HomeMy WebLinkAboutPRE 2020-0026; FRONT PORCH, SUMMER HOUSE AT CARLSBAD BY THE SEA; Admin Decision LetterOctober 14, 2020
Jo Johnson
2855 Carlsbad Boulevard
Carlsbad, CA 92008
Ccityof
Carlsbad
SUBJECT: PRE 2020-0026 (DEV2020-0217) -FRONT PORCH, SUMMER HOUSE AT CARLSBAD BY
THE SEA
APN: 203-153-01-00/203-143-02-00
Thank you for submitting a preliminary review to consolidate two lots to construct a mixed-use
development that includes underground parking, approximately 4,600 square feet of commercial space,
16 professional care units, 12 independent living units and a roof top deck proposed at 2729 Carlsbad
Boulevard. The project site, which comprises two lots totaling 22,500 square feet, is currently developed
with three commercial buildings.
In response to your application, the Planning Division has prepared this comment letter. Please note that
the purpose of a preliminary review is to provide you with direction and comments on the overall concept
of your project. This preliminary review does not represent an in-depth analysis of your project. It is
intended to give you feedback on critical issues based upon the information provided in your submittal.
This review is based upon the plans, policies. and standards in effect as of the date of this review. Please
be aware that at the time of a formal application submittal. new plans, policies, and standards may be
in effect and additional issues of concern may be raised through a more specific and detailed review.
Planning:
General
1. General Plan and zoning designations for the property are as follows:
a. General Plan: Village (V)
b. Zoning: Village -Barrio (V -R), Hospitality (HOSP) District
c. The property is in the non-appealable area of the Coastal Zone. The Coastal land use designation
and zone are the same as the General Plan and Zoning above.
2. The project requires the following permits and the City Council will be the decision-making authority:
a. Site Development Plan (SDP)-to construct a new building over 5,000 square feet in size.
b. Conditional Use Permit (CUP)-to permit the professional care facility use.
c. Coastal Development Permit (CDP) -for the lot consolidation and development of the mixed-use
structure.
Community Development Department
Planning Division I 1635 Faraday Avenue Carlsbad, CA 92008-7314 I 760-602-4600 I 760-602-8560 f I www.carlsbadca.gov
PRE 2020-0026 (DEVZ020-0217) -FRONT PORCH, SUMMER HOUSE AT CARLSBAD BY THE SEA
October 14, 2020
Pa e 2
3. Site Planning. Pursuant to Section 2.6.l(A) of the Village & Barrio Master Plan (VBMP), the project is
permitted to be designed with a maximum of one vehicular access point from a public street. In
addition, the driveway apron shall not exceed a width of 20 feet. The preliminary design appears to
ccii:npl{~ith this requirement by providing one vehicular entry to the subterranean parking garage
frcim 'Beech Street.
4. Walls and Fences. Plans submitted with the formal application must provide wall and fence details
such as materials and height dimensions. All proposed walls must comply with the provisions
contained in Section 2.6.l(D) of the VBMP.
5. Window Glazing. In accordance with Section 2.6.3(A) of the VBMP, a minimum of 45 percent of glazing
is required for the ground floor fa~ade of commercial uses that are adjacent to a public street. The
fa~ade is measured from the plate height to the finished floor. Glazing must be transparent, and any
opaque, reflective or dark tinted glass is not permitted. In addition, the bottom of any window display
shall not be more than 3.5 feet above an adjacent sidewalk. Elevation plans submitted with the formal
application must provide full dimensions of all window areas and must show compliance with the
minimum percent of glazing, the glazing transparency detail, and dimensions to the bottom of any
non-transparent window display, which cannot exceed 3.5 feet.
6. Good Neighbor Requirements. Pursuant to Section 2.6.4(A) of the VBMP, the project is subject to the
Good Neighbor Requirements which include and are not limited to maintaining building grounds,
parking, pedestrian areas and landscaping in a neat and orderly manner at all times; providing
screening for loading areas; locating noise generating equipment away from any residential uses; and
commercial uses with residential units attached shall provide ventilation systems to prevent odors
from adversely affecting residential units. Please submit a project description with the formal
application that explains compliance with the Good Neighbor Requirements and reference Section
2.6.4(A) of the VBMP for the comprehensive list of provisions.
7. Parking. The preliminary plans do not include enough information for staff to confirm if the second
floor units qualify as professional care, housing for seniors, or multi-family units. The formal
application will need to specifically describe the use and declare the occupancy type for these units.
In accordance with Section 2.6.6(A) of the VBMP the following parking ratios are required for each
type of use:
a. Retail. One space per 415 square feet of gross floor area dedicated to retail use. Other commercial
uses have different parking ratios that are found in Section 2.6.6 of the VBMP, Table 2-3.
b. Professional Care. 0.45 space per e.very bed if the second floor is determined to be professional
care units, which are classified as commercial dwelling units.
c. Independent Living/Senior Housing. 1.5 spaces per unit if the second floor is determined to be
residential units. The city considers the offices shown on the floor plan in one-bedroom units to
be bedrooms, so those units require parking as two-bedroom units. If the use is determined to be
housing for seniors, then one additional parking space will be required for an onsite manager's
unit when/if provided.
Per Carlsbad Municipal Code (CMC) Section 21.44.050, a standard parking space must be a minimum
of 170 square feet with a minimum width of 8.5 feet. Plans submitted with the application must
provide a parking matrix with accurate required parking ratios for each use. In addition, the floor plan
PRE 2020-0026 (DEV2020-0217}-FRONT PORCH, SUMMER HOUSE AT CARLSBAD BY THE SEA
October 14, 2020
Pa e 3
of the parking area must provide full dimensions of a standard parking stall in tompliance with CMC
Section 21.44.050.
8. Excess Dwelling Unit Bank. If the second floor is determined to be commercial dwelling units, then the
project will not be subject to residentlal density and no allocations from the Excess Dwelling Unit Bank
will be required. Alternatively, if the second floor is determined to be residential dwelling units, then
residential density will apply and an allocation of units from the Excess Dwelling Unit Bank will be
required for all 12 units ..
9. lnclusionary Housing. If the second floor is determined to be residential dwelling units, then the
project shall comply with Carlsbad Municipal Code Chapter 21.85, lnclusionary Housing. The project
must provide 15 percent of the total residential dwelling units to be affordable to low income
households.
10. Rear Setback. Per Section 2.7.3(A), parcels fronting Carlsbad Boulevard between Beech Avenue and
Carlsbad Village Drive must maintain a five-foot rear yard setback. The site plan submitted with the
formal application must provide fully dimensioned setbacks.
11. Lot Coverage. In accordance with Section 2.7.3(C) of the VBMP, the maximum lot coverage is 80
percent. Lot coverage includes the perimeter of the underground parking area, exterior structures
such as stairs, permanent structural elements protruding from a building such as overhanging
balconies, windows and stories that overhang a ground level. Excluded from lot coverage are roof
eaves extending less than 30 inches from the face of the building, awnings, and structures under 30
inches in height. The plans submitted with the application must include a breakdown of the lot
coverage calculations.
12. Open Space. Per Section 2.7.3(E), a minimum of 20 percent of the property must be maintained as
open space. Open space may be dedicated to landscape planters; open space pockets, roof gardens,
patios, balconies, or outdoor eating areas. Plans submitted with the application for review must show
fully dimensioned open space areas.
13. Service and Delivery Areas. Loading areas must be fully screened from public view and located away
from the front property line. The plans submitted with the application must identify areas for service
arid delivery for the commercial and professional care uses.
14. Building Height. Per Section 2.7.3(G) of the VBMP, the maximum building height in the Hospitality
District of the VBMP is limited to 45 feet and four stories. The minimum ground floor wall plate height
for buildings fronting Carlsbad Boulevard is 14 feet, measured from the finished floor to the top plate
of the ground floor. Where there is no top plate, the measurement is taken to the bottom of the floor
structure of the second floor. Please provide fully dimensioned section drawings on the plans
submitted with the formal application showing compliance with the minimum ground floor wall plate
height. In addition, provide fully dimensioned elevation plans showing th.e height taken from the
existing grade to the highest peak of the building.
15. Building Massing. Section 2.7 .3(H) of the VBMP requires a building fa~ade visible from any public
street to provide a minimum five-foot variation in wall plane and a change in roofline every 50 feet in
length. Elevation drawings provided with the application must provide dimensions of the wall plane
breaks and roof line changes.
PRE 2020-0026 (DEV2020-0217)-FRONT PORCH, SUMMER HOUSE AT CARLSBAD BY THE SEA
October 14, 2020
Pa e 4
16. Ground Floor Street Frontage. New ground floor street frontage commercial uses must occupy more
than one-half of the ground floor area and must span at least 80 percent of each building frontage
along Carlsbad Boulevard and Beech Avenue. In addition, due to the location of the project, Section
2.7.3 of the VBMP requires the ground floor street frontage uses must also have a minimum average
depth of 25 feet. Floor plans submitted for review with the formal application must be fully
dimensioned to demonstrate compliance with the ground floor street frontage requirements. If the
commercial component will not meet the required 80 percent building frontage and the minimum
average depth of 25 feet, a standards modification must be requested and the applicant must prove
it is necessary to achieve one or more of the limited purposes outlined in subsection B of Section 2.6.7
of the VBMP. In addition, to grant a standards modification, the City Council must make the four
required findings listed in subsection C of Section 2.6.7 of the VBMP.
17. Design Guidelines. The project is subject to compliance with the Design Guidelines contained within
Sections 2.8.2 and 2.8.3 of the VBMP. A project description submitted with the application should
explain how the site layout, building form and massing, and other design guideline provisions are met
with the proposed design.
18. Noise Study. The project site is located within 500 feet from the existing and future 65-70 CNEL transit
noise contours per the General Plan. To analyze the project's compliance with the city's Noise
Guidelines Manual and the Noise Element of the General Plan, please submit a Noise Analysis
prepared by a registered acoustician at formal application submittal for the proposed project. If
certain building features (i.e., STC-rated windows, etc.) are required to comply with the interior noise
requirements, please include the details on the plans. The Noise Guidelines Manual can be found on
the city's website at the following address:
https://www.carlsbadca.gov/civicax/filebank/blobdload.aspx?Blob1D-24094
19. New requirements related to the city's goals to reduce greenhouse gas (GHG) emissions will likely
impact development requirements of this project. A formal application submittal will need to include
a completed Climate Action Plan Checklist (Form P-30) to determine what requirements will apply to
the project. New GHG reduction requirements are related to energy efficiency, photovoltaic, electric
vehicle charging, water heating and traffic demand management requirements, as set forth in the
California Green Building Standards Code and in Carlsbad Municipal Code Chapters 18.21, 18.30 and
18.51 which is available on the city's website at the following address:
http://www.qcode.us/codes/car1sbad/view.php?topic-18&frames-on
To the extent that new GHG reduction requirements are in effect at the time of application for grading
or building permits, the project will be required to comply with the effective requirements eveA if
different than what is proposed in the project's planning approvals. GHG reduction requirements may
impact, but are not limited to, site design and local building code requirements. If incorporating new
GHG reduction requirements results in substantial modifications to the project after planning
approvals are obtained, then prior to issuance of grading or building permits, the applicant may be
required to submit and receive approval of a Consistency Determination or an Amendment
application for the project through the Planning Division.
All necessary application forms, submittal requirements, and fee information are available at the Planning
counter located in the Faraday Building at 1635 Faraday Avenue or online at
,·
PRE 2020-0026 (DEV2020-0217)-FRONT PORCH, SUMMER HOUSE AT CARLSBAD BY THE SEA
October 14, 2020
Pa e 5
http://www.carlsbadca.gov/services/depts/planning/default.asp. You may also access the General Plan
Land Use Element and the Zoning Ordinance online at the website address shown; select Department
Listing; select Planning Home Page. Please review all information carefully before submitting.
Land Development Engineering:
1. No civil plans/preliminary grading plans were provided as part of this review. Note that a complete
project design is needed to conduct a thorough and complete review of the project. Additional items
of concern maybe identified upon formal project application submittal.
2. Submit an Adjustment Plat application to consolidate the two existing lots into one lot.
3. Determine the project's Average Daily Traffic (ADT) and indicate on the site plan. Based on the
preliminary site plan, the project's ADT exceeds the 110 ADT threshold. A traffic impact analysis is
required to address potential traffic impacts associated with this development. The traffic analysis
shall be prepared in accordance the new traffic impact analysis (TIA) guidelines available on the city
website at:
http://www.carlsbadca.gov/civicax/fi1ebank/blobdload.aspx?Blob1D=22758
Prior to initiating a TIA, a scope of work shall be submitted, reviewed, and approved by City staff. A
Scoping Agreement with City of Carlsbad shall be filed prior to initiating the Transportation Impact
Analysis report (refer to Appendix A of the guidelines). The Scoping Agreement ensures an
understanding of the level of detail and the assumptions required for the analysis.
4. Determine the total number of employee ADT expected for the project and indicate on the site plan.
Provide supporting information/narrative showing how the total employee ADT is
calculated. Distinguish part time and fulltime employees and provide anticipated shift schedules. If
the total employee ADT exceeds the 110 ADT threshold, the project is required to submit a
Transportation Demand Management (TDM) plan in accordance with the Transportation
Management Demand Handbook available in the City website at:
https://www.carlsbadca.gov/civicax/fi1ebank/blobdload.aspx?Blob1D=39379
5. Complete a Stormwater Standards Questionnaire, Form E-34, to determine the storm water
requirements for the proposed project. The questionnaire is available in the city website at:
http://www.carlsbadca.gov/civicax/fi1ebank/blobdload.aspx?Blob1D=227l1
Note that the total impervious area includes new and replaced existing impervious area. Indicate the
total impervious area on the site plan.
6. Based on the preliminary site plan, the proposed impervious area exceeds the 5,000 sq. ft. threshold,
and the project qualifies as a 'Priority Development Project' (PDP). A Storm Water Quality
Management Plan (SWQMP) is required. The SWQMP shall be prepared in accordance with the City
of Carlsbad BMP Manual (latest version). Use the City of Carlsbad SWQMP template for priority
development project (Form E-35) available in the City website at:
PRE 2020-0026 (DEV2020-0217)-FRONT PORCH, SUMMER HOUSE AT CARLSBAD BY THE SEA
October 14, 2020
Pa e 6
http://www.carlsbadca.gov/civicax/filebank/blobdload.aspx?Blob1D=22712
Note that the project is not exempt from hydromodification requirement. The project must provide
both pollutant control BMPs and hydromodification facility designed in accordance with the City of
Carlsbad BMP manual.
7. Ensure that all storm water run-offs are routed to treatment BMPs and hydromodification facilities
prior to discharge into the public street or prior to connecting into the public storm drain system. The
preliminary site plan does not identify locations of any stormwater BMPs. It appears that there is no
area provided for stormwater BMPs on the ground level. The proposed building footprint may need
to be reduced to accommodate stormwater BMPs on the ground level.
The proposed roof garden can be considered pervious surface to reduce the total impervious area.
· The project may also use pervious pavement to reduce the total impervious area, reduce the DCV and
consequently reduce the footprint of the pollutant control BMP required for this project. The pervious
pavement shall be designed in accordance with SD-6B fact sheet, Appendix E.S of the City of Carlsbad
BMP Manual. It is considered site design BMP, designed as self-retaining BMP, primarily for direct
rainfall only (not designed to treat additional impervious area).
Note that a Proprietary pollutant control BMP such as Modular Wetland System (MWS) is only
acceptable where site-specific documentation demonstrates that the use of a larger footprint BMPs
would be infeasible (see Section F.2.2 of the City of Carlsbad BMP Manual).
8. Show cross-sections and details of all proposed biofiltration basins, including overflow and outlet
structures on the preliminary grading plans. The outlet structure must be designed to convey
stormwater runoff from larger storm events up to 100-year storm event.
9. Submit a preliminary hydrology report to address site drainage and to mitigate any increase in 100-
year storm event flow due to the proposed development. Show that the post-development flow is
equal to or less than the pre-development flow at the point of compliance (POC). No cross-lot drainage
is allowed.
10. Submit a preliminary Geotechnical Study that provides recommendations for the proposed
development including design recommendations for any proposed pollutant control BMP and
hydromodification facility proposed for this project.
11. Show the property boundary data including bearings and distances.
12. Provide a preliminary title report dated within 6 months of the discretionary application date. Show
and label on the plans, all easements and encumbrances identified in schedule B of the said report.
13. Indicate the volume of grading (cut, fill, import, export, remedial) proposed for the project in cubic
yards. A grading permit will be required for this project.
14. Provide multiple cross-section to illustrate differences in grade.
15. Show top of wall and top of footing elevations of the any proposed retaining walls including the
basement walls. Show shoring walls, or the limits-of 1:1 temporary back cut needed for retaining wall
PRE ~020-0026 (DE\/2020-0217)-FRONT PORCH, SUMMER HOUSE AT CARLSBAD BY THE SEA
October 14, 2020
Pa e 7
construction. Obtain permission to grade from adjacent property owner if grading extends beyond
property lines.
16. Show the existing and proposed contour lines, spot elevations, high point, low points onsite, on the
adjacent streets and on the adjacent properties within 25 feet beyond the project boundary.
17. Show driveway profile. Ensure that the high point is located at the right-of-way line as shown in the
San Diego Regional Standard Drawing (SDRSD) G-14A. Ensure that no street drainage street drainage
can potentially flow into the proposed basement during major storm events.
18. Clearly show the proposed on-site drainage pattern on the preliminary grading plans. Show high
points, flowline elevations, percent grades and show the directions lot drainage using drainage
arrows.
19. NGVD 29 datum for vertical control per city Engineering Standard Volume 1, Chapter 2.
20. Indicate the sewer demand in equivalent dwelling units (EDU), potable water demand in gallons per
minute (GPD) on the site plan.
21. Show the locations, identify and reference city approved drawing for all existing utilities including
water lines and sewer lines within Beech Street and Carlsbad Blvd. The existing utilities include the
following: Beech Street: 12" PVC and 8" PVC sewer lines per approved drawing DWG 460-5 and 6"
ACP water line per DWG 195-3; Carlsbad Blvd: 8" VCP sewer line per DWG 118-9 and 8" ACP water
line per DWG 159-9.
22. Show all existing and proposed services including, potable water service, irrigation water service,
fire water service, fire hydrants and sewer laterals. Show the locations water meters and backflow
preventers. Note that backflow preventers are private and shall be located outside the public right-
of-way.
23. On the site plan, show all existing surface improvements for Beech Street and Carlsbad Blvd. at the
project frontage including street pavement, curb and gutter, sidewalk, inlets, street lights, vaults,
transformers, etc. and reference the city approved drawing. Clearly show and indicate the width of
existing R/W and width of existing street pavement (curb-to-curb).
24. Provide typical street cross-section for Beech Street and Carlsbad Blvd. at the project frontage.
25. Meet with the Fire Department to identify the necessary fire protection measures required for this
project (access, fire hydrants, sprinkler system, etc.).
26. Show location of all existing and proposed fire hydrants within 300 feet of the project boundary.
27. Provide a 5-foot wide (minimum) back-up space for the basement parking stall adjacent to northwest
basement wall.
28. This preliminary review does not constitute a complete review of the proposed project and additional
items of concern may be identified upon formal project application submittal
PRE 2020-0026 (DEV2020-0217) -FRONT PORCH, SUMMER HOUSE AT CARLSBAD BY THE SEA
October 14, 2020
Pa e 8 ·
Building:
1. The design needs to consider the following:
•
a. Climate Action Plan {CAP) compliance for new construction of residential and non-residential
structures.
b. Roof deck egress width;
c. Accessible parking;
d. EV capable and installed parking as required per CAP;
e. Accessible units and common areas on the second level per California Building Code 11A.
1. NFPA 13 Fire Sprinklers and NFPA 72 Fire Alarms are required for the project.
2. The facility will be a State Fire Marshal regulated facility.
3. Please contact Darcy Davidson, Assistant Fire Marshal, for more information regarding any required
fire protection systems at darcy.davidson@carlsbadca.gov.
If you would like to schedule a meeting to discuss this letter with the commenting departments, please
contact Jessica Bui at the number below. You may also contact each department individually as follows:
• Planning Division: Jessica Bui, Associate Planner, at {760) 602-4631
• Land Development Engineering: Tecla Levy, Associate Engineer, at {760) 602-2733
• Building Division: Jason Pasiut, Building and Code Enforcement Manager, at {760) 602-2788
• Fire Department: Darcy Davidson, Assistant Fire Marshal, at darcy.davidson@carlsbadca.gov
Sincerely,
~11«
DON NEU, AICP
City Planner
DN:JB:cf
c: Father Doran, 2775 Carlsbad Boulevard, Carlsbad, CA 92008
Diego Lastres, 1030 G Street, San Diego, CA 92101
Tecla Levy, Project Engineer
Fire Prevention
HPRM/File Copy
Data Entry