Loading...
HomeMy WebLinkAbout2018-02-07; Planning Commission; ; CDP 2017-0037 (DEV2017-0122) – WEST RESIDENCE The City of Carlsbad Planning Division A REPORT TO THE PLANNING COMMISSION Single Family Coastal Development Permit Item No. Application complete date: November 28, 2017 P.C. AGENDA OF: February 7, 2018 Project Planner: Greg Fisher Project Engineer: David Rick SUBJECT: CDP 2017-0037 (DEV2017-0122) – WEST RESIDENCE – Request for approval of a Coastal Development Permit to allow for the addition of 2,160 square feet of habitable space with 670 square feet of decks and porches, and a 240 square foot garage addition to an existing single-family residence within the Mello II Segment of the city’s Local Coastal Program located at 4225 Clearview Drive within Local Facilities Management Zone 1. The project site is not within the appealable area of the California Coastal Commission. The City Planner has determined that the project belongs to a class of projects that the State Secretary for Resources has found do not have a significant impact on the environment, and it is therefore categorically exempt from the requirement for the preparation of environmental documents pursuant to Section 15301(e), additions to an existing structure, of the state CEQA Guidelines. I. RECOMMENDATION That the Planning Commission ADOPT Planning Commission Resolution No. 7287 APPROVING Coastal Development Permit CDP 2017-0037 based upon the findings and subject to the conditions contained therein. II. PROJECT DESCRIPTION AND BACKGROUND Project Site/Setting: The 0.47 acre (20,473 square feet) project site is located at 4225 Clearview Drive between Macarthur Avenue and Hillside Drive as shown on the attached location map. The relatively flat lot sits slightly below street grade and is developed with a one-story residence and attached two-car garage. The neighborhood is characterized by one- and two-story single-family residences, with two-car garages. The proposed project, an addition to a single-family residence, is a common occurrence in this neighborhood. Table “A” below includes the General Plan designations, zoning and current land uses of the project site and surrounding properties. TABLE A Location General Plan Designation Zoning Current Land Use Site R-4-Residential R-1-15000 Single-family residence North R-4-Residential R-1-15000 Single-family residence South R-4-Residential R-1-15000 Single-family residence East R-4-Residential R-1-15000 Single-family residence West R-4-Residential R-1-15000 Single-family residence Proposed Residential Construction: The project consists of an addition of 2,160 square feet of new habitable space to the existing 1,750 square foot residence. After demolition/removal of 542 square feet of existing habitable space, the residence with have a total of 3,368 square feet of habitable space. Other 2 CDP 2017-0037 (DEV2017-0122) – WEST RESIDENCE February 7, 2018 Page 2 additions include 670 square feet of decks and porches and 240 square feet of new garage area. The architectural style is coastal contemporary and exterior finishes include medium grey hardiplank, light grey stucco and rock veneer siding. The roof consists of a decorative dark grey composition shingle material. Proposed Grading: Estimated grading quantities include 0 cubic yards (cy) of cut, and 0 cy of fill. A grading permit will not be required for this project. III. ANALYSIS The project is subject to the following regulations and requirements: A. R-4 Residential General Plan Land Use Designation; B. One-Family Residential (R-1-15000) Zone (CMC Section 21.10); C. Coastal Development Regulations for the Mello II Segment of the Local Coastal Program (CMC Chapter 21.201) and Chapter 21.203 (Coastal Resource Protection Overlay Zone); D. Inclusionary Housing Ordinance (CMC Chapter 21.85); and E. Growth Management (CMC Chapter 21.90). The recommendation for approval of this project was developed by analyzing the project’s consistency with the applicable city regulations and policies. The project’s compliance with each of the above regulations is discussed in detail in the sections below. A. General Plan Land Use Designation The project site has a General Plan Land Use designation of R-4 Residential, which allows for the development of single-family residences at a density of 0-4 dwelling units per acre (du/ac) with a Growth Management Control Point (GMCP) of 3.2 du/ac. The project site has a net area of 0.47 acres and at the GMCP, one dwelling unit is allowed. Therefore, the project complies with the R-4 General Plan Land Use Designation. B. R-1 Residential Zone (CMC Section 21.10) The project is required to comply with all applicable regulations and development standards of the Carlsbad Municipal Code (CMC) including the One-Family Residential (R-1) zone. The proposed project meets or exceeds all applicable requirements of the R-1-15000 zone (Shown in Table B below). TABLE B – R-1-15,000 ZONE DEVELOPMENT STANDARDS Standard Required/Allowed Proposed Front Yard Setback 20’ 44’ Side Yard Setback 10’ 15’ Rear Yard Setback 20’ 48’ Max Building Height 30’ with >3:12 roof pitch 28’ 6” Lot Coverage 40 percent maximum 13 percent Parking Two-car garage (20’ X 20’) Three-car garage CDP 2017-0037 (DEV2017-0122) – WEST RESIDENCE February 7, 2018 Page 3 C. Conformance with the Coastal Development Regulations for the Mello II Segment of the Local Coastal Program (CMC Chapter 21.201) and the Coastal Resource Protection Overlay Zone (CMC Chapter 21.203) The project site is located within the Mello II Segment of the Local Coastal Program (LCP) and is not within the appeals jurisdiction. The site is also located within and subject to the Coastal Resource Protection Overlay Zone. The project’s compliance with each of these programs and ordinances is discussed below: 1. Mello II Segment of the Certified Local Coastal Program and all applicable policies The subject site has an LCP Land Use Plan designation of R-4 Residential, which allows for a density of 0-4 dwelling units per acre (du/ac) and 3.2 du/ac at the Growth Management Control Point (GMCP). The project site has a net area of 0.47 acres and at the GMCP, one dwelling unit is allowed. Therefore, the project is consistent with the R-4 LCP Land Use Plan designation. The project consists of an addition of 2,160 square feet of new habitable space to the existing residence, removal of 542 square feet of original habitable space, the addition of 670 square feet of decks and porches, and a 240 square foot addition to the existing garage. The project is compatible with the surrounding development of one- and two-story single-family residences. The additions, including a second floor to the existing one-story residence, will not obstruct views of the coastline as seen from public lands or the public right-of-way, or otherwise damage the visual beauty of the coastal zone. No agricultural uses currently exist on the previously developed site, nor are there any sensitive resources located on the developable portion of the site. The existing single-family residence is not located in an area of known geologic instability or flood hazard. Since the site does not have frontage along the coastline, no public opportunities for coastal shoreline access are available from the subject site. Furthermore, the residentially designated site is not suited for water-oriented recreation activities. 2. Coastal Resource Protection Overlay Zone The project is consistent with the provisions of the Coastal Resource Protection Overlay Zone (CMC Chapter 21.203 of the Zoning Ordinance) in that the project will adhere to the city’s Master Drainage Plan, Grading Ordinance, Storm Water Ordinance, BMP Design Manual and Jurisdictional Runoff Management Program (JRMP) to avoid increased urban run-off, pollutants and soil erosion. The subject property does not include steep slopes (equal to or greater than 25 percent gradient) or native vegetation. D. Inclusionary Housing Ordinance (CMC Chapter 21.85) Pursuant to CMC Section 21.85.030.D.1, a project may be exempt from the inclusionary housing requirement if an existing residence is altered, improved, restored, repaired, expanded, or extended, provided that the number of units is not increased. Since there will not be an increase in the number of units on the property, the project is exempt from the inclusionary housing requirement. E. Growth Management The proposed project is located within Local Facilities Management Zone 1 in the northwest quadrant of the city. No impacts are associated with the project as the project consists of a remodel and addition to an existing residence and no new impacts will be generated. CDP 2017-0037 (DEV2017-0122) – WEST RESIDENCE February 7, 2018 Page 4 IV. ENVIRONMENTAL REVIEW This project is exempt from CEQA per the exemptions listed below: (1) Section 15301(e) of CEQA (Class 1) exempts additions to an existing structure. A Notice of Exemption will be filed by the City Planner upon project approval. ATTACHMENTS: 1. Planning Commission Resolution No. 7287 2. Location Map 3. Disclosure Statement 4. Reduced Exhibits 5. Exhibit(s) “A” – “I” dated February 7, 2018 SKYLINE RDSUNNYHILL DRCLEARVIEW DRHILLSIDE DR MAC ARTHU R A V CDP 2017-0037 West Residence SITE MAP SITE E L C AMINO RE A LLA COSTA AV A L G A R DCARLSBAD B L ATTACHMENT 2 PLPLPLPLPLPLPLPLPLPLPL PL PL PL PL PL PL PL PL PL PL PLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPL N86° 56' 20"W 141.42 FT N09° 13' 11"E138.80 FTN86° 56' 19"W 156.31 FT N03° 03' 41"E138.00 FTSMHPPWM207-085-08-00 207-085-09-00 207-085-07-00 207-085-02-00 207-085-03-00 SHED EXISTING LANDSCAPEEXISTING CONCRETE DRIVEWAYEXISTING HOUSE GARAGE SHED (TO BE REMOVED) FENCE FENCE FENCE14.00'SIDE SETBACK14.00'SIDE SETBACK20.00'FRONT SETBACK 30.00' 20.00'FRONT SETBACK 30.00' SD-5 SD-5 SD-5 W E S N EXISTING DECK 224 ft224 ft224 ft2 2 4 f t226 ft226 f t 226 ft228 ft228 ft228 f t 230 ft230 ft230 f t 2 3 0 f t 232 ft232 ft232 ft232 ft234 ft234 f t234 ft234 ft236 ft236 ft236 f t 236 ft236 f t 238 ft238 ft238 ft2 3 8 f t 2 3 8 f t 240 ft240 ft240 ft28.00'REAR SETBACK 40.00' EXISTING SITE PLAN PARCEL #:207-085-08-00 4225 CLEARVIEW DR, CARLSBAD, CA 92008 AREA:20,500.00 sqft (0.47 acres) VICINITY MAP 0 SCALE=1":10' 10 20 40 50 ft5 0 1"2"4"5"12"14" 30 3" WEST RESIDENCE 1"=10'SCALE: 09-28-17DATE: OWNERS NAME: MIKE WEST OWNER BUILDER CONTRACTOR:DRAWN BY: APN:207-085-08 OWNERS PHONE: 760 518-6571 (760) 724-4159 DRAWING NUMBER SP1 OF 26 EXISTING LIVING AREA REMOVED= 542.33' NEW HOUSE AREA=2160.25' NEW DECK/PORCHES=240.00' NEW GARAGE=240.00' EXISTING GARAGE=400.00' EXISTING REMAINING HOUSE=1208.17' EXISTING PORCHES & DECKS=158.92 ADT= 10 (NO NET INCREASE) WATER DEMAND= NO NET INCREASE SCOPE OF WORK: REMODEL EXISTING HOUSE REMOVE 542.33 SQ.FT. BUILD NEW ADDITION OF 2160.25 WITH 670.0 SQ.FT. OF DECKS AND PORCHES AND A 240.00 SQ.FT. GARAGE ADDITION AND ALL THE WORK ASSOCIATED WITH ACCOMPLISHING THESE ASKS. CUT: FILL: IMPORT: EXPORT: REMEDIAL: CY EARTHWORK QUANTITIES CY CY CY 6 6 0 0 NO SOILS REPORT AVAILABLE NEW GARAGE = 240 SF NEW ADDITION - CRAWL SPACE OWNER: MIKE WEST PHONE# 760-518-6571 ADDRESS & SITE ADDRESS: 4225 CLEARVIEW DR CARLBARD, CA 92008 APN: 207-085-08 SITE PLAN DRAWN BY: RON'S HOUSE PLANS RON LINVILLE 760) 724-4159 TOPOGRAPHIC MAPPING BY: CIREMELE SURVEYING CHRISTOPHER D CIREMELE LICENSED CALIFORNIA SURVEYOR #5267 PLPLPLPLPLPLPLPLPLPLPL PL PL PL PL PL PL PL PL PL PL PLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPL N86° 56' 20"W 141.42 FT N09° 13' 11"E138.80 FTN86° 56' 19"W 156.31 FT N03° 03' 41"E138.00 FTSMHPPWM207-085-08-00 207-085-09-00 207-085-07-00 207-085-02-00 207-085-03-00 SHED EXISTING LANDSCAPEEXISTING CONCRETE DRIVEWAYEXISTING HOUSE GARAGE SHED (TO BE REMOVED) FENCE FENCE FENCE14.00'SIDE SETBACK14.00'SIDE SETBACK20.00'FRONT SETBACK 30.00' 20.00'FRONT SETBACK 30.00' SD-5 SD-5 SD-5 NEW ADDITION NEW GARAGE NEW ADDITION W E S N NEW DECK EXISTING DECK 224 ft224 ft224 ft2 2 4 f t226 ft226 f t 226 ft228 ft228 ft228 f t 230 ft230 ft230 f t 2 3 0 f t 232 ft232 ft232 ft232 ft234 ft234 f t234 ft234 ft236 ft236 ft236 f t 236 ft236 f t 238 ft238 ft238 ft2 3 8 f t 2 3 8 f t 240 ft240 ft240 ft28.00'REAR SETBACK 40.00' PROPOSED SITE PLAN PARCEL #:207-085-08-00 4225 CLEARVIEW DR, CARLSBAD, CA 92008 AREA:20,500.00 sqft (0.47 acres) VICINITY MAP 0 SCALE=1":10' 10 20 40 50 ft5 0 1"2"4"5"12"14" 30 3" EXISTING LIVING AREA REMOVED= 542.33' NEW HOUSE AREA=2160.25' NEW DECK/PORCHES=240.00' NEW GARAGE=240.00' EXISTING GARAGE=400.00' EXISTING REMAINING HOUSE=1208.17' EXISTING PORCHES & DECKS=158.92 ADT= 10 (NO NET INCREASE) WATER DEMAND= NO NET INCREASE SCOPE OF WORK: REMODEL EXISTING HOUSE REMOVE 542.33 SQ.FT. BUILD NEW ADDITION OF 2160.25 WITH 670.0 SQ.FT. OF DECKS AND PORCHES AND A 240.00 SQ.FT. GARAGE ADDITION AND ALL THE WORK ASSOCIATED WITH ACCOMPLISHING THESE ASKS. CUT: FILL: IMPORT: EXPORT: REMEDIAL: CY EARTHWORK QUANTITIES CY CY CY 6 6 0 0 NO SOILS REPORT AVAILABLE NEW GARAGE = 240 SF NEW ADDITION - CRAWL SPACE OWNER: MIKE WEST PHONE# 760-518-6571 ADDRESS & SITE ADDRESS: 4225 CLEARVIEW DR CARLBARD, CA 92008 APN: 207-085-08 WEST RESIDENCE 1"=10'SCALE: 09-28-17DATE: OWNERS NAME: MIKE WEST OWNER BUILDER CONTRACTOR:DRAWN BY: APN:207-085-08 OWNERS PHONE: 760 518-6571 (760) 724-4159 DRAWING NUMBER SP2 OF 26 SITE PLAN DRAWN BY: RON'S HOUSE PLANS RON LINVILLE 760) 724-4159 TOPOGRAPHIC MAPPING BY: CIREMELE SURVEYING CHRISTOPHER D CIREMELE LICENSED CALIFORNIA SURVEYOR #5267 SAN MARCOS, CALIFORNIA 920692121 MONTIEL ROADOF SHEET NO.FAX: (760) 480-7477PHONE: (760) 839-7302REVISIONJOB NO.:DATE:SCALE:DESCRIPTION:NO.175813-59-6-2017NOTEDDATECARLSBAD, CA 920084225 CLEARVIEW DRIVEWEST RESIDENCENo. 65122 Exp. 09/30/2017 APN #: 207-085-08BMP PLANFeet 0 10 20 (760) 724-4159 DRAWING NUMBER SCALE: DATE: OWNERS NAME CONTRACTOR:DRAWN BY: APN. OF OWNERS PHONE# RONS HOUSE PLANS 1 5A 1/4"=1'0"RTL FRONT VIEW SCALE 1/4"=1'0" 10-31-16 (760) 518-6571MIIKE WEST #2778 8' 14'10" 14' 18'6" 28'6" 7' 8' 6'8" GENERAL NOTES 1. DIMENSIONS DERIVED FROM PREVIOUS PLANS PROVIDED BY THE OWNER. 2. FIELD VERIFY DIMENSIONS PRIOR TO ENGINEERING, CONSTRUCTION & SUBMITTING FOR PERMITS. 3. BUILDING PERMIT SUBMITTAL & APPROVAL REQUIRED PRIOR TO ANY MODIFICATION OR CONSTRUCTION WHICH IS REQUIRED TO MEET CURRENT BUILDING CODES & REGULATIONS IN THE ZONED AREA OF SUBJECT PROPERTY NEWEXISTING NEW EXISTING NEWEXISTING +OR- OHAGIN ROOF VENTS 95 SQ. IN. EACH= .65 SQ. FT. ICC#9650A = OHAGIN ROOF VENTS 95 SQ. IN. EACH= .65 SQ. FT. ICC#9650A = DECORATION LIKE VENT SCOPE OF WORK: REMODEL EXISTING HOUSE REMOVE 542.33 SQ.FT. BUILD NEW ADDITION OF 2160.25 WITH 670.0 SQ.FT. OF DECKS AND PORCHES AND A 240 SQ.FT. GARAGE ADDITION AND ALL THE WORK ASSOCIATED WITH ACCOMPLISHING THESE TASKS THIS PROJECT WILL COMPLY WITH THE COUNTY OF SAN DIEGO LIGHTING ORDINANCE OWNER : MIKE WEST PHONE # : (760) 518-6571 ADDRESS & SITE ADDRESS : 4225 CLEARVIEW DR. CARLSBAD, CA 92008 THIS PROJECT WILL COMPLY WITH THE FOLLOWING BUILDING CODES AND ASSOCIATED CITY AMENDMENTS: 2016 CALIFORNIA RESIDENTIAL CODE AND OR 2016 CALIFORNIA BUILDING CODE AS APPLICABLE 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE 2016 CALIFORNIA ELECTRICAL CODE 2016 CALIFORNIA PLUMBING CODE 2016 CALIFORNIA FIRE CODE 2016 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS EXISTING LIVING AREA REMOVED =_________542.33'____________ NEW HOUSE AREA LIVING AREA=_________2160.25'____________ NEW DECKS PORCHES =____670.0'_________ NEW GARAGE=_____240.0'____________ EXISTING GARAGE=_____400.0'____________ EXISTING REMAINING HOUSE =_____1208.17'____________ EXISTING PORCHES & DECKS=_____158.92'____________ _________________________ * PLANS BY RON LINVILLE 804 PIER VIEW WY SUITE 207 OCEANSIDE, CA. 92054 *ALL WORK SHALL COMPLY WITH ALL CURRENT CODES AS ADAPOTED BY THE COUNTY AND STATE OCCUPANCY= FOR HOUSE R-3, FOR THE GARAGE U TYPE OF CONSTRUCTION= V-B #2652-2778 MED. GREY HARDIPLANK TO BE INSTALLED AS PER MANUFACTURES SPECIFICATIONS TWO LAYERS OF GRADE D PAPER SHALL BE APPLIED OVER ALL WOOD BASE SHEATHING. MED. GREY HARDIPLANK TO BE INSTALLED AS PER MANUFACTURES SPECIFICATIONS TWO LAYERS OF GRADE D PAPER SHALL BE APPLIED OVER ALL WOOD BASE SHEATHING. WHITE FASCIA LT. GREY 7/8" STUCCO WITH METAL LATH OVER 15# FELT MIN. AS PER WITH A DRIP SCREED 2" BELOW THE MUD SILL AND A MINIMUM OF 8 INCHES ABOVE GRADE AND 2" ABOVE PAVEMENT SEE OWNER FOR TYPE AND COLOR, TEXTURE, ECT. GRADE D PAPER SHALL BE USED UNDER ALL EXTERIOR WALL COVERINGS AND TWO LAYERS OF GRADE D PAPER SHALL BE APPLIED OVER ALL WOOD BASE SHEATHING. WHITE TRIM WHITE TRIM WHITE DOORS WHITE DOORS HARDIPLANK TO BE INSTALLED AS PER MANUFACTURES SPECIFICATIONS TWO LAYERS OF GRADE D PAPER SHALL BE APPLIED OVER ALL WOOD BASE SHEATHING. MED. GREY 30' 30' MAX HEIGHT EXISTING AND FINISHED GRADE ROOFING SHALL HAVE A MINIMUM CLASS "A" RATING ROOF COVERING: ELK PREMIUM ROOFING FIBERGLASS SHINGLES OVER 1LAYER 15# FELT ICBO #ESR-1475 INSTALLED AS PER MANUFACTURES SPECIFICATIONS TIMBERLINE COOL SERIES - BARKWOOD INITIAL SOLARREFLECTANCE = 0.27 THERMAL EMITTANCE = 0.92 SOLAR REFLECTANCE INDEX (SRI) = 29 LEED® CREDITS =YES CRRC # 0676-0041 DARK GREY ROOF VENTS TO MATCH ROOF COLOR BROWN TONES ELDRADO STONE I.C.C. ERS #1215 INSTALLED AS PER MANUFACTURES SPECIFICATIONS ROCK VENEER: ROOFING SHALL HAVE A MINIMUM CLASS "A" RATING ROOF COVERING: ELK PREMIUM ROOFING FIBERGLASS SHINGLES OVER 1LAYER 15# FELT ICBO #ESR-1475 INSTALLED AS PER MANUFACTURES SPECIFICATIONS TIMBERLINE COOL SERIES - BARKWOOD INITIAL SOLARREFLECTANCE = 0.27 THERMAL EMITTANCE = 0.92 SOLAR REFLECTANCE INDEX (SRI) = 29 LEED® CREDITS =YES CRRC # 0676-0041 DARK GREY (760) 724-4159 DRAWING NUMBER SCALE: DATE: OWNERS NAME CONTRACTOR:DRAWN BY: APN. OF OWNERS PHONE# RONS HOUSE PLANS 2 5A 1/4"=1'0" 10-31-16 (760) 518-6571MIIKE WEST RTL #2778 GENERAL NOTES 1. DIMENSIONS DERIVED FROM PREVIOUS PLANS PROVIDED BY THE OWNER. 2. FIELD VERIFY DIMENSIONS PRIOR TO ENGINEERING, CONSTRUCTION & SUBMITTING FOR PERMITS. 3. BUILDING PERMIT SUBMITTAL & APPROVAL REQUIRED PRIOR TO ANY MODIFICATION OR CONSTRUCTION WHICH IS REQUIRED TO MEET CURRENT BUILDING CODES & REGULATIONS IN THE ZONED AREA OF SUBJECT PROPERTY 8' 14'10" 14' 18'6" 28'6" 6'8" 8' 6'8" 8' ADJUST OVERHANG AS NEEDED THIS AREA 2'2" NEW EXISTING NEWEXISTINGNEW +OR- 10'10'3/4" EXISTING 6'8" 8' NEW 9'9'3/4" 28'6" +OR- EXISTINGNEW EXISTING DECK NEW DECK 8' 14' 6'8" 8' 2'2" NEW 9'9'3/4" 10'10'3/4" 28'6" +OR- NEW REAR VIEW SCALE 1/4"=1'0" RIGHT SIDE SCALE 1/4"=1'0"LEFT SIDE SCALE 1/4"=1'0" ELEVATION PLAN LEGEND STUCCO [ SEE OWNER FOR COLOR & TEXTURE ] SIDING [ SEE OWNER FOR COLOR & TEXTURE ] OR OR OR OR SHADED AREA BRICK OR ROCK VENEER ROOF COVERING SEE PLAN TILE [ SEE OWNER FOR COLOR] SHUTTERS SEE OWNER WINDOWS SEE PLAN LT. GREY 7/8" STUCCO WITH METAL LATH OVER 15# FELT MIN. AS PER WITH A DRIP SCREED 2" BELOW THE MUD SILL AND A MINIMUM OF 8 INCHES ABOVE GRADE AND 2" ABOVE PAVEMENT SEE OWNER FOR TYPE AND COLOR, TEXTURE, ECT. GRADE D PAPER SHALL BE USED UNDER ALL EXTERIOR WALL COVERINGS AND TWO LAYERS OF GRADE D PAPER SHALL BE APPLIED OVER ALL WOOD BASE SHEATHING. SKYLIGHTS SHALL BE TEMPERED GLASS. ATTIC VENTILATION SHALL NOT BE PERMITTED IN SOFFITS, RAKES, OR EAVE OVERHANGS. GUTTERS AND DOWN SPOUTS SHALL BE CONSTRUCTED ON NON-COMBUSTIBLE MATERIAL, AND DESIGNED TO REDUCE ACCUMULATION OF LEAF LITTER AND DEBRIS. DETAIL THE PROPOSED GUTTERS AND DOWN SPOUTS. [ NO GUTTERS AND DOWN SPOUTS USED. IF GUTTERS USED THE GUTTER COMPANY TO PROVIDE DETAILS. ] EXTERIOR DOORS SHALL BE APPROVED IGNITION RESISTANT CONSTRUCTION, SOLID-CORE WOOD NOT LESS THAN 1-3/4" THICK, OR HAVE A FIRE PROTECTION RATING OF NOT LESS THAN 20 MINUTES. PROJECTIONS SUCH AS DECKS, CARPORTS, BALCONIES, PATIO COVERS, ETC. SHALL BE OF NON- COMBUSTIBLE CONSTRUCTION, FIRE-RETARDANT TREATED WOOD, HEAVY TIMBER CONSTRUCTION, OR ONE-HOUR FIRE-RESISTIVE CONSTRUCTION. THE FIRST FIVE FEET OF FENCES AND OTHER ITEMS ATTACHED TO A STRUCTURE SHALL BE CONSTRUCTED OF NON-COMBUSTIBLE MATERIAL OR MEET THE SAME FIRE-RESISTIVE STANDARDS AS THE EXTERIOR WALLS OF THE STRUCTURE. GARAGE DOORS TO BE METAL. ROOF COVERINGS WHERE THE PROFILE ALLOWS A SPACE BETWEEN THE ROOF COVERING AND ROOF DECKING. THE SPACE AT EAVE ENDS SHALL BE FIRE STOPPED TO PRECLUDE ENTRY OF FLAMES OR EMBERS. [ USE NON-COMBUSTIBLE BIRD STOP FOR CURVED TILE ] OTHERWISE CONSTRUCTED TO PREVENT INTRUSION OF FLAMES AND EMBERS. EXTERIOR WALL SURFACES MUST BE NON-COMBUSTIBLE [ STUCCO, MASONRY, CEMENT FIBER BOARD, ETC. ]. PLYWOOD OR 3/4" DROP SIDING MAY BE USED WITH AN UNDERLAY OF 1/2 INCH FIRE RATED GYPSUM BOARD. UNDER FLOOR AREAS SHALL BE ENCLOSED TO THE GROUND WITH THE SAME EXTERIOR WALL CONSTRUCTION COMBUSTIBLE EAVES, SOFFITS . FASCIA'S SHALL BE CONSTRUCTED AS REQUIRED IN GUIDANCE DOCUMENT DPLU#198 [ STUCCO ALL EAVES] ALL VENTS [ ROOF, FOUNDATION, COMBUSTION AIR, ETC. ] MUST BE LOUVERED AND COVERED WITH 1/8" NON-COMBUSTIBLE, CORROSION-RESISTANT METAL MESH. TURBINE VENTS SHALL TURN IN ONE DIRECTION ONLY. PAPER FACED INSULATION IS NOT PERMITTED IN ATTICS OR OTHER VENTILATED SPACES. EXTERIOR WINDOWS, WINDOW WALLS, GLAZED DOORS. AND GLAZED OPENING WITHIN DOORS SHALL BE DUAL-GLAZED UNITS WITH A MINIMUM OF ONE TEMPERED PANE, OR SHALL BE GLASS BLOCK UNITS OR, SHALL HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN 20 MINUTES. GLAZING FRAMES MADE OF VINYL SHALL HAVE WELDED CORNERS AND METAL REINFORCEMENT IN THE INTERLOCK AREA. PROVIDE NOTE ON ELEVATION SHEET AND WINDOW SCHEDULE. SPECIFY FRAME MATERIAL AND AN APPROVED MANUFACTURE OR PROVIDE MANUFACTURES INFO DOCUMENTING COMPLIANCE. OHAGIN ROOF VENTS 95 SQ. IN. EACH= .65 SQ. FT. ICC#9650A = Note on the plans: "Attic ventilation openings shall be covered with corrosion-resistant metal mesh with 1/16” minimum to .” maximum openings. Section R806.1. ALL VENTS CAN BE SUBSTITUTED WITH A DIFFERENT STYLE OF VENT WITH THE SAME VENTING AREA ALL ATTIC VENTILATION OPENING SHALL BE COVERED WITH CORROSION-RESISTANT METAL MESH WITH MESH OPENING OF 1/16 INCH IN EACH DIMENSION TOTAL REQUIRED= TOTAL PROVIDED = NEW ROOF VENTS: VENTS PROVIDED VENTS REQUIRED NEW HOUSE AREA ÷ 150= QUNT. TYPE AREA NEW GARAGE AREA ÷ 150= 14"X12"VENT[.94'EA.]= 14-1/2"X24" VENTS [2.13'] = 14-1/2"X30" VENTS [3.02'] = 14 "X36" VENTS (3.2') = OHAGIN ROOF VENTS 95 SQ. IN. EACH= .65 SQ. FT. ICC#9650A = ONLY NEW VENTS SHOWN. ANY VENTS REMOVED MUST BE REPLACED BY NEW VENTS OF EQUAL OR GRATER SIZE 240 '1.6' 1411.5'9.41' 11.01' 20 13.0' OHAGIN ROOF VENTS 95 SQ. IN. EACH= .65 SQ. FT. ICC#9650A = 13.0' 5 :12 PITCH 3 :12 PITCH 3 :12 PITCH5 :12 PITCH 4X6 R.R. @24" O.C. W/ 2X6 T&G ON TOP @ PORCH 4X6 R.R. @24" O.C. W/ 2X6 T&G ON TOP @ PORCH LT. GREY 7/8" STUCCO WITH METAL LATH OVER 15# FELT MIN. AS PER WITH A DRIP SCREED 2" BELOW THE MUD SILL AND A MINIMUM OF 8 INCHES ABOVE GRADE AND 2" ABOVE PAVEMENT SEE OWNER FOR TYPE AND COLOR, TEXTURE, ECT. GRADE D PAPER SHALL BE USED UNDER ALL EXTERIOR WALL COVERINGS AND TWO LAYERS OF GRADE D PAPER SHALL BE APPLIED OVER ALL WOOD BASE SHEATHING. WHITE TRIM WHITE DECK WHITE DECKWHITE DOOR WHITE FASCIA WHITE FASCIA WHITE DECK WHITE FASCIA WHITE FASCIA WHITE TRIM WHITE FASCIA WHITE DECK WHITE DECKWHITE DECK WHITE DOOR30' MAX HEIGHT 30' 30' 30' MAX HEIGHT 30' 30' MAX HEIGHT EXISTING AND FINISHED GRADE EXISTING AND FINISHED GRADE EXISTING AND FINISHED GRADE ROOFING SHALL HAVE A MINIMUM CLASS "A" RATING ROOF COVERING: ELK PREMIUM ROOFING FIBERGLASS SHINGLES OVER 1LAYER 15# FELT ICBO #ESR-1475 INSTALLED AS PER MANUFACTURES SPECIFICATIONS TIMBERLINE COOL SERIES - BARKWOOD INITIAL SOLARREFLECTANCE = 0.27 THERMAL EMITTANCE = 0.92 SOLAR REFLECTANCE INDEX (SRI) = 29 LEED® CREDITS =YES CRRC # 0676-0041 DARK GREY 5 :12 PITCH 5 :12 PITCH 5 :12 PITCH 3 :12 PITCH 5 :12 PITCH ROOF VENTS TO MATCH ROOF COLORROOF VENTS TO MATCH ROOF COLOR ROOF VENTS TO MATCH ROOF COLOR BROWN TONES ELDRADO STONE I.C.C. ERS #1215 INSTALLED AS PER MANUFACTURES SPECIFICATIONS ROCK VENEER: (760) 724-4159 DRAWING NUMBER SCALE: DATE: OWNERS NAME CONTRACTOR:DRAWN BY: APN. OF OWNERS PHONE# RONS HOUSE PLANS 2A 1/4"=1'0" 10-31-16 (760) 518-6571MIIKE WEST RTL EXISTING DECK DN 18" UP 18 RISERS UP 4 RISERS DN 1 RISER REMOVE KITCHEN AND NON BEARING WALLS DN 4 RISERS REMOVE DOOR DN 18" #2778 NEW WALL NEW WALL 6" WALL 6" WALL 5A DN 18 RISERS NEW DECK BASE CAB OVER ANGLED FLOOR ROOF PLAN SCALE 1/4" =1'0" PITCH 12 5 ENG. TRUSSES @ 24" O.C. FAU IN ATTIC ATTICACCESS22"X36"ENG. TRUSSES @ 24" O.C. SLOPE DECK 1/4" TO 12" DECK COVERING: DECK TREX® PER MANUF. SPECS. ICC# ESR-1190 ROOF NOTES: ROOF PITCH 5:12 TYPICAL NO ROOF TOP MECHANICAL EQUIPMENT NO ROOF TOP STAIRWAYS NO ROOF TOP APPURTENANCES ( NO ROOF TOP EQUIPMENT RIDGE RIDGE RIDGE RIDGE RIDGE RIDGE RIDGE VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY SLOPESLOPE SLOPE SLOPESLOPE SLOPESLOPE SLOPE SLOPE SLOPE SLOPE SLOPE SLOPE SLOPE SLOPESLOPE 542.33 ft2 (760) 724-4159 DRAWING NUMBER SCALE: DATE: OWNERS NAME CONTRACTOR:DRAWN BY: APN. OF OWNERS PHONE# RONS HOUSE PLANS 3 1/4"=1'0" 10-31-16 (760) 518-6571MIIKE WEST RTL 41'10" 2'6" 13'2" 14'9" 3'11'9" 3' 6'8" 21'5" 16'1" 5'9" 5'2" 14'9" 2 6 2 0 21'6"24'7"20' 22' 80'10" 3 0 EXISTING 8'0"X5'0" EXISTING 5'0"X4'0" EXISTING 6'0"X4'0" EXISTING 5'0"X3'0" EXISTING 2'6"X3'6" SH EXISTING 5'0"X3'0" EXISTING 2'0"X2'0" EXISTING 10'0"X6'8" 3' EXISTING MASTER SUITE EXISTING BEDROOM#2 EXISTING LIVING ROOM EXISTING GARAGE EXISTING ENTRY 28 3'7" 16'5" WINDOW, SLIDING, GLASS DOOR OR MIRROR DOOR NEW FULL HEIGHT WALLS EXISTING FULL HEIGHT WALLS SHELF AND POLE HANDRAIL OR PARTIAL WALL HEADER OR WALL OPENINGS RETAINING WALLS FLOOR PLAN LEGEND EXISTING FLOOR PLAN SCALE 1/4" = 1'0" 440.00 ft 2 8.92 ft 2 8'3"+OR- CEILING VAULTED CEILING VAULTED CEILING 1750.50 ft 2 14'10"24'7"20' 80'10" 26 5'0"X2'6" TUB & SHOWER 2'6" 4'1" 13'5" 11'6"10' EXISTING 5'0"X4'0" FAU 10'6" 5'5'0"X2'6"TUB &SHOWER20 2 6 EXISTING 2'0"X1'0" 10'8" BR#3/DEN VAULTED CEILING VAULTED CEILING VAULTED CEILING EXISTING 5'0"X3'6" DW REFG.RANGEEXISTING FAMILY ROOM EXISTING KITCHEN VAULTED CEILING VAULTED CEILINGWASHERDRYER26 TANKLESS WATER HEATER ABOVE 3'7" 5' 26 LINEN 9'4" 20' 3'0" OPENING 4'8" 3'4" WH EXISTING 2'6"X3'6" SH 3 0 10' 15' EXISTING DECK DN 18" 26 EXISTING HOUSE LIVING AREA=_____________________ EXISTING PORCHES =_____________ EXISTING GARAGE=_________________ 2'2' DN 18" 25'9" 16'1" 25'9" #2778 53'10"53'10" GENERAL NOTES 1. DIMENSIONS DERIVED FROM PREVIOUS PLANS PROVIDED BY THE OWNER. 2. FIELD VERIFY DIMENSIONS PRIOR TO ENGINEERING, CONSTRUCTION & SUBMITTING FOR PERMITS. 3. BUILDING PERMIT SUBMITTAL & APPROVAL REQUIRED PRIOR TO ANY MODIFICATION OR CONSTRUCTION WHICH IS REQUIRED TO MEET CURRENT BUILDING CODES & REGULATIONS IN THE ZONED AREA OF SUBJECT PROPERTY AREA TO BE REMOVED LESS REMOVED AREA ADJUSTED EXISTING HOUSE AREA 1208.17'= 5A EXISTING HOUSE LIVING AREA=_____________________ EXISTING DECK & PORCHES =_____________ EXISTING GARAGE=_________________ NEW GARAGE=_________________ NEW 1ST FLOOR AREA_______________ NEW PORCHES___________________ NEW DECK_____________________ 1296.50 ft2 35.00 ft2 1750.50 ft 2 (760) 724-4159 DRAWING NUMBER SCALE: DATE: OWNERS NAME CONTRACTOR:DRAWN BY: APN. OF OWNERS PHONE# RONS HOUSE PLANS 4 1/4"=1'0" 10-31-16 (760) 518-6571MIIKE WEST RTL 41'10" 2'6" 13'2" 14'9" 3'11'9" 3' 6'8" 21'5" 16'1" 5'2" 14'9" 2 6 2 0 21'6"24'7"20' 80'10" NEW 8'0"X5'0" NEW 5'0"X4'0" SL EXISTING 2'6"X3'6" SH EXISTING 5'0"X3'0" EXISTING 2'0"X2'0" EXISTING MASTER SUITE EXISTING GARAGE 3'7" 16'5" WINDOW, SLIDING, GLASS DOOR OR MIRROR DOOR NEW FULL HEIGHT WALLS EXISTING FULL HEIGHT WALLS SHELF AND POLE HANDRAIL OR PARTIAL WALL HEADER OR WALL OPENINGS RETAINING WALLS FLOOR PLAN LEGEND 400.00 ft 2 8.92 ft 2 8'3"+OR- CEILING 14'10"24'7"20' 80'10" 26 5'0"X2'6" TUB & SHOWER 2'6" 13'5" 11'6"10' NEW 5'0"X4'0" SL 10'6" 5' EXISTING 6'0"X3'6" 10'8" VAULTED CEILING REMOVE EXISTING 5'0"X3'6" NEW BEDROOM VAULTED CEILINGWASHERDRYER TANKLESS WATER HEATER ABOVE 3'7" 3' 9'4" 20' FILL IN 3'0" OPENING 4'8" 3'4" WH EXISTING 2'6"X3'6" SH 3 0 10' 15' EXISTING DECK DN 18" NEW 1ST FLOOR PLAN SCALE 1/4" = 1'0" 5' 22' 8' 16'6" 12' 22' NEW GARAGE 8'3"+OR- CEILING 2'8'2' 20' 3" STEEL PIPE FILLED WITH CONC. 36" ABOVE SLAB & 24" DEEP 16'0"X7'0" SECTIONAL STEEL DOOR 8'0"X7'0" SECTIONAL STEEL DOOR NEW 10'0"X8'0" NEW GREAT ROOM NEW KITCHEN 4' 4' PANTRY 2 4 STORAGE UNDER STAIRS UP 18 RISERS 2 6 3 0 3 0 NEW ENTRY15' 7' 17'7" UP 4 RISERS NEW PORCH 26 DN 1 RISER NEW MEDIA ROOM 26 2'6" 12'6" NEW BEDROOM VAULTED CEILING 26 2 6 5' 3'6"4' 5'0"X6'8" MIRROR DOOR 5'0"X6'8" MIRROR DOOR2828 7'6"6'6" 2 8 2 8 REMOVE KITCHEN AND NON BEARING WALLS 2' NEW NEW 5'0"X2'6"TUB &SHOWER3' 26SINK NEW 2'0"X3'0" SH DN 4 RISERS DN 4 RISERS REMOVE DOOR 28 NEW DINING ROOM DW4' SUB- ZERO 4'6" 5' 12' 10' 4' 3'6" 35'6" 19' 4' NEW 10'0"X8'0" 5'NEW DECK 240.00 ft2 336.00 ft2 15.00 ft2+ 3 0 4' NEW 2'0"X5'0" SH NEW 2'0"X5'0" SH 10'3/4" CEILING 10'3"+OR- CEILING 10'3/4" CEILING 10'3/4" CEILING 11'6" + OR - CEILING 2' 6' ++2.00 ft2 63.00 ft2 DN 18" 25'9"25'9" 16'1" 2'3'2' NEW 1'0"X5'0" NEW 1'0"X5'0" NEW TOP 6'0"X2'0" #2778 EXISTING 5'0"X3'0"5'0"X2'6"TUB &SHOWEREXISTING 2'0"X1'0" BR#3/DEN VAULTED CEILING 2 6 LINEN 2 0 EXISTING BEDROOM#2 VAULTED CEILING 53'10"53'10" 52' 1'10" 92'10" 12' DN 4 RISERS GENERAL NOTES 1. DIMENSIONS DERIVED FROM PREVIOUS PLANS PROVIDED BY THE OWNER. 2. FIELD VERIFY DIMENSIONS PRIOR TO ENGINEERING, CONSTRUCTION & SUBMITTING FOR PERMITS. 3. BUILDING PERMIT SUBMITTAL & APPROVAL REQUIRED PRIOR TO ANY MODIFICATION OR CONSTRUCTION WHICH IS REQUIRED TO MEET CURRENT BUILDING CODES & REGULATIONS IN THE ZONED AREA OF SUBJECT PROPERTY NEW WALL 2X6 NEW WALL 3'3"3'3"2'6"2'6" 4'9-1/2"4'9-1/2"8' 2'16'2' 10'4'10'6'6" 9"3"3' 9" 3' 6'6" 2'6" NEW WALL 17'9"17'9" 542.33 ft2LESS REMOVED AREA = ADJUSTED EXISTING HOUSE AREA 1208.17' =1361.5' =50.0' 2 6 COMP. TO BE PLACED AT OWNERS APPROVAL NOT TO BE IN THE BUILDING SETBACKS COMP. TO BE PLACED AT OWNERS APPROVAL NOT TO BE IN THE BUILDING SETBACKS WH TANKLESS WATER HEATER ATTIC ACCESS 22"X36" FAU IN ATTIC MOVE WINDOW AS NEEDED TRASH DRAWER NEW 3'0"X5'0" FIXED NEW 3'0"X5'0" FIXED 5'9" 3'2" 150.00 ft2+=158.92' 5A K 8 K 8 N 8 M 8 O 8 A 7 G 11 F 11 FOR EGRESS DOORS: MAX . 7.75 INCHES FOR IN-SWINGING DOORS FROM TOP OF THRESHOLD TO LANDING AND 1.5 INCHES FOR OUT-SWINGING FOR NON-REQUIRED DOORS: IN OR OUT SWINGING 7.75 INCHES LANDINGS AT DOORS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF DOOR AND LENGTH IN THE DIRECTION OF TRAVEL OF NOT LESS THAN 36", WILL BE PROVIDED ON EACH SIDE OF DOORS. THE ELEVATION OF LANDING SHALL NOT EXCEED ONE INCH DIFFERENCE THAN THE THRESHOLD OF THE DOORWAY[ 8" IF DOOR DOES NOT SWING OVERT THE LANDING]. ALL LANDINGS SHALL SLOPE AWAY FROM THE DOOR MIN 1/4" PER FOOT. ALL LUMBER AND PLYWOOD WILL BE GRADE STAMPED BY AN APPROVED INSPECTION ANGENCY. ALL STRUCTURAL MATERIALS OF CONSTRUCTION TO COMPLY WITH THE CODE [CBC] TWO LAYERS OF GRADE D PAPER SHALL BE APPLIED OVER ALL WOOD BASE SHEATHING. THESE PLANS AND ALL WORK SHALL COMPLY WITH THE CALIFORNIA BUILDING STANDARDS CODE FOUND IN STATE OF CALIFORNIA TITLE 24 CCR CHECK WITH OWNER FOR COFFERED CEILINGS,LIGHT SOFFITS, SOFFITS FOR HEAT VENTS, CABINETS SHOWERS,TUBS, ECT. OWNER TO CHECK WITH THE HEATING CONTRACTOR FOR THE PLACEMENT OF THE HEATING DUCTS. AND THE AREA REQUIRED TO BE SOFFITED OR FURRED DOWN. ALL NEW GLAZING [ FENESTRATIONS ] WILL BE INSTALLED WITH A CERTIFYING LABEL ATTACHED, SHOW THE U VALUE. CHECK WITH PLUMBING CONTRACTOR FOR ANY PLUMBING WALLS THAT WOULD NEED TO BE A 6" WALL. CHECK WITH THE OWNER FOR OPTIONAL 6" EXTERIOR WALLS. INSTALL WATER FOR ICE MAKER IN THE REFRIGERATOR AREA. TUB AND SHOWER TO HAVE TILE INSTALLED 70" HIGH ABOVE THE FLOOR MIN. PROVIDE LOW FLUSH TOILETS (1.28GAL.) ALL WATER CLOSETS INSTALLED ON THIS PROJECT TO BE STATE OF CALIFORNIA, DEPARTMENT OF HOUSING & COMMUNITY DEVELOPMENT APPROVED LOW WATER CONSUMPTION TYPE MAXIMUM 1.6 GALLONS PER FLUSH ALL WATER HEATERS REQUIRE A MINIMUM OF 2 STRAPS [ ONE STRAP AT TOP 1/3 OF THE TANK AND ONE STRAP AT BOTTOM 1/3 OF TANK] TO RESIST HORIZONTAL DISPLACEMENT. STRAPS TO BE A MINIMUM OF 3/4" X24 GAUGE STRAPS WITH 1/4" X 3" LAG BOLTS ATTACHED DIRECTLY TO THE FRAMING [C.P.C. SEC 508.2] SPECIFY 15# FELT UNDER WOOD SIDING IN SHOWERS AND TUB-SHOWER COMBINATIONS, CONTROL VALVES MUST BE PRESSURE BALANCED OR THERMOSTATIC MIXING VALVES. CBC * BALLOON FRAME ALL WALLS OF ROOMS WITH SLOPING CEILINGS * MAXIMUM UNBRACED HEIGHT OF LATERALLY UNSUPPORTED, 2X4,3X4,2X6, STUDS IS 10'0" FOR BEARING WALLS * MAXIMUM UNBRACED HEIGHT OF LATERALLY UNSUPPORTED STUDS FOR NON-BEARING WALLS IS AS FOLLOWS: [A] 2X4 AND 3X4 IS 14' [B] 2X6] IS 20' DOUBLE TOP PLATE TO HAVE A MIN. 48" LAP SPLICE ALL DOOR HEADER TO BE 4X10 UNLESS NOTED OTHERWISE CROSS BRIDGING OR BLOCKING AT FLOOR JOISTS AND RAFTERS 12" OR MORE IN DEPTH SHALL BE SUPPORTED LATERALLY BY BRIDGING AT INTERVALS NOT EXCEEDING 8'0" , UNLESS BOTH EDGES ARE HELD INLINE. IN 2-STORY BUILDINGS, SHEAR PANELS AT THE FIRST STORY [AT LEAST 48" IN WIDTH] SHALL BE LOCATED AT EACH END OR AS NEAR THERETO AS POSSIBLE AND COMPRISE AT LEAST 25 PERCENT OF THE LINEAR LENGTH OF THE WALL, OR PROVIDE DESIGN. WINDOW AREA MUST BE 8% OF THE FLOOR AREA, OF THE ROOM SERVED (C.B.C.1205.2). TEMPERED SAFETY GLASS IS REQUIRED PER CBC 2406.4 1]IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS. GLAZING IN ANY PORTION OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60" ABOVE A STANDING SURFACE AND DRAIN INLET. 2] IN FIXED OR OPERABLE PANELS ADJACENT TO A DOOR WHERE THE NEAREST EXPOSED EDGE OF THE GLAZING IS WITHIN A 24" ARC OF EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60" ABOVE THE WALKING SURFACE. HINGED SHOWER DOORS MUST SWING OUTWARD. THRESHOLDS TO BE WIDE ENOUGH FOR A MINIMUM 22" WIDE DOOR AND 22" WIDE MAINTAINED EGRESS. OPENABLE WINDOW AREA TO THE OUTDOORS OF AT LEAST 4% OF THE ROOM SERVED (C.B.C.1203.4). SLEEPING ROOMS AND BASEMENTS MUST HAVE AN EXTERIOR EGRESS DOOR OR WINDOW [CBC 1026.2, 1026.3, 1026.5 ] WITH: (U.B.C. SEC. 310.4 ) : A) 5.7 SQ. FT. MINIMUM NET CLEAR OPENABLE AREA [ 5.0 SQ. FT.. FOR GRADE-LEVEL OPENINGS ] B) 24" MINIMUM NET CLEAR OPENABLE HEIGHT, C) 20" MINIMUM NET CLEAR OPENABLE WIDTH, D) BOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44" ABOVE FLOOR, E) DIRECT OPENING TO PUBLIC WAY OR YARD/COURT OPENING TO PUBLIC WAY, F) WINDOW WELLS OF 9 SQ. FT.. HORIZONTAL AREA AND 36" MINIMUM DIMENSIONS AND EQUIPPED WITH LADDERS/ STEPS FOR ESCAPE. PRIOR TO CONSTRUCTION THE FRAMING CONTRACTOR AND THE HEATING CONTRACTOR ARE TO DETERMINE WHERE THE HEATING DUCTS, RETURN AIR, ECT. ARE TO GO. DOUBLE TOP PLATE TO HAVE A 48" MIN. LAP SPLICE PROVIDE 8-16d LAP SPICE NAILING MIN. CBC. 2308.9.2.1. WHERE TOP PLATES OR SOLE PLATES ARE CUT FOR PIPES, A METAL TIE MINIMUM OF "0.058" INCHES THICK AND "1-1/2" INCHES WIDE SHALL BE FASTENED ACROSS THE OPENING WITH 6-16d NAILS MINIMUM EACH SIDE. CBC FIRE STOPS AT THE FOLLOWING LOCATIONS PER CBC 708. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND AT 10' FOOT INTERVALS ALONG THE LENGTH OF THE WALL; B. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS AND COVE CEILINGS; C. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN AND BETWEEN STUDS ALONG AND INLINE WITH THE RUN OF STAIRS IF THE WALLS UNDER THE STAIRS ARE UNFINISHED; AND D. IN OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS, FIREPLACES AND SIMILAR OPENINGS WHICH AFFORD A PASSAGE FOR FIRE AT CEILING AND FLOOR LEVELS, WITH NONCOMBUSTIBLE MATERIALS. E. AT OPENINGS BETWEEN ATTIC SPACES AND CHIMNEY CHASES FOR FACTORY-BUILT CHIMNEYS . THE PLUMBING FIXTURES AND PLUMBING FITTINGS SHALL MEET THE STANDARDS NOTED BELOW TO MEET THE CAL GREEN 20% INDOOR WATER SAVINGS: 1] WATER CLOSET, GRAVITY TANK-TYPE, FLUSHOMETER TANK TYPE, ELECTROMECHANICAL HYDRAULIC TYPE = 1.28 GALLONS PER FLUSH MAX. 2] SHOWER HEAD = 2.0 GPM MAX. 3] KITCHEN FAUCETS = 1.8 GPM MAX. 4]LAVATORY FAUCETS= 1.5 GPM MAX. 5] URINALS .5 GALLONS PER FLUSH ] IN SHOWERS AND TUB-SHOWER COMBINATIONS, CONTROL VALVES MUST BE PRESSURE BALANCED OR THERMOSTATIC MIXING VALVES. CPC 6]PERMANENT VACUUM BREAKERS SHALL BE INSTALLED WITH ALL NEW HOSE BIBS. TEMPERED GLASS TEMPERED GLASSTEMPERED GLASSTEMPERED GLASS TEMPERED GLASS TEMPERED GLASS TEMPERED GLASS TEMPERED GLASS TEMPERED GLASS NOTE: PROVIDE GAS & ELECTRIC FOR F.A.U. IN ATTIC. NOT MORE THAN 20'0” FROM THE ATTIC ACCESS INSTALL OVERHEAD LIGHT & F.A.U. PLATFORM IN ATTIC. PASSAGEWAY TO THE ATTIC F.A.U. SHALL BE UNOBSTRUCTED AND SHALL HAVE CONTINUOUS SOLID FLOORING NOT LESS THAN 24" WIDE. COMBUSTION AIR FOR F.A.U. WILL BE TAKEN FROM THE ATTIC AREA. ATTIC ACCESS OPENING SHALL BE SIZED FOR THE REMOVAL OF THE LARGEST PIECE OF EQUIPMENT. PERMANENT ELECTRICAL OUTLET AND LIGHTING FIXTURE CONTROLLED BY A SWITCH FOR FURNACE LOCATED IN ATTIC OR UNDERFLOOR AREA SEC. 319.6 AND 320.1 UMC WORKING AREA IN FRONT OF F.A.U. TO BE UNOBSTRUCTED FOR 30" MIN. ATTIC INSTALLED HVAC EQUIPMENT SHALL COMPLY WITH SEC. 305 &319,307.4,703.1 UMC. FURNACE SHALL NOT BE INSTALLED IN ANY BEDROOM, BATHROOM OR IN A CLOSET OR CONFINED SPACE WITH ACCESS ONLY THROUGH SUCH ROOM UNLESS SPECIFIED AS DIRECT VENT APPLIANCE, ENCLOSED FURNACE OR ELECTRIC HEATING APPLIANCE. FURNACE INSTALLATIONS MUST COMPLY WITH UMC CHAPTER #3 AND UPC CHAPTER 507 , AND UMC I 8 I 8 8 L 8 L 24'7" (760) 724-4159 DRAWING NUMBER SCALE: DATE: OWNERS NAME CONTRACTOR:DRAWN BY: APN. OF OWNERS PHONE# RONS HOUSE PLANS 5A 1/4"=1'0" 10-31-16 (760) 518-6571MIIKE WEST RTL 41'10" 2'6" 13'2" 14'9" 3'11'9" 3' 6'8" 21'5" 16'1" 5'9" 5'2" 14'9"21'6"20' 80'10" EXISTING 8'0"X5'0" NEW 5'0"X4'0" SLEXISTING 6'0"X4'0" EXISTING 2'6"X3'6" SH EXISTING 5'0"X3'0" EXISTING 2'0"X2'0" EXISTING MASTER SUITE EXISTING GARAGE 3'7" 16'5" WINDOW, SLIDING, GLASS DOOR OR MIRROR DOOR NEW FULL HEIGHT WALLS EXISTING FULL HEIGHT WALLS SHELF AND POLE HANDRAIL OR PARTIAL WALL HEADER OR WALL OPENINGS RETAINING WALLS FLOOR PLAN LEGEND 8'3"+OR- CEILING 14'10"24'7"20' 80'10" 5'0"X2'6" TUB & SHOWER 2'6" 13'5" 11'6"10' NEW 5'0"X4'0" SL 10'6" 5' 10'8" VAULTED CEILING REMOVE EXISTING 5'0"X3'6" NEW BEDROOM VAULTED CEILINGWASHERDRYER TANKLESS WATER HEATER ABOVE 3'7" 3' 9'4" 20' FILL IN 3'0" OPENING 4'8" 3'4" WH 10' 15' EXISTING DECK 5' 22' 8' 16'6" 12' 22' NEW GARAGE 8'3"+OR- CEILING 2'8'2' 20' 16'0"X7'0" SECTIONAL STEEL DOOR 8'0"X7'0" SECTIONAL STEEL DOOR 3 0 NEW ENTRY15' 7'17'7" UP 4 RISERS NEW PORCH DN 1 RISER NEW MEDIA ROOM 26 2'6" 12'6" NEW BEDROOM VAULTED CEILING 5' 3'6"4' 5'0"X6'8" MIRROR DOOR 5'0"X6'8" MIRROR DOOR 7'6"6'6" REMOVE KITCHEN AND NON BEARING WALLS 2'5'0"X2'6"TUB &SHOWER3' 26SINK NEW 2'0"X3'0" SH DN 4 RISERS 28 4'6" 5' 12' 10' 35'6" 19' 5' 3 025'10" 16'1" #2778 EXISTING 5'0"X3'0"5'0"X2'6"TUB &SHOWERLINEN GENERAL NOTES 1. DIMENSIONS DERIVED FROM PREVIOUS PLANS PROVIDED BY THE OWNER. 2. FIELD VERIFY DIMENSIONS PRIOR TO ENGINEERING, CONSTRUCTION & SUBMITTING FOR PERMITS. 3. BUILDING PERMIT SUBMITTAL & APPROVAL REQUIRED PRIOR TO ANY MODIFICATION OR CONSTRUCTION WHICH IS REQUIRED TO MEET CURRENT BUILDING CODES & REGULATIONS IN THE ZONED AREA OF SUBJECT PROPERTY 5A NEW 2ND FLOOR PLAN SCALE 1/4" = 1'0" NEW 10'0"X8'0" SL NEW 6'0"X6'0" SL DN 18 RISERS NEW PORCH NEW MASTER SUITE NEW 3'0"X6'0" FIXED NEW 2'0"X3'0" SH NEW 2'6"X4'6" FIXED 798.75 ft2 14'6" 7'6" NEW MASTER SITTIING AREA 4' 3'6" 5'6"7'6"3'6" 26 6' 4' BASE CAB OVER ANGLED FLOOR 2 4 3' LINEN & HAMPER 2'6" 9'3/4" CEILING9'3/4" CEILING 13' 35'6" 3 0 4' 7' 3'6" NEW 2'6"X4'6" FIXED 4'15' NEW 2ND FLOOR AREA_______________ NEW 2ND FL DECK_____________________284.00 ft2 4' OPENING 28 3' NEW 2'6"x1'0" SL NEW 2'6"x1'0" SL NEW 2'6"x1'0" SL NEW 2'6"x1'0" SL 3 0 16'6" 3' 6'3'6"9"6'6"10'2'6"3"3' 9" 2' 1'9" 2'6"12'1'6"2'6"4'3" 6' 2'6" 2'6" NOTE: PROVIDE GAS & ELECTRIC FOR F.A.U. IN ATTIC. NOT MORE THAN 20'0” FROM THE ATTIC ACCESS INSTALL OVERHEAD LIGHT & F.A.U. PLATFORM IN ATTIC. PASSAGEWAY TO THE ATTIC F.A.U. SHALL BE UNOBSTRUCTED AND SHALL HAVE CONTINUOUS SOLID FLOORING NOT LESS THAN 24" WIDE. COMBUSTION AIR FOR F.A.U. WILL BE TAKEN FROM THE ATTIC AREA. ATTIC ACCESS OPENING SHALL BE SIZED FOR THE REMOVAL OF THE LARGEST PIECE OF EQUIPMENT. PERMANENT ELECTRICAL OUTLET AND LIGHTING FIXTURE CONTROLLED BY A SWITCH FOR FURNACE LOCATED IN ATTIC OR UNDERFLOOR AREA SEC. 319.6 AND 320.1 UMC WORKING AREA IN FRONT OF F.A.U. TO BE UNOBSTRUCTED FOR 30" MIN. ATTIC INSTALLED HVAC EQUIPMENT SHALL COMPLY WITH SEC. 305 &319,307.4,703.1 UMC. FURNACE SHALL NOT BE INSTALLED IN ANY BEDROOM, BATHROOM OR IN A CLOSET OR CONFINED SPACE WITH ACCESS ONLY THROUGH SUCH ROOM UNLESS SPECIFIED AS DIRECT VENT APPLIANCE, ENCLOSED FURNACE OR ELECTRIC HEATING APPLIANCE. FURNACE INSTALLATIONS MUST COMPLY WITH UMC CHAPTER #3 AND UPC CHAPTER 507 , AND UMC 17'9"17'9" 9'3"+OR- CEILING FAU IN ATTIC ATTICACCESS22"X36"K 8 K 8 G 11 F 11 A 8 FOR EGRESS DOORS: MAX . 7.75 INCHES FOR IN-SWINGING DOORS FROM TOP OF THRESHOLD TO LANDING AND 1.5 INCHES FOR OUT-SWINGING FOR NON-REQUIRED DOORS: IN OR OUT SWINGING 7.75 INCHES LANDINGS AT DOORS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF DOOR AND LENGTH IN THE DIRECTION OF TRAVEL OF NOT LESS THAN 36", WILL BE PROVIDED ON EACH SIDE OF DOORS. THE ELEVATION OF LANDING SHALL NOT EXCEED ONE INCH DIFFERENCE THAN THE THRESHOLD OF THE DOORWAY[ 8" IF DOOR DOES NOT SWING OVERT THE LANDING]. ALL LANDINGS SHALL SLOPE AWAY FROM THE DOOR MIN 1/4" PER FOOT. ALL LUMBER AND PLYWOOD WILL BE GRADE STAMPED BY AN APPROVED INSPECTION ANGENCY. ALL STRUCTURAL MATERIALS OF CONSTRUCTION TO COMPLY WITH THE CODE [CBC] TWO LAYERS OF GRADE D PAPER SHALL BE APPLIED OVER ALL WOOD BASE SHEATHING. THESE PLANS AND ALL WORK SHALL COMPLY WITH THE CALIFORNIA BUILDING STANDARDS CODE FOUND IN STATE OF CALIFORNIA TITLE 24 CCR CHECK WITH OWNER FOR COFFERED CEILINGS,LIGHT SOFFITS, SOFFITS FOR HEAT VENTS, CABINETS SHOWERS,TUBS, ECT. OWNER TO CHECK WITH THE HEATING CONTRACTOR FOR THE PLACEMENT OF THE HEATING DUCTS. AND THE AREA REQUIRED TO BE SOFFITED OR FURRED DOWN. ALL NEW GLAZING [ FENESTRATIONS ] WILL BE INSTALLED WITH A CERTIFYING LABEL ATTACHED, SHOW THE U VALUE. CHECK WITH PLUMBING CONTRACTOR FOR ANY PLUMBING WALLS THAT WOULD NEED TO BE A 6" WALL. CHECK WITH THE OWNER FOR OPTIONAL 6" EXTERIOR WALLS. INSTALL WATER FOR ICE MAKER IN THE REFRIGERATOR AREA. TUB AND SHOWER TO HAVE TILE INSTALLED 70" HIGH ABOVE THE FLOOR MIN. PROVIDE LOW FLUSH TOILETS (1.28GAL.) ALL WATER CLOSETS INSTALLED ON THIS PROJECT TO BE STATE OF CALIFORNIA, DEPARTMENT OF HOUSING & COMMUNITY DEVELOPMENT APPROVED LOW WATER CONSUMPTION TYPE MAXIMUM 1.6 GALLONS PER FLUSH ALL WATER HEATERS REQUIRE A MINIMUM OF 2 STRAPS [ ONE STRAP AT TOP 1/3 OF THE TANK AND ONE STRAP AT BOTTOM 1/3 OF TANK] TO RESIST HORIZONTAL DISPLACEMENT. STRAPS TO BE A MINIMUM OF 3/4" X24 GAUGE STRAPS WITH 1/4" X 3" LAG BOLTS ATTACHED DIRECTLY TO THE FRAMING [C.P.C. SEC 508.2] SPECIFY 15# FELT UNDER WOOD SIDING IN SHOWERS AND TUB-SHOWER COMBINATIONS, CONTROL VALVES MUST BE PRESSURE BALANCED OR THERMOSTATIC MIXING VALVES. CBC * BALLOON FRAME ALL WALLS OF ROOMS WITH SLOPING CEILINGS * MAXIMUM UNBRACED HEIGHT OF LATERALLY UNSUPPORTED, 2X4,3X4,2X6, STUDS IS 10'0" FOR BEARING WALLS * MAXIMUM UNBRACED HEIGHT OF LATERALLY UNSUPPORTED STUDS FOR NON-BEARING WALLS IS AS FOLLOWS: [A] 2X4 AND 3X4 IS 14' [B] 2X6] IS 20' DOUBLE TOP PLATE TO HAVE A MIN. 48" LAP SPLICE ALL DOOR HEADER TO BE 4X10 UNLESS NOTED OTHERWISE CROSS BRIDGING OR BLOCKING AT FLOOR JOISTS AND RAFTERS 12" OR MORE IN DEPTH SHALL BE SUPPORTED LATERALLY BY BRIDGING AT INTERVALS NOT EXCEEDING 8'0" , UNLESS BOTH EDGES ARE HELD INLINE. IN 2-STORY BUILDINGS, SHEAR PANELS AT THE FIRST STORY [AT LEAST 48" IN WIDTH] SHALL BE LOCATED AT EACH END OR AS NEAR THERETO AS POSSIBLE AND COMPRISE AT LEAST 25 PERCENT OF THE LINEAR LENGTH OF THE WALL, OR PROVIDE DESIGN. WINDOW AREA MUST BE 8% OF THE FLOOR AREA, OF THE ROOM SERVED (C.B.C.1205.2). TEMPERED SAFETY GLASS IS REQUIRED PER CBC 2406.4 1]IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS. GLAZING IN ANY PORTION OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60" ABOVE A STANDING SURFACE AND DRAIN INLET. 2] IN FIXED OR OPERABLE PANELS ADJACENT TO A DOOR WHERE THE NEAREST EXPOSED EDGE OF THE GLAZING IS WITHIN A 24" ARC OF EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60" ABOVE THE WALKING SURFACE. HINGED SHOWER DOORS MUST SWING OUTWARD. THRESHOLDS TO BE WIDE ENOUGH FOR A MINIMUM 22" WIDE DOOR AND 22" WIDE MAINTAINED EGRESS. OPENABLE WINDOW AREA TO THE OUTDOORS OF AT LEAST 4% OF THE ROOM SERVED (C.B.C.1203.4). SLEEPING ROOMS AND BASEMENTS MUST HAVE AN EXTERIOR EGRESS DOOR OR WINDOW [CBC 1026.2, 1026.3, 1026.5 ] WITH: (U.B.C. SEC. 310.4 ) : A) 5.7 SQ. FT. MINIMUM NET CLEAR OPENABLE AREA [ 5.0 SQ. FT.. FOR GRADE-LEVEL OPENINGS ] B) 24" MINIMUM NET CLEAR OPENABLE HEIGHT, C) 20" MINIMUM NET CLEAR OPENABLE WIDTH, D) BOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44" ABOVE FLOOR, E) DIRECT OPENING TO PUBLIC WAY OR YARD/COURT OPENING TO PUBLIC WAY, F) WINDOW WELLS OF 9 SQ. FT.. HORIZONTAL AREA AND 36" MINIMUM DIMENSIONS AND EQUIPPED WITH LADDERS/ STEPS FOR ESCAPE. PRIOR TO CONSTRUCTION THE FRAMING CONTRACTOR AND THE HEATING CONTRACTOR ARE TO DETERMINE WHERE THE HEATING DUCTS, RETURN AIR, ECT. ARE TO GO. DOUBLE TOP PLATE TO HAVE A 48" MIN. LAP SPLICE PROVIDE 8-16d LAP SPICE NAILING MIN. CBC. 2308.9.2.1. WHERE TOP PLATES OR SOLE PLATES ARE CUT FOR PIPES, A METAL TIE MINIMUM OF "0.058" INCHES THICK AND "1-1/2" INCHES WIDE SHALL BE FASTENED ACROSS THE OPENING WITH 6-16d NAILS MINIMUM EACH SIDE. CBC FIRE STOPS AT THE FOLLOWING LOCATIONS PER CBC 708. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND AT 10' FOOT INTERVALS ALONG THE LENGTH OF THE WALL; B. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS AND COVE CEILINGS; C. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN AND BETWEEN STUDS ALONG AND INLINE WITH THE RUN OF STAIRS IF THE WALLS UNDER THE STAIRS ARE UNFINISHED; AND D. IN OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS, FIREPLACES AND SIMILAR OPENINGS WHICH AFFORD A PASSAGE FOR FIRE AT CEILING AND FLOOR LEVELS, WITH NONCOMBUSTIBLE MATERIALS. E. AT OPENINGS BETWEEN ATTIC SPACES AND CHIMNEY CHASES FOR FACTORY-BUILT CHIMNEYS . THE PLUMBING FIXTURES AND PLUMBING FITTINGS SHALL MEET THE STANDARDS NOTED BELOW TO MEET THE CAL GREEN 20% INDOOR WATER SAVINGS: 1] WATER CLOSET, GRAVITY TANK-TYPE, FLUSHOMETER TANK TYPE, ELECTROMECHANICAL HYDRAULIC TYPE = 1.28 GALLONS PER FLUSH MAX. 2] SHOWER HEAD = 2.0 GPM MAX. 3] KITCHEN FAUCETS = 1.8 GPM MAX. 4]LAVATORY FAUCETS= 1.5 GPM MAX. 5] URINALS .5 GALLONS PER FLUSH ] IN SHOWERS AND TUB-SHOWER COMBINATIONS, CONTROL VALVES MUST BE PRESSURE BALANCED OR THERMOSTATIC MIXING VALVES. CPC 6]PERMANENT VACUUM BREAKERS SHALL BE INSTALLED WITH ALL NEW HOSE BIBS. TEMPERED GLASS TEMPERED GLASS TEMPERED GLASS TEMPERED GLASS TEMPERED GLASS TEMPERED GLASS TEMPERED GLASSTEMPERED GLASS TEMPERED GLASS G 11