Loading...
HomeMy WebLinkAbout2701 ROOSEVELT ST; ; CBRA2018-0234; PermitBuilding Permit Finaled {'city of Carlsbad Residential Associated Permit Print Date: 12/04/2020 Job Address: 2701 ROOSEVELT ST, CARLSBAD, CA 9200B PermitType: BLDG-Associated Permit Residential Work Class: Parcel#: 2031013812 Track#: Valuation: $~t9MM ~~ Occupancy Group: #of Dwelling Units: 1 Project#: Plan#: Bedrooms: 3 Construction Type: Condo CT140007 12 DEV04098 Bathrooms: 3.0 Orig. Plan Check#: PC2018-0019 Plan Check#: Project Title: BEACHWALK AT ROOSEVELT Permit No: CBRA2018-0234 Status: Applied: Issued: Finaled Close Out: Closed -Finaled 11/15/2018 01/11/2019 Inspector: MColl Final Inspection: 12/04/2020 Description: BEACHWALK AT ROOSEVELT: BLDG 5 // UNIT 12 // PLAN B // 1,634 SF LIV// 433 SF GARAGE// 2115F DECK Applicant: VESTA PROPERTIES GEOFF MCCOMIC 18181ST AVE SAN DIEGO, CA 92101-2662 (616) 481-3830 FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -outside CFD SB1473 GREEN BUILDING STATE STANDARDS FEE SEWER CONNECTION FEE (General Capacity all areas) STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1-Medium BLDG SWPPP PLAN REVIEW FEE TIER 1-MEDIUM TRAFFIC IMPACT Residential Condo Outside CFD TRAFFIC IMPACT Residential Condo Outside CFD Total Fees: $19,022.40 Total Payments To Date: Building Division $15,966.40 Balance Due: 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov AMOUNT $1,225.95 $789.51 $66.00 $175.00 $92.00 $182.00 $9,413.97 $11.00 $960.00 $34.97 $246.00 $58.00 $2,712.00 $3,056.00 $3,056.00 Page 1 of 1 PERMIT INSPECTION HISTORY for (CBRA2018-0234) Permit Type: BLDG-Associated Permit Residenti, Application Date: 11/15/2018 Owner: Work Class: Condo Issue Date: 01/11/2019 Subdivision: Status: Closed -Finaled Expiration Date: 09/08/2020 Address: 2701 ROOSEVELT ST IVR Number: 15501 CARLSBAD, CA 92008 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Relnspectlon Inspection Date Start Date Status Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-17 Interior Lath-Drywall Yes BLDG-18 Exterior Lath and Yes Drywall BLDG-23 Gas-Test-Repairs Yes BLDG-Fire Final 104267-2019 Failed Felix Salcedo Relnspectlon Incomplete Checklist Item COMMENTS Passed FIRE-Building Final No 08/1112020 08/11/2020 BLDG-Electric Meter 135334-2020 Passed Mlchael Collins Complete Release Checklist Item COMMENTS Passed BLDG-Building Deficiency EMR emailed to SDGE Yes 12104/2020 1210412020 BLDG-Final Inspection 145406-2020 Passed Peter Dreibelbis Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Flnal Yes BLDG-Structural Final Yes BLOG-Electrical Final Yes Friday, December 4, 2020 Page 3 of 3 PERMIT INSPECTION HISTORY for (CBRA2018-0234) Permit Type: BLDG-Associated Permit Residenti, Application Date: 11/15/2018 Owner: Work Class: Condo Issue Date: 01/11/2019 Subdivision: Status: Closed -Finaled Expiration Date: 09/08/2020 Address: 2701 ROOSEVELT ST IVR Number: 15501 CARLSBAD, CA 92008 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Re inspection Inspection Date Start Date Status 02/06/2020 02/08/2020 BLDG-14 118656-2020 Failed Michael Colllns Relnspectlon Incomplete Frame/Steel/Bolting/We ldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency 2/06/20. Need approved revisions to plans. No BLOG-Building Deficiency 3rd floor, floor sheathing and drag nailing Yes BLDG-Building Deficiency 2nd floor, floor sheathing and drag nailing Yes 02/20/2020 02/20/2020 BLDG-81 Underground 119850-2020 Failed Michael Colllns Relnspection Incomplete Combo(11, 12,21,31) Checklist Item COMMENTS Passed BLDG-Building Deficiency No superintendent available. No 02/24/2020 02/24/2020 BLDG-81 Underground 120148-2020 Passed Michael Colllns Complete Combo(11, 12,21,31) Checklist Item COMMENTS Passed BLDG-Building Deficiency No superintendent available. No BLDG-21 New 1st floor shower waste only Yes Underground-Underfloor Plumbing 03/04/2020 03/04/2020 BLDG-84 Rough 121450-2020 Passed Michael Colllns Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Minor pickup, see superintendent for list. Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 03/06/2020 03/06/2020 BLDG-16 lnsulatlon 121574-2020 Passed Peter Dreibelbis Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 03/12/2020 03/12/2020 BLDG-17 Interior 122143-2020 Passed Michael Colllns Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-82 Drywall, 122230-2020 Passed Michael Colllns Complete Exterior Lath, Gas Test, Hot Mop Friday, December 4, 2020 Page 2 of 3 Building Permit Inspection History Finaled Ccityof Carlsbad PERMIT INSPECTION HISTORY for (CBRA2018-0234) Permit Type: BLDG-Associated Permit Residenti, Application Date: 1111512018 Owner: Work Class: Condo Issue Date: 01/11/2019 Subdivision: Status: Closed -Finaled Expiration Date: 0910812020 Address: 2701 ROOSEVELT ST IVR Number: 15501 CARLSBAD, CA 92008 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 03/05/2020 BLDG-14 121573-2020 Cancelled Michael Collins Relnspectlon Incomplete Frame/Steel/Bolting/We ldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency 2/06/20. Need approved revisions to plans. No BLDG-Building Deficiency 3rd floor, floor sheathing and drag nailing Yes BLOG-Building Deficiency 2nd floor, floor sheathing and drag nailing Yes 02/27/2019 02/27/2019 BLDG-21 084780-2019 Passed Mlchael Collins Complete Underground/Underflo or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Waste lo POC Yes 0412312019 04/2312019 BLDG-11 089713-2019 Passed Michael Collins Complete Foundation/Fig/Piers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Ufer ok Yes 06/12/2019 06/12/2019 BLDG-14 094478-2019 Partial Pass Michael Collins Relnspectlon Incomplete Frame/Steel/Bolting/We ldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency 2nd floor, floor sheathing and drag nailing Yes 07/02/2019 07/02/2019 BLDG-14 096333-2019 Partial Pass Michael Collins Reinspection Incomplete Frame/Steel/Bolting/We !ding (Decks) · Checklist Item COMMENTS Passed BLDG-Building Deficiency 3rd floor, floor sheathing and drag nailing Yes BLDG-Building Deficiency 2nd floor, floor sheathing and drag nailing Yes 09/04/2019 09/04/2019 BLDG-15 Roof/ReRoof 102991-2019 Partial Pass Chris Renfro Relnspectlon Incomplete (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency See back of card. Yes 10/31/2019 10/31/2019 BLDG-13 Shear 109400-2019 Passed Mlchael Colllns Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Need housekeeping on entire job Yes Friday, December 4, 2020 Page 1 of 3 GEOTECHNICAL I ENVIRONMENTAL I MATERIALS PROJECT NO.: 3447-S03 DATE: 4-15-2019 GEOTEK FIELD TESTING REPORT NAME: Metcalfe HOURS: _____ _ CLIENT Vesta Pacific' SUPT. Raul Aquinaga PROJECT Beachwalk at Roosevelt LOCATION Carlsbad ---------- CONTRACTOR Verdugo ----"---------------- EQUIPMENT None --------------------------------------- SUBJECT Foundations for Units Listed Below Test No. Location NO TESTS TAKEN COMMENTS: Observed soil conditions for following: Unit 12, 270 I Roosevelt, CBRA 2018-0234 Unit 13, 2703 Roosevelt, CBRA 2018-0235 Unit 14, 2705 Roosevelt, CBRA 2018-0236 Unit 15, 2709 Roosevelt, CBRA 2018-0237 Unit 16, 271 I Roosevelt, CBRA 2018-0238 Elev. Moisture Dry Content% Density % Relative % Required Soil Type Pass or Compaction Compaction /Max TestType Fail Foundation Excavations are in compliance with the geotechnical recommendations, care should be taken to remove an loose soil/slough in trenches before pouring. The backfill for what is apparently the sewer cleanout for Unit I 5 has sloughed into excavation and needs to be removed before concrete is poured. Soil should be moist when concrete is poured. / SUPERINTEDENT: COMPANY: :·~ Page I of I --'----- IC:INC51 ! DaoPEC I iuN IIEII.VICE8 ! SPECIAL INSPECTION DAILY REPORT 3406 Texas Street San Diego, CA, 92104 619-261-9022 desmond@Kingisi.com www.Kingisi,com Special Inspection Reports shall be prepared on a Daily Basis. All Non-Compliant conditions must be reported IMMEDIATELY to the Superintendent. Each Inspection Report shall be completed and signed by the Special Inspector conducting the Inspection/ Testing. Project Name: Roosevelt Apartments / Date: 10/17/19 Bulldlna Permit#: DUIIO l'I':;), Unit,.,.,.... ',u•_,._..,.,. Time Arrived: 7am Prolect Location: 2670 Hooseve1t :::itreet, vansoaa, '-'"• 92008 Time Deoarted: Contractor: Vesta Pacific Development Architect Sub-Contractor: UPF Engineer: Inspection/ Material Description Sheathina, Anchors, nailina, straos, clios Samnles Ticket No#: AirTemo: !Concrete Temo: @ Mins. I Siu mo : I I Approved Drawings; SN-1, General notes Work lnsmlcted: lnspec1on and Observation continues for Interior and Exterior Shearwalls. Verified stamped sheathing secured·inplaceiAII nails driven flush and staggered. Walls #2: 8d's@4/12, #3:3/12. #4 and #5: 2112. All Header, Straps, J3iocking, A35 Clips and Brackets per Shearwall Schedule. Holddown / anchors in place per plan schedule, engineers-details.-·- Hours: 4 Note : Parli.31 interio(insfili<::lioh, Anparty Vl'alls: ~fletplu111bing,jTectrica~gasj:ilace~enl a.ndi!!SUlation will be - palace .and wall closed, Firestop_@to'0'\ City inspector will verify prior1o building being rapped:· Report emailed to Super Raul WORK: ~ ~ INSPECTED l~NCE WITH THE REQUIREMENTS OF THE APPROVED DOCUMENTS. MATERIAL SAMPLING:-~ INSPECTED IN ACCORDANCE WITH T~EQ~S C/ OF THE APPROVED DOCUMENTS. LAB ID ATTACHED, SAMPLES SCHEDULED FOR PICK-UP THE WORK INSPECTED: -BiPJP NOJ MffI --- ~ Signature of Special Inspector: Print Name; Desmond King CERTIFICATION #: SD #1169, ICC #8132156 Signature of Superintendent"¥; GeoTek, Inc. I 548 North Maple Street, Corona. California 92880 (951) 710-1160 Office (951) 710-1167 Fax www.geotekusa.com DAILY INSPECTION REPORT CLIENT: Vesta pacific development PROJECT NO: 3447-SD -------- PROJECT: ::..;Roos=e::..:v.:::elt'----.,-,,,..,----------------DATE: 04/16/19 PROJECT LOCATION: a-'>O I Roosevelt. Carlsbad. CA CONTRACTOR: Verdugo construction PLANS BY: Gouvis engineer DATED: ------BUILDING PERMIT NO:C.f7/lA20I 8-023 '( APPROVED BY: Carlsbad Pc201s-oo19 DATED: ____ _ TYPE OF INSPECTION: Rebar SHEETS & DETAILS: LOCATION OF INSPECTION: _Se=e.:cbe:::lo:::w _________________________ _ The following items were observed and / or tested: Inspection and observation continues for SOG / FTG reinforcement for Building #5, Unit 12, 13 and 14, Building #6, units 15 and 16. Pennijs #CBRA2018·0234, #CBRA2018-0235, #CBRA2018-0236, #CBRA2018-0237, #CBRA2018-0238. Verified rebar is securely tied, with laps, ties and clearance in place. Cont (2)#4 TB, #4@24• ocew for SOG, Reinforcement for spread FTGs, {4)#4ocew, (6)#4ocew, (7)#5ocew, All Pad FTGs verified, P3, P4, PS and P7 per Pad Schedute. FTGs are debris free, Anchors in placed for Sill plates, Simpsons Strong.walls and HDUs, Visqueen topped with 2" clean sand. 2" Dobies being placed. General Notes, SN1, SO1, exterior FTGs, foundation plans, Holddowns schedule. 2500psi concrete to be scheduled. TSO. Raguinaga@vestapacificdevelopment.com PAGE _1 ____ OF ____ _ ~Work observed during this inspection substantially complies to approved plans and specifications. D Not Complete. Work observed is still in progress and will require additional inspections. 4 Hours: __________ _ Signature SUPERVISOR: ~ Desmond King S0#1169 /8132156 Print Name GEOTECHNICAL I ENVIRONMENTAL I MATERIALS