Loading...
HomeMy WebLinkAbout2695 ROOSEVELT ST; ; CBRA2018-0231; PermitBuilding Permit Finaled Ccityof Carlsbad Residential Associated Permit Print Date: 12/07/2020 Job Address: 2695 ROOSEVELT ST, CARLSBAD, CA 92008 Permit Type: BLDG-Associated Permit Residential Work Class: Parcel#: 2031013809 Track#: Valuation: $267,769.30 Lot#: Occupancy Group: #of Dwelling Units: 1 Project#: Plan#: Bedrooms: 3 Construction Type: Condo CT140007 9 DEV04098 Bathrooms: 3.0 Orig. Plan Check#: PC2018-0019 Plan Check#: Project Title: BEACHWALK AT ROOSEVELT Permit No: CBRA2018-0231 Status: Applied: Issued: Fina led Close Out: Closed -Fina led 11/15/2018 01/11/2019 Inspector: MColl Final Inspection: 12/07/2020 Description: BEACHWALK AT ROOSEVELT: BLDG 1 // UNIT 9 //PLANA// 1,623 SF LIV// 434 SF GARAGE// 232 SF DECK Applicant: VESTA PROPERTIES GEOFF MCCOMIC 1818 lSTAVE SAN DIEGO, CA 92101-2662 (616) 481-3830 FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -outside CFO SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL Total Fees: $11,942.37 Total Payments To Date: Building Division $11,942.37 Balance Due: 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov AMOUNT $1,222.40 $787.23 $66.00 $175.00 $92.00 $182.00 $9,371.93 $11.00 $34.81 $0.00 Page 1 of 1 PERMIT INSPECTION HISTORY for (CBRA2018-0231) Permit Type: BLDG-Associated Permit Residenti, Application Date: 11/15/2018 Owner: Work Class: Condo Issue Date: 01/11/2019 Subdivision: Status: Closed -Finaled Expiration Date: 01/25/2021 Address: 2695 ROOSEVELT ST IVR Number: 15498 CARLSBAD, CA 92008 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspectlon Inspection Date Start Date Status BLDG-17 Interior 116382-2020 Cancelled Michael Collins Relnspectlon Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 01/29/2020 01/29/2020 BLDG-17 lntertor 117783-2020 Partial Pass Michael Collins Relnspectlon Incomplete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Drywall only Yes 02/13/2020 02/13/2020 BLDG-17 Interior 119364-2020 Passed Michael Collins Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Drywall only Yes BLDG-Building Deficiency Yes BLDG-18 Exterior 119353-2020 Passed Michael Collins Complete Lath/Drywall Checklist Item COMMENTS Passed BLOG-Building Deficiency Yes 07/29/2020 07/29/2020 BLDG-11 134072-2020 Partial Pass Michael Collins Relnspectlon Incomplete Foundatlon/Ftg/Plars (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Deck column footing/steel Yes 08/10/2020 08/10/2020 BLDG-Electric Matar 135189-2020 Passed Michael Colllns Complete Release Checklist Item COMMENTS Passed BLDG-Building Deficiency EMR emailed to SDGE Yes 12/07/2020 12/07/2020 BLDG-Flnal Inspection 145553-2020 Passed Peter Drelbelbls Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes Monday, December 7, 2020 Page 3 of 3 PERMIT INSPECTION HISTORY for (CBRA2018-0231) Permit Type: BLDG-Associated Permit Residenti, Application Date: 11/15/2018 Owner: Work Class: Condo Issue Date: · 01/11/2019 Subdivision: Status: Closed -Finaled Expiration Date: 01/25/2021 Address: 2695 ROOSEVELT ST IVR Number: 15498 CARLSBAD, CA 92008 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Relnspectlon Inspection Date Start Date Status 06/28/2019 06128/2019 BLDG-14 096010-2019 Failed Michael Collins Relnspectlon Incomplete Frame/SteeUBolting/Wo !ding (Decks) Checklist item COMMENTS Passed BLDG-Building Deficiency Not ready, no super on site No BLDG-Building Deficiency 2nd floor, floor sheathing and drag nailing Yes BLDG-Building Deficiency Not ready No 07/02/2019 07/02/2019 BLDG-14 096494-2019 Partial Pass Michael Collins Relnspectlon Incomplete Frame/Stool/Bolting/We !ding (Docks) Checklist Item COMMENTS Passed BLDG-Building Deficiency 2nd floor, floor sheathing and drag nailing Yes BLDG-Building Deficiency 3rd floor, floor sheathing and drag nailing Yes BLDG-Building Deficiency Not ready, no super on site No BLDG-Building Deficiency Not ready No 08/30/2019 08/30/2019 BLDG-15 Roof/RoRoof 102692-2019 Partial Pass Michael Collins Relnspectlon Incomplete (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Sheathing/strap nailing only Yes 10/21/2019 10/21/2019 BLDG-13 Shear 108106-2019 Failed Michael Colllns Relnspectlon Incomplete Panels/HD (ok to wrap) Checklist item COMMENTS Passed BLDG-Building Deficiency Not ready No 10/22/2019 10/22/2019 BLDG-13 Shear 108286-2019 Passed Michael Colllns Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLOG-Building Deficiency Minor pick up Yes BLDG-Building Deficiency Not ready No 01/10/2020 01/10/2020 BLDG-14 116027-2020 Passed Paul York Complete Frame/Stool/Botting/We lding (Docks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready Yes BLDG-Building Deficiency 2nd floor, floor sheathing and drag nailing Yes BLDG-Building Deficiency Not ready, no super on site Yes BLDG-Building Deficiency 3rd floor, floor sheathing and drag nailing Yes 01/15/2020 01/15/2020 BLDG-16 lnsulatlon 116573-2020 Passed Michael Colllns Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes Monday, December 7, 2020 Page 2 of 3 Building Permit Inspection History Finaled {city of Carlsbad PERMIT INSPECTION HISTORY for (CBRA2018-0231} Permit Type: BLDG-Associated Permit Residenti: Application Date: 11/15/2018 Owner: Work Class: Condo Issue Date: 01/11/2019 Subdivision: Status: Closed -Finaled Expiration Date: 0112512021 Address: 2695 ROOSEVELT ST IVR Number: 15498 CARLSBAD, CA 92008 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Re inspection Inspection Date Start Date Status 02/26/2019 02/26/2019 BLDG-21 084645-2019 Passed Michael Collins Complete Underground/Underlto or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Waste to POC only Yes 04110/2019 04110/2019 BLDG-11 088477-2019 Failed Michael Collins Relnspectlon Incomplete Foundation/Fig/Piers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready, need electrical sub feed below No grade 0411512019 04/1512019 BLDG-11 088924-2019 Passed Michael Collins Complete Foundation/Fig/Piers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready, need electrical sub feed below No grade BLDG-Building Deficiency Ufer ok, see CBRA2018-0223 for conduit Yes notes 06/07/2019 06/07/2019 BLDG-14 094156-2019 Failed Michael Collins Relnspectlon Incomplete Frsme/Steel/Boltlng/We ldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No 06/10/2019 06/10/2019 BLDG-14 094250-2019 Partial Pass Michael Collins Re Inspection Incomplete Frame/Steel/Bolting/We ldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No BLDG-Building Deficiency 2nd floor, floor sheathing and drag nailing Yes 06/27/2019 06/27/2019 BLDG-14 095958-2019 Failed Michael Collins Relnspectlon Incomplete Frsme/Steel/Boltlng/We ldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency 2nd floor, floor sheathing and drag nailing Yes BLDG-Building Deficiency Not ready, no super on site No BLDG-Building Deficiency Not ready No Monday, December 7, 2020 Page 1 of3 ICKNGI ! lll8PECTIOII IIEllY'ICE8 ! SPECIAL INSPECTION DAILY REPORT 3406 Texas Street San Diego, CA, 92104 619-261-9022 desmond@Kingisi.com www.Kingisi.com Special Inspection Reports shall be prepared on a Daily Basis. All Non-Compliant conditions must be reported IMMEDIATELY to the Superintendent. Each Inspection Report shall be completed and signed by the Special Inspector conducting the Inspection/ Testing. Project Name: Roosevelt Apartments I Date: 10/17/19 Bulldina Permit#: Build #1 Unit #9. CBRA2018-0231 Time Arrived: 7am Prolect Location: oe.v 75 HOOSeve1t ;:,tree!, vansoaa, l,jA, 92008 Time Denarted: Contractor: Vesta Pacific Development Architect: Sub-Contractor: UPF Engineer: Inspection / Material Description Sheathinq, Anchors, nailina, strans, clips Samnles Ticket No#: AirTemo: I Concrete Temo : @ Mins. I Slumn : I I Approved Drawings; SN-1 , General notes Work lns~cted: lnspec1on and Observation conttnues for Interior and Exterior Shearwalls. Verified stamped sheathing secured in place, All nails driven flush and staggered: Walls #2:8d's@4/12, 113:3/12. #4 a.hd #5: 2/12. . ... AH Header, Straps, Blocking, A35 Clips arid Brackets per ShearwalLSchedule .. Holddown I anchors in place per plan schedule, engineers details. Hours: 4 Note :Partial interior inspe<:tion, i\llpartywalls: After plumbing, electrjcal, gas pla.cement and insula.Uori wiHt>e palace and wall closed, Fire stop @10'0". City inspector will verify prior to building being rapped, Report emailed to Super Raul WORK: ~ ~ INSPECTED l~NCE WITH THE REQUIREMENTS OF THE APPROVED DOCUMENTS. MATERIAL SAMPJJNG~ ~ INSPECTED IN ACCORDANCE WITH T~REQ~S C/ OF THE APPROVED DOCUMENTS. LAB ID ATTACHED, SAMPLES SCHEDULED FOR PICK-UP THE WORK INSPECTED: BPIP NOJMEEI Signature of Special Inspector: ~ Print Name: Desmond King CERTIFICATION#. SD #1169, ICC #8132156 Signature of Superintendent: ti; GeoTek, Inc. 1548 North Maple Street, Corona, California 92880 (951) 710-1160 Office (951) 710-1167 Fax www.geotekusa.com DAILY INSPECTION REPORT CLIENT: ....:.V•::st::•:.:P.::•c:..ifi..::·c..::d_ev..;:•..::lopm::._•_n_t _________________ PROJECT NO: _344_7_-s_o ______ _ PROJECT: Roosevelt QI, f.S: DATE: 04/10/19 PROJECT LOCATION: !-,,!!11!:.!cR~ooseve~~tt~. Ca=rls~b~ad~. C,::A~--------------::-:-==:------ CONTRACTOR: Verdugo construction PLANS BY: Gouvfsenglneor DATED: _____ _ BUILDING PERMIT;.::.:N.:::O:=.: C.;..:;;8~/.-j,2,-/fr2.0.,,...,,...,,/~'"'"---,,0,...,2..--,,3r/r-APPROVED BY: Carlsbad Pc201a-0019 DATED: ____ _ TYPE OF INSPECTION: .!A.:::•b,:::ar,.._ ______ SHEETS & DETAILS: LOCATION OF INSPECTION: _Soo=~be~lo!:w:..__ ________________________ _ The following items were observed and / or tested: Inspection and observation continues for SOG / FTG reinforcement for Building 112 Units 1 &2, building #3 units 3,4,S. blikting #1 units 8&9, Buliding #4 units 6,7, 10 and 11. Permits #CBAA2018-0223. CBAA2018-0224. CBAA2018-0225, CBRA2018-0226. CBAA2018-0227. CBRA2018-0230. CBRA2018-0231. CBAA2018-022B. CBAA2018-0229, CBAA2018-0232. CBAA2018·0233 Verified rebar is securely tied, with laps and clearance in place. #3@24" ocew, Cont (2)#4 TB, reinforcement for spread FTGs, All Pad FTGs verified, P3, P4, P5 and P7 per Pad Schedule. FTGs are debris free, Anchors in placed for S11I plates, strong wall and HOUs, Visqueen topped with 2N clean sand. General Notes, SN1, S01, exterior FTGs, founclatton plans, Holddowns schedule 2500 psi Concrete scheduled for 04/11/19@0700am TBD. Raguinaga@vestapaciflcdevelopment.com ~ Work observed during this inspection substantially complies to approved plans and specifications. 4 Hours: -----------SUPERVISOR: ~ PAGE ____ OF ____ _ D Not Complete. Work observed is still in progress and will require additional inspections. ~ Signature Desmond King S0#1169 /8132156 Print Name GEOTECHNICAL I ENVIRONMENTAL I MATERIALS