HomeMy WebLinkAboutPRE 2020-0003; REED FAMILY RESIDENCE; Admin Decision LetterMarch 2, 2020
Brian Enright
3472 Meade Ave
San Diego, CA 92116
FILE
SUBJECT: PRE 2020-0003 (DEV2020-0011) -REED FAMILY RESIDENCE
APN: 156-231-21-00
{"Cityof
Carlsbad
Thank you for submitting a preliminary review for a new single-family residence project proposed at 1375
Buena Vista Way. The project site, a 17,336-square-foot lot, currently is developed with a single-family
home and an accessory dwelling unit.
In response to your application, the Planning Division has prepared this comment letter. Please note that
the purpose of a preliminary review is to provide you with direction and comments on the overall concept
of your project. This preliminary review does not represent an in-depth analysis of your project. It is
intended to give you feedback on critical issues based upon the information provided in your submittal.
This review is based upon the plans, policies, and standards in effect as of the date of this review. Please
be aware that at the time of a formal application submittal, new plans, policies, and standards may be
in effect and additional issues of concern may be raised through a more specific and detailed review.
Planning:
General
1. General Plan and zoning designations for the property are as follows:
a. General Plan: R-4 Residential, 0-4 units/ac. Growth Management Control Point of 3.2 units/ac.
b. Zoning: R-1 One-Family Residential
2. The project requires the following permits:
a. Grading Permit (subject to proposed cut/fill volumes)
b. Building Permit
3. As described in the scope of work, this preliminary review application is for the construction of a new
4,110-square-foot residence with an attached garage, a detached 640-square-foot accessory dwelling
unit, and an additional detached garage with a workshop above. The Carlsbad Municipal Code (CMC)
permits single-family dwellings within the R-1 zone. Therefore, staff supports the proposed residential
use subject to compliance with all applicable CMC standards, including but not limited to Sections
21.10 (R-1 One-Family Residential Zone) and 21.44 (Parking). Specifically, staff has concerns with the
following:
a. Pursuant to CMC Section 21.04.061, the trellises, carports, and patio covers need to be included
in the proposed lot coverage calculation.
Community Development Department
Planning Division I 1635 Faraday Avenue Carlsbad, CA 92008-73141760-602-4600 I 760-602-8560 f I www.carlsbadca.gov
PRE 2020-0003 {DEV2020-0011) -REED FAMILY RESIDENCE
March 2, 2020
Page 2
b. Pursuant to CMC Section 21.10.050, the maximum building height for the single-family residence
with a roof pitch that is less than 3:12 is 24 feet.
c. The accessory dwelling unit is subject to CMC Section 21.10.030 and recent state laws (SB 13, AB
68, AB 587, AB 670, AB 671, and AB 881). Detached accessory dwelling units may not exceed a
height of 16 feet, unless it is above a garage, where the zone height limit applies.
d. Pursuant to CMC Section 21.10.080(A)(l)(c), the distance between buildings used for human
habitation and accessory buildings shall be not less than ten feet.
e. Pursuant to CMC Section 21.10.080{A)(l){d)(v), accessory structures that do not contain an
accessory dwelling unit are limited to one story. The proposed workshop above the detached
garage is therefore not permitted. Additionally, please clarify the connection between the main
dwelling and the front garage. The office above the front garage is only permitted if the structure
is fully attached to the main dwelling.
f. Pursuant to CMC Section 21.10.080(A)(l)(d)(vi), accessory structures that. do not contain an
accessory dwelling unit and have a roof pitch that is less than 3:12 shall not exceed a height of ten
feet. If the roof pitch is at least 3:12, the height limit is 14 feet.
g. Pursuant to CMC Section 21.10.080(A)(2)(g)(i), detached accessory structures which are not
dwelling units, contain no habitable space, and are within the primary dwelling's required setback
areas, shall not exceed a building coverage of four hundred forty square feet.
h. Pursuant to CMC Section 21.10.120{A)(4), a minimum roof pitch of 3:20 is required.
i. Pursuant to Table E in CMC Section 21.44.060{A)(4), a driveway located in the front yard setback
(within private property) shall not exceed 24 feet in width or 30 percent of the front yard setback
area, whichever is greater.
4. The existing residential structure appears to be over 50 years in age. A cultural resources report
prepared by the appropriate registered professional is required with the formal application. Please
refer to the City of Carlsbad Tribal, Cultural, and Paleontological Resources Guidelines for further
information. The Guidelines are available for review on the City of Carlsbad website at:
http://www.carlsbadca.gov/civicax/filebank/blobd1oad.aspx?Blob1D=340l0
5. Per the recently approved Housing Crisis Act of 2019 (SB 330), any project that includes the removal
or demolition of a "protected unit" is required to provide the occupants with 1) relocation benefits
(Gov. Code § 7260 et seq.), and 2) right of first refusal for a comparable unit available in the new
housing development. (Gov. Code § 66300 (d)(2)(D).) "Protected units" are generally defined by Gov.
Code § 66300(d)(2)(E)(ii) as including residential units subject to affordability restrictions, price
controls, or occupied by low income households. The formal submittal of the project will need to
include documentation regarding any existing "protected units."
PRE 2020-0003 (DEV2020-0011)-REED FAMILY RESIDENCE
March 2, 2020
Page 3
6. A formal development application submittal will need to include a completed Climate Action Plan
(CAP) Checklist (Form B-50) to determine what requirements will apply to the project. CAP
requirements are related to energy efficiency, photovoltaic, electric vehicle charging, water heating
and traffic demand management requirements, as set forth in the California Green Building Standards
Code and in Carlsbad Municipal Code Chapters 18.21, 18.30 and 18.51 which is available on the city's
website at the following address:
http://www.qcode.us/codes/carlsbad/view.php?topic=18&frames=on
All necessary application forms; submittal requirements, and fee information are available at the Planning
counter located in the Faraday Building at 1635 Faraday Avenue or online at
http:ljwww.carlsbadca.gov/services/depts/planning/default.asp. You may also access the General Plan
Land Use Element and the Zoning Ordinance online at the website address shown; select Department
Listing; select Planning Home Page. Please review all information carefully before submitting.
Land Development Engineering:
1. Complete a Stormwater Standards Questionnaire. This questionnaire will guide you and the City in
determining what type of reports and storm water mitigation must be completed to satisfy state and
City storm water quality requirements. The questionnaire can be printed from the following website
link:
http://www.carlsbadca.gov/civicax/filebank/blobdload.aspx?Blob1D=22711
Preliminary analysis suggests that the project is a Priority Development Project and must comply with
PDP stormwater requirements of the BMP Manual. A Storm Water Quality Management Plan
(SWQMP) must be prepared and submitted at time of application.
2. Reduce the existing 34-foot-wide driveway to a standard 16 feet within the public right-of-way.
3. A preliminary hydrology study will be required to determine the pre-development and post-
development discharge flows. Provide preliminary recommendations to mitigate any increase in
flows.
4. Provide a preliminary Geotechnical study that identifies feasibility and recommendations for the
proposed project including design recommendations for proposed pollutant control BMPs and
hydromodification facilities.
5. A recent Preliminary Title Report (PTR) will be required with formal project application submittal.
6. All easements and encumbrances identified in the PTR must be indicated on the site plan.
7. Show complete property boundary data on the site plan, including bearings and distances.
8. Provide a typical street cross section of Buena Vista Way showing existing improvements.
PRE 2020-0003 (DEV2020-0011) -REED FAMILY RESIDENCE
March 2, 2020
Page 4
9. On the site plan, show and identify all existing surface improvements (curb, gutter, sidewalk, paving,
manholes, inlets, street lights, adjacent driveways, vaults, transformers, etc.) at the project frontage
and within 100 feet.
10. Show existing and proposed contour lines onsite and extend at least 100 feet beyond property lines.
11. Show the locations of all existing and proposed buildings, walls, fences, and permanent structures
onsite and within 100 feet of site.
12. Provide multiple cross-sections of the site to demonstrate differences in grade, including adjacent
properties.
13. Indicate the volume of grading (cut, fill, import, export, remedial) proposed for the project in cubic
yards.
14. Show the location of the proposed BMPs.
15. Show proposed finished floor elevations for structures and pool elevation.
16. Show existing (and proposed if different) water service and sewer lateral.
17. Please be advised that in order to make a more in-depth review of the proposed development, a more
complete design of the project is required.
If you would like to schedule a meeting to discuss this letter with the commenting departments, please
contact Esteban Danna at the number below. You may also contact each department individually as
follows:
• Planning Division: Esteban Danna, Associate Planner, at (760) 602-4629
• Land Development Engineering: Allison Mclaughlin, Associate Engineer, at (760) 602-2732
• Fire Department: Randall Metz, Fire Inspections, at (760) 602-4661
DON NEU, AICP
City Planner
DN:ED:mf
c: Holly and Charlie Reed, 3716 Arapaho Place, Carlsbad, CA 92010
Allison McLaughlin, Project Engineer
Fire Prevention
HPRM/File Copy
Data Entry