Loading...
HomeMy WebLinkAbout1226 PLUM TREE RD; ; CB971369; Permit... T' r ,. .,.. ..., # . ""' KA FM J:"' • • CITY OF CARLSBA 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB971369 FOR 11/17/97 DESCRIPTION: PLN 2,PHASE 2,2833+636 GAR+56 TYPE: SFD SF PORCH+107 SF DECK,SEASIDE HGHTS,KAUFM JOB ADDRESS: 1226 PLUM TREE APPLICANT: KAUFMAN & BROAD CONTRACTOR: OWNER: REMARKS: C/HAROLD/929-1008 SPECIAL INSTRUCT: TOTAL TIME: RD PHONE: PHONE: PHONE: CD LVL DESCRIPTION ACT COMMENTS 19 ST Final Structural 29 PL Final Plumbing 39 EL Final Electrical 49 ME Final Mechanical -------------------------------------------------------- ***** INSPECTION HISTORY ***** DATE DESCRIPTION ACT INSP COMMENTS 110697 Final Combo NR PD INSPECTOR AREA PD PLANCK# ORIG 970 OCC GRP CONSTR. TYPE VN LOT: 126 102497 Final Electrical AP PD ELEC METER REL 092497 Exterior Lath/Drywall AP PD 092497 Interior Lath/Drywall AP PD 092497 Gas/Test/Repairs AP PD 091997 Rough Combo AP PD 090497 Roof Sheathing/Ext Shear AP PD 090397 Shear Panels/HD's NS PD 082597 Roof Sheathing/Ext Shear NR PD 071797 Ftg/Foundation/Piers AP PD 070897 Underground/Under Floor AP PD 070797 Underground/Under Floor AP PD ,=.--c,,,fINAL BUILDING INSPECTION ~,,,,,--""" ' DEPT: BUILDING ~ FIRE PLANNING U/M WATER PLAN CHECK#: CB971369 DATE: 11/06/97 PERMIT#: CB971369 PERMIT TYPE: SFD PROJECT NAME: PLN 2,PHASE 2,2833+636 GAR+56 SF PORCH+107 SF DECK,SEASIDE HGHTS,KAUFM ADDRESS: 1226 PLUM TREE RD LOT# 126 CONTACT PERSON/PHONE#• C/HAROLD/929-1008 SEWER DIST: CA WATER DIST: CA ~~~P_E__._.::__lt-b-;:;.+~-=-=_===~!~!::::::=,,(1,:;;;~==:::::::=_7_ ::::::::::=_==_== INSPECTED BY: INSPECTED BY: DATE INSPECTED: DATE INSPECTED: APPROVED DISAPPROVED APPROVED DISAPPROVED ============================================================================ COMMENTS: FINA~~ING INSPECTION DEPT: BUILDING ENGINEERING~ PLANNING U/M WATER PLAN CHECK#: CB971369 DATE: 11/06/97 PERMIT#: CB971369 PERMIT TYPE: SFD PROJECT NAME: PLN 2,PHASE 2,2833+636 GAR+56 SF PORCH+l07 SF DECK,SEASIDE HGHTS,KAUFM ADDRESS: 1226 PLUM TREE RD LOT# 126 CONTACT PERSON/PHONE#: C/HAROLD/929-1008 SEWER DIST: CA WATER DIST: CA ============================================================================= INSPECTED DATE BY: {¾ INSPECTED: J!..1-il APPROVED~ DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED =======================================================================~===== COMMENTS: FINAL BUILD~CTION CEPT: BUILDING ENGINEERING FIRE (~ U/M PLAN CHECK#: CB971369 PERMIT#: CB971369 PROJECT NAME: PLN 2,PHASE 2,2833+636 GAR+56 SF PORCH+l07 SF DECK,SEASIDE HGHTS,KAUFM ADDRESS: 1226 PLUM TREE RD LOT# 126 CONTACT PERSON/PHONE#: C/HAROLD/929-1008 SEWER DIST: CA WATER DIST: CA WATER DATE: 11/06/97 PERMIT TYPE: SFD --------------------------------------======-----------=================== INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED ===========================================================================~= COMMENTS: C C--------------- DEPT: BUILDING FINAL BUILDING INSPEC~ ENGINEERING FIRE PLANNING G)M WATER PLAN CHECK#: CB971369 DATE: 11/06/97 PERMIT#: CB971369 PERMIT TYPE: SFD PROJECT NAME: PLN 2,PHASE 2,2833+636 GAR+56 SF PORCH+l07 SF DECK,SEASIDE HGHTS,KAUFM ADDRESS: 1226 PLUM TREE RD LOT# 126 CONTACT PERSON/PHONE#: C/HAROLD/929-1008 SEWER DIST: CA WATER DIST: CA NOV -61997 INSPECTED =========~ BY: ~ SPECTED: ,r4.af/1.PPROVED ~DISAPPROVED_ INSPECTED BY: INSPECTED BY: DATE INSPECTED: DATE INSPECTED: APPROVED DISAPPROVED APPROVED DISAPPROVED ============================================================================= COMMENTS: FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING FIRE PLANNING U/M PLAN CHECK#: CB971369 DATE: 11/06/97 PERMIT#: CB971369 PERMIT TYPE: SFD PROJECT NAME: PLN 2,PHASE 2,2833+636 GAR+56 SF PORCH+107 . SF DECK,SEASIDE HGHTS,KAUFM ADDRESS: 1226 PLUM TREE RD LOT# 126 CONTACT PERSON/PHONE#: C/HAROLD/929-1008 SEWER DIST: CA WATER DIST: CA INSPECTED BY: ... DATE INSPECTED: DATE INSPECTED: APPROVED APPROVED \J b DISAPPROVED DISAPPROVED =========================================================================~ == COMMENTS: SOUTHERN CALIFORNIA SOIL AND TESTING, INC. 6280 RIVERDALE STREET, P. 0. Box 600627, SAN DIEGO, CA 92160 (619) 280-4321 Concrete Compressive Strength Test Report File Number: Project Title: Project Location: Architect: Engineer: Contractor: 9712187 Collections -Sambi 1226 Plum Tree Road Kaufman & Broad JLD Kaufman & Broad Location In Structure: Material Supplier: Lot 126 -N. E. Quad Post-Tension Slab-on-Grade Superior Ready Mix Mix Designation: Admixture(s): Time In Mixer (Minutes): Truck Number: Samples Fabricated By: Laboratory Number: Mark: Date Made: Date Received Date Tested Diameter, Inches Area, Square Inches Maximum Load, psi Compressive Strength, psi Age Tested, Days 35P 606 JB Required 28 Day Strength, psi Unit Weight, pcf 9716 07-21-97 07-22-97 07-31-97 6.00 28.27 62,500 2,210 10 2,500 Slump, Inches.· 4-112 Ticket Number: 146100 Samples Tested By: JWB 9717 9718 08-18-97 08-18-97 92,000 114,000 3,250 4,030 28 28 Permit No: 971-369 Plan File No: CC Temp. A,r Temp: Air Content: 0 0 Specimen sampling, transportation and compressive strength testing were performed by this agency in accordance with the applicable ASTM standards. This agency makes no other warranties express or implied. Distribution: (3) Kaufman & Broad ( 1) Superior Ready Mix (1) City of Carlsbad 07-21a 8/19197 Reviewed By: George Gavit, RCE #56564