HomeMy WebLinkAbout2693 ROOSEVELT ST; ; CBRA2018-0230; PermitBuilding Permit Finaled Ccityof Carlsbad Residential Associated Permit Print Date: 12/07/2020 Permit No: CBRA2018-0230 Job Address: 2693 ROOSEVELT ST, CARLSBAD, CA 92008 Permit Type: BLDG-Associated Permit Residential Work Class: Parcel#: 2031013808 Track#: Valuation: $267,769.30 Lot#: Occupancy Group: #of Dwelling Units: 1 Project#: Plan#: Bedrooms: 3 Construction Type: Condo CT140007 8 DEV04098 Bathrooms: 3.0 Orig. Plan Check#: PC2018-0019 Plan Check#: Project Title: BEACHWALK AT ROOSEVELT Status: Applied: Issued: Fina led Close Out: Inspector: Final Inspection: Description: BEACHWALK AT ROOSEVELT: BLDG 1 // UNIT 8 //PLANA// 1,623 SF LIV// 434 SF GARAGE// 232 SF DECK Applicant: VESTA PROPERTIES GEOFF MCCOMIC 1818 lSTAVE SAN DIEGO, CA 92101-2662 (616) 481-3830 FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -outside CFD SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1-Medium BLDG SWPPP PLAN REVIEW FEE TIER 1-MEDIUM Total Fees: $12,246.37 Total Payments To Date: Building Division $12,246.37 Balance Due: 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov Closed -Finaled 11/15/2018 01/11/2019 MColl 12/07/2020 AMOUNT $1,222.40 $787.23 $66.00 $175.00 $92.00 $182.00 $9,371.93 $11.00 $34.81 $246.00 $58.00 $0.00 Page 1 of 1 PERMIT INSPECTION HISTORY for (CBRA2018-0230) Permit Type: BLDG-Associated Permit Residentil Application Date: 11/15/2018 Owner: Work Class: Condo Issue Date: 01/11/2019 Subdivision: Status: Closed -Finaled Expiration Date: 01/25/2021 Address: 2693 ROOSEVELT ST IVR Number: 15497 CARLSBAD, CA 92008 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Relnspectlon Inspection Date Start Date Status 01/1512020 01/1512020 BLDG-16 Insulation 116574-2020 Passed Michael Collins Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-17 Interior 116381-2020 Cancelled Michael Collins Relnspectlon Incomplete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 01/29/2020 01/29/2020 BLDG-17 lntorlor 117782-2020 Partial Pass Michael Collins Re Inspection Incomplete Leth/Drywall Checklist Item COMMENTS Passed BLOG-Building Deficiency Yes BLDG-Building Deficiency Drywall only Yes 02/13/2020 02/13/2020 BLDG-18 Exterior 119351.2020 Cancelled Michael Collins Relnspectlon Incomplete Leth/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Wrong code No BLDG-82 Drywall, 119503-2020 Passed Michael Collins Complete Exterior Lath, Gas Test Hot Mop Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-17 Interior Lath-Drywall Yes BLDG-18 Exterior Lath and Yes Drywall BLDG-23 Gas-Test-Repairs Yes 07/29/2020 07/29/2020 BLDG-11 134071-2020 Partial Pass Mlchael Collins Relnspectlon Incomplete Foundatlon/Ftg/Plers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Deck column footing/steel Yes 12/07/2020 12/07/2020 BLDG-Final Inspection 145552-2020 Passed Peter Dreibelbis Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes Monday, December 7, 2020 Page 3 of 3 PERMIT INSPECTION HISTORY for (CBRA2018-0230) Permit Type: BLDG-Associated Permit Residenti, Application Date: 11/15/2018 Owner: Work Class: Condo Issue Date: 01/11/2019 Subdivision: Status: Closed -Finaled Expiration Date: 01/25/2021 Address: 2693 ROOSEVELT ST IVR Number: 15497 CARLSBAD, CA 92008 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspectlon Inspection Date Start Date Status 06/28/2019 06/28/2019 BLDG-14 096110-2019 Failed Michael Collins Relnspectlon Incomplete Frame/Steel/Bolting/We ldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready, no super on site No BLDG-Building Deficiency Not ready No BLDG-Building Deficiency 2nd floor, floor sheathing and drag nailing Yes 07/02/2019 07/02/2019 BLDG-14 096493-2019 Partial Pass Michael Collins Relnspectlon Incomplete Frame/Steel/Bolting/We ldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No BLDG-Building Deficiency 3rd floor, floor sheathing and drag nailing Yes BLDG-Building Deficiency Not ready, no super on site No BLDG-Building Deficiency 2nd floor, floor sheathing and drag nailing Yes 08/30/2019 08/30/2019 BLDG-15 Roof/ReRoof 102691-2019 Partial Pass Michael Collins Reinspectlon Incomplete (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Sheathing/strap nailing only Yes 09/04/2019 09/0412019 BLDG-15 Rool/RoRoof 102990-2019 Partial Pass Chris Renfro Relnspectlon Incomplete (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Sheathing/strap nailing only Yes 10/21/2019 10/21/2019 BLDG-13 Shear 108105-2019 Failed Michael Collins Relnspectlon Incomplete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No 10/22/2019 10/22/2019 BLDG-13 Shear 108285-2019 Passed Michael Collins Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No BLDG-Building Deficiency Minor pick up Yes 01/10/2020 01/10/2020 BLDG-14 116025-2020 Passed Paul York Complete Frame/Steel/Bolting/We ldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready, no super on site Yes BLDG-Building Deficiency 2nd floor, floor sheathing and drag nailing Yes BLDG-Building Deficiency 3rd floor, floor sheathing and drag nailing Yes BLDG-Building Deficiency Not ready Yes Monday, December 7, 2020 Page 2 of 3 Building Permit Inspection History Finaled {city of Carlsbad PERMIT INSPECTION HISTORY for (CBRA2018-0230) Permit Type: BLDG-Associated Permit Residenlii Application Date: 11/15/2018 Owner: Work Class: Condo Issue Date: 01/11/2019 Subdivision: Status: Closed -Finaled Expiration Date: 01/25/2021 Address: 2693 ROOSEVELT ST IVR Number: 15497 CARLSBAD, CA 92008 Scheduled Actual Inspection Type Inspection No. ln$pectlon Primary Inspector Reinspectlon Inspection Date Start Date Status 02/26/2019 02/26/2019 BLDG-21 084644-2019 Passsd Michael Collins Complete Underground/Undorfio or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Wasle to POC only Yes 04/10/2019 04/10/2019 BLDG-11 088478-2019 Failed Michael Collins Relnspectlon Incomplete Foundatlon/Ftg/Ploni (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready, need electrical sub feed below No grade 04/15/2019 04/1512019 BLDG-11 088923-2019 Passed Michael Collins Complete Foundatlon/Ftg/Ploni (Robar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Ufer ok, see CBRA2018-0223 for conduit Yes notes BLDG-Building Deficiency Not ready, need electrical sub feed below No grade 06/07/2019 06/07/2019 BLDG-14 094155-2019 Failed Michael Collins Relnspectlon Incomplete Frame/SteoUBoltlng/We ldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No 06/10/2019 06/10/2019 BLDG-14 094246-2019 Partial Pass Michael Collins Relnspectlon Incomplete Frame/Steel/Bolting/We ldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency 2nd floor, floor sheathing and drag nailing Yes BLDG-Building Deficiency Not ready No 06/27/2019 06/27/2019 BLDG-14 095959-2019 Failed Michael Collins Relnspectlon Incomplete Frame/Steel/Bolting/We ldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No BLDG-Building Deficiency Not ready, no super on site No BLDG-Building Deficiency 2nd floor, floor sheathing and drag nailing Yes Monday, December 7, 2020 Page 1 of 3 IC:INGI ! IIUPECTION IIEllYICEII ! SPECIAL INSPECTION DAILY REPORT 3406 Texas Street San Diego, CA, 92104 619-261-9022 desmond@Kingisi.com www.Kingisi.com Special Inspection Reports shall be prepared on a Daily Basis. All Non..Compliant conditions must be reported IMMEDIATELY to the Superintendent. Each Inspection Report shall be completed and signed by the Special Inspector conducting the Inspection / Testing. Project Name: Roosevelt Apartments I Date: 10/17/19 Buildlnn Permit#: Build #1 Unit #8, CBRA2018-0230 Time Arrived: 7am Proiect Location: 2675 Roosevelt Street, vansoaa, VI"\, 92u08 Time Deoarted: Contractor: Vesta Pacific Development Architect: Sub-Contractor: UPF Engineer: Inspection / Material Description Sheathina, Anchors, nailina, straos, clips Samnles Ticket No#: AirTemo: I Concrete Temn : I @ Mins. lSlumo: I Approved Drawings: SN-1, General notes Work Inspected: Inspection and Observation continues for Interior and Exterior Shearwalls. Verified stamped sheathing secured in place; All nails·driven flush and staggered. Walls #2: 8d's@4/12, #3:3/12. #4 and #5:2/12. All Header, Straps, Blocking, A35 Clips and .Brackets per Shearwall Schedule. Holddown / anchors in place per plan schedule, engineers details. Hours: 4 Note : Partial interior inspectio_n,AU party_walls: After plumbing, electr1c:al, ga:;placemenland insulation will be palace and wall closed, Fire stop @10'0". City inspector will verify·prior to building1>eing rapped, Report emailed to Super Raul ~ WORK: (~ ~----- INSPECTED l~ANCE WITH THE REQUIREMENTS OF THE APPROVED DOCUMENTS. MATERIAL SAMPLING:-~ INSPECTED IN ACCORDANCE WITH T~EQ~S C/ OF THE APPROVED DOCUMENTS. LAB ID ATTACHED, SAMPLES SCHEDULED FOR PICK-UP THE WORK INSPECTED: Signature of Special Inspector: ~PIP NQT MfET ~ Print Name: Desmond King CERTIFICATION#: SD #1169, ICC #8132156 Signature of Superintendent ii; GeoTek, Inc. I S48 North Maple Street, Corona, California 92880 (9S1) 710-1160 Office (9S1) 710-1167 Fax www.geotekusa.com DAIL V INSPECTION REPORT CLIENT: Vesta pacific development PROJECT NO: _344_7_-s_o ______ _ PROJECT: :R::oo::se::v::ett:::... _ _.,..,,,,."3----------------DATE: 04/10/19 PROJECT LOCATION: .!.!l!'i~R"J~oo~seve~n~. C~•~rls!2ba~d~, C,:!A!.._ ______ ---:---------:::-:-=:::------ CONTRACTOR: v:.:or:..du=go:..con:.:..,,str::::.;,ucliOn,...·-n--------PLANS BY: Gouvis engineer DATED: _____ _ BUILDING PERMIT NO:C8.2112{)19,-t):{30 APPROVED BY: CartsbadPC2018--0Cl19 DATED: ____ _ TYPE OF INSPECTION: _:R_:::ebar~ _______ SHEETS & DETAILS: LOCATION OF INSPECTION: _See=~be~low~------------------------ fllt'ft!nowing items were observed and / or tested: Inspection and observation continues for SOG / FTG reinforcement for Building #2 Units 1 &2, building #3 units 3,4,5, buiktlng #1 units 8&9, Building #4 units 6,7,10 and 11. Permils #CBRA2018-0223, CBRA2018-0224, CBRA2018-0225, CBRA2018-0226, CBRA2018-0227, CBRA2018-0230, CBRA2018-0231, CBRA2018-0228, CBRA2018-0229, CBRA2018-0232, CBRA2018-0233 Verified rebar is securely tied, with laps and clearance In place. #3@24• ocew, Cont (2)#4 TB, reinforcement for spread FTGs, All Pad FTGs verified, P3, P4, PS and P7 per Pad Schedule. FTGs are debris free, Anchors in placed for sill plates, strong wall and HDUs, Visqueen topped with 2• clean sand. General Notes, SN1, S01, exterior FT Gs, foundation plans, Holddowns schedule 2500 psi Concn,te scheduled for 04/11119@0700orn TBO. Raguinaga@vestapacificdevelopment.com E] Work observed during this inspection substantially complies to approved plans and specifications. Hours: _4 __________ _ SUPERVISOR: ~,, PAGE ____ OF ____ _ ONot Complete. Work observed is still in progress and will require additional inspections. ~ Signature Desmond King S0#1169 /8132156 Print Name GEOTECHNICAL I ENVIRONMENTAL I MATERIALS