HomeMy WebLinkAbout2231 RUTHERFORD RD; 110; CBC2020-0247; PermitBuilding Permit Finaled Commercial Permit Print Date: 11/18/2020 Job Address: CARLSBAD, CA 92008-8820 {city of Carlsbad Permit No: CBC2020-0247 Status: Closed -Finaled Permit Type: 2231 RUTHERFORD RD, # 110, BLDG-Commercial Work Class: Tenant Improvement Parcel#: Valuation: Occupancy Group: #of Dwelling Units: 2120701900 $581,037.00 Track#: Lot#: Project#: Plan#: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Project Title: Description: IMPLUS: 12,106 SF T.I. (OFFICE TO OFFICE)// 898 SF DECK FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) Property Owner: BECKMAN CARLSBAD I LLC 2231 RUTHERFORD RD CARLSBAD, CA ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL PLUMBING BLDG COMMERCIAL NEW/ADDITION/REMODEL SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-COMMERCIAL Total Fees: $4,712.79 Total Payments To Date: $4,712.79 Applied: Issued: Finaled Close Out: Inspector: Final Inspection: Contractor: 06/25/2020 08/21/2020 PBurn 11/18/2020 SP WHITE CONSTRUCTION INC 2524 GATEWAY RD CARLSBAD, CA 92009-1742 (760) 931-1130 Balance Due: AMOUNT $2,283.00 $1,598.10 $242.00 $175.00 $104.00 $124.00 $24.00 $162.69 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov r 'I r. C_ Cicyof Carlsbad COMMERCIAL BUILDING PERMIT APPLICATION B-2 PC Deposit ---~--~-- Date l, IQ Jla-o~ r • JobAddress 2-1-ol Rut\.flerfurd 12d. Suite: _lwl"-{_,_\_APN:2.12, . 070 . 09. Do CT/Project #: _________________ Lot#: 26 / Fire Sprinklers: ~S O NO Air Conditioning: ~S O NO Electrical Panel Upgrade: (i){Es O NO BRIEF DESCRIPTION OF WORK: Addition/New: _____ .Living SF, ___ Deck SF. 2.'.M:, Patio SF, ____ Garage SF Is this to create an Accessory Dwelling Unit? 0 YON New Fireplace? 0 YON, if yes how many? ~odel: l 2. I 06 SF of affected area ls the area a conversion or change of use ?OY r 0 Pool/Spa: ____ SF Additional Gas or Electrical Features? ------------- □solar: ___ KW, __ Modules, Mounted:ORoof OGround, Tilt:O YO N, RMA: 0 YON, Battery:OY ON, Panel Upgrade: Ov ON D Reroof: ---------------------------------- □ Plumbing/Mechanical/Electrical Only: ________________________ _ D Other: ________________________________ _ APPLICANT (PRIMARY CONTACT) PROPERTY OWNER Name: ~::iqe D,:;,~:e,j, Name: lNilliarn 2ei:l/2ooon, '&l½roao(corl'>l?ia4 1, L.L(. Address:3csJ Lov\,1;;;;;:;:; fe. Qv 5',Aii" tot. Address: EiOS /ifYJca:::, Sc:;;,c:¼c· C: Qt:-7 ,., \:f 1cc, I • City: So\C<I/\"' 0ettllr) State: Cl4-Zip: C/z.o-i";) City: 5ol0V1A Px:&Ch State: Cl4--Zip: "12 o:76 Phone: !3G B · 9?-".2. -C, ?,f, :;2., Phone: ~B ... -c...SuP>""-'•-"1."'c,"-'-i_,_· _,__J 7...,__7L..>=4>,.__ _______ _ Email: )?ropjce IQe c lA..,..-c,p-c (Y0- DESIGN PROFESSIONAL Name:0(!:.,J2t:.) fu, :b, ~ C-i~ Address: 1 c;;;; &k I & ;;;;;;;s; :1t ;_::;;; City: Sa~ D~O State: C:14 Zip: q-zo1 G. Phone: (4 lq • ~.L/1 • 3'F:xY) Email: P,cean e p.,,.\oe,ijV)~cP· CJ'!IY) Architect State License: ___________ _ Email: \Nvja e IOeUAQrDt,>. < D!O' CONTRACTOR BUSINESS Name: :lrAui.., S\(la\V) \Alki; If Y}t61:V\...\L+-ic,n Address: ZS2'::/ Mg.J.e1, v;.,, i2,c) I City: Cc,. I'" I ~po, ,::\. State: C 14 Zip: q-,.oc Cf Phone: tu-0 -c, <> I · ll ?,O )< 11)'.2 ' Email: 1" t:£1\1 i:> e W½; ie µ::<')SfvULb D~I V\ '-. c.ovY\ State License: IJ4";J,)/,'3 Bus. License: / :2.0'.2.? Bb (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov B-1 Paae 1 of 2 Rev. 03/20 ( OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury one of the following declarations: 01 have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the labor Code, for the performance of the work which this permit is issued. D ! have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name: ______________________ _ Policy No. ______________ Expiration Date: _________ _ D Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. CONTRACTOR SIGNATURE: __________________ □AGENT DATE: _____ _ ( OPTION B ): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: DI, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). ~ner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). DI am exempt under Section ________ Business and Professions Code for this reason: l. I personally plan to provide the major labor and materials for construction of the proposed property improvement. QvES Q NO 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number): 5. I will provide some of the w~ut 1Jve contracted (hired) the following persons to provide the work indicated (include name/ address/ phone/ type of work): owNER sIGNATURE: fl/ d « k 11:11 ,w~•"', '/iirt~GENT DATE: a(, 4 ( '-0 CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: _____________________ _ Lender's Address: _____________________ _ ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: ls the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25S34 of the Presley-Tanner Hazardous Substance Account Act? Yes / No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Yes/ No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes/ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES ANO THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. ! hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the worl< is commenced for a penod of 180 ~ 105.S. APPLICANTSIGNATURE:o/~~ I (tMJ;J4tqq Ktii1.6v1Z_ DATE: ft4t4,/~ 1635 Faraday Ave Carlsbad, CA 92008 8-1 Ph: 760-602-2719 Fax: 760-602-8558 Page 2 of 2 I Email: Building@carlsbadca.gov Rev. 03/20 PERMIT INSPECTION HISTORY for (CBC2020-0247) Permit Type: BLDG-Commercial Work Class: Tenant Improvement Status: Scheduled Date Closed -Finaled Actual Inspection Type Start Date BLDG-Electrical Final Wednesday, November 18, 2020 Application Date: 06/25/2020 Owner: BECKMAN CARLSBAD I LLC Issue Date: 08/21/2020 Subdivision: CARLSBAD TCT#81-10 UNIT#02A Expiration Date: 04/06/2021 IVR Number: 27071 Address: 2231 RUTHERFORD RD, # 110 CARLSBAD, CA 92008-8820 Inspection No. Inspection Primary Inspector Reinspection Inspection Status November 18, 2020: 1. Land development and engineering Chris Classen verified and approved, final Public Works/engineering department approvals and released hold on computer tracking system. 2. Final building inspection walk-through for: structural, plumbing, electrical, mechanical scope of work-approved per engineer and architects-plans details and specifications. 3. Final recycle and energy reports verified and filed in city records. Yes Page 4 of 4 PERMIT INSPECTION HISTORY for (CBC2020-0247) Permit Type: BLDG-Commercial Work Class: Tenant Improvement Status: Closed • Finaled Application Date: 06/25/2020 Owner: BECKMAN CARLSBAD I LLC Issue Date: 08/21/2020 Subdivision: CARLSBAD TCT#81-10 UNIT#02A Expiration Date: 04/06/2021 Address: 2231 RUTHERFORD RD, # 110 CARLSBAD, CA 92008-8820 IVR Number: 27071 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Primary Inspector Reinspection Inspection Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final Wednesday, November 18, 2020 Status COMMENTS November 17, 2020: 1. Building final inspection not completed. 2. Chris Glasson with land development engineering department needs to provide site inspection prior to building and safety final inspection walk-through. 3. Dave/site superintendent informed land development engineering needs to do a final walk-through inspection prior to building inspection final walk-through. Contractor/superintendent will reschedule final inspection. November 18, 2020: 1. Land development and engineering Chris Classen verified and approved, final Public Works/engineering department approvals and released hold on computer tracking system. 2. Final building inspection walk-through for: structural, plumbing, electrical, mechanical scope of work -approved per engineer and architects-plans details and specifications. 3. Final recycle and energy reports verified and filed in city records. November 18, 2020: 1. Land development and engineering Chris Classen verified and approved, final Public Works/engineering department approvals and released hold on computer tracking system. 2. Final building inspection walk-through for: structural, plumbing, electrical, mechanical scope of work -approved per engineer and architects-plans details and specifications. 3. Final recycle and energy reports verified and filed in city records. November 18, 2020: 1. Land development and engineering Chris Classen verified and approved, final Public Works/engineering department approvals and released hold on computer tracking system. 2. Final building inspection walk-through for: structural, plumbing, electrical, mechanical scope of work -approved per engineer and architects-plans details and specifications. 3. Final recycle and energy reports verified and filed in city records. Passed No Yes Yes Yes Page 3 of 4 PERMIT INSPECTION HISTORY for (CBC2020-0247) Permit Type: BLDG-Commercial Work Class: Tenant Improvement Status: Closed -Finaled Application Date: 06/25/2020 Owner: BECKMAN CARLSBAD I LLC Issue Date: 08/21/2020 Subdivision: CARLSBAD TCT#81-10 UNIT#02A Expiration Date: 04/06/2021 IVR Number: 27071 Address: 2231 RUTHERFORD RD, # 110 CARLSBAD, CA 92008-8820 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Primary Inspector Reinspection Inspection Checklist Item BLDG-Building Deficiency Status COMMENTS November 17, 2020: 1. Building final inspection not completed. 2. Chris Glasson with land development engineering department needs to provide site inspection prior to building and safety final inspection walk-through. 3. Dave/site superintendent informed land development engineering needs to do a final walk-through inspection prior to building inspection final walk-through. Contractor/superintendent will reschedule final inspection. 11/18/2020 11/18/2020 BLDG-Final Inspection 144047-2020 Passed Tony Alvarado Wednesday, November 18, 2020 Passed No Complete Page 2 of 4 Building Permit Inspection History Finaled (city of Carlsbad PERMIT INSPECTION HISTORY for (CBC2020-0247) Permit Type: BLDG-Commercial Application Date: 06/25/2020 Owner: BECKMAN CARLSBAD I LLC Work Class: Tenant Improvement Issue Date: 08/21/2020 Subdivision: CARLSBAD TCT#81-10 UNIT#02A Status: Closed -Finaled Expiration Date: 04/06/2021 Address: 2231 RUTHERFORD RD, # 110 IVR Number: 27071 CARLSBAD, CA 92008-8820 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 08/24/2020 08/2412020 BLDG-11 138433-2020 Passed Paul Burnette Complete Foundation/Fig/Piers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-84 Rough 138434-2020 Partial Pass Paul Burnette Relnspectlon Incomplete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 09101/2020 09/01/2020 BLDG-17 Interior 137201-2020 Passed Tim Kersch Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 09/16/2020 09/16/2020 BLDG-44 138372-2020 Partial Pass Paul Burnette Relnspectlon Incomplete Rough/Ducts/Dam pars Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 10/08/2020 10/08/2020 BLDG-85 T-Bar, Ceiling 140458-2020 Passed Paul Burnette Complete Grids, Overhead Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 11/17/2020 11/17/2020 BLDG-Final lnspaction 143921-2020 Cancelled Tony Alvarado Relnspectlon Incomplete Wednesday, November 18, 2020 Page 1 of4 ✓• EsG1I A SAFEbwilf Company DATE: 8-20-2020 JURISDICTION: Carlsbad PLAN CHECK#.: CBC2020-0247.RC2 PROJECT ADDRESS: 2231 Rutherford Rd. PROJECT NAME: Implus-Office TI SET: III ~PPLICANT 1 vURIS. ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. 0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. 0 The applicant's copy of the check list has been sent to: ~ EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted:/,. /,, '" Telephone#: Date contacted:~( LO/bf.Ab#Y/) Email: Mail Telephone Fax In Person 0 REMARKS: By: Ericll A. Kuchar, P.E. Enclosures: EsGil 7-27-20 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 ~--------·--···-···----- ' DA TE: 8-4-2020 JURISDICTION: Carlsbad ✓• EsG1I A SAFEbuilfCompany PLAN CHECK#.: CBC2020-0247.RC1 PROJECT ADDRESS: 2231 Rutherford Rd. PROJECT NAME: Implus-Office TI SET: II □ APPLICANT □ JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. J:8:1 The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: D EsGil staff did not advise the applicant that the plan check has been completed. J:8:1 EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Payge Daniel Telephone#: 858-922-9352 Date contacted: (by: ) Email: propm9r@beckprop.com Mail Telephone Fax In Person 0 REMARKS: By: Erich A. Kuchar, P.E. Enclosures: EsGil 7-27-20 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad CBC2020-0247.RC1 8-4-2020 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. GENERAL 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one oftwoways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. 2. Plans submitted in electronic format, if approved by the city, must have restrictions remove from the security settings. Electronic plans with restrictions to markups, printing, or stamping will not be approved. PLANS 3. On sheet EX1_0.0 update the following occupancy factors and egress plan/ door size were necessary and recalculate per table 1004.5 of the 2019 CBC; -"Open Office" shown on outside new deck should be classified as Assembly without fixed seats Unconcentrated using 15 not "Open Office" using 100. The outside deck is requiring an occupancy load factor of 15 as stated above NOT 50. Occupancy for 898 sft will be 60 people requiring 2 exits. Update plans as shown. 4. Provide complete structural details and calcs for new Non-Bearing Structural exterior wall and doorway. This must allow for vertical movement of the floor joists above with vertical slip connections but able to resist wind pressures for the project. Provide wind pressure calc as well. , ' DATE: 8-5-2020 JURISDICTION: Carlsbad PLAN CHECK#.: CBR2020-1648 ✓• EsG1I A SAFEbuilt'Company SET: I PROJECT ADDRESS: 7407 Lantana Terrace PROJECT NAME: SFR-Foundation Repair-Stem Wall At Garage D APPLICANT D JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: D EsGil staff did not advise the applicant that the plan check has been completed. ~ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Terry Montello Telephone#: 619-994-5557 Date contacted: (by: ) Email: permits@permitsinmotion.com Mail Telephone Fax In Person 0 REMARKS: By: Erich A. Kuchar, P.E. Enclosures: EsGil 7-23-2020 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK#.: CBR2020-1648 JURISDICTION: Carlsbad PROJECT ADDRESS: 7407 Lantana Terrace FLOOR AREA: 16'-0" of repair REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 7-21-2020 DATE INITIAL PLAN REVIEW COMPLETED: 8-5-2020 FOREWORD (PLEASE READ): STORIES: 1 HEIGHT: unknown DATE PLANS RECEIVED BY ESGIL CORPORATION: 7-23-2020 PLAN REVIEWER: Erich A. Kuchar, P.E. This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and stale laws regulating energy conservation, noise ·attenuation and .access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance .by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2019 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2018 IRC, 2018 IBC, 2018 UPC, 2018 UMC and 2017 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2018 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. • [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Erich A. Kuchar, P.E. BUILDING ADDRESS: 7407 Lantana Terrace BUILDING OCCUPANCY: R-3 PLAN CHECK#.: CBR2020-1648 DATE: 8-5-2020 BULDING AREA Vaklation Reg. VALUE ($} PORTION (Sq. Fl} Wtiplier Mod. Fol.l'ldation Reoai r Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction COde cb By Ordinance I 1997 UBC Building Permit Fee [~_) 7 f~1~iill: I 1997 UBC Plan Check Fee 1.1 c_,_,1 , ! :h.i tSII: Type ofRe\lew: r Complete Review r Structural Only r Repettt!YeFee r Other .. n;-i Repeats p Hou!:!! ~Hr.@• EaG■F-00 $105.ool ~ ~ ~ • Based on hourly rate No building valuation given, and no valuation can be found for foundation repair. Hourly review performed. Sheet 1 of 1 -A~ <-1.'' PLANNING DIVISION BUILDING PLAN CHECK REVIEW CHECKLIST P-28 Development Services Planning Division 1635 Faraday Avenue (760} 602-4610 www.carlsbadca.2ov ,-r,, ¥ C I TY OF CARLSBAD REVIEW#: 1 2 3 !ZI □□ l8l □ □ l8l □□ 181 □□ l8l □ □ l8l □□ Plan Check No. CBC2020-024 7 Address 2231 RUTHERFORD RD STE 11 O Date 7 f7 /20 Review# 1 Plann~SARAH CLUF; Phone (760) 602-4619 APN: 2120701900 .. Type of Project & Use: T.I. Net Project Density: DU/AC Zoning: C-M General Plan: .El Facilities Management Zone:§ CFO (In/out) ft.:...D'1e of participation: __ Remaining net dev acres: __ (For non-residential development: Type of land use created by this pennit: __ ) Legend: t8l Item Complete D Item Incomplete .. Needs your action Environmental Review Required: YES O NO O TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: YES O NO l8l TYPE __ APPROVAURESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: __ Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES ONO l8l CA Coastal Commission Authority? YES D NO D If California Coastal Commission Authority: Contact them at -7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402; (619) 767-2370 Detennine status (Coastal Permit Required or Exempt): Habitat Management Plan Data Entry Completed? YES O NO 0 If property has Habitat Type identified in Table 11 of HMP, complete HMP Pennit application and assess fees in Energov lncluslonary Housing Fee required: YES D NO D (Effective date of lnclusionary Housing Ordinance -May 21 , 1993.) Data Entry Completed? YES O NO 0 For construction of inclusionary units, email notification provided to HNS?: YES D NO D (Email Susan Steinkamp In HNS with project number and contact info) Housing Tracking Form (form P-20) completed: YES D NO D N/A ~ /,. .. ~ '\?I,&-,.. ~ CITY OF CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK REVIEW CHECKLIST P-28 DATE: 7/7/20 PROJECT NAME: PROJECT ID: PLAN CHECK NO: CBC2020-024 7 SET#: 1 ADDRESS: 223 Th is plan check review Is complete and has been Division. By: SARAH CLUFF Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.~ov A Final Inspection by the PLANNING Division is required ~~; Yes □ No You may a.fso have corrections from one or more of th~ divisions !lstcd below. Approval from these• divisions may be required prior to the Issuance of a building· perm it. Resubrnitted plans should Include co.rrections fro,n all divisions. [Zj This plan check review Is NOT COMPLETE. Items missing or Incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: PROPMGR@BECKPROP.COM For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVENTION 760-602--4610 760-602-2760 760-602-4665 i ] Hector Salgado -. 760-602-4624 .__. l:t~k1Q[,Salis1do®carl~bs1di;a,iQ~ r1 t_l Gina Ruiz 760-602-4675 Glas1,Buiz®i;ad~badi;a,g2~ r-;~ Sarah Cluff I ~ j v.;_.!., 760-602-4619 Sarah.tlu~~arl~ba~~a.i!o~ r __________________________________________ __ C City of Carlsbad PURPOSE CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 Development Services Building Division 1635 Faraday Avenue (760) 602-2719 www.carlsbadca.gov This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their projects. The completed checklist must be included in the building permit application. It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances. NOTE: The following type of permits are not required to fill out this form ❖ Patio I ❖ Decks I ❖ PME (w/o panel upgrade) I ❖ Pool ~ If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, an explanation must be provided to the satisfaction of the Building Official. ~ Details on CAP ordinance requirements are available on the city's website. ~ A CAP Building Plan template (form 8-55) shall be added to the title page all building plans. This template shall be completed to demonstrate project compliance with the CAP ordinances. Refer to the building application webpage and download the latest form . Project Name/Building Permit No.: Property Address/APN: Applicant Name/Co.: Applicant Address: Contact Phone: • ~ I • ., • • • ../ ' • ' • • ' • •• -~ ••.,. • • ' .. \~ /i ' , . It ., I•[ .I __________ BPNo.: Cl_S(2C>l[)-QL~l-: 2.2 31 Ru:t:w di)rd JZ.d .; cA--\~ \e \ \ Q WN ~ 2 I 1.. · c, o · o~ · co \ SOS U)V'YJQ~ So V)"te. !e. Or. s u ·, -ie \ a~ Contact Email: Contact information of person completing this checklist (if different than above): Name: Company name/address: Contact Phone: Contact Email: Applicant SignatureY~ c2.. k--- M,.1l~~lVCt ~!5'~ B-50 Page 1 of 6 Revised 08/19 City of Carlsbad Climate Action Plan Consistency Checklist Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project. For alterations and additions to existing buildings, attach Building Permit Valuation worksheet. Building Permit Valuation (BPV) from worksheet: $ 28/ ,03?-:-' Construction Type j Complete Sectlon(s) I Notes: D Residential □ New construction □ Additions and alterations: □ BPV < $60,000 □ BPV ~ $60,000 □ Electrical service panel upgrade only □ BPV ~ $200,000 -- G'Nonresidential □ New construction Iterations: PV ~ $200,000 or additions~ 1,000 square feet □ BPV ~ $1 ,000,000 □ ~ 2,000 sq. ft. new roof addition Checklist Item Low-rise I ~-3A N/A 1A, 4A 1A, 4A* High-rise I '"-2B, 3B, 4A N/A 4A 1B,4A* 1 B, 2B, 3B, 4B and 5 1B, 5 1B, 2B, 5 2B, 5 A high-rise residential building is 4 or more stories, including a mixed-use building in which at least 20% of its conditioned floor area is residential use All residential additions and alterations 1-2 family dwellings and townhouses with attached garages only *Multi-family dwellings only where interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed Building alterations of~ 75% existing gross floor area 1 B also applies if BPV ~ $200,000 Check the apprcpriate boxes, explain ft not applicable and exception items, and provide supporting calculations and doannenlation as necessary. 1. Energy Efficiency Please refer to Carlsbad Municipal Code (CMC) sections 18.21.155 and 18.30.190, and the California Green Building Standards Code (CAL Green) for more information when completing this section. A. D Residential addition or alteration l!: $60,000 building permit valuation. D N/A ________ _ See CMC section 18.30.190. D Exception: Home energy score~ 7 (attach certification) Year Built Single-family Requirements Multi-family Requirements D Before 1978 Select one: D Duct sealinq D Attic insulation □Cool roof D Attic insulation D 1978 and later Select one: D Lighting package D Water heating Package D Between 1978 and 1991 Select one: D Duct sealing D Attic insulation □Cool roof D 1992 and later Select one: D Lighting package D Water heating package ,,, B. Nonresidential* new construction or alterations:!: $200,000 building permit valuation, or additions:!: 1,000 square feel D N/A Updated 8/15/20 I 9 .,· ~ I 2 r eity ~f Carlsbad Climate Action Plan Consistency Checklist ' See CMC 18.21.155 and CALGreen Appendix AS, Division A5.2 -Energy Efficiency. AS.203.1.1 Choose one: D . 1 Outdoor lighting D .2 Warehouse dock seal doors 3 Restaurant service water heating (comply with California Energy Code section 140.5, as amended) 0 N/A ________ _ .4 Daylight design PAFs D .5 Exhaust air heat recovery AS.203.1.2.1 Choose one as applicable: D .95 Energy budget D .90 Energy budget 0 N/A AS.211.1 ** D On-site renewable energy 0 N/A AS.211.3** D Green power (if offered by local utility provider, 50% minimum renewable sources) D N/A AS.212.1 D Elevators and escalators 0 N/A AS.213.1 D Steel framing 0 N/A • Includes hotels/motels and high-rise residential buildings •• For alterations~ $1,000,000 BPV and affecting> 75% existing gross floor area, or alterations that add 2,000 square feet of new roof addition: comply with CMC 18.30.130 instead. 2. Photovoltaic Systems A. D Residential new construction (for low-rise residential building permit applications submitted after 1/1/20). Refer to 2019 California Energy Code section 150.1(c)14 for requirements. Notes: 1) High-rise residential buildings are subjectto nonresidential photovoltaic requirement (28 below) instead. 2) If project includes installation of an electric heat pump water heater pursuant to CMC 18.30.150(8) (high-rise residential) or 18.30.170(8) (low-rise residential), increase system size by .3kWdc if PV offset option is selected. Floor Plan ID (use additional CFA #<J.u. Calculated kWdc* sheets if necessary) Total System Size: kWdc = (CFAx.572) / 1,000 + (1.15 x #<J.u.) *Formula calculation where CFA = conditional floor area, #<Ju = number of dwellings per plan type If proposed system size is less than calculated size, please explain. Exception D D D D kWdc 8. D Nonresidential new construction or alterations 2!$1,000,000 8PV and affecting 2!75% existing floor area, or addition that increases roof area by 2!2,000 square feet. Please refer to CMC section 18.30.130 when completing this section. Note: This section also applies to high-rise residential and hotel/motel buildings. Choose one of the following methods: □ Gross Floor Area (GFA) Method GFA: □If < 10,000s.f. Enter: 5 kWdc Min. System Size: □ If ;;:: 1 O,OOOs.f. calculate: 15 kWdc x (GFA/10,000) •• kWdc **Round building size factor to nearest tenth , and round system size to nearest whole number. D Time-Dependent Valuation Method Updated 8/ I 5/201 9 3 City of Carlsbad Climate Action Plan Consistency Checklist Annual TDV Energy use:*** ______ x .80= Min. system size: ____ _ kWdc ***Attach calculation documentation using modeling software approved by the California Energy Commission. 3. Water Heating A. D Residential and hotel/motel new construction Please refer to CMC sections 18.30.150 and 18.30.170 when completing this section. D For systems serving individual dwelling units choose one: D Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise residential only) D Heat pump water heater AND PV system .3 kWdc larger than required in CMC section 18.30.130 (high rise residential hotel/motel) or CA Energy Code section 150.1 (c) 14 (low-rise residential) D Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher D Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors D Exception: D For systems serving multiple dwelling units, install a central water-heating system with all of the following: D Gas or propane water heating system D Recirculation system per CMC 18.30.150(B) (high-rise residential, hotel/motel) or CMC 18.30.1 ?0(B) (low- rise residential) D Solar water heating system that is either: D .20 solar savings fraction D .15 solar savings fraction, plus drain water heat recovery □Exception: B. D Nonresidential new construction Please refer to Carlsbad Ordinance CMC section 18.30.150 when completing this section. D Water heating system derives at least 40% of its energy from one of the following (attach documentation): D Solar-thermal D Photovoltaics D Recovered energy □Water heating system is (choose one): D Heat pump water heater D Electric resistance water heater(s) □Solar water heating system with .40 solar savings fraction D Exception: Updated 8/15/2019 >' ' 4 City of Carlsbad Climate Action Plan Consistency Checklist 5. D Transportation Demand Management (TOM): Nonresidential ONLY An approved Transportation Demand Management (TOM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT. City staff will use the table below based on your submitted plans to determine whether or nor your permit requires a TOM plan. If TOM is applicable to your permit, staff will contact the applicant to develop a site-specific TOM plan based on the permit details. Acknowledgment: Employee ADT Estimation for Various Commercial Uses EmpADTfor first 1,000 s.f. EmpADTI 1000 s.f.1 Office (all)2 20 Restaurant 11 Retaib 8 Industrial 4 Manufacturing 4 Warehousin 4 1 Unless otherwise noted, rates estimated from /TE Trip Generation Manual, 1 ()th Edition 13 11 4.5 3.5 3 1 2 For all office uses, use SANDAG rate of 20 ADT/1,000 sf to calculate employee ADT 3 Retail uses include shopping center, variety store, superm arket, gyms, pharmacy, etc. Other commercial uses may be subject to special consideration Sample calculations: Office: 20,450 sf 1. 20,450 sf/ 1000 x 20 = 409 Employee ADT Retail: 9,334 sf 1. First 1,000 sf= 8 ADT 2. 9,334 sf -1,000 sf= 8,334 sf 3. 8,334 sf / 1,000 x 4.5 + 8 = 46 Em lo ee ADT I acknowledge that the plans submitted may be subject to the City of Carlsbad's Transportation Demand Management Ordinance. I agree to be contacted should my permit require a TD plan and understand that an approved TOM plan is a condition of permit issuance. Date: Ul I 1t:1 /'20 Person other than Applicant be contacted for TDM compliance (if applicable): Name (Printed): ___________________ _ Phone Number: _____ _ Email Address: ___________________ _ Updated 8/15/2019 6 ' City ;f Carlsbad Climate Action Plan Consistency Checklist ' 4. Electric Vehicle Charging A D Residential New construction and major alterations* Please refer to Carlsbad Ordinance CMC section 18.21.140 when com letin this section. One and two-family residential dwelling or townhouse with attached garage: Done EVSE Ready parking space required D Exception : □Multi-family residential: D Exception · Total Parking Spaces EVSE Spaces Proposed Capable I Ready I I I Calculations: Total EVSE spaces = .10 x Total parking (rounded up to nearest whole number) EVSE Installed = Total EVSE Spaces x .50 (rounded up to nearest whole number) EVSE other= Total EVSE spaces -EVSE Installed (EVSE other may be "Capable," "Ready" or "Installed.") Installed I Total I *Major alterations are: (1) for one and two-family dwellings and townhouses with attached garages, alterations have a building permit valuation ~ $60,000 or include an electrical service panel upgrade; (2) for multifamily dwellings {three units or more without attached garages), alterations have a building permit valuation~ $200,000, interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed. B D Nonresidential new construction (includes hotels/motels) D Exception · Total Parking Spaces EVSE Spaces Proposed Capable I Ready I Installed I Total 10 2 I 5 I 1 I 8 Calculation: Refer to the table below: Total Number of Parkinq Spaces provided Number of required EV Spaces Number of required EVSE Installed Spaces □ 0-9 1 1 [ 10-25 2 1 f" 26-50 4 2 [ 51-75 6 3 □ 76-100 9 5 101-150 12 6 -151-200 17 9 201 and over 10 percent of total 50 percent of Required EV Spaces Updated 8/15/2019 5 El ectrical Efficacy Consulting, Inc. IENERGYICONSULTINGIDESIGNICOMPLIANCEI CALCTP ACCEPTANCE CERTIFICATION CORRECTION/DEFECIENTCIES/NOTES DATE: 10/27/2020 PROJECT: PACIFIC RIDGE PERMIT NUMBER: #CBC2020-0048 ENFORCEMENTAGENCY: CITY OF CARLSBAD SYSTEM EXEMPT ONSITE TESTING NOT REQUIRED AT CERTIFICATE# TC-A813666 Title 24 acceptance testing is not required for alterations of < 20 controlled luminaires per §141.0(b)2l, §141.0(b)2J, and §141.0(b)2K. Please review attached pages for code book references Dennis Phillips 858-335-9868 Electrical Efficacy Consulting, INC. 13100 KIRKHAMWAY, SUnE 205,PoWAY, CA 92064-7128 858/7 48-2060 858/7 48-0012-F AX CISB 1002594 ATICERTIFICATION #TC-A813666 ~~ V'oc/uJZ0-0~1 ~~ 1..2-?1 Ru~-J?P. 2016 ENERGY CODE Nonresidential ri,Ace ~ Resources TIiie 24, Part 6 Triggers Interior Lighting -Alterations Step 1: Applicable Lighting Alteration Sections• (fy Mandatory Requirements ® Prescriptive Requirements , Liqhtinl Control Indoor Lighting Acceptance Calculated Lighting Calculate Rated Controlsc Scope Classification' DeV1ces Systems Testing• Power Density Power Reduction §110.9 1 §130.1 §130.4 §140.6 §141.0 Using Area Category, Complete Building or Tailored Methods §141 0(b)21i YES YES YES YES no Entire Luminaire Alteration 2 Using Rated Power Reduction Method §141.0(b)21ii YES YES YES no YESE Using Area Category, Complete Building or Tailored Methods §141 0(b)2Ji m YES YES m no Luminaire Component Modification• Using Rated Power Reduction Method §141.0(b)2Jii Lighting Wiring Alterations 4 Tenns and Definitions m YES YES YES 1 Exceptions to the Energy Standards include: (al luminaire alterations or component modifications of portable luminaires. or those affixed to movable partitions. or excluded by §140.6(al3: and (bl where only 2 luminaires in an enclosed space are affected; (cl when disturbance of asbestos is directly caused by the modification or alteration (unless the luminaire modifications are made in conjunction with asbestos abatementl. 2 Entire Luminaire Alteration includes: (al removing and reinstalling a total of 10 percent or more of the existinij luminaires; or (bl replacing or adding entire luminaires; or (cl adding, removing, or replacing walls or ceilings along with any redesign of the lighting system. 3 Luminaire Component Modification includes: (al replacing the ballasts or drivers and the associated lamps in the luminaire; or (bl permanently changing the light source of the luminaire; or (cl changing the optical system of the luminaire. where 70 or more existing luminaires are modified either on any single floor of a building or. where multiple tenants inhabit the same floor. in any single tenant space, in any single year. Lamp replacements alone and ballast replacements alone shall not be considered a modification of the luminaire provided that the replacement lamps or ballasts are installed and powered without modifying the luminaire. Note: Lighting shall not prevent or disable the operation of any multi-level. shut-off. or daylighting controls. Step 2: Lighting Control Requirements YES no YESE YES YES no 4 Lighting Wiring Alteration includes: (al adding circuit feeding luminaires; or (bl replace. modify, or relocate wiring between a switch or panelboard and luminaires; or (cl replace lighting control panels. panelboards. or branch circuit wiring. Exception to requirements: lighting wiring alterations made only for the addition of lighting controls. Notes A All sections listed in the table are applicable to the scope of work listed in the left hand column. Read over these sections carefully to determine what parts of each section pertain to the project. This Step 1 table is intended to be used in conjunction with the Step 2 table, below. Both should be read carefully. B For additional equipment requirements. see litle 20. C Controls requirements differ based on scope and lighting design. See the Step 2 table below for more information. D Acceptance testing is not required for alterations of s 20 controlled luminaires per §141 21. §141 O(b)2J. and §141 O(b)2K. E 50% reduction for office. retail and hotel occupancies. 35% reduction for all other occurpancies. @ Mandatory Requirements Area Multi-Level Shut-OFF Automatic Demand Secondary Scope Classification Controls' Lilghting Controls' Daylighting Responsive DaylitZone §1301{a) Controls1 §130.1(c) Controls' Controls10 Controls §130.l(b) §1301(d) §130.1(8) §140.6(d) Using Area Category, Complete Building or Tailored Methods §141 .0(b)21i Entire Luminaire Alteration s 85% of lighting power allowance > 85% of lighting power allowance YES YES YES YES YES no YES no no no YES YES YES no Using Rated Power Reduction MethodF §141.0(b)21i1 YES no no no Using Area Category, Complete Building or Tailored Methods §141.0(bl2Ji Luminaire ComP.onent Modification s 85% of lighting power allowance > 85% of lighting power allowance Lighting Wiring Alterations Tenns and Definitions YES YES YES YES YES no YES YES 6 § 130 1 (a) -Area Controls: All luminaires shall be functionally controlled with manually switched ON and OFF lighting controls. Each area enclosed by ceiling-height partitions shall be independently controlled. 7 §130 l(b) -Multi-Level Lighting Controls: The general lighting of any enclosed area 100 square feet or larger. with a connected lighting load that exceeds 0.5W per ft2 shall meet the requirements of §130.l(b) or if lighting power is :S85% of allowance, the enclosed space must have a minimum of one step of 30-70%. § 130. l(cl -Shut-OFF Controls: In addition to lighting controls installed to comply with §1301(al and lbl. all installed indoor lighting shall be equipped with controls that meet the requirements of §1301(cl. ~ m no no no YES m YES no Using Rated Power Reduction Methodf §141.0(b)2Jii YES no no no YES YES no no 9 §130 l(d)-Automatic Daylighting Controls: Any altered luminaires providing general lighting that are in or are partially in daylit zones shall meet the requirements of §1301(dl2. 1 O § 130 1 (el -Demand Responsive Controls: Only required in altered spaces > 10.000ft' where alteration changes area. occupancy types, or increases lighting power per Table 141 0-E. Notes F Rated Power Reduction: Any multi-level. Shut-OFF or daylighting controls already in place must remain functional. ~ EnergyCodeAce.com 2016 Title 24, Port 6-Nonres1dentiol lnte1io1 Lighting-Alterations Trigge,s Pagel of 2 2016-11-18 Appendix JA5. All newly installed space-conditioning systems requiring a thermostat shall be equipped with a thermostat that complies with Reference Joint Appendix JA5; and ii. The duct system that is connected to the new or replaced space-conditioning system equipment shall be sealed, if the duct system meets the criteria of Sections 140.4(1)1 , 2 and 3, as confirmed through field verification and diagnostic testing, in accordance with the applicable procedures for duct sealing of altered existing duct systems as specified in Reference Nonresidential Appendix NA2, and conforming to the applicable leakage compliance criteria in Section 141 .0(b)20. EXCEPTION 1 to Section 141.0(b)2Eii: Duct Sealing. Buildings altered so that the duct system no longer meets the criteria of Sections 144 (1)1, 2, and 3 are exempt from the requirements of Subsection 141.0(b )2Eii. EXCEPTION 2 to Section 141.0(b)2Eii: Duct Sealing. Duct systems that are documented to have been previously sealed as confirmed through field verification and diagnostic testing in accordance with procedures in the Reference Nonresidential Appendix NA2 are exempt from the requirements of Subsection 141 .0(b )2Eii. EXCEPTION 3 to Section 141.0(b)2EII: Duct Sealing. Existing duct systems constructed, insulated or sealed with asbestos are exempt from the requirements of Subsection 141 .0(b)2Eii. F. Spaces with lighting systems installed for the first time shall meet the requirements of Sections 110.9, 130.0, 130.1, 130.2, 130.4, 140.3(c) 140.6, and 140.7. G. When the requirements of Section 130.1 (d) are triggered by the addition of skylights to an existing building and the lighting system is not recircuited, the daylighting control need not meet the multi-level requirements in Section 130.1 (d). H. New internally and externally illuminated signs shall meet the requirements of Sections 110.9, 130.3 and 140.8. I. Entire Luminaire Alterations. Entire luminaire alterations shall meet the following requirements: i. For each enclosed space, alterations that consist of either (a) removing and reinstalling a total of 10 percent or more of the existing luminaires; or (b) replacing or adding entire luminaires; or (c) adding, removing, or replacing walls or ceilings along with any redesign of the lighting system, shall meet the lighting power allowance in Section 140.6, and the altered luminaires shall meet the applicable requirements in Table 141 .0-E; or ii. For alterations where existing luminaires are replaced with new luminaires, and that do not include adding, removing, or replacing walls or ceilings along with redesign of the lighting system, the replacement luminaires in each office, retail, and hotel occupancy shall have at least 50 percent, and in all other occupancies at least 35 percent, lower rated power at full light output compared to the existing luminaires being replaced, and shall meet the requirements of Sections 130.1 (a}1, 2, and 3, 130.1(c)1A through C, 130.1(c)2, 130.1(c)3, 130.1(c)4, 130.1(c)5, 130.1(c)6A, and for parking garages 130.1 (c)7B. EXCEPTION 1 to Section 141 .0(b)2I. Alteration of portable luminaires, luminaires affixed to moveable partitions, or lighting excluded as specified in Section 140.6(a)3 .. EXCEPTION 2 to Section 141.0(b)2I. In an enclosed space where two or fewer luminaires are replaced or reinstalled. EXCEPTION 3 to Section 141.0(b)2I. Alterations that would directly cause the disturbance of asbestos, unless the alterations are made in conjunction with asbestos abatement. EXCEPTION 4 to Section 141.0(b)2I. Acceptance testing requirements of Section 130.4 are not required for alterations where lighting controls are added to control 20 or fewer luminaires. J. Luminaire Component Modifications. Luminaire component modifications in place that include replacing the ballasts or drivers and the associated lamps in the luminaire, permanently changing the light source of the luminaire, or changing the optical system of the luminaire, where 70 or more existing luminaires are modified either on any single floor of a building or, where multiple tenants inhabit the same floor, in any single tenant space, in any single year, shall not prevent or disable the operation of any multi-level, shut-off, or daylighting controls, and shall: OFFICE USE ONLY .. . SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE RECORD ID # __________________ 1 PLAN CHECK# __________________ 1 BP DATE G Business Contact C u \/4. KO Telephone# t l.DO · '-/20 · City lb Co.rlS~l1 Zip Code Cf ")..OD APN# 2-l1.·D7D ·Oct Plan File# -e... The following questions represen th acility's ac ivities, NOT the specific project description. PART I: FIRE DEPARTMENT -HAZARDOUS MATERIALS VISION: OCCUPANCY CLASSIFICATION: (not required for projects within the City of San Diego): Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Occupancy Rating: Facility's Square Footage (including proposed project): 1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 13. Corrosives 2. Compressed Gases 6. Oxidizers 10. Cryogenics 14. Other Health Hazards 3. Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials 15. None of These. 4. Flammable Solids 8. Unstable Reactives 12. Radioactives PART 11: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISION (HMO): If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Avenue, Suite 110, San Diego, CA 92123. Call (858) 505-6700 prior to the issuance of a building permit. FEES ARE REQUIRED Project Completion Date: Expected Date of Occupancy: 1. 2. 3. 4. 5. 6. 7. 8. YES NO (for new construction or remodeling projects) D Er Is your business listed on the reverse side of this form? (check all that apply). D (9--""Will your business dispose of Hazardous Substances or Medical Waste in any amount? D [i)./Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500 _ _.12ounds and/or 200 cubic feet? D ~ Will your business store or handle carcinogens/reproductive toxins in any quantity? D [il...--Will your business use an existing or install an underground storage tank? D [Q.--Will your business store or handle Regulated Substances (CalARP)? D ti:!Aill your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? D Q.,,,---Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to or realer than 1,320 allons? California's Above round Petroleum Stora e Act . • 0 CalARP Exempt I Date Initials 0 CalARP Required I Date Initials 0 CalARP Complete I Date Initials PART 111: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCD): Any YES" answer req1,1ir %<1.Slafnp from APCD 10124 Old Grove Road, San Diego, CA 92131 apcdcomp@sdcounty.ca.qov (858) 586-2650). [*No stamp required if Q1 Yes and Q3 Ye/; and Q4-Q6JIJQ]. l;N!)(\>llowing questions are intended to identify the majority of air pollution issues at th~ planning stage. Projects may require additional measures not i~fii,:ily trie~~ quest!ons. F?r comprehensive requirements contact APCD. Residences are typically exempt. except -those with more than one building' on ttte>pfoperty; single bu1ldrf)gs with more than four dwelling units: townhomes: condos; mixed-commercial use; deliberate burns: residences forming part of a larger project._['Exi::ludes garages & small outbuildings.] YES NO/ ~ ,.) , '-\ 1. D (g" Will the project disturb 160 square feet or more of existing building materials? C \ 1 , , , 2. D ~II any load supporting structural members be removed? Notification may be required 10 w r\ing days prior to commencing demolition. 3. D [j (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Has an asbestos survey been performed by a Certified Asbestos Consultant or Site Surveillance Technician? 4. D D (ANSWER ONLY IF QUESTION 3 IS YES) Based on the survey results, will the project disturb any asbestos containing material? Notification _ )Jlay be required 10 working days prior to commencing asbestos removal. 5. O W Will the project or associated construction equipment emit air contaminants? See the reverse side of this form or APCD factsheet (www.sdapcd.org/info/facts/permits.pdf) for typical equipment requiring an APCD permit. D (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school 6. D bounda -\- I dj,cl~,e under penalty of perjury that to the best of my knowledge and belief t e re7£~e;r.::e true and correct. "J L 4..-, 1<-. 5e,J(._'1< ON\ , ~--""~ t"", Me.,1_1'i&g., -= Name of Owner or Authorized Agent Signature of Owner or Au onzed Agent t, I t ?i l~O Date FOR OFFICAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: ________________________________ _ BY· DATE· I I EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMO' APCD COUNTY-HMO APCD COUNTY-HMO APCD 'A stamp in this box only exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may still apply. HM-~171 /OA/1S\ 4, LIST OF BUSINESSES WHICH REQUIRE REVIEW AND APPROVAL FROM THE COUNTY OF SAN DIEGO DEPARTMENT OF ENVIRONMENTAL HEALTH-HAZARDOUS MATERIALS DIVISION Check all that apply: AUTOMOTIVE D Battery Manufacturing/Recycling D Boat Yard D Car Wash D Dealership Maintenance/Painting D Machine Shop D Painting D Radiator Shop D Rental Yard Equipment D Repair/Preventive Maintenance D Spray Booth 0 Transportation Services D Wrecking/Recycling CHEMICAL HANDLING D Agricultural supplier/distributor D Chemical Manufacturer D Chemical Supplier/Distributor D Coatings/Adhesive D Compressed Gas Supplier/Distributor D Dry Cleaning D Fiberglass/Resin Application D Gas Station D Industrial Laundry D Laboratory D Laboratory Supplier/Distributor 0 Oil and Fuel Bulk Supply D Pesticide Operator/Distributor CHEMICAL HANDLING D Photographic Processing D Pool Supplies/Maintenance D Printing/Blue Printing D Road Coatings D Swimming Pool D Toxic Gas Handler D Toxic Gas Manufacturer METAL WORKING D Anodizing D Chemical Milling/Etching D Finish-Coating/Painting D Flame Spraying 0 Foundry D Machine Shop-Drilling/Lathes/Mills D Metal Plating D Metal Prepping/Chemical Coating D Precious Metal Recovery D Sand Blasting/Grinding D Steel Fabricator D Wrought Iron Manufacturing AEROSPACE D Aerospace Industry D Aircraft Maintenance D Aircraft Manufacturing OTHERS AND MISCELLANEOUS 0 Asphalt Plant D Biotechnology/Research D Chiropractic Office D Co-Generation Plant D Dental Clinic/Office D Dialysis Center D Emergency Generator D Frozen Food Processing Facility D Hazardous Waste Hauler D Hospital/Convalescent Home D Laboratory/Biological Lab D Medical Clinic/Office D Nitrous Oxide (NO,) Control System D Pharmaceuticals 0 Public Utility D Refrigeration System D Rock Quarry D Ship Repair/Construction D Telecommunications Cell Site D Veterinary Clinic/Hospital D Wood/Furniture Manufacturing/Refinishing ELECTRONICS D Electronic Assembly/Sub-Assembly D Electronic Components Manufacturing D Printed Circuit Board Manufacturing NOTE: THE ABOVE LIST INCLUDES BUSINESSES, WHICH TYPICALLY USE, STORE, HANDLE, AND DISPOSE OF HAZARDOUS SUBSTANCES. ANY BUSINESS NOT INCLUDED ON THIS LIST, WHICH HANDLES, USES OR DISPOSES OF HAZARDOUS SUBSTANCES MAY STILL REQUIRE HAZARDOUS MATERIALS DIVISION (HMO) REVIEW OF BUSINESS PLANS. FOR MORE INFORMATION CALL (858) 505-6880. LIST OF AIR POLLUTION CONTROL DISTRICT PERMIT CATEGORIES Businesses, which include any of the following operations or equipment, will require clearance from the Air Pollution Control District. CHEMICAL 47 -Organic Gas Sterilizers 32 -Acid Chemical Milling 33 -Can & Coil Manufacturing 44 -Evaporators, Dryers & Stills Processing Organic Materials 24 -Dry Chemical Mixing & Detergent Spray Towers 35 -Bulk Dry Chemicals Storage 55 -Chrome Electroplating Tanks COATINGS & ORGANIC SOLVENTS 27 -Coating & Painting 37 -Plasma Arc & Ceramic Deposition Spray Booths 38 -Paint, Stain & Ink Mfg 27 -Printing 27 -Polyester Resin/Fiberglass Operations METALS 18 -Metal Melting Devices 19 -Oil Quenching & Salt Baths 32 -Hot Dip Galvanizing 39 -Precious Metals Refining ORGANIC COMPOUND MARKETING (GASOLINE, ETC) 25 -Gasoline & Alcohol Bulk Plants & Terminals 25 -Intermediate Refuelers 26 -Gasoline & Alcohol Fuel Dispensing COMBUSTION 34 -Piston Internal -Combustion Engines 13 -Boilers & Heaters (1 million BTU/hr or larger) 14 -Incinerators & Crematories 15 -Burn Out Ovens 16 -Core Ovens 20 -Gas Turbines, and Turbine Test Cells & Stands 48 -Landfill and/or Digester Gas Flares ELECTRONICS 29 -Automated Soldering 42 -Electronic Component Mfg FOOD 12 -Fish Canneries 12 -Smoke Houses 50 -Coffee Roasters 35 -Bulk Flour & Powered Sugar Storage SOLVENT USE 28 -Vapor & Cold Degreasing 30 -Solvent & Extract Driers 31 -Dry Cleaning ROCK AND MINERAL 04 -Hot Asphalt Batch Plants 05 -Rock Drills 06 -Screening Operations 07 -Sand Rock & Aggregate Plants 08 -Concrete Batch, CTB, Concrete Mixers, Mixers & Silos 10 -Brick Manufacturing OTHER 01 -Abrasive Blasting Equipment 03 -Asphalt Roofing Kettles & Tankers 46 -Reverse Osmosis Membrane Mfg 51 -Aqueous Waste Neutralization 11 -Tire Buffers 17 -Brake Debonders 23 -Bulk Grain & Dry Chemical Transfer & Storage 45 -Rubber Mixers 21 -Waste Disposal & Reclamation Units 36 -Grinding Booths & Rooms 40 -Asphalt Pavement Heaters 43 -Ceramic Slip Casting 41 -Pertite Processing 40 -Cooling Towers -Registration Only 91 -Fumigation Operations 56 -WWTP (1 million gal/day or larger) & Pump Station NOTE: OTHER EQUIPMENT NOT LISTED HERE THAT IS CAPABLE OF EMITTING AIR CONTAMINANTS MAY REQUIRE AN AIR POLLUTION CONTROL DISTRICT PERMIT. IF THERE ARE ANY QUESTIONS, CONTACT THE AIR POLLUTION CONTROL DISTRICT AT (858) 586-2600. HM-9171 /08/15\ Countv of San Dieon -DEH -Hazardous Materials Division ENCINA WASTEWATER AUTHORITY INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY 6200 Avenida Encinas, Carlsbad, CA 92011 Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinajpa.com • • Date: l.o}JOt /IJ...O Business Name: \mp1u,S Foote are-. L-L.C Street Address: 2Zo\ 12.l kbAO r-fo::::6 eA s, ,\.I :le \ l 0 J Email Address: Bcca'\":f e Vlfl u ~CD(> LC>YY\ PLEASE CHECK HERE IF YOUR 8 tNESS IS EXEMPT: (ON REVERSE SIDE CHECK TYPE OF BUSINESS) ~ Check all below that are present at your facility: o Acid Clea ning o Assembly o Automotive Repair o Battery Manufacturing o Biofuel Manufacturing o Biotech Laboratory o Bulk Chemical Storage o Car Wash o Chemical Manufacturing o Chemical Purification o Dental Offices • Dental Schools • Dental Clinics o Dry Cleaning o Electrical Component Manufacturing o Fertilizer Manufacturing o Fi lm/X-ray Processing o Food Processing o Glass Manufacturing o Industrial Laundry o Ink Manufacturing o Laboratory o Machining/Milling o Membrane manufacturing (i.e. water filter membranes) o Metal Casting/Forming o Metal Fabrication o Metal Finishing • Electroplating • Electroless Plating • Anodizing • Coating (i.e. phosphating) • Chemical Etching/Milling • Printed Circuit Board Manufacturing o Metal Powders Forming o Nutritional Supplement/Vitamin Manufacturing o Painting/Finishing o Paint Manufacturing o Personal Care Products Manufacturing o Pesticide Manufacturing/ Packaging o Pharmaceutical Manufacturing (including precursors) o Porcelain Enameling o Power Generation o Print Shop o Research and Development o Rubber Manufacturing o Semiconductor Manufacturing o Soap/Detergent Manufacturing o Waste Treatment/Storage New Business? YesO NoO SIC Code(s) if known: ______ Date operation began/will begin: ______ _ Tenant Improvement? YesONo[J If yes, briefly describe improvement: _________________ _ Description of operations generating wastewater (discharged to sewer, hauled or evaporated): .JUN 2 5 2020 Estimated volume of industrial wastewater to be discharged (gal/ day): __________________ _ list hazardous wastes generated (type/volume): __________________________ _ Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority? YesD Date: ____ No□ Page 1 of 2 •• ENCINA WASTEWATER AUTHORITY INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY 6200 Avenida Encinas, Carlsbad, CA 92011 Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinajpa.com The commercial enterprises listed below are a partial listing of businesses that are exempt from industrial wastewater discharge permitting under normal operating conditions. They are exempt because (a) they discharge no process wastewater (i.e., they only discharge sanitary wastewater with no pollutants exceeding any local limits), and (b) they have no potential to \ negatively impact the EWPCF or other wastewater treatment plants in the ESS. Any questions regarding exemptions should be referred to EWA Source Control staff. o Automobile Detailers o Hotels/Motels (no laundry) o Barber/Beauty Shops o Laundromats o Business/Sales Offices o Libraries o Cleaning Services o Medical Offices (no x-ray developing) o Carpet/Upholstery o Mortuaries o Childcare Facilities o Museums o Churches o Nail Salons o Community Centers o Nursing Homes o Consulting Services ~Office Buildings (no process flow) o Contractors o Optical Services o Counseling Services o Pest Control Services (no pesticide repackaging for sale) o Educational Services (no auto repair/film developing) o Pet Boarding/Grooming Facilities o Financial Institutions/Services o Postal Services (no car wash/auto repair) o Fitness Centers o Public Storage Facilities o Gas Stations (no car wash/auto repair) o Restaurants/Bars o Grocery Stores (no film developing) o Retail/Wholesale Stores (no auto repair/film developing) o Residential based Businesses o Theaters (Movie/Live) CERTIFICATION STATEMENT I certify that the information above is true and correct to the best of my knowledge. ENCINA WASTEWATER AUTHORITY DATE: ~ !11(.:i.-o ( 6200 AVENIDA ENCINAS, CARLSBAD, CA Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinajpa.com Page 2 of 2