Loading...
HomeMy WebLinkAbout2121 PLACIDO CT; ; CB031989; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit Permit No: CB031989 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: Applicant: Building Inspection Request Line (760) 602-2725 2121 PLACIDO CT CBAD RESDNTL Sub Type: Lot#: 2164920600 $0.00 Construction Type: Reference #: 0 Structure Type: O Bathrooms: WELSHONS RES-SOLAR PHOTOVOLTAI SYSTEM ON ROOF RAD 0 NEW 0 Owner: Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Orig PC#: Plan Check#: ISSUED 07/17/2003 RMA 09/03/2003 09/03/2003 BORREGO SOLAR SYSTEMS BEVERLY DONALD K&WELSHONS KIM 6210 LAKE SHORE DR 92119 619 697-7183 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee STD #2 Fee STD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee Total Fees: $120.00 Inspector: ""' $0.00 $0.00 $0.00 $0.00 $0.00 $1.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $119.00 $0.00 $0.00 $0.00 2121 PLACIDO CT CARLSBAD CA 92009 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWAFee CFD Payoff Fee PFF PFF (CFD Fund} License Tax License Tax (CFD Fund} Traffic Impact Fee Traffic Impact (CFD Fund} Sidewalk Fee PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Housing Impact Fee Housing lnlieu Fee Housing Credit Fee Master Drainage Fee Sewer Fee Additional Fees TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $120.00 Total Payments To Date: $0.00 Balance Due: $120.00 FINAL AP ROVAL Date: z..l v.:J 3215 09/03/03 0002 01 CGP Clearance: NOTICE: Please take NOTICE at approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." u have 90 days from the date this pennlt was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures se forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any f f whi h uh r vi I n N Tl E imil h' h f lim· . n h 02 120,00 FOR OFFICE USE ONLY no .PERMIT APPLICATION PLAN CHECK NO. CJ] {A I qJ I CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 EST. VAL. __________ _ Plan Ck. Deposit-----.------ Validated By /1i:.. Date ~ { { i { qj Business Name (at this address) Legal Description Lot No. Subdivision Name/Number Unit No. Phase No. Total # of units 2 L~-Y~1 -D<o-00 ( .(..5,·J.t,v-, h'aj ~ Assessor's Parcel # EWting Use Of\ r@\: Proposed Use 2014 r ~vol½k ~, skwJ Description 7fWork SO. FT. #of Stories # of Bedrooms # of Bathrooms 2. CONTACT PERSON (If different from applicant) Tl obe ct 1)~{..e 'f b IW LAla. ~ Name Address pt ~o.. a. City (..Ii CA <j-u I 't ~,c;-~c:fl.;Jff3 r,9'.l-'-l \Ol State/Zip Te ephone # Fax # 3 0 Agent for Contractor t 4. PROP~RY flWNf-.cR KrM ""'-ti 2VLot\S Name Address City Telephone# 6. CONTRACTOR· COMPANY NAMl: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, Improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code! or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 b any applicant for a permit subjects the applicant to a civil penalty of not more ~an five hundred ~ollars ($500)). <Jf 14.r , 2.. 0 ....... ,,. .. -r-1 r · a .,. b,f --<u<t -t Address City State/Zip Telephone # Sta~ License # _j._..}_vi_£;_,,\)....,_ ... $:'-----License Class l, -Lf (c, City Business License # ~ber+ rksskA ~ -z,1 ° (g,1£..e.Sb,-!, De la. M.Y<-i cA nu-q,--~-,-CJ----G,9:7-Jld) Designer Name Address City State/Zip lephone State License # -'1s'~/4_,_'1-"-"3:...:S':;__ __ _ 6. WORKERS' COMPENSATION Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: O I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ~ I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's comP,ensation insurance carrier and policy number are:) Insurance Company U.f.c. ~ Policy No. \] (1_£{S" -0"2_ Expiration Date ,0/(/ 0 2_ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($1001 OR LESS) 1 l O CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars [$100,000), In addition tot mpensation, damages as provided for In Section 3706 of the Labor code, interest and attorney's fees. SIGNATURE_J~~~'.q;~~y~:::::::X-------------DATE :--'7,~/.,_(711/i;;--'Q).""?~-::==:..,_.,,----,.-- 7_ OWNER-BUil ER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: O I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). O I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). O I am exempt under Section ______ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ONO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ contractors license number): ______________________________________________ _ 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): ________________________________________________________ _ PROPERTY OWNER SIGNATURE _______________________ _ DATE -----------COMPLETE THIS SECTION FOR NON-RESIOENnAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES O NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES O NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES O NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES ANO THE AIR POLLUTION CONTROL DISTRICT. 8. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME ______________ _ LENDER'S ADDRESS ----------------------------9. APPLICANT CERTIFICATION I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY ANO KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is com enced for a period of 180 days ( · 6.4.4 Uniform Building Code). DATE '"'(( ]/0) LLOW: Applicant PINK: Finance City of Carlsbad Bldg Inspection Request For: 11/20/2003 Permit# CB031989 Title: WELSHONS RES-SOLAR PHOTOVOLTAI Description: SYSTEM ON ROOF Type: RESDNTL Sub Type: RAD Job Address: Suite: Location: 2121 PLACIDO CT Lot 0 APPLICANT BORREGO SOLAR SYSTEMS Owner: BEVERLY DONALD K&WELSHONS KIM Remarks: Total Time: CD Description Act Comment Inspector Assignment: PY --- Phone: 6196977183 Inspector: ----- Requested By: ROBERT Entered By: CHRISTINE 39 Final Electrical P4-~Q l\c'.4-o:;, Associated PCRs/CVs PCR03111 ABANDOND COMBINED INTO PCR03-132: BEAMS@ FAM RM,MSTR BDRM,LAU,FIREPLACE PCR03117 ABANDOND COMBINED INTO PCR03-132: HIP CHANGE/ CLOSET PCR03132 ISSUED WELSHONS RES-REVISE FIREPLACE: Inspection History Date Description Act lnsp Comments 11/06/2003 39 Final Electrical CO PY NEED GROUND DATE: 8/12/03 JURISDICTION: Carlsbad PLAN CHECK NO.: 03-1989 EsGil Corporation In <Partnersnip witn <;overnmentforl/Jui[aing Safety SET: II PROJECT ADDRESS: 2121 Placido Court PROJECT NAME: Welshons SFD Solar Photovoltaic □ APPLICANT Q___JURIS.::) □ PLAN REVIEWER □ FILE X The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. 0 The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. 0 The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: X Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person cohtacted: Telephone#: Date contacted: (by: ) Mail Telephone Fax In Person 0 REMARKS: By: Eric Jensen Esgil Corporation 0 GA O MB O EJ O PC Enclosures: 8/7 Fax#: trnsmtl.dot 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax(858) 560-1576 ------·-·•-.·--···· DATE: 7/30/2003 JURISDICTION: Carlsbad PLAN CHECK NO.: 03-1989 EsGil Corporation In IPartnersnip witn qo-vernment for <Bui(aing Safety SET:I PROJECT ADDRESS: 2121 Placido Court □~NT ~__) □ PLAN REVIEWER □ FILE PROJECT NAME: Solar Photovoltaic System (.,.JE LS/-KliJ S Sh>) D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. X The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. X The applicant's copy of the check list has been sent to: Robert Bessler Lake Shore Drive La Mesa CA 92119 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. X Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Robert Bessler (\.l,H) Telephone#: 619 697-7183 Date contacted:1 ho/D..)(by: Lt_) Fax #: 619 697-4300 Mail '-'"'Telephone✓ Fax✓ In Person 0 REMARKS: By: Eric Jensen Esgil Corporation 0 GA O MB O EJ O PC Enclosures: 7/21 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad 03-1989 7/30/2003 GENERAL PLAN CORRECTION LIST JURISDICTION: Carlsbad PROJECT ADDRESS: 2121 Placido Court DATE PLAN RECEIVED BY ESGIL CORPORATION: 7/21 REVIEWED BY: Eric Jensen FOREWORD (PLEASE READ): PLAN CHECK NO.: 03-1989 DATE REVIEW COMPLETED: 7/30/2003 This plan review is limited to the technical requirements contained in the Uniform-Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. • Please make all corrections on the original tracings and submit two new complete sets of prints to: ESGIL CORPORATION. • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? O Yes D No Catlsbad 03-1989 7/30/2003 ELECTRICAL CORRECTIONS PLAN REVIEWER: Eric Jensen 1. The licensed designer must sign the-approved set of the plans. ELECTRICAL (1999 NATIONAL ELECTRICAL CODE) 2. Include, on the single line diagram, the PV grounding electrode system: Conductor size, connection termination locations, and routing. NEC 690-47 3. The 30 ampere 240 volt AC overcurrent device appears oversized. Please justify. Additionally, note on the single line diagram that this device will be positively attached to the panelboard, the sole use of a stab-in connection will not be permitted. NEC 384-16(9) 4. Provide the module manufacturers DC maximum overcurrent protection device sizing, note on the plans, and demonstrate how this protection is provided on the single line diagram. 5. The solar panel design specifies 3,900 watts maximum power, the inverter installation specifications specify a maximum input of 3,000 watts of PV power. Please address. 6. The 600 volt disconnects: Why 4 poles? It doesn't appear to match the 3 parallel panel designs. 7. Where did the 3,750 inverter output wattage come from? Isn't the Sunny Boy listed as 2,500 watts? Note: See 690-8(a)3. For ampacity and OC device sizing the 2,500 watts X 125% would equal 3,125 watts (13.2 amperes_ Note: If you have any questions regarding this Electrical plan review list please contact Eric Jensen at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. Carlsbad 03-1989 7/30/2003 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 03-1989 PREPARED BY: Eric Jensen DATE: 7/30/2003 BUILDING ADDRESS: 2121 Placido Court BUILDING OCCUPANCY: TYPE OF CONSTRUCTION: BUILDING AREA Valuation Reg. VALUE PORTION ( Sq. Ft.) Multiplier Mod. Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance -.. ---a• --- 1994 UBC Buildin Permit Fee g ..,, __ 19_94_1:l_BC_Plan_Chec_k_Fe_e __ 3 Type of Review: □ Complete Review D Structural Only D Repetitive Fee i-----;7 Repeats • Based on hourly rate Comments: □ Other 0 Hourly 1 I Hour* Esgll Plan Review Fee ($) . $120.ool $96.001 Sheet 1 of 1 macvalue.doc , DATE: July 14, 2003 JURISDICTION: Carlsbad PLAN CHECK NO.: 02-2379 EsGil Corporation In ,Partnmfiip witfi qcwemment for (]Juiffi11Q Safety SET: Il(REV 3) PROJECT ADDRESS: 2121 Placido Ct. PROJECT NAME: Welshons Add. -SFD -Proposed plan changes 0 APPLICANT ~ ~EVIEWER □ FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. IZJ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. IZJ The applicant's copy of the check list has been sent to: John S. Beery Architect P.O. Box 130684, Carlsbad, CA 92013-0684 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. IZJ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: John Berry Telephone#: (760) 438-2963 (0,-,A✓A 1cA61.,E) Date contacted: -::i-li'-1/05 (by:fA><-) Fax #: (760) 438-2963 Mail <..--"Telephone 0 REMARKS: Fa,._,, In Person By: Sergio Azuela Esgil Corporation D GA D MB D EJ D PC Enclosures: 7/3 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad 02-2379 July 14, 2003 RECHECK PLAN CORRECTION LIST JURISDICTION: Carlsbad PROJECT ADDRESS: 2121 Placido Ct. DATE PLAN RECEIVED BY ESGIL CORPORATION: 7/3 REVIEWED BY: Sergio Azuela FOREWORD (PLEASE READ): PLAN CHECK NO.: 02-2379 SET: I (REV 3) DATE RECHECK COMPLETED: July 14, 2003 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit two new sets of prints to: ESGIL CORPORATION. B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? □Yes □No Carlsbad 02-2379 July 14~ 2Q03 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. Provide a complete list of all proposed plan changes, including: a) A brief description of each proposed plan change. b) The sheet or sheets of plans that shall be modified for each proposed plan change. c) The identification symbol and number used to identify the proposed plan change on the plans. 3. Please note that the Masonry Fireplace Standards Drawing and Specifications provided are not applicable for the cases presented on the original plans, since the fireplaces shown on the plans are stacked. • Provide sizing calculations per UBC Chapter 31, figure 31-1, for the masonry flue sizing. Additionally, justify the manufacture red chimney extensions sizing and detail the size and shape connection between the masonry and manufacture red chimneys onto the plans. (All fireplaces) If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. PLANNINO/ENCINEERINC APPROVALS PERMIT NUMBER CB 03 fq09' ADDRESS Q.l;l. I . Pl (1..Cl d O ~ t RESIDENTIAL ADDITION MINOR ( < $10,000.00) DATE '1-1 'o .. 0.3 TENANT IMPROVEMENT PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLACE FAIRE COMPLETE OFFICE BUILDING OTHER ___________________ _ DATE '7-l!-03 DATE ______ 1li_r(_/rf1 __ Doc.s/Mtsfonns/Ptannlno Engineering Approvals