HomeMy WebLinkAbout2004 PERIDOT CT; ; CB072427; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
01-07-2008 Residential Permit Permit No: CB072427
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
2004 PERIDOT CT CBAD
RESDNTL
2132911100
Sub Type: Status:
Lot#: Applied:
Valuation·
Occupancy Group:
01/07/2008
$314,169.24 Construction Type:
SFD
19
VN Entered By:
ISSUED
09/20/2007
JMA
Reference #: CT 04-09 Plan Approved:
# Dwelling Units: 1 Structure Type: SFD Issued: 01/07/2008
Bedrooms: 4 Bathrooms: 4 Inspect Area:
Project Title: TRIESTE PL 2: PHS 4 2745SF LV, Orig PC#: PC 06-35
639SF GAR/110SF DECK/138SF LOG/120SF PORCH/103SF PATIO Plan Check#: PC 07-62
Applicant:
WARMINGTON HOMES
701 PALOMAR AIRPORT RD
CARLSBAD CA 92011
931-4766
Building Permit
Add'I Building Permit Fee
Plan Check
Add'IPlan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
HMP Fee
Pot. Water Con. Fee
Meter Size
Add'I Pot. Water Con. Fee
Reel. Water Con. Fee
$1,318.65
$0.00
$857.12
$0.00
($68.57)
$31.42
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$3,423.00
05/8
$0.00
$0.00
Owner:
WARMINGTON TRIESTE ASSOCIATES LP
C/O WARMINGTON HOMES CALIFORNIA
3090 PULLMAN ST#A
COSTA MESA CA 92626
Meter Size
Add'I Reel. Water Con. Fee
Meter Fee
SDCWAFee
CFO Payoff Fee
PFF (3105540)
PFF (4305540)
License Tax (3104193)
License Tax (4304193)
Traffic Impact Fee (3105541)
Traffic Impact Fee (4305541)
Sidewalk Fee
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Housing Impact Fee
Housing lnLieu Fee
Housing Credit Fee
Master Drainage Fee
Sewer Fee
Additional Fees
TOTAL PERMIT FEES
Total Fees: $20,693.13 Total Payments To Date: $20,693.13 Balance Due:
Inspector: kV': ~ FINAL APPRO~AL
'2,,'I C) g Date: Clearance:
$0.00
$160.00
$4,492.00
$3,618.63
$5,717.88
$0.00
$0.00
$0.00
$750.00
$0.00
$0.00
$259.00
$60.00
$74.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$20,693.13
$0.00
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reseNations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
· rm·
City of Carlsbad Bldg Inspection Request
For: 10/24/2008
Permit# CB072427 Inspector Assignment: MC
Title: TRIESTE PL 2: PHS 4 2745SF LV,
Description: 639SF GAR/11 0SF DECK/138SF LOG/120SF PORCH/103SF
PATIO
Type: RESDNTL Sub Type: SFD
---
Phone: 7604271926
Job Address: 2004 PERIDOT CT
Suite: Lot: 19
Location: Inspector: M,l, -----
APPLICANT WARMINGTON HOMES
Owner: WARMINGTON TRIESTE ASSOCIATES L P
Remarks:
Total Time:
CD Description
19
29
39
Final Structural
Final Plumbing
Final Electrical
49 Final Mechanical
Act Comments
Requested By: :KYLE
Entered By: JANEAN
£1_ _____________ _
Comments/Notices/Holds
Associated PCRs/CVs Original PC# PC 06-35
lnsgection Histo[l/
Date Description Act lnsp Comments
10/22/2008 89 Final Combo CA MC PER CONTRACTOR
09/24/2008 89 Final Combo PA MC OK TO RELEASE GAS
07/17/2008 39 Final Electrical AP MC EMR ONLY, OK TO RELEASE METER
06/12/2008 17 Interior Lath/Drywall AP PC
05/21/2008 17 Interior Lath/Drywall PA MC INT. DRYWALL ONLY
05/21/2008 18 Exterior Lath/Drywall AP MC
05/21/2008 23 Gas/Test!Repairs AP MC
05/14/2008 16 Insulation AP MC
05/12/2008 84 Rough Combo AP MC MINOR PICK UP
04/24/2008 13 Shear Panels/HO's AP MC
04/10/2008 15 Roof/Reroof AP MC OK TO DRY IN & LOAD
03/03/2008 11 Ftg/Foundation/Piers AP MC RECEIVED SOILS, PT & BLDG SET BACK REPORTS
03/03/2008 12 Steel/Bond Beam AP MC
' m City of Carlsbad Bldg Inspection Request
For: 07/17/2008 .
Permit# CB072427 Inspector Assignment: MC
Title: TRIESTE PL 2: PHS 4 2745SF LV,
Description: 639SF GAR/110SF DECK/138SF LOG/120SF PORCH/103SF
PATIO
Sub Type: SFD
---
Type: RESDNTL
Phone: 7604271926
Job Address: 2004 PERIDOT CT
Suite:
Location:
Lot: 19
Inspector: (V£c.. --'----
OWNER WARMINGTON TRIESTE ASSOCIATES LP
Owner: WARMINGTON TRIESTE ASSOCIATES LP
Remarks: EMR
Total Time:
CD Description
39 Final Electrical
Act Comments
Requested By: KYLE
Entered By: CHRISTINE
k ~ CN.t.-r( J Zllt--:to :IZF I p "<.:: £.1E;.:t1i=12.
Comments/Notices/Holds
Associated PCRs/CVs Original PC# PC 06-35
lns12ection Histor:y
Date Description Act lnsp Comments
06/12/2008 17 Interior Lath/Drywall AP PC
05/21/2008 17 Interior Lath/Drywall PA MC INT DRYWALL ONLY
05/21/2008 18 Exterior Lath/Drywall AP MC
05/21/2008 23 GasfTesURepairs AP MC
05/14/2008 16 Insulation AP MC
05/12/2008 84 Rough Combo AP MC MINOR PICK UP
04/24/2008 13 Shear Panels/HD's AP MC
04/10/2008 15 Roof/Reroof AP MC OK TO DRY IN & LOAD
03/03/2008 11 Fig/Foundation/Piers AP MC RECEIVED SOILS. PT & BLDG SET BACK REPORTS
03/03/2008 12 Steel/Bond Beam AP MC
03/03/2008 21 Underground/Under Floor AP MC
03/03/2008 31 Underground/Conduit-Wiring AP MC CONDUIT ONLY
02/08/2008 21 Underground/Under Floor AP PC
02/08/2008 22 Sewer/Water Service AP PC
m l:ltJOfClrllbld m Flnal Bulldln1 Inspection SEP 2 4 2008
~ ~ Dept: Buildir ngineering Planning CMWD St lite
Plan Check#: 07-62
l Fire
Permit#: CB072427
Project Name: TRIESTE PL 2: PHS 4 2745SF LV,
Date: 09/2312008
Permit Type: RESDNTL
Sub Type: SFD
639SF GAR/11 0SF DECK/138S F LOG/120SF PORCH/103
Address: 2004 PERI DOT CT Lot: 19
Contact Person: Phone:
Sewer Dist: LC Water Dist: CA ..........................................................................................................................................................
Inspected Date cr/2-/05 Approved: _j__ Disapproved: __ By: Inspected:
Inspected Date
By: Inspected: Approved: Disapproved: __
Inspected Date
By: Inspected: Approved: Disapproved: __ ...........................................................................................................................................................
Comments: -------------------------------
"\
Southern California Soil and Testing, Inc.
6280 Riverdale Street, San Diego, CA 92120 (619) 280-4321
P.O. Box 600627, San Diego, CA 92160-0627
83-740 Citrus Avenue, Suite G, Indio, CA 92201-3438 (760)775-5983
Concrete ( 4x8) Compressive Strength Test Report
File Number: 0612215
Project Title: Trieste at La Costa Greens PTCC Phase: 4
Project Location: Court:
Architect: William Hezmalhalch l,~ O 1"2-4 -z,""7
Engineer: Davidson PT Permit No: GBIIT t453
Contractor: Warmington Homes
Location In Structure: Lot: 19 Northeast Quad
Material Supplier:
Mix Designation:
Admixture(s):
Time In Mixer:
Air Content:
Superior
875P
n/a
(ASTM C173/C231)
65
Air Temp:
Truck Number:
65 degrees F
224
Samples Made By:
(ASTM C31)
Laboratory Number
Mark On Samples
Date Made
Date Received
Date Tested
Diameter, Inches
Area, Square Inches
Maximum Load, Pounds
Compressive Strength, psi
Age Tested
Required 28 Day Strength, psi
Fracture Type
MJB
0841911
0612215 Lot
19
3/4/2008
3/5/2008
3/14/2008
4.00
12.57
62960
5010
10 Days
4500
Plan File No:
Slump Inches: (ASTM C143)
Unit Weight Plastic/Dry, pcf:
(ASTM C138/CS67)
Concrete Temp: (ASTM C1064)
Ticket Number:
Samples Tested By:
0841912 0841913
3/4/2008 3/4/2008
3/5/2008 3/5/2008
4/1/2008 4/1/2008
4.00 4.00
12.57 12.57
82030 78740
6530 6270
28 Days 28 Days
4500 4500
1 1
5.00
I
82 degrees F
52101
CN
Specimen sampling, transportation and compressive strength testing were perfonned by this agency in accordance with the applicable
ASTM C39 standards. This agency makes no other warranties express or implied.
Fracture Type: 1 -Reasonably well fonned cones on both ends, less than 1 in. of cracking through caps; 2 -Well formed cone on
one end, vertical cracks running through caps,no well defined cone on other end; 3 -Columnar vertical cracking through both ends,
no well fonned cones; 4 -Diagonal fracture with no cracking through ends; 5 -Side fracture at top or bottom (occur commonly with
unbonded caps}; 6 -Similar to type 5 but end of cylinder is pointed.
Distribution: Reviewed By:
(1) City of Carlsbad -Building Inspection Department
(1) Warmington Homes California Gordon T.M. Woodard RCE # 60481
City of Carlsbad Bldg Inspection Request
For: 03/03/2008
Permit# CB072427 Inspector Assignment:
Title: TRIESTE PL 2: PHS 4 2745SF LV,
Description: 639SF GAR/110SF DECK/138SF LOG/120SF PORCH/103SF
PATIO
Type RESDNTL Sub Type: SFD
Job Address:
Suite:
Location:
2004 PERIDOT CT
Lot
APPLICANT WARMINGTON HOMES
19
Owner: WARMINGTON TRIESTE ASSOCIATES L P
Remarks:
Total Time:
CD Description Act Comment
Phone: 7604271926
Inspector:
Requested By: KYLE
Entered By: JANEAN
11 Fig/Foundation/Piers
12 Steel/Bond Beam
x__ v:~£:l vi? @ILh,, er: -tt :su""" ~ e,Ag:'._,
~po~
21 Underground/Under Floor
31 Underground/Conduit-Wiring
-------··-------------------~
Comments/Notices/Holds
Associated PCRs/CVs Original PC# PC 06-35
lnsgection Histor)'
Datu Descript1011 Act lnsp Comments
02108/2008 21 Underground/Under Floor AP PC
02/08/2008 22 Sewer/Water Service AP PC
PLANNING
ENGINEERING
SURVEYING
IRVINE
LOS ANCELES
RIVERSIDE
SAN DIEGO
HUNSAKER
&ASSOCIATES
S A N D I E C 0, I N C
February 11, 2008
ARIZONA City of Carlsbad
Engineering Department
1635 Faraday Avenue
Carlsbad, CA 92008-7314
DAVE HAMMAR
LEX WILLIMAN
ALISA VIALPANDO
DAN SMITH
RAY MARTIN
CHUCK CATER
9707 Waples Street
San Diego, CA 92121
(858) 558-4500 PH
(858) 558-1414 F X
www.HunsakerSD.com
lnfo@HunsakerSD.com
Re: Building Form Setback Certification
La Costa Greens Neighborhood 1.17
Carlsbad Tract 04-09/PUD 04-08A
Drawing No. 429-2C
Lots 18 through 23
Dear City Inspector:
Please be advised the building foundation forms are in conformance with the
precise grading plans as to horizontal and vertical location. The building
setbacks were measured in relation to the property lines and were found to be in
conformance with the approved precise grading plans for this property.
Sincerely,
Daniel P. Smith L.S. 6854
Hunsaker & Associates San Diego, Inc.
GM:kc lo.:\0t0712006\'J1~.doc
wo 0107-268 2111/2008 7:53 AM
'''/, f ,19~ l 't '.·. ' .... ,
o.~ y1V~13'IJ~-• .,. .. , _ _ ., .. ;: _
S&T'lilL . ' .. •, '.· . '
. '
..
GEOCON
INC O RPO 'R'AT•E,D
6960 FLANDERS DRIVE ■
0 \0 · ~
GEOTECHNICAL CONSULTANTS ~~~
SAN DIEGO, CALIFORNIA 92121-297 4 ■ TEL 1858) 558-6900 ■ FAX (858) 558-6159 .,
FOUNDATION OBSERVATION REPORT
PROJECT NAME : T,-, L Gr.1= • .....,s -W.aQ,.,V) , ,-.,6 n;;,,,-.._; I · 11 PROJECT NO. 06' f?s--sz. -2..4,
DA TE : _...,1--=-i/'-.z...,_~"',._z ...,_/..,,.o"---'-'S1'-------
FOUNDATION LOCATION ('f n t fr b ·1d· I 0 en I e UI rng '-e n I 8 f h ,, ,d 7. L
PLAN FILE NO. PERMIT NOS: ,c, t.....BJ 7 2--'-/-2. '2
l'i 72-'-r27 D ADDITIONAL OBSERVATION REQUIRED
FOUNDATION TYPE : 2..0 : 7l.'f3b
~BST ANTIAL CONFORMANCE D CONVENTIONAL 7_,
0 POST-TENSIONED , z_ -+ 2 ."'S'
• PUR!?,OSE OF OBSERVATION
[]/verify soil conditions exposed are similar to those anticipated
~rify footing excavations extend to minimum depth recommended in soil report
D Verify foundation reinforcement complies with minimum recommended in soil report
D ~ slab reinforcement, sand bedding and moisture barrier comply with
!Sl"'verify footings have been extended to an appropriate bearing strata
D Other
minimum recommended in soil report
• APPLICABLE SOIL REPORT : TITLE : <,J p ..c;;,.t, n c.,, ,.;:·, 'n::o~ t,:}t'' I) V, ~ Cl F /...,AL C) TAJ G e EEc,,l~
/. 11 DATE : s./J c., /00
• ~OIL. EPORT RECOMMENDATIONS BASED ON:
/. "'i -l-Cl Expansion Condition Q VERY LOW Q--'tow
ffFill Geometry C-..., r · Le, r -1 S ;1 v:.jr::, ,.,.. I 9 -LO
0 MEDIUM
D Other : e,,.. :Z = 2 Gi " ( 1 8 ) C,.J r rrr:. /..-f :.. 2 c.. · ·
0 HIGH 0 VERY HIGH
( .........
• M~IMUM FOUNDATION RECO~ENDATIONS:
!1" Footing Depth : ~12 1~c~es lif ~1~ D 24 Inches OTHER _____________ _ Ir' ,;., k. 1J ., _✓.7 .
Footing Reinforcement: D No.4 T&B D 2-No.4 T&B D 2-No.5 T&B w Post-Tensioned OTHER : _____ _
Interior Slab Reinforcement : D 6x6-10/1 0 D 6x6-6/6 D No.3@24Inches D No.3@18Inches Gl'Post-Tensioned
.s .. \ Slab Bedding Material and Thickness : --=-----------Vapor Barrier : v, , '--., , ,-. ,--.,;
Foundation Width : ____ ___,1__.2,__•-'-'-,v1 __ ,--v=---------------------------
• Ol}SERV ATIONS :
of Observation") ~ ~6stantial conformance with Soil Reports (see "Purpose
if Substantial conformance with Foundation Plans. Identify : _...:.1_.,·_r ---' ·_'.__.__. __ . '_· --=-":....:...1 _..::,...,...::....--=-"--' ,._,=--~-'=·:.._"-'"------''--~-=-1':..::"''-'I'--'~:..,~.,_;,_
ti' :Z.. Ou 3:
0 _Q.tb.e
NOTE : IT IS ASSUMED THAT ALL FOOTING EXCAVATIONS Will BE GEANED OF LOOSE MATERIAL PRIOR TO PLACING CONCRETE AND THAT THE SOIL MOISTURE CONTENT WILL BE MAINTAINED
11,,1 /c,_ ;;;:;1,__,,,L __ -lhai: r~;.n-
FIELD COPIES TO GEOCON REPRESENTATIVE