HomeMy WebLinkAboutPRE 2020-0039; LA COSTA VILLAS LOT 399; Admin Decision LetterJanuary 7, 2021 Riccardo Ferguson MAA Architects 330 Rancheros Drive, Suite 110 San Marcos, CA 92069 SUBJECT: PRE 2020-0039 (DEV2020-0310)-LA COSTA VILLAS LOT 399 APN: 216-300-06-00 Dear Mr. Ferguson, Ccityof Carlsbad 8FILE COPY rr,,.,-JeJ ,1,1./-i., Thank you for submitting a preliminary review application for a nine (9) unit airspace condominium project proposed on a previously graded parcel located on the south side of Gibraltar Street, east of its intersection with Jerez Court. The project site, an approximately 0.4-acre site, currently is vacant. The development proposal includes a parking garage with 20 parking spaces and three (3) residential floors above (three (3) units per floor). In response to your application, the Planning Division has prepared this comment letter. Please note that the purpose of a preliminary review is to provide you with direction and comments on the overall concept of your project. This preliminary review does not represent an in-depth analysis of your project. It is intended to give you feedback on critical issues based upon the information provided in your submittal. This review is based upon the plans, policies. and standards in effect as of the date of this review. Please be aware that at the time of a formal application submittal, new plans, policies. and standards may be in effect and additional issues of concern may be raised through a more specific and detailed review. Planning: General 1. General Plan and zoning designations for the property are as follows: a. General Plan: R-23 Residential, 15-23 units/acre. Growth Management Control Point of 19 units/ac. b. Zoning: Residential Density-Multiple (RD-M) 2. The project requires the following permits: a. Carlsbad Tract Map (CT) b. Planned Development Permit (PUD) Community Development Department Planning Division I 1635 Faraday Avenue Carlsbad, CA 92008-7314 I 760-602-4600 I 760-602-8560 f I www.carlsbadca.gov · PRE 2020-0039 (DEV2020-0310)-LA COSTA VILLAS/LOT 399 January 7, 2021 Pa e 2 3. The Housing Crisis Act of 2019 (SB 330) established a preliminary streamline application process for housing projects. It is not mandatory unless applicants seek the vesting and processing benefits offered under SB 330. Participation in the SB 330 streamline process would occur first, followed by the formal development application process required under Government Code (Gov. Code) §§65940, 65941,65941.S~and Carlsbad Municipal Code (CMC) §21.42.050. Acceptance by the city of a complete SB 330 Streamline Application (Form P-32) and fee will vest the project for 180 days in accordance with the ordinances, policies and standards in effect at the time the SB 330 Application is accepted. The city is finalizing the application form and process for SB 330 Streamline Applications. Please contact planning@carlsbadca.gov for more information. 4. Per the Housing Crisis Act of 2019 (SB 330), any project that includes the removal or demolition of a "protected unit" is required to provide the occupants with 1) relocation benefits (Gov. Code § 7260 et seq.), and 2) right of first refusal for a comparable unit available in the new housing development. (Gov. Code §66300 (d)(2)(D).) "Protected units" are generally defined by Gov. Code §66300{d)(2)(E)(ii) as including residential units subject to affordability restrictions, price controls, or occupied by low income households. The formal submittal of the project will need to include documentation regarding any existing "protected units." 5. New requirements related to the city's goals to reduce greenhouse gas (GHG) emissions will likely impact development requirements of this project. A formal application submittal will need to include a completed Climate Action Plan Checklist (Form P-30) to determine what requirements will apply to the project. New GHG reduction requirements are related to energy efficiency, photovoltaic, electric vehicle charging, water heating and traffic demand management requirements, as set forth in the California Green Building Standards Code and in CMC Chapters 18.21, 18.30 and 18.51 which is available on the city's website at the following address: http://www.gcode.us/codes/carlsbad/view.php?topic=18&frames=on To the extent that new GHG reduction _requirements are in effect at the time of application for grading or building permits, the project will be required to comply with the effective requirements even if different than what is proposed in the project's planning approvals. GHG reduction requirements may impact, but are not limited to, site design and local building code requirements. If incorporating new GHG reduction requirements results in substantial modifications to the project after planning approvals are obtained, then prior to issuance of grading or building permits, the applicant may be required to submit and receive approval of a Consistency Determination or an Amendment application for the project through the Planning Division. 6. The 0.4-acre previously graded project site has a General Plan Land Use designation of R-23 Residential {15 to 23 dwelling units per acre (du/ac) with a Growth Management Control Point (GMCP) of 19 du/ac). With a proposed project density of 22.5 du/ac, the proposed nine (9) unit multi-family residential project is exceeding the GMCP; and thus, will need to be found compliant with General Plan Residential Policy 2-P.8 and also qualify for and receive an allocation of "excess" dwelling units pursuant to City Council Policy No. 43. These policies can be reviewed on the city website at: General Plan Land Use Element: https://www.carlsbadca.gov/civicax/fi1ebank/blobdload.aspx?Blob1D-24087 PRE 2020-0039 (DEV2020-0310) -LA COSTA VILLAS/LOT 399 January 7, 2021 Pa e 3 City Council Policy 43: https://www.carlsbadca.gov/civicax/filebank/blobdload.aspx?Blob1D=24068 7. Hillside Development. The project site is considered a hillside lot because it includes a change in grade elevation greater than 15 feet and slopes greater than 15 percent. However, because the subject lot was developed as part of a previous subdivision and grading permit, the subject project is exempt from having to obtain a Hillside Development Permit (HDP) pursuant CMC §21.95.040.A.2. While a formal submittal of this project would be exempt from the processing of a HDP, the project will still need to demonstrate conformance with the Hillside Development Regulations and Hillside Development & Design Guidelines. As part of a formal submittal, please be sure that project exhibits address all requirements listed under CMC §21.95.130 -Hillside Mapping Procedures and CMC §21.95.140 -Hillside Development and Design Standards. The Hillside Development & Design Guidelines may be found and reviewed on the city website at: http://www.carlsbadca.gov/civicax/filebank/blobdload.aspx?Blob1D=24084 8. As it relates to the Hillside Development Regulations, the proposed project appears to be proposing development into an uphill perimeter slope with the proposed building encroaching into the tow of the slope and a retaining wall greater than six (6) feet in height. To develop as proposed, the formal submittal would need to demonstrate that the subject slope does not meet the criteria in CMC §21.95.140.C.1.a. 9. Trash and Recycling. As part of a formal submittal, please provide a will serve letter from the local waste management service company indicating that it can adequately service this project from inside the parking garage as proposed. 10. lnclusionarv Housing. The 9-unit condominium building is required to provide 1-unit as affordable pursuant to CMC §21.85.050. As part of a formal submittal, please identify the affordable unit within the plans. 11. Building height. The proposed podium style parking garage does not appear to meet the definition of a basement as currently proposed; and therefore, the building is exceeding the 40-foot maximum height and is also considered four stories. For the parking garage to be considered a basement and exempted from the building height measurement, the podium design will need to meet certain requirements. Please review the Planning Division's Guide. to Measuring Building Height, which can be reviewed on the city website at: https:ljwww.carlsbadca.gov/civicax/filebank/blobdload.aspx?Blob1D=24062 12. Height Limit Line. As it relates to building height, the height limit line needs to parallel the existing or proposed grade, whichever is lower. See examples in the Planning Division's Guide to Measuring Building Height as discussed above. 13. Planned Development Permit. As part of the Planned Development Permit, the project will be subject to the General Development Standards found in Tables C (CMC §21.45.060) and those for Condominiums found in Table E (CMC §21.45.080). PRE 2020-0039 (DEV2020-0310) -LA COSTA VILLAS/LOT 399 January 7, 2021 Pa e4 As it relates to Table C, staff observed the following issues with the project: a. A 9-unit residential project requires three (3) visitor parking spaces. The project is proposing these spaces in the public street yet does not provide any information to determine if the requirements outlined in Table C have been met to allow for this. Please review parallel parking standards in Chapter 21.44 to determine if the project frontage will provide enough lineal space to accommodate the three (3) parking spaces along the street with the addition of the new driveway and line-of-sight requirements. b. Please identify how the project is meeting its lighting requirements with respect to pedestrian and vehicular safety. As part of the architecture, please also consider additional decorative lighting that will accentuates various architectural features and enhance the overall street scene. As it relates to Table E, staff observed the following issues with the project: c. See building height discussion above. For the pitched roof to be allowed to extend up to up to 40 feet in height, the project would need to provide a minimum 3:12 roof pitch. The roof pitch is not labelled on the plans but will need to be in a formal submittal. See roof plan requirements on the project application forms prior to making a formal submittal. d. Four stories are prohibited. See building height discussion above. e. For the flat roof areas {less than 3:12 roof pitch) associated with the patio covers, those would not be allowed to exceed a maximum height of 35 feet. With a formal submittal, please update the plans to identify the building height dimension and height limit line. 13. Compliance with City Council Policy 66 -Principles for the Development of livable Neighborhoods is a requirement of the Planned Development Table E. This policy can be reviewed on the city website at: https://www.carlsbadca.gov/civicax/filebank/blobdload.aspx?Blob1D=24736 The first principle, discussing building facades,front entries, porches, emphasizes projects with clearly visible front doors and porches to enhance the street scene and create opportunities for greater social interaction within the neighborhood. This principle is not being met by the current project design and will need revision. As a suggestion, the podium design as proposed offers opportunity for perhaps a design that is reminiscent of a traditional brownstone design with direct interaction with the pedestrian sidewalk and street scene. A formal submittal of this proposal will also be routed the Police Department who may have additional concern with the units being accessed from the rear of the property via long corridors along the sides of the building. The fourth principle, discussing parkways will also need to be addressed in a formal submittal. PRE 2020-0039 (DEV2020-0310)-LA COSTA VILLAS/LOT 399 January 7, 2021 Pa e 5 14. With a formal submittal, the Planning Division will require the following reports: a. Noise Report. The project is located within the 60 dB(A) CNEL contour noise contour line of the Noise Contour Map approved as part of the Carlsbad General Plan and is proposing more than five units. Please provide a noise report in accordance with the requirements of the City of Carlsbad Noise Manual. For more information, the manual can be reviewed on the city website at: https://www.carlsbadca.gov/civicax/filebank/b1obdload.aspx?Blob1D=24094 b. Biological Study. A formal submittal of this project will need to include a biological study of the site demonstrating compliance with the City of Carlsbad's Habitat Management Plan (HMP) and Guidelines for Biological Studies. Both above documents can be reviewed on the city website at: HMP: https://www.carlsbadca.gov/civicax/filebank/blobdload.aspx?Blob1D=27193 Guidelines for Biological Studies: http:ljwww.carlsbadca.gov/civicax/fi1ebank/blobdload.aspx?Blob1D=24331 c. Cultural Resources/Paleontological Studies. The development of the proposed project will require excavation that could potentially impact archeological and paleontological resources. Please direct your consultant to the city's Tribal, Cultural and Poleontological Resources Guidelines. Please be aware that an archeological pedestrian survey of the site associated with the cultural resources study shall include a Native American monitor during the survey. For more information, the guidelines can be reviewed on the city website at: http://www.carlsbadca.gov/services/depts/planning/codes.asp All necessary application forms, submittal requirements, and fee information are available at the Planning counter located in the Faraday Building at 1635 Faraday Avenue or online at http:ljwww.carlsbadca.gov/services/depts/planning/default.asp. You may also access the General Plan Land Use Element and the Zoning Ordinance online at the website address shown; select Department Listing; select Planning Home Page. Please review all information carefully before submitting. Land Development Engineering: 1. Process a tentative subdivision map to create nine (9) airspace condominium units. 2. Complete a Storm Water Standards Questionnaire Form E-34 to determine storm water quality requirements for this project. The questionnaire is available in the city website at: http://www.carlsbadca.gov/services/depts/landev/engineering.asp PRE 2020-0039 (DEV2020-0310)-LA COSTA VILLAS/LOT 399 January 7, 2021 Pa e 6 3. Based on the preliminary plans, it appears the project qualifies as a Priority Development Project (PDP) and will be required to submit a preliminary Storm Water Quality Management Plan (SWQMP) with any discretionary application. The SWQMP shall be prepared in accordance with the City of Carlsbad BMP Manual (latest version). Use the City of Carlsbad SWQMP template for priority development project (Form E-35) available in _the City website. The project SWQMP will determine the pollutant control BMP requirements. Note that this project is subject to hydromodification standards. 4. A preliminary hydrology study will be required to determine the pre-development and post- development discharge flows. Provide preliminary recommendations on the proposed storm drain system to serve this project and to mitigate any increase in flows. 5. Provide a preliminary Geotechnical study that identifies feasibility and recommendations for the proposed development including design recommendations proposed pollutant control BMPs and hydromodification facilities. Due to the poor soil conditions in this area, a third-party review of the Geotechnical study will be required prior to discretionary approval. 6. A recent Preliminary Title Report (PTR) will be required with formal project application submittal. 7. All easements and encumbrances identified in the PTR must be indicated on the site plan. 8. Plot the site plan/tentative map so the north arrow is directed to the top of the sheets. 9. Show complete property boundary data on the site plan, including bearings, distances, and curve data. 10. Provide typical street cross section of Gibraltar Street showing existing improvements (pavement, curb, gutter, sidewalk, centerline, streetlights, fire hydrants, water, sewer, etc.). 11. On the site plan, show and identify all existing surface improvements (curb, gutter, sidewalk, paving, manholes, inlets, street lights, adjacent driveways, vaults, transformers, etc.) and all existing utilities (including watermain, water services, water meters, sewer main, sewer laterals, storm drain pipes, etc. and their appurtenances) along Gibraltar Street. Reference city approved improvement plan drawing numbers of the existing utilities for references. 12. Show the location of the proposed water service, water meter with backflow preventer and fire service with double detector check valve assembly. A single master water meter and backflow will serve the project. Plot individual water services from the backflow to each unit on the tentative map. 13. Show the location of the proposed sewer lateral to serve the project. Show the invert elevations to indicate gravity flow. 14. Show location of the electrical transformer that will serve the project outside of the public right-of- way. 15. Plot the corner sight distance at the driveway entrance on Gibraltar Street per CalTrans standards. PRE 2020-0039 (DEV2020-0310)-LA COSTA VILLAS/LOT 399 January 7, 2021 Pa e 7 16. Plot the full width of existing Gibraltar Street to include the intersection with Jerez Court and all existing driveways on the opposite side of the street. 17. Provide a preliminary grading plan to clearly show difference between proposed and existing grading, walls, drainage, storm drain, BM P's etc. for the project. 18. Show existing buildings and improvements for the development on the adjacent lot to the west, extend at least 50 feet beyond the property lines to include the existing driveway. 19. Extend the existing topography on the adjacent parcel to the south to include the existing buildings. Indicate existing finished floor elevations. 20. Provide multiple cross-sections of the site to demonstrate differences in grade, including adjacent properties, buildings, walls and adjacent streets. 21. Clearly show the locations and top and bottom of wall elevations for all retaining walls required for this project. 22. Meet with the Fire Department to identify the necessary fire protection measures required for this project (access, fire hydrants, sprinkler system, on-site circulation, emergency access, etc.) 23. The minimum driveway width for a multi-family residential development is 24 feet. 24. Plot location and dimensions of all accessways and pathways as required for compliance with Title 24 -State Accessibility Requirements. 25. Provide discussions summarizing the applicability of relevant screening criteria to this project as required by Section 3.2 of the (VMT) Guidelines. Include discussion of the project's trip generation, average daily traffic {ADT) calculations and how it applies to the VMT screening criteria (see section 3.2.1). 26. A letter will be required from Leucadia Wastewater District that this project is acceptable and sewer service will be provided. 27. Please be advised that in order to make a more in-depth review of the proposed development, a more complete design of the project is required. 1. It appears that the proposed building is out of access in accordance with the Fire Code by over SO feet. The applicant shall contact the fire department to discuss ways to bring the building within fire access requirements of considerations for an Alternate Means & Method Submittal. 2. Since this building is pedestal construction with the parking level being partially above ground, this structure will be considered four stories and all provisions for buildings greater that three stories shall be complied with by the applicant. PRE 2020-0039 (DEV2020-0310)-LA COSTA VILLAS/LOT 399 January 7, 2021 Pa e 8 Building: 1. One (1) van and one (1) standard accessible parking stall shall be required for the project as proposed. 2. The project will need to provide exterior accessible route and interior unit accessibility for covered multi-family dwelling units (all units). If you would like to schedule a meeting to discuss this letter with the commenting departments/divisions, please contact Jason Goff at the number below. You may also contact each department/division individually as follows: • Planning Division: Jason Goff, Senior Planner, at (760) 602-4643 • Land Development Engineering Division: Allison McLaughlin, Project Engineer, at (760} 602-2732 • Fire Department: Randy Metz, Fire Inspections, at (626} 536-6677 • Building Division: Jason Pasiut, Building Official, at (760) 602-2788 Sincerely, DON NEU, AICP City Planner DN:JG:cf c: La Costa AL C, LLC, Attn: Mike Massoodnia, 7668 El Camino Real #104-463, Carlsbad, CA 92009 Allison Mclaughlin, Land Development Engineering Randy Metz, Fire Prevention Jason Pasiut, Building Division HPRM/File Copy Data Entry