Loading...
HomeMy WebLinkAbout2215 PASEO SAUCEDAL; ; CB973906; Permitj 08J-1--1b'6f 02/.1.1/9~ 16:59 Page 1 of 1 B U I L D I N G lob Address: 2215 PASEO SAUCEDAL P E R M I T Suite: Permit Type: SINGLE FAMILY DWLNG -DETACHED Parcel No: 255-260-36-00 Lot#: 365 Permit No : CB973906 Project No : A9705033 Development No: DEV89110 Valuation : 223,541 Construction Type: VN ISSUED 12/08/97 02/11/98 JM Occupancy Group: Reference#: CT88-03 Status : Description: PLAN 3,SFD 2672 SF,GAR 636 SF Applied : : BALC 76 SF ,PORCH 44SF,K&B ,PHASE 1,VALL P Apr/Issue: Entered By : Appl/Ownr : KAUFMAN & BROAD 619 259-6000 12626 HIGH BLUFF DR STE 400 SAN DIEGO CA 92130 Plan Check Numbers > ORIG 972910 ,CB973754 *** Fees Required *** *** Fees Coll e cn~OllilUfJe@t),13 01 02 *** ------------------------------------------------------------C-ffiMi--·no~4:B3 Fees : 11,694 .83 Adjustments: .00 Total Fees: Fee description q:'otal C! edits: 'l'otal Payments: E}a lan ce Due: Units Fee/Unit .00 .00 11,694.83 Ext fee Data 4----~-------------------- Number of Bedrooms Number of Bath rooms Building Permit Plan Check . . . > . . . > 5 3.00 ..., Strong Motion Fee Enter "Y" to Auto Enter "Y" to Auto Payoff Fee for CF P..F .F . > A T. . . ) Enter LFM Fee (Zon s=6,1 1 ,1~) Enter "Y" for Plum ing Iss e Fe Each Plumbing Fixtu e or Tr Each Building Sewer Each Install/Repair Wat Each Water Heater and/o Gas Piping System Each Vacuum Breaker Enter "Y" for Electric Issue Fee Single Phase Per AMP > > > ~ > > > > Enter 'Y' for Mechanical Issue Fee> Install Furn/Ducts/Heat Pumps > Each Install Fireplace > Each Exhaust Fan > Each Install/Reloc Vent > 469,$.88 310.pO 125 2 1 3 2 7 , 0 15.00 7,00 7.00 7.00 7.00 .25 9.00 6.50 6.~o 4.50 5 .00 3.00 1074.00 698.00 22 .00 4068 .00 Y 540.00 Y 4698.83 310.00 20 .00 Y 105.00 15.00 7 .00 7.00 7 .00 14.00 10.00 Y 31.25 15.00 Y 18.00 6.50 19 .50 9.00 I FINAL APPFH'."lVAL I INS~ -c);\ I E t;1r/4L CLEARANC E t: ~ 'c. S\\3\s'U«> CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 CITY OF CARLSBAD INSPECTION REQUEST FOR 08/13/98 3,SFD 2672 SF,GAR 636 SF PERMIT# CB973906 DESCRIPTION: PLAN BALC 76 SF,PORCH 44SF,K&B,PHASE l,VALL P INSPECTOR AREA TP PLANCK# ORIG 972 OCC GRP TYPE: SFD JOB ADDRESS: 2215 APPLICANT: KAUFMAN CONTRACTOR: OWNER: REMARKS: C/MIKE SPECIAL INSTRUCT: TOTAL TIME: LVL DESCRIPTION PASEO SAUCEDAL & BROAD CD 19 29 39 49 ST Final Structural PL Final Plumbing EL Final Electrical ME Final Mechanical --- STE: CONSTR. TYPE VN LOT: 365 PHONE: 619 259-6000 PHONE: PHONE: /} INSPECTOR --J.~=--'-· ______ _ ACT COMMENTS ***** INSPECTION HISTORY ***** DATE DESCRIPTION ACT INSP COMMENTS 072898 Final Combo NR TP FINAL ROUTING 071698 Final Electrical AP TP 061798 Interior Lath/Drywall AP TP 061798 Exterior Lath/Drywall AP TP 061598 Interior Lath/Drywall NR NF 061598 Exterior Lath/Drywall NR NF 061198 Insulation AP TP 061198 Shower Pan/Roman Tubs AP TP 061098 Rough Combo AP TP 060998 Rough Combo AP TP 052998 Roof Sheathing/Ext Shear AP PD 052898 Roof Sheathing/Ext Shear NR PD 052198 Sewer/Water Service AP TP 040698 Underground Combo AP TP 040198 Underground Combo NR TP 033098 Underground Combo NR TP RAIN 032798 Underground Combo NR TP 032698 Underground Combo NR TP 031398 Underground/Under Floor AP TP 031298 Underground/Under Floor NR TP FINAL'1BUILDING INSPECTION ------·---------) DEPT: BUILDING (ENGINEERING FIRE PLANNING CMWD ST LITE PLAN CHECK#: CB~73906 DATE: 07/24/98 PERMIT#: CB973906 PERMIT TYPE: SFD PROJECT NAME: PLAN 3,SFD 2672 SF,GAR 636 SF BALC 76 SF,PORCH 44SF,K&B,PHASE l,VALL P ADDRESS: 2215 PASEO SAUCEDAL Lot# 365 CONTACT PERSON/PHONE#: C/MIKE/436-6516 SEWER DIST: LC WATER DIST: 0 ---------------------------------------------=-----========-================= INSPECTED f?✓-::? DATE ✓ BY: INSPECTED: 7-27-C/S' APPROVED DISAPPROVED INSPECTED ;:JP. DATE .fi_ BY: INSPECTED: 7-:/V '7 i APPROVED DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED -------=----------------------===-------======--======-----==---------==----- DEPT: BUILDING FINA~t,ur~ING INSPECTION ENGINEERING ~~/ 1 PLANNING CMWD ST LITE PLAN CHECK#: CB973906 DATE: 07/24/98 PERMIT#: CB973906 PERMIT TYPE: SFD PROJECT NAME: PLAN 3,SFD 2672 SF,GAR 636 SF BALC 76 SF,PORCH 44SF,K&B,PHASE 1,VALL P ADDRESS: 2215 PASEO SAUCEDAL CONTACT PERSON/PHONE#: C/MIKE/436-6516 SEWER DIST: LC WATER DIST: 0 INSPECTED BY: INSPECTED BY: COMMENTS: DATE INSPECTED: DATE INSPECTED: DATE INSPECTED: 9il~/'.iI Lot# 365 APPROVED ,(___ APPROVED APPROVED ' ' DISAPPROVED DISAPPROVED DISAPPROVED FINAL BUILDING INSPEC'IION DEPT: BUILDING ENGINEERING PLAN CHECK#: CB973906 PERMIT#: CB973906 FIRE PROJECT NAME: PLAN 3,SFD 2672 SF,GAR 636 SF CMWD BALC 76 SF,PORCH 44SF,K&B,PHASE l,VALL P ST LITE DATE: 07/24/98 PERMIT TYPE: SFD ADDRESS: 2215 PASEO SAUCEDAL Lot# 365 CONTACT PERSON/PHONE#: C/MIKE/436-6516 SEWER DIST: LC WATER DIST: 0 =====================-========================-==-=========================== INSPECTED BY: Lo/0 INSPECTED BY: INSPECTED BY: COMMENTS: DATE INSPECTED: DATE INSPECTED: DATE INSPECTED: S·0> ·S:S APPROVED / DISAPPROVED APPROVED DISAPPROVED APPROVED DISAPPROVED FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING FIRE PLANNING CMWD ST LITE PLAN CHECK#: CB973906 DATE: 07/24/98 PERMIT#: CB973906 PERMIT TYPE: SFD PROJECT NAME: PLAN 3,SFD 2672 SF,GAR 636 SF BALC 76 SF,PORCH 44SF,K&B,PHASE 1,VALL P ADDRESS: 2215 PASEO SAUCEDAL Lot# 365 CONTACT PERSON/PHONE#: C/MIKE/436-6516 SEWER DIST: LC WATER DIST: 0 INSPECTED BY: ~ DATE --, ,,,«J ,,-·. iJ J\ INSPECTED: ~ APPROVEf15 -\.~DISAPPROVE~ INSPECTED BY: INSPECTED BY: COMMENTS: DATE INSPECTED: DATE INSPECTED: APPROVED DISAPPROVED APPROVED DISAPPROVED Mike Cravens VANDORPE CHOU ASSOCIATES, INC. CONSULTING ENGINEERS 295 N. Rampart Street, Suite A Orange, CA 92868 Tel: (714) 978-9780 Fax (714) 978-9926 Kaufman & Broad San Diego Div. I 2626 High Bluff Dr. Ste 400 San Diego, CA 92130 Subject: Villages at La Costa 'P' Plan #3, Lot #365 Ur'r" Jf)AJ,-t, ,J"AVel~~'- Dear Mike, Since 1979: Facility Planners Code Consultants Swctural Engineers Fire Protection Engineers June 9, 1998 We understand that fixes forHD6A hold downs were made at the rear of the subject plan without special inspection and the building inspector is requiring pull tests to be conducted. The pull test should be for twice the capacity of the hold down, for a total of 10,200#. If you have any questions, please call Mike Burica of our office. Very truly yours, Nrl. S 003518 MB E;ql. 3-31-00 f:ljobfileslK&BIKB 1348\Ficld2.wpd SOUTHERN CALIFORNIA SOIL & TESTING, INC. 6280 RIVERDALE STREET, P.O. BOX 600627, SAN DIEGO, CA92160-0627, Phone (619) 280-4321, FAX (619) 280-4717 FIELD INSPECTION REPORT FOR: □ REINFORCED CONCRE~ REINFORCED MASONRY □ WELDING □ FIREPROOFING □P.r.coNcRErE , EPoxv ANcHoRs □H.s.eOLr1NG 'ii:J/!yll f:,sT PROJECTTITLE R4--rt<. 12,(.JC,~ SCS& T FILE No. ,,.'• r PROJECT LOCATION''2,_'2 / ) p ,4 ', .. { ~ ,~ J t (••I .JAv t,1 .«:J ---PERMIT No . '17·3q ~1 C:, I PLAN FILE No. ARCHITECT ENGINEER GENERAL CONTRACTOR J;::';9,_,,..,,,,,., f-l';r,,,.-J -,/ SUB CONTRACTOR MATERIAL CLASSIFICATION DATE DESCRIPTION OF WORK INSPECTED (.. -I I 4 k" A , 11 p ,.,u,._,\ I!) I-~ :; I 7 f Af lb LL ,, ,. < ""t. d' 7(:7 ~.t y J ~_,l ,,.... "1LJ(_(... J;. ·r )I £ /J 0/,:'·/ r C\ BoLJ C'u.•/1 fflu!Ts • , V • ~ .J1 A.,,L t..,, ( L,_,, 14 '.i ( '"2.11 /1;;1'' ,4 /l Tl·l'•'r1.{ /+ r·i C' /J. iJM 6t,lh ,,~ Y7 f!vl Juu• NJ . ,?''ff Ll11v> e. /Jo/if «;,J.-I A, f2-< fl. I';:. l!)n '..,,,.,( C-iL..45< di$"" -,,ri~,I, .;S"/.1/)1,1 ,,, i-, tL~ .14-,,. -·B,~!Ts . I 1-kJ. t.J I C,?, 7-(!; ~ I~ s ../ // ,, . t LV{,,.,.~ A, N LJ,R,,. ' </ c.l ~ -1. rrl ;,.-1(,,1"1'.,..a. . V (_~;· I' ,(! -1".------....f k,/ki1ft;...- I hereby certify that I have lnapected the above reported J-Lu_',rr _, J J ..,/..L f.:,"2..{° work. Unleu noted otherwise, the work inspected Is to ,// ! ._,, -'s.. -, the bast of my knowledge in compliance with the approved '-' INSPECTORS SIGNATURE REGISTRATION No. plans, specifications and appllcable sections of the governing building Jaw,. .. ~UPERINTENDANTS SIGNATURE DATE SOUTHERN CALIFORNIA SOIL AND TESTING, INC. 6280 RIVERDALE STREET, P. 0. Box 600627, SAN DIEGO, CA 92160 (619) 280-4321 Concrete Compressive Strength Test Report File Number: Project Title: Project Location: Architect: Engineer: Contractor: Location In Structure: Material Supplier: Mix Designation: Admixture(s): 9812070 Parkridge -Village "P" 2215 Paseo Sauceda! Kaufman & Broad J.L. Davidson Kaufman & Broad Lot 365 -slab-on-grade Superior Ready Mix 35P Pozzutec Time In Mixer (Minutes): 67 Slump, Inches: 3-112 Truck Number: Samples Fabricated By: Laboratory Number: Mark: 365 Date Made: Date Received Date Tested Diameter, Inches Area, Square Inches Maximum Load, Pounds Compressive Strength, psi Age Tested, Days 605 RJL Required 28 Day Strength, psi 1556 04-07-98 04-09-98 04-17-98 6.00 28.27 89,000 3,150 10 2,500 Ticket Number: 176392 Samples Tested By: NH 1557 1558 05-05-98 05-05-98 114,250 116,750 4,040 4,130 28 28 Permit No: 8973905 Plan File No: CC Temp: Air Temp: Air Content: 0 0 % Specimen sampling, transportation and compressive strength testing were performed by this agency in accordance with the applicable ASTM standards. This agency makes no other warranties express or implied. Distribution: (2) Kaufman & Broad (1) City of Carlsbad 04-0?c 515198 George Gavit, RCE #56564