Loading...
HomeMy WebLinkAbout2020 CASSIA RD; 103; CBC2019-0602; PermitBuilding Permit Finaled Lbty of Carlsbad Commercial Permit Print Date: 07/14/2020 Permit No: CBC2019-0602 Job Address: 2020 CASSIA RD, # 103, CARLSBAD, CA 92009-4211 Status: Closed - Finaled Permit Type: BLDG-Commercial Work Class: Tenant Improvement Parcel #: 2150210200 Track #: Applied: 12/26/2019 Valuation: $240,823.12 Lot #: Issued: 04/02/2020 Occupancy Group: Project #: Finaled Close Out: #of Dwelling Units: Plan #: - Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: PBurn Plan Check #: Final Inspection: 07/14/2020 Project Title: Description: SAN DIEGO ENT SPECIALIST: 3721 SF TENANT IMPROVEMENT, MED OFFICE TO MED OFFICE Applicant: Property Owner: Contractor: AVENT DESIGN MIDWEST INVESTMENT PROPERTIES LIC KYLER CONSTRUCTION INC 28720 SAN DHURST WAY 2020 CASSIA RD 5041 BELLA COLLINA ST ESCONDIDO, CA 92026-6805 CARLSBAD, CA OCEANSIDE, CA 92056-1924 (619) 889-9481 (760) 784-0635 FEE AMOUNT BUILDING PERMIT FEE ($2000+) $1,126.55 BUILDING PLAN CHECK FEE (BLDG) $788.58 ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL $89.00 GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION $175.00 MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL $55.00 5B1473 GREEN BUILDING STATE STANDARDS FEE $10.00 STRONG MOTION-COMMERCIAL $67.43 Total Fees: $2,311.56 Total Payments To Date: $2,311.56 Balance Due: $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar-application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-2700 1'760-602-8560 f I www.carlsbadca.gov (City of Carlsbad COMMERCIAL BUILDING PERMIT APPLICATION B-2 Plan Check Est. Value 2-fC),f23 PC Deposit Date 1'2--2— "r Job Address '2)2c' 1tSSI6 O( Suite:M10 APN:2i 5 O 21 )20O Tenant Name: V(. 54 ht4i 'Pi 144- CT/Project It: Lot It:________ Occupancy: Construction Type: ( Fire Sprinklers: e no Air Conditioning: es o BRIEF DESCRIPTION OF WORK: 1 7,/tU(yi- Addition/New: New SF and Use, New SF and Use, Deck SF, ________ Patio Cover SF (not including flatwork) Tenant Improvement: _____ SF, Existing Use " Proposed Use -5 SF, Existing Use off Proposed Use O Pool/Spa: SF Additional Gas or Electrical Features? Solar: KW, _Modules, Mounted, Tilt: Yes / No, RMA: Vest No, Panel Upgrade: Yes / No 0 Plumbing/Mechanical/Electrical Only: 0 Other: Name: 411-Vl,1 4--'t Address: 14 I City:f,'fiut4C c4 C' Phone: &I C4 -9 Email: DESIGN PROFESSIONAL Name: Address: City: Phone: Email: Architect State License: PROPERTY OWNER Name: 9'- ~kf t4Ci4 T.piJ Address: 2ôô 7zS)'U. (t4 City: (-tA15 WCd stat!-k Zip:________ Phone: Email: CONTRACTOR BUSINESS Name: )(Jp (-;ri I,-)(- Address: 56) II.nc, S City: OcJe_State: Zip: Phone: -7 &D -7t oS Email: -bv\\i k,f e.*c1 Lc5w\ State License. wl L7äf/ç3 - Bus. LicenseL LoSGO33? (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: BuildingccarIsbadca.gov B-2 Page lof2 Rev. 06/18 (OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury one of the following declarations: CII have and will maintain a certificate of consent to self-Insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. I1ive and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit Is issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name:_ Policy No.CCO I LI b5 Expiration Date: 2/ 7J(fZr20 O Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for In Section 3706 of the Labor Code, interest and attornefs fees. CONTRACTOR SIGNATURE: 0 AGENT DATE: (OPTION 6 ): OWNER-BUILDER DECLARATION: I hereby affirm that lam exempt from Contractor's License Law for the following reason: CI I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). O I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). Cl lam exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. DYes I) No 2.1 (have / have not) signed an application for a building permit for the proposed work. 3.1 have contracted with the following person (firm) to provide the proposed construction (include name address I phone / contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address / phone! contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address! phone / type of work): OWNER SIGNATURE: DAGENT DATE:___________ CONSTRUCTIONLENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: Lender's Address: ONLY COMPLETE THEFOLLOWINGSECTIONFOR NON-RESIDENTIAL BUILDINGPERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 Yes 0 No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 Yes 0 No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? DYes Cl No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City ofCarlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TOSAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHk An OSHA permit is required for excavations over 5'O' deep and demolition or construction of structures over 3 stones in height EXPIRAtiON: Every permit issued by the BuildipeQfficial under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 1 daysf m the date of such perpil orifthe building or work authonzed by such permit lssucpended or abandoned at any time after the work is commenced fora pen 80da (Section 106.4.4U o Building Code). APPLICANT SIGNATURE: - J2-t _ DATE: 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: BuiIdingccarIsbadca.gov B-2 Page 2 of 2 Rev. 06118 PermitType: BLDG-Commercial Application Date: 12/26/2019 Owner: MIDWEST INVESTMENT PROPERTIES LLC Work Class: Tenant Improve?nent Issue Date: 04/02/2020 Subdivision: Status: Closed - FinaIed Expiration Date: 12/23/2020 Address: 2020 CASSIA RD. #103 IVR Number: 23899 CARLSBAD, CA 92009-4211 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status Checklist Item COMMENTS Passed BLDG-Building Deficiency 6/30/20, see back of card for pick up. No BLDG-Building Deficiency • 7/09/20, accessible parking striping not Yes compliant. - BLDG-Building Deficiency 7/01/20, TCO granted, see card for minor Yes • pick up.n BLDG-Plumbing Final 6/30/20, see back of card No BLDG-Mechanical Final' . No BLDG-Structural Final. No BLDG-Electrical Final 6/30/20, see back of card for pick up No L94!2O2OO7/14/202O BLDG-Final Inspection 132648-2O20 Passed • Michael Collins • • Checklist Item COMMENTS • Passed BLDG-Building Deficiency 7/01/20, TCO granted, see card for minor • • Yes pick up.n BLDG-Building Deficiency 6/30/20, see back of card for pick up. No BLDG-Building Deficiency 7/09/20, accessible parking striping not • Yes . compliant. BLDG-Building Deficiency 1 7/14/20 ' Yes BLDG-Plumbing Final 6/30/20, see back of card No BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final BLDG-Electrical Final 6/30/20, see back of card for pick up Yes Yes No No Yes No Tuesday, July 14, 2020 Page 4 of 4 Permit Type: BLDG-Commercial Application Date: 12/26/2019 Owner: MIDWEST INVESTMENT PROPERTIES LLC Work Class: Tenant Improvement Issue Date: 04/02/2020 Subdivision: Status: Closed - Finaled Expiration Date: 12/23/2020 Address: 2020 CASSIA RD, # 103 IVR Number: 23899 CARLSBAD, CA 920094211 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status Checklist Item COMMENTS Passed BLDG-Building Deficiency June 25, 2020: . No T-barlceiling grids, overhead scope of work not ready. Required overhead fire sprinkler/fire department inspection prior to final building inspection. Spoke to superintendent Tony. and informed fire dept. clearances completed prior to building inspection final. BLDG-Building Deficiency June 26, 2020: Yes T-bar/ceiling grids, overhead scope of work ready-approved. Required overhead fire sprinkler/fire department inspection-approved. Spoke to superintendent Tony and informed ADA restroom clearances to be completed prior to building inspection final. 0612912020 .0612912020 BLDG-Final Inspection - 131366-2020 .: Failed Paul Burnette Reinspection Incomplete Checklist Item COMMENTS Passed BLDG-Building Deficiency . No BLDG-Plumbing Final No BLDG-Mechanical Final . No BLDG-Structural Final No BLDG-Electrical Final No 0613012020 0613012020 BLDG-Final Inspection 131487-2020 Failed Michael Collins. Reinspection Incomplete Checklist Item COMMENTS Passed BLDG-Building Deficiency 6/30/20, see back of card for pick up. No BLDG-Plumbing Final 6/30/20, see back of card No BLDG-Mechanical Final No BLDG-Structural Final No BLDG-Electrical Final 6/30/20, see back of card for pick up No 0710112020 07101/2020 BLDG-Final Inspection 131669.2020 Partial Pass Michael Collins - Reinspection Incomplete Checklist Item COMMENTS Passed BLDG-Building Deficiency 7/01/20, TCO granted, see card for minor Yes pick up.n BLDG-Building Deficiency 6/30120, see back of card for pick up. No BLDG-Plumbing Final 6/30/20, see back of card No BLDG-Mechanical Final No BLDG-Structural Final . No BLDG-Electrical Final 6/30/20, see back of card for pick up . No 07/0912020 07I0912020 BLDG-Final Inspection 132256-2020 - Partial Pass Michael Collins Reinspection Incomplete Tuesday, July 14, 2020 . Page 3 of 4 Permit Type: BLDG-Commercial . Application Date: 12/26/2019 Owner: MIDWEST INVESTMENT PROPERTIES LLC Work Class: Tenant Improvement Issue Date: 04/02/2020 Subdivision: Status: Closed - Finaled Expiration Date: 12/23/2020 Address: 2020 CASSIA RD. # 103 IVR Number: 23899 CARLSBAD, CA 92009-4211 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 0511512020 05/1512020 BLDG-18 Exterior 127673.2020 Passed Peter Dreibelbls Complete Lath/Drywall - - - . - ............- - Checklist Item COMMENTS Passed BLDG-Building Deficiency Elec. at subfeed area. Ok to hang and tape No 06/24/2020 06I24I2020 BLDG-85 T-Bar, Ceiling 130950.2020 Cancelled Michael Collins . Reinspection Incomplete Grids, Overhead - - - Checklist Item COMMENTS Passed BLDG-Building Deficienày No BLDG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 . No Rough-Ducts-Dampers 06/25/2020 06125!2020 BLDG-85 T-Bar, Ceiling 131024-2020 Failed Tony Alvarado Reinspection Incomplete Grids, Overhead - Checklist Item COMMENTS Passed BLDG-Building Deficiency June 25, 2020: No T-bar/ceiiing grids, overhead scope of work not ready. Required overhead fire sprinkler/fire department inspection prior to final building inspection. Spoke to superintendent Tony and informed fire dept. clearances completed prior to building inspection final. 06126/2020 06/26/2020 BLDG-85 T-Bar, Coiling 131176-2020 Partial Pass Tony Alvarado . Reinspection Incomplete Grids, Overhead - . .. Tuesday, July 14, 2020 Page 2 of 4 Building Permit Inspection History Finaled (7city of Carlsbad Permit Type: BLDG-Commercial Application Date: 12/26/2019 Owner: MIDWEST INVESTMENT PROPERTIES LLC Work Class: Tenant Improvement Issue Date: 04/02/2020 Subdivision: Status: Closed - Finaled Expiration Date: 12/23/2020 Address: 2020 CASSIA RD. # 103 IVR Number: 23899 CARLSBAD, CA 92009-4211 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 0412012020 0412012020 BLDG-21 125071-2020 Passed Paul Burnette Complete Underground!Underflo or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 0412912020 0412912020 BLDG-44 125973-2020 Partial Pass Paul Burnette Reinspection Incomplete Rough/Ducts/Dampers Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 0510112020 05!0112020 BLDG-24 Rough!Topout 126239.2020 Passed Paul Burnette Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 0510612020 0510612020 BLDG-17 Interior 126618-2020 Failed Paul Burnette Reinspection Incomplete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-44 126616-2020 Cancelled Paul Burnette Reinspection Incomplete Rough/Ducts/Dampers Checklist Item COMMENTS Passed BLDG-Building Deficiency • Yes BLDG-84 Rough 126761-2020 Passed Paul Burnette Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 • Yes Rough-Ducts-Dampers 0511112020 0511112020 BLDG-17 Interior 127088.2020 Passed Michael Collins Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency All walls except at sub feed locations Yes Tuesday, July 14, 2020 Page 1 of 4 EsGil A SAFEbuiIt Company DATE: MARCH 26, 2020 JURISDICTION: Carlsbad PLAN CHECK #.: CBC2019-0602 SET: III PROJECT ADDRESS: 2020 Cassia Rd. #103 PROJECT NAME: Dr. Stephen Dent Tenant Improvement APPLICANT JURIS. The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. El The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. E The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. E The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. E The applicant's copy of the check list has been sent to: EsGil staff did not advise the applicant that the plan check has been completed. E EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Avent Design Telephone #: 619-889-9481 Date Email: aventdesign©cox.net Mail Telephone Fax In Person LI REMARKS: By: ALl SADRE S.E. Enclosures: EsGil 3/25 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGfl A SAFEbuItI'Company DATE: MARCH 209 2020 U APPLICANT U JURIS. JURISDICTION: Carlsbad PLAN CHECK #.: CBC2019-0602 SET: II PROJECT ADDRESS: 2020 Cassia Rd. #103 PROJECT NAME: Dr. Stephen Dent Tenant Improvement El The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. ü The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. EJ The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. PLEASE SEE BELOW EJ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Avent Design Telephone #: 619-889-9481 Date contacted: (by: ) Email: aventdesign©cox.net Mail Telephone Fax In Person REMARKS: Please see attached for remaining items from previous list. By: Connor Reuss & Ali Sadre (for J.P.) Enclosures: EsGil 2/28/20 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad CBC20 19-0602 MARCH 20, 2020 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. NON-RESIDENTIAL GREEN BUILDING STANDARDS (Alterations) -These notes are not imprinted on Sheet TS2I as per response list. The California Building Standards Commission (BSC) has adopted the Green Building Standards Code and must be enforced by the local building official. The Green Building Standards apply to nonresidential additions or tenant improvements throughout California. These standards apply to nonresidential additions of 1,000 sq. ft. or larger or alterations (tenant Improvements) with a value of $200000 or more. CGC Section 301.3. Provide a sheet on the plans labeled "Green Building Code Requirements" and include the following notes as applicable. Provide documentation with any applicable details that will show compliance with the Carlsbad Climate Action Plan sections A5.203.1.1 daylight design and A5.203.1.2.1 energy budget. The compliance software report should designate whether indoor lighting or mechanical systems are being used to meet the 95% requirement. Light pollution reduction. Note on the plans that exterior light pollution must comply with CGC section 5.106.8. Grading and paving. Note on the plans that the grading plans shall show how site grading or a drainage system will manage all surface water flows to keep water from entering buildings. CGC Section 5.106.10. Exception: Additions/alterations that do not alter the drainage path. Moisture control. Note on the plans that landscape irrigation systems shall be designed to prevent spray on structures. Exterior entries subject to foot traffic or wind-driven rain shall be designed to prevent water intrusion into the building. CGC Section 5.407.2.2.1. Waste management. Note on the plans that the contractor must submit to the Engineering Department or other Agency that regulates construction waste management a Waste Management Plan that outlines the items listed in CGC Section 5.408.1.1. Recycling. Note on plans that a mm. of 65% of construction waste is to be recycled and/or salvaged. CGC 5.408.1. Documentation shall be provided to the enforcing agency which demonstrates compliance. CGC Section 5.408.1.4. Waste reduction. Note on the plans that 100% of trees, stumps, rocks, and associated vegetation and soils primarily from the construction will be reused or recycled. CGC 5.408.3. Recycling. Note on the plans that an identified, readily accessible area shall be provided that serves the entire building for collecting recycling, such as paper, cardboard, glass, plastics, metals, etc. CGC Section 5.410.1. Documentation. Note on the plans that a building "Systems Manual" as listed in CGC Section 5.410.2.5 shall be delivered to the building owner or representative and the facilities operator. Further, note on the plans that the "Systems Manual" shall contain the required features listed in CGC Section 5.410.2.5.1. Pollutant control. Note on the plans that during construction, ends of duct openings are to be sealed, and mechanical equipment is to be covered. CGC 5.504.3. Carlsbad CBC20 19-0602 MARCH 20, 2020 11. Pollutant control. Note on the plans that VOC's must comply with the limitations listed in Section 5.504.4 and Tables 4.504.1, 5.504.4.1 5.504.4.2, 5.504.4.3 and 5.504.4.5 for: Adhesives, Sealants, Paints and Coatings, Carpet and Composition Wood Products. CGC 5.504.4. 12. Pollutant control. Note on the plans that mechanically ventilated buildings shall provide regularly occupied areas with air filtration media for outside and return air that provides at least a Minimum Efficiency Reporting Value (MERV) of 8. MERV 8 filters shall be installed prior to occupancy. CGC Section 5.504.5.3. 13. Pollutant control. Note on the plans that where outdoor areas are provided for smoking, such areas are prohibited within 25' of building entries, windows and outdoor air intakes. Signage shall be posted to inform occupants of the prohibitions. CGC Section 5.504.7. 14. Environmental comfort. Note on the plans that wall and floor assemblies separating tenant spaces (and tenant spaces from public spaces) shall have an STC of at least 40. CGC Section 5.507.4.3. 15. Environmental comfort. Wall and roof assemblies exposed to noise sources shall have an STC rating of at least 50, with exterior windows having a minimum STC of 40 in the following locations, per CGC Section 5.507.4.1: Within the 65 CNEL noise contour of a freeway, railroad or industrial source, as determined by the jurisdiction's Noise Element of the General Plan. Within the 65 CNEL noise contour of an airport. C) Note on the plans whether or not this addition or tenant improvement is located within the areas listed above. 16. Outdoor air quality. Note on the plans that installations of HVAC, refrigeration and fire suppression systems will not contain CFC's or Halons, per CGC 5.508.1. 17. Indoor water use. For building additions in excess of 50.000 sq. ft. show on the site utility plan separate sub-meters per CGC Section 5.303.1 for the following: (a) Each leased or owned space that consumes more than 100 gal/day (b) Tenant spaces containing laundry, cleaners, restaurant, medical/dental office, laboratory or beauty/barber shops. 18. Water reduction. Show on the plans the following maximum fixture flow rates from the table below. Revise general notes, plumbing plans, etc. to match. CGC 5.303. MAXIMUM FIXTURE FLOW RATES FIXTURE TYPE MAXIMUM FLOW RATE Water closets 1.28 gallons/flush Urinals (wall mounted) 0.125 gallons/flush Urinals (floor mounted) 0.5 gallons/flush Lavatory faucets-nonresidential 0.5 gpm @60 psi Kitchen faucets 1.8 gpm @ 60 psi Metering faucets 0.2 gallons/cycle 19. Note on the plans that prior to final inspection the licensed contractor, architect or engineer in responsible charge of the overall construction must provide to the building department official written verification that all applicable provisions from the Green Building Standards Code have been implemented as part of the construction. CGC 102.3. PLUMBING AND MECHANICAL COMMENTS PLAN REVIEWER: Connor Reuss SET: II NOTE: Please address all bolded comments belowJ PLUMBING (2016 CALIFORNIA PLUMBING CODE) Carlsbad CBC20 19-0602 MARCH 20, 2020 On sheet P-I was provided upon this submittal. Please provide updated sheets P- 0 & P.2 that address the following comments: Sink S-4 is shown within the plumbing floor plan on sheet P-I yet is not shown within the fixture schedule. Please correct. Please correct sheet P-0 to state that all domestic (i.e. potable) hot water piping will have a minimum insulation for the following pipe sizes: 1/2P pipe (h/21 insulation); W pipe (1" insulation); I"- I V pipes (1 1/2 insulation); 2" pipes are larger (2" insulation). CPC 609.11 & ES 150.00) Please show the location of the required mop/service sink per CPC Table 422.1. Make sure to specify it within the fixture schedule. Sheet P-2 shows the existing water heater within Procedure #1. Please address. MECHANICAL (2016 CALIFORNIA MECHANICAL CODE) Please add M-3 to the index on title sheet. Janitor closets require an exhaust system per CIVIC Table 403.7. Please provide. To speed up the review process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, etc. Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Connor Reuss at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. - EtGil A SAFEbuilt'Company DATE: 1/22/2020 JURISDICTION: Carlsbad PLAN CHECK #.: CBC2019-0602 SET: I PROJECT ADDRESS: 2020 Cassia Rd. #103 U APPLICANT U JURIS. PROJECT NAME: Dr. Stephen Dent Tenant Improvement EJ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. El The applicant's copy of the check list has been sent to: EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Avent Design Telephone #: Date contacted: (by: ) Email: aventdesign©cox.net Mail Telephone Fax In Person LI REMARKS: By: Jason Pasiut Enclosures: EsGil 12/30/2019 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad CBC20 19-0602 1/22/2020 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK #.: CBC2019-0602 OCCUPANCY: B TYPE OF CONSTRUCTION: Ill-B ALLOWABLE FLOOR AREA: complies SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 12/26/2019 DATE INITIAL PLAN REVIEW COMPLETED: 1/22/2020 FOREWORD (PLEASE READ): JURISDICTION: Carlsbad USE: Medical Office ACTUAL AREA: 3,721sf STORIES: 1 HEIGHT: unchanged OCCUPANT LOAD: 38 DATE PLANS RECEIVED BY ESGIL CORPORATION: 12/30/2019 PLAN REVIEWER: Jason Pasiut This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2016 CBC, which adopts the 2015 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CBC20 19-0602 1/22/2020 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. BUILDING AND LIFE SAFETY REQUIREMENTS Each sheet of the plans must be signed by the person responsible for their preparation, even if there are no structural changes. California State Law. a) The applicant needs to sign page 6 of the Climate Action Plan document. Is this facility a licensed clinic, or free-standing building under a hospital licensed by the California Department of Public Health? (OSHPD-3 requirements in CBC Chapter 12 may apply) ACCESSIBILITY Show on the plans the sales and service counter section that is 36" in length with a maximum height of 34 inches. Show also the clear floor space for forward or parallel approach. Section 116-904.4.1. 2. Check writing surfaces shall be 28" minimum and 34" maximum above the floor. Section 116-904.3.3. Show on the plans that 5% of the exam room sinks comply with 116-606 for forward approach. Per Section 11 B-804, non-commercial kitchen sinks (such as at employee break rooms, etc.) shall provide the following: A clear floor space at least 30"x 48" shall be provided for forward approach and shall be on an accessible route. The clear space shall extend a maximum of 19" underneath the sink. Section 11 B-606.2. The accessible sink shall be mounted with the counter or rim no higher than 34" above finish floor. Knee clearance that is at least 27" high, 30" side and 19" underneath the sink shall be provided. Hot water and drain shall be insulated or Carlsbad CBC20 19-0602 1/22/2020 otherwise configured so as to protect against contact. There shall be no sharp or abrasive surfaces under the sink. Section 116-606. c) Faucet controls and operating mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. Lever operated, push-type and electronically controlled mechanisms are acceptable. Self-closing valves are allowed if the faucet remains open for at least 10 seconds. Section 11B-606.4. FRAMING I CEILING Provide details for the rated wall in-fill at the new radius wall section. A2 Provide suspended ceiling connection details at the interior partitions. A3 NON-RESIDENTIAL GREEN BUILDING STANDARDS (Alterations) The California Building Standards Commission (BSC) has adopted the Green Building Standards Code and must be enforced by the local building official. The Green Building Standards apply to nonresidential additions or tenant improvements throughout California. These standards apply to nonresidential additions of 1.000 sq. ft. or larger or alterations (tenant improvements) with a value of $200,000 or more. CGC Section 301.3. Provide a sheet on the plans labeled "Green Building Code Requirements" and include the following notes as applicable. Provide documentation with any applicable details that will show compliance with the Carlsbad Climate Action Plan sections A5.203.1.1 daylight design and A5.203.1.2.1 energy budget. The compliance software report should designate whether indoor lighting or mechanical systems are being used to meet the 95% requirement. 2. Light pollution reduction. Note on the plans that exterior light pollution must comply with CGC section 5.106.8. Grading and paving. Note on the plans that the grading plans shall show how site grading or a drainage system will manage all surface water flows to keep water from entering buildings. CGC Section 5.106.10. Exception: Additions/alterations that do not alter the drainage path. Moisture control. Note on the plans that landscape irrigation systems shall be designed to prevent spray on structures. Exterior entries subject to foot traffic or wind- driven rain shall be designed to prevent water intrusion into the building. CGC Section 5.407.2.2.1. Waste management. Note on the plans that the contractor must submit to the Engineering Department or other Agency that regulates construction waste Carlsbad CBC20 19-0602 1/22/2020 management a Waste Management Plan that outlines the items listed in CGC Section 5.408.1.1. Recycling. Note on the plans that a minimum of 65% of construction waste is to be recycled and/or salvaged. CGC 5.408.1. Documentation shall be provided to the enforcing agency which demonstrates compliance. CGC Section 5.408.1.4. Waste reduction. Note on the plans that 100% of trees, stumps, rocks, and associated vegetation and soils primarily from the construction will be reused or recycled. CGC 5.408.3. Recycling. Note on the plans that an identified, readily accessible area shall be provided that serves the entire building for collecting recycling, such as paper, cardboard, glass, plastics, metals, etc. CGC Section 5.410.1. Documentation. Note on the plans that a building "Systems Manual" as listed in CGC Section 5.410.2.5 shall be delivered to the building owner or representative and the facilities operator. Further, note on the plans that the "Systems Manual" shall contain the required features listed in CGC Section 5.410.2.5.1. Pollutant control. Note on the plans that during construction, ends of duct openings are to be sealed, and mechanical equipment is to be covered. CGC 5.504.3. Pollutant control. Note on the plans that VOC's must comply with the limitations listed in Section 5.504.4 and Tables 4.504.1, 5.504.4.1 5.504.4.2, 5.504.4.3 and 5.504.4.5 for: Adhesives, Sealants, Paints and Coatings, Carpet and Composition Wood Products. CGC 5.504.4. Pollutant control. Note on the plans that mechanically ventilated buildings shall provide regularly occupied areas with air filtration media for outside and return air that provides at least a Minimum Efficiency Reporting Value (MERV) of 8. MERV 8 filters shall be installed prior to occupancy. CGC Section 5.504.5.3. Pollutant control. Note on the plans that where outdoor areas are provided for smoking, such areas are prohibited within 25' of building entries, windows and outdoor air intakes. Signage shall be posted to inform occupants of the prohibitions. CGC Section 5.504.7. Environmental comfort. Note on the plans that wall and floor assemblies separating tenant spaces (and tenant spaces from public spaces) shall have an STC of at least 40. CGC Section 5.507.4.3. Environmental comfort. Wall and roof assemblies exposed to noise sources shall have an STC rating of at least 50, with exterior windows having a minimum STC of 40 in the following locations, per CGC Section 5.507.4.1: a) Within the 65 CNEL noise contour of a freeway, railroad or industrial source, as determined by the jurisdiction's Noise Element of the General Plan. Carlsbad CBC20 19-0602 1/22/2020 Within the 65 CNEL noise contour of an airport. Note on the plans whether or not this addition or tenant improvement is located within the areas listed above. Outdoor air quality. Note on the plans that installations of HVAC, refrigeration and fire suppression systems will not contain CFC's or Halons, per CGC 5.508.1. Indoor water use. For building additions in excess of 50.000 sq. ft. show on the site utility plan separate sub-meters per CGC Section 5.303.1 for the following: (a) Each leased or owned space that consumes more than 100 gal/day (b) Tenant spaces containing laundry, cleaners, restaurant, medical/dental office, laboratory or beauty/barber shops. Water reduction. Show on the plans the following maximum fixture flow rates from the table below. Revise general notes, plumbing plans, etc. to match. CGC 5.303. MAXIMUM FIXTURE FLOW RATES FIXTURE TYPE MAXIMUM FLOW RATE Water closets 1.28 gallons/flush Urinals (wall mounted) 0.125 gallons/flush Urinals (floor mounted) 0.5 gallons/flush Showerheads 1.8 gpm @ 80 psi Lavatory faucets-nonresidential 0.5 gpm @60 psi Kitchen faucets 1.8 gpm @ 60 psi Metering faucets 0.2 gallons/cycle Note on the plans that prior to final inspection the licensed contractor, architect or engineer in responsible charge of the overall construction must provide to the building department official written verification that all applicable provisions from the Green Building Standards Code have been implemented as part of the construction. CGC 102.3. PLUMBING AND MECHANICAL COMMENTS PLAN REVIEWER: Connor Reuss SET: I ARCHITECTURAL P&M ITEMS Please note on the Title sheet that this is not an OSHPD III review. Specify if any walls within the tenant space are required to be fire rated. PLUMBING (2016 CALIFORNIA PLUMBING CODE) Carlsbad CBC20 19-0602 1/22/2020 Please specify on sheet P-I that RR #102 is an existing ADA restroom as stated within the architectural sheets. Sink S-4 is shown within the plumbing floor plan on sheet P-i yet is not shown within the fixture schedule. Please correct. Please correct sheet P-0 to state that all domestic (i.e. potable) hot water piping will have a minimum insulation for the following pipe sizes: 1/2" pipe (W insulation); 341' pipe (1" insulation); 1"- 1 1,4" pipes (1 1,4" insulation); 2" pipes are larger (2" insulation). CPC 609.11 & ES 150.00) The 2" waste line that connects sinks from Exam #1, Exam #2, Exam #3, Exam #4, Exam #7, Procedure #1 and Break Room is undersized. Please upsize to a 3". Please show the location of the required mop/service sink per CPC Table 422.1. Make sure to specify it within the fixture schedule. Sheet P-2 shows the existing water heater within Procedure #1. Please address. MECHANICAL (2016 CALIFORNIA MECHANICAL CODE) Specify compliance with CMC 603.4.1 for length limitations for factory made flexible air ducts (5') and use (not to be used for rigid elbows or fittings). Please distinguish , HP-2 and EF-I on sheet M2.0. They are difficult to find. Janitor closets require an exhaust system per CMC Table 403.7. Please provide. Provide a mechanical roof plan showing the location of, HP-2 and the termination of EF-1. Make sure a clearance of 10' from the forced air intakes are maintained. Review with the architect the locations that require (fire/ceiling radiation/or fire/smoke) dampers and identify installations on the mechanical plans themselves. Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Connor Reuss at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. END OF REVIEW To speed up the review process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Carlsbad CBC2019-0602 1/22/2020 Have changes been made to the plans not resulting from this correction list? Please indicate: U Yes U No The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Jason Pasiut at Esgil. Thank you. Carlsbad CBC2019-0602 1/22/2020 [DO NOT PAY-. THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK #.: CBC2019-0602 PREPARED BY: Jason Pasiut DATE: 1/22/2020 BUILDING ADDRESS: 2020 Cassia Rd. #103 BUILDING OCCUPANCY: B BUILDING PORTION AREA (Sq. FL) Valuation Multiplier Reg. Mod. VALUE ($) TI 3721 64.72 240,823 Air Conditioning Fire Sprinklers TOTAL VALUE 240,823 Jurisdiction Code 1cb By Ordinance 1997 UBC Building Permit Fee 1997 UBC Plan Check Fee Ni Type of Review: P' Complete Review r Structural Only T- Repetitive Fee FE Repeats p. r Other r Hourly EsGil Fee I F I $732.301 Comments: Sheet 1 of 1 SAN DIE C 0 REGIONAL OI!FI4E USE ONLY RECORD 10$__________ ______ HAZARDO PS MATERIALS PLAN CHECK# i14z4? }-34MJ-Ob2.7 BP I I QUES IONNAIRE B Name .Jusines Contact _oe fKrn* _ Jf Telephoned ot1q- 00 State Zip Code Al Proje rab ct _ Ca ($( 10 ' Plan File# Mailing Address Project Contact , City bad_d l ' YipCod Applicant E-mail Telephone I The following cifiestions represent the facility's activities, NOT the specific project jiet$ic ption. PART I FIRE DEPARTMENT — HAZARDOUS MATERIALS DIVISION OCCUPANCY CLASSIFICATION (not reulM for nrelacts within the City of San Ulepo): Indicate by circling ins item, wnetneri your business Will use, process, or store any OT the TOliOWlfl9 nazaros lini itenais. it any or inc items are circiea, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Occupancy Rating: Fac4lty's Square Footage (including proposed project): Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 13 Corrosives Compressed Gases 6. Cddizers 10. Cryogenics 14 Other Health Hazards Flammable/Combustible Liquids 7. Pj,rophoncs 11. Highly Toxic or Toxic Materials 5 None of These. 4. Flammable Solids 8. Uhstable Reactives 12. Radloactives . I Call (858) 565-6700 prior to the issuance of a FEES ARE REQUIRED Project Comi YES NO 0 go Is your business listed on t (j' 0 Will your business dispose i 0 @ Will your business store or pounds and/or 200 cubic Ic 0 I' Will your business store or I . 0 ER Will your business use an a 0 19' Will your business store or I 0 l' Will your business use or in 6. 0 1!' Will your business store pet ilding permit .1 - (E1 oiqp. oIjv,nlCaA tion Date: L 1a5lO Expected lteofOccupan'b9: 5Jt (for new construction or remodeling proct) reverse side of this form? (check all that apply). Hazardous Substances or Medical Waste in any amount? ndle Hazardous Substances in quantities greater than or equal to 55 geliobs 500 Is carcinogens/reproductive toxins in any quantity? ig or install an underground storage tank? I Is Regulated Substances (CalARP)? a Hazardous Waste Tank System (Title 22, Article 10)? im in tanks or containers at your facility with a total facility storage c11 paçity equal to V the answer to any or Inc Diego, CA 92123. 0 CalARP Exempt Date Initials CaIARP Required Date Initials CalARP Complete Date Initials to identify the majority of air pollution issues requirements contact APCD. Residences as dwelling units; townhomes; condos: mixed-cc YES NO (' 0 Will the project disturb 160 0 (I Will any load supporting SD rV (ANSWER ONLY IF QUES Technician? 0 Qf (ANSWER ONLY IF QUES may be required 10 workin 0 13/ Will the project or associatl 0 0 (ANSWER ONLY IF INTROL_DISTRICT_(APCD): Any YES answe4requires iM 66-2650). -No stamp required If 01 Yes gj Q Yes ind 04 ning stage. Projects may require additional meures not ide exempt, except - those with more than one bui1ing' on the use; deliberate burns; residences forming part oqa larger proj s feet or more of existing building materials? ii members be removed? Notification may be 1 or 2 IS YES) Has an asbestos survey been ON 3 IS YES) Based on the survey results, will the projectPMiTar lays prior to commencing asbestos removal. construction equipment etTlit air contaminants? See the reverse side errnits.Ddf) for typical equipment requiring an APCD permit. ON 5 IS YES) Will the project or associated construction equipment 1 HAeADHW24 Old Gr4ie Road, San following question4 are intended tfèse questions. For cpnprehensive y: single buildings with lore than four .1 xueggf gas A small futbuildings.J ua(u) p or to commencing demoIlon. A bestos Consultant or Siterurveillance mi or APCD factsheet istd within 1.000 feet of a school Briefly desciIbe business oaok._ Name of or or Author that to the best of my knowledge and Briefly describe proposed project: responsesmade herein are true endco,'et. ,,_/_ 620 FOR OFFICAL USE ONLY: FIRE DEPARTMENT OCCUPANCY ov. DATE: RTIRR INFORMATION REM RED RELEASED FOR BUILDING PERMIT BUT NOT FOR occupANcY RELEASED FOR OCCUPANCY 4 APCD COUNTY-I4MD _ ..APCDi. C NTY-HMD APCD REVIEWED . G APR 012020 02- 03 ZDZD CITY o. LSBAD BU1-DN3" . - oiWjX exempts ousjnessu trum cumsuturiu UI uputu.y U r LUUUuU UU'' .......... V• •••••• ...J _•.•. HM-9171 (08/15) County of San Die —0 ,H — Hazardous Materials Division yewya o;jncE*s (C f CLIMATE ACTION PLAN Càrltd CONSISTENCY CHECKLIST eve,opmenr,erv,ces Building Division 1635 Faraday Avenue (766) 602-2719 www.carlsbadca.gov PURPOSE This. checklist is intended to requirements apply to their prc necessary to supplement the full compliance with CAP ordir to comply with energy-related specified by the ordinances. ;t building permit applicants identify which Climt 4ct'ion Plan (CAP) ordinance The completed checklist must be included in the b4iildirg permit application. It may be eted checklist with supporting materials, calculatios o certifications, to demonstrate requirements. For example, projects that propose r equire a performance approach ures will need to attach to this cheôklist separate $alIations and documentation as N :. ' '. t.t. -.tt .'tw$&fl.'fl 'kZ.O.; .t&t. . . •;r., . :• Patio .4 CtC4t-t. ..'e A A•èJ !lt .!. .A . thu . .ujth ..Vt.' .............t.tt.:.,. Decks + PME (w/o panel upgrade) + Pool 4 If an item in the checklist is an explanation must be pr A Details on CAP ordinance 4 A CAP Building Plan temr completed to demonstrate download the latest form. ned to be not applicable to a project, or is less than d to the satisfaction of the Building. Official. rernents are available on the city's website. (form B-55) shall be added to the title page all bt ct compliance with the CAP ordinances. Refer to ti required by ordinance, g plans. This template shall be pi ding application webøaqe and Project Name/Building Permit No.: Property Addréss/APN: Applicant Name/Co.: •9) r/1- Applicant Address: Contact Phone: BP No.: P&vit 7 Css 1,CL _10 iu ,v' I ,. i,- ..' ,. Contact Email: Contact information of person dompleting this checklist (if different than above): Name: . Contact Phone: Company name/address: . Contact Email: Applicant Date: B50 Page 1 016 Revised 08/19 City of Carlsbad Climate I Lction Plan Consistency Checklist Use the table below to determine which sections of the Ordinance Compliance checklisi arel applicable to your project. - For alterations and additions to existing buildings, Building Permit Valuation (BPV $ 2 g0, v:. i ':.::. •-. .•:; O Residential :' •- Lw dse 11tgh.nse m 20% of Its conditioned floor • -. areaiesidentialbse _______ New con 2A,3A, I IB,2B, 4A 3B, 4A Additions and alterations: BPV < $60,000 N/A N/A All residential additions apd alterations BPV k $60,000 1A 4A 4A 1-2 family dwellings and iownlouses with attached garages Electrical service panel upgrade only ' only *Mul4j family dwellings oily *tere interior finishes are removed BPV 2:$200,000 1A, 4A* lB. 4A and significant site work ind upgrades to structural and mechanical, electrical, aar plumbing stems are proposed Nonresidential , - 4 O New construction [_IB, 2B, 38.4B and 5_ - _.Alterations: - ' • ' BPV k$200,000 or add Mons a 1,000 -square feet 0 BPV 2t $1,000,000 113, 2B, 5 Building alterations of xisting gross floor area 2,000 sq. ft. new roof iddition 28,5 1 also applies if BPV 200000 1:e n Please refer to Carlsbad Muniapal Cod (CMC) sections 18.21.155 and 18.30.190, and the California Green Bui4ing Standards Code (CALGreen) for more information when completing this action. A 0 Residential addition oralti ation?$60,000 building pemiitvaluation. 0 tIA________________ See CIIIC section 18.30.19 . 0 Ejcep4n: Home energy scorek7 (attaCh ertification) Year Built Sin le-family Requirements Multi-family Rec$iirenents Before 1978 Sal tOfl 0 C ci sealing 0 Attic insulation 0 Cool roof 0 Attic insulation O • and d later Sel atone: DI hung package 0 Water heating Package Between and nd 1991 - Select one: 0 Duct sealing 0 Attic insulation 0 Cool roof 1992 and later Seled one: Cl lighting package 1 0 Water heating package Nonresidenttal new cons iction oraItei1ions? $200,000 building pennit valuation, additions 1,000squai feet 0 NIA Updated 8/15/2019 3 . City of Carlsbad Climate A tion Plan Consistency Checklist See CMC 18.21.155 and CAL 3reen Appendix A5, Division A5.2 - Energy Efficiency. A5203.1.1 Choose one: 0.1 utdoor lighting 0.2 Warehouse dock seal doors 0,3 Restaurant service water heating comply with California Energy Codesection 140.5, as amended) 0 N14_ \,1P4 Daylight design PAR 051 aust air heat recovery A5.203.1.2.1 Choose one as applicable: Energy budget 0.90 Energy budget 0 Nh A5211.1" . ()) 0 On-site renewable energy NJ A5.211.3 0 Green power (if offered by local util y provider, 50% minimum renewable sources) A5.212.1 0 Elevators and escalators . t5.2)3.1 ~ Steel framing * duile--; hotels/motels and high-rise re dential buildings For alterations a $1,000,000 BPV and iffecting >75% existing gross floor area, or alterations that add 2,000 SqL arelfi (of new roof addition: comply with CIVIC 18.30.130 instead. • _____________________________________ ___________________ 0 Residential new constructio (for low.dse residential building permit applications submitted Refer to 2018 California Energy Code section 150.1( 14 for requirements. Notes: 1) High-rise residential buildings are s et to nonresidential photovoltaic requirement (2B below) insti id. 2) If project includes installation of an electric heat pump water eate pursuant to CIVIC 18.30.150(B) (high-rise residential) or I IL3 0.170(B) (low-rise residential), increase system size by .3kWdc if PV ff$ option is selected. Floor Plan ID (use additional CFA #d.u. Calculated kWdc* --1-Excep on sheets if necessary) Total System Size: kWdc - - kWdc-(CFAx.572)I1,000+(1.15xId. .) ¶omnila calculation where CFA = condit onal floor area, #du = number of dwellings per plan type If proposed system size is less than calc lated size, please explain. 0 Nonresidential new constru (ion or alterations ?$1,000,000 BPV and affecting V50/6 existing floor a*, addition that increases roof area by ?2,000 square feet F lease refer to CIVIC section 18.30.130 when completing this section. I4ote: This section also applies to high-rise residential and ho tlmotel buildings. Choose one of the following ff ethods: . . I] Gross Floor Area (GFA) r lethod GFA: Min. System Size: kWdc If< 10,000s.f. En er: 5 kWdc If 10,000s.f. cal ulate: 15 kWdc x (GFNI0,000) **Round buildings' e factor to nearest tenth, and round system size to nearest W iolo lumber. 0 Time- Dependent Valuatic n Method T Updated 8/15/2019 City of Carlsbad Climate P4ction Plan Consistency checklist A. D Residential New con truction and major alterations Please refer to Carlsbad 0 linance CMC section 186,21'.140wh en completing this seIt!. One and two-family res entiàldwelliñg 6rtOwnhôuse with attahedgarage : 0 One EVSE Ready p rking space required .0 Exception: Multi-family residential: 0 Exception:_____ - Total Parking Spaces i Proposed EVSE Spaces = Capable Ready lnstaect Total Calculations: Total EVSE spaces : .10 x Total parking (rounded up to nearest whole number) EVSE lnstaffed= I tal.EVSE Spaces x.50 (rounded up to nearest whole number) EVSE other= Total ".VSE spaces - EVSE Installed (EVSE.other may I Capable,5 1Ready" or"lnstaUed. ajôralterations.are (1) fOr one nd two-family dwellings and townhouses with attached garages, alterations ha a building pem'nitvaluatiàn $60,000 or include an electrical service par I upgrade; (2) for multifamily dwellings (three units 6r more without aUaded g rages), alterations have a building permit valuation a $200,000, intenorfiniS as are removed and significant site work and upgrades to structural and riedi nical, electrical, and/or plumbing systems are proposed. . . . .• B. Ne tialnewconstr tion (includes hoteIsIrnotels)..ii Exception: .._. . . .. . : Total Parking Spaces.. . EVSE. Spaces Capable Ready. 1ns11ej Total Proposed Calculation Refer to the tab! below Total Number of Parking Space provided Number of required EVSpaoes NItm of required EVSE Installed Spaces o _o- 1 o_10-25 ...• ... __.;.::;:2 . : ___1•.•..... o_26-50 . _. -- 2 o_5175 . ._._ .:6:.. I 3 o_76-100 . .9.: -- 5 o_101-150 - 6 o .151-200 . -_12 .......- .. _____17...... o 201 and over 10 percentof total -! ..i percent of Required EV Spaces Updated 8/15/2019 City of Carlsbad Climate Action Plan Consistency Checklist An approved Transportation Demand Management (TOM) Plan is required-for all nonresidential projects that hold of employee-generated ADT. City staff will use the table below bas -d on your submitted plans to determine whether or nor your pemiitreqi plan. If TOM is applicable to your permit, staff will contact the applicant to develop a site-specific 1DM plan based on the permit details. mpIoyee ADT Estimation for Various Commercial "44 e Use first 1,000 s.f 1000 I , 5J., Office (all)2 20 . 1. Res aurant .. •i•.1..• . Relil3 8 4. Ind strial . . . 4 .. 3. Ma ufacturing .. . Waehousing . .4 . I - - i Ur less otherwise noted, rates estimated from ITE Trip Ge, eration Manual, 1OEdition 2 Fcr all office uses, use SANDAG rate of 20 ADT/1 000 sf employee ADT .calculate RE tail uses include shopping centei variety store, superm arke, gyr s, pharmacy, etc. 0th or commercial uses maybe subject tospecial cor sideration Sar We caIcuIationS - . .. e: 20,450 sf . Off 20,450 sf1 1000 x 20 = 409 Employee ADT Ret II: 9,334 sf First l,000sf=8ADT 9,334 sf - 1,000 sf = 8,334 sf (8,334sf! 1,000 x4.5)+ 846 Employee ADT Acknowledgment: I acknowledge that the plans submitted m iy be subject to the City of Carisbad's Transportation Demand Managemqnt my permit require a 1DM plan and under and that an approved TDM plan is a condition Of permit issuance. Applicant Signature: . . D : Person other than Applicant to be conj Wed for TDM compliance (if applicable): Name (Printed): . . Email Address: . . I agree to be contacted should Updated 8/15/2019 6-