 3 4 5 6 7 8 PAGE #CONTENT TABLE OF CONTENTS ROOF PLAN NEW FLOOR PLAN ATTACHED #2633-2750 (760) 724-4159 DRAWING NUMBER SCALE: DATE: OWNERS NAME CONTRACTOR:DRAWN BY: APN. OF OWNERS PHONE# RONS HOUSE PLANS 3 8 1/4"=1'0" (760) 415-3660DANIELLE ALLEN RTL WINDOW, SLIDING, GLASS DOOR OR MIRROR DOOR NEW FULL HEIGHT WALLS EXISTING FULL HEIGHT WALLS SHELF AND POLE HANDRAIL OR PARTIAL WALL HEADER OR WALL OPENINGS RETAINING WALLS FLOOR PLAN LEGEND EXISTING FLOOR PLAN SCALE 1/4" = 1'0" 54' 19'14'6'15' 25' 9' 13' 47' 52' 5' 52' 4'11' 12' 2' 2'6" 12'6" 8'26'20' 54' 6'6" 5'0"X3'0" SHOWER W/TEMP GLASS 5'0"X2'6"TUB &SHOWER5'6" 3'6" 4'16' EXISTING HOUSE LIVING AREA=_____________________ DECKS PORCHES =_____________ GARAGE=_________________ 2 6 26 26 LINENEXISTING 6'0"X6'8" SL EXISTING 2'0"X3'0" SL EXISTING 2'0"X3'0" SL EXISTING 4'0"X2'0" SL EXISTING 4'0"X1'0" SL26 3 0 3 0 1'6"16' 1'6" 2' 17'6" 12'6" 9' 16 26 FAU 36" FP4'6"4' 20'6" 4'6" 5'4'7' EXISTING 4'0"X3'6" SL EXISTING 12'0"X6'8" SL 26 26 20'6" GARAGE SERVICE KITCHEN LIVING ROOM FAMILY ROOM DINING ROOM BEDROOM #2 BEDROOM#3 MASTER SUITE ENTRY PORCH STORAGE 24 4' 6'6" 416.25 ft2 1618.75 ft2DWREFG.RANGE EXISTING 200 AMP. METER PANEL AND SERVICE ENTRANCE. NO CHANGE GAS METER 12-27-16 (760) 724-4159 DRAWING NUMBER SCALE: DATE: OWNERS NAME CONTRACTOR:DRAWN BY: APN. OF OWNERS PHONE# RONS HOUSE PLANS 4 8 1/4"=1'0" 12-27-16 (760) 415-3660DANIELLE ALLEN RTL WINDOW, SLIDING, GLASS DOOR OR MIRROR DOOR NEW FULL HEIGHT WALLS EXISTING FULL HEIGHT WALLS SHELF AND POLE HANDRAIL OR PARTIAL WALL HEADER OR WALL OPENINGS RETAINING WALLS FLOOR PLAN LEGEND NEW FLOOR PLAN SCALE 1/4" = 1'0" 54' 19'14'6'15' 25' 47' 52' 5' 52' 4'11' 12' 2' 2'6" 12'6" 8'26'20' 54' 6'6" 3'6"X3'0" SHOWER W/TEMP GLASS 5'0"X2'6"TUB &SHOWER5'6" 3'6" 4'16' 2 6 26 26 LINENEXISTING 6'0"X6'8" SL REMOVE EXISTING 2'0"X3'0" SL EXISTING 4'0"X2'0" SL EXISTING 4'0"X1'0" SL26 3 0 3 0 1'6" 16' 1'6" 2' 9' 16 26 FAU 36" FP4'6"4' 20'6" 4'6" 5'4'7' REMOVE WINDOW LEAVE CASED OPENING NEW 16'0"X6'8" SL 26 26 20'6" GARAGE KITCHEN LIVING ROOM DINING ROOM BEDROOM #2 BEDROOM#3 MASTER SUITE ENTRY PORCH STORAGE 24 4' 6'6" 416.25 ft2 1618.75 ft2 42'6" 13' 9' 22' SERVICE 16'6"9'6" 26' NEW BEDROOM #4 WASHER DRYER NEW FAMILY ROOM 660.75 ft2 8'6" 4'6" 17'6" NEW 2'0"X3'0" SL NEW 2'0"X3'0" SL 6'6" 3'6" 8' 5'6"DWREFG.RANGEOR ALL OPEN 12'6" 17'6" 3' 10' 3' 16'6" NEW 12'0"X6'8" SL 3'W/HWATER HEATER TANKLESS RHEEM W14-7/8"X D11-1/8" X H25-3/8" MIN. 12" ABOVE GROUND SHOWER W/TEMP GLASS NEW 2'0"X3'0" SH 8'6" 8'6" 3'6" 7' 3'9" 3'6" 5'6" 3'9"12'9" 2' 11'1'9" NEW 3'0"X3'6" SL 4'6" 1'28 28 4'6" 1'6" 8'3"+OR- CEILING 8'3/4" CEILING 8'3/4" CEILING 8'3/4" CEILING 8'3/4" CEILING 8'3/4" CEILING 8'3/4" CEILING 8'3"+OR- CEILING 8'3/4" CEILING 8'3/4" CEILING 8'3/4" CEILING 8'3/4" CEILING NEW GIRDER TRUSS MOVE EXISTING 200 AMP. METER PANEL AND SERVICE ENTRANCE. NO CHANGE GAS METER SHELVES & SHOES 2 6 26 4' LINEN24 8' 30' 4'9"5'3"16' 5'6" REMOVE EXISTING 2'0"X3'0" SL 4' 4'6" 68.00 ft2 EXISTING HOUSE LIVING AREA=_____________________ NEW AREA =_____________ EXISTING GARAGE=_________________ NEW GARAGE=_________________ A 5 A 5 DRYER VENT TO TERMINATE ON THE ROOF. DRYER VENT [4"MIN.] 14' MAX. LENGTH, COMBINED HORIZONTAL & VERTICAL INCLUDING [2] 90 DEG. ELEBOWS AND SHALL BE EQUIPPED WITH BACK-DRAFT DAMPERS AND MUST TERMINATE A MIM. 3' FROM ANY OPENING. SECTION 504.3.2 U.M.C. FOR EGRESS DOORS: MAX . 7.75 INCHES FOR IN-SWINGING DOORS FROM TOP OF THRESHOLD TO LANDING AND 1.5 INCHES FOR OUT-SWINGING FOR NON-REQUIRED DOORS: IN OR OUT SWINGING 7.75 INCHES LANDINGS AT DOORS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF DOOR AND LENGTH IN THE DIRECTION OF TRAVEL OF NOT LESS THAN 36", WILL BE PROVIDED ON EACH SIDE OF DOORS. THE ELEVATION OF LANDING SHALL NOT EXCEED ONE INCH DIFFERENCE THAN THE THRESHOLD OF THE DOORWAY[ 8" IF DOOR DOES NOT SWING OVERT THE LANDING]. ALL LANDINGS SHALL SLOPE AWAY FROM THE DOOR MIN 1/4" PER FOOT. ALL LUMBER AND PLYWOOD WILL BE GRADE STAMPED BY AN APPROVED INSPECTION ANGENCY. ALL STRUCTURAL MATERIALS OF CONSTRUCTION TO COMPLY WITH THE CODE [CBC] TWO LAYERS OF GRADE D PAPER SHALL BE APPLIED OVER ALL WOOD BASE SHEATHING. THESE PLANS AND ALL WORK SHALL COMPLY WITH THE CALIFORNIA BUILDING STANDARDS CODE FOUND IN STATE OF CALIFORNIA TITLE 24 CCR CHECK WITH OWNER FOR COFFERED CEILINGS,LIGHT SOFFITS, SOFFITS FOR HEAT VENTS, CABINETS SHOWERS,TUBS, ECT. OWNER TO CHECK WITH THE HEATING CONTRACTOR FOR THE PLACEMENT OF THE HEATING DUCTS. AND THE AREA REQUIRED TO BE SOFFITED OR FURRED DOWN. ALL NEW GLAZING [ FENESTRATIONS ] WILL BE INSTALLED WITH A CERTIFYING LABEL ATTACHED, SHOW THE U VALUE. CHECK WITH PLUMBING CONTRACTOR FOR ANY PLUMBING WALLS THAT WOULD NEED TO BE A 6" WALL. CHECK WITH THE OWNER FOR OPTIONAL 6" EXTERIOR WALLS. INSTALL WATER FOR ICE MAKER IN THE REFRIGERATOR AREA. TUB AND SHOWER TO HAVE TILE INSTALLED 70" HIGH ABOVE THE FLOOR MIN. PROVIDE LOW FLUSH TOILETS (1.28GAL.) ALL WATER CLOSETS INSTALLED ON THIS PROJECT TO BE STATE OF CALIFORNIA, DEPARTMENT OF HOUSING & COMMUNITY DEVELOPMENT APPROVED LOW WATER CONSUMPTION TYPE MAXIMUM 1.6 GALLONS PER FLUSH ALL WATER HEATERS REQUIRE A MINIMUM OF 2 STRAPS [ ONE STRAP AT TOP 1/3 OF THE TANK AND ONE STRAP AT BOTTOM 1/3 OF TANK] TO RESIST HORIZONTAL DISPLACEMENT. STRAPS TO BE A MINIMUM OF 3/4" X24 GAUGE STRAPS WITH 1/4" X 3" LAG BOLTS ATTACHED DIRECTLY TO THE FRAMING [C.P.C. SEC 508.2] SPECIFY 15# FELT UNDER WOOD SIDING IN SHOWERS AND TUB-SHOWER COMBINATIONS, CONTROL VALVES MUST BE PRESSURE BALANCED OR THERMOSTATIC MIXING VALVES. CBC * BALLOON FRAME ALL WALLS OF ROOMS WITH SLOPING CEILINGS * MAXIMUM UNBRACED HEIGHT OF LATERALLY UNSUPPORTED, 2X4,3X4,2X6, STUDS IS 10'0" FOR BEARING WALLS * MAXIMUM UNBRACED HEIGHT OF LATERALLY UNSUPPORTED STUDS FOR NON-BEARING WALLS IS AS FOLLOWS: [A] 2X4 AND 3X4 IS 14' [B] 2X6] IS 20' DOUBLE TOP PLATE TO HAVE A MIN. 48" LAP SPLICE ALL DOOR HEADER TO BE 4X10 UNLESS NOTED OTHERWISE CROSS BRIDGING OR BLOCKING AT FLOOR JOISTS AND RAFTERS 12" OR MORE IN DEPTH SHALL BE SUPPORTED LATERALLY BY BRIDGING AT INTERVALS NOT EXCEEDING 8'0" , UNLESS BOTH EDGES ARE HELD INLINE. IN 2-STORY BUILDINGS, SHEAR PANELS AT THE FIRST STORY [AT LEAST 48" IN WIDTH] SHALL BE LOCATED AT EACH END OR AS NEAR THERETO AS POSSIBLE AND COMPRISE AT LEAST 25 PERCENT OF THE LINEAR LENGTH OF THE WALL, OR PROVIDE DESIGN. WINDOW AREA MUST BE 8% OF THE FLOOR AREA, OF THE ROOM SERVED (C.B.C.1205.2). TEMPERED SAFETY GLASS IS REQUIRED PER CBC 2406.4 1]IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS. GLAZING IN ANY PORTION OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60" ABOVE A STANDING SURFACE AND DRAIN INLET. 2] IN FIXED OR OPERABLE PANELS ADJACENT TO A DOOR WHERE THE NEAREST EXPOSED EDGE OF THE GLAZING IS WITHIN A 24" ARC OF EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60" ABOVE THE WALKING SURFACE. HINGED SHOWER DOORS MUST SWING OUTWARD. THRESHOLDS TO BE WIDE ENOUGH FOR A MINIMUM 22" WIDE DOOR AND 22" WIDE MAINTAINED EGRESS. OPENABLE WINDOW AREA TO THE OUTDOORS OF AT LEAST 4% OF THE ROOM SERVED (C.B.C.1203.4). SLEEPING ROOMS AND BASEMENTS MUST HAVE AN EXTERIOR EGRESS DOOR OR WINDOW [CBC 1026.2, 1026.3, 1026.5 ] WITH: (U.B.C. SEC. 310.4 ) : A) 5.7 SQ. FT. MINIMUM NET CLEAR OPENABLE AREA [ 5.0 SQ. FT.. FOR GRADE-LEVEL OPENINGS ] B) 24" MINIMUM NET CLEAR OPENABLE HEIGHT, C) 20" MINIMUM NET CLEAR OPENABLE WIDTH, D) BOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44" ABOVE FLOOR, E) DIRECT OPENING TO PUBLIC WAY OR YARD/COURT OPENING TO PUBLIC WAY, F) WINDOW WELLS OF 9 SQ. FT.. HORIZONTAL AREA AND 36" MINIMUM DIMENSIONS AND EQUIPPED WITH LADDERS/ STEPS FOR ESCAPE. PRIOR TO CONSTRUCTION THE FRAMING CONTRACTOR AND THE HEATING CONTRACTOR ARE TO DETERMINE WHERE THE HEATING DUCTS, RETURN AIR, ECT. ARE TO GO. DOUBLE TOP PLATE TO HAVE A 48" MIN. LAP SPLICE PROVIDE 8-16d LAP SPICE NAILING MIN. CBC. 2308.9.2.1. WHERE TOP PLATES OR SOLE PLATES ARE CUT FOR PIPES, A METAL TIE MINIMUM OF "0.058" INCHES THICK AND "1-1/2" INCHES WIDE SHALL BE FASTENED ACROSS THE OPENING WITH 6-16d NAILS MINIMUM EACH SIDE. CBC FIRE STOPS AT THE FOLLOWING LOCATIONS PER CBC 708. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND AT 10' FOOT INTERVALS ALONG THE LENGTH OF THE WALL; B. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS AND COVE CEILINGS; C. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN AND BETWEEN STUDS ALONG AND INLINE WITH THE RUN OF STAIRS IF THE WALLS UNDER THE STAIRS ARE UNFINISHED; AND D. IN OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS, FIREPLACES AND SIMILAR OPENINGS WHICH AFFORD A PASSAGE FOR FIRE AT CEILING AND FLOOR LEVELS, WITH NONCOMBUSTIBLE MATERIALS. E. AT OPENINGS BETWEEN ATTIC SPACES AND CHIMNEY CHASES FOR FACTORY-BUILT CHIMNEYS . THE PLUMBING FIXTURES AND PLUMBING FITTINGS SHALL MEET THE STANDARDS NOTED BELOW TO MEET THE CAL GREEN 20% INDOOR WATER SAVINGS: 1] WATER CLOSET, GRAVITY TANK-TYPE, FLUSHOMETER TANK TYPE, ELECTROMECHANICAL HYDRAULIC TYPE = 1.28 GALLONS PER FLUSH MAX. 2] SHOWER HEAD = 2.0 GPM MAX. 3] KITCHEN FAUCETS = 1.8 GPM MAX. 4]LAVATORY FAUCETS= 1.5 GPM MAX. 5] URINALS .5 GALLONS PER FLUSH ] IN SHOWERS AND TUB-SHOWER COMBINATIONS, CONTROL VALVES MUST BE PRESSURE BALANCED OR THERMOSTATIC MIXING VALVES. CPC 6]PERMANENT VACUUM BREAKERS SHALL BE INSTALLED WITH ALL NEW HOSE BIBS. TEMPERED GLASS TEMPERED GLASS TEMPERED GLASS TEMPERED GLASS TEMPERED GLASS GENERAL NOTES 1. DIMENSIONS DERIVED FROM PREVIOUS PLANS PROVIDED BY THE OWNER. 2. FIELD VERIFY DIMENSIONS PRIOR TO ENGINEERING, CONSTRUCTION & SUBMITTING FOR PERMITS. 3. BUILDING PERMIT SUBMITTAL & APPROVAL REQUIRED PRIOR TO ANY MODIFICATION OR CONSTRUCTION WHICH IS REQUIRED TO MEET CURRENT BUILDING CODES & REGULATIONS IN THE ZONED AREA OF SUBJECT PROPERTYATTICACCESS22"X36" (760) 724-4159 DRAWING NUMBER SCALE: DATE: OWNERS NAME CONTRACTOR:DRAWN BY: APN. OF OWNERS PHONE# RONS HOUSE PLANS 5 8 1/4"=1'0" (760) 415-3660DANIELLE ALLEN RTL 54' 19'14'6'15' 25' 47' 52' 5' 52' 4'11' 12' 2' 2'6" 12'6" 8'26'20' 54' 6'6" 5'6" 3'6" 4'16' 1'6" 16' 1'6" 2' 9' FAU 4'6"4' 20'6" 4'6" 5'4'7' 20'6" 24 4' 6'6" 42'6" 13' 9' 22' 26'8'6" 4'6" 17'6" 6'6" 3'6" 8' 5'6" 12'6" 17'6" 3' 10' 3' 16'6" 3' 8'6" 7' 3'9" 3'6" 6' 3'9"12'9" 2' 11'1'9" 4' 1'6" 4'6" 1'6" ROOF COVERING: ELK PREMIUM ROOFING FIBERGLASS SHINGLES OVER 2 LAYERS 15# FELT ICBO #ESR-1475 INSTALLED AS PER MANUFACTURES SPECIFICATIONS TIMBERLINE COOL SERIES - BARKWOOD INITIAL SOLARREFLECTANCE = 0.27 THERMAL EMITTANCE = 0.92 SOLAR REFLECTANCE INDEX (SRI) = 29 LEED® CREDITS =YES CRRC # 0676-0041 ROOF SHEATHING: 1/2" WOOD STRUCTURAL PANEL P II 24/0 NAILED C-D UNBLOCKED W / 8d COMMON@ 6" O.C. E.N. & 12" O.C. F.N. & 1X6 T& G ON ALL OVERHANG GIRDER TRUSS EXISTING 4 TO 12 NEW 2 TO 12 B 9 EXISTING CLIPPED END NEW EXISTING R-30 INSULATION R-21 INSULATION FOR THE 6" WALLS AND R-13 FOR THE 4" WALLS REMOVE WALL A 8'3/4" CEILING 12-27-16ATTICACCESS22"X36"8' 3'6" 30' 5'6" 4'9"5'3"16' 4'4'6" 1 1 L=5'0" L=5'0" L=5'6" 1 L=6'6" 1 L=8'0" 1 L=8'6" 1 L=8'0" ALL SHEAR WALLS TO EXTEND TO THE ROOF SOLID SHEATH ENTIRE NEW ADDITION WITH 3/8" PLYWOOD [C-D,C-C,OR STRUCT.II] NAILED WITH 8d @6" 0.C. B.N. & 12" 0.C. F.N. EXECPT WHERE OCCURS 1 1 L=4'75"L=5'25" 1 L=4'0" 1L=11'0" COOL ROOF REQUIRED ROOF PLAN SCALE 1/4" =1'0" EXPOSED VALLEY FLASHINGS SHALL BE AT LEAST NO. 26-GUAGE CORROSION-RESISTANT METAL INSTALLED OVER A MINIMUM 36" WIDE UNDERLAYMENT CONSISTING OF ONE NO. 72 ASTM CAP SHEET RUNNING THE FULL LENGTH OF THE VALLEY. "EACH TRUSS SHALL BE LEGIBLY BRANDED, MARKED OR OTHERWISE HAVE PERMANENTLY AFFIXED THERETO THE FOLLOWING INFORMATION LOCATED WITHIN 2 FEET OF THE CENTER OF THE SPAN ON THE FACE OF THE BOTTOM CHORD: A)IDENTITY OF THE COMPANY MANUFACTURING THE TRUSS.B)THE DESIGN LOAD. C)THE SPACING OF THE TRUSSES." 2" x RIDGE BLOCKING FOR DIAPHRAGM NAILING. CONTRACTOR TO CHECK ALL MEASUREMENTS IN THE FIELD PRIOR TO ORDERING TRUSSES ROOFING SHALL HAVE A MINIMUM CLASS "A" RATING ALL ROOFING MATERIALS TO BE APPLIED AS PER MANUFACTURES SPECIFICATIONS ALL FLASHING, WATERPROOFING, UNDRLAYMENTS, ECT. TO BE APPLIED AS PER MANUFACTURES SPECIFICATIONS AND TO CODE. 2'0" MIN. CHIMNEY TO ROOF CLEARANCE FOR A 10.0" RADIUS ABOUT THE CHIMNEY, ALSO CHECK WITH MANUFACTURE TO SEE WHAT IS THE MIN. & MAX. OPERATING HEIGHT TRUSSES TO HAVE A 2X6 (OPTIONAL) TOP CHORD 1/2" CLEARANCE BETWEEN TRUSSES AND NON-BEARING WALLS AND USE TRUSS CLIPS AT ALL PERPENDICULAR PARTITION WALLS CALIF. FILL @ 24"O.C. SEE TRUSS CO. DETAILS ENG. TRUSSES @ 24" O.C. ENG. TRUSSES @ 24" O.C. ENG. TRUSSES @ 24" O.C. CALIF. FILL @ 24"O.C. SEE TRUSS CO. DETAILS ONLY NEW ROOF SHOWN ADDITION : OVERHANGS TO MATCH THE EXISTING OVERHANGS. ROOF PITCH TO MATCH THE EXISTING ROOF. FASCIA TO MATCH EXISTING. THESE FIGURES ARE ESTIMATES AND WILL HAVE TO BE VERIFIED IN THE FIELD BY THE CONTRACTOR PRIOR TO STARTING CONSTRUCTON. . SHADED AREAS TO BE CALIF. FILL OVERHANGS: ALL OVERHANGS GABLE ENDS AND TOWERS AND BAYS LENGTH TO BE ADJUSTED IN THE FIELD TO MATCH THE MAIN ROOF. THE FASCIA TO MATCH THE MAIN ROOFGIRDER TRUSS4X10 FLUSH SIMPSON HANGERS ENG. TRUSSES @ 24" O.C. CMST16 ON 4X4 OR GIRDER TRUSS L=17' 6X16 HDR 6X16 HDR 4X6 HDR 4X6 HDR 4X6 HDR 4X6 HDR 4X8 HDR 4X6 POST 4X6 POST GENERAL NOTES 1. DIMENSIONS DERIVED FROM PREVIOUS PLANS PROVIDED BY THE OWNER. 2. FIELD VERIFY DIMENSIONS PRIOR TO ENGINEERING, CONSTRUCTION & SUBMITTING FOR PERMITS. 3. BUILDING PERMIT SUBMITTAL & APPROVAL REQUIRED PRIOR TO ANY MODIFICATION OR CONSTRUCTION WHICH IS REQUIRED TO MEET CURRENT BUILDING CODES & REGULATIONS IN THE ZONED AREA OF SUBJECT PROPERTY SIMPSON ST6224 @ SOLE PLATE, TOP PLATE, &24" O.C. SIMPSON ST6224 @ SOLE PLATE, TOP PLATE, &24" O.C. SIMPSON ST6224 @ SOLE PLATE, TOP PLATE, &24" O.C. MST48 4X6 HDR SIMPSON ST6224 @ SOLE PLATE, TOP PLATE, &24" O.C. (760) 724-4159 DRAWING NUMBER SCALE: DATE: OWNERS NAME CONTRACTOR:DRAWN BY: APN. OF OWNERS PHONE# RONS HOUSE PLANS 6 8 1/4"=1'0" (760) 415-3660DANIELLE ALLEN RTL 54' 19'14'6'15' 25' 47' 52' 5' 52' 4'11' 12' 2' 2'6" 12'6" 8'26'20' 54' 6'6" 5'6" 3'6" 4'16' 26 1'6" 16' 1'6" 2' 9' FAU 4'6"4' 20'6" 4'6" 5'4'7' 20'6" 24 4' 6'6" 42'6" 13' 9' 22' 16'6"9'6" 26'8'6" 4'6" 17'6" 6'6" 3'6" 8' 5'6" 12'6" 17'6" 3' 10' 3' 16'6" 3' 8' 8'6" 7' 3'9" 6' 3'9"12'9" 2' 11'1'9" 4' 1'6" 4'6" 1'6" GIRDER TRUSS 12-27-16 3'6" 30' 5'6" 4'4'6" 4'9"5'3"16' 1 1 1 L=5'0" L=5'6" 1 L=6'6" 1 L=8'0" 1 L=8'6" 1 L=8'0" ALL SHEAR WALLS TO EXTEND TO THE ROOF SOLID SHEATH ENTIRE NEW ADDITION WITH 3/8" PLYWOOD [C-D,C-C,OR STRUCT.II] NAILED WITH 8d @6" 0.C. B.N. & 12" 0.C. F.N. EXECPT WHERE OCCURS 1 ALL SHEAR WALLS TO HAVE 5/8" X 10" A.B. 7" INTO CONC. @2'0" O.C. W/ NUT & WASHERS INSTALLED. MIN. 2 EACH PANEL STHD10 STHD10 STHD10 STHD10 STHD10 STHD10 1 L=4'0" 1 L=4'75" L=5'25" STHD10 STHD10 STHD10 1L=11'0" STHD10 4X8 HDR 4X6 POST 4X6 POST 48"X48"X18"" W/ (4) #5 BARS E.W. 48"X48"X18"" W/ (4) #5 BARS E.W. CONTRACTOR TO CHECK FOR POST-TENSIONED FOUNDATION AND CONTACT ENGINEER IF FOUND. IF THIS IS A POST-TENSIONED FOUNDATION CAREFUL ATTENTION MUST BE TAKEN NOT TO DAMAGE THE POST-TENSION CABLES. IF ANY DAMAGE TO THE CABLES OCCURS CONTACT THE ENGINEER IMMEDIATELY. ADDITION FLOOR HEIGHT IN THE ADDITION TO MATCH UP WITH THE EXISTING HOUSE FLOOR. ONLY NEW FOUNDATION SHOWN DOWELS #5 BARS 30"LONG @2'0" O.C. 6"INTO EXISTING FOUNDATION& PACKED WITH SIMPSON SET-XP ICC-ES ESR-2508 DOWELS #5 BARS 30"LONG @2'0" O.C. 6"INTO EXISTING FOUNDATION& PACKED WITH SIMPSON SET-XP ICC-ES ESR-2508 4" CONC. SLAB FLOOR W/ /#3 BARS @ 18" O.C EW OVER 4" OF SAND FILTER W/ 6 MIL. VISQUEEN MEMBRANE IN CTR OF SAND. SAW CUT SLAB @ 10'0" O.C.E.W. DOWELS #5 BARS 30"LONG @2'0" O.C. 6"INTO EXISTING FOUNDATION& PACKED WITH SIMPSON SET-XP ICC-ES ESR-2508 4" CONC. SLAB FLOOR W/ /#3 BARS @ 18" O.C EW OVER 4" OF SAND FILTER W/ 6 MIL. VISQUEEN MEMBRANE IN CTR OF SAND. SAW CUT SLAB @ 10'0" O.C.E.W. *CONCRETE TO BE 2500 PSI @ 28 DAYS MIN. 8" MIN 18" 12" 4" SAND 2X STUDS @ 16" OC NAT. SOIL 4" CONC SLAB ( 2 ) #5 BAR TOP&BOTTOM GRADE 40 STEEL 3" MIN. MIN. 3" 2X PRESSURE TREATED MUD SILL ALL FOUNDATION BOLTS MUST BE HOT DIPPED ZINC COATED GALVANIZED MIN. FOUNDATION BOLTS. MIN. OF TWO 5/8" DIA. . X 14" [ 9" MIN. EMBEDMENT ] BOLTS WITH 3" X 3" X 0.229" STEEL PLATE WASHERS ON EACH ANCHOR BOLT, 4" MIN. & 12" MAX. FROM EACH END AND MAXIMUM SPACING = 4'0". HOLD DOWN HARDWARE MUST BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION.SURFACE WATER WILL DRAIN AWAY FROM BUILDING. THE GRADE SHALL FALL A MINIMUM OF 5% WITHIN THE FIRST 10 FEET[ 2% FOR IMPERVIOUS SURFACES]. SECTION 1803.3 4" CONC. SLAB W/ #3 BARS @ 18" O.C. E.W. OVER 6 MIL VISQUEEN MEMBRANE OVER 4" OF SAND & SAW CUT SLAB @ 10'0" O.C.E.W. A *CONTRACTOR TO COMPLY WITH ALL THE SOIL REPORT RECOMMENDATIONS * ALL HOLDDOWNS MUST BE TIED IN PLACE PRIOR TO FOUNDATION INSPECTION * INSPECTOR WILL RECHECK FOR EXPANSIVE SOIL OR GRADING REQUIREMENTS AT FIRST INSPECTION. * CONTRACTOR TO CHECK FOR CORRECT PLACEMENT OF ALL HOLDDOWNS & CORRECT POST CONNECTORS * CONTRACTOR TO CHECK WITH AN ENGINEER FOR STRUCTURAL INTEGRITY AND LOCAL CODES PRIOR TO PLACEMENT OF CONCRETE * SEE SIMPSON CATALOG FOR INSTALLATION OF ALL HOLDDOWNS * MINIMUM DISTANCE FROM FOUNDATION TO DAYLIGHT TO BE H/3 OR 7'0" WHICHEVER IS GREATER. * ALL CONCRETE TO BE DONE IN A MONOLITHIC POUR FOUNDATION PLAN SCALE 1/4" =1'0" A 6 B 6 A 6 A 6 A 6 C 6 D 6 FLOOR HEIGHT IN THE ADDITION TO MATCH UP WITH THE EXISTING HOUSE FLOOR. 4" SAND W/ 6 MIL VISQUEEN MEMBRANE CTR. OF SAND OR EXISTING CONC. SLAB 2X STUDS @ 16" OC NAT. SOIL DRYWALL EACH SIDE 4" CONC SLAB SEE PLAN EXISTING 4" CONC SLAB C ** SEE SOILS REPORT * ( 2 ) #5 BAR TOP&BOTTOM 3" MIN. MIN. 3" 2X PRESSURE TREATED MUD SILL *CONCRETE TO BE 2500 PSI @ 28 DAYS MIN. 4" CONC. SLAB W/ #3 BARS @ 18" O.C. E.W. OVER 4" OF SAND & SAW CUT SLAB @ 10'0" O.C.E.W. ALL FOUNDATION BOLTS MUST BE HOT DIPPED ZINC COATED GALVANIZED MIN. FOUNDATION BOLTS. MIN. OF TWO 5/8" DIA. . X 14" [ 9" MIN. EMBEDMENT ] BOLTS WITH 3" X 3" X 0.229" STEEL PLATE WASHERS ON EACH ANCHOR BOLT, 4" MIN. & 12" MAX. FROM EACH END AND MAXIMUM SPACING = 4'0". HOLD DOWN HARDWARE MUST BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION. 8" 18" MIN. 15"CUT EXISTING SLAB AND ADD NEW FOOTING B 8" 18" 12" ( 2 ) #5 BAR TOP&BOTTOM 2X STUDS @ 16" NAT. SOIL 1/2" DRYWALL EACH SIDE 4" CONC 6 MIL VISQUEEN MEMBRANE CTR. OF SAND 2X PRESSURE TREATED MUD SILL * SEE SOILS REPORT * 3" MIN. MIN. MIN. 3" *CONCRETE TO BE 2500 PSI @ 28 DAYS MIN. ALL FOUNDATION BOLTS MUST BE HOT DIPPED ZINC COATED GALVANIZED ALL FOUNDATION BOLTS MUST BE HOT DIPPED ZINC COATED GALVANIZED MIN. FOUNDATION BOLTS. MIN. OF TWO 5/8" DIA. . X 14" [ 9" MIN. EMBEDMENT ] BOLTS WITH 3" X 3" X 0.229" STEEL PLATE WASHERS ON EACH ANCHOR BOLT, 4" MIN. & 12" MAX. FROM EACH END AND MAXIMUM SPACING = 4'0". HOLD DOWN HARDWARE MUST BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION. 4" CONC. SLAB W/ #3 BARS @ 18" O.C. E.W. OVER 6 MIL VISQUEEN MEMBRANE OVER 4" OF SAND & SAW CUT SLAB @ 10'0" O.C.E.W. ( 2 ) #5 BAR TOP&BOTTOM GRADE 40 STEEL 4" CONC. SLAB W/ #3 BARS @ 18" O.C. E.W. OVER 6 MIL VISQUEEN MEMBRANE OVER 4" OF SAND & SAW CUT SLAB @ 10'0" O.C.E.W. 18" 15" 2X PRESSURE TREATED MUD NAT. SOIL 8" 4" CONC. SLAB D NO STEM WALL WHERE DOORS OR OPENINGS OCCUR * SEE SOILS REPORT * MIN MIN MIN 3" *CONCRETE TO BE 2500 PSI @ 28 DAYS MIN. 3" 8" SURFACE WATER WILL DRAIN AWAY FROM BUILDING. THE GRADE SHALL FALL A MINIMUM OF 5% WITHIN THE FIRST 10 FEET[ 2% FOR IMPERVIOUS SURFACES]. SECTION 1803.3 ALL FOUNDATION BOLTS MUST BE HOT DIPPED ZINC COATED GALVANIZED MIN. FOUNDATION BOLTS. MIN. OF TWO 5/8" DIA. . X 14" [ 9" MIN. EMBEDMENT ] BOLTS WITH 3" X 3" X 0.229" STEEL PLATE WASHERS ON EACH ANCHOR BOLT, 4" MIN. & 12" MAX. FROM EACH END AND MAXIMUM SPACING = 4'0". HOLD DOWN HARDWARE MUST BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION. WASHER DRYER NEW 3'0"X3'6" SL SHELVES & SHOES 2 6 26 LINEN24 (760) 724-4159 DRAWING NUMBER SCALE: DATE: OWNERS NAME CONTRACTOR:DRAWN BY: APN. OF OWNERS PHONE# RONS HOUSE PLANS 7 8 1/4"=1'0" (760) 415-3660DANIELLE ALLEN RTL 3'6"X3'0" SHOWER W/TEMP GLASS 5'0"X2'6"TUB &SHOWER2 6 26 26 LINENEXISTING 6'0"X6'8" SL EXISTING 2'0"X3'0" SL EXISTING 2'0"X3'0" SL EXISTING 4'0"X2'0" SL EXISTING 4'0"X1'0" SL26 3 0 3 0 16 26 FAU 36" FP NEW 16'0"X6'8" SL 26 GARAGE KITCHEN LIVING ROOM DINING ROOM BEDROOM #2 BEDROOM#3 MASTER SUITE ENTRY PORCH STORAGE 24 SERVICE NEW BEDROOM #4 WASHER DRYER NEW FAMILY ROOM 2 6 NEW 2'0"X3'0" SL NEW 2'0"X3'0" SL DWREFG.RANGENEW 12'0"X6'8" SL W/HWATER HEATER TANKLESS RHEEM W14-7/8"X D11-1/8" X H25-3/8" MIN. 12" ABOVE GROUND NEW 2'0"X3'0" SH 28 28 8'3"+OR- CEILING 8'3/4" CEILING 8'3/4" CEILING 8'3/4" CEILING 8'3/4" CEILING 8'3/4" CEILING 8'3/4" CEILING 8'3"+OR- CEILING 8'3/4" CEILING 8'3/4" CEILING 8'3/4" CEILING NEW GIRDER TRUSS 12-27-16 NEW HEAT DUCT NEW HEAT DUCT USE EXISTING FAU NEW HEAT DUCT NEW HEAT DUCT 26 EXH. FAN PROVIDING TEN AIR CHANGES PER HOUR DUCTLESS FANS ARE NOT ACCEPTABLE DISCHARGE POINT FOR EXHAUST AIR TO BE AT LEAST 3 FEET FROM ANY OPENING WHICH ALLOWS AIR ENTRY INTO OCCUPIED PORTIONS OF THE BUILDING NUTONE #ZN110HL DUCT AS PR MANUFACTURES SPEC. 110 CFM ENERGY STAR RATED ULTRA GREEN W/ HUMIDISTAT & MOTION SENSING SOUND RATING 0.3 SONES UL APPROVED FOR OVER TUBS OR SHOWERS 220V VS 0SP F-S WPGFCI S ALL ROOMS AND OUTDOOR LIGHTING TO HAVE HIGH EFFICACY LIGHT FIXTURES [ FLUORESCENT WITH GU24 SOCKETS ] NO MEDIUM BASE INCANDESCENT LAMP SOCKETS ARE PERMITTED FOR HIGH EFFICACY LIGHT FIXTURES ALL ELECTRICAL WORK TO BE DONE AS PER CEC. ALL APPLIANCES TO HAVE SEPARATE DEDICATED CIRCUITS AND SIZED ACCORDING TO THE APPLIANCE SPECIFICATIONS SUCH AS , REFG., DISHWASHER, TRASH COMPACTOR, GARBAGE DISP., OVEN, RANGE, MICROWAVE, FAU., AIR COND., VAC., ECT. THE ELECTRICIAN TO CHECK WITH THE OWNER FOR THE PLACEMENT AND NUMBER OF TELEVISION, TELEPHONE, & INTERCOM OUTLETS. TELEVISION, PHONE & TELEPHONE OUTLETS IN EVERY ROOM CHECK WITH OWNER FOR PLACEMENT * ALL BATHROOMS AND KITCHENS TO HAVE FLUORESCENT [40 LUMENS PER WATTOR GREATER] GENERAL LIGHTING PER CEC, TITLE 24 FIXTURES MUST BE OF THE BALLASTED TYPE THAT CAN ONLY ACCEPT FLUORESCENT BULBS. NOTE: PER THE 2013 CEC ELECTRICAL CODE ARTICLE 210.12 ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION IS REQUIRED IN ALL 120-VOLT, SINGLE PHASE, 15- AND 20-AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS. ALL NEW CONSTRUCTION, INTERIOR OR EXTERIOR ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A PERMIT AND HAVING A VALUATION IN EXCESS OF $1,000, AND APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED IN DWELLING UNITS THAT AND IN SLEEPING UNITS WITHIN WHICH FUEL-BURNING APPLIANCES ARE INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES SHALL BE PROVIDED WITH A CARBON MONOXIDE ALARM A. CARBON MONOXIDE ALARMS SHALL ONLY BE REQUIRED IN THE SPECIFIC DWELLING UNIT OR SLEEPING UNIT FOR WHICH THE PERMIT WAS OBTAINED. CARBON MONOXIDE ALARMS REQUIRED BY THE CEC AND SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS. B. OUTSIDE OF EACH SEPARATE DWELLING UNIT SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM[S] C. ON EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS. D. WHERE MORE THAT ONE CARBON MONOXIDE ALARM IS REQUIRED TO BE INSTALLED WITHIN THE DWELLING UNIT OR WITHIN A SLEEPING UNIT THE ALARM SHALL BE INTERCONNECTED IN A MANNER THAT THE ACTIVATION OF ONE ALARM SHALL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. E. CRC MULTIPLE-PURPOSE ALARMS, CARBON MONOXIDE ALARMS COMBINED WITH SMOKE ALARMS SHALL COMPLY WITH ALL APPLICABLE STANDARDS, AND REQUIREMENTS FOR LISTING AND APPROVAL BY THE OFFICE OF THE STATE FIRE MARSHALL FOR SMOKE ALARMS. ALL ELECTRICAL OUTLETS SPECIFIED IN CEC SHALL BE TAMPER RESISTANT HIGH EFFICACY LUMINARIES OTHER THAN OUTDOOR HID: CONTAIN ONLY HIGH EFFICACY LAMPS AS OUTLINED IN TABLE 150-C, AND DO NOT CONTAIN A MEDIUM BASE SCREW SOCKET[E24/E26]. BALLASTS FOR LAMPS 13 WATTS OR GREATER ARE ELECTRIC AND HAVE OUTPUT FREQUENCY NO LESS THAN 20 kHz.. HIGH EFFICACY LUMINARIES - OUTDOOR HID: CONTAIN ONLY HIGH EFFICACY LAMPS AS OUTLINED IN TABLE 150-C, LUMINAIRE HAS FACTORY INSTALLED HID BALLAST. OCCUPANT SENSORS: SHALL COMPLY WITH SECTION 119[ D ] AND SHALL NOT TURN ON AUTOMATICALLY OR HAVE AN ALWAYS ON OPTION. LUMINAIRES THAT ARE RECESSED IN INSULATED CEILINGS ARE APPROVED FOR ZERO CLEARANCE INSULATION COVER [IC] AND ARE CERTIFIED TO ASTM E283 AND LABELED AS AIR TIGHT [ AT ] TO LESS THAN 2.O CFM AT 78 PASCALS AN INTERMITTENTLY OR CONTINUOUSLY OPERATING LOCAL MECHANICAL EXHAUST SYSTEM [ WITH OUTDOOR AIR] SHALL BE INSTALLED IN EACH KITCHEN AND BATHROOM COMPLYING WITH ASHRAE STANDARD 62.2-2007 AS ADOPTED BY THE CALIFORNIA ENERGY COMMISSION. INTERMITTENT LOCAL VENTILATION EXHAUST AIRFLOW RATES SHALL BE 50 CFM IN BATHROOMS AND 100 CFM IN KITCHENS. CONTINUOUS LOCAL VENTILATION EXHAUST AIRFLOW RATES SHALL BE 20 CFM IN BATHROOMS AND 5 ACH [AIR CHANGES/HOUR] IN KITCHENS BASED ON KITCHEN VOLUME. MANDATORY (CBEES 150.0(K) A) BATHROOMS: LIGHTING FIXTURES AND SWITCHES SHOWN ON FLOOR OR UTILITY PLANS SHALL DEMONSTRATE THE FOLLOWING: AT LEAST ONE HIGH-EFFICACY FIXTURE SHALL BE INSTALLED IN EACH BATHROOM. ALL OTHER BATHROOM LIGHTING SHALL BE HIGH EFFICACY OR CONTROLLED BY A VACANCY SENSOR. B) GARAGES, LAUNDRY ROOMS , AND UTILITY ROOMS: LIGHTING FIXTURES AND SWITCHES SHOWN ON FLOOR PR UTILITY PLANS SHALL DEMONSTRATE ALL LIGHTING IS HIGH EFFICACY AND CONTROLLED BY A VACANCY SENSOR C) ROOMS OTHER THAN KITCHENS, BATHROOMS, GARAGES, LAUNDRY ROOMS, OR UTILITY ROOMS: LIGHTING FIXTURES AND WITCHES SHOWN ON FLOOR OR UTILITY PLANS SHALL DEMONSTRATE ALL LIGHTING IS HIGH EFFICACY OR CONTROLLED BY EITHER A VACANCY SENSOR OR DINNER. D) OUTDOOR LIGHTING : LIGHTING FIXTURES AND SWITCHES SHOWN ON FLOOR OR UTILITY PLANS SHALL DEMONSTRATE ALL LIGHTING IS HIGH EFFICACY EXCEPTION : LOW-EFFICACY LIGHTING CONTROLLED BY A MOTION SENSOR AND EITHER A PHOTO CELL OR ASTRONOMICAL TIME CLOCK VACANCY SENSOR SWITCH TO BE USED IN GARAGES, SERVICE, AND LAUNDRYS. BRANCH CIRCUITS FOR ALL ROOMS (EXCEPT KITCHEN, BATHROOMS, & GARAGE) WILL BE ARC FAULT CIRCUIT PROTECT PER [CEC 210.12] ALL APPLIANCES TO HAVE SEPARATE DEDICATED CIRCUITS AND SIZED ACCORDING TO THE APPLIANCE SPECIFICATIONS SUCH AS , REFG., DISHWASHER, TRASH COMPACTOR, GARBAGE DISP., OVEN, RANGE, MICROWAVE, FAU., AIR COND., VAC., ECT. THE ELECTRICIAN TO CHECK WITH THE OWNER FOR THE PLACEMENT AND NUMBER OF TELEVISION, TELEPHONE, & INTERCOM OUTLETS. ELECTRICAL BOXES LOCATED IN FIRE RESISTIVE ASSEMBLIES MUST BE HORIZONTALLY SEPARATED BY NOT LESS THAN 24" ELECTRICAL BOXES LOCATED IN FIRE RESISTIVE ASSEMBLY MUST BE LISTED FOR THE RATING OF THE ASSEMBLY. ALL ELECTRICAL WORK TO BE DONE AS PER CEC. ALL GARAGE CIRCUITS TO TO BE NO LESS THAN 20 AMP. ALL BEDROOMS TO BE ON A MINIMUM OF TWO SEPARATE CIRCUITS WITH NO LESS THAN 20 AMP. EACH ALL BEDROOM BRANCH CIRCUITS WILL BE ARC FAULT CIRCUIT PROTECTED. PER CEC. ELECTRICIAN TO CHECK WITH THE OWNER FOR THE PLACEMENT AND THE NUMBER OF RECESSED CAN LIGHTS *SMOKE DETECTOR TO BE PERMANENTLY WIRED IN WITH A BATTERY BACKUP. SMOKE DETECTORS TO BE LOCATED CENTRALLY IN CORRIDOR OR AREA GIVING ACCESS TO SLEEPING ROOMS. WHEN SLEEPING ROOMS ARE UPSTAIRS, AT THE UPPER LEVEL IN CLOSE PROXIMITY TO THE STAIR. IN ROOMS ADJACENT TO HALLWAYS SERVING BEDROOMS, WHEN SUCH ROOMS HAVE A CEILING HEIGHT 24 INCHES OR MORE ABOVE THE CEILING HEIGHT IN THE HALLWAY. SMOKE DETECTORS SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREAS OF THE UNIT CBC 907.2.10.1.2 *BATHROOM RECEPTACLE OUTLETS SHALL BE SUPPLIED BY A MINIMUM OF ONE 20-AMPERE BRANCH CIRCUIT. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. THIS CIRCUIT MAY SERVE MORE THAN ONE BATHROOM *ELECTRICAL OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH CEC * ELECTRICAL OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH CEC. *LIGHTING OUTLETS CONTROLLED BY A WALL SWITCH SHALL BE PROVIDED IN ACCORDANCE WITH NEC. *LIGHTING FIXTURES INSTALLED IN CLOTHES CLOSETS SHALL COMPLY WITH CEC. * ALL BATHROOMS AND KITCHENS TO HAVE FLUORESCENT [40 LUMENS PER WATT] GENERAL LIGHTING PER CEC, * CONVENIENCE OUTLETS IN BATHROOMS, KITCHEN COUNTER TOPS, OUTDOORS,AND IN GARAGES AND BASEMENTS [ OTHER THAN FOR LAUNDRY AND SIMILAR EQUIPMENT] SHALL BE GFIC PROTECTED., ART. 210-8 *ELECTRICAL OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH CEC 210-8 ALL WIRING SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE. ALL APPLIANCES TO BE INSTALLED AS PER MANUFACTURES SPECS. TELEVISION, PHONE & TELEPHONE OUTLETS IN EVERY ROOM CHECK WITH OWNER FOR PLACEMENT * ALL BATHROOMS AND KITCHENS TO HAVE FLUORESCENT [40 LUMENS PER WATTOR GREATER] GENERAL LIGHTING PER CEC, TITLE 24 FIXTURES MUST BE OF THE BALLASTED TYPE THAT CAN ONLY ACCEPT FLUORESCENT BULBS. 110V SMOKE DET. PERMANENTLY WIRED IN W / BATT. BACK UP & CARBON MONOXIDE ALARM INSTALLED IN ALL BEDROOMS AND CENTRALLY LOCATED IN THE HALL. ONLY NEW ELECTRIAL SHOWN NEW ELECTRICAL PLAN SCALE 1/4" = 1'0" AFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCI GFCI GFCI GFCI GFCI GFCI S S F-S F-S F-S F-S F-S F-S F-SF-S F-SF-S F-SF-S F-SF-S 0SP F-S F-S WPGFCI FLOOR OUTLET SEE OWNER FOR PLACEMENT AFCI ALL GARAGE OUTLETS TO BE G.F.C.I. PROTECTED GAS METER ATTICACCESS22"X36"F-S GAS METER MOVE EXISTING 200 AMP. METER PANEL AND SERVICE ENTRANCE. NO CHANGE MOVE GAS METER AFCI 0SP GFCI GFCI WPGFCI 0SP WPGFCI EXH. FAN PROVIDING TEN AIR CHANGES PER HOUR DUCTLESS FANS ARE NOT ACCEPTABLE DISCHARGE POINT FOR EXHAUST AIR TO BE AT LEAST 3 FEET FROM ANY OPENING WHICH ALLOWS AIR ENTRY INTO OCCUPIED PORTIONS OF THE BUILDING NUTONE #ZN110HL DUCT AS PR MANUFACTURES SPEC. 110 CFM ENERGY STAR RATED ULTRA GREEN W/ HUMIDISTAT & MOTION SENSING SOUND RATING 0.3 SONES UL APPROVED FOR OVER TUBS OR SHOWERS 220V VS 0SP D-S GFCI AFCI F-S (SIZE)110V SMOKE DET. PERMANENTLY WIRED IN W / BATT. BACK UP & CARBON MONOXIDE ALARM OR WPGFCI S ELECTRICAL PLAN LEGEND 110V ELECTRIC OUTLETS FLOURESCENT SWITCH GROUND-FAULT CKT INTERRUPTER ARC FAULT CIRCUIT PROTECTED REC'D LIGHT FIXTURE FLOURESCENT W/ BALLASTS LIGHTS TO HAVE EFFICIENCY OF AT LEAST 40 LUMENS PER WATT LIGHT FIXTURE FLOURESCENT W/ BALLASTS LIGHTS TO HAVE EFFICIENCY OF AT LEAST 40 LUMENS PER WATT DIMMER SWITCH VACANCY SENSOR SWITCH OCCUPANT SENSOR SWITCH W/ PHOTO CONTROL WATERPROOF 110V ELECTRIC OUTLETS SWITCH DISCONNECT 2016 ENERGY LIGHTING STANDARDS KITCHEN BATHROOM GARAGE, LAUNDRY ROOM, UTILITY ROOM OUTDOOR LIGHTING ATTACHED TO BUILDINGS COMMON AREAS OF LOW RISE RESIDENTIAL BUILDINGS WITH 4 OR MORE DWELLING UNITS RESIDENTIAL PARKING LOTS AND GARAGES FOR 8 OR MORE VEHICLES HIGH EFFICACY OR OCCUPANCY SENSOR MUST MEET NONRESIDENTIAL LIGHTING STANDARDS LIGHTING FIXTURES AND SWITCHES SHOWN ON FLOOR OR UTILITY PLANS SHALL DEMONSTRATE ALL LIGHTING IS HIGH EFFICACY EXCEPTION : LOW-EFFICACY LIGHTING CONTROLLED BY A MOTION SENSOR AND EITHER A PHOTO CELL OR ASTRONOMICAL TIME CLOCK BATHROOMS: LIGHTING FIXTURES AND SWITCHES SHOWN ON FLOOR OR UTILITY PLANS SHALL DEMONSTRATE THE FOLLOWING: AT LEAST ONE HIGH-EFFICACY FIXTURE SHALL BE INSTALLED IN EACH BATHROOM. ALL OTHER BATHROOM LIGHTING SHALL BE HIGH EFFICACY OR CONTROLLED BY A VACANCY SENSOR. FIXTURES AND SWITCHES SHOWN ON FLOOR FOR UTILITY PLANS SHALL DEMONSTRATE ALL LIGHTING IS HIGH EFFICACY AND CONTROLLED BY A VACANCY SENSOR AT LEAST HALF THE INSTALLED WATTAGE OF LUMINARIES [ EXCEPT LIGHTING INTERNAL TO CABINETS] IN KITCHENS SHALL BE HIGH EFFICACY: LOW EFFICACY FIXTURES MUST BE SWITCHED SEPARATELY. LIGHTING INTERNAL TO CABINETS SHALL USE NO MORE THAN 20W OF POWER PER LINEAR FOOT OF ILLUMINATED CABINET. (760) 724-4159 DRAWING NUMBER SCALE: DATE: OWNERS NAME CONTRACTOR:DRAWN BY: APN. OF OWNERS PHONE# RONS HOUSE PLANS 8 AUTOMATIC IRRIGATION SYSTEMS CONTROLLERS INSTALLED AT THE TIME OF FINAL INSPECTION SHALL BE WEATHER-BASED( CGBSC 4.304.1) JOINTS AND OPENINGS, ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS, OR OTHER OPENINGS IN PLATES AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENING WITH CEMENT MORTAR, CONCRETE MASONRY OR SIMILAR METHOD ACCEPTABLE TO THE ENFORCING AGENCY (CGBSC 4.406.1) CAL GREEN APPLIES TO ALL NEW RESIDENTIAL OCCUPANCIES INCLUDING LOW RISE AND HIGH RISE BUILDINGS . IT ALSO APPLIES TO ALL RESIDENTIAL ALTERATIONS AND ADDITIONS WHERE THE ADDITIONS OR ALTERATION INCREASES THE BUILDING'S CONDITIONAL AREA VOLUME OR SIZE . THE REQUIREMENTS APPLY ONLY TO WITHIN THE SPECIFIC AREA OF THE ALTERATION OR ADDITION THE CALIFORNIA GREEN BUILDING CODE APPLIES TO ALL RESIDENTIAL BUILDING WHICH ARE UNDER THE JURISDICTION OF HCD: THE INCLUDES ALL BUILDING WITH AN OF THE FOLLOWING OCCUPANCIES : SINGLE FAMILY DWELLINGS, DUPLEXES, HOTELS, MOTELS, APARTMENTS, CONDOMINIUMS, RAW HOMES, ECT. ADHESIVES, SEALANTS AND CAULKS SHALL BE COMPLIANT WITH VOC AND OTHER TOXIC COMPOUND LIMITS (CGBS4.504.2.1) PAINTS,STAINS AND OTHER COATINGS SHALL BE COMPLIANT WITH VOC LIMITS (CGBSC 4.504.2) AEROSOL PAINTS AND COATING SHALL BE COMPLIANT WITH PRODUCT WEIGHTED MIR LIMITS OF VOC AND OTHER TOXIC COMPOUNDS' (CGBSC 4.504.2.3) DOCUMENTATION SHALL BE PROVIDED TO VERIFY THAT COMPLIANT VOC LIMIT FINISH MATERIALS HAVE BEEN USED. A LETTER FROM THE CONTRACTOR AND OR THE BUILDING OWNER CERTIFYING WHAT MATERIAL HAS BEEN USED AND ITS COMPLIANCE WITH THE CODE MUST BE SUBMITTED TO THE BUILDING INSPECTOR. ( CGBS 4.504.2.4) CARPET AND CARPET SYSTEMS SHALL BE COMPLIANT WITH VOC LIMITS. A LETTER FROM THE CONTRACTOR AND OR THE BUILDING OWNER CERTIFYING WHAT MATERIAL HAS BE USED AND ITS COMPLIANCE WITH THE CODE MUST BE SUBMITTED TO THE BUILDING INSPECTOR ( CGBSC 4.504.3 ) FIFTY PERCENT OF FLOOR AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH THE VOC EMISSIONS LIMITS DEFINED IN THE COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS ( CHPS) LOW-EMITTING MATERIALS LIST OR BE CERTIFIED AND THE RESILIENT FLOOR COVERING INSTITUTE (RCFI ) FLOOR SCORE PROGRAM CGBSC 4.504.4 DUCT OPENINGS AND OTHER RELATED AIR DISTRIBUTION OPENINGS ARE TO BE SEALED, AND MECHANICAL EQUIPMENT IS TO BE COVERED, DURING CONSTRUCTION ENDS OF ALL CGC 4.504.1 MINIMUM OF 65% OF CONSTRUCTION WASTE GENERATED AT THE SITE IS DIVERTED TO RECYCLED OR SALVAGE PER. CGC 4.408.1 BEFORE FINAL INSPECTION A COMPLETE OPERATION AND MAINTENANCE MANUAL SHALL BE PROVIDED TO BUILDING OCCUPANT OR OWNER . CONTRACTOR OR OWNER SHALL SUBMIT AN AFFIDAVIT THAT CONFIRMS THE DELIVERY OF MAINTENANCE MANUAL (CGBSC4.410.1) GLAZING FRAMES MADE OF VINYL MATERIALS SHALL HAVE WELDED CORNERS, METAL REINFORCEMENT IN THE INTERLOCK AREA, AND BE CERTIFIED TO THE MOST CURRENT EDITION OF ANSI/AAMA/NWWDA 101/I.S.2 STRUCTURAL REQUIREMENTS (CRC R327.8.2.1.1) "PER 2013 SGBSC SEC 4.303.2 PLUMBING FIXTURES (WATER CLOSETS AND URINALS) AND FITTING ( FAUCETS AND SHOWERHEADS) SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA PLUMBING CODE ( CPC ) AND TABLE 1401.1 OF THE CPC. " PROVIDE ULTRA LOW FLUSH TOILETS ALL PLUMBING FIXTURES AND FITTINGS WILL BE WATER CONSERVING AND WILL COMPLY WITH THE 2013 CGBSC SEC.4.303.1 THE PLUMBING FIXTURES AND PLUMBING FITTINGS SHALL MEET THE STANDARDS NOTED BELOW TO MEET THE CAL GREEN 20% INDOOR WATER SAVINGS: 1] WATER CLOSET, GRAVITY TANK-TYPE, FLUSHOMETER TANK TYPE, ELECTROMECHANICAL HYDRAULIC TYPE = 1.28 GALLONS PER FLUSH MAX. 2] SHOWER HEAD = 2.0 GPM MAX. 3] KITCHEN FAUCETS = 1.8 GPM MAX. 4]LAVATORY FAUCETS= 1.5 GPM MAX. 5] URINALS .5 GALLONS PER FLUSH ] IN SHOWERS AND TUB-SHOWER COMBINATIONS, CONTROL VALVES MUST BE PRESSURE BALANCED OR THERMOSTATIC MIXING VALVES. CPC 6]PERMANENT VACUUM BREAKERS SHALL BE INSTALLED WITH ALL NEW HOSE BIBS. THE PLUMBING FIXTURES AND PLUMBING FITTINGS SHALL MEET THE STANDARDS NOTED BELOW TO MEET THE CAL GREEN 20% INDOOR WATER SAVINGS: 1] WATER CLOSET, GRAVITY TANK-TYPE, FLUSHOMETER TANK TYPE, ELECTROMECHANICAL HYDRAULIC TYPE = 1.28 GALLONS PER FLUSH MAX. 2] SHOWER HEAD = 2.0 GPM MAX. 3] KITCHEN FAUCETS = 1.8 GPM MAX. 4]LAVATORY FAUCETS= 1.5 GPM MAX. 5] URINALS .5 GALLONS PER FLUSH ] IN SHOWERS AND TUB-SHOWER COMBINATIONS, CONTROL VALVES MUST BE PRESSURE BALANCED OR THERMOSTATIC MIXING VALVES. CPC 6]PERMANENT VACUUM BREAKERS SHALL BE INSTALLED WITH ALL NEW HOSE BIBS. PARTICLEBOARD, MEDIUM DENSITY FIBERBOARD (MDF ), AND HARDWOOD PLYWOOD USED IN INTERIOR FINISH SYSTEMS SHALL COMPLY WITH LOW FORMALDEHYDE EMISSION STANDARDS. A LETTER FROM THE FROM THE INSTALLER AND OR THE BUILDING OWNER CERTIFIED WHAT MATERIAL HAS BEEN USED AND DOCUMENTING ITS COMPLIANCE WITH THE CODE MUST BE SUBMITTED TO THE BUILDING INSPECTOR (CGBSC4.504.5) BUILDING MATERIALS WITH VISIBLE SIGNS OF WATER DAMAGE SHALL NOT BE INSTALLED. WALLS AND FLOORS FRAMING SHALL NOT BE ENCLOSED WHEN FRAMING MEMBERS EXCEED 19% MOISTURE CONTENT B] MOISTURE CONTENT OF BUILDING MATERIALS USED IN WALLS AND FLOOR FRAMING IS TO BE CHECKED FOR THE MINIMUM REQUIREMENTS BEFORE ENCLOSURE. MOISTURE CONTENT SHALL BE VERIFIED BY EITHER A PROBE TYPE OR CONTACT TYPE MOISTURE METER. A CERTIFICATE OF COMPLIANCE INDICATION DATE OF TEST LOCATION AND RESULTS ISSUED BY A THE FRAMER SUBCONTRACTOR OR GENERAL CONTRACTOR MUST BE SUBMITTED TO THE BUILDING INSPECTOR (CGBSC 4.505.3) "PER 2013 GREEN CODE SEC 4.506.1 MECHANICAL EXHAUST FANS WHICH EXHAUST DIRECTLY FROM BATHROOMS SHALL COMPLY WITH THE FOLLOWING: 1. FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE OUTSIDE THE BUILDING. 2. UNLESS FUNCTIONING AS COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM. FANS MUST BE CONTROLLED BY A HUMIDISTAT WHICH SHALL BE READILY ACCESSIBLE . HUMIDISTAT CONTROLS SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANG OF 50 TO 80%." A MECHANICAL EXHAUST SYSTEM SUPPLY SYSTEM, OR COMBINATION THEREOF SHALL BE INSTALLED FOR EACH DWELLING UNIT TO PROVIDE WHOLE-BUILDING VENTILATION WITH OUTDOOR AIR COMPLYING WITH ASHRAE STANDARD 62.2-2007 AS ADOPTED BY THE CALIFORNIA ENERGY COMMISSION. I.A.Q. WHOLE-BUILDING VENTILATION CALCULATION ASHRAE 62.2 EQ. 4.1a: Qfan = 0.01 x 900 + 7.5(4+1) = 46.5 CFM PER TABLE 5.1: INTERMITTENT LOCAL VENTILATION EXHAUST, PROVIDE 68 CFM MINIMUM FAN LOCATION: HALL FAN MODEL TYPE: AIR KING MODEL AK80LS-1 ENERGY STAR 80 CFM @ 1.0 SONES DUCT TYPE: 4" DIAMETER SMOOTH WALL G.S. DUCT. LOCATE IN ATTIC THRU ROOF TO OUTSIDE AIR. MAXIMUM ALLOWABLE DUCT LENGTH 35 FEET. (PER ASHRAE 62.2 TABLE 7.1) CONTROL: STANDARD ON/OFF SWITCH LABELED TO COMMUNICATE FUNCTION. CONTROL NOTE: A LABEL OR SIGN IS REQUIRED AT THE CONTROLLER OR SWITCH TO INFORM THE OCCUPANT THAT THE FAN IS A WHOLE HOUSE VENTILATION FAN THAT SHOULD OPERATE WHENEVER THE HOME IS OCCUPIED. AN INTERMITTENTLY OR CONTINUOUSLY OPERATING LOCAL MECHANICAL EXHAUST SYSTEM (WITH OUTDOOR AIR) SHALL BE INSTALLED IN EACH KITCHEN AND BATHROOM COMPLYING WITH ASHRAE STANDARD 62.2-2007 AS ADOPTED BY THE CALIFORNIA ENERGY COMMISSION. INTERMITTENT LOCAL VENTILATION EXHAUST AIRFLOW RATES SHALL BE 50 CFM IN BATHROOMS AND 100 CFM IN KITCHENS. CONTINUOUS LOCAL VENTILATION EXHAUST AIRFLOW RATES SHALL BE 20 CFM IN BATHROOMS AND 5 ACH (AIR CHANGES/HOUR) IN KITCHENS BASED ON KITCHEN VOLUME. 1/4"=1'0"RTL 11 CONTRACTOR SHALL CHECK ALL DIMENSIONS, AND NOTIFY ENGINEER OF ANY DISCREPENCIES PRIOR TO STARTING CONSTRUCTIONB 29 THE OWNER AGREES TO THE AFORE MENTIONED CONDITIONS BY ACCEPTING THESE PLANS AND AGREES TO FURNISH NEW OWNER WITH A COPY NOTES 14 PROVIDE ATTIC VENTAREA MORE THAN 1/150TH OF THE ATTIC AREA. AS PER C.B.C.. 25 ALL CONCRETE AND STUCCO WILL CRACK, THE CONTRACTOR SHALL TAKE PRECAUTIONS TO LIMIT THIS CRACKING. 30 THIS HOUSE SHALL CONFORM TO THE STATE OF CALIF. ENERGY COMMISSIONS TITLE 24 REGULATIONS. 28 ALL NAILS SHALL BE COMMON WIRE AND SHALL BE PER CBC. 27 ALL NAILING AND NAILING CONNECTIONS SHALL CONFORM TO THE CBC 26 ALL FRAMING TO BE DONE IS A GOOD WORKMAN LIKE MANNER AND TO CONFORM TO THE CBC. 24 ALL MECHANICAL WORK SHALL BE DONE IN A GOOD WORKMAN LIKE MANNER AND CONFORM TO CMC 23 ALL PLUMBING WORK SHALL BE DONE IN A GOOD WORKMAN LIKE MANNER AND CONFORM TO THE CPC 22 ALL ELECTRICAL WORK SHALL BE DONE IN A GOOD WORKMAN LIKE MANNER AND CONFORM TO THE CEC 21 RON IS A DRAFTSMAN WHO IS WORKING FOR YOU AS YOUR EMPLOYEE. YOU THE EMPLOYER TO PROVIDE ALL INSURANCE'S FOR THIS JOB 20 ALL ROOFING TO BE WATERPROOF AND INSTALLED AS PER MANUFACTURES SPECIFICATIONS AND DONE IN A GOOD WORKMAN LIKE MANNER. 19 REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 40. ALL BOLTS SHALL COMPLY WITH ASTM A-307 18 CERAMIC TILE TO BE SET IN FULL BED OF MORTAR ON 15# FELT OR BETTER. CONTRACTOR TO TAKE PRECAUTIONS TO MINIMIZE CRACKING. PRECAUTIONS SHALL BE TAKEN TO MAXIMIZE WATERPROOFING. ALL WORK TO BE DONE IN A GOOD WORKMAN LIKE MANNER. 15 BRACE RIDGE AND PURLINS ,HIPS, AND VALLEYS TO INTERIOR BEARING WALLS @6'0" O.C.MIN. U.N.O. 16 SEE SIMPSON CATALOGUE FOR CORRECT CONNECTOR AND NUMBER AND PLACEMENT PRIOR TO ORDERING. 13 ALL BEDROOMS TO HAVE AT LEAST ONE WINDOW WITH A MAX. SILL HEIGHT OF 42" AND WITH A OPENABLE AREA OF NOT LESS THAN 5.7 SQ. FT. , 24" NET CLEAR OPENING HEIGHT, 20" NET CLEAR OPENING WIDTH. C.B.C. 12 DRY WALL, LATH & PLASTER , STUCCO CONTRACTORS TO TAKE PRECAUTIONS TO MINIMIZE CRACKING. PRECAUTIONS SHALL BE TAKEN TO MAXIMIZE WATERPROOFING. ALL WORK SHALL COMPLY WITH THE CB.C 10 WALL BRACING IN EVERY STUD WALL WITH 1X6 LET IN BRACES AT NO MORE THAN 60 DEG. NOR LESS THAN 45 DEG. FROM HORIZONTAL, OR PLYWOOD SHEAR PANEL BRACE, FROM EACH CORNER AND EVERY 25' OF LINEAL WALL. 9 ALL STUD WALLS TO HAVE A DOUBLE TOP PLATES WITH A MIN. 48" LONG LAP SPLICES. 8 CUTTING, NOTCHING AND DRILLING OF STUD WALLS SHALL COMPLY WITH THE C.B.C. . 7 EVERY OPENING IN ANY EXTERIOR WALL SHALL BE FLASHED WITH SHEET METAL AND OR WATERPROOF BUILDING PAPER. 6 ALL CRIPPLE WALLS 14" OR LESS IN HEIGHT SHALL BE SOLID BLOCKED. 5 ALL FRAMING LUMBER TO BE D.F.#2 OR BETTER ,AND USE D.F.S.S. FOR BEAM 6" OR LARGER 4 MAXIMUM BRACED HEIGHT FOR STUDS OF NON-BEARING WALLS IS AS FOLLOWS: 2X4&3X4 IS 14', 2X5 IS 16',AND 2X6 IS 20' 3 MAXIMUM UNBRACED HEIGHT FOR 2X4,3X4,2X5,2X6 STUDS IS 10' FOR BEARING WALLS 1 DIMENSIONS HAVE PREFERENCE TO SCALE. 2 BALLOON FRAME ALL WALLS OF ROOMS WITH SLOPING CEILINGS. 1/2" CLEAR BETWEEN TRUSSES AND NON-BEARING PARTITIONS. 17 DRAFTSMANS RESPONSIBILITY IS LIMITED ONLY TO ASSISTING THROUGH PLAN CHECK. OWNER TO CHECK WITH STRUCTURAL ENGINEER FOR LATERAL & VERTICAL ANALYSIS AND THE STRUCTURAL INTEGRITY, ECT. PRIOR TO CONSTRUCTION. DRAFTSMANS MAXIMUM LIABILITY SHALL NOT BE GREATER THAN THE COST OF THE PLANS TABLE FASTENING SCHEDULE2013 CALIFORNIA BUILDING CODE CONNECTION 1. Joist to sill or girder FASTENING LOCATIONa,m 3-8d common [2-1/2"x.0 131"] 3- 3"x 0.131" nails 3- 3" 14gage staples 2-16d common [3-1/2"x0.162"] toenail 2. BRIDGING TO JOIST 2-8d common [2-1/2"x 0.131"] 2- 3"x 0.131" nails 2- 3" 14guage staples toenail each end 3. 1"x6" subfloor or less to each joist 2-8d common [2-1/2"x.0.131"]face nail 4. wider than 1"x6" subfloor each joist 3-8d common [2-1/2"x 0.131"]face nail 5. 2" subfloor to joist or girder blind and face nail 6. sole plate to joist or blocking sole plate to joist or blocking at braced wall panel 16d common [3-1/2"x0.162"] at 16" o.c. 3"x 0.131" nails at 8" o.c. 3" 14 gage staples at 12"o.c. 3"=16d common [3-1/2"x0.162"] at 16" o.c. 4-3"x 0.131" nails at 16" 4-3" 14 gage staples per 16" typical face nail braced wall panels 7. top plate to stud 2-16d common [3-1/2"x0.162"] 3- 3"x 0.131" nails 3- 3" 14gage staples end nailed 8. stud to sole plate end nailed4-8d common [2-1/2"x.0 131"] 4- 3"x 0.131" 4- 3"x.14gage staple 2-16d common [3-1/2"x0.162"] 3- 3"x 0.131" nails 3- 3" 14gage staples end nailed 9. double studs 16d common [3-1/2"x0.135"] at 24" o.c. 3"x 0.131" nails at 8" o.c. 3" 14 gage staples at 8"o.c. face nail 10. double top plates double top plates 16d common [3-1/2"x0.135"] at 16" o.c. 3"x 0.131" nails at 12" o.c. 3"x14 gage staples at 12"o.c. [8]16d common [3-1/2"x0.162"] [12] 3"x 0.131" nails [12] 3" 14 gage staples typical face nail lap splice 11. blocking between joist or rafters to top plate 3-8d common [2-1/2"x.0 131"] 3- 3"x 0.131" nails 3- 3" 14gage staples toe nail 12.rim joist to top plate 8d common [2-1/2"x.0 131"] at 6" o.c. 3"x 0.131" at 6" o.c. 3" 14gage staple at 6" o.c. toe nail 13. top plates, laps and intersections 2-16d common [3-1/2"x0.162"] 3- 3"x 0.131" nails 3- 3" 14gage staples face nail 14. continuous header, two pieces 16d common [3-1/2"x0.162"]16" o.c. along edge 15. ceiling joists to plate 3-8d common [2-1/2"x.0 131"] 5- 3"x 0.131" nails 5- 3" 14gage staples toe nail 16. continuous header to stud 4-8d common [2-1/2"x.0 131"]toe nail 17. ceiling joists, laps over partitions [see section 2308.10.4.1, table 2308.10.4.1] 3-16d common [3-1/2"x0.162"]minimum table 2308.10.4.1 4- 3"x 0.131" nails 4- 3" 14gage staples face nail 18. ceiling joists parallel rafters [see section 2308.10.4.1, table 2308.10.4.1] 3-16d common [3-1/2"x0.162"]minimum table 2308.10.4.1 4- 3"x 0.131" nails 4- 3" 14gage staples face nail 19. rafter to plate [see section 2308.10.4.1, table 2308.10.4.1] 3-8d common [2-1/2"x.0 131"] 3- 3"x 0.131" nails 3- 3" 14gage staples toe nail 20. 1" diagonal brace to each stud and plate 2-8d common [2-1/2"x.0 131"] 2- 3"x 0.131" nails 3- 3" 14gage staples face nail 21. 1"x8" sheathing to each bearing 3-8d common [2-1/2"x.0 131"]face nail 22. wider than 1"x8" sheathing to each bearing 3-8d common [2-1/2"x.0 131"]face nail 23. built-up corner studs 16d common [3-1/2"x0.162"] 3"x 0.131" nails 3" 14gage staples 24" o.c.16" o.c.16" o.c. 24. built-up girder and beams 20d common [4"x0.192"] 32" o.c. 3"x 0.131" nails at 24"o.c. 3" 14gage staples at 24"o.c. 2-20d common [4"x0.192"] 3-3"x 0.131" nails at 24"o.c. 3-3" 14gage staples at 24"o.c. face nail at top and bottom staggered on opposite sides face nail atends and at each splice 25. 2" planks 16d common [3-1/2"x0.162"]at each bearing 26. collar tie to rafter 3-10d common [3"x0.148"] 4-3"x 0.131" nails at 24"o.c. 4-3" 14gage staples at 24"o.c. face nail 27. jack rafter to hip 3-10d common [3"x0.148"] 4-3"x 0.131" nails at 24"o.c. 4-3" 14gage staples at 24"o.c. 2-16d common [3"x0.162"] 3-3"x 0.131" nails at 24"o.c. 3-3" 14gage staples at 24"o.c.face nail toe nail 28.roof rafter to 2-by ridge beam 2-16d common [3"x0.162"] 3-3"x 0.131" nails at 24"o.c. 3-3" 14gage staples at 24"o.c. 2-16d common [3"x0.162"] 3-3"x 0.131" nails at 24"o.c. 3-3" 14gage staples at 24"o.c. toe nail face nail 29. joist to band joist 3-16d common [3"x0.162"] 4-3"x 0.131" nails at 24"o.c. 4-3" 14gage staples at 24"o.c. face nail 30. ledger strip 3-16d common [3"x0.162"] 4-3"x 0.131" nails at 24"o.c. 4-3" 14gage staples at 24"o.c. face nail 31. wood structural panels and particleboard subfloor, roof and wall sheathing [ to framing] b c,l n o ed p c d d e c d d 1/2" and less 6d 2-3/8"x0.113" 1-3/4" 16 gage 19/32" to 3/4" 8d or 6d 2-3/8"x0.113" 2" 16 gage 7/8" to 1" 8d 1-1/8" to 1-1/4" 10d or 8d 3/4" and less 6d 7/8" to 1" 8d 1-1/8" to 1-1/4" 10d or 8d p single floor [combination subloor-underlayment to framing] 32. panel siding [ to framing]1/2" and less 6d 5/8" 8d f f 33. fiberboard sheating g 1/2" no. 11 gage roofing nail 6d common nail [2"x0.113"] no. 16 gage staple 25/32" no. 11 gage roofing nail 6d common nail [2"x0.113"] no. 16 gage staple h i h i 34. interior paneling 1/4" 4d 3/8" 6d j k For SI: 1 inch = 25.4 mm. a. Common or box nails are permitted to be used except where otherwise stated. b. Nails spaced at 6 inches on center at edges, 12 inches at intermediate supports except 6 inches at supports where span are 48 inches or more. For nailing of wood structural panel and particleboard diaphragms and shear walls, refer to Section 2305. Nails for wall sheathing are permitted to be common, box or casing. c. Common or deformed shank (6d - 2 x 0.113" ; 8d - 21/2 x 0.131" ; 10d - 3 x0.148" ). d. Common (6d - 2 x 0.113" ; 8d - 21/2 x 0.131" ; 10d - 3 x 0.148" ). e. Deformed shank (6d - 2 x 0.113" ; 8d - 21/2 x 0.131" ; 10d - 3 x 0.148" ). f. Corrosion-resistant siding (6d x 17/8" 0.106 ; 8d x 23/8" 0.128 ") or casing (6d - 2 x 0.099" ; 8d - 21/2 x 0.113" ) nail. g. Fasteners spaced 3 inches on center at exterior edges and 6 inches on center at intermediate supports, when used as structural sheathing. Spacing shall be 6 inches on center on the edges and 12 inches on center at intermediate supports for nonstructural applications. h. Corrosion-resistant roofing nails with 7/16-inch-diameter head and 11/2-inch length for 1/2-inch sheathing and 1 3/4-inch length for 25/32-inch sheathing. i. Corrosion-resistant staples with nominal 7/16-inch crown and 1 1/8-inch length for 1/2-inch sheathing and 1 1/2-inch length for 25/32-inch sheathing. Panel supports at 16 inches (20 inches if strength axis in the long direction of the panel, unless otherwise marked). j. Casing (11/2 x 0.080" ) or finish (11/2 x 0.072" ) nails spaced 6 inches on panel edges, 12 inches at intermediate supports. k. Panel supports at 24 inches. Casing or finish nails spaced 6 inches on panel edges, 12 inches at intermediate supports. l. For roof sheathing applications, 8d nails (21/2 x 0.113" ) are the minimum required for wood structural panels. m.Staples shall have a minimum crown width of 7/16 inch. n. For roof sheathing applications, fasteners spaced 4 inches on center at edges, 8 inches at intermediate supports. o. Fasteners spaced 4 inches on center at edges, 8 inches at intermediate supports for subfloor andwall sheathing and 3 inches on center at edges, 6 inches at intermediate supports for roof sheathing. p. Fasteners spaced 4 inches on center at edges, 8 inches at intermediate supports. EXH. FAN PROVIDING TEN AIR CHANGES PER HOUR DUCTLESS FANS ARE NOT ACCEPTABLE DISCHARGE POINT FOR EXHAUST AIR TO BE AT LEAST 3 FEET FROM ANY OPENING WHICH ALLOWS AIR ENTRY INTO OCCUPIED PORTIONS OF THE BUILDING NUTONE #ZN110HL 6" DUCT 110 CFM ENERGY STAR RATED ULTRA GREEN W/ HUMIDISTAT & MOTION SENSING SOUND RATING 0.3 SONES UL APPROVED FOR OVER TUBS OR SHOWERS EXHAUST FANS WHICH TERMINATE OUTSIDE THE BUILDING ARE PROVIDED IN EVERY BATHROOM THAT CONTAINS A SHOWER OR TUB UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM FAN MUST BE CONTROLLED BY A HUMIDISTAT WHICH CAN ADJUST BETWEEN 50 TO 80 PERCENT A GENERAL NOTES 8 14 SEER Condenser   Minimum Requirement    ***New 13 SEER condensers can no longer be installed in California under any condition.*** On June 27, 2011 the U.S. Department of Energy adopted new federal air conditioner efficiency standards. For California those federal standards require efficiencies of SEER 14 and EER 12.2 for central split system air conditioners smaller than 45,000 Btu/hr (a SEER 14 and EER of 11.7 is required for larger central split system air conditioners). The new federal standards went into effect on January 1, 2015, which was six months after the July 1, 2014 effective date of the 2013 Standards. Although new federal efficiency standards went into effect on January 1, 2015, initially under the 2013 Building Energy Efficiency Standards, 13 SEER A/C condensers could still be installed if the manufacturing date of that appliance was prior to 1 January 2015. As of September 21, 2015, code language in the 2013 Residential Compliance Manual was revised to indicate that equipment "installed on or after January 1st, 2015, must comply with the minimum SEER and EER requirements of (Table 4-6) regardless of date of manufacture." Per direction from the CEC, the CalCERTS registry will not allow entry of SEER/EER values that do not meet the minimum federal standards. Please confirm that all of your installers are aware of this change as it may still be possible to acquire 13 SEER appliances from HVAC suppliers or from internal company inventory. A copy of the 2013 Residential Compliance Manual may be downloaded from the CEC at this URL: http://www.energy.ca.gov/title24/2013standards/residential_manual.html   4.3.1 Mandatory Measures for Cooling Equipment GREEN BUILDING CODE REQUIREMENTS NOTES POLLUTANT CONTROL: DURING CONSTRUCTION, ENDS OF DUCT OPENINGS ARE TO BE SEALED, AND MECHANICAL EQUIPMENT IS TO BE COVERED. CGC 4.504.1 NOTE ON THE PLANS THAT PRIOR TO FINAL INSPECTION THE LICENSED CONTRACTOR, ARCHITECT OR ENGINEER IN RESPONSIBLE CHARGE OF THE OVERALL CONSTRUCTION MUST PROVIDE TO THE BUILDING DEPARTMENT OFFICIAL WRITTEN VERIFICATION THAT ALL APPLICABLE PROVISIONS FROM THE GREEN BUILDING STANDARDS CODE HAVE BEEN IMPLEMENTED AS PART OF THE CONSTRUCTION. CGC 102.3. SEE ROOF PLAN A35 @24" O.C. 2X FREEZE BLOCKS 2X FASCIA DBL 2X TOP PLATES SEE FOUNDATION PLAN SEE ELEVATIONS 5./8" DRYWALL 1/2" DRYWALL R-13 INSULATION FOR 4" WALL AND R-21 INSULATION FOR 6" WALLS R-30 INSULATION B E.N.8d @6"0.C. SEE FLOOR PLAN FOR HEIGHT 2X PRESSURE TREATED MUD SILL 2X FIRE BLOCKS BETWEEN ALL STUDS AND STAGGERED 2 X 4 U.N.O. STUDS @ 16" O.C. (760) 415-3660DANIELLE ALLEN RTL12-27-16