Loading...
HomeMy WebLinkAbout1890 RUTHERFORD RD; ; CB013369; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 11-21-2601 Commercial/Industrial Permit Permit No: CB013369 Building Inspection Request Line (760) 602-2725 Job Address: 1890 RUTHERFORD RD CBAD Permit Type: TI Sub Type: INDUST Parcel No: 2121203500 Lot #: 0 Status: ISSUED Valuation: $2,000.00 Construction Type: NEW Applied: 10/24/2001 Occupancy Group: Reference #: Entered By: JM Project Title: BREEZECOM - RELOCATE EXIST Plan Approved: 11/21/2001 PALLET RACKS Applicant: HOLLLINGSWORTH RUSS 6221 YARROW DRIVE CARLSBAD CA 92008 760-931-5456 Issued: 11/21/2001 Inspect Ar87 11/21/01 0002 01 02 Owner: COP 38.91 DIVERSIFIED CARLSBAD 47&48 L L C 4330 LA JOLLA VILLAGE DR #110 SAN DIEGO CA 92122 Total Fees: $63.91 Total Payments To Date: $25.00 Balance Due: $38.91 Building Permit $38.13 Meter Size Add'I Building Permit Fee $0.00 Add'I Red. Water Con. Fee $0.00 Plan Check $24.78 Meter Fee $0.00 Add'I Plan Check Fee $0.00 SDCWA Fee $0.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $1.00 PFF $0.00 Park Fee $0.00 PFF (CFD Fund) $0.00 LFM Fee $0.00 License Tax $0.00 Bridge Fee $0.00 License Tax (CFD Fund) $0.00 BTD #2 Fee $0.00 Traffic Impact Fee $0.00 BTD #3 Fee $0.00 Traffic Impact (CFD Fund) $0.00 Renewal Fee $0.00 PLUMBING TOTAL $0.00 Add'I Renewal Fee $0.00 ELECTRICAL TOTAL $0.00 Other Building Fee $0.00 MECHANICAL TOTAL $0.00 Pot. Water Con. Fee $0.00 Master Drainage Fee $0.00 Meter Size Sewer Fee $0.00 Add'I Pot. Water Con. Fee $0.00 Redev Parking Fee $0.00 Red. Water Con. Fee $0.00 Additional Fees $0.00 TOTAL PERMIT FEES $63.91 FINAL PPR VAL Inspecto? Date: 9,1Z - - Clearance: NOTICE: Please take NOTIC that approval of your project includes the'Imposition" of fees, dedications, reservations, or other exactions hereafter collechvely. referred to as 'lees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. FOR OFFICE USE ONL PLAN CHECK NO._________ EST. VAL. ___________________ ..J. Plan Ck. DepoJI. ValidatedBv...JV1&. PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 Address (include Bldg/Suite #) /7q 74'a iE.b Business Name (at this address) Legal DescriPti ,r. '.5 2. Lot No, Subdivision Name/Number Unit No. i./ Phase No. Total,# of units Assessor's Parcel 1q ,. ? "Is / ( pxin)e 9fc/2o 2rsLiO1 25-00 Description of Work SQ. FT. # tori # of Bed6o'ms # Bathrooms LC0NTACTPERS0 . tcomi :._ Name (4 55 ó'I-/ 4.4 Cit(4 State/Zip Telephone #f3/ Fax # 3 APPUCANT OcLi Name " Address - City, ft State/Zip. Telephone '# IJ(_.a-JV F4(1 -, -v :Name L/ Address City State/Zip Telephone # (Soc. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's Licinse Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Pqpfessions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violati of Section 7031 .5 by any applicant fpry,permit subjects not moan five huridmd,,dollars_i$500lL '- Name . AdoTess City State/Zip Telephone # State License # 3 q y S License Class C .( City. Business License # Designer Name Address City State/Zip Telephone State License # COMPENSATION Workers' Compensation Declaration: -I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. - I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Cpany Policy No. Expiration Date__________________ (THl..Sfil0N NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($1001 OR LESS) .' CERTIFICAT EXEMPTION: I certify that in the performanc of the work for which this permit is issued,i shall notemploy any person in any manner so as to become subje to he Workers' Compensation Laws of Californi - - WARNING: Fa ure secure wor e • comp nsatlon coverage unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dolls ($1 0.000). in a d i n to h of comp ion, damages as provided for In Section 3706 of the Laloude. interest and attorney's fees. SIGNATURE DATE OWNER ÔiARAWO TT .TT 777,71. 7 I hereby affirm that I am exempt from the ontractor s License Law for the following reason I, as owner of the property or my ployees with wages as their sole compensation; will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who.does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale)... 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 I am exempt under Section Business and Professions Code for this reason: I personally plan to provide the major labor and materialà for construction of the proposed property improvement. 0 YES ONO I (have / have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name / address I phone number / contractors license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address / phone number I contractors license number): I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address I phone number / type of work): PROPERTY OWNER SIGNATURE DATE____________________ ___ Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevehtioñ program under Sections 25.505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? . 0 YES NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? , 0 YES . NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UfiLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 8 ICONSTRUCTION LENDING AGENCY1J .,---- '! Ta - I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 30970) Civil Code) LENDER'S NAME LENDER'S ADDRESS E~7 77 r. 71177 I certify that I have read ,the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of -Carlsbad, to enter upon the, above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMVSS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTSAND EXPENSES ANY WAY ACCRUE AGAINST SAID CITY CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is re id for excavations ov r 5'0" deep d demolition or constru on of structures over 3 stories in height. EXPIRATION: Every per issued by the luildin icial und pro isio of this Co shall.expire by limitation and become null and void if the building or work authorized by such perm is not commenc n 180 days fr e - e of uch perm if the building or work authorized by such permit is suspended or abandoned at any time after the wo is commenced a period of 18 y (S ion 10 4.4 U or Building Code).' APPLICANT'S SIGNAT RE 1 ' - '" DATE - WHIT - File YELLOW: Applicant PINK: Finance - - City of Carlsbad Bldg Inspection Request W)r7, For: 11/29/2001 jk-i 1.91 Permit# CB013369 Inspector Assignment: Title: BREEZECOM - RELOCATE EXIST Description: PALLET RACKS Type: TI Sub Type: INDUST Phone: 6195404516 Job Address: 1890 RUTHERFORD RD Suite: Lot 0 Location: Inspector: APPLICANT HOLLLINGSWORTH RUSS Owner: DIVERSIFIED CARLSBAD 47&48 L L C Remarks: FINAL ON PALLET RACK INSTALLATION Total Time: Requested By: RUSS ' t c. Entered By:' KAREN CD Description Act , Comments1 19 Final Structural rT Associated PCRs PCR99208 ISSUED PCR99239 ISSUED - - Inspection History Phooc,' Date Description ...-Act Insp Comments !isp : • qtci y Ri E!terec p3',' K. _,)' ?r'' EsGil Corporation 1n Partnership with gove rnment for Wui&(ing Safety DATE: 11/20/01 JURISDICTION: Carlsbad PLAN CHECK NO.: 01-3369 PROJECT ADDRESS: 1890 Rutherford #100 SET: II OAPPLICANT JURIS. Cr-PrgN-- REVIEWER 0 FILE PROJECT NAME: Storage Racks for Breezecorn D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. Eli The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. . The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. fl Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person REMARKS: 1. City to field verify that the pk'o travel from the handicapped parking space to the rack area and the bathrooms serving rack area comply with all the current disabled. access requirements. 2. Fire departmeif approval is required. By: David Yao Enclosures: Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 11/13 trnsmtl.dot 9320 chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation 2n Partnership with government for Bui(1ing Safety DATE: 11/2/01 JURISDICTION: Carlsbad PLAN CHECK NO.: 01-3369 SET: I PROJECT ADDRESS: 1890 Rutherford #100 PROJECT NAME: Storage Racks for Breezecom O APP. IANT JC JURI EVIEWER O FILE The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. Li The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Russ Hollingsworth 6221 Yarrow Dr., Carlsbad, CA zoo Li Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Russ Hollingsworth Telephone #: (760)931-5456 (hoc) Date contacted: 111510' (by:(i.,c) Fax #: (760)931-5466 Mail -Ttephone Fax .-- In Person Li REMARKS: By: David Yao Enclosures: Esgil Corporation E GA D MB E EJ Ij Pc 10/25 trnsmtl.dot 9320 Chespeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858)560-1576 Carlsbad 01-3369 11/2/01 GENERAL PLAN CORRECTION LIST JURISDICTION: Carlsbad PLAN CHECK NO.: 01-3369 PROJECT ADDRESS: 1890 Rutherford #100 DATE PLAN RECEIVED BY DATE REVIEW COMPLETED: ESGIL CORPORATION: 10/25 11/2/01 REVIEWED BY: David Yao FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. Carlsbad 01-3369 11/2/01 Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from-this list?. El Yes El No Carlsbad 01-3369 11/2/01 Only the storage racks are included in this plan review Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24. Provide a note on the plans indicating if any hazardous materials will be stored and/or used within the building which exceed the quantities listed in UBC Tables 3-D and 3-E. City to field verify that the path of travel from the handicapped parking space to the rack area and the bathrooms serving the rack area comply with all the current disabled access requirements. Obtain Fire Department approval for groups F, M and S occupancy storage per UBC Sections 306.8, 309.8 and 311.8. Note on the plans that the rack design loads will be posted per Section 2222.5. Indicate the clearance from the new racks to the existing building walls and building columns. Provide forklift protection per Section 2222.5.(or check the exception or note on the plan that no forklift will be used.) Recheck the "pallet" racks as follows: Recheck all connections on sheet I as follows: The rivet bearing capacity is only dtF = 0.406(0.0747)65 = 2 kips. Provide calculations for all beam to bracket weld capacities per Section 2330 (allowable weld stress is the member thickness times 26 ksi times 1.33, or the weld stress, whichever is lower). Check the bracket maximum weak axis moment. Indicate the safety pin size and verify it is adequate for the 1000# load. Provide calculations for the column weak axis bending plus axial for transverse seismic loading. The axial load is the maximum compression load at the base from vertical plus seismic overturning. The column moment will probably be maximum for the lateral load from the base plate to the first diagonal brace (not only to the first horizontal member). Check the slab stress for the maximum transverse overturning axial load. Show the slab thickness on the plans per the calculations. Check the maximum slab stress under the base plate per Section 1915.4.2. The thickness of the beam is not shown on the plan.(.0747 in) Please clarify. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact David Yao at Esgil Corporation. Thank you. Carlsbad 01-3369 1112/01 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 01-3369 PREPARED BY: David Yao DATE: 11/2/01 BUILDING ADDRESS: 1890 Rutherford #100 BUILDING OCCUPANCY: TYPE OF CONSTRUCTION: BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) storage racks per city 2,000 Air Conditioning FireSprinklers I TOTAL VALUE 2,000 Jurisdiction Code Icb IBY Ordinance I ___ 1994 UBC Building Permit Fee IV] I $38.13 I 1994 UBC Plan Check Fee V I $24.781 Type of Review: I Complete Review J Structural Only O Other 0 Repetitive Fee I i Repeats Hourly I Hour * Esgil Plan Review Fee I $21.35! Comments: Sheet 1 of .1 macvalue.doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB QE 3C1 DATE__ og kf ___________ ADDRESS. 100. RESIDENTIAL TENANTIMPROVEMEN RESIDENTIAL-ADDITION MINOR PLAZACAMINO REAL (<$10,000.00) CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER •LS . PLANNER Qmlo DATE 101j.q foi ENGINEER 1 DATE Docs/Misforms/plannlng Engineering Approvals Cajjsoad Fire Department 013369 1635 Faraday Ave. Fire Prevention Carlsbad, CA792008 (760) 602-4660 Plan Review Requirements Category: tBuildii*P1an1J Date of Report: 11/13/2001 1 Reviewed by: &. i'nI— Name: Russ Hollingsworth Address: 6221 Yarrow Drive City, State: Carlsbad CA 92008 Plan Checker: Job #: 013369 Job Name: Breeze.com #100 Bldg #: CB013369 Job Address: 1890 Rutherford Rd Ste. or Bldg. No. 100 Z Approved The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicablecodes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. II Approved The item you have submitted for review has been approved subject to the Subject to attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. U Incomplete The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. Review 1St __________ 2nd __________ 3rd __________ Other Agency ID FD Job # 013369 FD File # 7 Updated Geotechnical Investigation Page 16 i' Proposed Concrete Tilt-up Structure Lots 47 and 48, Carlsbad Research Center, Carlsbad, California September 26, 1996 CTE Project No. 10-1874 The maximum total settlement is expected to be on the order of 1.0 inch. The maximum differential settlement of continuous footings across the building is expected to be on the order of 0.5 inch. . 0=0 4TWIMIRMIT7 In all cases, footings for structures should be designed such that the horizontal distance from the top of the adjacent slope to the outer edge of the footing is a minimum of 10 feet. ME (4ti RS]tTT -Concrete slabs-on-grade should be at least four inches thick for light industrial loads. As a minimum, concrete slabs should be reinforced with #3 reinforcing bars on 18-inch or #4 reinforcing bars on 24-inch centers. All slab reinforcement should be properly supported to ensure placement near mid-height of the concrete. Special design consideration should be given to the type of business and the building's intended use. Heavy machinery or vehicular loads may require aggregate base, thicker slab and increased reinforcement. This office should be contacted provide additional recommendations if conditions differ from those assumed above. In moisture sensitive floor areas, slabs should be underlain by a vapor barrier consisting of a minimum of six mil polyethylene sheeting or equivalent membrane with all laps 5' PUN. bLA MADE P41 ,.1roIcPL WAY cENIER OF LA8 PLACE 3LAB IVER 2' SAW OVER 6 ML VAPORBAFRER OVER 4=1NAl rer4øPl rNBPEcT"' ' NOT FREEMM .1 'I vi.0 - uu-ii vI.uurlyi rKvIyruIvIIIrpci) rnurcmica uouot 14ou r.uuug r4 • ICOL. cOL COL. 3281- - 11 400 40•-ØI' 40ç00 • TYP. ¶ iJT I . 3 * l/ 4r,L-. F33 I/I : 22-10 1/2' IME F 7'Updated Geotechnical Investigation Page 17 / Proposed Concrete Tilt-up Structure J' Lots 47 and 48, Carlsbad Research Center, Carlsbad, California Yt September 26, 1996 CTE Project No. 10-1874 sealed. This membrane should be placed over two inches of clean sand (Sand Equivalent > 30) and covered with a minimum of two inches of sand to protect the sheeting during concrete placement operations. Lateral loads acting against structures may be resisted by friction between the footings and the supporting soil or passive pressure acting against structure. If frictional resistance is used, we recommend allowable coefficients of friction of 0.35 (total frictional resistance equals coefficient of friction times the dead load) for concrete cast directly against compacted fill. A design passive resistance value of 300 pounds per square foot per foot of depth (with a maximum value of 1200 pounds per square foot) may be used. This value assumes a horizontal soil extending at least 10 feet. The allowable lateral resistance can be taken as the sum of the frictional resistance and the passive resistance, provided the passive resistance does not exceed two-thirds of the total allowable resistance. Retaining walls up to ten feet high band backfilled using granular import soils may be designed using the equivalent fluid weights given in Table 3 below. LAKLSbAD, LA. #01-1776 SE1ZM1C MATERIAL HANDLING ENGINEERING EST. 1985 STORAGE RACKS STEEL SHELVING CITY APPROVALS - ALASKA NEVADA DRIVE-IN RACKS MOVABLE SHELVING STATE APPROVALS ARIZONA NEW MEXICO CANTILEVER RACKS STORAGE TANKS PERMITTING SERVICES CALIFORNIA OREGON MEZZANINES MODULAROFFTCES PRODUCTTESTING COLORADO PENNSYLVANIA CONVEYORS GONDOLAS RELD INSPECIlON IDAHO IJAH CAROUSELS BOOKSTACKS SPECIAL FABRICA11ON MISSOURI WASHINGTON 161 ATLANTIC STREET • POMONA • CA 91768 S TEL: (909)869-0989 9 FAX: (909)869-0981 r SEI l7mlr~- Zmic MATERIAL HANDLING ENGINEERING EST. 1985 TEL: (909) 869-0989 FAX: (909) 869-0989 STRUCTURAL CORRECTION FOR- BREEZE COM 5858 EDISON PLACE CARLSBAD, CA. 01-1776 DATE: 11-08-01 BELOW ARE THE RESPONSES TO YOUR PLAN CORRECTION SHEET: 6. PLEASE SEE ADDED NOTE ON DETAIL DRAWING 01-1776A, WHERE POST LOAD HAS BEEN ADDED PER SECTION 2222.5 OF THE 1997 UBC. PLEASE SEE REVISED CALCULATIONS WHERE COLUMNS HAVE BEEN CHECKED WITHOUT THE USE OF POST PROTECTORS PER SECTION 2222.5 OF THE 1997 UBC. NOTE SYSTEM IS ADEQUATE FOR IMPOSED LOADS. (PAGE 9B) PLEASE SEE REVISED CALCULATIONS WHERE BEAM TO COLUMN CONNECTION HAS BEEN REVISED (PAGE 11). PLEASE SEE REVISED CALCULATIONS WHERE BEAMTO BRACKET WELD CAPACITY HAS BEEN CHECKED FOR ADEQUACY. PLEASE SEE REVISED CALCULATIONS WHERE BEAM TO COLUMN CONNECTION HAS BEEN REVISED (PAGE 11). PLEASE NOTE THAT THE SAFETY PIN HAS ENOUGH CAPACITY TO WITHSTAND THE REQUIRED boot tJPLI-FF -FORCE. 5116" SAFETY -PIN AREA = A*0.4*FY =(0.0767)(0.4)(50000) =1534# >> 1000# PLEASE SEE REVISED CALCULATIONS WHERE COLUMN WEAK AXIS BENDING PLUS AXIAL FOR TRANSVERSE SEISMIC LOADING HAS BEEN CHECKED (PAGES 9C & D). PLEASE SEE CALCULATIONS PAGE 15 WHERE SLAB IS CHECKED FOR MAXIMUM LOAD INCLUDING TRANSVERSE OVERTURNING AXIAL LOAD. PLEASE SEE NOTE #6 ON DETAIL DRAWING 01-1776A WHERE SLAB THICKNESS HAS BEEN SPECIFIED. PLEASE SEE REVISED DETAIL DRAWING 01-1776A WHERE THE BEAM GAGE IN DETAIL #6 HAS BEEN SPECIFIED. (0.0747, 14GA) PLEASE FEEL FREE TO CALL WITH ANY QUESTIONS YOU MAY HAVE REGARDING THE ABOVE MATTERS. fS E flZ M:I C:: MATERIAL HANDLING ENGINEERING TEL: (909)869-0989 9 FAX: (909)869-0981 161 ATLANTIC STREET • POMONA • CA 91768 PROJECT BREEZECOM FOR Cs GOODALE SHEET NO. 2 OF 15 CALCULATED BY_BOBS. DATE- -11092001 TABLEOFCONTENTS DESCRIPTION COVER SHEET TABLE OF CONTENTS SCOPE PARAMETERS CONFIGURATIONS COMPONENTS & SPECS. LOADS AND DISTRIBUTION LONGITUDINAL ANALYSIS COLUMN BEAM BEAM TO COLUMN BRACING OVERTURNING BASE. PLATE SLAB & SOIL PAGE #- 1 2 2 3 . 4-4 5-6 .. 7. 8 9 10 11 12 13 14 15 SCOPE: . .• THIS ANALYSIS OF THE STORAGE SYSTEM IS TO DETERMINE ITS COMPLIANCE WITH THE APPROPRIATE BUILDING CODES WITH RESPECT TO STATIC AND SEISMIC FORCES. THE STORAGE RACKS ARE PREFABRICATED AND ARE TO BE FIELD ASSEMBLED ONLY, WITHOUT ANY FIELD WELDING. C :S!E I 2ZMIC MATERIAL HANDLING ENGINEERING TEL: (909)869-0989 9 FAX: (909)869-0981 161 ATLANTIC STREET • POMONA • CA 91768 PROJECT BREEZECOM . I. FOR Cs GOODALE SHEET NO- 3 15 CALCULATED BY BOBS' DATE 11-09-2001 STORAGE RACKS CONSIST OF SEVERAL BAYS, INTERCONNECTED IN ONE OR BOTH DIRECTIONS WITH THE COLUMNS OF THE VERTICAL FRAMES BEING COMMON BETWEEN ANY ADJACENT BAYS. THE ANALYSIS WILL FOCUS ON A TRIBUTARY BAY TO BE ANALYZED IN BOTH LONGITUDINAL AND TRANSVERSE DIRECTION. STABILITY LONGITUDINALLY IS DEPENDANT ON BEAM TO COLUMN MOMENT, WHILE THE BRACING ACT TRANSVERSELY. COLUMN. BEAM. BEAM TO--COLUMN. BASE PLATE. HORIZONTAL BRACING. DIAGONAL BRACING. BACK CONNECTOR. TRIBUTARY AREA r7. TRANSVERSE LONGITUDINAL TOP VIEW 108" r::S:H~ZMIC MATERIAL HANDLING ENGINEERING TEL: (909)869-0989 • FAX: (909)869-0981 161 ATLANTIC STREET • POMONA • CA 91768 CONFIGURATIONS PROJECT BREEZECOM FOR CS GOODALE SHEETNO.OF 15 CALCULATED BY BOB S. DATE 11-09-2001 TYPE 1-SIR 2.200 lb. TYPE 1-D/R MATERIAL HANDLING ENGINEERING TEL: (909)869-0989 9 FAX: (909)869-0981 161 ATLANTIC STREET • POMONA • CA 91768 PROJECT BREEZECOM FOR ••CS GOODALE SHEET NO.______________ OF 15 CALCULATED BY BOB S. DATF 09200 1 TYPE 1-SIR SPECIFICATION '1 48" - MAIN STEEL 50000 PSI - BASE PLATh STEEL 36000 PSI - ANCHOR -. WEDGE TYPE 1/2 x 3-1/2 4311 - FLOOR SLAB 5" X 4000 PSI. REINFORCED 192" - SOIL BEARING PRESSURE 1.000 PSF . - SEISMIC ZONE 4. - TYPE = SINGLE ROW UNITS. T.. 511# 651# lb. lb. 383 6p" 10 255# 6" 10 127 6L — 325# —ø 162# -0 I '1' 10811___'1' Iu= 108" 42" SECTION AXIAL FORCE MOMENT BEAM MOMENT 1 4,5.60.1b. 18,921 in. b.. 18370 in-lb. -stdconn. 2 3,420 lb. 13,820 in.lb. 14,284 in.lb. <-std.conn. 3 2,280 lb. 10,749 in.lb. 10,445 in.lb. <-std.conn. 4 1,14OIb. 6,142 in.lb. 5,071 in.lb. <-std.conn. TYPE 1-S/R DESIGN LOAD =2200# BASEPLATE COLUMN BEAM V 3X3X1 2GA: 8 X 5 X.375 COLUMN STRESS =0.77 4-3/1 6X2-1 /2X1 4GA(BB3) Mbase = 10509 in.lb. MAX LOAD/LEVEL 4,421 lb. BEAM IS O.K. OVERTURNING BRACING SLAB&SOIL HORIZONTAL 41 DIAGONAL . ANCHOR STRESS = 0.80 1 1/2 X 1/2 X 16 GA I 1 1/2 X 1/2 X 16 GA PUNCT. STRESS = 0.76 # OF ANCHORS = 2 STRESS =0.27 (_ STRESS =0.94 BENDING STRESS =0.99 451# MIC MATERIAL HANDLING ENGINEERING TEL: (909)869-0989 9 FAX: (909)869-0981 161 ATLANTIC STREET. POMONA • CA 91768 PROJEC BREEZECOM T_______________ Cs G000ALE SHEET NO 6 OF_15 CALCULATED BY_ BOB S. DATE 11-09-2001 TYPE _1-DIR SPECIFICATION 1' 48" - MAIN STEEL 50000 PSI - BASE PLATE STEEL 36000 PSI - ANCHOR - WEDGE TYPE 1/2 x 3-1/2 43" - FLOOR SLAB 5" X 4000 PSI. REINFORCED 192" - SOIL BEARING PRESSURE 1000 PSF 48" - SEISMIC ZONE 4. I - TYPE = INTERCONNECTED UNITS. 3,000 1b. 88# 6[_ 0" 0 lb. 35 lb. I1266irr 6P" lb. Ill 77:9 j;_,ii u_u_ii A' 108" A' A' 42"4 Iu= 108" SECTION AXIAL FORCE MOMENT BEAM MOMENT 1 6,160 lb. 12,580 in.Ib. 13-078 in:Ib. <-std.conn-. .2 4,620 lb. 9,577 iiilb. 10,513 in.Ib. <-std.conn. 3 3,080 lb. 7,449 in.lb. 7,852 in.Ib. <-std.conn. 4 1,540 lb. 4,256 in.Ib. 4,128 in.lb. <-std.conn. TYPE 1-D/R DESIGN LOAD =3000# BASEPLATE COLUMN BEAM 3X3X1 2GA. -sf 8 X 5 X.375 COLUMN STRESS =0.66 4-3/1 6X2-1/2X1 4GA(BB3.) . Mbase = 7814 in.Ib. MAX LOAD/LEVEL= 4,421 lb. BEAM IS O.K. OVERTURNING BRACING SLAB&SOIL HORIZONTAL / I DIAGONAL . . . •sJ. ANCHOR STRESS = 0.12 1 1/2 X 1 1/2 X 16 GA I 1 1/2X1 1/2 X 16 GA PUNCT. STRESS =0.71 # OF ANCHORS = 2 STRESS = 0.19 STRESS = 0.65 BENDING STRESS =0.91 r:=SElZM1C MATERIAL HANDLING ENGINEERING TEL: (909)869-0989 • FAX: (909)869-0981 161 ATLANTIC STREET • POMONA • CA 91768 PROJECT BREEZECOM • FOR CS GOODALE SHEET NO.______________ OF 15 CALCULATED BY BOB 5. DATE__ -09-200 1 LIVE LOAD PER SHELF = Wil = 2,200 lb (BASED ON CLIENT SUPPLIED DATA) DEAD LOAD PER SHELF = WdI = 80 lb Seismic Zone = 4 1= 1 TOTAL LOAD PER FRAME= 9,120 lb SEISMIC SHEAR BASED ON SECTION 1630.2.1 OF THE 1997 UBC WHERE V= ((2.5xCaxI)/R)xWtotal Wtotal = (Wil + WdI) x n n = # of shelves 2,200 lb. 511 4 2.200 lb. 38 lb. 255# lb. 127# Ca = 0.44 R(long) = 5.6 R(trans) = 4.4 Soil Coef. = Sd Na= .1.0 Nv= 1.6 U 108" I u = 108" 6.51# Viong = (2.5 x 0.44 x 1)I(5.6)x W) / 1.4 . 011 / = 1280 lb wl working stress reduction 10 10 T62# - Vtrans = (2.5x 0.44 x 1)1(4.4) x W/ 1.4 = 1629 lb w/ working, stress reduction Fi= VWhi/Wh 488# Fi= VWhiIWh I TRANSVERSE DIRECTION 32 5# -, 000 :MIc MATERIAL HAN DUNG ENGINEERING TEL: (909)8.69-0989 9 FAX: (909)869-0981 PROJECT BREEZECOM FOR CSGOODALE SHEET NO— 8 OF 15 CALCULATED BY_BOB S. DATE_-09-2001 ibi Al LAN II SlKtI • FUMUNA ' LA V1(b5 LONGITUDINAL ANALYSIS :TYPE 1-SIR THE ANALYSIS IS BASED ON THE PORTAL METHOD, WITH THE POINT OF CONTRA FLEXURE OF THE COLUMNS ASSUMED AT MID-HEIGHT BETWEEN BEAMS, EXCEPT FOR THE.LO WEST PORTION, WHERE THE BASE PLATE PROVIDES ONLY PARTIAL FIXITY, THE CONTRA FLEXURE IS ASSUMED TO OCCUR CLOSER TO THE BASE.(OR AT THE BASE FOR PINNED CONDITION, WHERE THE BASE PLATE CANNOT CARRY MOMENT). Vlong = 2 * Vcol = 1,280 lb. Vcol= 640 lb. . 1' 48in Blflto F 1 = 64 lb. CoLoniL F2= 1281b. . Fl ( 5" F3= 1921b. . I I 48 in .....r h= 461n. CoL to slab. F4= 2561b. BASE PROVIDE PARTIAL. FIXITY. SEE.. BASE. PLATE .SHT. Mbase = 10509 in.Ib. I Mupper Mupper + Mlower = McQnn'R' + Mconn'L' . .. Mconn'R' = Mconn'L' Mconn *2=Mupper +Mlower . R nu o Me Mconn = [Mupper + Mlower]/2 MIower._J-JI RESULTINGFORCESONCOLUMN SECTION AXIALLOAD MOMENT Mconn 1 4560 18921 4SL.AB 18370 2 . 3420 13819 14284 3 2280 10748 10445 4 1140 6142 hA _ d,I ] —.kc SECTION PROPERTIES A= 311 B =3" C= 75" 0= 0" E=0" wt. =0# tl =.1046" t2=0" Area =.B15"A2 Ix = 1.65"A4 Iy = 1.1"A4 Sx = 1.21TA3 Sy = 73"A3 rx = 1.304" ry = 1.08" 60" + 60" Front View Side View MATERIAL HANDLING ENGINEERING TEL: (909)869-0989 • FAX: (909)869-0981 161 ATLANTIC STREET • POMONA • CA 91768 PROJECT BREEZECOM FOR £S GOODALE SHEET NO 91 OF 15 CALCULATED BY BOB S. DATE 11-09-2001 COLUMN ANALYSIS :TYPE 1 -SiR COLUMN IS ANALYZED PER AISI COLD-FORMED STEEL DESIGN MANUAL fa = Pmax/Area = 4,984 psi. fb =Mmax/Sx = 15,768 psi. fa/Fa =0.21 >15 F'e = 1 2w2E/23(Kxlxtrx.)A2 Fe = 83,335 psi. Fb = .6*Fy = 30,000 psi. Cm*fb/Fb[1fa/Fe] = 0.56 COMBINED 'STRESS = 0.77 Pmax = 4,560 lb. Mmax = 18,921 in.lb. Kxlx/rx = 1.2 * 46 I 1.304 = 42.3 Kyly/ry = .8 * 60/ 1.08 = 44.4 <-GOVERNS Cc = (21TA2E/Fy)A.5 = 107.0 SINCE KI/r <= Cc, Fa = .522Ey — [(kl/r*Fy)/1 494]A2 =23,888 psi. T MIC MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 • FAX: (909) 869-0981 161 ATLANTIC AVENUE• POMONA • CA 91768 PROJECT BREEZE COM FOR Cs GOODALE SHEET NO. 915 OF 15 CALCULATED BY BOB. S. tt/91Ut COLUMN ANALYSIS (3X3X1 2GA) EXPOSED POST CHECK ANALYZED PER DIV VII, CHAP 22 OF THE 1997 UBC. SECTION PROPERTIES BASED ON THE EFFECTIVE SECTION. P= 4,560 LB M= 0 IN-LB KxLx/rx = 1 2*46 IN/i .304 IN = 42.3 KyLy/ry = 0.8*60 IN/i .08 IN = 44.4 <=== (KI/r)max AXIAL Fe= nA2E/(KL/r)maxA2 = 147.4 KSI Fy/2= 25.0 KSI SINCE, Fe > Fy/2 THEN, . Fn= Fy(1-Fy/4Fe) = 50 KSI*[150 KSI/(4*1 47.4 KSI)] = 45-8. KSI. Pn= Aeff*Fn 41,870 LB (c= 5/3 + (3/8)*R - (1/8)*RA3 = 1.81 Pa= Pn/flc = 41870 LB/1 .&1237446447951 = 23,102 LB P/Pa= 0.20 > 0.15 FLEXURE CHECK: P/Pa + (Cmx*Mx)/(Max*px) :S 1.33 P/Pao + Mx/Max :5 1.33 Pno= Ae*Fy = 0.915 INA2 *50000 PSI = 45,750 LB Pao= Pno/flc = 45750 LB/1 .81237446447951 = 25,243 LB Myield=My= SX*FY = 1.2 INA3 * 50000 PSI = 60,000 IN-LB Max= My/Qf = 60000 IN-LB/1.67 = 35,928 IN-LB Pcr= nA2EI/(KL)maxA2 = 11A2*295Uff KSII(1 .Z*46 IN)A2 = 157,662 LB Thus, (EQ C4. i-l-)- (EQ. C4-3) (EQ C4-2) (EQ C4-1) (EQ CS-1) (EQ C5-2) A= 3.0 IN B= 3.0 IN C= 0.75 IN t = 0.1046 IN Aeff = 0.915 INA2 Ix= 1.SQINt4 Sx= 1.200 INA3 rx= 1.304 IN !y= 1.100INA4 Sy = 0.730 INA3 ry= 1.080 IN Kx=1.2 Lx = 46.0 IN Ky = 0.80 Ly=60.OIN Fy= 50 KSI E= 29,500 KSI flf= 1.67 Cmx= 1.0 Cb= 1.0 px= (1/(i _(Qc*P/Pcr)]}A_1 = {1/1J1-(1.81M560 LB/1 57662 LB)flA-T = 0.95 (4560 LB/23102 LB) + (1*0 IN-LB)/(35928 INLB*0.95) = 0.20 <1.0, OK (EQ C5-1) (4560 LB/25243 LB) + (0 IN-LB/35928 IN-LB) = 0.18 <1.0, OK (EQ C5-2) SINCE COLUMN IS LESS THAN HALF STRESSED, if IS OK FOR •GOE+JSIOttOAD&-(PER SEC -225) [=S=ElZMl=C: MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 • FAX: (909) 869-0981 161 ATLANTIC AVENUE •. POMONA• CA 91768 PROJECT BREEZE COM FOR CS GOODALE SHEET NO. 9C OF 15 CALWLATEDBY BOBS. DATE 11/9101. COLUMN ANALYSIS (3X3X1 2GA) DOWN AISLE LOADS ANALYZED PER DIV VII, CHAP 22 OF THE 1997 UBC. SECTION PROPERTIES BASED ON THE EFFECTIVE SECTION. P= 4,560 LB M= 18,921 IN-LB KxLxlrx = 1.2*46 IN/i .304 IN =42.3 KyLy/ry-= 0860-tN/1-08-IN- = 44.4 <=== (KI/r)max AXIAL Fe= irA2E/(KL/r)maxA2 = 147.4 KSI Fy/2= 25.0 KSI SINCE. Fe->. E-y/2 THEN, Fn= Fy(1-Fy/4Fe) = 50 KSI[1-50 KSI/(4*147.4 KSI)] = 45.8 KSI Pn= Aeff*Fn =41,870LB Qc= 5/3 + (3/8)'R - (1 /8R3 =1.81 Pa= Pn/flc = 41870 LB/1 .81237446447951 = 23,102 LB P/Pa= 0.20 > 0.15 FLEXURE CHECK: P/Pa + (Cmx*Mx)/(Max*px) :5 1.33 PIPao + Mx/Max :5 1.33 Pno= Ae*Fy = 0.915 IN2 *50000 PSI = 45,750 LB Pao-- Pno/flc = 45750 LB/1 .81237446447951 = 25,243 LB Myield=My= SX*FY = 1.2 INA3 * 50000 PSI = 60,000 IN-LB Max= My/flf = 6000O IN-E.B/1.6T = 35,928 IN-LB Pcr= uA2EI/(KL)maxA2 = UA2*29500 KSI/(1 .2*46 IN)A2 = 157,662 LB THUS, (EQ C4.1-1) (EQ. C4-3) (EQ C4-2) (EQ C4-1) (EQ C5-1) (EQ C5-2) A= 3.0 IN B= 3.0 IN C= 0.7IN t = 0.1046 IN Aeff = 0.915 INA2 Ix= 1.6501NA4 Sx = 1.200 INA3 rx=1.3041N Iy= 1.100INA4 Sy = 0.730 INA3 ry= 1.080 IN Kx= 1.2 Lx = 46.0 IN Ky= 0.80 Ly= 60.0 IN Fy= 50 KSI E= 29,500 KSI .Of= 1.67 Cmx= 1.0 Cb= 1.0 px= {1/[1 _(Qc*P/Pcr)]}A_1 = 11/[1(1.81*4560 LB/157662 LB)] JA-1 = 0.95 (4560 tB/231 02 LB) + (1*189Z1 IN-tB/(35928 INLB0.95) = a 75 <t33 0K (EOjC5.1) (4560 LB/25243 LB) + (18921 IN-LB/35928 IN-LB) = 0.71 <1.33, OK (EQ C5-2) DEPTH 'I, SIDE ELEVA11ON -SEIZMIC MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 • FAX: (909) 869-0981 161 ATLANTIC AVENUE• POMONA• CA 91768 PROJECT BREEZE COM FOR CS GOO-DALE SHEET NO. 90 OF 15 CALCULftrTED BY BOBS.. .. 11/9lcfl COLUMN ANALYSIS (3X3X1 2GA) CROSS AISLE LOADS ANALYZED PER DIV VII, CHAP 22 OF THE 1997 UBC. SECTION PROPERTIES BASED ON THE EFFECTIVE SECTION. Pstatic= 4,560 LB Pseismic= 269691 IN-LB/42 IN = 6,42t LB Ptotal= 10,981 LB My= VTh = 1629 LB * 7 IN = 11,403 IN-LB KxLx/rx = 1.2*46 IN/i .304 IN = 42.3 Kyly/ry = 0.8*60 IN/i .08 IN = 44.4 <=== (KI/r)max AXIAL Fe=nA2/(KUr)max.&2 =147.4KSI Fy/2= 25.0 KSI SINCE, Fe > Fy/2 THEN, Fn= Fy(1-FyI4Fe) = 50 KSI*[150 KSI/(4*1 47.4 KSI)] = 45.8 KSI Pn= Aeff*Fn =41,870LB (lc= 5/3 + (3/8)*R - (1 /8)*RA3 = 1.81 Pa= Pn/flc = 41870 LB/1 .81237446447951 = 23,102 LB P/Pa= 0.48 > 0.15 FLEXURE CHECK; P/Pa + (Cmx*Mx)/(Max*px) :S 1.33 P/Pao+ Mx/Max:5 1.33 Pno= Ae*Fy = 0.915 1NA2 *50000 PSI = 45,750 LB Pao= Pnolflc = 45750 LB/1 .81237446447951 = 25,243 LB Myield=My= Sy*Fy = 073]N3 50000 PSI = 60,000 IN-LB Max= My/flf = 60000 IN-LB/1.67 = 35,928 IN-LB Pcr= uA2EI/(KL)maxA2 (EQ. C4-3) (EQ C4-2) SECTION PROPERTIE (EQ C4-1) A= 3.0 IN B= 3.0 IN C= 0.75 IN t = 0.1046 IN Aeff = 0.915 INA2 (EQ CS-i) Ix= 1.6501NA4 (EQ C5-2) Sx= 1.200INA3 rx= 1.304 IN Iy= 1.1001NA4 V= 1,629 LB Sy = 0.730 INA3 Mseismic= 269,691 IN-LB ry= 1.080 IN h= 7 IN Kx= 1.2 DEPTH= 42 IN Lx = 46.0 IN Ky= 0.80 Ly=6001N Fy= 50 KSI E= 29,500 KSI flf= 1.67 Cmx= 1.0 Cb= 1.0 = nA2*29500KS1/(1.2*46 IN)AZ px= tttt-(Pcr)1t = 157,662 LB = {1/(1_(1.81237446447951*10981 LB/157662 LB))}A.-1 THUS, . . = 0.87 . . . (10981-03/23102 LB) + (1*11403 IN-LB)/(35928 INLB*0.87) = 0.84 <1.33, OK (EQ C5-1) O98-1 LB/252+3 LB-* (1-1403 IN-EB-13-5928 IN-LB3--• 0-75-- <33OK (EQ-e52)- ZMIC MATERIAL HANDLING ENGINEERING TEL: (909)869-0989 • FAX: (909)869-0981 161 ATLANTIC STREET • POMONA • CA 91768 PROJECT BREEZECOM FOR Cs GOODALE SHEET NO 10A OF 15 CALCULATED BY BOB S. DATE 11092001 BEAM ANALYSIS :TYPE 1-SIR BEAM TO COLUMN CONNECTIONS PROVIDE ADEQUATE MOMENT CAPACITY TO STABUZE THE SYSTEM, ALTHOUGH IT DOES NOT PROVIDE 100% FIXITY. THUS, THE BEAMS WILL BE ANALYSED ASSUMING THEY HAVE PINNED ENDS. FOR THE COMPUTATION OF BEAM TO COL MOMENT CAPACITY, THE PARTIAL FIXITY OF THE BEAM,(ASSUMED AT AN ARBITRARY 25% OF THE FIXED END MOMENT OR 2,000 in.Ib. WHICH -EVER IS. SMALLER) WILL-BE ADDED. I act = 108.0 in. 2.5" Imax=11950 + 1 200(M1/M2)]b/Fy ,SINCE M1/M2= 1.0. -'1-- I max =3150*b/Fy=158in. SINCE Imax> lact Fb = .60Fy = 30,000 psi. MAXIMUM STATIC LOAD PER LEVEL DEPENDS ON 4.1-875 BENDING CAPACITY I - I t=.0747in. M= Sx* Fb=wIA2/8 =33570in.lb. CAPACITY = 2(8*M/1) = 44201b. Sx = 1.119 jA3 MAXIMUM ALLOWABLE DEFLECTION (Lu 80). Ix = 2.430 jA4 A = 5wIA4/384E1 CAPACITY 2.[(384ElI(5*1 80*IA2)] = 52441b. MAXIMUM STATIC LOAD PER LEVEL IS 4,421 lb. ALLOWABLE AND ACTUAL BENDING MOMENT AT EACH LEVEL. Mstatic = wIA2/8 = LIVE.LOAD*L/(2*8) Mallow(static) = Sx * Fb M impact = bi 25*Mstatic . . M-allow(seismic) = 133 *.Sx * Fb Mseismic = Mconn (SEE LONG. ANALYSIS) LEVEL Mstatic Mimpact Mallow Mseismic Mallow RESULT 1.125 Mstatic (static) (seismic) 1 14849 16706 33569 18370 44759 GOOD 2 14849 .16.7-06 335S9 ....-14284 -44759 GOOD 3 14849 16706 33569 10445 44759 GOOD 4 14849 16706 33569 5071 44759 . GOOD O1 8INCHTHICK YPEA"WEID AREA= 1.270 INA2 MOMENT CAPACITY= 1 18,807 IN-LB Sx= 0.67 INA3 Y-BAR SEIMIC MATERIAL HANDLING ENGINEERING TEL: (909) 869.0989 • FAX: (909) 869-0981 161 ATLANTIC AVENUE• POMONA CA 91768 PROJECT BREEZE COM FOR . CS GOODALE . •. SHEET NO. •. 10f OF ' 15 cALUtATEDBY BOB..S... F DATE Lt19J,01. . ... .................,,....--.,, DETERMINE THE EFFECTIVE.- SECTION PROPERTIES OF THE MEMBER WELDSHQWN - BELOW; THE EFFECT OF THE ROUNDED CORNERS ARE TAKEN INTO ACCOUNT; IIii II'::i Li TYPE "B" WELD TYPE "C" WELD TYPE "D" WELD TYPE "A" WELD BEAM & WELD INFO D=M tweld*= 0.1 88.IN Fu= 70,000 PSI (i (LTYPE "A" WELD 0 20 EFFECTIVE SECTION PROPERTY -FOR WELD I ELEMENT I WIDTH - I HEIGHT I Y-BAR ELEM. 1 0.0000 IN 0.0000 IN 0.0000 IN 2 0.1875 IN 4.2000 IN 2.1000 IN : 3 0.0000 IN 0.0000 IN 0.0000 IN 4 0.0000 IN 0.0000 IN 0.0000 IN 5 0.0000 IN 0.0000 IN 0.0000 IN 6 0.18751N 2.57501N 128751N AREA= WELD MOMENT CAPACITY UNDER SEISMIC LOADING CAPACITY= 0.3 * Fu * Sx-weld * 1.33 = 0.3 * 70000 PSI * 0.673 INA3 * 1.33 = 18,807 IN-LB I AREA I1BAR ......I 0.0000 INA2 :: ::: ::: : : 0.0000iNA4 0.787S INA2 :•: : 1.23271NA4 00000 INA2 00000 INA4 0.0000 INA2 0.0000INA4 0.0000 INA2 : : :::: 0.0000INA4 0.4828 INA2 0.38931NA4 1.27031NA2 ybar= 1.791 IN • . Ix= 1.62201NA4 C= P1+P2+P3 - 01 +P1 *(1 5/4 5)+Dl* A 5/4 5) 1 .67*P1 Sbracket= 0.110 INA3 -4, MIC MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 • FAX: (909) 869-0981 161 ATLANTIC AVENUE• POMONA CA 91768 Mconn max= .Mconn. seismic + Mend =1 37ZiN-LB I - PROJECT BREEZE COM FOR CS.GOODALE SHEET NO. •11 OF 15 CALULATED BY- BOB S - DATE- i 1-/9/0.1. -Mupper CONNECTION CAPACITY DEPENDS ON THE FOLLOWING PARAMETERS: 1) SHEAR CAPACITY OE.STUDS STUD DIAMETER= 7/16 IN Fy= 50,000 PSI Mcc nn Mconn -j'oo 0 Pmax-shear= 0.4 * Fy * Area 0.4 *.50000PSJ* (0:4375 1N)A2n/4 = 3,006.6 LB BEARING CAPACITY ON COLUMN Fu= 65,000 PSI Pmax-brg= Bearing Area * Fbearing = (0.5 * thickness) * (1.0 * Fu) = (0.5 * 0.1046 IN) * (1.0 *65000 PSI) 3,399.5 LB >3006.6 LB MOMENT CAPACITY OF BRACKET Mcap= Sbracket * Fbending = 0.11 INA3 * 0.66 * Fy = 3,630 IN-LB C= Mcap/0.75 = 1.67 * P1 THUS, P1= 0.798 * Mcap 2,897 IN-LB <3006.6 LB THUS, GOVERNING YALUE1STHE MINVALUEOFP1, P1-eff= 2,897 LB Mconn-allow= P1*4.5 IN + P2*2.5 IN + P3*05 IN = 5.94*P1eff* 1.33 = 22,942 IN-LB > Mconn max, OK Miower t:SfElZMlC::n MATERIAL HANDLING ENGINEERING TEL: (909)869-0989 9 FAX: (909)869-0981 161 ATLANTIC STREET • POMONA • CA 91768 PROJECT BREEZECOM FOR CSG000AL€ SHEETNO. 12 OF 15 CALCULATED BY_BOB S. DATE _11-09-200 1 IT IS ASSUMED THAT THE LOWER PANEL RESISTS THE FRAME SHEAR IN TENSION AND COMPRESSION. IF HORIZONTAL AND DIAGONAL MEMBERS ARE THE SAME, ANALYSIS WILL BE DONE ON THE DIAGONAL MEMBER AS IT WILL GOVERN. DIAGONALBRACING:COMPRESSIONMEMBER L diag. = [(L6)A2+(D2*BcoI)A2]A.5 = 64.8. Vdiag =Vtrans * Ldiag. / D = 2516# kl/rmin = [1 * 64.8 ] /.523 =124.0 Fa =[1 211A2E]/[23(kl/r)A2] = 9697 psi. fa/Fa =Vdiag/(Area*Fa) =0.94 D=42" 1 DIAGONAL AND HORIZONTAL BRACING HWH irff Area= .277 "A2 H ri I rmin= .523 LI 0 t=06" Ii Hi W=15 Ca 0 " H= 1.5 651 488# 10 325# -, 1•62# .L 42"- C: fSE :C::2 .4 INC MATERIAL HANDLING ENGINEERING TEL: (909)869-0989 9 FAX: (909)869-0981 161 ATLANTIC STREET • POMONA • CA 91768 PROJECT BREEZECOM FOR CSG000ALE SHEET NO- 13 OF 15 CALCULATED BY_ BOB S. DATE _11-09-200 1 OVERTURNING _:TYPE 1-SIR ANALYSIS OF OVERTURNING WILL BE BASED ONSECTION 228.7.1 OF THE 1997 Uniform Building Coth FULLY LOADED TOTAL SHEAR = 1628 lb. Mot =Vtrans*ht* 1.15 =1628*143*1.15 = 269691 in.Ib. Mst = (Wp+.85wDL) * d12 = ( 8800+.85 * 320) * 42/2- 190512 in.1b. Puplift = 1 (Mot - Mst)/d 1885 lb. <- CRITICAL TOPSHELFLOADED SHEAR = 407 lb. - Mot =Vtop*h*.i..15 =407 * 192 * 1.15 = 89897 in.Ib. Mst = (Wp+wDL) * d/2 = ( 2200+.85 * 320) * 42/2 = 51912 in.Ib. Puplift = 1 (Mot - Mst)/d = 904 lb. USE 2 ea. 1/2 x 3-1/2 MIN. EMBED. ANCHOR. CAPACITY OF 1/2 x3-1/2 = 1496 lb. PULLOUT & 2447 lb. SHEAR COMBINED STRESS =1S85 / 292 + 814 -1-4894 =0.80 COMBINED STRESS2 = 904 / 2992 + 203 / 4894 = 0.34 f: fSE I Z:M I :C::2 INC- MATERIAL HANDLING ENGINEERING TEL: (909)869-0989 • FAX: (909)869-0981 161 ATLANTIC STREET • POMONA • CA 91768 PROJECT. BREEZECOM FOR CSGOODALE SHEET NO. 14 OF_15 CALCULATED BY_ BOB S. DATE 11-09-2001 BASE PLATE :TYPE 1 -SiR BASE PLATE WILL BE ANALYZED WITH THE RECTANGULAR STRESS RESULTING FROM THE VERTICAL LOAD P, COMBINED WITH THE TRIANGULAR STRESSES RESULTING FROM THE MOMENT Mb (IF ANY). THERE ARE 3 CRITERIA IN DETERMINING Mb. THEY ARE 1) MOMENT CAPACITY OF THE BASE PLATE, 2) MOMENT CAPACITY OF THE ANCHOR BOLTS, AND 3) Vh/2 (FULL FIXITY). Mb IS THE SMALLEST VALUE OBTAINED FROM THE 3. CRITERIA ABOVE. Mbase = wbi "2/2 = bi "2/2t fa + fbi + .67fb2] Mbase = 843.8 in-lb. Pcol=4560lb. B=8 in. D=5 in. Mb = 10509 in.lb. b = 3 in. P/A = Pcol/(D*B) 114 psi. WS =Mb/((D*BA2)/6) = 197.0 psi. fb2 = 2b/B*fb = 123.1 psi. fbi = fb-fb2 = 73.89 psi. S base = 1 *A/ = 0.0234 jn."3 Fbase = .75fy * 1.33 36000 psi. fb/Fb M base/(Sbase*F base) = .99 ANCHOR TENSION Mo=0 T*d2=[Mbase pcol*b/2] T = Mbaseld2 - Pcol*b12d2 T= 815 lb. t=.375 in. bi = 2.5 in. faLl I 1 1 11 1 111 fb LLLLL'fbl IMbase _d2 d1 b bi B S:E MIC MATERIAL'HANDLING ENGINEERING TEL: (909)869-0989 9 FAX: (909)869-0981 161 ATLANTIC STREET • POMONA • CA 91768 PROJECT BREEZECOM - FOR CS GOODALE SHEET NO- 15 OF 15 CALCULATED BY BOB S. DATE 11-09-2001 SLAB AND SOIL :TYPEi -SIR THE SLAB. WILL BE CHECKED FOR PUNCTURE STRESS. IF NO PUNCTURE OCCURS, IF WILL BE ASSUMED TO DISTRIBUTE THE LOAD OVER A LARGER AREA OF SOIL AND WILL ACT AS A FOOTING. (a) PUNCTURE Pmax=1.4 DEAD LOAD +1.7 LIVE LOAD Pmax = 1.4 Pcol + 1.7 * (Mot/d) = 17,300 lb. Fpunct = 2*sqrt(f'c)= 126.5 psi. Apunct = [(w+t/2)+(dit/2)]*2*t = 180.0 in.A2 fv/Fv = Pmax/(Apunct*Fpunct) = 0.76 (b) SLAB TENSION Asoil = Pmax/(1 .33 * fsoil) = 12.98 ft.A2 = 1,868 in.A2 L = sqrt(Asoil) = 432 in. B = sqrt(w*d)+t= 11.3 in. b = (L-B)/2 = 16.0 in. Mconc = wbA2/2 = (1 33*fSojl*bA2)/(1 44*2) = 1,177.8 in.Ib. Sconc = 1 *tA2/6 = 4.17 jA3 Fconc = 50 *sqrt(flc) = .284.60 psi. fb/Fb = Mconc/(Sconc*Fconc) = 0.99 BASE PLATE w=8in. d = 5 in. CONCRETE t = 5 in. f'c = 4000 psi. SOIL ft = 1000 psf. ROCBAD _____ '•qII 7LEANED iI-I-o(6A ,. PLANNING ENGINEERING FIRE APPIVFORM HEALTH DEPT HAZ MAT! AIR DUAL OTHER SEWER DERfi BlDG GRADING LETTER TO FROM APPUCANT APPUCANT MIN COM ENO cam SICHOOLFORM CFO RM _____PS &MWENERW _____DIDG PEER COMPLIM