0/0911999 Residential Permit Permit No:CB991456
Building Inspection Request Line (760) 438-3101
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
136 SEQUOIA AV CBAD
RESDNTL Sub Type: SFD
2060110600 Lot#: 6
$334,681.00 Construction Type: VN
6 Reference #:
I Structure Type: SFD
4 Bathrooms: 3
SFD 3836 SF, GAR 775 SF,BALC I
DEMO EXISTING SFD AND BUILD NEW SFD
Status: APPROVED
Applied: 04/14/1999
Entered By: JM
Plan Approved: 06/08/1999
Issued:
Inspect Area:
Orig PC#:
Plan Check#:
Applicant: Owner:
BLACKFORD, ROY R. JONES GERALD P&MYRNA K TRS
P 0 BOX 952
2942 HARDING STREET #E CARLSBAD CA
CARLSBAD, CA 92008 92018
619-729-0553
Total Fees: $3,613.68 Total Payments To Date: $938.33 Balance Due: $2,675.35
Building Permit $1,443.58 Red. Water Con. Fee $0.00
Add'l Building Permit Fee $0.00 Meter Size
Plan Check $938.33 Add'l Red. Water Con. Fee $0.00
Add'l Plan Check Fee $0.00 CFD Payoff Fee $0.00
Plan Check Discount $0.00 PFF $0.00
Strong Motion Fee $33.47 PFF (CFD Fund) $0.00
Park in Lieu Fee $0.00 License Tax $0.00
Park Fee $0.00 License Tax (CFD Fund) $0.00
LFM Fee $0.00 Traffic Impact Fee $0.00
Bridge Fee $0.00 Traffic Impact (CFD Fund) $0.00
Other Bridge Fee $0.00 LFMZ Transportation Fee $0.00
BTD #2 Fee $0.00 PLUMBING TOTAL $217.00
BTD #3 Fee $0.00 ELECTRICAL TOTAL $60.00
Renewal Fee $0.00 MECHANICAL TOTAL $67.50
Add'I Renewal Fee $0.00 Housing Impact Fee $0.00
Other Building Fee $0.00 Housing lnLieu Fee $0.00
Pot. Water Con. Fee $0.00 Master Drainage Fee: $853.80
Meter Size Sewer Fee: $0.00
Add'l Pot. Water Con. Fee $0.00 TOTAL PERMIT FEES $3,613.68
FINAL APPROVAL-S
Inspector: Date: _____________ Clearance:
NOTICE: Please take NOTICE that apprd oTyour project includes the'Imposition' of fees, dedications, reservations, or other exactions hereafter collectively
referred to as fees/exactions.' You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactly
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired.
- V2197q
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
2075 Las Palmas Dr., Carlsbad CA 92009
(760) 438-1161 •
FOR OFFICE USE ONLY
PLAN CHECK NO.__________
EST. VAL.
Plan Ck. Deposit
Validated By (
1. PROJECT INFORMATION
J)(P 4MCKU018 AVG7 C --- PRHT 9$33 Address (include Bldg/Suite #) Business Name (at this address)
TRACT 1141 fLJA
Legal Description Lot No. Subdivision Name/Number Unit No. Phase No. Total # of units
Assessor's Parcel // Existing Use 3r d Use
-
S1 4 3
Des iption-of-Work----------- - - - SQ. FT. #of Stories of Bedroom # of Bathrooms
775 &h f12-
........--------- ..............
sow R . C4D 4*3t 'Wt ' 7' 114O 1W 4i4 Name Address City State/Zip Telephone W
3, APPLICANT 0 Contractor 0 Agent for cor WnO_nt 1D Agent for Owner
—.-----
. Name Address City State/Zip Telephone #
Name ' ' I - Address ' City State/Zip Telephone #
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
[Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged
exemptipn. Arty violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001).
Address State/Zip Telephone #
State License # License Class City Business License #
Designer Name Address City State/Zip Telephone
State License #
[67W_WORKERS' COMPENSATION ..... .
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My worker's compensation insurance carrier and policy number are:
Insurance Company Policy No._____ Expiration Date__________________
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($1001 OR LESS)
CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars ($100,000). in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees.
SIGNATURE DATE
7. OWNER.BUILDERDECLARATION______
I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
I am exempt under Section Business and Professions Code for this reason:
I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ONO
I (have / have not) signed an application for a building permit for the proposed work.
I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number I contractors license number):
I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address I phone
number / contractors license number):
I will provide some of the work; but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work):
PROPERTY OWNER SIGNATURE DATE
LcorviPth THIS SECTiON FOR NON RESIDENJ7AL BUILDING PERMIT ONLY -
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES 0 NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES 0 NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
S. CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code).
LENDER'S NAME LENDER'S ADDRESS_______________________________________________________
L%. APPLICANT CERIFCATI0N
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citi of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS. COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or
work authorized by such permit is nol commenc d ithin 3Eeriod
ys from the date of such permit or if the building or work authorized by such permit is suspended
or abandoned at any time afiF
ffi-
e d or of 180 d ys Section 10 4.4 Uniform Building Code).
APPLICANT'S SIGNATURE 1ø't4 VM3 DATE
WHITE: File YELLOW: Applicant PINK: Finance
Inspection List
Permit#: CB991456 Type: RESDNTL SFD SFD 3836 SF, GAR 775 SF,BALC I
DEMO EXISTING SFD AND BUILD NEW SF
Date Inspection Item Inspector Act Comments
4/12/2000 14 Frame/Steel/Bolting/Weldin DM AP
3/6/200089 Final Combo DM NR SEE NOTICE ATTACHED
3/3/200089 Final Combo DM CO
3/2/200089 Final Combo DM CO
2/17/2000 89 Final Combo DM NR
2/8/200089 Final Combo DM CO
12/3/1999 23 Gas/Test/Repairs OM AP
11/9/1999 17 Interior Lath/Drywall DM AP
11/9/1999 18 Exterior Lath/Drywall DM AP
11/8/1999 17 Interior Lath/Drywall DM CO SEE NOTICE ATTACHED
10/27/1999 16 Insulation DM AP
10/26/1999 16 Insulation DM NR
10/25/1999 18 Exterior Lath/Drywall DM WC
10/25/1999 84 Rough Combo DM AP
10/21/1999 84 Rough Combo DM NR
10/19/1999 84 Rough Combo DM CO
10/5/1999 13 Shear Panels/HD's DM AP
9/30/1999 22 Sewer/Water Service DM NR
9/29/1999 13 Shear Panels/HD's DM CO
9/29/1999 16 Insulation DM CO
9/29/1999 34 Rough Electric DM CO
9/27/1999 13 Shear Panels/HD's DM NR
9/27/1999 15 Roof/Reroof DM AP
8/20/1999 13 Shear Panels/HD's DH AP STRAPS AT SUB FLOOR
8/20/1999 66 Grout DH AP
8/13/1999 34 Rough Electric DH CA
8/9/199932 Const. Service/Agricultural DH AP PERMIT #992951
8/9/199961 Footing DH AP
7/22/1999 11 Ftg/Foundation/Piers DH AP
7/21/1999 11 Ftg/Foundation/Piers DH NR
7/13/1999 21 Underground/Under Floor OH AP
Friday, August 25, 2000 Page 1 of 1
City of Carlsbad Bldg Inspection Request
For: 4/12/2000
Permit# CB991456 Inspector Assignment: DM
Title: SFD 3836 SF, GAR 775 SF,BALC I
Description: DEMO EXISTING SFD AND BUILD NEW SFD
Type: RESDNTL Sub Type: SFD
Job Address: 136 SEQUOIA AV
Suite: Lot 6
Location: -
APPLICANT BLACKFORD, ROY R.
Owner: JONES GERALD P&MYRNA K TRS
Remarks: 9AM PLEASE - CONCRETE COMING @ lOAM
Total Time:
CD Description Act Comments
14 Frame/Steel/Bolting/Welding
Associated PCRs
Phone: 7608027107
Inspector:
Requested By: GARTH
Entered By: CHRISTINE
Inspection History
Date Description
3/6/2000 89 Final Combo
3/3/2000 89 Final Combo
3/2/2000 89 Final Combo
2/17/2000 89 Final Combo
2/8/2000 89 Final Combo
12/3/1999 23 Gas/Test/Repairs
11/9/1999 17 Interior Lath/Drywall
11/9/1999 18 Exterior Lath/Drywall
11/8/1999 17 Interior Lath/Drywall
10/27/1999 16 Insulation
10/26/1999 16 Insulation
10/25/1999 18 Exterior Lath/Drywall
10/25/1999 84 Rough Combo
10/21/1999 84 Rough Combo
10/19/1999 84 Rough Combo
10/5/1999 13 Shear Panels/HD's
9/30/1999 22 Sewer/Water Service
9/29/1999 13 Shear Panels/HD's
9/29/1999 16 Insulation
9/29/1999 34 Rough Electric
9/27/1999 13 Shear Panels/HD's
9/27/1999 15 Roof/Reroof
Act lnsp Comments
NR DM SEE NOTICE ATTACHED
CO DM
CO DM
NR DM
CO DM
AP DM
AP DM
AP DM
CO DM SEE NOTICE ATTACHED
AP DM
NR DM
WC DM
AP DM
NR DM
CO DM
AP DM
NR DM
CO DM
CO DM
CO DM
NR OM
AP DM
2/8/2000
City of Carlsbad
Final Building Inspection
/ .__.__%i Dept: Buildin Engineering rlanning CMWD St Lite Fire
PIn ('hpk I Date:
Permit #: CB991456 Permit Type: RESDNTL
Project Name: SFD 3836 SF, GAR 775 SF,BALC 1 Sub Type: SFD
DEMO EXISTING SFD AND BUILD NEW SFD
'Address: 136 SEQUOIA AV Lot: 6
Contact Person: CATHI Phone: 0000000000
Sewer 01st: CA Water 01st: CA
Inspected Date-
By: Inspected; 3/3/00 Approved: Disapproved:
Inspected Date
By: Inspected: Approved: Disapproved:
'inspected Date
By: Inspected: Approved: ______ Disapproved:
Comments:
d 1flL
- . ijiii A fi
(L'üy of CarL i'ad - -
amusminol,Ivc, Catt,ad Caflfoqii 92009
S
INPEC1I0N RECORD
INSPECTION RECQRD CARD-WITH APPROVE!) PLANS .- -
:MUST-or KEPVON THE JOB '
CALL PRIOR 10 .20 P.M FOR NEXT WORK)AYJN5PECflON
- "BU LDIR1 INSPECTION (760)
NOJWffL-
J -
- :. ...
9145G 136SE4ZLJOIAAVcBAD I-- - . . - - •-: -
- SF1) 3836 SF• GAR 775 SF.BALC I
U OEMO EXISTING SF1) AND BUILD NEW SFD -
1YPE CONET. - - - DATtIf (I!
- - I REINTh SF0 - CONTRACIOR- - - --
- - BUILDI LøIft 6 SLACKFOFU3. ROY Rofm . I -: - - - - . -. - -• • -. -
:- - -
- •-- --• -'-APPROVED!OCOVER '-.-• -. Notes - -
WING zaW : 4// (1*G CâdO
t:REINFORaDSrL -::- :.'-i-./ -• '--- - -. !-: .' --. ---?-
?:MONRY-- ..---:- -bil9-
ROUTstaWAUoRNNS
- - - - "' •f' - - -
•l-
---: -- --
COUjMN FOOTINGS
:- -- .------ •- • - -;:
R0OA1)flNG: -.'-- . . -:.•- -. ou- . - Ame :--
.00rSHEARPAN&S-
.:a---- :
IIULATNXv!- ,. - .+..- •. -: ,-• -- ••••
-'• -. -- ; - ____
:'(IINTERIQRLAD4&DRYWAtL - 143 .. ________ -. -- - •- :,- fr-
WAt(D-BLIcO
eq,
'VCO *fl4Dc*BiNDWffE. .OWAWL. . -- ..--------.- .'•-• - - ---. •
TOP OUT A5TE -- !WA1ER
JWPAN
-. -
- -.( • --_,---.:
GS5TF*SP0ING
0 WAlER HMl1Z 0 SOW WATER i. - -*- ' •.- r
- •--: .-• -- - :-'.- ---
-.-ç,- : - - - --- -. - - - - -
-
&EC!RICUNPERGROUNDD UFER
RPUci..'ZIL,- - - •- - --. -. -:- -
- :. ,,.. -. .•.- ...
PEUTRIC$9%VI
1OBO4DINGDPO? ;;---:-I..?.;. ... - - -:--- -- :
---: - - :-: - -
DUC1S & FIPING r Y$i - OUC RtU-R PIPNC - - -'1
- - - - :-,-- -'- - v'- -- - - - ::- - -:- -•
-----u oi15pIOON W%PPROPP ,1rnwsAaoi 4w8IAovm :-s- - - - -- --'--
i-in I
: 6uiIdbk 47ii-4 74 43& ---- - - -
OI4WD - -- 43722f71S3- -- -'aZ • - -
- - I - -- - - -. '-- -
d LKE 6' 89& s3uw U411A14 am Amm P:S8 -ø-!w
-.
•.
Ear
echnics. P.0, Box 891989 ec Earth Technics (909) 699-5451
M~!
- Temecula, CA 92589
CLIENT Job # _ggj4 Date -711 ______
Project Location: (% seouofs kg Tract No.___________
Grading Permit No:___________ Lot No.________
Subject: 1r,4 '
i(a rPcr 04 - • t'o 4(ç
JOIMAXE jtO Ri
C&r46Xf4W&E, Willi
(t)( o1)-$ Za:c- )q• •
41
ouS.
- 4_ ,• -
ç E r17k fr.q7cQ • •
-
By:.
ENGINEERING FILE . WHITE FIELD FILE . YELLOW JOB SUPERINTENDENT. PINK
EsGil Corporation
In Partnership with government for fliui(ding Safety
DATE: 06/04/99 UAP R6CALSIT
JURIS.
JURISDICTION: Carlsbad EVIEWER
0 FILE
PLAN CHECK NO.: 99-1456 '1' SET: II
PROJECT ADDRESS: 136 Sequoia Ave.
PROJECT NAME: SFD/Garage for Jones Residence
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficincies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
fl The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
fl The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
fl The applicant's copy of the check list has been sent to:
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: ) Fax #:
Malt Telephone Fax In Person
j REMARKS:
By: Ray Fuller Enclosures:
Esgil Corporation
DGA.DMB DEJ DPC 05/27/99 tmsmtl.dot
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (619) 560-1468 • Fax (619) 560-1576 -
EsGil Corporation
In Partnership with government for Wuitling Safety
DATE: 04/27/99
JURISDICTION: Carlsbad
PLAN CHECK NO.: 99-1456
PROJECT ADDRESS: 136 Sequoia Ave.
SET:I
O APPLICANT
OPtSRE VIEWER
0 FILE
PROJECT NAME: SFD/Garage for Jones Residence
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete. recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Roy Blackford
2942 Harding St. "E" Carlsbad, Ca. 92008
Esgil Corporation staff did not advise the applicant(except .by mail) that the plan check has
been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: ) Fax #:
Mail Telephone Fax In Person
REMARKS:
By: Ray Fuller Enclosures:
Esgil Corporation
DGA 0MB DEJ F1 PC 04/19/99 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (619) 560-1468 • Fax(619)560-1576
Carlsbad 99-1456
04/27/99
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLANCHECK NO.: 99-1456 JURISDICTION: Carlsbad
PROJECT ADDRESS: 136 Sequoia Ave.
do
FLOOR AREA:
Dwelling 3836
Garage 775
Decks 192
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 04/14/99
DATE INITIAL PLAN REVIEW
COMPLETED: 04/27/99
STORIES: 2
HEIGHT: 25
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 04/19/99
PLAN REVIEWER: Ray Fuller
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinance by the Planning Department, Engineering Department, Fire
Department or other departments. Clearance from those departments may be required prior to
the issuance of a building permit.
Present California law mandates that residential construction comply with Title 24 and the
following model codes: 1994 UBC (effective 12/28/95), 1994 UPC (effective 12/28/95), 1994
UMC (effective 2/23/96) and 1993 NEC (effective 12/28/95).
The above regulations apply to residential construction, regardless of the code editions adopted
by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1994 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans..
LIST NO. 1, GENERAL SINGLE FAMILY DWELLINGS AND DUPLEXES WITHOUT SUPPLEMENTS (1994 UBC) r3forw.dot
Carlsbad 99-1456
04/27/99
macvalue.doc 5196
Carlsbad 99-1456
04/27/99
. PLANS
1. Please make all corrections on the original tracings, as requested in the correction
list.
Submit three sets of plans for commercial/industrial projects (two sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
Deliver all corrected sets of plans and calculations/reports directly to the
City of Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA
92009, (760) 438-1161. The City will route the plans to EsGil Corporation and the
Carlsbad Planning, Engineering and Fire Departments.
Bring one corrected set of plans and calculations/reports to EsGil
Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (619)
560-1468. Deliver all remaining sets of plans and calculations/reports directly to
the City of Carlsbad Building Department for routing to their Planning, Engineering
and Fire Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not
be reviewed by the City Planning, Engineering and Fire Departments until review
by EsGil Corporation is complete.
. FIRE PROTECTION
2. Show locations of permanently wired smoke detectors with battery backup:
a) Inside each bedroom. Study and bedroom 3 on page 13
. GENERAL RESIDENTIAL REQUIREMENTS
3. Openable window area in habitable rooms must be 1/20 of the floor area and a
minimum of 5 square feet. Section 1203.3. Study on page 5 needs 11 V sg ft of
openable.
4. Dumb waiter shown on page 8 needs to show 5/8 x shaft to roof sheathing or a
full 1 hour termination at ceiling. This would mean 2 x 's shown with a layer of 5/8
X on top also. No 1 hr door is shown for door 29 on door schedule.
5. Glazing in the following locations should be of safety glazing material in
accordance with Section 2406.4 (see exceptions):
a) Doors and enclosures for hot tubs, whirlpools, saunas, steam rooms,
bathtubs and showers and in any portion of a building wall enclosing these
compartments where the bottom exposed edge of the glazing is less than
60 inches above a standing surface and drain inlet. Window KI master bath
pages.
Carlsbad 99-1456
04/27/99
Fixed or operable panels adjacent to a door where the nearest exposed
edge of the glazing is within a 24-inch arc of either vertical edge of the door
in a closed position and where the bottom exposed edge of the glazing is
less than 60 inches above the walking surface. Window G at entry page 4.
Walls enclosing stairway landings or within 5 feet of the bottom and top of
stairways where the bottom edge of the glass is less than
60 inches above a walking surface. Windows H page 4 and GI page 5
EXITS, STAIRWAYS, AND RAILINGS
Guardrails (Section 509.1):
a) Openings between railings shall be less than 4". Pipe railing shown on
elevations
Note that minimum head room is 6'8".
How are exterior stairs constructed? Are these open risers or if they are
fenclosed show slope and water proofing.
ROOFING & DECKS
Specify minimum 1/4 inch per foot deck slope for drainage and specify how
obtaining slope. (Sleepers ?) Sections 1506.1 and 1605.6.
Show size of roof drains and overflows. Sections 1506.2 and 1506.3.
An occupancy separation is not required between carport and residence,
provided the carport is open on two or more sides and has no enclosed uses
above. Section 302.1. Clearly show that carport has stucco underneath on
building section shown on page 8.
FOUNDATION REQUIREMENTS
Investigate the potential for seismically induced soil liquefaction and soil
instability in seismic zones 3 and 4. Section 1804.5
Per soils report, note on the plan the soils classification, whether or not the soil is
expansive and note the allowable bearing value. Section 1804.3.
Show size and embedment of hold down anchors on foundation plan or note
SSTB sizes for each type. Section 106.3.3.
Carlsbad 99-1456
04/27/99
FRAMING
15. Provide truss details and truss calculations for this project. Specify truss
identification numbers on the plans. Truss layout needs to be reviewed and
stamped by a licensed designer. All truss to truss connections must be specified
on plans.
16. Show length of shear panels at locations and hold downs required by
calculations. Missing hold downs in various locations such line 2 and 4. Detail
and reference floor ties where required.
17. Per UBC Section 2343.6, provide the following note on the plans if trusses are
used: "Each truss shall be legibly branded, marked or otherwise have
permanently affixed thereto the following information located within 2 feet of the
center of the span on the face of the bottom chord:
Identity of the company manufacturing the truss.
The design load..
The spacing of the trusses."
18. Truss calculations need to reflect 4' openings for skylights.
19. A complete structural check cannot be done till vertical and lateral calculations
reflect the additional dead loads mentioned below.
20. Provide calculations for main vertical and horizontal framing members and
footings. Section 106.3.3. The calculations provided did not take into affect the 3"
of light weight concrete shown on page 8. TJl's and other framing members in
carport area do not reflect the weight of the stucco at soffitt area.
21. Provide calculations for lateral loads, shear panels, shear transfer and related.
Section 106.3.3. The additional weight mentioned above will effect the lateral
also.
22. Could not locate RB I on page 7. Assume its shown as RB 10 but it only
measures 10 ft instead of 11 %' shown on page 2 of calculations.
23. Does FB 10 point load 2 reflect point load from girder truss above and from FB
8?
.. MECHANICAL (UNIFORM MECHANICAL CODE)
24. Note on the plans that the FAU closet or alcove must be 12 inches wider than
the furnace or furnaces being installed. UMC Section 315.1. Page 4 at hallway.
25. Provide dryer vent to outside. The maximum length is 14 feet with two 90-degree
elbows. UMC, Section 504.3.2.
Carlsbad 99-1456
04/27/99
. CARLSBAD S.F.D. & DUPLEX SUPPLEMENT
New residential units must be pre-plumbed for future solar water heating. Note
that two roof jacks must be installed where the water heater is in the one story
garage and directly below the most south facing roof (City Ordinance No. 8093).
Note that two 3/4" copper pipes must be installed to the most convenient future
solar panel location when the water heater is not in a one story garage and is not
directly below the most south facing roof. (City Ordinance No. 8093).
All piping for present or future solar water heating must be insulated when in areas
that are not heated or cooled by mechanical means (city policy).
All structures require a Class A roof covering, except room additions. If a room
addition covers all of the existing building (2nd story addition), then the above
exception doesn't apply. (Note comp roof is Class A)
Overflow roof drains shall terminate in an area where they will be readily visible
and will not cause damage to the building. If the roof drain terminates through a
wall, the overflow drain shall terminate 12" minimum above the roof drain. Policy
84-35.
To speed up the review process, note on this list (or a copy) where each correction
item has been addressed, i.e., plan sheet, note or detail number, calculation page,
etc.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly describe
them and where they are located in the plans.
Have changes been made to the plans not resulting from this correction list?
Please indicate:
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468,
to perform the plan review for your project. If you have any questions regarding
these plan review items, please contact Ray Fuller at Esgil Corporation. Thank
you.
Carlsbad 99-1456
04/27/99
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK NO.: 99-1456
PREPARED BY: Ray Fuller DATE: 04/27/99
BUILDING ADDRESS: 136 Sequoia Ave.
BUILDING OCCUPANCY: R3 Ui TYPE OF CONSTRUCTION: VN
BUILDING PORTION BUILDING AREA
(ft.2)
VALUATION
MULTIPLIER
VALUE
($)
Dwelling 3836 82.00 314,552.00
Garage 775 23.00 17,825.00
Decks 192 12.00 2,304.00
Air Conditioning 1 3836 3.00 11,508.00
Fire Sprinklers
TOTAL VALUE .
346,189.00
E 199 UBC Building Permit Fee 0 Bldg. Permit Fee by ordinance: $ 1485.58
D 199 UBC Plan Check Fee Z Plan Check Fee by ordinance: $ 965.62
Type of Review: Complete Review Structural Only Hourly
O Repetitive Fee Applicable Other:
Esgil Plan Review Fee: $ 772.50
Comments: 94 UBC = $2122.25 x 70% = $1485.58 x 52% = $772.50
Plan check fee $1485.58 x 65% = $965.62
Sheet 1 of 1
City of Carlsbad
BUILDING PLANCHECK CHECKLIST
DATE: s)c/gg PLANCHECK NO.:
BUILDING ADDRESS: 13
PROJECT DESCRIPTION: .5J
CB7-/L/$
ASSESSOR'S PARCEL NUMBER: OI().. C2 EST. VALUE:
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved. The approval is based on plans,
information and/or specifications provided in your
submittal; therefore any changes to these items after
this date, including field modifications, must be
reviewed by this office• to insure continued
conformance with applicable codes. Please review
carefully all comments attached, as failure to comply
with instructions in this report can result in
suspension of permit to build.
A Right-of-Way permit is required prior to
construction of the following improvements:
DENIAL
Please see% ttached report of deficiencies
marked wi In. M e necessary corrections to plans
or speci s for compliance with applicable
codes and standards. Submit corrected plans and/or
specifications to this office for review.
( - z'j Date: __
By: Date:
By: Date:
ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT:
By: 777 777a Date: -6
ATTACHMENTS ENGINEERING DEPT. CONTACT PERSON
Dedication Application Name: David Rick
Dedication Checklist City of Carlsbad
Improvement Application
Improvement Checklist
Future Improvement Agreement
Grading Permit Application
Grading Submittal Checklist
Right-of-Way Permit Application
Right-of-Way Permit Submittal Checklist
and Information Sheet
Sewer Fee Information Sheet
Address: 2075 Las Palmas Dr., Carlsbad, CA 92009
Phone: (619) 438-1161, ext. 4324
CFI) INFORMATION
Parcel Map No:
Lots:
Recordation:
Carlsbad Tract:
A-4
PlaT.thec C1st DP0001 Fomi M
Rev.93I972O75 Las Palmas Dr. • Carlsbad, CA 920091576. (619) 438-1161 • FAX (619) 438-0894
BUILDING PLANCHECK CHECKLIST
I
, \
SITE PLAN
2' 3RDI
I' U U 1. Provide a fully dimensioned site plan drawn to scale. Show:
North Arrow Property Lines
'. Existing & Proposed Structures
IF.
Easements
C. Existing Street Improvements Right-of-Way Width & Adjacent Streets
Driveway widths
I U 0 2. Show on site plan:
A. Drainage Patterns
Building pad surface drainage must maintain a minimum slope of one
percent towards an adjoining street or an approved drainage course.
ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive
drainage of 2% to swale 5' away from building."
B. Existing & Proposed Slopes and Topography
Or/ U U 3. Include on title sheet:
Site address
Assessor's Parcel Number
Legal Description
For commercial/industrial buildings and tenant improvement projects, include:
total building square footage with the square footage for each different use,
existing sewer permits showing square footage of different uses (manufacturing,
warehouse, office, etc.) previously approved.
EXISTING PERMIT NUMBER DESCRIPTION
DISCRETIONARY APPROVAL COMPLIANCE
U U 4a. Project does not comply with the following Engineering Conditions of approval for
ProjectNo.________________________________________________________
U U U 4b. All conditions are in compliance. Date:
Pantheck Cklst BP000I Form OR.doc Rev. 913197
BUILDING PLANCHECK CHECKLIST
DEDICATION REQUIREMENTS
5. Dedication for all street Rights-of-Way adjacent to the building site and any storm
drain or utility easements on the building site is required for all new buildings and
for remodels with a value at or exceeding $_, pursuant to Carlsbad
Municipal Code Section 18.40.030.
Dedication required as follows:
Dedication required. Please have a registered Civil Engineer or Land Surveyor
prepare the appropriate legal description together with an 8 1/2" x 11" plat map
and submit with a title report. All easement documents must be approved and
signed by owner(s) prior to issuance of Building Permit. Attached please find an
application form and submittal checklist for the dedication process. Submit the
completed application form with the required checklist items and fees to the
Engineering Department in person. Applications will not be accept by mail or fax.
Dedication completed by: Date:
IMPROVEMENT REQUIREMENTS
U 6a. All needed public improvements upon and adjacent to the building site must be
constructed at time of building construction whenever the value of the
construction exceeds $ , pursuant to Carlsbad Municipal Code
Section 18.40.040.
Public improvements required as follows:
Attached please find an application form and submittal checklist for the public
improvement requirements. A registered Civil Engineer must prepare the
appropriate improvement plans and submit them together with the requirements
on the attached checklist to the Engineering Department through a separate plan
check process. The completed application form and the requirements on the
checklist must be submitted in person. Applications' by mail or fax are not
accepted. Improvement plans must be approved, appropriate securities posted
and fees paid prior to issuance of building permit.
/ Improvement Plans signed by: Date:
9/ U 6b. Construction of the public improvements may be deferred pursuant to Carlsbad
Municipal Code Section 18.40. Please submit a recent property title report or F1 cLc.., p.Dr current grant deed on the property and processing fee of $ b2O so
, . we may prepare the necessary Future Improvement Agreement. This agreement
must be signed, notarized and approved by the City prior to issuance of a
Building permit.
Future public improvements required as follows:
Flantheck Clint 8P000I Form OR.doc Rev. 913197
- V
'
BUILDING PLANCHECK CHECKLIST
1' 2*' 3rd/
U U U 6à. Enclosed please find your Future Improvement Agreement. Please return
agreement signed and notarized to the Engineering Department.
Future Improvement Agreement completed by:
Date:
O U U 6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective
improvements found adiacent to building site must be repaired to the satisfaction
of the City Inspector prior to occupancy.
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for a grading permit are found in Section
11.06.030 of the Municipal Code.
U U U 7a. Inadequate information available on Site Plan to make a determination on grading
requirements. Include accurate grading quantities (cut, fill import, export).
0 U U 7b. Grading Permit required. A separate grading plan prepared by a registered Civil
Engineer must be submitted together with the completed application form
attached. NOTE: The Grading Permit must be issued and rough grading
arovaI obtained prior to issuance of a Building Permit.
Grading Inspector sign off by: Date:
U U U 7c. Graded Pad Certification required. (Note: Pad certification may be required even
if a grading permit is not required.)
/U U 7d.No Grading Permit required.
U U U 7e. If grading is not required, write "No Grading" on plot plan.
MISCELLANEOUS PERMITS
U U U 8. ARIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or
private work adjacent to the public Right-of-Way. Types of work include, but are
not limited to: street improvements, tree trimming, driveway construction, tieing
into public storm drain, sewer and water utilities.
Right-of-Way permit required for:
elanthed, Ckist BP000I Fwm MM.doc 4 Rev. O91l97
BUILDING PLANCHECK CHECKLIST
2nd." 3rd/
0 9. A SEWER PERMIT is required concurrent with the building permit issuance. The
fee is noted in the fees section on the following page.
0 0 10. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad
sewer service area, you need to contact the Carlsbad Municipal Water District,
located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can
provide forms and assistance, and will check to see if your business enterprise is
on the EWA Exempt List. You may telephone (760) 438-2722, extension 153, for
assistance.
Industrial Waste permit accepted by:
Date:
0 0 11. NPDES PERMIT
Complies with the City's requirements of the National Pollutant Discharge
Elimination System (NPDES) permit. The applicant shall provide best
management practices to reduce surface pollutants to an acceptable level prior to
discharge to sensitive areas. Plans for such improvements shall be approved by
the City Engineer prior to issuance of grading or building permit, whichever
occurs first.
ZRequired fees are attached
0 No fees required
Additional Comments:
re
Ir j
J.
P&antheck dust BP0001 Form DR.doc Rev. 913197
ENGINEERING DEPARTMENT
FEE CALCULATION WORKSHEET
Estimate based on unconfirmed information from applicant.
Calculation based on building plancheck plan submittal.
Address: (3. Bldg. Permit No. C 'p7.. 111c
Prepared by: t.Rc LA- Date: '5.7-_cl ct Checked by: Date:
EDUCALCULATIONS: List types and square footages for all uses.
Types of Use: Sq. Ft./Units: EDU's:
Types of Use: Sq. Ft./Units: EDU's:
ADTCALCULATIONS: List types and sqUare footages for all uses.
Types of Use: Sq. Ft./Units: ADT's:
Types of Use: Sq. Ft./Units: ADI's:
FEESREQUIRED:
WITHIN CFD: DYES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) 0 NO
1. PARK-IN-LIEU FEE PARK AREA & #:
FEE/UNIT: X NO. UNITS: = $____________
2. TRAFFIC IMPACT FEE
ADT's/UNITS: X FEE/ADT:
ZONE TRANSPORTATION ADT'S X $10
3. BRIDGE AND THOROUGHFARE FEE (DIST. #1 DIST. #2 01ST. #3
ADTs/UNITS:_ X FEE/ADT: =$
4. FACILITIES MANAGEMENT FEE ZONE:_________
UNIT/SQ.FT.: X FEE/SQ.FT./UNIT: =$
5. SEWER FEE
PERMIT No.
EDU's: X FEE/EDU: = $_______________
BENEFIT AREA: DRAINAGE BASIN:_______
EDU's: X FEE/EDU: =$______________
6. SEWER LATERAL ($2,500) =$___________
7. DRAINAGE FEES PLDA 6': HIGH /LOW______
ACRES: X FEE/AC: 5C4'2
TOTALOFABOVEFEES*: $______________
*NOTE: This calculation sheet is NOT a complete list of all fees which may be due.
Dedications and Improvements may also be required with Building Permits.
P:DOCSMISFORMSFEE CALCULATION WORKSHEET REV 4/29/99
C16
SIN
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No. CB q I 1f Address 1 S 6 5e t, t..ço i'a A v.
Planner '11 C(.Ld GO ALV (fl Phone (619) 438-1161, extension H329
APN:0GO1l'OC'00
Type of Project & Use: Net Project Density: DU/AC
Zoning: 1fl General Plan:¶ I-I Facilities Management Zone: _________
CFD (in/tint) #Date of participation: Remaining net dev acres:______ Circle One
(For non-residential development: Type of land used created by
thispermit:_________________________________________________________
1171 Legend: Item Complete
X E Environmental Review Requiid:
DATE.OF COMPLETION: -
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
Discretionary Action Required: YES NO X TYPE
APPROVAL/RESO. NO. DATE
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval:__________________________________________________
LI Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES____ NO____
CA Coastal Commission Authority? YES X NO____
If California Coastal Commission Authority: Contact them at - 3111 Camino Del Rio North, Suite 200, San Diego CA 92108-1725; (619) 521-8036
L.4+r Determine status (Coastal Permit Required .or Exempt): E Crnj k - Coe)4cL I Cmr4'.
Coastal Permit Determination Form already completed? YES .-.NO____
If NO, complete Coastal Permit Determination Fo1mnbw.
Coastal Permit Determination Log #:
Follow-Up Actions:
Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum
Floor Plans).
Complete Coastal Permit Determination Log as needed.
(Z~ Item Incomplete - Needs your action
YES NO TYPE
11 fl fl Inclusionary Housing Fee required: YES NO
(Effective date of lnclusiânary Housing Ordinance - May 21, 1993.)
Data Entry Completed? YES NO - (AIPIDs. Activity Maintenance, enter CB#, toolbar, Screns. Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!)
' Site Plan:
E 1. Provide a fully dimensional site plan, drawn to scale. Show: North arrow,
property lines, easements, existing and proposed structures, streets, existing
street improvements, right-of-way width, dimensional setbacks and existing
topographical lines.
2. Provide legal description of property and assessor's parcel number.
X F-1
Zoning:
Setbacks:
Front: Required 1-5- Shown
-:
4.5
Interior Side: 'S Required 5' Shown 5'
Street Side: Required - Shown -
Rear: Required of Shown I C'
)' Accessory structure setbacks:
Front: Required - Shown -
Interior Side: Required 5' Shown 5'
Street Side: Required - Shown -
Rear: Required 10' Shown 10'
Structure separation: Required 10' Shown '
Lot Coverage: Required - 0 % Shown
Height: Required ''5 Shown
LI LI 5. Parking: Spaces Required 2 Shown •_____________
Guest Spaces Required Shown
' Addiiioa(Cmmentsflo Li 4LLS I fences over 4Y, k •k clIo eJ T 'yarc £-boc.k..
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER 0,1 DATE'1 i1
OR CAUFORNLA COASTAL COMMISSION
SAN DIEGO GOAffrAREA
3111 CAMIPIO DEL RIO NORTH. SUM 200
SAN DIEGO, CA 92100.1735
(610) 6214a59
NOTICE OF COASTAL DEVELOPMENT PERMIT WAIVER
DATE: April 2, 1999
TO: Gerald & Myrna Jones
FROM: Peter M. Douglas, Executive Director
SUBJECT: Waiver of Coastal Development Permit Requirement:
Waiver Os Minimis Number 6-99-042-W
Based on project plans and information submitted by the applicant(s) named below regarding
the development described below, the Executive Director of the Coastal Commission hereby
waives the requirement for a Coastal Development Permit, pursuant to Title 14, Section 13238
of the California O.fRegtian.
APFUCAN1 Gerald & Myrna Jones
LOCATION: 138 Sequoia Avenue, Carlsbad (San Diego County) (APN(s) 206411-06)
DESCRIPTION: Demolition of a one-story single family dwelling and construction of a 3,836 sq.ft., two-
story single family residence and 775 sq.ft. attached garage on a 5;401 sq.ft. lot -
RATIONALE: The proposed project is located in an established residential neighborhood consisting of
single-family residences similar to the proposed development. The development will not
block any public views and adequate parking will be provided. The proposed residence
Will not result in adverse visual impacts from Agua Hedionda Lagoon The proposed
project is consistent with the planning and zoning designations of the certified Ague
Hedionda Land Use Plan; thus, no adverse impacts to coastal resources are anticipated.
IMPORTANT: This waiver is not valid unless the site has been posted AND until the waiver
has been reported to the Coastal Commission. This waiver is proposed to be reported to the
Commission at the meeting of Wednesday, April 14, 1999, in Long Beach. If four
Commissioners object to this waiver, a coastal development permit will be required.
Persons wishing to object to or having questions regarding the issuance of a coastal permit
waiver for this project should contact the Commission office at the above address or phone
number prior to the.Conmiss..on meeting date.
Sincerely, By: BILL PONDER
PETER M. DOUGLAS Coastal Program a4
Executive Director
Supervisor
49W.11 TV,
OP-N;;\4_
1'l
)Xlfr ° iM) A'ki CçfO1O
-W• 6 /t'm NC-
RICHARD W. HARTLEY, PRES.
R.C.E. 20934; EXP. 9/30/2001
135 W. MISSION AVE., SUITE 200
ESCONDIDO, CA. 92025
4EIo
-AMPAPAviv
Hi1\: I
4
Scale: 38i________
date 2-8--00 for: Jerry and Myrna Note
project no. Jones
136 Sequoia
Carlsbad, CA 92008 drawinQ C
. .... ...... .. ... ....... ..... .. ...........
J~V r6 ot' J'rt, 000otA,
V.
AM ENGINEERS
V Consulting structural engineers
V 325W. 3rd Ave., Suite 2051 Escondido, CA. 92025
Phone (760)741-73061 Fax (760) 738-8364
STRUCTURAL CALCULATIONS
PROJECT NAME Jones Residence
PROJECT NO. 99001
CLIENT Roy R. Blackford Architect
This signature is to be a wet I DESIGNED
signature not a copy I
APPROVED : V BY A. M.
DATE SIGNED DATE: March 1999
* .1111701
AM ENGINEERS
- 325 W. 3rd Ave., Suite 205, Escondido, CA. 92025
Phone (760) 741-7306 Fax(760)738-9364
March 08, 1999
CRITERIA
(Roof Loading) (Floor Loading)
Tile Wt. 2.0 psf Li&IIT w/ 2.5 PS Plywood 1.5 psf Plywood 2.3 psf
Trusses 3.0 psf Joists 3.0 psf
Insulation 0.5 psf insulation 0.5 psf
Gyp. Brd. 2.5 psf Gyp Brd. 2.5 psf
Slope Adj. 1.0 psf
Misc. 1.5 psf Misc. 1.7 psf
3(7 DL= . 12 psf DL= .10 psf
LL= 16. psf LL= 40 psf
Exit LL= 100 psf
Seismic: Zone IV V=0.183W
Wind: Exp. TMB" P= 10.16 psf 0-15' high
Soils: Brg.=1500 psf
Concrete: f'c=2000 psf for footings and slab
Réinforc.: Fy60000 psf for #5 and grater
Fy40000 psf for #4 and smaller
Lumber: DF/L #1 for 2X rafters, 2x joists, beams and posts.
DF/L #2 . for 2x studs.
24F-V4 for simple span glue-laminated beams
24F-V8 for continuous glue-laminated beams
Steel: ASTM A500, grade B for tubular sections
ASTM A501, or ASTM A53, type E grade B for circular sections
ASTM A36 for wide flange sections and plates.
Weld: Welding should conform to AWS DI-1. All welding shall be done by electric arc process
using approved rods and performed by certified welders. All fabrication and welding shall be
performed in the shop of an approved fabricator. The approved fabricator must submit a
certificate of compliance in accordance with U.B.C. section 1701.7. All field welding requires
continuous special inspection and all shop welding requires periodic special inspection.
Code: U.B.C. 1994 edition
Al
AM ENGINEERS
Consulting Structural Engineers
(760) 741-7306
JOB
SHEET NO. OF
CALCULATED BY DATE
/=)i-ti)(74.5/f 2) 4Z7 4=i_
4L(295
ffaft(- 75
/4ViiiJ;: 2 //
*- 2*I(z ,5/?t2) 4-7
-FL( 44q5
J1oi- 2t/5
4I N. c In 5
2I7 4m
670
1ei 5/M
AM ENGINEERS
Consulting _Structural _Engineers
(760) 741-7306
JOB * llaal
SHEET NO. 3 1 OF
CALCULATED BY DATE
E1o0s. 3-01ST I25/61L)
L4,i(4 +440) i'-/, /5) *1 ,t1 6iF'/ frsls'flitw
p / N04u 71-72 fr <'q A2o
I 'F IT//p,co '550 4f /&'/c
TO ;'-c-" MAX, '5/4&i
)f-" T31/pf0 3,50 M k"o'c
-10 21 /14( 5fM'-'
..II.. 'I
I4 Ti1 I AT 1
To )e 4)
250 AT 4ye
-TO /4'-,'r14X fSAJ
"frtu %35-s4o) I
)I4U 57 i e/35t
DI-t(,fr 1950
rtIq- 45/3 k
(oi- 7oo '
D14Zt'44242'
frlol-(-u =
I'f
AM ENGINEERS
Consulting _Structural _Engineers
(760) 741-7306
JOB
SHEET NO. OF
CALCULATED BY DATE
I/4 4H
tloi*tt.= 3'o4
g Pt
1D)rU 119$5i
ripitt .7p7t# &c/i pc1 o,v4f
-3 1 l3'
2.ç 1'oMi q)
2Z23 I'j)I1 'S,' 3SJ2
1Q14(( /.32-4 l--z.
%I,. It
7;x)'e4iU
(6,d4 PIE OA)IX)
Altai- 4$(22-h
Awk I j( 7 ilz 1o4
ro)1(.7Z 4 Fe—I
A M ENGINEERS
Consulting Structural Engineers
JO
SHEET NO. OF
CALCULATED BY DATE
(760) 741-7306
L15.s /
Jc--t( 4oz(
L ..
.4
2' '1 '
''5 Ott(5X3/i. 145
fr1y.i..0 Pi6"~
Fe-i 4'
4- 'v+1fJI 4/2 f34J
'12-' I jttf2s(Zf 2) 1-k.Io I- '54rt t1
11:145 ø rp/Lc -2xWz x )5J2
fr1au 7ojq,,o4c, 3cii1/ fitqw
10( e 6O24 D141( 5,2)5 T-0-1 'I
- 1&2 -.4 tj
.,,,
AM ENGINEERS
Consulting _Structural _Engineers
(760) 741-7306
JOB
SHEET NO. OF-
CALCULATED BY DATE_____________________
I
tlD)kLt- 2az,'4 :::),,i'o'4
6 i'?
L]H1I io
Wg1w1=-4A9,e.24.512 =1041
p1-ft(.73
?lD'Lk4o c13-.
= LI. •
11D1 -tu6 Z -tiCs (64 -2) ti -4rI i-5' "25.5/z •
I "
F62 je.
AM ENGINEERS
Consulting _Structural _Engineers
(760) 741-7306
JOB
SHEET NO.12A OF
CALCULATED BY DATE
ThH-.
d lox
7PEL
it
III
I t. , I,
-.ILoi-
AcH io -. i;&
AM ENGINEERS
Consultinq Structural Enalneers
JOB Allowt
SHEET N0.17 OF
CALCULATED BY DATE
(760) 741-7306
-t1M.dsi.
446 X
WALl
r1ooj DI :c ::iz,AIIIA
I4L1 Of 1(xfoXZ
11 £33) wt.*/p,-) I19J 1(
fWF
Flift. 1014$ l45O 2)4
Vo.1g,4/ 3 q7t1 -.
_=Paifl.h-
W/o.i(k12 ác4
/oz//1 cit
¶rr6
-) Fv
AT 4
çI4//,r rep R4' IPAfs
J7!tQ/. 41 ri'J
34'øi ?f (4/lQ)
pAJ1-
AT W
A M ENGINEERS
Consulting Structural Engineers
(760) 741-7306
JOB -q'oo I
SHEET NO. OF
CALCULATED BY DATE
(2iri)
?tFLI2i'f7
101
F1ac ol
4u /(x('X2.*ixoy4
L-viL 11 ()
IROOF .91 1491-
509 lo
701)4.
=3255 411111
'kJ
- L4I.3(_fr
F/- -_ P 53 - /4g4-
.w11 Ic'Ii-x /o/ -- 5.5/2 ) 77
I
-p
-
-
AM ENGINEERS
Consulting Structural Engineers
JOB
SHEET NO. OF__________________
CALCULATED BY DATE
(760) 741-7306
I
AWS )M)21
107
CoV'
1?viai/ I3.!Z; (2sA-fì ioq +
1J4li42-7 #/p.
u1,,h7—q4/--Po 55
wI - /13tV /1' - 5Er3e1L
fr ./3.I.ic34-/3 Is.44 'fi
F 5
4icq
up/i/I 346 - 4,5a - 4o)' 5.5//2 M5r4 t/t,L
I3J3!/3? 145•5
F51
VwaiI& L
//1/c-'3'o3z.-4- -32 1<3gI5 oLc M.'bi-fl ki/ejy:
WJ4.5//J
aJJI4cs>Ij. 5/z2-) 5;c
VfrfgJ/ cg /,/
3-4 LSD--Igo 10-4q13 PT7 %If 4s
DATE CALCULATED BY
W'4( 43z53. ó1/z *)
Lz--i-i --'
IA1/ 142 #/p
rm: W43743x24//7 :::5/
/,i, •
L-IQ'
'Viiai( 15///
bpljp,L - ,o -/'! -' o'r,ii, ai a4/ 7.43i.
a
ki4.355 /2.7/q7 -/2/..7'/
LI/rn;! 431a--4o-1k1
AM ENGINEERS
Consulting _Structural _Engineers
(760) 741-7306
JOB
SHEET NO. J1 OF
Al
UPI/f/44)E -73z-27,-Z/
U'dI2O/.. 10
AM ENGINEERS
Consulting Structural Engineers
(760) 741-7306
JOB
SHEET NO. OF
CALCULATED BY DATE
V'4*
U1111i/-- 2:Vfr /520 .-;- 43$ =-9-714 2.,4 You
45 j,I#I0
27JI 4.
DRfrG- O1 jfri iJ #/o
Z~ae ..............4........ frT(o
f: 5 4112 I YtT) /4$
jJgf/ 7-7i7q,-5Ao--252, 4o71 I+DM /4;L
44 I i1/3.5 ),5:41'
Sdj6.459(/-/z.- 53a. (5d ii4) 4127j:
L--4-i-1/ .
7]
'•X 7- 3Z' - 'lb +A 14b lOA 44e
AM ENGINEERS
Consulting Structural Engineers
JOB
SHEET NO.14 OF
CALCULATED BY DATE
(760) 741-7306
IV-5
¶2 /2 + 757: (S.
VJ/
opLi/ T2z" -*bo 3_$- •2; 85
,'t1F4744 4,735 -Lao =.74.25 • 015A ticfr
ji
k465/3
w132O a/2* 14 Z c,)E 35/2-1- ()c/.: (5.v.7)+ 2756.1 *b) =,070.
U,Jf'35I-"V/
34o
?\YlJ; 2 3 'r
L-- if/
ee-
u,rn/I..r 15,4 '4
JOB 4p /92OJ 1—aJc4S
AM ENGINEERS SHEET NO. _L5_ OF
Consulting _Structural _Engineers CALCULATED BY DATE
(760)741-7306
/4o,it-r 4€ OIi rJ
& 1 - I
I,
III
-
W)t-xz ALL p1f?l8'R
•
iil
T
-
____
I
-ti.,.'755 15'f'
.4$/h4ltEtv/ 5/Iø -ri'V Bows
4t;34'O/t ..,ip.801r 14E05WDT
Moie- - 7/M,J !"frJTo T,1 ,i4ILEi-
34i'/z
4c1 1D
W14/2
I •
I I
I •
I! I •
I I I
I I -
ITY
I F44
j 44iØX ØoL1) / ii"
-'-I
9l'
PROGRAM : General Frame Analysis v2.05 PAGE NO. 16 A N Engineers TIME : Wed May 5 09:29:22 1999 JOB : Jones Residence JOB NO. : 57 RUN : 99001
NODAL INFORMATION NODE NODAL COORDINATESi SUPPORT CONDITIONS NO X Y CODE PX STIFF PY STIFF M STIFF
Units : Ft Ft K /In K /In K -In /Deg
1 0.000 0.000 H
2 0.000 11.000
3 12.000 11.000
4 12.000 0.000 H
ELEMENT INFORMATION ELEM NE PE ELEM BETA PROP ELEM NE PE NO NODE NODE LENGTH ANGLE TYPE TYPE HINGE HINGE
Units : Ft Deg
1 1 2 11.000 90.00 1 BEAM
2 2 3 12.000 0.00 1 BEAM
3 4 3 11.000 90.00 1 BEAM
PROPERTY INFORMATION
PROP SECTION
NO NAME MODULUS AREA I DIST
Units : K /In 2 In2 In4 Ft
1 w 16x26 2.9e+004 7.68 301
ELEMENT LOAD INFORMATION
REC LOAD LOAD LOAD DIST
NO CASE TYPE SYS SPEC DIST PX PY M
Units : Ft K /Ft K /Ft Ft-K /Ft
Description : dl
Element List : 2
1 1 UNIF GLO DIST B 0.00 0.00 -0.37 0.00
E 12.00 0.00 -0.37 0.00
Description : 11
Element List : 2
2 2 UNIF GLO DIST •B 0.00 0.00 -0.53 0.00
E 12.00 0.00 -0.53 0.00
$ I
PROGRAM : General Frame Analysis v2.05 PAGE NO. 17 A M Engineers TIME : Wed May 5 09:29:25 1999. JOB : Jones Residence . JOB NO. : 57 RUN : 99001
NODAL LOAD INFORMATION
REC LOAD LOAD PX PY M NO CASE TYPE DX DY BETA
Units •: K K Ft-K
Ft Ft Deg
Description : Seismic . .
Node List : 2
1 3 FORCE 8.71 0.00 0.00
-----------------------------------
PROGRAM : General Frame Analysis v2.05 PAGE NO. 18 A N Engineers TIME : Wed May 5 09:29:25 1999 JOB : Jones Residence JOB NO. : 57 RUN : 99001
NODAL DISPLACEMENTS NODE LOAD
NO CASE DX DY ROTATION
Units : In In Deg
1 1 0.0000 0.0000 0.0047
2 0.0000 0.0000 0.0068 3 0.0000 0.0000 -0.3441
2 1 0.0001 -0.0013 -0.0096
2 0.0001 -0.0019 -0.0137
3 0.6012 0.0047 -0.0947
3 1 -0.0001 -0.0013 0.0096
2 -0.0001 -0.0019 0.0137
3 0.5984 -0.0047 -0.0939
4 1 0.0000 0.0000 -0.0047
2 0.0000 0.0000 -0.0068
3 0.0000 0.0000 -0.3426
ELEMENT FORCES
ELEM LOAD NODE
NO CASE NO AXIAL SHEAR MOMENT
Units: K K K-Ft
1 1 -2.2200 -0.2502 0.0000
2 -2.2200 -0.2502 -2.7520
2 1 -3.1800 -0.3584 0.0000
2 -3.1800 -0.3584 -3.9421
3 1 7.9842 4.3611 0.0000
2 7.9842 4.3611 47.9718
2 1 2 -0.2502 2.2200 -2.7520 3 -0.2502 -2.2200 -2.7520
2 2 -0.3584 3.1800 -3.9421
3 -0.3584 -3.1800 -3.9421
3 2 -4.3489 -7.9842 47.9718
3 -4.3489 -7.9842 -47.8382
3 1 4 -2.2200 0.2502 0.0000 3 -2.2200 0.2502 2.7520
PROGRAM : General Frame Analysis v2.05 PAGE NO. 19 A N Engineers TIME : Wed May 5 09:29:25 1999 JOB : Jones Residence JOB NO. : 57 RUN : 99001
ELEMENT FORCES
ELEM LOAD NODE
NO CASE NO AXIAL SHEAR MOMENT
2 4 -3.1800 0.3584 0.0000
3 -3.1800 0.3584 3.9421
3 4 -7.9842 4.3489 0.0000
3 -7.9842 4.3489 47.8382
REACTIONS
NODE LOAD
NO CASE PX PY MOMENT
Units: K K K-Ft -
1 1 0.2502
2 0.3584
3 -4.3611
4 1 -0.2502
2 -0.3584
3 -4.3489
2.2200 0.0000
3.1800 - 0.0000
-7.9842 0.0000
2.2200 0.0000
3.1800 0.0000
7.9842 0.0000
S
PROGRAM : General Frame Analysis v2.05 PAGE NO. 20 A M Engineers TIME : Wed May 5 09:29:26 1999 JOB : Jones Residence JOB NO. : 57 RUN : 99001
NODAL DISPLACEMENTS
NODE LOAD
NO COMB DX DY ROTATION
Units : In In Deg
LOAD COMBINATIONS:
COMB 1 : 1.00 X CASE 1
+ 1.00 XCASE 2
COMB 2 : 0.75 X CASE 1
+ 0.75 X CASE 3
1 1 0.0000 0.0000 0.0115 2 0.0000 0.0000 -0.2545
2 1 0.0002 -0.0032 -0.0233
2 0.4510 0.0026 -0.0782
3 1 -0.0002 -0.0032 0.0233
2 0.4487 -0.0045 -0.0633
4 1 0.0000 0.0000 -0.0115
2 0.0000 0.0000 -0.2605
ELEMENT REPORTS
ELEM LOAD NODE SIGN CONVENTION : BEAN DESIGNERS
NO COMB NO AXIAL SHEAR MOMENT MAX MOM/DEFL DIST
Units : K K K -Ft K -Ft /In Ft
LOAD COMBINATIONS:
COMB 1 : 1.00 X CASE 1
+ 1.00 X CASE 2
COMB 2 : 0.75 X CASE I
+ 0.75 X CASE 3
1 1 -5.4000 -0.6086 0.0000
2 -5.4000 -0.6086 -6.6941 0.0103 6.35
2 1 4.3231 3.0832 0.0000
2 4.3231 3.0832 33.9148 -0.0521 6.35
PROGRAM : General Frame Analysis v2.05 PAGE NO. 21 A M Engineers TIME : Wed May 5 09:29:26 1999 JOB : Jones Residence JOB NO. : 57 RUN : 99001
----------------
ELEMENT REPORTS ELEM LOAD NODE SIGN CONVENTION : BEAM DESIGNERS NO COMB NO AXIAL SHEAR MOMENT MAX MOM/DEFL DIST
2 1 2 -0.6086 5.4000 -6.6941 9.5059 6.00 3 -0.6086 -5.4000 -6.6941 -0.0243 6.00
2 2 -3.4493 -4.3231 33.9148
3 -3.4493 -7.6531 -37.9427 -0.0212 2.94
3 1 4 -5.4000 0.6086 0.0000
3 -5.4000 0.6086 6.6941 -0.0103 6.35
2 4 -7.6531 3.4493 0.0000
3 -7.6531 3.4493 37.9427 -0.0583 6.35
REACTIONS NODE LOAD
NO COMB PX PY MOMENT
Units: K K K-Ft
LOAD COMBINATIONS:
COMB 1 : 1.00X CASE 1
+ 1.00 X CASE 2
COMB 2 : 0 • 75 X CASE 1
+ 0.75 X CASE 3
1 1 0.6086 5 000 0.0000
2 -3.0832 -4.3231 0.0000
4 1 -0.6086 5.4000 0.0000 2 -3.4493 7.6531 0.0000
SHEAR WALL SCHEDULE
Wall Material Nailing p p1. shear Sill p1. shear Anchor bolts at Remarks tAllow.
rtroansfer transfer foundations I
1/2" struc. 1 ply both lOd @ 4" 0/c edges, A35 @ 6" o/c, 3x top 16d @ 1.5 o/c 5/8"x12" A. bolts 3x studs @ panel ends, 3x blocking
I sides 12" 0/c field ,I. over 2x stagg., 3x sill p1. 12" 0/c at panel edges 1020 #/ft
1/2" struc. 1 ply one lOd @ 3" o/c edges, A35 @ 8" o/c, 3x top 16d @ 3" o/c, 3x 5/8"x12" A. bolts 3x studs @ panel ends, 3x blocking
2 side 12" oc field ,l. over 2x sill p1. 24" o/c at panel edges 667 #/ft
1/2" struc. 1 ply one lOd @ 4" o/c edges, A35 @ 10" o/c 16d @ 3" o/c 5/8"x12" A. bolts
3 side 12" oc field 24" o/c 510 #/ft
3/8" CD-X ply one 8d @ 6" o/c edges, 12" A35 @ 16" 0/c 16d @ 6" 0/c 5/8"x12" A. bolts
4 side oc field 32" 0/c 260 #Ift
3/8" CD-X ply one 8d @ 4" o/c edges, 12" A35 @ 16" o/c 16d @ 4" o/c 5/8"x12" A. bolts
5 side oc field 24" o/c 380 #/ft
3/8" CD-X ply one 8d @ 3" o/c edges, 12" A35 @ 12" o/c 16d @ 3" o/c 5/8"x12" A. bolts
6 side oc field 24" o/c 490 #/ft
3/8" CD-X ply both 8d (l 4" o/c edges, 12" MS @ 6" o/c, 3x top 16d @ 2" 0/c 5/8"x12" A. bolts 3x studs @ panel ends, 3x blocking
7 sides oc field ,1. over 2x stagg., 3x sill p1. 16" o/c at panel edges 760 #/ft
3/8" CD-X ply both 8d @ 3" 0/c edges, 12" A35 @ 6" o/c, 3x top 16d @ 1.5 0/c 5/8"x12" A. bolts 3x studs @ panel ends, 3x blocking
8 sides oc field g. over 2x stagg., 3x sill p1. 16" 0/c at panel edges 980 #/ft
1/2" Gyp. Brd., one 5d cooler nails @ 7" A35 @ 32" o/c 16d @ 12" o/c 5/8"x12" A. bolts
9 side 0/c (blocked) 72" 0/c
1/2" Gyp. Brd., one 5d cooler nails @ 4" A35 @32" 0/c 16d@ 10" 0/c 5/8"x12" A. bolts
10 side 0/c (blocked) 48" o/c
1/2" Gyp. Brd., both 5d cooler nails @ 4" A35 @ 16" 0/c 16d @ .10" o/c 5/8"x12" A. bolts
11 sides 0/c (blocked) 32" o/c
1/2" Gyp. Brd., both 5d cooler nails @ 7" '35 ® 16" o/c 16d @ 6" o/c 5/8"x12" A. bolts
12 sides 0/c (blocked) 32" 0/c
5/8' Gyp Brd., both 6d cooler nails @4" MS @32" 0/c 16d@ 8" o/c 5/8"x12" A. bolts
13 sides 0/c (blocked) 32" 0/c
718" stucco WI expan. No. 11 Ga. 1.5" long, MS @ 24" o/c 16d @ 10" o/c 5/8"x12" A. bolts
14 metal or woven wire lath @ 7116'head nail,16 Ga. 8" 0/c 180 #/ft port. cern. plast. staple, 718 leg @ 6" 0/c
r
Notes: 1. all supports for gyp. brd. to be nailed with cooler nails.
All plywood panel edges to be blocked and be nailed at 12" 0/c.
At shear walls with plywood on both sides. Both veut. & horiz
Joints on opposite sides of wall shall be staggered.
2-Anchor bolts per wall minimum
Minimum anchor bolt spacing at 77 0/c. for exterior walls.
Abbreviations:
ply plywood Ga. gauge
p1. plate brd. board
. anchor
.dagg. staggered
wp gypsum
port. Portland
f05T t040 o,J J1/,oV5 rre-
4!LI2-5xJ00 7
A M ENGINEERS
Consulting _Structural _Engineers
(760) 741-7306
JOB
SHEET NO'LS OF
CALCULATED BY DATE
CO,JUitJgW5 Pro- D5I61-)
Il-i-
1-1ooi 01-ia '35-t4o)f/2_
VAU 9(.
I,
..,. 54/ t5 I'o
AL Co,.rt,'.JQ rro
I,
/5 MOt, / #rn 8E1
,40r HE) AO
fr/ltl rap ifof.
I1A"/ F05T 1a40 ot-)
Codft1'J0a0$ r-rc ,4/oT
-iZ;' ExO 'z'
ji LI/ TO 13.?
/ (, / I, 'I 3x3-c'xI 41"
40i Ffr.J154t0 C-AP 1
fri -'-'•
3l1çI -
F':::/pjar,o '
=1iFJ-
,4-k,,J1& F
247?.)
432!
[fjfl AM ENGINEERS
Consulting _Structural _Engineers
(760) 741-7306
JOB
SHEET NO. OF_____________________
CALCULATED BY DATE_____________________
FEcT OF *0e41 aJ E3c,si wr# RETA!'JI v,ti Pot-4 fl
Geotechnical *Geologic * Environmental
5741 Palmer Way • Carlsbad, California 92008 • (760) 438-3155 • FAX (760) 931-0915
May 3, 1999
W.O. 2504-A-SC
Jerry and Myrna Jones
do Roy R. Blackford, Architecture and Land Planning
2942 Harding Street, Suite E
Carlsbad, California 92009
Subject: Liquefaction and Dynamic Settlement Potential, 136 Sequoia Avenue,
Carlsbad, California
References: 'Preliminary Geotechnical Evaluation, 136 Sequoia Avenue, Carlsbad, San Diego County,
California," W.O. 2504-A-SC, dated August 18, 1998, by GeoSoils, Inc.
Gentlemen,
1n accordance with a request from Mr. Roy Blackford, and to comply with the City of
Carlsbad plan check comments, GeoSoils, Inc. (GSI) has evaluated the potential for
liquefaction and associated dynamic settlement to affect the site.
Seismically-induced liquefaction is a phenomenon in which cyclic stresses, produced, by
earthquake-induced ground motion, create excess pore pressures in soils. The soils may
thereby acquire a high degree of mobility, and lead to lateral movement, sliding, sand
boils, consolidation and settlement of loose sediments, and other damaging deformations.
This phenomenon occurs only below the water table; but after liquefaction has developed,
it can propagate upward into overlying, non-saturated soil as excess pore water dissipates.
Typically, liquefaction has a relatively low potential at depths greater than 45 feet and is
virtually unknown below a depth of 60 feet:
Liquefaction susceptibility is related to numerous factors and the following conditions
should be present for liquefaction to occur: 1) sediments must be relatively young in age
and not.have developed a large amount of cementation: 2) sediments generally consist
of medium to fine grained relatively cohesionless sands; 3) the sediments must have low
relative density: 4) free groundwater must be present in the sediment; and 5) the site must
experience a seismic event of a sufficient duration and magnitude, to induce straining of
soil particles.
99 /115 P
Inasmuch as a majority of these conditions do not exist onsite and the entire site is
underlain by relatively dense terrace deposits, àUr evaluation indicates that the potential
for liquefaction and associated adverse effects (dynamic settlement) within the site is very
low.
Since our study is based upon the site materials and conditions observed, selective
laboratory testing and engineering analysis, the conclusion and recommendations are
professional opinions. These opinions have been derived in accordance with current
standards of practice and no warranty is expressed or implied. Standards of practice are
subject to change with time. GSI assumes no responsibility for work, testing or
recommendations performed or provided by others.
The opportunity to be of service is greatly appreciated. If you have any questions, please
do not hesitate to call our office.
Respectfully submitted,
GeoSoils, Inc.
,çtD EO 'L; No.i934 \ R.
Robert G. Crisman
Engineering Geologist, C
RGC/ARKIkI
Distribution: (4) Addressee
- Albert R:Kleist---- - -
Geotechnical Engineer, E
No. 476
Exp. 06-30-01
Jerry and Myrna Jones W.O. 2504-A-SC
136 Sequoia Avenue May 3, 1999
FiIe:e:\wpl\2500\2504a.Iad Page 2
Inc.
0 .
S9
Geotechnical • Geologic. Environmental
5741 Palmer Way • Carlsbad, California 92008 • (760) 438-3155 • FAX (760) 931-0915
April 1, 1999
W.O. 2504-A-SC
Jerry and Myrna Jones
do Roy A. Blackford, Architecture and Land Planning
2942 Harding Street, Suite E
Carlsbad, California 92009
Subject:
References
Gentlemen,
Addendum to the Plan Review, Side Yard Drainage, 136 Sequoia Avenue,
Carlsbad, California
"Plan Review, Residential Development at 136 Sequoia Avenue, Carlsbad, California,"
W.O. 2504-A-SC, dated February 10, 1999, by GeoSoils, Inc.
Diego
3. "Architectural Plans for Jerry and Myrna Jones, 136 Sequoia, Carlsbad, CA. 92009," NJ Job# 9808, dated December 11, 1998, by Roy E. Blackford, Architecture and Land
Planning.
"Preliminary Geotechnical Evaluation, 136 Sequoia Avenue, Carlsbad, San
County, California," W.O. 2504-A-SC, dated August 18, 1998, by GeoSoils, Inc.
In accordance with your request, GeoSoils, Inc. (GSI) has reviewed the referenced reports
and have prepared this addendum to our plan review dated February 10, 1999, regarding
a side yard setback and location of a drainage swale. Based on our review, the minimum
distance from a given structure to the flow line of side yard drainage may be reduced from
5 feet, per City Standard GS-1 5, to a minimum of 3 feet. Due to the decreased setback
from structure to drainage swale, footings for the structure should maintain a minimum
embedment equivalent to 12 inches below the flow line elevation of the adjacent drainage
swale. Trenching for any utilities adjacent to a footing should remain above a 1:1
projection downward from the outside bottom edge of the footing. All trenched should be
compacted to a minimum 90 percent relative compaction. The use of roof gutters and
downspouts should also be considered.
Since our study is based upon our review of the referenced plans and our referenced
report, the conclusion and recommendations are professional opinions. These opinions
have been derived in accordance with current standards of practice and no warranty is
expressed or implied. Standards of practice are subject to change with time. GeoSoils,
Inc. assumes no responsibility or liability for work, testing or recommendations performed
or provided by others.
ct3Tt4
No.
Exp. O8-3
CAU
The opportunity to be of service is greatly appreciated. If you have any questions
concerning this report or if we may be of further assistance, please do not hesitate to
contact any of the undersigned.
Respectfully submitted,
GeoSoils, Inc.
G.
Robert G. Crisman I fk 'io. i ,1Iert A. Kleist
Project Geologist, CE IG Engineer, 1W e technical G
RGC/ARK/mo
J'zs iL1 -, OF ,
Distribution: (4) Addresse--'
Jerry and Myrna Jones W.O. 2504-A-SC
136 Sequoia Avenue April 1, 1999
File:e:\wp7\2500\2504a.att Page 2
GeoSoits, Inc.
S9
Geotechnical • Geologic • Environmental
5741 Palmer Way • Carlsbad, California 92008 • (760) 438-3155 • FAX (760) 931-0915
February 10, 1999
W.O.2504-A-SC
Jerry and Myrna Jones
do Roy R. Blackford, Architecture and Land Planning
2942 Harding Street, Suite E
Carlsbad, California 92009
Subject: Plan Review, Residential Development at 136 Sequoia Avenue, Carlsbad,
California
References: 1. "Preliminary Geotechnical Evaluation, 136 Sequoia Avehue, Carlsbad, San Diego
County, California," W.O. 2504-A-SC, dated August 18, 1998, by GeoSoils, Inc.
2. "Architectural Plans for Jerry and Myrna Jones, 136 Sequoia, Carlsbad, CA. 92009,"
Job# 9808, dated December 11, 1998, by Roy R. Blackford, Architecture and Land
Planning.
Gentlemen,
In accordance with a request from Mr. Roy Blackford, and to comply with the City of
Carlsbad plan check comments, GeoSoils, Inc. (GSI) has performed a review of the
Architectural plans (Sheets 1, 2,4, 5 and 9) prepared by Roy R. Blackford Architecture and
Land Planning, for the proposed subject project.
The plans reviewed appear to be in general conformance with the recommendations
provided by this office and presented in GSI (1998), with the following comments and/or
additional recommendations.
The referenced report, prepared by GSI, should be shown on the referenced
plans.
Since our study is based1upon the site materials and conditions observed, selective
laboratory testing and engineering analysis, the conclusion and recommendations are
professional opinions. These opinions have been derived in accordance with current
standards of practice and no warranty is expressed or implied. Standards of practice are
subject to change with time. GSI assumes no responsibility for work, testing or
recommendations performed or provided by others.
The opportunity to be of service is greatly appreciated. If you have any questions, please
do not hesitate to call our office.
Respectfully submitted,
GeoSoils, Inc.
Robert G. Crisman A
Engineering Geologist, CE
RGC/ARK/mo
Distribution: (4) Addressee
Albert R. Kleist
Geotechnical Engi
-.,
ç;-cP
r476
No. 476
Exp. 06-30-01-0i' )
OF
Jerry and Myrna Jones W.O. 2504-A-SC
136 Sequoia Avenue . February 10, 1999
Fi1e:e:\wp72500\2504a.prr Page 2
GeoSOils, Inc.
City of Carlsbad
CERTIFICATE OF COMPLIANCE
PAYMENT OF SCHOOL FEES OR OTHER MITIGATION
This form must be completed by the City, the applicant, and the appropriate school districts and returned to the City
prior to issuing a building permit. The City will not issue any building permit without a completed school fee form.
Project Name: JONES RESIDENCE
Building Permit
Plan Check Number: CB991456
Project Address: 136 SEQUOIA AVENUE
A.P.N.: 206-01106
Project Applicant M/M JONES
(Owner(s) Name(s))
DEMO EXISTING 725 SF DWELLING Project Description: BUILD NEW 3,836 SF DWELLING
Building Type: WOOD FRAME RESIDENTIAL
Residential Number of New Dwelling Units DEMO ONE DWELLINGBUILD NEW ONE DWELLING
Square Feet of Living Area in New Dwelling DEMO 725 SF
BUILD NEW 3,836 SF
Second Dwelling Unit: Square Feet of Living Area in SDU
Res. Additions: Net Square Feet New Area
Comerc./ Ind.: Square Feet Floor Area /
City Certification of
Applicant's information:
8a&trT School District
Pine Ave. XXX
Carlsbad CA 92009 (729-9291
Union School District
iRanch Santa Fe Rd
San Marcos Unified School District
215 Mata Way
San Marcos, CA 92069 (736-2200)
San Dieguito Union High School District
710 Encinitas Blvd.
Certification of Applicant /Owners. The person executing this declaration ("Owner") certifies under penalty of perjury that (1) the
information provided above is correct and true to the best of the Owner's knowledge, and that the Owner will file an amended
certification of payment and pay the additional fee if Owner requests an increase in the number of dwelling units or square
footage after the building permit is issued or if the initial determination of units or square footage is found to be incorrect, and
that (2) the Owner is the owner/ developer of the above described project(s), or that the person executing this declaration is
authorized to sign on behalf of the Owner.
Signature: Date:
2075 Las Palmas Dr. • Carlsbad, CA 92009-1576 • (760) 438-1161 • FAX (760) 438-0894
Revised 3-18-99
'IIE 11:00 CITY OF CIRLSBID OC'11 DE F NO 43084 P. 03
I -
1 •
)RP NrcAE T-.t• T!-F C.
. r
or ownr has atist€1 tn (thiiqttOi Cr
t q 'ri -s -1 -n naqe 1 ras pEtIC ao amo'nk
'1: tur IAt hy thf Scioo L) t t I h4 Gry 'T
iILBlair
Assist Supt Crlsbid Unified School District
8USWSSIVic€ 801 Pine Avenue
Carlsbad, California 92008
L 6/4/9 9