HomeMy WebLinkAbout2653 SAUSALITO AVE; ; CB013154; PermitJ<Ø'Q 12-26-2001 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit Permit No:C1301 3154 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 2653 SAUSALITO AV CBAD RESDNTL Sub Type: RAD Status: ISSUED 1675117400 Lot #: 0 Applied: 10/03/2001 $35,741.00 Construction Type: NEW Entered By: JM Reference #: Plan Approved: 12/26/2001 0 Structure Type: Issued: 12/26/2001 0 Bathrooms: 0 Inspect Area: MONTEGOMRY - RAD 347 SF Orig PC#: Plan Check#: Applicant: Owner: 7690 12/26/01 0002 01 02 MONTGOMERY JEFF C&SUSAN K MONTGOMERY JEFF C&SUSAN K Ct3F 323.92 2653 SAUSALITO AVE 2653 SAUSALITO AVE CARLSBAD CA 92008 CARLSBAD CA 92008 Total Fees: $503.55 Total Payments To Date: $179.63 Balance Due: $323.92 Building Permit $276.35 Meter Size Add'l Building Permit Fee $0.00 Add'I Red. Water Con. Fee $0.00 Plan Check $179.63 Meter Fee $0.00 Add'l Plan Check Fee $0.00 SDCWA Fee $0.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $3.57 PFF $0.00 Park in Lieu Fee $0.00 PFF (CFD Fund) $0.00 Park Fee $0.00 License Tax $0.00 LFM Fee $0.00 License Tax (CFD Fund) $0.00 Bridge Fee $0:00 Traffic Impact Fee $0.00 Other Bridge Fee $0.00 Traffic Impact (CFD Fund) $0.00 BTD #2 Fee $0.00 Sidewalk Fee $0.00 BTD #3 Fee $0.00 PLUMBING TOTAL $0.00 Renewal Fee $0.00 ELECTRICAL TOTAL $20.00 Add'l Renewal Fee $0.00 MECHANICAL TOTAL $24.00 Other Building Fee $0.00 Housing Impact Fee $0.00 Pot. Water Con. Fee $0.00 Housing InLieu Fee $0.00 Meter Size Master Drainage Fee $0.00 Add'l Pot. Water Con. Fee $0.00 Sewer Fee $0.00 Red. Water Con. Fee $0.00 Additional Fees $0.00 TOTAL PERMIT FEES $503.55 FINAL APPROVAL Inspector: Date: Clearance: NOTICE: Please take NOTICE that approval of your project includes the'Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "feeslexactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capadily changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTM61T 1635 Faraday Ave., Carlsbad, CA 92008 - 2 S6 Address (include Bldg/Suite #1 Business Narr FOR OFFICE USE ONLY PLAN CHECK NO EST. VAL. Plan Ck. D Validated 31slej Legal Description Lot No. Subdivision Name/Number Unit No. Phase No. Total # of units Assessor's Parcel # Existing Use Proposed Use 1370 10/03/01 fl00 01 02 Description of Work - . SQ. FT. #of Stories # of Bedrooms COf— .pf Bathroom 17963 - 111 -- CONTACjS0jiljif differejppjfgjt), _. Name N1 Address - City State/Zip - Telephone II Fax# OiT Name Address City State/Zip Telephone # L PROPERYY OWNER ' 11 7- :_ Name \) ) Address City State/Zip Telephone # IIQLPMPANY NAME 711. MKM~ (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($50011. Name Address City State/Zip Telephone # State License # License Class City Business License # Designer Name Address City State/Zip Telephone State License # Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance' carrier and policy number are: Insurance Company Policy No._____ Expiration Date__________________ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($1001 OR LESS) CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, Interest and attorney's fees. SIGNATURE - DATE I heieby affirm that I am exempt from the Contractor's License Law for the following reason: owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 I am exempt under Section Business and Professions Coe for this reason: I personally plan to provide the major labor and materials for construction of the proposed property ,covement. 0 YES gNo I (have / have not) signed an application for a building permit for the proposed work. /7 I have contrated.with the following person (firm) to provide the proposed constructjon (cIude name / address / phoqeumbe (,°t- C..-1 / contractors license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address / phone number I type of work): - . PROPERTY OWNER SIGNATURE _ . DATE .C) -' —C) S. [COMPLETE ws_sjjpjoi OflE TT Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES 0 NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES 0 NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 0.7~n- M-0., .-.. -I E CONSTRU.CTION-,LENDIN.GWd ..Jr . •.. - I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME . LENDER'S ADDRESS_______________________________________________________ APPLIcCEFCATIONJ . .TT. . I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cite of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL. LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 18ft days (Section 106.4.4 Uniform Building Code). APPLICANT'S SIGNATURE DATE 'Q WHITE: File YELLOW: Applicant PINK: Finance City of Carlsbad Bldg Inspection Request For: 05/01/2003 Permit# CB013154 Title: MONTEGOMRY - RAD 347 SF Description: Type: RESDNTL Sub Type: RAD Job Address: 2653 SAUSALITO AV Suite: Lot 0 Location: APPLICANT MONTGOMERY JEFF C&SUSAN K Owner: MONTGOMERY FAMILY TRUST 06-17-98 Remarks: Total Time: Inspector Assignment: PY Phone: 7607202343 Inspector: Requested By: SUSAN Entered By: CHRISTINE CD Description Act Comment 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Associated PCRs/CVs Inspection History Date Description Act Insp Comments 09/09/2002 17 Interior Lath/Drywall AP PY 09/09/2002 18 Exterior Lath/Drywall AP PY 09/03/2002 16 Insulation AP PY 08/30/2002 14 Frame/Steel/Bolting/Welding AP PY 08/30/2002 18 Exterior Lath/Drywall AP PY 08/12/2002 13 Shear Panels/HD's AP PY 08/08/2002 13 Shear Panels/HD's AP PY 05/02/2002 15 Roof/Reroof AP RB ROOF NAILING ONLY 05/01/2002 15 Roof/Reroof CO RC WRONG NAILS (8 GALVANIZED) AND DEEP PENETRATIONS 04/02/2002 11 Ftg/Foundation/Piers AP AC SPECIAL SOILS REPORT FILED 03/27/2002 11 FtglFoundation/Piers NA AC SEE PETE ABOUT 24HOUR SPEC. INSP. I 'NNop ka P.O. Box 1195 INUll /4 (619) 3-OO6O Lakeside, CA 920 To 11J4/ AJgs 77 Date -277Jd- /;-eT77AJ G Wf,4-iTZ7, :EsGiI Corporation In Partnership with Government for Building Safety DATE: 12/18/01 D_LICANT JURISDICTION: Carlsbad PtANEVIEWER 0 FILE PLAN CHECK NO.: 01-3154 SET: IV PROJECT ADDRESS: 2653 Sausalito Ave. PROJECT NAME: Montgomery SFD Addition The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. r El The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. El The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ED The cpeck list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. El The applicant's copy of the check list, is enclosed for the jurisdiction to forward to the applicant contact person. El The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. El Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Date contacted: (by: ) Mail Telephone Fax In Person El REMARKS: Telephone #: Fax #: By: Kal Tumalieh Enclosures: Esgil Corporation El GA MB DEJ DPC Log tmsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 7. 9 __ EsGil Corporation In Partnership with Government for Building Safety DATE: 11/27/01 U APPLICANT JURI JURISDICTION: Carlsbad U REVIEWER U FILE PLAN CHECK NO.: 01-3154 SET: III PROJECT ADDRESS: 2653 Sausalito Ave. PROJECT NAME: Montgomery SFD Addition L The plans transmitted herewith have been corrected where necessâty and substantially comply with the jurisdiction's building codes. 0 The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: 2355 Terraza Ribera Carlsbad, CA 92009 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Fred Dinger Telephone #: (760) 431-0315 Date contacted: t i /z 7 /o, (by: Fax #: (760) 918-0759 Mail ,,telephone Fax " In Person LI REMARKS: By: Kal Tumalieh Enclosures: Esgil Corporation EJGA EMB DEJ F1 PC 11/14/01 trnsmtLdot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Jr 'S Carlsbad 01-3154 11/27/01 NOTE: The item numbers listed below refer to the numbers from the previous list. These items have not been adequately addressed. The notes in bold at the end of each item are to emphasize the remaining problem. Please Drovide a response list stating where each item has been addressed on the plans. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635. Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. STRUCTURAL 15. Note on the plan the soils classification, whether or not the soil is expansive and note the allowable bearing value. Section 106.3.3. Soil report shall include soil expansive index. The requested information was not submitted. 20. Provide a clear roof-farming plan. Please show orientation of all roof rafters and specify the size of ridge beams on roof framing plan. c) Show rafter ties. Rafter ties shall be spaced not more than 4 feet on center and be just above the ceiling joists, where rafters and ceiling joists are not parallel. Section 2320.12.6.At bedroom #2. The requested information was not submitted. Provide calculation to justify the adequacy of ledger connection of new construction to existing detail (A/A-1). Justify the adequacy of 2-16d @ 32 " 0/C. to carry new roof dead and live load. The requested information was not submitted. Please revise the length of second floor shear along grid lines A, 1,2. Lengths used in calculation do not agree with plans. The requested information was not submitted. Carlsbad 01-3154 11/27/01 Please clarify the lateral design of second floor along grid line B. Lateral design is very difficult to follow. . The requested information was not submitted. Provide lateral design for first floor shear walls along grid lines A, 13,1 and 2. Additional corrections may follow. . The requested information was not submitted. Please clarify how second floor shear wall lateral loads will be distributed to first floor shear walls per UBC section 1630.5. Please show where in calculation you address that. Additional corrections may follow. . The requested information was not submitted. PLEASE SCHEDULE AN APPOINTMENT TO GO OVER THE STRUCTURAL CORRECTIONS. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes L3 No L3 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Kal Tumalieh at Esgil Corporation. Thank you. EsGil Corporation In Partnership with Government for Building Safety DATE: 11/07/01 13LAPPUCANT JURI JURISDICTION: Carlsbad u PLAN REVIEWER 0 FILE PLAN CHECK NO.: 01-3154 SET: II PROJECT ADDRESS: 2653 Sausalito Ave. PROJECT NAME: Montgomery SFD Addition fl The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: 2355 Terraza Ribera Carlsbad, CA 92009 El Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Fred Dinger Telephone #: (760) 431-0315 Date contacted: i iq/o, (by:fac) Fax #: (760) 918-0759 Mail —lelephone In Person El REMARKS: By: Kal Tumalieh Enclosures: Esgil Corporation El GA [:1 MB EJEJ [I PC 10/30/01 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 01-3154 11/07/01 NOTE: The item numbers listed below refer to the numbers from the' previous list. These items have not been adequately addressed. The notes in bold at the end of each item are to emphasize the remaining problem. Please provide a response list stating where each item has been addressed on the plans. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. STRUCTURAL Note on the plan the soils classification, whether or not the soil is expansive and note the allowable bearing value. Section 106.3.3. Soil report shall include soil expansive index. The requested information was not submitted. Please specify the drawing scale for roof framing portion shown on sheet A-1 .The requested information was not submitted. 20. Provide a clear roof-farming plan. Please show orientation of all roof rafters and specify the size of ridge beams on roof framing plan. Provide calculation for ridge beams. Provide end support for ridge beams. Show rafter ties. Rafter ties shall be spaced not more than 4 feet on center and be just above the ceiling joists, where rafters and ceiling joists are not parallel. Section 2320.12.6.At bedroom #2. 23. Provide a complete second floor-framing plan. a) Please clarify are using TJI series 150 of 250. See sheet A-I. B) Specify the size of all floor beams on plans. For example beam B2. Carlsbad 01-3154 11/07/01 24. Please provide information about the existing foundation shown on detail (Width, depth, etc.) and justify the assumed allowable soil pressure for existing foundation of 2500 psf. Add the content of comment 25on plans. 27. Show location for required posts on foundation plans for example posts P-4, P-5 and P-6. Specify the size of all new posts on plans. Provide positive connection between new addition and existing building. Provide straps from new walls at top plates to tie the existing walls. Provide strapping at second floor and roof level. Provide calculation to justify the adequacy of ledger connection of new construction to existing detail (A/A-1). Justify the adequacy of 2-16d @ 32 "0/C. to carry new roof dead and live load. The requested information was not submitted. Please revise the length of second floor shear along grid lines A, I ,2. Lengths used in calculation do not agree with plans. The requested information was not submitted. Show all required shear walls on plans. For example show the required (second) floor shear walls along grid lines (A, B, 1, 2). Please coordinate between structural calculations and plans. The requested information was not submitted. Please clarify the lateral design of second floor along grid line B. Lateral design is very difficult to follow. . The requested information was not submitted. Provide lateral design for first floor shear walls along grid lines A, 13,1 and 2. Additional corrections may follow.. The requested information was not submitted. Please clarify how second floor shear wall lateral loads will be distributed to first floor shear walls per UBC section 1630.5. Please show where in calculation you address that. Additional corrections may follow. . The requested information was not submitted. PLEASE SCHEDULE AN APPOINTMENT TO GO OVER THE STRUCTURAL CORRECTIONS. Carlsbad 01-3154 11/07/01 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes No L3 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Kal Tumalieh at Esgil Corporation. Thank you. EsGil Corporation In Partnership with Government for Building Safety a DATE: 10/12/01 JURISDICTION: Ca1sbad U PLAN REVIEWER C3. FILE PLAN CHECK NO.: 01-3154 SET: I PROJECT ADDRESS: 2653 Sausalito Ave. PROJECT NAME: Montgomery SFD Addition El The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. L11 The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department -staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: 2355 Terraza Ribera Carlsbad, CA 92009 El Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Fred Dinger L —i Telephone #: (760)431-0315 Date contacted: D f (by:13) Fax #: (760) 918-0759 MaiI.—TeIephone - Fax - In Person LI REMARKS: By: Kal Tumalieh Enclosures: Esgil Corporation [:1 GA [:1 MB DEJ El PC 10/04/01 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 01-3154 10/12/01 PLAN REVIEW CORRECTION LIST. SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: 01-3154 JURISDICTION: Carlsbad PROJECT ADDRESS: 2653 Sausalito Ave. FLOOR AREA: Room addition (347) DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 10/12/01 FOREWORD (PLEASE READ): STORIES: Two HEIGHT: 21 Ft. (App. per UBC) DATE PLANS RECEIVED BY ESGIL CORPORATION: 10/04/01 PLAN REVIEWER: Kal Tumalieh This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California. law mandates that residential construction comply with the 1998 edition of the California Building Code (Title 24), which adopts the following model codes: 1997.UBC, 1997 UPC, 1997 UMC and 1996 NEC (all effective 7/1/99). The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any. state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section. etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad 01-3154 10/12/01 Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. When the valuation of a room addition or repair exceeds $1,000, or when sleeping rooms are created, smoke detectors shall be provided per the above, except that smoke detectors added at existing construction need only be battery powered. Section 310.9.1.2. Please add this note on plans. 2. Specify on the plans the following information for the roof materials, per Section 106.3.3: Manufacturer's name. Product name/number. ICBO approval number, or equal. 3. Per local ordinance, a Class A roof is required. 4. Note on the plans: "Attic ventilation openings shall be covered with corrosion-resistant metal mesh with mesh openings of 1/4-inch in dimension." Section 1505.3. 5. Garage requires one-hour fire protection on the garage side of walls and ceiling common to the dwelling. Table 3-13, Section 302.4. Between existing garage and new porch. ELECTRICAL (NATIONAL ELECTRICAL CODE) 6. Show on the plan the amperage of the electrical service, the location of the service panel and the location of any sub-panels. If service is over 200 amps, submit single line diagram, panel schedule and load calculations. Are you upgrading the existing electrical service due to the new addition? Carlsbad 01-3154 10/12/01 . ENERGY CONSERVATION The regulations require a properly completed and properly signed Form CF-1 R to be either imprinted on the plans, taped to the plans or "sticky backed" on the plans, to allow the building inspector to readily compare the actual construction with the requirements of the approved energy design. Specify on the building plans all of the mandatory energy conservation requirements as listed on the enclosure titled, "Mandatory Measures Checklist". Show the make, model, type and efficiency of the space heating (or cooling) system. Is the existing FAU unit capable of heating the existing building and new addition? Note on the plans: "The manufactured windows shall have a label attached certified by the National Fenestration Rating Council (NFRC) and showing compliance with the energy calculations." At new addition. II. Cloth backed duct tape is no longer permitted to be used as the sole. connection for mechanical ducting. Note on the plans that duct tape, as a minimum, meeting the requirements of ULI8I, 181 A, or 181 B, shall be used or additional duct attachment devices such as tie wraps or mastic will be required for installing mechanical ducting. At new addition. 12. Detail or note on the plans: "The return air plenum serving the mechanical equipment must be fully ducted from the equipment to the conditioned space. Drop ceilings, wall cavities and equipment platforms may not be used as plenums." At new addition. STRUCTURAL 13. The soils engineer recommended that he/she review the foundation excavations. Note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that: The building pad was prepared in accordance with the soils report, The utility trenches have been properly backfilled and compacted, and The foundation excavations, the soils expansive characteristics and bearing capacity conform to. the soils report." 14. Note on plans that wood shall be 6" minimum above finish grade. Section 1806.1. Revise detail (8/D-I). 15. Note on the plan the soils classification, whether or not the soil is expansive and note the allowable bearing value. Section 106.3.3. Soil report shall include soil expansive index. .ç r Carlsbad 01-3154 10/12/01 16. The following anchor bolt requirements shall apply in Seismic Zones 3 and 4, per Section 1806.6.1: The minimum nominal anchor bolt diameter shall be 5/8inch (for Seismic Zone 4 only). Note: This will require a minimum distance from the ends of sill plates to be 4-3/8" (and a maximum of 12"). Plate washers (minimum size of 2" x 2" x 3/16") shall be used on each anchor bolt. 17. Please specify the required slab on grade reinforcement on plans. revise detail (81D-1). 18. Please specify the type of epoxy and ICBO approval number. Revise detail (1/D-2). 19. Please specify the drawing scale for roof framing portion shown on sheet A-I. 20. Provide a clear, roof-farming plan. Please show orientation of all roof rafters and specify the size of ridge beams on roof framing plan. 21. Show nailing will be in compliance with Table 23-I1-13-I. 22. Specify all header sizes for openings over 4' wide. Section 2320.11.6. Please specify the size of second floor headers on framing plans. 23. Provide a complete second floor-framing plan. 24. Provide a detailed calculation for floor beam B-I and B-6. Provide bending moment and deflection calculation or provide copy of manufacturer reference tables used in design. 25. Please provide information about the existing. foundation shown on detail (Width, depth, etc.) and justify the assumed allowable soil pressure for existing foundation of 2500 plf. 26. Please specify the required reinforcement, depth of concrete pad foundation and provide detail. For example for post P-2. 27. Show location for required posts on foundation plans for example posts P-4, P-5 and P-6. 28. Please clarify the required foundation for posts PA and P-3. Posts are supported by new foundation, while calculation page P-2. Specify that post are supported by existing continuous foundation (12" x14"). Please clarify! Carlsbad 01-3154 10/12/01 Specify nail size and spacing for all shear walls, floor and roof diaphragms. Indicate required blocking. Maintain maximum diaphragm dimension ratios. Sections 2315 and 2513. A) Please provide information about roof sheathing. Provide positive connection between new addition and existing building. Provide straps from new walls at top plates to tie the existing walls. Provide calculation to justify the adequacy of ledger connection of new construction to existing detail (A/A-1). Justify the adequacy of 2-16d @ 32 " 0/C. to carry new roof dead and live load. Revise detail (A/A-1). Shows shear transfer detail. At roof level. Please revise the length of. second floor shear along grid lines A, 1,2. Lengths used in calculation do not agree with plans. Show all required shear walls on plans. For example show the required (second) floor shear walls along grid lines (A, B, 1, 2). Please coordinate. between structural calculations and plans. Please clarify the lateral design of second floor along grid line B. Lateral design is very difficult to follow. Provide lateral design for first floor shear walls along grid lines A, 13,1 and 2. Additional corrections may follow. Please clarify how second floor shear wall lateral loads will be distributed to first floor shear walls per UBC section 1630.5. Please show where in calculation you address that. Additional corrections may follow. Show all required drag struts on framing plans. In Seismic Zone 4, aspect ratios are limited to :1 for wood shear panels. Table 23-1I-G. At first floor patio shear walls. Provide a complete shear wall schedule on plans. (UBC Table 23-I1-I-I). Please show the following: Specify nail size and spacing for each shear wall type. For example Sp-1 and Sp-2: The required nailing, A35 to transfer the shear for each shear wall type. Carlsbad 01-3154 10/12/01 . CITY SPECIAL REQUIREMENTS: 41. Nails for shear transfer connection (using A35's, etc.) may not be driven parallel to the flanges of TJI's (i.e., along the sides), per city policy, unless specific written approval from Trus-Joist Macmillan is first obtained. Details or notes on the plans should make this clear. Nails may be driven perpendicular to TJl flanges. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes 13 No L3 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Kai Tumalieh at Esgit Corporation. Thank you. Carlsbad 01-3154 10/12/01 VALUATION-AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 01-3154 PREPARED BY: Kal Tumalieh DATE: 10/12/01 BUILDING ADDRESS: 2653 Sausalito Ave. BUILDING OCCUPANCY: R-3/U-1 TYPE OF CONSTRUCTION: VN BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Room Add. 347 City Val. 35,741 Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code 1cb 1By Ordinance $276.35 I Bldg; Permit Fee by Ordinance v I Plan Check Fee by Ordinance v I $179.63 I Type of Review: I Complete Review 0 Structural Only 0 Other 0 Repetitive Fee I vj Repeats Hourly I Hour * Esgil Plan Review Fee I $154.761 Comments: Sheet I of I macvalue.doc EST. VALUE: 3 -L// 0,J C~Aqe of Carlsbad BUILDING PLANCHECK CHECKLIST.. DATE: /i9/O/ . PLANCHECKNO.: CB IIII flIM( Afl - .SnC,,Lië A,IQ PROJECT DESCRIPTION: ASSESSOR'S PARCEL NUMBER: ENGINEERING DEPARTMENT APPROVAL . The item you have submitted for review has been approved. The approval is. based .on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions Lin this report can- result in suspension of permit to build. DENIAL Please see the attached report of deficiencies marked with 0. Make necessary corrections to plans or specifications for, compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. By: . Date: 0 A Right-of-Way permit is required prior to construction of the following improvements: By: . . Date: By:. . Date: W.'FOR OFFICIAL USEO . / ,..LENGlNEERING AUTHORIZATION TO ISSUE BUILDING PERMIT z~id(M.,Date C1 Dedication Application Dedication Checklist Improvement Application El Improvement Checklist U Future Improvement Agreement Grading Permit Application O Grading Submittal Checklist U Right-of-Way Permit Application ENGINEERING DEPT. CONTACT PERSON Name: TANIYA WADE City of Carlsbad Address: 1635 Faraday Avenue, Carlsbad, -CA 92008 Phone: (760) 602-2773 CFD INFORMATION Parcel Map No: Lots: Recordation: Right-of-Way Permit Submittal Checklist Carlsbad Tract: and Information Sheet 0 Sewer Fee Information Sheet , ' A-4 go knu romi . Carlsbad, CA 92008-7314 • (760) 602-2720 • FAX (760p-8562 ® JJ.doc I BUILDING PLANCHECK CHECKLIST L 2JD- 3RD 0 SITE PLAN 1. Provide a fully dimensioned site plan drawn to scale. Show: Af'North Arrow ,,BJxi~fing & Proposed Structures ejsting Street Improvements 2ProoertV Lines / asements (1Right-of-Way Width & Adjacent Streets (-G--Driveway widths H, Existing or proposed sewer lateral )( Existing or proposed water service. Existing or proposed irrigation service 2. Show on site plan: /-K.--Drainage Patterns Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building." Existing & Proposed Slopes and Topography Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project; Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception. Sewer and water laterals should not be located within proposed driveways, per standards. 3. Include on title sheet: Site address Assessor's Parcel Number Legal Description For commercial/industrial buildings and tenant improvement• projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION H:WORDDOCSCHKISfl8uildtl planthodi CkI5t Form (GcneidaC Rev. 71141C0 BUILDING PLANCHECK CHECKLIST 1ST 2ND 3 rd DISCRETIONARY APPROVAL COMPLIANCE cth 0 4a. Project does not comply with the following Engineering Conditions of approval for V ( Project No.________________________________________________________ 0 0 0 4b. All conditions are in compliance. Date: DEDICATION REQUIREMENTS 0 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $15.000, pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 W x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form 'with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by: Date: IMPROVEMENT REQUIREMENTS iA 0 0 6a. All needed public improvements upon and adjacent to the building site must be 'LI ( constructed at time of building construction whenever the value of the construction exceeds $75.000, pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: Attached please find an application form and submittal checklist for the public improvement requirements. A• registered Civil Engineer must prepare the appropriate improvement, plans and submit them .together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the H:WORDDOCSCHK.Sfl8uIIdifl9 PandIedc Cicist Form (RIDDLE - HARVEY 7.12.)doc 3 Rev. 12128196 BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by: Date: El El El 6b. Construôtion of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $310 so we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. Future public improvements required as follows: El El El 6c. Enclosed please find your Future Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. Future Improvement Agreement completed by: Date: El 0 El 6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adiacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. El El. El 7a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). El El El 7b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by: Date: El 0 El 7c. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) H:WORDOcS\cHKLSTBulldng Plancheck Cklat Penn (Generic 7.14.00).dac 4 Rev. 7114100 BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD 0 7d .No Grading Permit required. fl 7e. If grading is not required, Write "No Grading" on plot plan. MISCELLANEOUS PERMITS 0 0 8. A RIGHT-OF-WAY PERMIT is required to .do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. Right-of-Way permit required for: iA1tK1 0 0 9. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List. You may telephone (760) 438-2722, extension 7153, for assistance. Industrial Waste permit accepted by: Date: 0 D 10. NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit. The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas. Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first. 11. U Required fees are attached 9Afo fees required WATER METER REVIEW 4lC.4 J J 12a. Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized. Oversized meters are inaccurate during low-flow conditions. If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used. All single family dwelling units received "standard" 1" service with 5/8" service. HWORDDOCSCHXSTBuildh Pand,edc Ckt Form (GenellC).doc 5 Rev. 71*4100 BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm). A typical fixture count and water demand worksheet is attached. Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit. Maximum service and meter size is a 2" service with a 2" meter. If a developer is proposing a meter greater than 2, suggest the installation of multiple 2" services as needed to provide the anticipated demand. (manifolds are considered on case by case basis to limit multiple trenching into the street). 12b. Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval. The developer must provide these calculations. Please follow these guidelines: If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets. If so, at the water meter station, the demand in gpm may be listed there. Irrigation services are listed with a circled "I", and potable water is typically a circled "W". The irrigation service should look like: _i .-.. STA 1+00 Install 2" service and 1.5: meter (estimated 100 gpm) If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (wl a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach). Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use. Once you have received a good example of irrigation calculations, keep a set for your reference. In general the calculations will include: Hydraulic grade line Elevation at point of connection (POC) Pressure at POC in pounds per square inch (PSI) Worse case zone (largest, farthest away from valve Total Sprinkler heads listed (with gpm use per head) Include a 10% residual pressure at point of connection 3. In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SF0 with no HOA). As long as the project is located within the City recycled water HWORDDOCSCHXI.STWuIIdIi Planched, cidet Form (Genedc)doc 6 Rev. 7114100 BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD service boundary, the City intends on switching these irrigation services/meters to a new recycled water line in the future. D 12c. Irrigation. Use (where recycled water is available) Recycled water meters are sized the same as the irrigation. meter above. If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development. For subdivisions, this should have been identified, and implemented on the improvement plans. Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees. However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge. If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a .refund However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this. D 13. Additional Comments: HWORDDOCSCHktZflBthIfl9 planthedc 0,1st Fo,m (GenetIc) doc 7 Rev. 7114100 PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB Address Planner 6m&— T;&Ee Phone (760) 6024621 Type of Project & Use: Net Project Density: DU/AC Zoning: General Plan: Facilities Management Zone: CFD (in/out) #Date of participation: Remaining net dev acres:______ Circle One (For non-residential development: Type of land used created by this permit: ) - Legend: Item Complete Item Incomplete - Needs your action Environmental Review Required: YES • NO TYPE • DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: E Discretionary Action Required: YES ____ NO TYPE APPROVALJRESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES____ NO____ CA Coastal Commission Authority? YES____ NO____ • If California Coastal Commission Authority: Contact them at -.7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): Coastal Permit Determination Form already completed? If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: YES NO, Follow-Up Actions: 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). V , 2) Complete Coastal Permit Determination Log as needed. 1• H:ADMiN\COUNTER\BldgPInchkRevChklst IncIusionary Housing Fee required: YES NO (Effective date of lnclusionary Housing Ordinance- May 21, 1993.) Data Entry Completed? YES ____ NO (NP/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing YIN, Enter Fee. UPDATE!) Site Plan: Provide a fully dimensional site plan drawn to scale. Show: North arrow, property. lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). Provide legal description of property and assessor's parcel number. I. A Zoning: 1. Setbacks: 1" Front: Required zi~b Shown ' Interior Side: Required 6' Shown J V Street Side: Required Shown _______________ Rear: Required / - Shown 1' Top of slope: Required --- Shown _____________ I1' L1 2. Accessory structure setbacks: - Front: Required Shown Interior Side: Required Shown Street Side: Required • Shown Rear: Required Shown Structure separation: Required Shown Lot Coverage: Required h Shown tcMAc Height: Required Shown 30 Parking: Spaces Required Show (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Additional Comments_____________________________________________________ OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER if- DATE(#f'"O/ H:\ADMIN\COUNTER\BldgPlnchkRevChklst