Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1923 CALLE BARCELONA; 149; CBC2019-0518; Permit
C(Pol Cityof / Building Permit Finaled Carlsbad Commercial Permit Print Date: 09/04/2020 Permit No: CBC2019-0518 Job Address: 1923 CALIF BARCELONA, # 149, CARLSBAD, CA 92009-8458 Status: Closed - Finaled Permit Type: BLDG-Commercial Work Class: Tenant Improvement Parcel #: 2550120400. Track #: Applied: 11/01/2019 Valuation: $480,913.40 Lot #: 1 Issued: 06/05/2020 Occupancy Group: Project #: Finaled Close Out: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: CRenf Plan Check #: Final Inspection: 09/04/2020 Project Title: Description: JIMBOS: REPLACE EXISTING REFRIDGERATION SYSTEM AND STORE EQUIPMENT (10,340 SF TI) Property Owner: Contractor: T-C FORUM AT CARLSBAD LIC KIRKLEY CORPORATION INC 4675 MACARTHUR CT, # 110 P0 BOX 7268 NEWPORT BEACH, CA 92660 REDLANDS, CA 92374-0000 (909) 792-4625 FEE. . AMOUNT BUILDING PERMIT FEE ($2000+) . . $1,219.44 BUILDING PLAN CHECK FEE (BLDG) . $2,144.10 ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL $89.00 FIRE Special Equipment (Ovens, Dust, Battery) . . $417.00 GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION $175.00 MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL . $55.00 PLUMBING BLDG COMMERCIAL NEW/ADDITION/REMODEL . $86.00 5B1473 GREEN BUILDING STATE STANDARDS FEE $20.00 STRONG MOTION-COMMERCIAL . $134.66 Total Fees: $4,340.20 Total Payments To Date: $4,340.20 Balance Due: $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date thispermit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review,-set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest thespecified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-2700 1 760-602-8560 f I www.carlsbadca.gov ( J(\/ (;1 C"Asbad COMMERCIAL BUILDING PERMIT APPLICATION B-2 Ict. V.sluc •____it - lit flProsal 1)t' / !p00__ Job Address 1923 Calle Barcelona Suite: 149 APN: 255-012-04-00 Tenant Name: Jimbo's Naturally CT/Project 0: Lot Q:__________ Occupancy: Grocery store (M) Construction Type: VN Fire SprinkIors:/ no Air Conditioning: no BKI€f uisinw Io.: th WOK:. Replace Existing Refrigeration System and Store Equipment Addition/New: New SF and Use, New SF and Use, Deck SF, Patio Cover SF (not including flatwork) Ten.int Improvement: 18,088 SF, Existing Use Grocery Store Proposed Use Grocery Store SF, Existing Use Proposed Use Poi,I/Spa: ____________ SF Additional Gas or Electrical Features? Solar: _______ KW, _____ Modules, _______ Mounted, Tilt: Yes/ No, RMA: Yes / No, Panel Upgrade: Yes / No 0 Plumbing/Mechanical/Electrical only: Existing Mech. No Change /Plumbing & Electrical Revised 0 Other: Remove APPLICANT (PRIMARY) PROPERTY OWNER Name: Anthony Mansour Name: T-C FORUM AT CARLSBAD, LLC Address: Address:730 Third Ave, MS 730/12/02 City: State: zip: City: New York State: NY zip: 10017 Phone: Phone: Email: Email: DESIGN PROFESSIONAL Name: Anthony Mansour Address: 6498 Weathers Place Suite 100 City: San Diego State:CA Zip: 92121 Phone:(858) 558-1509 Email: tmansour@mansoUrarchitecture.com Architect State License: C20392 CONTRACTOR BUSINESS Name: Address: \. ) ck City:CiLJS State: _ Zip: TLs Phone: ct oR -- .. - L.. s Email: State License: t O Bus. License:1LSW?9 (Sec. 7033.5 Business and Professions Code: Any City or County which requires a permit to construct, alto,, improve, demolish or repair any structure, prior to its Issuance, also requires the applicant for such permit to file a signed statement that he/she i s l i c e n s e d p u r s u a n t t o t h e p r o v i s i o n s o f t h e C o n t r a c t o r ' s L i c e n s e L a w (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) o r t h a t h e / s h e i s e x e m p t t h e r e f r o m , a n d t h e b a s s f o r t h e a l l e g e d exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applica n t t o a C i v i l p e n a l t y o f n o t m o r e t h a n l i v e h u n d r e d d o l l a r s ( 5 5 0 0 ) ) . 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: UtnIdi@ cat Isbadcs.gy 8-2 Page 1 of 2 Rev. 06118 0"110N A I' OVI-I.AfIA11014. I hearby affirm under penalty of perjury one of the following declarations: 0 have and will maintain a certificate of consent to self-insure for workers' compensation p r o v i d e d b y S e c t i o n 3 7 0 0 o f t h e L a b o r c o d e , f o r t h e p e r f o r m a n c e o f t h e work which this permit is Issued. I have and will maintain worker's compensation, as required by Section 3700 al t h e L a b o r C o d e , I o r . t h e p e r f o r m a n c e o f t h e w o r k f o r w h i c h t h i s p e r m i t i s i s s u e d . My, workers comp n sion nsurance carrier antI policy number are: Insurance company Name: 14 t, 5. .• . -6't pc (s Policy No. .A!L . ''7 S, ' Expiration Date: CI Certificate of Exemption: I certify that in the performance of the work for which this pe r m i t i s i s s u e d , I s h a l l n o t e m p l o y a n y p e r s o n i n a n y m a n n e r s o a s t o b e c o m e subject to the workers' compensation Laws of California. WARNING: Failure to secure workers co m p e n s a t i o n c o v e r a g e I s u n l a w f u l , a n d s h a l l s u b j e c t a n e m p l o y e r t o criminal penalties and civil fines up to $100,000.00, In addition the to the cost of compensation, damages as provided for In Section 3700 of the Labor Code, Interest and attorney's fees. CONTRACTOR SIGNATURE: AGENT DATE: I OI'TIO1 B ): R.IJlt.PkDFcLjjçJN: I hereby affirm that I am exempt from contractor's License Law for the followin g r e a s o n : 0 I, as owner of the property or my employees with wages as their sole compen s a t i o n , w i l l d o t h e w o r k a n d t h e s t r u c t u r e i s n o t i n t e n d e d o r o f f e r e d f o r s a l e ( S e c . 7046, Business and Professions Code: The Contractor's License Law does not apply to an o w n e r o f p r o p e r t y w h o b u i l d s o r i m p r o v e s t h e r e o n , a n d w h o d o e s s u c h w o r k himself or through his own employees, provided that such Improvements are n o t i n t e n d e d o r o f f e r e d f o r s a l e . I f , h o w e v e r , t h e b u i l d i n g o r i m p r o v e m e n t i s s o l d w i t h i n one year of completion, the owner-builder will have the burden of proving that h e d i d n o t b u i l d o r I m p r o v e f o r t h e p u r p o s e o f s a l e ) . CII, as owner of the property, am exclusively contracting with licensed contractors to c o n s t r u c t t h e p r o j e c t ( S e c . 1 0 4 4 , B u s i n e s s a n d P r o f e s s i o n s C o d e : T h e Contractor's License Law does not apply to an owner of property who builds or improves t h e r e o n , a n d c o n t r a c t s f o r s u c h p r o j e c t s w i t h c o n t r a c t o r ( s ) l i c e n s e d pursuant to the Contractor's License Law). CI lam exempt under Section Business and Professions Code for this reason: I. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 Yes CI No I (have I have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work ( i n c l u d e n a m e I address/ phone/ contractors' license number): S. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include n a m e /address / phone I type of work): OWNER SIGNATURE: DAGENT DATE:____________ CONSTRUCTION LENDING AGENCY. I hereby affirm that there is a construction lending agency for the performance of the wo r k t h i s p e r m i t I s I s s u e d (Sec. 3097 (I) Civil Code). Lender's Name: Lender's Address: ONLY COMPLETE I HE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, a c u t e l y h a z a r d o u s m a t e r i a l s r e g i s t r a t i o n f o r m o r r i s k m a n a g e m e n t a n d p r e v e n t i o n program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazard o u s S u b s t a n c e A c c o u n t A c t ? 0 Y e s ) I N o Is the applicant or future building occupant required to obtain a permit from the air p o l l u t i o n c o n t r o l d i s t r i c t o r a i r q u a l i t y m a n a g e m e n t d i s t r i c t ? D Y e s No Is the facility to be constructed within 1,000 feet of the outer boundary of a sch o o l s i t e ? - 0 Yes 15 No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY N O T B E I S S U E D U N L E S S T H E A P P L I C A N T H A S M E T O R I S M E E T I N G T H E REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CO N T f t O I . D I S T R I C T . APPLICANT CERTiFICATION: I certify that I have read the application and state that the above Information is corre c t a n d t h a t t h e i n f o r m a t i o n o n t h e p l a n s i s a c c u r a t e . I a g r e e t o c o m p l y w i t h a l l City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned prope r t y f o r i n s p e c t i o n p u r p o s e s . I A L S O A G R E E T O S A V E , I N D E M N I F Y A N D K E E P HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSE S W H I C H M A Y I N A N Y W A Y A C C R U E A G A I N S T S A I D C I T Y I N C O N S E Q U E N C E O F THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations ov e r 5 ' O ' d e e p a n d d e m o l i t i o n o r c o n s t r u c t i o n o f s t r u c t u r e s o v e r 3 s t o r i e s i n h e i g h t . EXPIRATION: Every permit issued by the Building Official under the provisions of this Code sha l l e x p i r e b y l i m i t a t i o n a s id become null and voId if the building or work authorized by such permit Is not commenced within 180 days from the date of such permit or i f t h e b u i l d i n g c r w o f t a y t h c r i f ' d b y s u c h p e r m i t i s s u s p e n d e d o r a b a n d o n e d a t a n y t i m e after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building C o d e ) . APPLICANT SIGNATURE: / DATE:________________ C. 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: B-2 Page 2 of 2 Rev. 06/18 Permit Type: BLDG-Commercial Application Date: 11/01/2019 Owner: T-C FORUM AT CARLSBAD LLC Work Class: Tenant Improvement Issue Date: 06/05/2020 Subdivision: CARLSBAD TCT#92-08 GREEN VALLEY Status: Closed - Finaled Expiration Date: 02/08/2021 Address: 1923 CALLE BARCELONA, # 149 IVR Number: 22856 CARLSBAD, CA 92009-8458 Scheduled Actual Inspection Type Inspection No. Inspection . Primary Inspector Reinspection Inspection Date Start Date Status Checklist Item COMMENTS Passed FIRE- Building Final Labeling required near local No strobe/sounder. See plans for verbiage. Back up batteries required in panel. All functional test passed. Photos of corrections acceptable. No re-inspection required. 09/04/2020 09104/2020 BLDG-Final Inspection 137590-2020 Passed Chris Renfro Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes Friday, September 4, 2020 . Page 2 of 2 Cray of Building Permit Inspection History Finaled Carlsbad Permit Type: BLDG-Commercial Application Date: 11/01/2019 Owner: T-C FORUM AT CARLSBAD LLC Work Class: Tenant Improvement Issue Date: 06/05/2020 Subdivision: CARLSBAD TCT#92-08 GREEN VALLEY Status: Closed - Finaled Expiration Date: 02/08/2021 Address: 1923 CALLE BARCELONA, # 149 IVR Number: 22856 CARLSBAD, CA 92009-8458 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 06123/2020 06/2312020 BLDG-14 130864-2020 Passed Chris Renfro Complete Frame!SteellBoltiñglWe iding (Decks) Checklist Item COMMENTS . Passed BLDG-Building Deficiency Yes 07/20/2020 07/20/2020 BLDG-84 Rough 133304-2020 Cancelled Chris Renfro Reinspection Incomplete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency . No BLDG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rouh Electrical No BLDG-44 No Rough-Ducts-Dampers 08/12/2020 08/11/2020 BLDG-84 Rough 135300-2020 Cancelled Chris Renfro Reinspection Incomplete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-14 . No. Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical . No BLDG-44 . No Rough-Ducts-Dampers Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 08/14/2020 08/14/2020 BLDG-Fire Final 135515-2020 Partial Pass Felix Salcedo Reinspection Incomplete Friday, September 4, 2020 . Page 1 of 2 DATE: 3/5/2020 EsGilV/0 A SAFEbulif Company U 'ICANT eJ URIS. JURISDICTION: CC.rls) PLAN CHECK #.: CBC2019-0518 SET: II PROJECT ADDRESS: 1923 Calle Barcelona #149 PROJECT NAME: Jimbo's T. I. The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. Fj The applicant's copy of the check list has been sent to: EsGil staff did not advise the applicant that the plan check has been completed. iIi EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by ) Email: Mail Telephone Fax In Person E1 REMARKS: By: David Yao Enclosures: EsGil 2/21/20 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EtGO A SAFEbuiLt'Company DATE: 11/12/2019 0 APPLICANT 0 JURIS. JURISDICTION: Carlsbad PLAN CHECK#.: CBC2019-0518 SET:I PROJECT ADDRESS: 1923 Calle Barcelona #149 PROJECT NAME: Jimbo's Tenant Improvement The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. El The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. El The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. EJ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Anthony Mansour EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Anthony Mansour Telephone #: 858-558-1509 Date contacted: (by: ) Email: tmansour@mansourarchitecture.com Mail Telephone Fax In Person LI REMARKS: By: JasOn Pasiut Enclosures: EsGil 11/4/2019 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad CBC20 19-0518 11/12/2019 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK#.: CBC2019-0518 OCCUPANCY: M TYPE OF CONSTRUCTION: V-N ALLOWABLE FLOOR AREA: complies SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 11/1/2019 DATE INITIAL PLAN REVIEW COMPLETED: 11/12/2019 FOREWORD (PLEASE READ): JURISDICTION: Carlsbad USE: Merchantile Sales ACTUAL AREA: 18,088sf STORIES: 1 HEIGHT: unchanged OCCUPANT LOAD: 224 DATE PLANS RECEIVED BY ESGIL CORPORATION: 11/4/2019 PLAN REVIEWER: Jason Pasiut This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2016 CBC, which adopts the 2015 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CBC20 19-0518 11/12/2019 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. PLANS Each sheet of the plans must be signed by the person responsible for their preparation, even if there are no structural changes. California State Law. i) R sheets require signature of responsible designer. Please provide a plumbing drainage fixture count to verify that the existing grease interceptor can accommodate the new layout. . ACCESSIBILITY FOR REMODELS, ADDITIONS, AND REPAIRS The following disabled access items are taken from the 2016 edition of California Building Code. Per Section 1.9.1.2, all privately funded public accommodations and commercial facilities shall be accessible to persons with disabilities. Where existing elements or spaces are altered, each altered element or space shall comply with applicable requirements of Division 2, including CBC section 11 B-202.4. CBC section 11 B-202.4 states that when alterations or additions are made to existing buildings, an accessible path of travel to the specific area of alteration shall be provided. See exceptions to 11 B-202.4. Detail on the plans the following elements of the existing path of travel that are required to comply with the 2016 accessibility standards: Existing primary path of travel to the building or facility entrance, including: a) The accessible parking dimensions, slope, and cross-slope in compliance with CBC 11 B-502. Carlsbad CBC2019-05 18 11/12/2019 The access aisle dimensions, slope, and cross slope in compliance with 11 B-502.3. The location of detectable warnings at hazardous vehicle areas. 116- 705.1.2.5. The curb ramp (if any) 48" minimum width, 48" x 48" turning space at the bottom, landing length of 48" at the top, slope and cross-slope in compliance with CBC 11 B-406. The ramp (if any) slope, cross-slope, 48" minimum width, 60" x 60" landing at the top, 72" long landing at the bottom, compliant changes in direction (60" x 72") in compliance with CBC 11 B-405. The stair (if any) width, riser and tread dimensions, contrasting stipes, handrail height, gripping surfaces and top/bottom extensions in compliance with CBC 11 B-504 and 505. Show that the walking surface from the access aisle to the building entrance complies with slope, cross slope, changes in level and clear width provisions of 11 B-403. Show the accessible entrance door threshold, door hardware, door width, and maneuvering clearances on either side of the door in compliance with CBC 11 B-206.4. 4. Existing toilet facilities that serve the remodeled area shall be shown to comply with the accessibility features of CBC, 11 B, Division 6. Provide generic restroom details showing compliance. 5. Existing drinking fountains (if any) shall be shown to comply with the accessibility features of 11 B-602 and 11 B-211.2. 6. Existing accessible parking reflectorized identification including the "van accessible", "250 fine", and "unauthorized vehicle parking" signs per 11 B-502.6, 11 B-502.6.2, 11 B-502.8.2. Existing accessible parking surface identification. 11 B-502.6.4.1. Existing access isle "NO PARKING" identification per 11 B-502.3.3 C) Provide the address and phone number for the location to reclaim towed vehicles. 11 B-502.8.2. 7. Show that compliant restrooms are marked with signs per 11 B-216.8 with the international symbol of accessibility and geometric symbols per 11 B-703.7.2.6. a) ABI 732 Section 1, Article 5: 118600: Carlsbad CBC2019-05 18 11/12/2019 All single-user toilet facilities in any business establishment, place of public accommodation, or state or local government agency shall be identified as all-gender toilet facilities by signage that complies with Title 24 of the California Code of Regulations and designated for use by no more than one occupant at a time or for family or assisted use. b) The location of and directions to compliant restrooms shall be posted in or near the building entrance and shall include the International symbol of accessibility. 11 B-216.8. 8. Show the permanent sign identifying the restroom on the latch side of the doorway, in compliance with 11 B-703.1,2,3, and 5. (raised characters with braille installed 48" from the baseline of the lowest braille and 60" from the baseline of the highest raised characters) END OF REVIEW To speed up the review process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: U Yes U No The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Jason Pasiut at Esgil. Thank you. Carlsbad CBC2019-05 18 11/12/2019 Carlsbad CBC20 19-0518 11/12/2019 [DO NOT PAY— THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK#.: CBC2019-0518 PREPARED BY: Jason Pasiut DATE: 11/12/2019 BUILDING ADDRESS: 1923 Calie Barcelona #149 BUILDING OCCUPANCY: M BUILDING PORTION AREA (Sq. FL) Valuation ML4her Reg. Mod. VALUE ($) TI 10340 46.51 480,913 Air Conditioring Fire Sprinklers TOTAL VALUE 480,913 Jurisdiction Code Icb Ordinance 1997 UBC Building Permit Fee I IV I: 1997 UBC Plan Check Fee I hi Sl Type aiReview: W Complete Review rother r Repetitwe Fee I H Repeats r Hourly EWE Fee r Structural Only 1@* I $1,286.1O1 Comments: Sheet 1 of 1 OGSSI Structural Engineers Calculations for 19163A Jimob's Carlsbad 1923 Calle Barcelona, # 149 Carlsbad, CA 92008 Mansour Architecture 6498 Weathers Place, Suite 100 San Diego, CA 92121 Phone: 858-558-1509 Fax: 858-558-9221 D, ~10 ZAdIA), i:rI;1I OGSSI Structural Engineers SHEET, PROJECT ________________________________________ GSSI NO. ENGR O, DATE_I'2oI &1.416 C4i- kL,84C' (f244 L "T CA-01~0 G%..4 1' II II II— I I I ?,40o ro4f (iJi) eA, bLpc L4. lY Wt 3d ate i&'z4 ii II bL 1/Z4O 19 rr L4 t¼bç. B?cb e l •, 1q.,,g'j,6' 40' I*__- t 04.01F r D P3 P4e.: 2c0"f'z vr('3o): iso' f'c , i ç (#O)(1 c IhA.: L'(.*('v/i.): ;IoD Mg )4'?' Ov mi Seismic Design Maps https://seismicmaps.org/ OSHPD Jimbos Carlsbad 1923 CaVe Barcelona, Carlsbad, CA 92009, USA Latitude, Longitude: 33.0718691, -117.26524540000003 Buca di Beppo Italian fJ;mbols Naturally' Casa De Bandini 9 9 Apple Carlsbad Q Bed Bath &eyond Google \ Map data ©2019 Date 8/l/2019,2:13:58 PM Design Code Reference Document ASCE7-10 Risk Category ii Site Class D . Stiff Soil Type SS S1 SMS SM1 SDS SDI Value 1.088 0.42 1.158 0.663 0.772 0.442 Description MCER ground motion. (for 0.2 second period) MCER ground motion. (for 1.0s period) Site-modified spectral acceleration value Site-modified spectral acceleration value Numeric seismic design value at 0.2 second SA Numeric seismic design value at 1.0 second SA Type Value Description SOC D Seismic design category Fa 1.085 Site amplification factor at 0.2 second Fv 1.58 Site amplification factor at 1.0 second PGA 0.432 rvtE3 peak ground acceleration FPGA 1.066 Site amplification factor at PGA PGAM 0.461 Site modified peak ground acceleration TL 8 Long-period transition period in seconds SsRT 1.088 Probabilistic risk-targeted ground motion. (0.2 second) SsUH 1.15 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration SsD 1.512 Factored deterministic acceleration value. (0.2 second) SIRT 0.42 Probabilistic risk-targeted ground motion. (1.0 second) SIUH 0.419 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration. SID 0.609 Factored deterministic acceleration value. (1.0 second) PGM 0.578 Factored deterministic acceleration value. (Peak Ground Acceleration) 1 of 3 8/l/2019,2:14 PM Sheet 55 I Project: Jimbos GSSI No. 19163A. Structural Engineers Engr: OOG Date 8/2/2019. Anchorage of Mechanical Equipment on the roof Desian Parameters SCIS = 0.77 spectral acceleration, short period Strength Design: .90 +11.01E ip = 1.00 importance factor Allow. Stress Design: .6D + 1.OE/1 .4 ap = 2.5 component ampflication factor SD or ASD? = Allow. Stress Design R = 6.0 Component response mod. factor z = 25 ft. (ht. in structure of point of attachment), z=0 © grade h = 25 ft. (avg. roof ht.) z/h= 1.0 F = .4*ap*Sos.Wp*(l +2*z1h)/(Rp/lp), (13.3-1) F(max)= 1.6*SDS *1 p *Wp. (13.3-2) F(min) = 0.3*SDS *1 p *J p. (13.3-3) F= .14*Sds*Wp, (12.4.2.3) F = 0.28 W, OTM = Fp*unit height/2 F(max) = 0.88 Wp RM=(.6FV)*Wt*Uflit width/2 F(min) = 0.17 W, F= 0.11 W, Emm Screw Table Vail, lbs Tail, lbs "Tall = thread length x W 1/4" dia. x 3 1/2" SDS screws 250 345 5/16" dia.x 4" lag screws 190 532 3 1/2" embedment (T-E= 2 5/16", 266 p11) 3/8" dia. x 5" lag screws 200 839 4 1/2" embedment (T-E= 2 3/4". 305 ph) 1/2" dia. x 5" lag screws 290 992 4 1/2" embedment (T-E= 2 5/8", 378. p11) Unit No of anchors per side Screw Type and Length Max. spacing, inches Fp, per anchor, lbs T, per anchor, Resultant, lbs. lbs Za', lbs. Za'"1.60, lbs. Remarks %, cap. Condensor 3 3/8" dia. x 5" lag screws 57 106 0 106 200 320 Okay 33% Rooftop overturning - wood OGSSI Structural Engineers 19163A Jimob's Carishad AP)p en dlitx 0 fts GSSI Structural Engineers I Project: Jimbos Engr: OOG Sheet: Project No. A Date: 812/2019 6 3/4" Glue Laminated Beams Width = 6.75 inches Fb = 2400 psi E = 1.8E+06 psi Lumber wt. = 35 psf Fv= 265 psi Cd, roof = .1.25 Span= 32 ft Cm I I Floor I Roof I Depth Area Sx Cv Sx*Cf I W, bean Mx V Mx V Depth inches in'2 in"3 inA3 mM pif ft-k kips ft-k kips inches 12.0 81.0 162 0.93 151 972 20 30 14.3 38 17.9 12.0 13.5 91.1 205 0.92 189 1384 22 38 16.1 47 20.1 13.5 15.0 101.3 253 0.91 231 1898 25 46 17.9 58 22.4 15.0 16.5 111.4 306 1 0.90 277 2527 1 27 55 19.7 69 24.6 16.5 18.0 121.5 365 0.90 326 3281 30 65 21.5 82 26.8 18.0 19.5 131.6 428 0.89 380 4171 32 76 23.3 95 29.1 19.5 21.0 141.8 496 0.88 438 5209 34 88 1 25.0 109 1 31.3 21.0 22.5 151.9 570 1 0.88 499 6407 37 100 26.8 125 33.5 22.5 24.0 162.0 648 0.87 564 7776 39 113 28.6 141 35.8 24.0 25.5 172.1 732 0.86 633 9327 42 127 30.4 158 38.0 25.5 27.0 182.3 820 0.86 705 11072 44 141 32.2 176 40.2 27.0 28.5 192.4 914 0.86 782 13021 47 156 34.0 195 42.5 28.5 30.0 202.5 1013 0.85 862 15188 49 172 35.8 215 44.7 30.0 31.5 212.6 1116 0.85 945 17581 52 189 37.6 236 47.0 31.5 33.0 222.8 1225 0.84 1033 20215 54 207 39.4 258 49.2 33.0 34.5 232.9 1339 0.84 1124 23098 57 225 41.1 281 51.4 34.5 36.0 243.0 1458 0.84 1218 26244 59 244 42.9 305 53.7 36.0 37.5 253.1 1582 0.83 1317 29663 62 263 44.7 329 55.9 37.5 39.0 263.3 1711 0.83 1419 33367 64 284 46.5 355 58.1 39.0 40.5 273.4 1845 0.83 1524 37367 66 305 48.3 381 60.4 40.5 42.0 283.5 1985 0.82 1633 41675 69 327 50.1 408 62.6 42.0 43.5 293.6 2129 0.82 1746 46301 71 349 51.9 436 64.8 43.5 45.0 1 303.8 2278 0.82 1862 51258 74 372 53.7 465 67.1 45.0 46.5 1 313.9 2433 0.81 1981 56556 76 396 55.5 495 69.3 46.5 48.0 324.0 2592 0.81 2105 62208 79 421 57.2 526 71.6 48.0 49.5 334.1 2757 0.81 2231 68224 81 446 59.0 558 73.8 49.5 51.0 344.3 2926 0.81 2362 74616 84 472 60.8 590 76.0 51.0 52.5 354.4 3101 0.80 2495 81396 86 499 62.6 624 78.3 52.5 54.0 364.5 3281 0.80 2632 1 88574 89 526 64.4 658 80.5 54.0 6 GLB spaning OR 6 GLB spaning OR BF 8 9.0 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 ELECTRICAL CONTRACTOR TØ WIRE. & CONNECT PER LOCAL CcpDES. SEE REFRIGERATION SCHEDULE & WIRING SCHEMATICS FOR MORE INFORMATION TYPICAL (4) PLA4ES ANCHORING OF ROOF TOP UNITS BY GRIND N—' RtFRIGERAIION CONTRACTOR. VERIFY ANCHOR TYPE & LOCATION WITH ARCHITECT FOR CLARITY UIRWU ARE W MZR CONDENSING UNIT DETAILS 4— MZR UNIT WITH LAHB-13412—K I ON ROOF VERIFY WITH LANDLORD GENERAL CONTRACTOR IQJ PLATFORM FOR GROUND LEVEL MI LOCATION PRIOR TO 1DENSING UNITS A' ECT, THIS LOCATION. 125" X 57" X 51"H WEIGHT: 2293 LBS ANY RELATED WORK I I I NEW NOR UNIT WITH INB-13412-II OUTDOOR CIDIOCNSING UNITS A ON ROOF NW? WITH INLOLORO AND ARCHITECT. 11415 LOCATION. SIZE- 125 U Dr N DFH WEIGHT: 2293 LBS RIASEGEM TON GROUND LENDI. MOUNTED EOUIPNEIIT. 9(519? OPel LOCUTION PRIOR TO PENFONIRNO NIT ROATES RN .I :,I NEW NOR UNIT WITH LAMB-133110-11001000W CONITETOOTIO UNITS A - ' ' ON ROOT NINA? WITH IMDEOITD AND WIDITTECI. tHIS LOCATOR. SIZE- ID5'SD7'XSI14 'NEW NOR UNIT WITH L4143-13412-K OUTDOOR CONODINING UNITS 14 WEIGHT. 2293 LOS ON ROOF HENRY WITH LNITD.00O AND MDGTECT. THIS LOCATION. OENENM. CONTRACTOR TO ONDOTNE .9 LINE INTEl 125' 2 sr IT 5194 IOA2F0OM TON GROUND LEND. UDUNTOD (OUIPIIDIT. NOOFY COREY I WEIGHT I 2203 LOS I WCATIOH PNIOH TO PENFONIRNO NIT RElATED WORK OZN(5H. CONTRACTOR &V TH A LI IOANM FOR GROUND tENET. II2UNTCO EOIIIPIADOT. HENRY DOCT LOCATION PRIOR TO PCIjAONIIO[O NIT RELATED WORK II UAI ELECTWCAI. CONTRACTOR TO WINE & ? + 11 ANEE COOINIVIUTE WITH IIZIO1C DO CONNECT PEW LOCH. 000(5. DEC A I &IDVTECT HID VZFNATON CONTN*I OUTUICCOATION SCHEDULE '& WINING PWONJIINO WIlY RElATES NOON SCHETIATIES FOR NONE 11,21MNTION H. IGRN, S ...........................F•• NEW MOW UNIT WITH IMB-13412-G OUTDOOR ONDDOONG UNITS A ON ROOF HEWITT WITH LNNILORO AND ARDRIECT. THIS LOCATOR. I I ISZC 125' 0 57' 0 DTH I I WEGHTI 2293 LBS r GENERA. COTITRAETON TO A IOA2CO2N FOR GROUND LEND. UDJRIW LOUPUENT. HEWITT DOG I I I I TO PCTITONIIINO NIT RElATED RONO H - -4 +11+ I-- I I I I I Ii I I I i. NEW ROUDUE DEFROST PANEL (03'R 0 2714 U N.22'O) I TO RE LOCATES ON MESOINIWE LEND.. IT SHOUlD BE ___ I I 11 I [ 0 1 I I LOCATED AS CLOSE TO ROW COTIDOISNO UNITS AS I FEASINLY POSSINLE. LOCUTION TO RE APPRONED BY I - I I ANDGTECT. .944301 WILD RCFRIOERATION CONTRACTOR I I 4111W TIITT, i WORE ART RElATED WORK IS 2. EILCTWICAI. CONTRACTOR TO MOUNT. WIRE E AND CONNECT ' I A 48 MXIAUM CIZIRNICE IS REQUIRED ON ALL DOES OF THE MOO CONOENSINO UNIT TO I I. . PEN WEAl. COOCO. I ASSURE AIR FLOW FOR OPERATION. COON I I I I I N CONDENSING UNIT PLAN R5 VV IAROLM TW ENTIRE PE RMIER AT 5TONT INS7 &L A 115 I/b X lb 6L8T1OM AT W-W TO MATCH 1 .BOTTOM ELEVATION 0111W MOMENT lE5. COOS 2 I HEADERS AT SPLICES PLIC 1,17"CMSTI2, W8O-lOd NAILS HORS TO MOMENT FRAME HI A 1615 STRAP. (80 NAILS AT Ek I 1 — EIØ•I9 f fr ,/ fi bi .0 iI OT t 23 Lu :FIIIIIIIIIIIIIIIII liii u-i b III I u-i Uwb I" r ? 0 'lit It R 11 Ix .0 0 .0.0.0.0 .0 .0g0U.00 Ix 0 .0 xx .0 .0 .0 .00 3 fl LL .4: lit lilt - U- LU b Lu lit aC IL b Ik I! z -I HI 0 p 0- iew U.' LU U- -t le LI lit z 9 ID O 222 114 1940, I: _ Oki - I _ ff kill I I -IL I— I I J - [ - I ------ El - I Eiis J 4 wan dAL .$ 0 XWE 1%.Q01 aIX3 EL — T ____________________ ____________________ ()4 166 - tan dl.L 0 XI.ZE 165 SWH 'Zjan II • xlcs 166 .61.6'Il 65(j Iv .91 0 XNTS 66 .cb El I N1IiI1I 1% rM4 NOQ4X O iON g EIIIL V .qVe XWEE 66. FLAIl- 51RkP PER Ft.M. BACKSIDE - OF LESSER TO FAGS Of BEAM I I II II II II I •I ........... I®. miSS ARWID ROOF DRAM TY SE ARCH'S DiES FOR SIZE NO LOCATION 6LIJE-LM BEAM FIR PLAN OilER INFO NOT S+4OY*4 FOR CLARTY. GL BEAM TO LEDGER / I4XI2ILEPGER I \ 2xSTUDSI TRUSSES SI6'O.G. IM-5/S" LAO $/4'l S PERJMETER, LINE UP AS REGD. I ENDED IN S1UP I 5Il 55 ARCH. PLAN I AP@SP.IG! PLYNOOP SHEATHING PER PLAN - I PLAN ON TRUSG PER PLAN I I OEM I 1 25-O' I / • SP .L TO TRUSS I FlOOD GRAIN PARALLEL I I PLY I .. •1 ... _ I 118-8 HEETSOAFORALL M& nmE Tim AND NOTES L ROOFDRAJNM NO 0— _Q 5wHM 964Ak. P.M. THE THE %S BRACE Mr ivi 1A1 rm Sim rnmr LINE zb CE br low TV? 12 TRW BLICS. Typ ,--LINES OF KAW;Mi \Ikp THIS /VT NMI _ . ARG4& W6S F . LOCATION . SEMCH .;51Ivs E SSSA N I i5 1 OR This I II LPORO 1!BE1W. -I- FOR SHEAR BIFO. This I - I UI SE q. FYP• I 50FIT. . ARCH lJj95 TW)SSES I F- ARW SKY 1.19. _ . ARSODSY . . __\.. -... I . . 61ES ON SKIPS ®ai(D . .—I4xI2 SI l.DSR 1600 p . 4x12 SI CCItT LPSR OR 2- PiES S . CR 2- AIDS's• -- SPLICE SPUCE ti- F UiE I N71 6-0 6'-O. - r 1.050 5 I I - 61.516 64.511 64.815 - I k TV6R 155 4 ____ . . I OP_ '°• . 4 iswr I4LiisSE-1 I WAL miss. ARCI60 1)5 SKY LTS \ Ill I . ______ ir iv ' 1 I _____________ 91WICATES MOMENIT RAME SEE AROUND THE ENTIRE PERIMETER AT S1ORRONT II8TMJ. I - - — A19I. A MIN 5 IFS X IS 64.9, BOTTOM AT I40 TO MATCH TIE I BOTTOM ELEVATION OF 115 $015141 FRAMES. C4IO4ECT THE I HEADERS AT SPLICES P11TH 06112. P1/ SO-lad NAILS$ HDRS TO P1011.1941 FRAME YV A 18115 STRAP. (SO NAILS AT EACH MEMBEK 2X STIFFENER MIN. W4-416d / I I . TRQSS HANGER PER TRUSS MWR. —" I wom am 1050' . A35 PER SHEAR PANEL _ SIX OR 2X ELKG. AS Z I 1W I , o - p SIN (0 ITO.C. HIM.) I II REQUIRED BY SHEAR LOS OP 11995 iYP B.S. o vu. (ON THE PLY SIDE I ___________ USE 2" LONG NAILS ) SX6 5 VS 02 OR ,4 JLSHEAR PANEL 2 I 811(6. SOFIT p - . . I STW. TM . .. IZO LO I - D - I . j -- I 42 RI LEDGER T50Nis PER SCHEDULE - J I OR 2- INS LINE I _ (450 USS 0 it) ALt. CONN._______ 7005 EAC44 SIDE CP811141 SPUCE, '-, I IPUI-S/b" LAG 11(41 AS-BUlL - tsoip is ep. iso • I - STUDS S TRUSSES 0 6. OL. I El-SEP IN STUD I IRESE TO CARRY 11€ EWPM81IT S PERIMETER, LINE UP AS REQ7. - 5T22SELOGKG , (STRAP 0 SPLICE EI.N. PER PLAN ON PLY PER PLAN 5116 SXS THIS um clao TFAW 13X PER SCHEDULE co 41(6 I ROOF DRAIN 1W, SE I IARC4l.'S P1465 FOR SIZE *10 LOCATION. I I I Ij ZE oI5WM - --r 51(4 ELCKG. 111TH L191 . l . TRaIlS I Z-CLIPS, (4-I0d TO PLY) - - I-IcrI • IIJ I EGCO.I SOTH LPGRS II THE 5195 SE ARCH I 3xoR2xEu.AS II °1"°'I 94P5 *181 CG*EG11ON TO I U HANGER REQUIRED BY SHEAR NO. otsaco 1 N/4-IOd TO PLY PANEL SCHEDULE .1 1 ASS PER SHEAR PANEL WfWA P EX PLY INTO IIDR4WN,JL&v. I 01455. 21(10 ELKS. 45 Of.. (s I? O.C. HiM) 1 I SHEET - 1W BOTH SIDES OP V(AI.I (LEE 2' NAILS ON PLY SIDE) 3. I F YP Tfl Q"n InwAl i ()fl S6B REFRIGERANT DISCLOSURE FORM Date: November 11 2019 - Carlsbad Permit# (if applicable):___________________ Business Name (Where system is located): Jimbos Complete Business Address: 1923 Calle Barcelona Phone: Refrigerant Contractor or Engineering Firm: ll{assmarni Corp Phone (909j 590-4910 Instructions: Column #1 Identify each refrigerant system included in this submittal. Column #2 List the chemical name of the refrigerant or the refrigerant number, CMC Factor. Column #3 Identify the refrigerant safety group. Refrigerant safety groups are defined in the California Mechanical Code (CMC). Column #4 Identify the total amount of refrigerant in each system (in pounds). If the amount in any single system is greater than 220 pounds of Group Al refrigerants or 30 pounds of any other Group, submit a refrigeration plan to the OcFA. Column 415 Does the refrigeration system have components located so that the leakage of refrigerant could enter a space occupied by any person? Example is a walk-in freezer or machine room. If yes, identify the volume of the smallest space occupied (in cubic feet). CMC Table 11-1 Column #6 Calculate by using: Column#4 divided by column #5 divided by 1000. If this value exceeds the CMC value for the specific refrigerant type, then submit a refrigeration plan, including a refrigerant alarm and detection system, to OCFA. Provide a copy of this form to the City Building Department. Column #7 Does the quantity of refrigerant exceed the amount specified in CMC Table il-i? If yes. Contact the local building department and OFCA for requirements. PROVIDE INFORMATION IN TABLE FORMAT Identify Refrigerant Safety Quantity Of Volume of Smallest Pounds of Does column Each Chemical Name Group Refrigerant Occupied Space Open Refrigerant #6 System OR (Pounds) To System (Cubic . per 1.000 Quantity Refrigerant Number! Cubic Feet of Exceed CMC Factor from CMC Enclosed Space Table 1102.2? (YIN) A4 R407A(Zeotropic Blend) Al 17.5 1,404 19 No A5 R-407A (Zeotropic Blend) Al 11.0 600 19 No BI R-407A (Zeotropic Blend) Al 21.0 2,331 19 No B2 R407A (Zeotropic Blend) Al 19.0 2,160 19 No B3 R-407A (Zeotropic Blend) Al " 20.0 1,728 19 No B4 R-407A (ZeotropicBlend) Al 23.0 2.178 19 No C2 R-407A (Zeotropic Blend) Al 19.5 2,376 '19 No Dl I R-407A (Zeotropic Blend) Al 14.0 990 19 No kj.1I' fl'e4f ii%- h3< lij Completed by (Print name and sign) Date Completed SAN DIEGO REGIONAL OFFICE USE ONLY qp-- HAZARDOUS MATERIALS RECORD ID # PLAN CHECK QUESTIONNAIRE BP DATE L- Business Name Business Contact Telephone # Jimbo's Naturally Jimbo Someck (858) 793-7755 Project Address City State Zip Code APN# 1923 Calle Barcelona Suite 149 Carlsbad CA 92009 255-012-04-00 Mailing Address City State Zip Code Plan File# 1923 Calle Barcelona Suite 149 Carlsbad CA 92009 Project Contact Applicant E-mail Telephone # Anthony Mansour tmansour@mansourarchitecture.com (858) 558-1509 The following questions represent the facility's activities, NOT the specific project description. PART I: FIRE DEPARTMENT -HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: (not required for prolects within the City of San Diego): Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Occupancy Rating: Facility's Square Footage (including proposed project): 18,088 SF Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 13. Corrosives Compressed Gases 6. Oxidizers 10. Cryogenics 14. OtbaLdealth Hazards Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials . None of These Flammable Solids 8. Unstable Reactives 12. Radioactives PART Ii: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISION (HMO): If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Avenue, Suite 110, San Diego, CA 92123. Call (858) 505-6700 prior to the issuance of a building permit. FEES ARE REQUIRED Project Completion Date: Expected Date of Occupancy: 0 CalARP Exempt YES NO (for new construction or remodeling projects) 0 IX] Is your business listed on the reverse side of this form? (check all that apply). Date Initials 0 lxi Will your business dispose of Hazardous Substances or Medical Waste in any amount? lxi 0 Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500 0 CalARP Required pounds and/or 200 cubic feet? 0 IX] Will your business store or handle carcinogens/reproductive toxins in any quantity? Date Initials 0 tEl Will your business use an existing or install an underground storage tank? IX] 0 Will your business store or handle Regulated Substances (CalARP)? 0 CalARP Complete 0 lx] Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? I 0 IN Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to Date Initials or greater than 1,320 gallons?(California's Aboveground _Petroleum _Storage Act). PART Ill: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCD): Any YES* answer requires a stamp from APCD 10124 Old Grove Road, San Diego, CA 92131 aocdcomo5isdcountv.ca.Qov (858) 586-2650). ["No stamp required if QI Yes and 03 Yes jnd 04-06 No]. The following questions are intended to identify the majority of air pollution issues at the planning stage. Projects may require additional measures not identified by these questions. For comprehensive requirements contact APCD. Residences are typically exempt, except - those with more than one building on the property; single buildings with more than four dwelling units; townhomes; condos; mixed-commercial use; deliberate bums; residences forming part of a larger project. [*Excludes garages & small outbuildings.] YES NO 0 lxi Will the project disturb 160 square feet or more of existing building materials? 0 IM Will any load supporting structural members be removed? Notification may be required 10 working days prior to commencing demolition. 0 0 (ANSWER ONLY IF QUESTION I or 2 IS YES) Has an asbestos survey been performed by a Certified Asbestos Consultant or Site Surveillance Technician? 0 0 (ANSWER ONLY IF QUESTION 3 IS YES) Based on the survey results, will the project disturb any asbestos containing material? Notification may be required 10 working days prior to commencing asbestos removal. 0 lxi Will the project or associated construction equipment emit air contaminants? See the reverse side of this form or APCD factsheet (www.sdaocd.oralinfo/factsloermits.odf) for typical equipment requiring an APCD permit. 0 0 (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school boundary Briefly describe business activities: I Briefly describe proposed project: Store and store fixtures I declare under penalty of perjury that to the best of my knowledge and belief tile responses made herein are true and correct. Anthony Mansour Name of Owner or Authorized Agent Signature of Owner or Authorized Agent Date FOR OFFICAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:__________________________________________________________________ BY: DATE:_J I EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR occuc COUNTY-HMD APCD COUNTY.HMD APCD COUNTY.HMD APCD "A stamp in this box onlv exempts businesses trom completing or updating a Hazardous Materials business Plan. Otfler permitting requirements may sail apply. HM-9171 (08/15) County of San Diego - DEH - Hazardous Materials Division Page 3of3 - 1 ProjectAddresslLocation: 1923 Calle Barcelona Suite 149, Carlsbad, CA 92009 Project Number: (For City use only) CHEMICAL CLASSIFICATION SUMMARY TABLE COMMON NAME CHEMICAL NAME % CONCENTRA- TION CAS # MATERIAL STATE (LIQUID! QUANTITY STORED SOLID! GAS) QUANTITY IN USE (OPEN! CLOSED) LOCATION (STORAGE & USE) HAZARDOUS CLASSIFICA- TIONS R448A _____________ Difuoromethane ____________ 26% ______________ 75-10-5 ____________ Liquefied Gas 13 _• 6001bs _____________ Jimbo's Del Mar _____________ Gases under pressure R448A Pentafluoroethan e 26% 35433-6 Liquefied Gas _____________ 6001bs Jimbo's Del Mar Gases under pressure R448A Tetrafluoroethan e 21% 811-97-2 Liquefied Gas 600 lbs Jimbo's Del Mar Gases under pressure R448A 2,3,3,3-Tetrafluor oprop 20% 754-12-1 Liquefied Gas 600 lbs Jimbos' Del Mar Gases under pressure R448A trans-i ,3,3,3-Tetr afluoroprop-i -ene 7% 29118-24-9 Liquefied Gas 600 lbs Jimbos Del Mar Gases under pressure [Clear Page 21 ENCINA WASTEWATER AUTHORITY INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY 6200 Avenida Encinas, Carlsbad, CA 92011 Phone: 760-438-3941 Fax: 760-476-9852 SourceControt@encinajpa.com Date: 10/23/19 Business Name:Jimbo's Naturally Street Address:1923 CalIe Barcelona Ste. 149, Carlsbad, CA 92009 Email Address:tmansour@mansourarchitecture.com PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT: (ON REVERSE SIDE CHECK TYPE OF BUSINESS) Check all below that are present at your facility: Acid Cleaning o Food Processing o Metal Powders Forming Assembly o Glass Manufacturing o Nutritional Supplement/Vitamin Automotive Repair o Industrial Laundry Manufacturing Battery Manufacturing o Ink Manufacturing o Painting/Finishing Biofuel Manufacturing o Laboratory o Paint Manufacturing Biotech Laboratory o Machining/Milling o Personal Care Products Bulk Chemical Storage o Membrane manufacturing Manufacturing Car Wash (i.e. water filter membranes) o Pesticide Manufacturing/ Packaging Chemical Manufacturing o Metal Casting/Forming o Pharmaceutical Manufacturing O Chemical Purification o Metal Fabrication (including precursors) Dental Offices o Metal Finishing o Porcelain Enameling Dental Schools Electroplating o Power Generation Dental Clinics Electroless Plating o Print Shop Dry Cleaning Anodizing o Research and Development Electrical Component Coating (i.e. phosphating) o Rubber Manufacturing Manufacturing Chemical Etching/Milling o Semiconductor Manufacturing Fertilizer Manufacturing Printed Circuit Board o Soap/Detergent Manufacturing Film/X-ray Processing Manufacturing o Waste Treatment/Storage New Business? Yes[] Noll SIC Code(s) if known: Date operation began/will begin:2003 Tenant Improvement? Yes IM No[] If yes, briefly describe improvement:Replace Existing Refrigeration System and Store Equipment Description of operations generating wastewater (discharged to sewer, hauled or evaporated):EXEMPT Estimated volume of industrial wastewater to be discharged (gal/ day): EXEMPT List hazardous wastes generated (type/volume): EXEMPT Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority? Yes 0 Date: EXEMPT No 11 Page 1 of 2 (cit y o f Carlsbad CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 Development Services Building Division 1635 Faraday Avenue (760) 602-2719 www.carlsbadca.gov PURPOSE This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their projects. The completed checklist must be included in the building permit application. It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances. NOTE: The following type of permits are not required to fill out this form + Patio I + Decks I + PME (w/o panel upgrade) + Pool 4 If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, an explanation must be provided to the satisfaction of the Building Official. 4 Details on CAP ordinance requirements are available on the city's website. 4 A CAP Building Plan template (form B-55) shall be added to the title page all building plane.. This template shall be completed to demonstrate project compliance with the CAP ordinances. Refer to the building application webøaae and download the latest form. Application Information Project Name/Building Permit No.: 3111W14;WP,4'j BP No.: Property Address/APN: Applicant Name/Co.: Applicant Address: Contact Phone: AN: 2*' Contact information of person completing this checklist (if different than above): Name: Contact Phone: Company name/address: Contact Email: Applicant Signature: Date:___________ B-50 Page 1 of 6 Revised 08/19 City of Carlsbad Climate Action Plan Consistency Checklist Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project. For alterations and additions to existing buildings, attach Building Permit Valuation workshe. Building Permit Valuation (BPV) qm worksheet: $_______________ Construction Type Complete Section(s) Notes: A high-rise residential building is 4 or more stories, including a U Residential Low-rise High-rise mixed-use building in which at least 20% of its conditioned floor area is residential use 0 New construction 2A, 3A, 4A IB 2B ,, 3B,4A 0 Additions and alterations: BPV < $60,000 N/A N/A All residential additions and alterations BPV ? $60,000 IA 4A 4A 1-2 family dwellings and townhouses with attached garages Electrical service panel upgrade only ' only *Multi-family dwellings only where interior finishes are removed BPV ? $200,000 IA, 4A* I B, 4A* and significant site work and upgrades to structural and mechanical, electrical, and/or Qlumbinq systems are proposed Nonresidential New construction I B, 2B, 3B, 4B and 5 J Alterations: BPV ~ $200,000 or additions a 1,000 a. 5 square feet BPV a $1,000,000 1B. 2B, 5 a 2,000 sq. ft. new roof addition 2B, 5 Building alterations of a 75% existing gross floor area I B also applies if BPV 2! $200,000 CAP Ordinance Compliance Checklist Item Check the appropriate boxes, explain all not applicable and exception items, and provide supporting calculations and documentation as necessary. 1. Energy Efficiency Please refer to Carlsbad Municipal Code (CMC) sections 18.21.155 and 18.30.190, and the California Green Building Standards Code (CALGreen) for more information when completing this section. A. U Residential addition or alteration? $60,000 building permit valuation. 0 N/A___________________________ See CMC section 18.30.190. 0 Exception: Home energy score a 7 (attach certification) Year Built Single-family Requirements Multi-family Requirements Before 1978 Select one: Duct sealing 0 Attic insulation 0 Cool roof 0 Attic insulation 1978 and later Select one: Lighting package 0 Water heating Package Between 1978 and 1991 Select one: 0 Duct sealing 0 Attic insulation 0 Cool roof Select one: 1992 and later 0 Lighting package 0 Water heating package rc'4W1 MWI, B. Nonresidential* new construction or alterations? $200,000 building permit valuation, ccrR r5r1. or additions? 1,000 square feet. N/A_14 Updated 8/15/2019 2 City of Carlsbad Climate Action Plan Consistency Checklist See CMC 18.21 .155 and CALGreen Appendix A5, Division A5.2 - Energy Efficiency. A5.203.1.1 Choose one: 0.1 Outdoor lighting 0.2 Warehouse dock seal doors 0.3 Restaurant service water heating (comply with California Energy Code section 140.5, as amended) N/A 0 A Daylight design PAFs 0.5 Exhaust air heat recovery A5.203.1.2.1 Choose one as applicable: 0.95 Energy budget 0.90 Energy budget X N/A_____________________________ A5.211.1 DOn-site renewable energy r,191 N/A______________________ A5211.3 0 Green power (if offered by local utility provider, 50% minimum renewable sources) A5212.1 0 Elevators and escalators J N/A_______________________ A5.213.1 0 Steel framing N/A_____________________ * Indudes hotels/motels and high-rise residential buildings For alterations? $1,000,000 BPV and affecting >75% existing gross floor area, or alterations that add 2,000 square feet of new roof addition: comply with CMC 18.30.130 instead. 2. Photovoltaic Systems U Residential new construction (for low-rise residential building permit applications submitted after 111120). Refer to 2019 California Energy Code section 150.1 (c)14 for requirements. Notes: 1) High-rise residential buildings are subject to nonresidential photovoltaic requirement (213 below) instead. 2) If project includes installation of an electric heat pump water heater pursuant to CMC 18.30.150(B) (high-rise residential) or 18.30.170(8) (low-rise residential), increase system size by .3kWdc if PV offset option is selected. Floor Plan ID (use additional CFA #d.u. sheets if necessary) Calculated kWdc* Exception 0 0 Total System Size: kWdc kWdc = (CFAx.572) I 1,000 + (1.15 x #d.u.) *Foula calculation where CFA = conditional floor area, #du = number of dwellings per plan we If proposed system size is less than calculated size, please explain. [] Nonresidential new construction or alterations 2$1,000,000 BPV and affecting 2750/6 existing floor area, or addition that increases roof area by 22,000 square feet. Please refer to CMC section 18.30.130 when completing this section. Note: This section also applies to high-rise residential and hotel/motel buildings. Choose one of the following methods: 0 Gross Floor Area (GFA) Method GFA: Mm. System Size: kWdc 0 If < 10,000s.f. Enter: 5 kWdc 0 If 2 10,000s.f. calculate: 15 kWdc x (GFN10,000) Round building size factor to nearest tenth, and round system size to nearest whole number. 0 Time- Dependent Valuation Method Updated 8/15/2019 3 City of Carlsbad Climate Action Plan Consistency Checklist Annual TDV Energy use:*** x.80= Min. system size: kWdc Attach calculation documentation using modeling software approved by the California Energy Commission. 3. Water Heating A. EJ Residential and hotel/motel new construction Please refer to CMC sections 18.30.150 and 18.30.170 when completing this section. 0 For systems serving individual dwelling units choose one: Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise residential only) Heat pump water heater AND PV system .3 kWdc larger than required in CMC section 18.30.130 (high rise residential hotel/motel) or CA Energy Code section 150.1(c) 14 (low-rise residential) O Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors 0 Exception: 0 For systems serving multiple dwelling units, install a central water-heating system with all of the following: Gas or propane water heating system Recirculation system per CMC 18.30.150(B) (high-rise residential, hotel/motel) or CMC 18.30.170(B) (low- rise residential) Solar water heating system that is either: .20 solar savings fraction O .15 solar savings fraction, plus drain water heat recovery 0 Exception: B. 0 Nonresidential new construction Please refer to Carlsbad Ordinance CMC section 18.30.150 when completing this section. 0 Water heating system derives at least 40% of its energy from one of the following (attach documentation): 0 Solar-thermal 0 Photovoltaics 0 Recovered energy Water heating system is (choose one): Heat pump water heater Electric resistance water heater(s) OSolar water heating system with .40 solar savings fraction 0 Exception: Updated 8/15/2019 4 City of Carlsbad Climate Action Plan Consistency Checklist 1 4. Electric Vehicle Charging 1 A LI Residential New construction and major alterations* Please refer to Carlsbad Ordinance CMC section 18.21.140 when completing this section. 0 One and two-family residential dwelling or townhouse with attached garage: 0 One EVSE Ready parking space required 0 Exception:_______________________________ 0 Multi-family residential: 0 Exception:________________________________ Total Parking Spaces Proposed EVSE Spaces Capable Ready Installed Total Calculations: Total EVSE spaces =10 x Total parking (rounded up to nearest whole number) EVSE Installed = Total EVSE Spaces x .50 (rounded up to nearest whole number) EVSE other= Total EVSE spaces - EVSE Installed (EVSE other may be Capable," Read or "Installed.") *Major alterations are: (1) for one and two-family dwellings and townhouses with attached garages, alterations have a building permit valuation k $60,000 or include an electrical service panel upgrade; (2) for multifamily dwellings (three units or more without attached garages), alterations have a building permit valuation a $200,000, interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed. B. D Nonresidential new construction (includes hotelslmotels) 0 Exception: Total Parking Spaces Proposed EVSE Spaces Capable Ready Installed Total Calculation: Refer to the table below: Total Number of Parking Spaces provided Number of required EV Spaces Number of required EVSE Installed Spaces 0-9 1 1 10-25 2 1 26-50 4 2 51-75 6 3 76-100 9 5 101-150 12 6 151-200 17 9 201 and over 10 percent of total 50 percent of Required EV Spaces Updated 8/15/2019 City of Carlsbad Climate Action Plan Consistency Checklist 5. Transportation Demand Management (1DM): Nonresidential ONLY An approved Transportation Demand Management (1DM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT. City staff will use the table below based on your submitted plans to determine whether or nor your permit requires a TDM plan. If TOM is applicable to your permit, staff will contact the applicant to develop a site-specific 1DM plan based on the permit details. Employee ADT Estimation for Various Commercial Uses Office (all)2 20 13 Restaurant 11 11 Retai13 8 4.5 Industrial 4 3.5 Manufacturing 4 3 Warehousing 4 1 i Unless otherwise noted, rates estimated from ITE Trip Generation Manual, 10Editi6n 2 For all office uses, use SANDAG rate of 20 ADT/1 ,000 sf to calculate employee ADT Retail uses include shopping center, variety store, supermarket, gyms, pharmacy, etc. Other commercial uses may be subject to special consideration Sample calculations: Office: 20,450 sf 1. 20,450 sf/1000 x 20 = 409 Employee ADT Retail: 9,334 sf First 1,000 sf = 8 ADT 9,334sf- 1,000sf=8,3345f (8,334 sf/1,000 x 4.5) + 8 =46 Employee ADT Acknowledgment: I acknowledge that the plans submitted may be subject to the my permit require a TOM plan and understand that an approy Applicant Signature: Person other than Applicant to be contacted for TDM Name (Printed): Email Address: 3r1 an s d's Transportaon Demand Management Ordinance. I agree to be contacted should acondiUonof permit issuance. Date: (if applicable): Phone Number Updated 8/15/2019 Zk cCity of CAP Building P1 Development Services an Building Division Carlsbad. Template 1635 Faraday Avenue 760-602-2719 B55 www.carlsbadca.gov INSTRUCTIONS: The following certificate shall be included on the title sheet of all building plans: CLIMATE ACTION PLAN (CAP) COMPLIANCE The following demonstrates project compliance with the applicable Climate Action Plan ordinances of the Carlsbad Municipal Code and California Green Building Standards Code (CALGreen), current version: ENERGY EFFICIENCY APPLICABLE: YES/No Complies with CMC 18.30.190. & 18.21.155 Yes/No Existing Structure, year built: Prepared Energy Audit? Yes/No Energy Score: Efficiency Measures included in scope: PHOTOVOLTAIC SYSTEM APPLICABLE: YES/NO Complies with CMC section 18.30.130 and 2019 California Energy Code section 150.1(c)14 Yes/No Required Provided Size of PV system (kWdc): Sizing PV by load calculations Yes/No If by Load Calculations: Total calculated electrical load: 80% of load: Hardship Requested Yes/No Hardship Approved Yes/No ALTERNATIVE WATER HEATING SYSTEM APPLICABLE: YES/NO Complies with CMC sections 18.30.150 and 18.30.170? Yes/No Alternative Source: Electric Passive Solar Hardship Requested Yes/No Hardship Approved Yes/No 4. ELECTRIC VEHICLE (EV) CHARGING APPLICABLE: YES/NO Complies with CMC section 18.21.140? Yes/No Panel Upgrade? Yes/No Required Provided Total EV Parking Spaces: No. of EV Capable Spaces: No. of EV Ready Spaces: No. of EV Installed Spaces: Hardship Requested Yes/No Hardship Approved Yes/No S. TRAFFIC DEMAND MANAGEMENT APPLICABLE: YES/No Compliant? Yes / no TDM Report on file with city? Yes / no